Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2023-27977 (GCVE-0-2023-27977)
Vulnerability from cvelistv5 – Published: 2023-03-21 00:00 – Updated: 2025-02-05 20:06- CWE-345 - Insufficient Verification of Data Authenticity
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | IGSS Data Server(IGSSdataServer.exe) |
Affected:
V , ≤ 16.0.0.23040
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:23:30.804Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-27977",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:54:51.275436Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:06:06.896Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "IGSS Data Server(IGSSdataServer.exe)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "16.0.0.23040",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
},
{
"product": "IGSS Dashboard (DashBoard.exe)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "16.0.0.23040",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
},
{
"product": "Custom Reports (RMS16.dll)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "16.0.0.23040",
"status": "affected",
"version": "V",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-21T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-27977",
"datePublished": "2023-03-21T00:00:00.000Z",
"dateReserved": "2023-03-09T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:06:06.896Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:custom_reports:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"16.0.0.23040\", \"matchCriteriaId\": \"93DB1B65-C1B5-4A20-ACA7-84EE9C07E9B1\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"16.0.0.23040\", \"matchCriteriaId\": \"CCB39F06-042F-444C-819B-709FF63E060F\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:igss_data_server:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"16.0.0.23040\", \"matchCriteriaId\": \"AE9B5271-999B-4B2B-B4F3-8D99B3A78077\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).\"}]",
"id": "CVE-2023-27977",
"lastModified": "2024-11-21T07:53:51.470",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 2.5}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 1.4}]}",
"published": "2023-03-21T12:15:10.647",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-345\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-27977\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-03-21T12:15:10.647\",\"lastModified\":\"2024-11-21T07:53:51.470\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":2.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-345\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:custom_reports:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.0.0.23040\",\"matchCriteriaId\":\"93DB1B65-C1B5-4A20-ACA7-84EE9C07E9B1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.0.0.23040\",\"matchCriteriaId\":\"CCB39F06-042F-444C-819B-709FF63E060F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:igss_data_server:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.0.0.23040\",\"matchCriteriaId\":\"AE9B5271-999B-4B2B-B4F3-8D99B3A78077\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T12:23:30.804Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-27977\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-05T19:54:51.275436Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-05T19:54:52.766Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"IGSS Data Server(IGSSdataServer.exe)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"16.0.0.23040\"}]}, {\"vendor\": \"Schneider Electric\", \"product\": \"IGSS Dashboard (DashBoard.exe)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"16.0.0.23040\"}]}, {\"vendor\": \"Schneider Electric\", \"product\": \"Custom Reports (RMS16.dll)\", \"versions\": [{\"status\": \"affected\", \"version\": \"V\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"16.0.0.23040\"}]}], \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-345\", \"description\": \"CWE-345 Insufficient Verification of Data Authenticity\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2023-03-21T00:00:00.000Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-27977\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-05T20:06:06.896Z\", \"dateReserved\": \"2023-03-09T00:00:00.000Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2023-03-21T00:00:00.000Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
GSD-2023-27977
Vulnerability from gsd - Updated: 2023-12-13 01:20{
"GSD": {
"alias": "CVE-2023-27977",
"id": "GSD-2023-27977"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-27977"
],
"details": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).",
"id": "GSD-2023-27977",
"modified": "2023-12-13T01:20:55.388884Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2023-27977",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IGSS Data Server(IGSSdataServer.exe)",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "V",
"version_value": "16.0.0.23040"
}
]
}
},
{
"product_name": "IGSS Dashboard (DashBoard.exe)",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "V",
"version_value": "16.0.0.23040"
}
]
}
},
{
"product_name": "Custom Reports (RMS16.dll)",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "V",
"version_value": "16.0.0.23040"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-345 Insufficient Verification of Data Authenticity"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:custom_reports:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "16.0.0.23040",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "16.0.0.23040",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:igss_data_server:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "16.0.0.23040",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2023-27977"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-345"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf",
"refsource": "MISC",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
}
},
"lastModifiedDate": "2023-05-15T15:01Z",
"publishedDate": "2023-03-21T12:15Z"
}
}
}
VAR-202303-1538
Vulnerability from variot - Updated: 2023-12-18 11:54A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability.The specific flaw exists within the IGSSdataServer process, which listens on TCP port 12401 by default. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to create a denial-of-service condition on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202303-1538",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "igss data server",
"scope": "lte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "16.0.0.23040"
},
{
"model": "igss dashboard",
"scope": "lte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "16.0.0.23040"
},
{
"model": "custom reports",
"scope": "lte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "16.0.0.23040"
},
{
"model": "igss dashboard",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "custom reports",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "igss data server",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "igss",
"scope": null,
"trust": 0.7,
"vendor": "schneider electric",
"version": null
},
{
"model": "electric igss data server",
"scope": "lte",
"trust": 0.6,
"vendor": "schneider",
"version": "\u003c=v16.0.0.23040"
},
{
"model": "electric igss dashboard",
"scope": "lte",
"trust": 0.6,
"vendor": "schneider",
"version": "\u003c=v16.0.0.23040"
},
{
"model": "electric custom reports",
"scope": "lte",
"trust": 0.6,
"vendor": "schneider",
"version": "\u003c=v16.0.0.23040"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-335"
},
{
"db": "CNVD",
"id": "CNVD-2023-29371"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-005874"
},
{
"db": "NVD",
"id": "CVE-2023-27977"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:custom_reports:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "16.0.0.23040",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "16.0.0.23040",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:igss_data_server:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "16.0.0.23040",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-27977"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "kimiya",
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-335"
}
],
"trust": 0.7
},
"cve": "CVE-2023-27977",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.4,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-29371",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cybersecurity@se.com",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 2.5,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.3,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2023-27977",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "ZDI",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2023-27977",
"impactScore": 2.5,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-27977",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "cybersecurity@se.com",
"id": "CVE-2023-27977",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "ZDI",
"id": "CVE-2023-27977",
"trust": 0.7,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2023-29371",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202303-1581",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-335"
},
{
"db": "CNVD",
"id": "CNVD-2023-29371"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-005874"
},
{
"db": "NVD",
"id": "CVE-2023-27977"
},
{
"db": "NVD",
"id": "CVE-2023-27977"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1581"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability.The specific flaw exists within the IGSSdataServer process, which listens on TCP port 12401 by default. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to create a denial-of-service condition on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-27977"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-005874"
},
{
"db": "ZDI",
"id": "ZDI-23-335"
},
{
"db": "CNVD",
"id": "CNVD-2023-29371"
},
{
"db": "VULMON",
"id": "CVE-2023-27977"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-27977",
"trust": 4.6
},
{
"db": "SCHNEIDER",
"id": "SEVD-2023-073-04",
"trust": 3.1
},
{
"db": "ICS CERT",
"id": "ICSA-23-082-04",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU94559502",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-005874",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-19654",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-23-335",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2023-29371",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2023.1792",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1581",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-27977",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-335"
},
{
"db": "CNVD",
"id": "CNVD-2023-29371"
},
{
"db": "VULMON",
"id": "CVE-2023-27977"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-005874"
},
{
"db": "NVD",
"id": "CVE-2023-27977"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1581"
}
]
},
"id": "VAR-202303-1538",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-29371"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-29371"
}
]
},
"last_update_date": "2023-12-18T11:54:51.826000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Schneider Electric has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2023-073-04\u0026p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2023-073-04.pdf"
},
{
"title": "Patch for Schneider Electric IGSS Data Server Data Forgery Vulnerability (CNVD-2023-29371)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/419131"
},
{
"title": "Schneider Electric IGSS Data Server Repair measures for data forgery problem vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=230895"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-335"
},
{
"db": "CNVD",
"id": "CNVD-2023-29371"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1581"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-345",
"trust": 1.0
},
{
"problemtype": "Inadequate verification of data reliability (CWE-345) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-005874"
},
{
"db": "NVD",
"id": "CVE-2023-27977"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.8,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2023-073-04\u0026p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2023-073-04.pdf"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu94559502/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-27977"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-04"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-27977/"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2023.1792"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/345.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-335"
},
{
"db": "CNVD",
"id": "CNVD-2023-29371"
},
{
"db": "VULMON",
"id": "CVE-2023-27977"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-005874"
},
{
"db": "NVD",
"id": "CVE-2023-27977"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1581"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-23-335"
},
{
"db": "CNVD",
"id": "CNVD-2023-29371"
},
{
"db": "VULMON",
"id": "CVE-2023-27977"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-005874"
},
{
"db": "NVD",
"id": "CVE-2023-27977"
},
{
"db": "CNNVD",
"id": "CNNVD-202303-1581"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-16T00:00:00",
"db": "ZDI",
"id": "ZDI-23-335"
},
{
"date": "2023-04-20T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-29371"
},
{
"date": "2023-03-21T00:00:00",
"db": "VULMON",
"id": "CVE-2023-27977"
},
{
"date": "2023-11-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-005874"
},
{
"date": "2023-03-21T12:15:10.647000",
"db": "NVD",
"id": "CVE-2023-27977"
},
{
"date": "2023-03-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202303-1581"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-16T00:00:00",
"db": "ZDI",
"id": "ZDI-23-335"
},
{
"date": "2023-04-20T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-29371"
},
{
"date": "2023-03-21T00:00:00",
"db": "VULMON",
"id": "CVE-2023-27977"
},
{
"date": "2023-11-10T05:14:00",
"db": "JVNDB",
"id": "JVNDB-2023-005874"
},
{
"date": "2023-05-15T15:01:28.517000",
"db": "NVD",
"id": "CVE-2023-27977"
},
{
"date": "2023-03-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202303-1581"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202303-1581"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Schneider\u00a0Electric\u00a0 Insufficient Validation of Data Trust in Products Vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-005874"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "data forgery",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202303-1581"
}
],
"trust": 0.6
}
}
CVE-2023-27977
Vulnerability from csaf_se - Published: 2023-03-14 10:58 - Updated: 2023-03-14 10:58Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its Data Server, Dashboard and Custom Reports modules for the IGSS (Interactive Graphical SCADA System) product.\r\nThe IGSS product is a state-of-the art SCADA system used for monitoring and controlling industrial processes. The Data Server is a module with a TCP interface used by other modules like the Dashboard and the Custom Reports to access data of the SCADA System to be presented.\r\nFailure to apply the remediation provided below may result in Denial of Service and dashboards or report files in the IGSS Report folder being lost, added or changed. Further it may risk remote code execution, which could result in a variety of issues including loss of control of the SCADA System with IGSS running in production mode.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cybersecurity@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "IGSS (Interactive Graphical SCADA System) - SEVD-2023-073-04 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
},
{
"category": "self",
"summary": "IGSS (Interactive Graphical SCADA System) - SEVD-2023-073-04 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2023-073-04.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "IGSS (Interactive Graphical SCADA System)",
"tracking": {
"current_release_date": "2023-03-14T10:58:24.000Z",
"generator": {
"date": "2023-03-13T11:35:05.151Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2023-073-04",
"initial_release_date": "2023-03-14T10:58:24.000Z",
"revision_history": [
{
"date": "2023-03-14T10:58:24.000Z",
"number": "1.0.0",
"summary": "Original Release"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=16.0.0.23040",
"product": {
"name": "Schneider Electric IGSS Data Server version 16.0.0.23040 and prior",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "IGSS Data Server"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=16.0.0.23040",
"product": {
"name": "Schneider Electric IGSS Dashboard version 16.0.0.23040 and prior",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "IGSS Dashboard"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=16.0.0.23040",
"product": {
"name": "Schneider Electric Custom Reports version 16.0.0.23040 and prior",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Custom Reports"
},
{
"branches": [
{
"category": "product_version",
"name": "16.0.0.23041",
"product": {
"name": "Schneider Electric IGSS Data Server version 16.0.0.23041",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "IGSS Data Server"
},
{
"branches": [
{
"category": "product_version",
"name": "16.0.0.23041",
"product": {
"name": "Schneider Electric IGSS Dashboard version 16.0.0.23041",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "IGSS Dashboard"
},
{
"branches": [
{
"category": "product_version",
"name": "16.0.0.23041",
"product": {
"name": "Schneider Electric IGSS Custom Reports version 16.0.0.23041",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "IGSS Custom Reports"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Kimiya"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2023-27980",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "description",
"text": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"4",
"5",
"6"
],
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or here:",
"product_ids": [
"1",
"2",
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2023-27980"
},
{
"acknowledgments": [
{
"names": [
"Kimiya"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2023-27982",
"cwe": {
"id": "CWE-345",
"name": "Insufficient Verification of Data Authenticity"
},
"notes": [
{
"category": "description",
"text": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"4",
"5",
"6"
],
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or here:",
"product_ids": [
"1",
"2",
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2023-27982"
},
{
"acknowledgments": [
{
"names": [
"Kimiya"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2023-27978",
"cwe": {
"id": "CWE-502",
"name": "Deserialization of Untrusted Data"
},
"notes": [
{
"category": "description",
"text": "A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"4",
"5",
"6"
],
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or here:",
"product_ids": [
"1",
"2",
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2023-27978"
},
{
"acknowledgments": [
{
"names": [
"Kimiya"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2023-27981",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "description",
"text": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Custom Reports that could cause a remote code execution when a victim tries to open a malicious report.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"4",
"5",
"6"
],
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or here:",
"product_ids": [
"1",
"2",
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2023-27981"
},
{
"acknowledgments": [
{
"names": [
"Kimiya"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2023-27984",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "description",
"text": "A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a malicious report file planted by an attacker.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"4",
"5",
"6"
],
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or here:",
"product_ids": [
"1",
"2",
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2023-27984"
},
{
"acknowledgments": [
{
"names": [
"Kimiya"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2023-27977",
"cwe": {
"id": "CWE-345",
"name": "Insufficient Verification of Data Authenticity"
},
"notes": [
{
"category": "description",
"text": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"4",
"5",
"6"
],
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or here:",
"product_ids": [
"1",
"2",
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2023-27977"
},
{
"acknowledgments": [
{
"names": [
"Kimiya"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2023-27979",
"cwe": {
"id": "CWE-345",
"name": "Insufficient Verification of Data Authenticity"
},
"notes": [
{
"category": "description",
"text": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could allow the renaming of files in the IGSS project report directory, this could lead to denial of service when an attacker sends specific crafted messages to the Data Server TCP port.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"4",
"5",
"6"
],
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or here:",
"product_ids": [
"1",
"2",
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2023-27979"
},
{
"acknowledgments": [
{
"names": [
"Kimiya"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2023-27983",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "description",
"text": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow deletion of reports from the IGSS project report directory, this would lead to loss of data when an attacker abuses this functionality.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"4",
"5",
"6"
],
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or here:",
"product_ids": [
"1",
"2",
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2023-27983"
}
]
}
CERTFR-2023-AVI-0218
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | IGSS Dashboard versions antérieures à 16.0.0.23041 | ||
| Schneider Electric | N/A | Schneider Electric EcoStruxure Power Monitoring Expert version antérieures à 2022 CU1 | ||
| Schneider Electric | N/A | Schneider Electric PowerLogic HDPM6000 versions antérieures à 0.58.7 | ||
| Schneider Electric | N/A | IGSS Custom Reports versions antérieures à 16.0.0.23041 | ||
| Schneider Electric | N/A | IGSS Data Server versions antérieures à 16.0.0.23041 |
| Title | Publication Time | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "IGSS Dashboard versions ant\u00e9rieures \u00e0 16.0.0.23041",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric EcoStruxure Power Monitoring Expert version ant\u00e9rieures \u00e0 2022 CU1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric PowerLogic HDPM6000 versions ant\u00e9rieures \u00e0 0.58.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Custom Reports versions ant\u00e9rieures \u00e0 16.0.0.23041",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Data Server versions ant\u00e9rieures \u00e0 16.0.0.23041",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-27983",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27983"
},
{
"name": "CVE-2023-28003",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28003"
},
{
"name": "CVE-2023-27982",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27982"
},
{
"name": "CVE-2023-27981",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27981"
},
{
"name": "CVE-2023-27979",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27979"
},
{
"name": "CVE-2023-27980",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27980"
},
{
"name": "CVE-2023-28004",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28004"
},
{
"name": "CVE-2023-27984",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27984"
},
{
"name": "CVE-2023-27977",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27977"
},
{
"name": "CVE-2023-27978",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27978"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0218",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-03-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-073-02 du 14 mars 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-02.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-073-04 du 14 mars 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-073-01 du 14 mars 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-01.pdf"
}
]
}
CERTFR-2023-AVI-0218
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | IGSS Dashboard versions antérieures à 16.0.0.23041 | ||
| Schneider Electric | N/A | Schneider Electric EcoStruxure Power Monitoring Expert version antérieures à 2022 CU1 | ||
| Schneider Electric | N/A | Schneider Electric PowerLogic HDPM6000 versions antérieures à 0.58.7 | ||
| Schneider Electric | N/A | IGSS Custom Reports versions antérieures à 16.0.0.23041 | ||
| Schneider Electric | N/A | IGSS Data Server versions antérieures à 16.0.0.23041 |
| Title | Publication Time | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "IGSS Dashboard versions ant\u00e9rieures \u00e0 16.0.0.23041",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric EcoStruxure Power Monitoring Expert version ant\u00e9rieures \u00e0 2022 CU1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric PowerLogic HDPM6000 versions ant\u00e9rieures \u00e0 0.58.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Custom Reports versions ant\u00e9rieures \u00e0 16.0.0.23041",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Data Server versions ant\u00e9rieures \u00e0 16.0.0.23041",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-27983",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27983"
},
{
"name": "CVE-2023-28003",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28003"
},
{
"name": "CVE-2023-27982",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27982"
},
{
"name": "CVE-2023-27981",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27981"
},
{
"name": "CVE-2023-27979",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27979"
},
{
"name": "CVE-2023-27980",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27980"
},
{
"name": "CVE-2023-28004",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28004"
},
{
"name": "CVE-2023-27984",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27984"
},
{
"name": "CVE-2023-27977",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27977"
},
{
"name": "CVE-2023-27978",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27978"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0218",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-03-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-073-02 du 14 mars 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-02.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-073-04 du 14 mars 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2023-073-01 du 14 mars 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-01.pdf"
}
]
}
ICSA-23-082-04
Vulnerability from csaf_cisa - Published: 2023-04-03 19:38 - Updated: 2023-04-03 19:38Notes
{
"document": {
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro Zero Day Initiative",
"summary": "reporting these vulnerabilities to Schneider Electric"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could result in a denial-of-service condition, as well as the loss, addition, or modification of dashboards or report files in the IGSS Report folder. Successful exploitation of these vulnerabilities could also allow remote code execution, potentially resulting in loss of control of the supervisory control and data acquisition (SCADA) System with IGSS running in production mode.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities, Critical Manufacturing, Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have low attack complexity.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-23-082-04 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-082-04.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-082-04 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-04"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/Recommended-Practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://cisa.gov/ics"
}
],
"title": "Schneider Electric IGSS",
"tracking": {
"current_release_date": "2023-04-03T19:38:42.642957Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-082-04",
"initial_release_date": "2023-04-03T19:38:42.642957Z",
"revision_history": [
{
"date": "2023-04-03T19:38:42.642957Z",
"legacy_version": "1",
"number": "1",
"summary": "CSAF Creation Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 16.0.0.23040",
"product": {
"name": "IGSS Data Server (IGSSdataServer.exe): V16.0.0.23040 and prior",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "IGSS Data Server (IGSSdataServer.exe)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 16.0.0.23040",
"product": {
"name": "IGSS Dashboard (DashBoard.exe): V16.0.0.23040 and prior",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "IGSS Dashboard (DashBoard.exe)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 16.0.0.23040",
"product": {
"name": "Custom Reports (RMS16.dll): V16.0.0.23040 and prior",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Custom Reports (RMS16.dll)"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-27980",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in Schneider Electric Data Server TCP interface could allow the creation of a malicious report file in the IGSS project report directory, and this could lead to remote code execution when an unsuspecting user opens the malicious report. CVE-2023-27980 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-27980"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software; the update is also available directly from Schneider Electric.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://igss.schneiderelectric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "Schneider Electric recommends that users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of back-ups and impact evaluating these patches in a test, development, or offline infrastructure environment, is strongly recommended. Users can contact Schneider Electric\u2019s Customer Care Center for additional assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Additionally, if patching is not feasible, Schneider Electric recommends the following mitigations to reduce the risk of vulnerability exploitation:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Read the Security Guideline for IGSS on securing an IGSS SCADA-installation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Ensure that the System Configuration module under Files, automatic backup is enabled for file backup.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Strip report output from Excel output. In the System Configuration module under Reports, stripping of macros for the output engine can be enabled, reducing the risk of distributing an unsafe report.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Verify that devices are isolated on a private network and that firewalls are configured with strict boundaries for devices that require remote access.Schneider Electric strongly recommends the following industry cybersecurity best practices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Install physical controls to help prevent unauthorized users from accessing industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Place all controllers in locked cabinets, and do not leave them in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Only connect programming software to the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Scan all methods of mobile data exchange with the isolated network before use in the terminals or nodes connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Properly sanitize mobile devices that have connected to another network before connecting to the intended network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "vendor_fix",
"details": "For more information, see Schneider Electric security notification SEVD-2023-073-04.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2023-27982",
"cwe": {
"id": "CWE-345",
"name": "Insufficient Verification of Data Authenticity"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in Schneider Electric Data Server could cause manipulation of dashboard files in the IGSS project report directory when an attacker sends specific crafted messages to the Data Server TCP port. This could lead to remote code execution if an unsuspecting user opens the malicious dashboard file. CVE-2023-27982 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-27982"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software; the update is also available directly from Schneider Electric.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://igss.schneiderelectric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "Schneider Electric recommends that users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of back-ups and impact evaluating these patches in a test, development, or offline infrastructure environment, is strongly recommended. Users can contact Schneider Electric\u2019s Customer Care Center for additional assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Additionally, if patching is not feasible, Schneider Electric recommends the following mitigations to reduce the risk of vulnerability exploitation:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Read the Security Guideline for IGSS on securing an IGSS SCADA-installation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Ensure that the System Configuration module under Files, automatic backup is enabled for file backup.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Strip report output from Excel output. In the System Configuration module under Reports, stripping of macros for the output engine can be enabled, reducing the risk of distributing an unsafe report.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Verify that devices are isolated on a private network and that firewalls are configured with strict boundaries for devices that require remote access.Schneider Electric strongly recommends the following industry cybersecurity best practices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Install physical controls to help prevent unauthorized users from accessing industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Place all controllers in locked cabinets, and do not leave them in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Only connect programming software to the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Scan all methods of mobile data exchange with the isolated network before use in the terminals or nodes connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Properly sanitize mobile devices that have connected to another network before connecting to the intended network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "vendor_fix",
"details": "For more information, see Schneider Electric security notification SEVD-2023-073-04.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2023-27978",
"cwe": {
"id": "CWE-502",
"name": "Deserialization of Untrusted Data"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in Schneider Electric Dashboard module could cause an interpretation of malicious payload data if a malicious file is opened by an unsuspecting user. This could lead to remote code execution. CVE-2023-27978 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-27978"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software; the update is also available directly from Schneider Electric.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://igss.schneiderelectric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "Schneider Electric recommends that users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of back-ups and impact evaluating these patches in a test, development, or offline infrastructure environment, is strongly recommended. Users can contact Schneider Electric\u2019s Customer Care Center for additional assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Additionally, if patching is not feasible, Schneider Electric recommends the following mitigations to reduce the risk of vulnerability exploitation:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Read the Security Guideline for IGSS on securing an IGSS SCADA-installation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Ensure that the System Configuration module under Files, automatic backup is enabled for file backup.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Strip report output from Excel output. In the System Configuration module under Reports, stripping of macros for the output engine can be enabled, reducing the risk of distributing an unsafe report.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Verify that devices are isolated on a private network and that firewalls are configured with strict boundaries for devices that require remote access.Schneider Electric strongly recommends the following industry cybersecurity best practices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Install physical controls to help prevent unauthorized users from accessing industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Place all controllers in locked cabinets, and do not leave them in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Only connect programming software to the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Scan all methods of mobile data exchange with the isolated network before use in the terminals or nodes connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Properly sanitize mobile devices that have connected to another network before connecting to the intended network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "vendor_fix",
"details": "For more information, see Schneider Electric security notification SEVD-2023-073-04.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2023-27981",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in Schneider Electric Custom Reports could cause remote code execution if an unsuspecting user opens a malicious report. CVE-2023-27981 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-27981"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software; the update is also available directly from Schneider Electric.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://igss.schneiderelectric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "Schneider Electric recommends that users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of back-ups and impact evaluating these patches in a test, development, or offline infrastructure environment, is strongly recommended. Users can contact Schneider Electric\u2019s Customer Care Center for additional assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Additionally, if patching is not feasible, Schneider Electric recommends the following mitigations to reduce the risk of vulnerability exploitation:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Read the Security Guideline for IGSS on securing an IGSS SCADA-installation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Ensure that the System Configuration module under Files, automatic backup is enabled for file backup.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Strip report output from Excel output. In the System Configuration module under Reports, stripping of macros for the output engine can be enabled, reducing the risk of distributing an unsafe report.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Verify that devices are isolated on a private network and that firewalls are configured with strict boundaries for devices that require remote access.Schneider Electric strongly recommends the following industry cybersecurity best practices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Install physical controls to help prevent unauthorized users from accessing industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Place all controllers in locked cabinets, and do not leave them in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Only connect programming software to the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Scan all methods of mobile data exchange with the isolated network before use in the terminals or nodes connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Properly sanitize mobile devices that have connected to another network before connecting to the intended network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "vendor_fix",
"details": "For more information, see Schneider Electric security notification SEVD-2023-073-04.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2023-27984",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in Schneider Electric Custom Reports could result in macro execution if a malicious report file is opened by an unsuspecting user, potentially leading to remote code execution. CVE-2023-27984 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-27984"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software; the update is also available directly from Schneider Electric.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://igss.schneiderelectric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "Schneider Electric recommends that users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of back-ups and impact evaluating these patches in a test, development, or offline infrastructure environment, is strongly recommended. Users can contact Schneider Electric\u2019s Customer Care Center for additional assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Additionally, if patching is not feasible, Schneider Electric recommends the following mitigations to reduce the risk of vulnerability exploitation:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Read the Security Guideline for IGSS on securing an IGSS SCADA-installation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Ensure that the System Configuration module under Files, automatic backup is enabled for file backup.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Strip report output from Excel output. In the System Configuration module under Reports, stripping of macros for the output engine can be enabled, reducing the risk of distributing an unsafe report.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Verify that devices are isolated on a private network and that firewalls are configured with strict boundaries for devices that require remote access.Schneider Electric strongly recommends the following industry cybersecurity best practices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Install physical controls to help prevent unauthorized users from accessing industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Place all controllers in locked cabinets, and do not leave them in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Only connect programming software to the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Scan all methods of mobile data exchange with the isolated network before use in the terminals or nodes connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Properly sanitize mobile devices that have connected to another network before connecting to the intended network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "vendor_fix",
"details": "For more information, see Schneider Electric security notification SEVD-2023-073-04.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2023-27977",
"cwe": {
"id": "CWE-345",
"name": "Insufficient Verification of Data Authenticity"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in Schneider Electric Data Server could grant an unauthorized user access to delete files in the IGSS project report directory if specific crafted messages are sent to the Data Server TCP port. CVE-2023-27977 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-27977"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software; the update is also available directly from Schneider Electric.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://igss.schneiderelectric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "Schneider Electric recommends that users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of back-ups and impact evaluating these patches in a test, development, or offline infrastructure environment, is strongly recommended. Users can contact Schneider Electric\u2019s Customer Care Center for additional assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Additionally, if patching is not feasible, Schneider Electric recommends the following mitigations to reduce the risk of vulnerability exploitation:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Read the Security Guideline for IGSS on securing an IGSS SCADA-installation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Ensure that the System Configuration module under Files, automatic backup is enabled for file backup.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Strip report output from Excel output. In the System Configuration module under Reports, stripping of macros for the output engine can be enabled, reducing the risk of distributing an unsafe report.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Verify that devices are isolated on a private network and that firewalls are configured with strict boundaries for devices that require remote access.Schneider Electric strongly recommends the following industry cybersecurity best practices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Install physical controls to help prevent unauthorized users from accessing industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Place all controllers in locked cabinets, and do not leave them in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Only connect programming software to the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Scan all methods of mobile data exchange with the isolated network before use in the terminals or nodes connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Properly sanitize mobile devices that have connected to another network before connecting to the intended network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "vendor_fix",
"details": "For more information, see Schneider Electric security notification SEVD-2023-073-04.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2023-27979",
"cwe": {
"id": "CWE-345",
"name": "Insufficient Verification of Data Authenticity"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in Schneider Electric Data Server could allow an unauthorized user to rename files in the IGSS project report directory. This could lead to a denial-of-service condition if an attacker sends specific crafted messages to the Data Server TCP port. CVE-2023-27979 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-27979"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software; the update is also available directly from Schneider Electric.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://igss.schneiderelectric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "Schneider Electric recommends that users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of back-ups and impact evaluating these patches in a test, development, or offline infrastructure environment, is strongly recommended. Users can contact Schneider Electric\u2019s Customer Care Center for additional assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Additionally, if patching is not feasible, Schneider Electric recommends the following mitigations to reduce the risk of vulnerability exploitation:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Read the Security Guideline for IGSS on securing an IGSS SCADA-installation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Ensure that the System Configuration module under Files, automatic backup is enabled for file backup.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Strip report output from Excel output. In the System Configuration module under Reports, stripping of macros for the output engine can be enabled, reducing the risk of distributing an unsafe report.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Verify that devices are isolated on a private network and that firewalls are configured with strict boundaries for devices that require remote access.Schneider Electric strongly recommends the following industry cybersecurity best practices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Install physical controls to help prevent unauthorized users from accessing industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Place all controllers in locked cabinets, and do not leave them in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Only connect programming software to the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Scan all methods of mobile data exchange with the isolated network before use in the terminals or nodes connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Properly sanitize mobile devices that have connected to another network before connecting to the intended network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "vendor_fix",
"details": "For more information, see Schneider Electric security notification SEVD-2023-073-04.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2023-27983",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in Schneider Electric Data Server TCP interface could allow deletion of reports from the IGSS project report directory. CVE-2023-27983 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-27983"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.0.0.23041 of IGSS Data Server, Dashboard and Custom Reports (RMS) includes corrections and mitigations for these vulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software; the update is also available directly from Schneider Electric.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://igss.schneiderelectric.com/igss/igssupdates/v160/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "Schneider Electric recommends that users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of back-ups and impact evaluating these patches in a test, development, or offline infrastructure environment, is strongly recommended. Users can contact Schneider Electric\u2019s Customer Care Center for additional assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Additionally, if patching is not feasible, Schneider Electric recommends the following mitigations to reduce the risk of vulnerability exploitation:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Read the Security Guideline for IGSS on securing an IGSS SCADA-installation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "vendor_fix",
"details": "Ensure that the System Configuration module under Files, automatic backup is enabled for file backup.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Strip report output from Excel output. In the System Configuration module under Reports, stripping of macros for the output engine can be enabled, reducing the risk of distributing an unsafe report.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Verify that devices are isolated on a private network and that firewalls are configured with strict boundaries for devices that require remote access.Schneider Electric strongly recommends the following industry cybersecurity best practices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Install physical controls to help prevent unauthorized users from accessing industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Place all controllers in locked cabinets, and do not leave them in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Only connect programming software to the network intended for that device.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Scan all methods of mobile data exchange with the isolated network before use in the terminals or nodes connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Properly sanitize mobile devices that have connected to another network before connecting to the intended network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "vendor_fix",
"details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
},
{
"category": "vendor_fix",
"details": "For more information, see Schneider Electric security notification SEVD-2023-073-04.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
}
]
}
FKIE_CVE-2023-27977
Vulnerability from fkie_nvd - Published: 2023-03-21 12:15 - Updated: 2024-11-21 07:535.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | custom_reports | * | |
| schneider-electric | igss_dashboard | * | |
| schneider-electric | igss_data_server | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:custom_reports:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93DB1B65-C1B5-4A20-ACA7-84EE9C07E9B1",
"versionEndIncluding": "16.0.0.23040",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CCB39F06-042F-444C-819B-709FF63E060F",
"versionEndIncluding": "16.0.0.23040",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:igss_data_server:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AE9B5271-999B-4B2B-B4F3-8D99B3A78077",
"versionEndIncluding": "16.0.0.23040",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)."
}
],
"id": "CVE-2023-27977",
"lastModified": "2024-11-21T07:53:51.470",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 2.5,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-03-21T12:15:10.647",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-345"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
GHSA-8C9M-95JR-9F2R
Vulnerability from github – Published: 2023-03-21 12:30 – Updated: 2023-03-28 15:30A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
{
"affected": [],
"aliases": [
"CVE-2023-27977"
],
"database_specific": {
"cwe_ids": [
"CWE-345"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-03-21T12:15:00Z",
"severity": "HIGH"
},
"details": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).",
"id": "GHSA-8c9m-95jr-9f2r",
"modified": "2023-03-28T15:30:17Z",
"published": "2023-03-21T12:30:15Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-27977"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.