CVE-2024-28765 (GCVE-0-2024-28765)

Vulnerability from cvelistv5 – Published: 2026-05-27 13:47 – Updated: 2026-05-28 15:39
VLAI
Title
Security vulnerability was found in IBM Security Directory Integrator
Summary
IBM SDI 7.2.0.0 through 7.2.0.14 and IBM Security Directory Integrator 10.0.0.0 through 10.0.0.2 could allow a remote attacker to obtain sensitive information when a detailed technical error message is returned in the browser. This information could be used in further attacks against the system.
CWE
  • CWE-209 - Generation of Error Message Containing Sensitive Information
Assigner
ibm
References
URL Tags
https://www.ibm.com/support/pages/node/7268903 vendor-advisorypatch
Impacted products
Vendor Product Version
IBM SDI Affected: 7.2.0.0 , ≤ 7.2.0.14 (semver)
    cpe:2.3:a:ibm:sdi:7.2.0.0:*:*:*:*:*:*:*
    cpe:2.3:a:ibm:sdi:7.2.0.14:*:*:*:*:*:*:*
Create a notification for this product.
IBM Security Directory Integrator Affected: 10.0.0.0 , ≤ 10.0.0.2 (semver)
    cpe:2.3:a:ibm:security_directory_integrator:10.0.0.0:*:*:*:*:*:*:*
    cpe:2.3:a:ibm:security_directory_integrator:10.0.0.2:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-28765",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-28T15:39:43.878591Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-28T15:39:51.262Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:a:ibm:sdi:7.2.0.0:*:*:*:*:*:*:*",
            "cpe:2.3:a:ibm:sdi:7.2.0.14:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "SDI",
          "vendor": "IBM",
          "versions": [
            {
              "lessThanOrEqual": "7.2.0.14",
              "status": "affected",
              "version": "7.2.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:ibm:security_directory_integrator:10.0.0.0:*:*:*:*:*:*:*",
            "cpe:2.3:a:ibm:security_directory_integrator:10.0.0.2:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Security Directory Integrator",
          "vendor": "IBM",
          "versions": [
            {
              "lessThanOrEqual": "10.0.0.2",
              "status": "affected",
              "version": "10.0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eIBM SDI 7.2.0.0 through 7.2.0.14 and IBM Security Directory Integrator 10.0.0.0 through 10.0.0.2 could allow a remote attacker to obtain sensitive information when a detailed technical error message is returned in the browser.  This information could be used in further attacks against the system.\u003c/p\u003e"
            }
          ],
          "value": "IBM SDI 7.2.0.0 through 7.2.0.14 and IBM Security Directory Integrator 10.0.0.0 through 10.0.0.2 could allow a remote attacker to obtain sensitive information when a detailed technical error message is returned in the browser.  This information could be used in further attacks against the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-209",
              "description": "CWE-209 Generation of Error Message Containing Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-27T13:51:19.302Z",
        "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
        "shortName": "ibm"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://www.ibm.com/support/pages/node/7268903"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003cstrong\u003eIBM strongly encourages customers to update their systems promptly.\u003c/strong\u003e\u003c/p\u003e\u003cdiv\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003cstrong\u003ePrincipal Product and Versions\u003c/strong\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u003cstrong\u003eFix Availability\u003c/strong\u003e\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eIBM Security Director Integrator 7.2.0.15\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u003ca href=\"https://www.ibm.com/support/fixcentral/swg/selectFixes?parent=IBM%20Security\u0026amp;product=ibm/Tivoli/Security+Directory+Integrator\u0026amp;release=7.2.0.15\u0026amp;platform=All\u0026amp;function=all\" rel=\"nofollow\"\u003e7.2.0-ISS-SDI-FP0015\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eIBM Security Verify Directory Integrator 10.0.0.3\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u003ca href=\"https://www.ibm.com/support/fixcentral/swg/selectFixes?product=ibm%2FTivoli%2FSecurity+Directory+Integrator\u0026amp;fixids=ibm-svdi-10.0.0.3\u0026amp;source=SAR\u0026amp;function=fixId\u0026amp;parent=IBM%20Security\" rel=\"nofollow\"\u003eIBM-SVDI-10.0.0.3\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003c/div\u003e"
            }
          ],
          "value": "IBM strongly encourages customers to update their systems promptly.\n\n\n\nPrincipal Product and Versions\n\n\n\nFix Availability\n\n\n\nIBM Security Director Integrator 7.2.0.15\n\n\n\n 7.2.0-ISS-SDI-FP0015 https://www.ibm.com/support/fixcentral/swg/selectFixes \n\n\n\nIBM Security Verify Directory Integrator 10.0.0.3\n\n\n\n IBM-SVDI-10.0.0.3 https://www.ibm.com/support/fixcentral/swg/selectFixes"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Security vulnerability was found in IBM Security Directory Integrator",
      "x_generator": {
        "engine": "ibm-cvegen"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
    "assignerShortName": "ibm",
    "cveId": "CVE-2024-28765",
    "datePublished": "2026-05-27T13:47:21.877Z",
    "dateReserved": "2024-03-10T12:22:43.138Z",
    "dateUpdated": "2026-05-28T15:39:51.262Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-28765",
      "date": "2026-05-28",
      "epss": "0.00031",
      "percentile": "0.09457"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-28765\",\"sourceIdentifier\":\"psirt@us.ibm.com\",\"published\":\"2026-05-27T14:16:40.600\",\"lastModified\":\"2026-05-27T14:53:51.833\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"IBM SDI 7.2.0.0 through 7.2.0.14 and IBM Security Directory Integrator 10.0.0.0 through 10.0.0.2 could allow a remote attacker to obtain sensitive information when a detailed technical error message is returned in the browser.  This information could be used in further attacks against the system.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@us.ibm.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"psirt@us.ibm.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-209\"}]}],\"references\":[{\"url\":\"https://www.ibm.com/support/pages/node/7268903\",\"source\":\"psirt@us.ibm.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-28765\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-05-28T15:39:43.878591Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-05-28T15:39:47.226Z\"}}], \"cna\": {\"title\": \"Security vulnerability was found in IBM Security Directory Integrator\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:ibm:sdi:7.2.0.0:*:*:*:*:*:*:*\", \"cpe:2.3:a:ibm:sdi:7.2.0.14:*:*:*:*:*:*:*\"], \"vendor\": \"IBM\", \"product\": \"SDI\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.2.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.2.0.14\"}], \"defaultStatus\": \"unaffected\"}, {\"cpes\": [\"cpe:2.3:a:ibm:security_directory_integrator:10.0.0.0:*:*:*:*:*:*:*\", \"cpe:2.3:a:ibm:security_directory_integrator:10.0.0.2:*:*:*:*:*:*:*\"], \"vendor\": \"IBM\", \"product\": \"Security Directory Integrator\", \"versions\": [{\"status\": \"affected\", \"version\": \"10.0.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"10.0.0.2\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"IBM strongly encourages customers to update their systems promptly.\\n\\n\\n\\nPrincipal Product and Versions\\n\\n\\n\\nFix Availability\\n\\n\\n\\nIBM Security Director Integrator 7.2.0.15\\n\\n\\n\\n 7.2.0-ISS-SDI-FP0015 https://www.ibm.com/support/fixcentral/swg/selectFixes \\n\\n\\n\\nIBM Security Verify Directory Integrator 10.0.0.3\\n\\n\\n\\n IBM-SVDI-10.0.0.3 https://www.ibm.com/support/fixcentral/swg/selectFixes\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003e\u003cstrong\u003eIBM strongly encourages customers to update their systems promptly.\u003c/strong\u003e\u003c/p\u003e\u003cdiv\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003cstrong\u003ePrincipal Product and Versions\u003c/strong\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u003cstrong\u003eFix Availability\u003c/strong\u003e\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eIBM Security Director Integrator 7.2.0.15\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u003ca href=\\\"https://www.ibm.com/support/fixcentral/swg/selectFixes?parent=IBM%20Security\u0026amp;product=ibm/Tivoli/Security+Directory+Integrator\u0026amp;release=7.2.0.15\u0026amp;platform=All\u0026amp;function=all\\\" rel=\\\"nofollow\\\"\u003e7.2.0-ISS-SDI-FP0015\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eIBM Security Verify Directory Integrator 10.0.0.3\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u003ca href=\\\"https://www.ibm.com/support/fixcentral/swg/selectFixes?product=ibm%2FTivoli%2FSecurity+Directory+Integrator\u0026amp;fixids=ibm-svdi-10.0.0.3\u0026amp;source=SAR\u0026amp;function=fixId\u0026amp;parent=IBM%20Security\\\" rel=\\\"nofollow\\\"\u003eIBM-SVDI-10.0.0.3\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003c/div\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://www.ibm.com/support/pages/node/7268903\", \"tags\": [\"vendor-advisory\", \"patch\"]}], \"x_generator\": {\"engine\": \"ibm-cvegen\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"IBM SDI 7.2.0.0 through 7.2.0.14 and IBM Security Directory Integrator 10.0.0.0 through 10.0.0.2 could allow a remote attacker to obtain sensitive information when a detailed technical error message is returned in the browser.  This information could be used in further attacks against the system.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eIBM SDI 7.2.0.0 through 7.2.0.14 and IBM Security Directory Integrator 10.0.0.0 through 10.0.0.2 could allow a remote attacker to obtain sensitive information when a detailed technical error message is returned in the browser.  This information could be used in further attacks against the system.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-209\", \"description\": \"CWE-209 Generation of Error Message Containing Sensitive Information\"}]}], \"providerMetadata\": {\"orgId\": \"9a959283-ebb5-44b6-b705-dcc2bbced522\", \"shortName\": \"ibm\", \"dateUpdated\": \"2026-05-27T13:51:19.302Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-28765\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-05-28T15:39:51.262Z\", \"dateReserved\": \"2024-03-10T12:22:43.138Z\", \"assignerOrgId\": \"9a959283-ebb5-44b6-b705-dcc2bbced522\", \"datePublished\": \"2026-05-27T13:47:21.877Z\", \"assignerShortName\": \"ibm\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…