CVE-2022-28697 (GCVE-0-2022-28697)
Vulnerability from cvelistv5 – Published: 2022-08-18 00:00 – Updated: 2025-05-05 16:21
VLAI
Summary
Improper access control in firmware for Intel(R) AMT and Intel(R) Standard Manageability may allow an unauthenticated user to potentially enable escalation of privilege via physical access.
Severity
6.8 (Medium)
CWE
- escalation of privilege
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) AMT and Intel(R) Standard Manageability |
Affected:
See references
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:03:52.067Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00709.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20221014-0004/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-28697",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T13:30:04.765356Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-noinfo Not enough information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T16:21:23.467Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) AMT and Intel(R) Standard Manageability",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper access control in firmware for Intel(R) AMT and Intel(R) Standard Manageability may allow an unauthenticated user to potentially enable escalation of privilege via physical access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-14T00:00:00.000Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00709.html"
},
{
"url": "https://security.netapp.com/advisory/ntap-20221014-0004/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-28697",
"datePublished": "2022-08-18T00:00:00.000Z",
"dateReserved": "2022-06-09T00:00:00.000Z",
"dateUpdated": "2025-05-05T16:21:23.467Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-28697",
"date": "2026-05-27",
"epss": "0.00186",
"percentile": "0.39997"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:intel:standard_manageability:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5FA8EEF7-DACD-45B8-92A2-CE363D4EDE23\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:intel:active_management_technology_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F802F5D5-BAF0-4246-BEAD-9227BF50EE88\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Improper access control in firmware for Intel(R) AMT and Intel(R) Standard Manageability may allow an unauthenticated user to potentially enable escalation of privilege via physical access.\"}, {\"lang\": \"es\", \"value\": \"Un control de acceso inapropiado en el firmware para Intel(R) AMT e Intel(R) Standard Manageability puede permitir que un usuario no autenticado habilite potencialmente la escalada de privilegios por medio del acceso f\\u00edsico.\"}]",
"id": "CVE-2022-28697",
"lastModified": "2024-11-21T06:57:45.567",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 6.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"PHYSICAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.9, \"impactScore\": 5.9}]}",
"published": "2022-08-18T21:15:08.467",
"references": "[{\"url\": \"https://security.netapp.com/advisory/ntap-20221014-0004/\", \"source\": \"secure@intel.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00709.html\", \"source\": \"secure@intel.com\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20221014-0004/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00709.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "secure@intel.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-28697\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2022-08-18T21:15:08.467\",\"lastModified\":\"2025-05-05T17:18:07.690\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper access control in firmware for Intel(R) AMT and Intel(R) Standard Manageability may allow an unauthenticated user to potentially enable escalation of privilege via physical access.\"},{\"lang\":\"es\",\"value\":\"Un control de acceso inapropiado en el firmware para Intel(R) AMT e Intel(R) Standard Manageability puede permitir que un usuario no autenticado habilite potencialmente la escalada de privilegios por medio del acceso f\u00edsico.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:standard_manageability:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5FA8EEF7-DACD-45B8-92A2-CE363D4EDE23\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:active_management_technology_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F802F5D5-BAF0-4246-BEAD-9227BF50EE88\"}]}]}],\"references\":[{\"url\":\"https://security.netapp.com/advisory/ntap-20221014-0004/\",\"source\":\"secure@intel.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00709.html\",\"source\":\"secure@intel.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20221014-0004/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00709.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00709.html\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20221014-0004/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T06:03:52.067Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.8, \"attackVector\": \"PHYSICAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-28697\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-23T13:30:04.765356Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"description\": \"CWE-noinfo Not enough information\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-05T13:09:58.172Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"Intel(R) AMT and Intel(R) Standard Manageability\", \"versions\": [{\"status\": \"affected\", \"version\": \"See references\"}]}], \"references\": [{\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00709.html\"}, {\"url\": \"https://security.netapp.com/advisory/ntap-20221014-0004/\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Improper access control in firmware for Intel(R) AMT and Intel(R) Standard Manageability may allow an unauthenticated user to potentially enable escalation of privilege via physical access.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"escalation of privilege\"}]}], \"providerMetadata\": {\"orgId\": \"6dda929c-bb53-4a77-a76d-48e79601a1ce\", \"shortName\": \"intel\", \"dateUpdated\": \"2022-10-14T00:00:00.000Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-28697\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-05-05T16:21:23.467Z\", \"dateReserved\": \"2022-06-09T00:00:00.000Z\", \"assignerOrgId\": \"6dda929c-bb53-4a77-a76d-48e79601a1ce\", \"datePublished\": \"2022-08-18T00:00:00.000Z\", \"assignerShortName\": \"intel\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…