cve-2022-37130
Vulnerability from cvelistv5
Published
2022-08-31 00:00
Modified
2024-08-03 10:21
Severity ?
EPSS score ?
Summary
In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:21:33.144Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/dlink/Dir816/Diagnosis/readme.md" }, { "tags": [ "x_transferred" ], "url": "https://github.com/726232111/VulIoT/tree/main/D-Link/DIR-816%20A2_v1.10CNB05/Diagnosis" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-03-03T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://github.com/z1r00/IOT_Vul/blob/main/dlink/Dir816/Diagnosis/readme.md" }, { "url": "https://github.com/726232111/VulIoT/tree/main/D-Link/DIR-816%20A2_v1.10CNB05/Diagnosis" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-37130", "datePublished": "2022-08-31T00:00:00", "dateReserved": "2022-08-01T00:00:00", "dateUpdated": "2024-08-03T10:21:33.144Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-37130\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-08-31T23:15:08.293\",\"lastModified\":\"2024-11-21T07:14:29.807\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability\"},{\"lang\":\"es\",\"value\":\"En D-Link DIR-816 versi\u00f3n A2_v1.10CNB04.img, es producida una vulnerabilidad de inyecci\u00f3n de comandos en /goform/Diagnosis, despu\u00e9s de que es cumplida la condici\u00f3n, setnum ser\u00e1 empalmado con v10 mediante snprintf, y ser\u00e1 ejecutado el sistema, resultando en una vulnerabilidad de inyecci\u00f3n de comandos\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dlink:dir-816_firmware:1.10cnb04:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"94848253-66CF-4F67-979E-0913F153A578\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dlink:dir-816:a2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1A3AC507-7219-401E-AC60-12D96382E4B7\"}]}]}],\"references\":[{\"url\":\"https://github.com/726232111/VulIoT/tree/main/D-Link/DIR-816%20A2_v1.10CNB05/Diagnosis\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://github.com/z1r00/IOT_Vul/blob/main/dlink/Dir816/Diagnosis/readme.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.dlink.com/en/security-bulletin/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://github.com/726232111/VulIoT/tree/main/D-Link/DIR-816%20A2_v1.10CNB05/Diagnosis\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://github.com/z1r00/IOT_Vul/blob/main/dlink/Dir816/Diagnosis/readme.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.dlink.com/en/security-bulletin/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.