CVE-2023-29411 (GCVE-0-2023-29411)
Vulnerability from cvelistv5 – Published: 2023-04-18 20:49 – Updated: 2025-02-05 21:22- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022) |
Affected:
V2.5-GA-01-22320 , ≤ prior
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.023Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29411",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T21:21:55.206695Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T21:22:08.895Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GA-01-22320",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GS-01-22320",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-11T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n"
}
],
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-18T20:49:34.059Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-29411",
"datePublished": "2023-04-18T20:49:34.059Z",
"dateReserved": "2023-04-05T20:35:41.367Z",
"dateUpdated": "2025-02-05T21:22:08.895Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"2.5-ga-01-22320\", \"matchCriteriaId\": \"D52617D6-0503-4B6B-A59D-441E0D1F4296\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"21540673-614A-4D40-8BD7-3F07723803B0\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\", \"matchCriteriaId\": \"647F2145-B063-43EA-8045-32D3B4D893F6\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DB79EE26-FC32-417D-A49C-A1A63165A968\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"2.5-gs-01-22320\", \"matchCriteriaId\": \"1849E03C-445A-4225-AECD-B4A7502F5F3B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"21540673-614A-4D40-8BD7-3F07723803B0\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\", \"matchCriteriaId\": \"647F2145-B063-43EA-8045-32D3B4D893F6\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DB79EE26-FC32-417D-A49C-A1A63165A968\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"\\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\\nchanges to administrative credentials, leading to potential remote code execution without\\nrequiring prior authentication on the Java RMI interface. \\n\\n\\n\\n\"}]",
"id": "CVE-2023-29411",
"lastModified": "2024-11-21T07:57:00.540",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
"published": "2023-04-18T21:15:09.390",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Mitigation\", \"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Patch\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-29411\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-04-18T21:15:09.390\",\"lastModified\":\"2024-11-21T07:57:00.540\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\\nchanges to administrative credentials, leading to potential remote code execution without\\nrequiring prior authentication on the Java RMI interface. \\n\\n\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5-ga-01-22320\",\"matchCriteriaId\":\"D52617D6-0503-4B6B-A59D-441E0D1F4296\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"21540673-614A-4D40-8BD7-3F07723803B0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"647F2145-B063-43EA-8045-32D3B4D893F6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB79EE26-FC32-417D-A49C-A1A63165A968\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5-gs-01-22320\",\"matchCriteriaId\":\"1849E03C-445A-4225-AECD-B4A7502F5F3B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"21540673-614A-4D40-8BD7-3F07723803B0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"647F2145-B063-43EA-8045-32D3B4D893F6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB79EE26-FC32-417D-A49C-A1A63165A968\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T14:07:46.023Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-29411\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-05T21:21:55.206695Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-05T21:22:01.714Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V2.5-GA-01-22320\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"prior\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V2.5-GS-01-22320\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"prior\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2023-04-11T07:00:00.000Z\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\\nchanges to administrative credentials, leading to potential remote code execution without\\nrequiring prior authentication on the Java RMI interface. \\n\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\\nchanges to administrative credentials, leading to potential remote code execution without\\nrequiring prior authentication on the Java RMI interface. \\n\\n\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306 Missing Authentication for Critical Function\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2023-04-18T20:49:34.059Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-29411\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-05T21:22:08.895Z\", \"dateReserved\": \"2023-04-05T20:35:41.367Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2023-04-18T20:49:34.059Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
ICSA-23-108-02
Vulnerability from csaf_cisa - Published: 2023-04-18 06:00 - Updated: 2024-06-11 06:00Notes
{
"document": {
"acknowledgments": [
{
"names": [
"Esjay"
],
"organization": "Trend Micro Zero Day Initiative",
"summary": "reporting these vulnerabilities to Schneider Electric and CISA"
},
{
"names": [
"Nicholas Miles"
],
"organization": "Tenable",
"summary": "reporting these vulnerabilities to Schneider Electric and CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could result in an attacker achieving remote code execution on the underlying operating system when manipulating internal methods through the Java RMI interface. It could also result in escalation of privileges or authentication bypass, which could then result in malicious web code execution or loss of device functionality.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-23-108-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-108-02.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-23-108-02 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-108-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
}
],
"title": "Schneider Electric APC Easy UPS Online Monitoring Software (Update A)",
"tracking": {
"current_release_date": "2024-06-11T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-108-02",
"initial_release_date": "2023-04-18T06:00:00.000000Z",
"revision_history": [
{
"date": "2023-04-18T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
},
{
"date": "2024-06-11T06:00:00.000000Z",
"legacy_version": "Update A",
"number": "2",
"summary": "Update A - Updated CVE-2023-29412, mitigations section, and affected product version for APC version of product to reflect publicly available exploit found by Schneider."
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=v2.5-GA-01-22261",
"product": {
"name": "Schneider Electric APC Easy UPS Online Monitoring Software: \u003c=v2.5-GA-01-22261",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "APC Easy UPS Online Monitoring Software"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=V2.5-GA-01-22320",
"product": {
"name": "Schneider Electric Schneider Electric Easy UPS Online Monitoring Software: \u003c=V2.5-GA-01-22320",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Schneider Electric Easy UPS Online Monitoring Software"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-29411",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-29411"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Schneider Electric became aware of a public PoC detailing an exploit for prior versions of the APC Easy UPS Online Monitoring Software, and strongly recommends all users take the defensive actions listed in this advisory.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "The affected software is being discontinued with the discontinuation of the Easy UPS Online SNMP Cards (APV9601, APVS9601) managed by this software. Fixed versions notwithstanding, Schneider Electric recommends users to migrate to the PowerChute series of software, including PowerChute Serial Shutdown and PowerChute Network Shutdown. For more information, please see the following sites:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "PowerChute Serial Shutdown",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.apc.com/pcss"
},
{
"category": "mitigation",
"details": "PowerChute Network Shutdown",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.apc.com/pcns"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends users update their affected devices to the following versions or later:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "APC Easy UPS Online Monitoring Software: Version 2.6-GA or later",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Software+-+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows"
},
{
"category": "vendor_fix",
"details": "Schneider Electric Easy UPS Online Monitoring Software: Version 2.6-GS or later",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Software+-+Release\u0026p_Doc_Ref=Install_Schneider_UPS_windows"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends that users use appropriate patching methodologies when applying these patches to their systems and impact evaluate these patches in a test, development, or offline infrastructure environment. Schneider Electric strongly recommends the use of backups.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Users can contact Schneider Electric\u0027s Customer Care Center for additional assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends users follow cybersecurity industry best practices, including:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Locating control and safety system networks and remote devices behind firewalls and isolating them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Installing physical controls to help prevent unauthorized users from accessing industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Placing all controllers in locked cabinets, and do not leave them in the \"Program\" mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Only connecting programming software to the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Scanning all methods of mobile data exchange with the isolated network before use in the terminals or nodes connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Properly sanitizing mobile devices that have connected to another network before connecting to the intended network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Minimizing network exposure for all control system devices and systems and ensure that they are not accessible from the internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Using secure methods, such as virtual private networks (VPNs), when remote access is required.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "For more information, refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "mitigation",
"details": "For more information, see Schneider Electric security notification SEVD-2023-101-04",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2023-29412",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Prior versions of Schneider Electric APC Easy UPS Online contain an OS Command Injection vulnerability that could cause remote code execution when manipulating internal methods through Java RMI interface.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-29412"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Schneider Electric became aware of a public PoC detailing an exploit for prior versions of the APC Easy UPS Online Monitoring Software, and strongly recommends all users take the defensive actions listed in this advisory.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "The affected software is being discontinued with the discontinuation of the Easy UPS Online SNMP Cards (APV9601, APVS9601) managed by this software. Fixed versions notwithstanding, Schneider Electric recommends users to migrate to the PowerChute series of software, including PowerChute Serial Shutdown and PowerChute Network Shutdown. For more information, please see the following sites:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "PowerChute Serial Shutdown",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.apc.com/pcss"
},
{
"category": "mitigation",
"details": "PowerChute Network Shutdown",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.apc.com/pcns"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends users update their affected devices to the following versions or later:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "APC Easy UPS Online Monitoring Software: Version 2.6-GA or later",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Software+-+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows"
},
{
"category": "vendor_fix",
"details": "Schneider Electric Easy UPS Online Monitoring Software: Version 2.6-GS or later",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Software+-+Release\u0026p_Doc_Ref=Install_Schneider_UPS_windows"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends that users use appropriate patching methodologies when applying these patches to their systems and impact evaluate these patches in a test, development, or offline infrastructure environment. Schneider Electric strongly recommends the use of backups.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Users can contact Schneider Electric\u0027s Customer Care Center for additional assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends users follow cybersecurity industry best practices, including:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Locating control and safety system networks and remote devices behind firewalls and isolating them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Installing physical controls to help prevent unauthorized users from accessing industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Placing all controllers in locked cabinets, and do not leave them in the \"Program\" mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Only connecting programming software to the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Scanning all methods of mobile data exchange with the isolated network before use in the terminals or nodes connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Properly sanitizing mobile devices that have connected to another network before connecting to the intended network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Minimizing network exposure for all control system devices and systems and ensure that they are not accessible from the internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Using secure methods, such as virtual private networks (VPNs), when remote access is required.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "For more information, refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "mitigation",
"details": "For more information, see Schneider Electric security notification SEVD-2023-101-04",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2023-29413",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability exists that could cause a denial-of-service condition when accessed by an unauthenticated user on the Schneider UPS Monitor service. ",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-29413"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Schneider Electric became aware of a public PoC detailing an exploit for prior versions of the APC Easy UPS Online Monitoring Software, and strongly recommends all users take the defensive actions listed in this advisory.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "The affected software is being discontinued with the discontinuation of the Easy UPS Online SNMP Cards (APV9601, APVS9601) managed by this software. Fixed versions notwithstanding, Schneider Electric recommends users to migrate to the PowerChute series of software, including PowerChute Serial Shutdown and PowerChute Network Shutdown. For more information, please see the following sites:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "PowerChute Serial Shutdown",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.apc.com/pcss"
},
{
"category": "mitigation",
"details": "PowerChute Network Shutdown",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.apc.com/pcns"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends users update their affected devices to the following versions or later:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "APC Easy UPS Online Monitoring Software: Version 2.6-GA or later",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Software+-+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows"
},
{
"category": "vendor_fix",
"details": "Schneider Electric Easy UPS Online Monitoring Software: Version 2.6-GS or later",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_enDocType=Software+-+Release\u0026p_Doc_Ref=Install_Schneider_UPS_windows"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends that users use appropriate patching methodologies when applying these patches to their systems and impact evaluate these patches in a test, development, or offline infrastructure environment. Schneider Electric strongly recommends the use of backups.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Users can contact Schneider Electric\u0027s Customer Care Center for additional assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Schneider Electric strongly recommends users follow cybersecurity industry best practices, including:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Locating control and safety system networks and remote devices behind firewalls and isolating them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Installing physical controls to help prevent unauthorized users from accessing industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Placing all controllers in locked cabinets, and do not leave them in the \"Program\" mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Only connecting programming software to the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Scanning all methods of mobile data exchange with the isolated network before use in the terminals or nodes connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Properly sanitizing mobile devices that have connected to another network before connecting to the intended network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Minimizing network exposure for all control system devices and systems and ensure that they are not accessible from the internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Using secure methods, such as virtual private networks (VPNs), when remote access is required.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "For more information, refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "mitigation",
"details": "For more information, see Schneider Electric security notification SEVD-2023-101-04",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
CNVD-2023-40175
Vulnerability from cnvd - Published: 2023-05-24厂商已发布了漏洞修复程序,请及时关注更新: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-04.pdf
| Name | Schneider Electric Schneider Electric Easy UPS Online Monitoring Software <=V2.5-GA-01-22320 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2023-29411",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2023-29411"
}
},
"description": "Schneider Electric Easy UPS Online Monitoring Software\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u7535\u6e90\u76d1\u63a7\u8f6f\u4ef6\u3002\n\nSchneider Electric Easy UPS Online Monitoring Software\u5b58\u5728\u8bbf\u95ee\u63a7\u5236\u9519\u8bef\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u7f3a\u5c11\u5173\u952e\u529f\u80fd\u7684\u8eab\u4efd\u9a8c\u8bc1\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u6f5c\u5728\u7684\u8fdc\u7a0b\u4ee3\u7801\u6267\u884c\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2023-40175",
"openTime": "2023-05-24",
"patchDescription": "Schneider Electric Easy UPS Online Monitoring Software\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u7535\u6e90\u76d1\u63a7\u8f6f\u4ef6\u3002\r\n\r\nSchneider Electric Easy UPS Online Monitoring Software\u5b58\u5728\u8bbf\u95ee\u63a7\u5236\u9519\u8bef\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u7f3a\u5c11\u5173\u952e\u529f\u80fd\u7684\u8eab\u4efd\u9a8c\u8bc1\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u6f5c\u5728\u7684\u8fdc\u7a0b\u4ee3\u7801\u6267\u884c\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric Easy UPS Online Monitoring Software\u8bbf\u95ee\u63a7\u5236\u9519\u8bef\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Schneider Electric Schneider Electric Easy UPS Online Monitoring Software \u003c=V2.5-GA-01-22320"
},
"referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2023-29411",
"serverity": "\u9ad8",
"submitTime": "2023-04-21",
"title": "Schneider Electric Easy UPS Online Monitoring Software\u8bbf\u95ee\u63a7\u5236\u9519\u8bef\u6f0f\u6d1e"
}
CERTFR-2023-AVI-0452
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à la confidentialité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | APC Easy UPS Online Monitoring Software Windows 10, 11, Windows Server 2016, 2019 et 2022 versions antérieures à 2.6-GA-01-23116 | ||
| Schneider Electric | N/A | Schneider Electric Easy UPS Online Monitoring Software Windows 10, 11, Windows Server 2016, 2019 et 2022 versions antérieures à 2.6-GA-01-23116 | ||
| Schneider Electric | N/A | Foxboro SCADA toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Foxboro DCS Control Core Services toutes versions sans le correctif HF9857795 | ||
| Schneider Electric | N/A | IGSS Dashboard versions antérieures à 16.0.0.23131 | ||
| Schneider Electric | N/A | EcoStruxure Operation Terminal Expert versions antérieures à 3.4 | ||
| Schneider Electric | N/A | Pro-face BLUE versions antérieures à 3.4 |
| Title | Publication Time | Tags | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "APC Easy UPS Online Monitoring Software Windows 10, 11, Windows Server 2016, 2019 et 2022 versions ant\u00e9rieures \u00e0 2.6-GA-01-23116",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Easy UPS Online Monitoring Software Windows 10, 11, Windows Server 2016, 2019 et 2022 versions ant\u00e9rieures \u00e0 2.6-GA-01-23116",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Foxboro SCADA toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Foxboro DCS Control Core Services toutes versions sans le correctif HF9857795",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Dashboard versions ant\u00e9rieures \u00e0 16.0.0.23131",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Operation Terminal Expert versions ant\u00e9rieures \u00e0 3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face BLUE versions ant\u00e9rieures \u00e0 3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-29413",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29413"
},
{
"name": "CVE-2023-1049",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1049"
},
{
"name": "CVE-2023-29412",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29412"
},
{
"name": "CVE-2023-3001",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3001"
},
{
"name": "CVE-2023-29411",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29411"
},
{
"name": "CVE-2023-2569",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2569"
},
{
"name": "CVE-2023-2570",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2570"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0452",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-06-13T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-164-02 du 13 juin 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-02.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-04 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-164-01 du 13 juin 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-01.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-164-04 du 13 juin 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-04.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-164-03 du 13 juin 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-03.pdf"
}
]
}
CERTFR-2023-AVI-0297
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Modicon M580 NOC Control (BMENOC0321) versions antérieures à 1.8 | ||
| Schneider Electric | N/A | PacDrive 3 Controllers LMC | ||
| Schneider Electric | N/A | Easergy Builder installer versions antérieures à V1.7.24 | ||
| Schneider Electric | N/A | Modicon Controller LMC058 | ||
| Schneider Electric | N/A | Modicon Controller M258 | ||
| Schneider Electric | N/A | Eco/Pro/Pro2 | ||
| Schneider Electric | N/A | Modicon M580 versions antérieures à SV4.10 | ||
| Schneider Electric | Modicon M340 | Modicon Modicon M340 CPU (part numbers BMXP34*) versions antérieures à SV3.51 | ||
| Schneider Electric | N/A | Modicon Controller M262 | ||
| Schneider Electric | N/A | PacDrive Controller LMC078 | ||
| Schneider Electric | N/A | Modicon Controller M241 | ||
| Schneider Electric | N/A | InsightHome, InsightFacility et Conext Gateway versions antérieures à 1.17 Build 079 | ||
| Schneider Electric | N/A | EcoStruxure Control Expert versions antérieures à V15.3 | ||
| Schneider Electric | N/A | Schneider Electric Easy UPS Online versions antérieures à 2.6-GS | ||
| Schneider Electric | N/A | Modicon Controller M218 | ||
| Schneider Electric | N/A | HMISCU Controller | ||
| Schneider Electric | N/A | Modicon Controller M251 | ||
| Schneider Electric | N/A | Easy Harmony ET6 (HMIET Series) et Easy Harmony GXU (HMIGXU Series) avec Vijeo Designer Basic versions antérieures à V1.2.1 Hotfix 4 | ||
| Schneider Electric | N/A | APC Easy UPS Online Monitoring versions antérieures à 2.6-GA | ||
| Schneider Electric | N/A | Modicon M580 Ethernet Communication Modules (BMENOC0301 et BMENOC0311) versions antérieures à SV2.21 | ||
| Schneider Electric | Modicon M340 | Modicon M340 CPU versions antérieures à SV3.51 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Modicon M580 NOC Control (BMENOC0321) versions ant\u00e9rieures \u00e0 1.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PacDrive 3 Controllers LMC",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easergy Builder installer versions ant\u00e9rieures \u00e0 V1.7.24",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller LMC058",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M258",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Eco/Pro/Pro2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 versions ant\u00e9rieures \u00e0 SV4.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Modicon M340 CPU (part numbers BMXP34*) versions ant\u00e9rieures \u00e0 SV3.51",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M262",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PacDrive Controller LMC078",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M241",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "InsightHome, InsightFacility et Conext Gateway versions ant\u00e9rieures \u00e0 1.17 Build 079",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Control Expert versions ant\u00e9rieures \u00e0 V15.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Easy UPS Online versions ant\u00e9rieures \u00e0 2.6-GS",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M218",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "HMISCU Controller",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M251",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easy Harmony ET6 (HMIET Series) et Easy Harmony GXU (HMIGXU Series) avec Vijeo Designer Basic versions ant\u00e9rieures \u00e0 V1.2.1 Hotfix 4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "APC Easy UPS Online Monitoring versions ant\u00e9rieures \u00e0 2.6-GA",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 Ethernet Communication Modules (BMENOC0301 et BMENOC0311) versions ant\u00e9rieures \u00e0 SV2.21",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 CPU versions ant\u00e9rieures \u00e0 SV3.51",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-29413",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29413"
},
{
"name": "CVE-2023-29410",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29410"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-4046",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4046"
},
{
"name": "CVE-2023-29412",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29412"
},
{
"name": "CVE-2023-27976",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27976"
},
{
"name": "CVE-2022-34755",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34755"
},
{
"name": "CVE-2023-25620",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-25620"
},
{
"name": "CVE-2023-1548",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1548"
},
{
"name": "CVE-2023-29411",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29411"
},
{
"name": "CVE-2023-28355",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28355"
},
{
"name": "CVE-2023-25619",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-25619"
},
{
"name": "CVE-2022-45788",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-45788"
},
{
"name": "CVE-2022-4224",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4224"
},
{
"name": "CVE-2021-29241",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29241"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0297",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-04-11T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-011-06 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-011-06_CODESYSV3_Runtime_Development_System_and_Gateway_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-05 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-06 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-06.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-04 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-02 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-02.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-03 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-03.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-01 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-01.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-010-05 du 10 janvier 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-05_Modicon_Controllers_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_BadAlloc_Vulnerabilities_Security_Notification.pdf"
}
]
}
CERTFR-2023-AVI-0452
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à la confidentialité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | APC Easy UPS Online Monitoring Software Windows 10, 11, Windows Server 2016, 2019 et 2022 versions antérieures à 2.6-GA-01-23116 | ||
| Schneider Electric | N/A | Schneider Electric Easy UPS Online Monitoring Software Windows 10, 11, Windows Server 2016, 2019 et 2022 versions antérieures à 2.6-GA-01-23116 | ||
| Schneider Electric | N/A | Foxboro SCADA toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Foxboro DCS Control Core Services toutes versions sans le correctif HF9857795 | ||
| Schneider Electric | N/A | IGSS Dashboard versions antérieures à 16.0.0.23131 | ||
| Schneider Electric | N/A | EcoStruxure Operation Terminal Expert versions antérieures à 3.4 | ||
| Schneider Electric | N/A | Pro-face BLUE versions antérieures à 3.4 |
| Title | Publication Time | Tags | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "APC Easy UPS Online Monitoring Software Windows 10, 11, Windows Server 2016, 2019 et 2022 versions ant\u00e9rieures \u00e0 2.6-GA-01-23116",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Easy UPS Online Monitoring Software Windows 10, 11, Windows Server 2016, 2019 et 2022 versions ant\u00e9rieures \u00e0 2.6-GA-01-23116",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Foxboro SCADA toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Foxboro DCS Control Core Services toutes versions sans le correctif HF9857795",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Dashboard versions ant\u00e9rieures \u00e0 16.0.0.23131",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Operation Terminal Expert versions ant\u00e9rieures \u00e0 3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face BLUE versions ant\u00e9rieures \u00e0 3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-29413",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29413"
},
{
"name": "CVE-2023-1049",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1049"
},
{
"name": "CVE-2023-29412",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29412"
},
{
"name": "CVE-2023-3001",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3001"
},
{
"name": "CVE-2023-29411",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29411"
},
{
"name": "CVE-2023-2569",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2569"
},
{
"name": "CVE-2023-2570",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2570"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0452",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-06-13T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-164-02 du 13 juin 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-02.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-04 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-164-01 du 13 juin 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-01.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-164-04 du 13 juin 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-04.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-164-03 du 13 juin 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-03.pdf"
}
]
}
CERTFR-2023-AVI-0297
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Modicon M580 NOC Control (BMENOC0321) versions antérieures à 1.8 | ||
| Schneider Electric | N/A | PacDrive 3 Controllers LMC | ||
| Schneider Electric | N/A | Easergy Builder installer versions antérieures à V1.7.24 | ||
| Schneider Electric | N/A | Modicon Controller LMC058 | ||
| Schneider Electric | N/A | Modicon Controller M258 | ||
| Schneider Electric | N/A | Eco/Pro/Pro2 | ||
| Schneider Electric | N/A | Modicon M580 versions antérieures à SV4.10 | ||
| Schneider Electric | Modicon M340 | Modicon Modicon M340 CPU (part numbers BMXP34*) versions antérieures à SV3.51 | ||
| Schneider Electric | N/A | Modicon Controller M262 | ||
| Schneider Electric | N/A | PacDrive Controller LMC078 | ||
| Schneider Electric | N/A | Modicon Controller M241 | ||
| Schneider Electric | N/A | InsightHome, InsightFacility et Conext Gateway versions antérieures à 1.17 Build 079 | ||
| Schneider Electric | N/A | EcoStruxure Control Expert versions antérieures à V15.3 | ||
| Schneider Electric | N/A | Schneider Electric Easy UPS Online versions antérieures à 2.6-GS | ||
| Schneider Electric | N/A | Modicon Controller M218 | ||
| Schneider Electric | N/A | HMISCU Controller | ||
| Schneider Electric | N/A | Modicon Controller M251 | ||
| Schneider Electric | N/A | Easy Harmony ET6 (HMIET Series) et Easy Harmony GXU (HMIGXU Series) avec Vijeo Designer Basic versions antérieures à V1.2.1 Hotfix 4 | ||
| Schneider Electric | N/A | APC Easy UPS Online Monitoring versions antérieures à 2.6-GA | ||
| Schneider Electric | N/A | Modicon M580 Ethernet Communication Modules (BMENOC0301 et BMENOC0311) versions antérieures à SV2.21 | ||
| Schneider Electric | Modicon M340 | Modicon M340 CPU versions antérieures à SV3.51 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Modicon M580 NOC Control (BMENOC0321) versions ant\u00e9rieures \u00e0 1.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PacDrive 3 Controllers LMC",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easergy Builder installer versions ant\u00e9rieures \u00e0 V1.7.24",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller LMC058",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M258",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Eco/Pro/Pro2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 versions ant\u00e9rieures \u00e0 SV4.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Modicon M340 CPU (part numbers BMXP34*) versions ant\u00e9rieures \u00e0 SV3.51",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M262",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PacDrive Controller LMC078",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M241",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "InsightHome, InsightFacility et Conext Gateway versions ant\u00e9rieures \u00e0 1.17 Build 079",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Control Expert versions ant\u00e9rieures \u00e0 V15.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Easy UPS Online versions ant\u00e9rieures \u00e0 2.6-GS",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M218",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "HMISCU Controller",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Controller M251",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easy Harmony ET6 (HMIET Series) et Easy Harmony GXU (HMIGXU Series) avec Vijeo Designer Basic versions ant\u00e9rieures \u00e0 V1.2.1 Hotfix 4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "APC Easy UPS Online Monitoring versions ant\u00e9rieures \u00e0 2.6-GA",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 Ethernet Communication Modules (BMENOC0301 et BMENOC0311) versions ant\u00e9rieures \u00e0 SV2.21",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 CPU versions ant\u00e9rieures \u00e0 SV3.51",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-29413",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29413"
},
{
"name": "CVE-2023-29410",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29410"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-4046",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4046"
},
{
"name": "CVE-2023-29412",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29412"
},
{
"name": "CVE-2023-27976",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27976"
},
{
"name": "CVE-2022-34755",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34755"
},
{
"name": "CVE-2023-25620",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-25620"
},
{
"name": "CVE-2023-1548",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1548"
},
{
"name": "CVE-2023-29411",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29411"
},
{
"name": "CVE-2023-28355",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28355"
},
{
"name": "CVE-2023-25619",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-25619"
},
{
"name": "CVE-2022-45788",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-45788"
},
{
"name": "CVE-2022-4224",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4224"
},
{
"name": "CVE-2021-29241",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29241"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0297",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-04-11T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2022-011-06 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-011-06_CODESYSV3_Runtime_Development_System_and_Gateway_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-05 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-05.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-06 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-06.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-04 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-02 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-02.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-03 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-03.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-101-01 du 11 avril 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-01.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-010-05 du 10 janvier 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-05_Modicon_Controllers_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_BadAlloc_Vulnerabilities_Security_Notification.pdf"
}
]
}
GSD-2023-29411
Vulnerability from gsd - Updated: 2023-12-13 01:20{
"GSD": {
"alias": "CVE-2023-29411",
"id": "GSD-2023-29411"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-29411"
],
"details": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n",
"id": "GSD-2023-29411",
"modified": "2023-12-13T01:20:56.927418Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2023-29411",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "V2.5-GA-01-22320",
"version_value": "prior"
}
]
}
},
{
"product_name": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "V2.5-GS-01-22320",
"version_value": "prior"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-306",
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.5-ga-01-22320",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.5-gs-01-22320",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2023-29411"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf",
"refsource": "MISC",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2023-04-28T13:31Z",
"publishedDate": "2023-04-18T21:15Z"
}
}
}
GHSA-QQ2V-QM3V-4375
Vulnerability from github – Published: 2023-04-18 21:30 – Updated: 2024-04-04 03:34A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.
{
"affected": [],
"aliases": [
"CVE-2023-29411"
],
"database_specific": {
"cwe_ids": [
"CWE-306"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-04-18T21:15:09Z",
"severity": "CRITICAL"
},
"details": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n",
"id": "GHSA-qq2v-qm3v-4375",
"modified": "2024-04-04T03:34:40Z",
"published": "2023-04-18T21:30:30Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-29411"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
FKIE_CVE-2023-29411
Vulnerability from fkie_nvd - Published: 2023-04-18 21:15 - Updated: 2024-11-21 07:579.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D52617D6-0503-4B6B-A59D-441E0D1F4296",
"versionEndIncluding": "2.5-ga-01-22320",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1849E03C-445A-4225-AECD-B4A7502F5F3B",
"versionEndIncluding": "2.5-gs-01-22320",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n"
}
],
"id": "CVE-2023-29411",
"lastModified": "2024-11-21T07:57:00.540",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-04-18T21:15:09.390",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2023-29411
Vulnerability from csaf_se - Published: 2023-04-11 14:09 - Updated: 2024-06-11 00:00Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "The severity of vulnerabilities was calculated using the CVSS Base metrics in version 3.1 (CVSS v3.1) without incorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as the presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a customer\u2019s environment",
"title": "Note regarding vulnerability details"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its Easy UPS Online Monitoring Software, known as APC Easy UPS Online Monitoring Software, and Schneider Electric UPS Online Monitoring Software known as Schneider SP Series UPS Online Monitoring Software in China.\n\nThe Easy UPS Online Monitoring Software is used to configure and manage Easy UPS products.\n\nFailure to apply the remediations provided below may risk remote code execution, escalation of privileges, or authentication bypass, which could result in execution of malicious web code or loss of device functionality.\n\nJune 2024 Update: Vulnerability description for CVE-2023-29412 has been updated. CWE-78 is correct, but the initial description didn\u2019t match with this CWE ID. Remediation instructions were updated to clarify support status.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Easy UPS Online Monitoring Software - SEVD-2023-101-04 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
},
{
"category": "self",
"summary": "Easy UPS Online Monitoring Software - SEVD-2023-101-04 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2023-101-04.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "Easy UPS Online Monitoring Software",
"tracking": {
"current_release_date": "2024-06-11T00:00:00.000Z",
"generator": {
"date": "2024-06-11T00:00:00.000Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2023-101-04",
"initial_release_date": "2023-04-11T14:09:13.000Z",
"revision_history": [
{
"date": "2023-04-11T14:09:13.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2023-04-19T14:09:00.000Z",
"number": "2.0.0",
"summary": "The document has been updated to reflect the APC Easy UPS Online Monitoring Software and Schneider Electric Easy UPS Online Monitoring Software remediation is for Windows 10 only. A mitigation for APC Easy UPS Online Monitoring Software and Schneider Electric Easy UPS Online Monitoring Software for Windows 10, 11 Windows Server 2016, 2019, and 2022 has been added."
},
{
"date": "2023-06-13T14:09:00.000Z",
"number": "3.0.0",
"summary": "A remediation is available that now includes all supported Windows versions."
},
{
"date": "2024-06-11T00:00:00.000Z",
"number": "4.0.0",
"summary": "Vulnerability description for CVE-2023-29412 has been updated. CWE-78 is correct, but the initial description didn\u0027t match with this CWE ID.Remediation instructions were updated to clarify support status."
}
],
"status": "final",
"version": "4.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2.5-GA-01-22320",
"product": {
"name": "APC Easy UPS Online Monitoring Software version 2.5-GA-01-22320 and prior",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Easy UPS Online Monitoring Software"
}
],
"category": "vendor",
"name": "APC"
},
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2.5-GS-01-22320",
"product": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.5-GS-01-22320 and prior",
"product_id": "2"
}
},
{
"category": "product_version",
"name": "2.6-GA-01-23116",
"product": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.6-GA-01-23116",
"product_id": "3"
}
},
{
"category": "product_version",
"name": "2.6-GS-01-23116",
"product": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.6-GS-01-23116",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Easy UPS Online Monitoring Software"
}
],
"category": "vendor",
"name": "Schneider Electric"
},
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "10",
"product": {
"name": "Microsoft Windows 10",
"product_id": "5"
}
},
{
"category": "product_version",
"name": "11",
"product": {
"name": "Microsoft Windows 11",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Windows"
},
{
"branches": [
{
"category": "product_version",
"name": "2016",
"product": {
"name": "Microsoft Windows Server 2016",
"product_id": "7"
}
},
{
"category": "product_version",
"name": "2019",
"product": {
"name": "Microsoft Windows Server 2019",
"product_id": "8"
}
},
{
"category": "product_version",
"name": "2022",
"product": {
"name": "Microsoft Windows Server 2022",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "Windows Server"
}
],
"category": "vendor",
"name": "Microsoft"
}
],
"relationships": [
{
"category": "installed_on",
"full_product_name": {
"name": "APC Easy UPS Online Monitoring Software version 2.5-GA-01-22320 and prior installed on Microsoft Windows 10",
"product_id": "10"
},
"product_reference": "1",
"relates_to_product_reference": "5"
},
{
"category": "installed_on",
"full_product_name": {
"name": "APC Easy UPS Online Monitoring Software version 2.5-GA-01-22320 and prior installed on Microsoft Windows 11",
"product_id": "11"
},
"product_reference": "1",
"relates_to_product_reference": "6"
},
{
"category": "installed_on",
"full_product_name": {
"name": "APC Easy UPS Online Monitoring Software version 2.5-GA-01-22320 and prior installed on Microsoft Windows Server 2016",
"product_id": "12"
},
"product_reference": "1",
"relates_to_product_reference": "7"
},
{
"category": "installed_on",
"full_product_name": {
"name": "APC Easy UPS Online Monitoring Software version 2.5-GA-01-22320 and prior installed on Microsoft Windows Server 2019",
"product_id": "13"
},
"product_reference": "1",
"relates_to_product_reference": "8"
},
{
"category": "installed_on",
"full_product_name": {
"name": "APC Easy UPS Online Monitoring Software version 2.5-GA-01-22320 and prior installed on Microsoft Windows Server 2022",
"product_id": "14"
},
"product_reference": "1",
"relates_to_product_reference": "9"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.5-GS-01-22320 and prior installed on Microsoft Windows 10",
"product_id": "15"
},
"product_reference": "2",
"relates_to_product_reference": "5"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.5-GS-01-22320 and prior installed on Microsoft Windows 11",
"product_id": "16"
},
"product_reference": "2",
"relates_to_product_reference": "6"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.5-GS-01-22320 and prior installed on Microsoft Windows Server 2016",
"product_id": "17"
},
"product_reference": "2",
"relates_to_product_reference": "7"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.5-GS-01-22320 and prior installed on Microsoft Windows Server 2019",
"product_id": "18"
},
"product_reference": "2",
"relates_to_product_reference": "8"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.5-GS-01-22320 and prior installed on Microsoft Windows Server 2022",
"product_id": "19"
},
"product_reference": "2",
"relates_to_product_reference": "9"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.6-GA-01-23116 installed on Microsoft Windows 10",
"product_id": "20"
},
"product_reference": "3",
"relates_to_product_reference": "5"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.6-GA-01-23116 installed on Microsoft Windows 11",
"product_id": "21"
},
"product_reference": "3",
"relates_to_product_reference": "6"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.6-GA-01-23116 installed on Microsoft Windows Server 2016",
"product_id": "22"
},
"product_reference": "3",
"relates_to_product_reference": "7"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.6-GA-01-23116 installed on Microsoft Windows Server 2019",
"product_id": "23"
},
"product_reference": "3",
"relates_to_product_reference": "8"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.6-GA-01-23116 installed on Microsoft Windows Server 2022",
"product_id": "24"
},
"product_reference": "3",
"relates_to_product_reference": "9"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.6-GS-01-23116 installed on Microsoft Windows 10",
"product_id": "25"
},
"product_reference": "4",
"relates_to_product_reference": "5"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.6-GS-01-23116 installed on Microsoft Windows 11",
"product_id": "26"
},
"product_reference": "4",
"relates_to_product_reference": "6"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.6-GS-01-23116 installed on Microsoft Windows Server 2016",
"product_id": "27"
},
"product_reference": "4",
"relates_to_product_reference": "7"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.6-GS-01-23116 installed on Microsoft Windows Server 2019",
"product_id": "28"
},
"product_reference": "4",
"relates_to_product_reference": "8"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Schneider Electric Easy UPS Online Monitoring Software version 2.6-GS-01-23116 installed on Microsoft Windows Server 2022",
"product_id": "29"
},
"product_reference": "4",
"relates_to_product_reference": "9"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Esjay"
],
"organization": "Trend Micro Zero Day Initiative"
},
{
"names": [
"Nicholas Miles"
],
"organization": "Tenable Network Security"
}
],
"cve": "CVE-2023-29411",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "description",
"text": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29"
],
"known_affected": [
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version v2.6-GA-01-23116 of Schneider Electric Easy UPS Online \nMonitoring Software includes a fix for the vulnerabilities for Microsoft \nsupported versions of Windows (10, 11) and Windows Server (2016, \n2019, 2022) and is available for direct download here: \nhttps://download.schneider-electric.com/files?p_enDocType=Software+-\n+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows\nThe Easy UPS Online Monitoring Software has been discontinued \ncoinciding with the discontinuation of the Easy UPS Online SNMP Cards \n(APV9601, APVS9601) managed by this software.\nNote: The fix applies to all variants of UPS Online Monitoring Software.\nIt is recommended that customers currently using Easy UPS Online \nMonitoring Software to manage Easy UPS Online (SRV/SRVS) to \ntransition to PowerChute Serial Shutdown for serial/USB shutdown and \nmonitoring; and to PowerChute Network Shutdown for network shutdown \nand monitoring. For more information about PowerChute software,\nplease see the following:\nhttps://www.apc.com/pcss\nhttps://www.apc.com/pcns",
"product_ids": [
"10",
"11",
"12",
"13",
"14"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_enDocType=Software+-+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows"
},
{
"category": "vendor_fix",
"details": "Version v2.6-GS-01-23116 of Schneider Electric Easy UPS Online \nMonitoring Software includes a fix for the vulnerabilities for Microsoft \nsupported versions of Windows (10, 11) Windows Server (2016, 2019, \n2022) and is available for direct download here:\nhttps://download.schneider-electric.com/files?p_enDocType=Software+-\n+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows\nThe Easy UPS Online Monitoring Software has been discontinued \ncoinciding with the discontinuation of the Easy UPS Online SNMP Cards \n(APV9601, APVS9601) managed by this software.\nNote: The fix applies to all variants of UPS Online Monitoring Software.\nIt is recommended that customers currently using Easy UPS Online \nMonitoring Software to manage Easy UPS Online (SRV/SRVS) to \ntransition to PowerChute Serial Shutdown for serial/USB shutdown and \nmonitoring; and to PowerChute Network Shutdown for network shutdown \nand monitoring. For more information about PowerChute software,\nplease see the following:\nhttps://www.apc.com/pcss\nhttps://www.apc.com/pcns",
"product_ids": [
"15",
"16",
"17",
"18",
"19"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_enDocType=Software+-+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19"
]
}
],
"title": "CVE-2023-29411"
},
{
"acknowledgments": [
{
"names": [
"Esjay"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2023-29412",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "description",
"text": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29"
],
"known_affected": [
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version v2.6-GA-01-23116 of Schneider Electric Easy UPS Online \nMonitoring Software includes a fix for the vulnerabilities for Microsoft \nsupported versions of Windows (10, 11) and Windows Server (2016, \n2019, 2022) and is available for direct download here: \nhttps://download.schneider-electric.com/files?p_enDocType=Software+-\n+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows\nThe Easy UPS Online Monitoring Software has been discontinued \ncoinciding with the discontinuation of the Easy UPS Online SNMP Cards \n(APV9601, APVS9601) managed by this software.\nNote: The fix applies to all variants of UPS Online Monitoring Software.\nIt is recommended that customers currently using Easy UPS Online \nMonitoring Software to manage Easy UPS Online (SRV/SRVS) to \ntransition to PowerChute Serial Shutdown for serial/USB shutdown and \nmonitoring; and to PowerChute Network Shutdown for network shutdown \nand monitoring. For more information about PowerChute software,\nplease see the following:\nhttps://www.apc.com/pcss\nhttps://www.apc.com/pcns",
"product_ids": [
"10",
"11",
"12",
"13",
"14"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_enDocType=Software+-+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows"
},
{
"category": "vendor_fix",
"details": "Version v2.6-GS-01-23116 of Schneider Electric Easy UPS Online \nMonitoring Software includes a fix for the vulnerabilities for Microsoft \nsupported versions of Windows (10, 11) Windows Server (2016, 2019, \n2022) and is available for direct download here:\nhttps://download.schneider-electric.com/files?p_enDocType=Software+-\n+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows\nThe Easy UPS Online Monitoring Software has been discontinued \ncoinciding with the discontinuation of the Easy UPS Online SNMP Cards \n(APV9601, APVS9601) managed by this software.\nNote: The fix applies to all variants of UPS Online Monitoring Software.\nIt is recommended that customers currently using Easy UPS Online \nMonitoring Software to manage Easy UPS Online (SRV/SRVS) to \ntransition to PowerChute Serial Shutdown for serial/USB shutdown and \nmonitoring; and to PowerChute Network Shutdown for network shutdown \nand monitoring. For more information about PowerChute software,\nplease see the following:\nhttps://www.apc.com/pcss\nhttps://www.apc.com/pcns",
"product_ids": [
"15",
"16",
"17",
"18",
"19"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_enDocType=Software+-+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19"
]
}
],
"title": "CVE-2023-29412"
},
{
"acknowledgments": [
{
"names": [
"Esjay"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2023-29413",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "description",
"text": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29"
],
"known_affected": [
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version v2.6-GA-01-23116 of Schneider Electric Easy UPS Online \nMonitoring Software includes a fix for the vulnerabilities for Microsoft \nsupported versions of Windows (10, 11) and Windows Server (2016, \n2019, 2022) and is available for direct download here: \nhttps://download.schneider-electric.com/files?p_enDocType=Software+-\n+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows\nThe Easy UPS Online Monitoring Software has been discontinued \ncoinciding with the discontinuation of the Easy UPS Online SNMP Cards \n(APV9601, APVS9601) managed by this software.\nNote: The fix applies to all variants of UPS Online Monitoring Software.\nIt is recommended that customers currently using Easy UPS Online \nMonitoring Software to manage Easy UPS Online (SRV/SRVS) to \ntransition to PowerChute Serial Shutdown for serial/USB shutdown and \nmonitoring; and to PowerChute Network Shutdown for network shutdown \nand monitoring. For more information about PowerChute software,\nplease see the following:\nhttps://www.apc.com/pcss\nhttps://www.apc.com/pcns",
"product_ids": [
"10",
"11",
"12",
"13",
"14"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_enDocType=Software+-+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows"
},
{
"category": "vendor_fix",
"details": "Version v2.6-GS-01-23116 of Schneider Electric Easy UPS Online \nMonitoring Software includes a fix for the vulnerabilities for Microsoft \nsupported versions of Windows (10, 11) Windows Server (2016, 2019, \n2022) and is available for direct download here:\nhttps://download.schneider-electric.com/files?p_enDocType=Software+-\n+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows\nThe Easy UPS Online Monitoring Software has been discontinued \ncoinciding with the discontinuation of the Easy UPS Online SNMP Cards \n(APV9601, APVS9601) managed by this software.\nNote: The fix applies to all variants of UPS Online Monitoring Software.\nIt is recommended that customers currently using Easy UPS Online \nMonitoring Software to manage Easy UPS Online (SRV/SRVS) to \ntransition to PowerChute Serial Shutdown for serial/USB shutdown and \nmonitoring; and to PowerChute Network Shutdown for network shutdown \nand monitoring. For more information about PowerChute software,\nplease see the following:\nhttps://www.apc.com/pcss\nhttps://www.apc.com/pcns",
"product_ids": [
"15",
"16",
"17",
"18",
"19"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_enDocType=Software+-+Release\u0026p_Doc_Ref=APC_install_APC_UPS_windows"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19"
]
}
],
"title": "CVE-2023-29413"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.