cve-2021-45732
Vulnerability from cvelistv5
Published
2021-12-30 21:31
Modified
2024-08-04 04:47
Severity ?
Summary
Netgear Nighthawk R6700 version 1.0.4.120 makes use of a hardcoded credential. It does not appear that normal users are intended to be able to manipulate configuration backups due to the fact that they are encrypted/obfuscated. By extracting the configuration using readily available public tools, a user can reconfigure settings not intended to be manipulated, repackage the configuration, and restore a backup causing these settings to be changed.
Impacted products
Vendor Product Version
n/a Netgear Nighthawk R6700 Version: 1.0.4.120
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:02.172Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2021-57"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Netgear Nighthawk R6700",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.4.120"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Netgear Nighthawk R6700 version 1.0.4.120 makes use of a hardcoded credential. It does not appear that normal users are intended to be able to manipulate configuration backups due to the fact that they are encrypted/obfuscated. By extracting the configuration using readily available public tools, a user can reconfigure settings not intended to be manipulated, repackage the configuration, and restore a backup causing these settings to be changed."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Hardcoded Credentials",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-30T21:31:20",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2021-57"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnreport@tenable.com",
          "ID": "CVE-2021-45732",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Netgear Nighthawk R6700",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.0.4.120"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Netgear Nighthawk R6700 version 1.0.4.120 makes use of a hardcoded credential. It does not appear that normal users are intended to be able to manipulate configuration backups due to the fact that they are encrypted/obfuscated. By extracting the configuration using readily available public tools, a user can reconfigure settings not intended to be manipulated, repackage the configuration, and restore a backup causing these settings to be changed."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Hardcoded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.tenable.com/security/research/tra-2021-57",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2021-57"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2021-45732",
    "datePublished": "2021-12-30T21:31:20",
    "dateReserved": "2021-12-30T00:00:00",
    "dateUpdated": "2024-08-04T04:47:02.172Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-45732\",\"sourceIdentifier\":\"vulnreport@tenable.com\",\"published\":\"2021-12-30T22:15:10.063\",\"lastModified\":\"2024-11-21T06:32:58.407\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Netgear Nighthawk R6700 version 1.0.4.120 makes use of a hardcoded credential. It does not appear that normal users are intended to be able to manipulate configuration backups due to the fact that they are encrypted/obfuscated. By extracting the configuration using readily available public tools, a user can reconfigure settings not intended to be manipulated, repackage the configuration, and restore a backup causing these settings to be changed.\"},{\"lang\":\"es\",\"value\":\"Netgear Nighthawk R6700 versi\u00f3n 1.0.4.120, usa una credencial embebida. No parece que usuarios normales puedan manipular las copias de seguridad de la configuraci\u00f3n debido a que est\u00e1n cifradas/ofuscadas. Al extraer la configuraci\u00f3n usando herramientas p\u00fablicas f\u00e1cilmente disponibles, un usuario puede reconfigurar los ajustes que no est\u00e1n destinados a ser manipulados, volver a empaquetar la configuraci\u00f3n y restaurar una copia de seguridad causando que estos ajustes sean cambiados.\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:r6700_firmware:1.0.4.120:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AA1C8A12-2DF8-4414-ACAF-9AC869331CE9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"21B27F11-4262-4CE1-8107-B365A7C152F2\"}]}]}],\"references\":[{\"url\":\"https://www.tenable.com/security/research/tra-2021-57\",\"source\":\"vulnreport@tenable.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2021-57\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.