CVE-2022-26079 (GCVE-0-2022-26079)

Vulnerability from cvelistv5 – Published: 2022-11-11 15:48 – Updated: 2025-02-05 20:46
VLAI
Summary
Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-29 20:38 UTC
CWE
  • escalation of privilege
  • CWE-754 - Improper Check for Unusual or Exceptional Conditions
Impacted products
Vendor Product Version CPE status
n/a Intel(R) XMM(TM) 7560 Modem software Affected: before version M2_7560_R_01.2146.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:56:37.787Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26079",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:32.347515Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-754",
                "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:46:57.179Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Intel(R) XMM(TM) 7560 Modem software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version M2_7560_R_01.2146.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "escalation of privilege",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T17:46:14.407Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-26079",
    "datePublished": "2022-11-11T15:48:47.785Z",
    "dateReserved": "2022-04-05T15:11:54.308Z",
    "dateUpdated": "2025-02-05T20:46:57.179Z",
    "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-26079",
      "date": "2026-10-05",
      "epss": "0.00182",
      "percentile": "0.07059"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:intel:xmm_7560_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6A636ED6-D919-498E-B1BC-7817B9688F61",
                  "versionEndExcluding": "m2_7560_r_01.2146.00",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:intel:xmm_7560:m.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "65DA746B-280F-4E5C-A944-561D6620611B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
        },
        {
          "lang": "es",
          "value": "La verificaci\u00f3n de condiciones inadecuada en algunos software del m\u00f3dem Intel(R) XMM(TM) 7560 antes de la versi\u00f3n M2_7560_R_01.2146.00 puede permitir que un usuario privilegiado habilite potencialmente la escalada de privilegios a trav\u00e9s del acceso local."
        }
      ],
      "id": "CVE-2022-26079",
      "lastModified": "2024-11-21T06:53:23.627",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.0,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.5,
            "impactScore": 4.0,
            "source": "secure@intel.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 8.2,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.5,
            "impactScore": 6.0,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-11-11T16:15:12.450",
      "references": [
        {
          "source": "secure@intel.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
        }
      ],
      "sourceIdentifier": "secure@intel.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-754"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "Intel(R) XMM(TM) 7560 Modem software",
                "vendor": "n/a",
                "versions": [
                  {
                    "status": "affected",
                    "version": "before version M2_7560_R_01.2146.00"
                  }
                ]
              }
            ],
            "source": "secure@intel.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:intel:xmm_7560_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6A636ED6-D919-498E-B1BC-7817B9688F61",
                    "versionEndExcluding": "m2_7560_r_01.2146.00",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:intel:xmm_7560:m.2:*:*:*:*:*:*:*",
                    "matchCriteriaId": "65DA746B-280F-4E5C-A944-561D6620611B",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
          },
          {
            "lang": "es",
            "value": "La verificaci\u00f3n de condiciones inadecuada en algunos software del m\u00f3dem Intel(R) XMM(TM) 7560 antes de la versi\u00f3n M2_7560_R_01.2146.00 puede permitir que un usuario privilegiado habilite potencialmente la escalada de privilegios a trav\u00e9s del acceso local."
          }
        ],
        "id": "CVE-2022-26079",
        "lastModified": "2026-06-17T04:34:39.090",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.0,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.5,
              "impactScore": 4.0,
              "source": "secure@intel.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.5,
              "impactScore": 6.0,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2022-26079",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-29T20:38:32.347515Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2022-11-11T16:15:12.450",
        "references": [
          {
            "source": "secure@intel.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
          }
        ],
        "sourceIdentifier": "secure@intel.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-754"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-754"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T04:56:37.787Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-26079",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:32.347515Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-754",
                    "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-29T20:38:33.597Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) XMM(TM) 7560 Modem software",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "before version M2_7560_R_01.2146.00"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper conditions check in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:14.407Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00683.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-26079",
        "datePublished": "2022-11-11T15:48:47.785Z",
        "dateReserved": "2022-04-05T15:11:54.308Z",
        "dateUpdated": "2025-02-05T20:46:57.179Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…