cve-2024-10575
Vulnerability from cvelistv5
Published
2024-11-13 04:35
Modified
2024-11-13 15:14
Summary
CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on the network and potentially impacting connected devices.
Impacted products
Vendor Product Version
Schneider Electric EcoStruxure IT Gateway Version: Version 1.21.0.6
Version: Version 1.22.0.3
Version: Version 1.22.1.5
Version: Version 1.23.0.4
Create a notification for this product.
Show details on NVD website


{
   containers: {
      adp: [
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:-:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "ecostruxure_it_gateway",
                  vendor: "schneider-electric",
                  versions: [
                     {
                        status: "affected",
                        version: "1.21.0.6",
                     },
                     {
                        status: "affected",
                        version: "1.22.0.3",
                     },
                     {
                        status: "affected",
                        version: "1.22.1.5",
                     },
                     {
                        status: "affected",
                        version: "1.23.0.4",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2024-10575",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-11-13T15:14:10.869591Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-11-13T15:14:17.114Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unaffected",
               product: "EcoStruxure IT Gateway",
               vendor: "Schneider Electric",
               versions: [
                  {
                     status: "affected",
                     version: "Version 1.21.0.6",
                  },
                  {
                     status: "affected",
                     version: "Version 1.22.0.3",
                  },
                  {
                     status: "affected",
                     version: "Version 1.22.1.5",
                  },
                  {
                     status: "affected",
                     version: "Version 1.23.0.4",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               supportingMedia: [
                  {
                     base64: false,
                     type: "text/html",
                     value: "CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on\nthe network and potentially impacting connected devices.",
                  },
               ],
               value: "CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on\nthe network and potentially impacting connected devices.",
            },
         ],
         metrics: [
            {
               cvssV4_0: {
                  Automatable: "NOT_DEFINED",
                  Recovery: "NOT_DEFINED",
                  Safety: "NOT_DEFINED",
                  attackComplexity: "LOW",
                  attackRequirements: "NONE",
                  attackVector: "NETWORK",
                  baseScore: 10,
                  baseSeverity: "CRITICAL",
                  privilegesRequired: "NONE",
                  providerUrgency: "NOT_DEFINED",
                  subAvailabilityImpact: "HIGH",
                  subConfidentialityImpact: "HIGH",
                  subIntegrityImpact: "LOW",
                  userInteraction: "NONE",
                  valueDensity: "NOT_DEFINED",
                  vectorString: "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H",
                  version: "4.0",
                  vulnAvailabilityImpact: "HIGH",
                  vulnConfidentialityImpact: "HIGH",
                  vulnIntegrityImpact: "HIGH",
                  vulnerabilityResponseEffort: "NOT_DEFINED",
               },
               format: "CVSS",
               scenarios: [
                  {
                     lang: "en",
                     value: "GENERAL",
                  },
               ],
            },
            {
               cvssV3_1: {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
               format: "CVSS",
               scenarios: [
                  {
                     lang: "en",
                     value: "GENERAL",
                  },
               ],
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-862",
                     description: "CWE-862 Missing Authorization",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-11-13T04:35:44.556Z",
            orgId: "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            shortName: "schneider",
         },
         references: [
            {
               url: "https://download.schneider-electric.com/doc/SEVD-2024-317-04/SEVD-2024-317-04.pdf",
            },
         ],
         source: {
            discovery: "UNKNOWN",
         },
         x_generator: {
            engine: "Vulnogram 0.2.0",
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
      assignerShortName: "schneider",
      cveId: "CVE-2024-10575",
      datePublished: "2024-11-13T04:35:44.556Z",
      dateReserved: "2024-10-31T08:33:14.823Z",
      dateUpdated: "2024-11-13T15:14:17.114Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      nvd: "{\"cve\":{\"id\":\"CVE-2024-10575\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2024-11-13T05:15:11.233\",\"lastModified\":\"2024-11-19T17:28:06.750\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on\\nthe network and potentially impacting connected devices.\"},{\"lang\":\"es\",\"value\":\"CWE-862: Existe una vulnerabilidad de autorización faltante que podría causar acceso no autorizado cuando se habilita en la red y potencialmente afectar los dispositivos conectados.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":10.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"HIGH\",\"vulnerableSystemIntegrity\":\"HIGH\",\"vulnerableSystemAvailability\":\"HIGH\",\"subsequentSystemConfidentiality\":\"HIGH\",\"subsequentSystemIntegrity\":\"LOW\",\"subsequentSystemAvailability\":\"HIGH\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-862\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:1.21.0.6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B416D9C9-F5FE-4837-AD8D-99A02B61F61E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:1.22.0.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"95F485CD-6B41-47EA-9F89-8BF8822893A3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:1.22.1.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6BA248E9-160E-46B5-BE1B-DB2B79D50746\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:1.23.0.4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A6FB2D5E-ACF8-4582-A3C6-E0F099A9442C\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/doc/SEVD-2024-317-04/SEVD-2024-317-04.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}",
      vulnrichment: {
         containers: "{\"cna\": {\"affected\": [{\"defaultStatus\": \"unaffected\", \"product\": \"EcoStruxure IT Gateway\", \"vendor\": \"Schneider Electric\", \"versions\": [{\"status\": \"affected\", \"version\": \"Version 1.21.0.6\"}, {\"status\": \"affected\", \"version\": \"Version 1.22.0.3\"}, {\"status\": \"affected\", \"version\": \"Version 1.22.1.5\"}, {\"status\": \"affected\", \"version\": \"Version 1.23.0.4\"}]}], \"descriptions\": [{\"lang\": \"en\", \"supportingMedia\": [{\"base64\": false, \"type\": \"text/html\", \"value\": \"CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on\\nthe network and potentially impacting connected devices.\"}], \"value\": \"CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on\\nthe network and potentially impacting connected devices.\"}], \"metrics\": [{\"cvssV4_0\": {\"Automatable\": \"NOT_DEFINED\", \"Recovery\": \"NOT_DEFINED\", \"Safety\": \"NOT_DEFINED\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"attackVector\": \"NETWORK\", \"baseScore\": 10, \"baseSeverity\": \"CRITICAL\", \"privilegesRequired\": \"NONE\", \"providerUrgency\": \"NOT_DEFINED\", \"subAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"HIGH\", \"subIntegrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H\", \"version\": \"4.0\", \"vulnAvailabilityImpact\": \"HIGH\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnIntegrityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"format\": \"CVSS\", \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"cvssV3_1\": {\"attackComplexity\": \"LOW\", \"attackVector\": \"NETWORK\", \"availabilityImpact\": \"HIGH\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"scope\": \"UNCHANGED\", \"userInteraction\": \"NONE\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"version\": \"3.1\"}, \"format\": \"CVSS\", \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"problemTypes\": [{\"descriptions\": [{\"cweId\": \"CWE-862\", \"description\": \"CWE-862 Missing Authorization\", \"lang\": \"en\", \"type\": \"CWE\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2024-11-13T04:35:44.556Z\"}, \"references\": [{\"url\": \"https://download.schneider-electric.com/doc/SEVD-2024-317-04/SEVD-2024-317-04.pdf\"}], \"source\": {\"discovery\": \"UNKNOWN\"}, \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}}, \"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-10575\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-13T15:14:10.869591Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:-:*:*:*:*:*:*:*\"], \"vendor\": \"schneider-electric\", \"product\": \"ecostruxure_it_gateway\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.21.0.6\"}, {\"status\": \"affected\", \"version\": \"1.22.0.3\"}, {\"status\": \"affected\", \"version\": \"1.22.1.5\"}, {\"status\": \"affected\", \"version\": \"1.23.0.4\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-13T15:13:26.830Z\"}}]}",
         cveMetadata: "{\"cveId\": \"CVE-2024-10575\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"schneider\", \"dateReserved\": \"2024-10-31T08:33:14.823Z\", \"datePublished\": \"2024-11-13T04:35:44.556Z\", \"dateUpdated\": \"2024-11-13T15:14:17.114Z\"}",
         dataType: "CVE_RECORD",
         dataVersion: "5.1",
      },
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.