cve-2021-41028
Vulnerability from cvelistv5
Published
2021-12-16 18:13
Modified
2024-10-25 13:36
Summary
A combination of a use of hard-coded cryptographic key vulnerability [CWE-321] in FortiClientEMS 7.0.1 and below, 6.4.6 and below and an improper certificate validation vulnerability [CWE-297] in FortiClientWindows, FortiClientLinux and FortiClientMac 7.0.1 and below, 6.4.6 and below may allow an unauthenticated and network adjacent attacker to perform a man-in-the-middle attack between the EMS and the FCT via the telemetry protocol.
Impacted products
Vendor Product Version
Fortinet Fortinet FortiClientEMS, FortiClientWindows, FortiClientLinux, FortiClientMac Version: FortiClientEMS 7.0.1 and below, 6.4.6 and below, FortiClientWindows, FortiClientLinux, FortiClientMac 7.0.1 and below, 6.4.6 and below.
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:59:30.977Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://fortiguard.com/advisory/FG-IR-21-075"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-41028",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T13:57:24.536074Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-25T13:36:27.735Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Fortinet FortiClientEMS, FortiClientWindows, FortiClientLinux, FortiClientMac",
          "vendor": "Fortinet",
          "versions": [
            {
              "status": "affected",
              "version": "FortiClientEMS 7.0.1 and below,  6.4.6 and below, FortiClientWindows, FortiClientLinux, FortiClientMac 7.0.1 and below,  6.4.6 and below."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A combination of a use of hard-coded cryptographic key vulnerability [CWE-321] in FortiClientEMS 7.0.1 and below, 6.4.6 and below and an improper certificate validation vulnerability [CWE-297] in FortiClientWindows, FortiClientLinux and FortiClientMac 7.0.1 and below, 6.4.6 and below may allow an unauthenticated and network adjacent attacker to perform a man-in-the-middle attack between the EMS and the FCT via the telemetry protocol."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "exploitCodeMaturity": "FUNCTIONAL",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "remediationLevel": "UNAVAILABLE",
            "reportConfidence": "CONFIRMED",
            "scope": "CHANGED",
            "temporalScore": 8,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H/E:F/RL:U/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information disclosure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-16T18:13:38",
        "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
        "shortName": "fortinet"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://fortiguard.com/advisory/FG-IR-21-075"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@fortinet.com",
          "ID": "CVE-2021-41028",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Fortinet FortiClientEMS, FortiClientWindows, FortiClientLinux, FortiClientMac",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "FortiClientEMS 7.0.1 and below,  6.4.6 and below, FortiClientWindows, FortiClientLinux, FortiClientMac 7.0.1 and below,  6.4.6 and below."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fortinet"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A combination of a use of hard-coded cryptographic key vulnerability [CWE-321] in FortiClientEMS 7.0.1 and below, 6.4.6 and below and an improper certificate validation vulnerability [CWE-297] in FortiClientWindows, FortiClientLinux and FortiClientMac 7.0.1 and below, 6.4.6 and below may allow an unauthenticated and network adjacent attacker to perform a man-in-the-middle attack between the EMS and the FCT via the telemetry protocol."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "High",
            "attackVector": "Adjacent",
            "availabilityImpact": "High",
            "baseScore": 8,
            "baseSeverity": "High",
            "confidentialityImpact": "Low",
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Changed",
            "userInteraction": "None",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H/E:F/RL:U/RC:C",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Information disclosure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://fortiguard.com/advisory/FG-IR-21-075",
              "refsource": "CONFIRM",
              "url": "https://fortiguard.com/advisory/FG-IR-21-075"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
    "assignerShortName": "fortinet",
    "cveId": "CVE-2021-41028",
    "datePublished": "2021-12-16T18:13:38",
    "dateReserved": "2021-09-13T00:00:00",
    "dateUpdated": "2024-10-25T13:36:27.735Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-41028\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2021-12-16T19:15:08.130\",\"lastModified\":\"2024-11-21T06:25:18.210\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A combination of a use of hard-coded cryptographic key vulnerability [CWE-321] in FortiClientEMS 7.0.1 and below, 6.4.6 and below and an improper certificate validation vulnerability [CWE-297] in FortiClientWindows, FortiClientLinux and FortiClientMac 7.0.1 and below, 6.4.6 and below may allow an unauthenticated and network adjacent attacker to perform a man-in-the-middle attack between the EMS and the FCT via the telemetry protocol.\"},{\"lang\":\"es\",\"value\":\"Una combinaci\u00f3n de una vulnerabilidad de clave criptogr\u00e1fica embebida [CWE-321] en FortiClientEMS versiones 7.0.1 y anteriores, versiones 6.4.6 y anteriores, y una vulnerabilidad de comprobaci\u00f3n de certificado inapropiado [CWE-297] en FortiClientWindows, FortiClientLinux y FortiClientMac versiones 7. 0.1 y anteriores, versiones 6.4.6 y anteriores, pueden permitir a un atacante no autenticado y adyacente a la red llevar a cabo un ataque de tipo man-in-the-middle entre el EMS y el FCT por medio del protocolo de telemetr\u00eda\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.6,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.6,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":5.4,\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":5.5,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-295\"},{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:*:*:*:*:*:macos:*:*\",\"versionStartIncluding\":\"6.0.0\",\"versionEndIncluding\":\"6.0.9\",\"matchCriteriaId\":\"D2E21BE5-4AB4-4E5A-A709-C29177DB5CF3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:*:*:*:*:*:windows:*:*\",\"versionStartIncluding\":\"6.0.0\",\"versionEndIncluding\":\"6.0.9\",\"matchCriteriaId\":\"4BF4B4CA-81E0-42EA-9EA4-66A4414345C9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:*:*:*:*:*:linux:*:*\",\"versionStartIncluding\":\"6.2.0\",\"versionEndIncluding\":\"6.2.9\",\"matchCriteriaId\":\"2F0755CA-2961-4F74-8044-761178AB0312\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:*:*:*:*:*:macos:*:*\",\"versionStartIncluding\":\"6.2.0\",\"versionEndIncluding\":\"6.2.9\",\"matchCriteriaId\":\"6EE22D2E-DE73-47FE-91DE-4C4B8FDB4C0E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:*:*:*:*:*:windows:*:*\",\"versionStartIncluding\":\"6.2.0\",\"versionEndIncluding\":\"6.2.9\",\"matchCriteriaId\":\"C5601CD7-A7CE-4FC5-A635-B20B415DC8C4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:*:*:*:*:*:linux:*:*\",\"versionStartIncluding\":\"6.4.0\",\"versionEndIncluding\":\"6.4.6\",\"matchCriteriaId\":\"586B3E02-6E45-49C1-9B8D-D1892C5A3331\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:*:*:*:*:*:macos:*:*\",\"versionStartIncluding\":\"6.4.0\",\"versionEndIncluding\":\"6.4.6\",\"matchCriteriaId\":\"B842635B-1BB3-4D92-A157-78A0CE71A659\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:*:*:*:*:*:windows:*:*\",\"versionStartIncluding\":\"6.4.0\",\"versionEndIncluding\":\"6.4.6\",\"matchCriteriaId\":\"6001805D-D4FB-4071-AD9C-18B1016FA07A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:7.0.0:*:*:*:*:linux:*:*\",\"matchCriteriaId\":\"F221810A-3FF0-46A6-B8A2-04ABCCF0382D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:7.0.0:*:*:*:*:macos:*:*\",\"matchCriteriaId\":\"63E9F1CD-DF46-4AC5-9EA6-9C63C2816AD4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:7.0.0:*:*:*:*:windows:*:*\",\"matchCriteriaId\":\"43B7F057-9D03-4687-8B04-FDE3A94C3EA3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:7.0.1:*:*:*:*:linux:*:*\",\"matchCriteriaId\":\"41FED871-2D52-41C9-A2EE-F77E63997270\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:7.0.1:*:*:*:*:macos:*:*\",\"matchCriteriaId\":\"DB1D284B-AFF0-4750-8ED1-FB075C42FC83\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient:7.0.1:*:*:*:*:windows:*:*\",\"matchCriteriaId\":\"0F085864-54A6-4928-AF00-982FF6A17F4B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient_endpoint_management_server:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.2.0\",\"versionEndIncluding\":\"6.2.9\",\"matchCriteriaId\":\"D16D1BDE-ED3A-472B-AE5D-9A22B330AD82\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient_endpoint_management_server:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.4.0\",\"versionEndIncluding\":\"6.4.6\",\"matchCriteriaId\":\"EB00205D-D413-4E43-8581-6C6808AD1534\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient_endpoint_management_server:7.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7695C46E-650B-4480-8CCD-BBE91D9633D8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:forticlient_endpoint_management_server:7.0.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9E031A53-6E46-4C38-8DA1-FC592BF0FAAD\"}]}]}],\"references\":[{\"url\":\"https://fortiguard.com/advisory/FG-IR-21-075\",\"source\":\"psirt@fortinet.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://fortiguard.com/advisory/FG-IR-21-075\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://fortiguard.com/advisory/FG-IR-21-075\", \"tags\": [\"x_refsource_CONFIRM\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T02:59:30.977Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2021-41028\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-23T13:57:24.536074Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-23T13:58:23.078Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 8.2, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H/E:F/RL:U/RC:C\", \"temporalScore\": 8, \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"remediationLevel\": \"UNAVAILABLE\", \"reportConfidence\": \"CONFIRMED\", \"temporalSeverity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"exploitCodeMaturity\": \"FUNCTIONAL\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Fortinet\", \"product\": \"Fortinet FortiClientEMS, FortiClientWindows, FortiClientLinux, FortiClientMac\", \"versions\": [{\"status\": \"affected\", \"version\": \"FortiClientEMS 7.0.1 and below,  6.4.6 and below, FortiClientWindows, FortiClientLinux, FortiClientMac 7.0.1 and below,  6.4.6 and below.\"}]}], \"references\": [{\"url\": \"https://fortiguard.com/advisory/FG-IR-21-075\", \"tags\": [\"x_refsource_CONFIRM\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A combination of a use of hard-coded cryptographic key vulnerability [CWE-321] in FortiClientEMS 7.0.1 and below, 6.4.6 and below and an improper certificate validation vulnerability [CWE-297] in FortiClientWindows, FortiClientLinux and FortiClientMac 7.0.1 and below, 6.4.6 and below may allow an unauthenticated and network adjacent attacker to perform a man-in-the-middle attack between the EMS and the FCT via the telemetry protocol.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"Information disclosure\"}]}], \"providerMetadata\": {\"orgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"shortName\": \"fortinet\", \"dateUpdated\": \"2021-12-16T18:13:38\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"scope\": \"Changed\", \"version\": \"3.1\", \"baseScore\": 8, \"attackVector\": \"Adjacent\", \"baseSeverity\": \"High\", \"vectorString\": \"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H/E:F/RL:U/RC:C\", \"integrityImpact\": \"High\", \"userInteraction\": \"None\", \"attackComplexity\": \"High\", \"availabilityImpact\": \"High\", \"privilegesRequired\": \"None\", \"confidentialityImpact\": \"Low\"}}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"FortiClientEMS 7.0.1 and below,  6.4.6 and below, FortiClientWindows, FortiClientLinux, FortiClientMac 7.0.1 and below,  6.4.6 and below.\"}]}, \"product_name\": \"Fortinet FortiClientEMS, FortiClientWindows, FortiClientLinux, FortiClientMac\"}]}, \"vendor_name\": \"Fortinet\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://fortiguard.com/advisory/FG-IR-21-075\", \"name\": \"https://fortiguard.com/advisory/FG-IR-21-075\", \"refsource\": \"CONFIRM\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A combination of a use of hard-coded cryptographic key vulnerability [CWE-321] in FortiClientEMS 7.0.1 and below, 6.4.6 and below and an improper certificate validation vulnerability [CWE-297] in FortiClientWindows, FortiClientLinux and FortiClientMac 7.0.1 and below, 6.4.6 and below may allow an unauthenticated and network adjacent attacker to perform a man-in-the-middle attack between the EMS and the FCT via the telemetry protocol.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"Information disclosure\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2021-41028\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"psirt@fortinet.com\"}}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2021-41028\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-25T13:36:27.735Z\", \"dateReserved\": \"2021-09-13T00:00:00\", \"assignerOrgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"datePublished\": \"2021-12-16T18:13:38\", \"assignerShortName\": \"fortinet\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.