CVE-2021-22709 (GCVE-0-2021-22709)
Vulnerability from cvelistv5 – Published: 2021-03-11 20:27 – Updated: 2024-08-03 18:51- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior |
Affected:
Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.101Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-11T20:27:13",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22709",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior",
"version": {
"version_data": [
{
"version_value": "Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-068-01",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-01"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22709",
"datePublished": "2021-03-11T20:27:13",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.101Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"15.0.0.21041\", \"matchCriteriaId\": \"3CC174AC-AAAA-4BA4-B23F-F6F08103EF38\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.\"}, {\"lang\": \"es\", \"value\": \"Una CWE-119: se presenta una vulnerabilidad de Restricci\\u00f3n Inapropiada de Operaciones dentro de los L\\u00edmites de un B\\u00fafer de Memoria en Interactive Graphical SCADA System (IGSS) Definition (Def.exe) versiones V15.0.0.21041 y anteriores, lo que podr\\u00eda resultar en la p\\u00e9rdida de datos o una ejecuci\\u00f3n de c\\u00f3digo remota cuando es importado un archivo CGF (Configuration Group File) malicioso para IGSS Definition\"}]",
"id": "CVE-2021-22709",
"lastModified": "2024-11-21T05:50:30.430",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:C/I:C/A:C\", \"baseScore\": 9.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.6, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2021-03-11T21:15:12.077",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2021-068-01\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Broken Link\", \"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2021-068-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Broken Link\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-22709\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2021-03-11T21:15:12.077\",\"lastModified\":\"2024-11-21T05:50:30.430\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.\"},{\"lang\":\"es\",\"value\":\"Una CWE-119: se presenta una vulnerabilidad de Restricci\u00f3n Inapropiada de Operaciones dentro de los L\u00edmites de un B\u00fafer de Memoria en Interactive Graphical SCADA System (IGSS) Definition (Def.exe) versiones V15.0.0.21041 y anteriores, lo que podr\u00eda resultar en la p\u00e9rdida de datos o una ejecuci\u00f3n de c\u00f3digo remota cuando es importado un archivo CGF (Configuration Group File) malicioso para IGSS Definition\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":9.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"15.0.0.21041\",\"matchCriteriaId\":\"3CC174AC-AAAA-4BA4-B23F-F6F08103EF38\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2021-068-01\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Broken Link\",\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2021-068-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\",\"Vendor Advisory\"]}]}}"
}
}
GHSA-X8RR-7C53-PC84
Vulnerability from github – Published: 2022-05-24 17:44 – Updated: 2022-05-24 17:44A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
{
"affected": [],
"aliases": [
"CVE-2021-22709"
],
"database_specific": {
"cwe_ids": [
"CWE-119"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-03-11T21:15:00Z",
"severity": "HIGH"
},
"details": "A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.",
"id": "GHSA-x8rr-7c53-pc84",
"modified": "2022-05-24T17:44:16Z",
"published": "2022-05-24T17:44:16Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-22709"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
},
{
"type": "WEB",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-01"
}
],
"schema_version": "1.4.0",
"severity": []
}
CERTFR-2021-AVI-175
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | IGSS Definition (Def.exe) version antérieures à 15.0.0.21042 | ||
| N/A | N/A | ION7400 versions antérieures à 3.0.0 | ||
| N/A | N/A | ION8650 versions antérieures à 4.40.1 | ||
| N/A | N/A | ION8800 versions antérieures à 372 | ||
| N/A | N/A | ION7650 (Hardware rev. 5*) versions antérieures à 416 | ||
| N/A | N/A | PM8000 versions antérieures à 3.0.0 | ||
| N/A | N/A | ION7700/73xx toutes versions | ||
| N/A | N/A | ION83xx/84xx/85xx/8600 toutes versions | ||
| N/A | N/A | ION7650 (Hardware rev. 4 or earlier*) versions antérieures à 376 | ||
| N/A | N/A | ION9000 versions antérieures à 3.0.0 |
| Title | Publication Time | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "IGSS Definition (Def.exe) version ant\u00e9rieures \u00e0 15.0.0.21042",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION7400 versions ant\u00e9rieures \u00e0 3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION8650 versions ant\u00e9rieures \u00e0 4.40.1",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION8800 versions ant\u00e9rieures \u00e0 372",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION7650 (Hardware rev. 5*) versions ant\u00e9rieures \u00e0 416",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PM8000 versions ant\u00e9rieures \u00e0 3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION7700/73xx toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION83xx/84xx/85xx/8600 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION7650 (Hardware rev. 4 or earlier*) versions ant\u00e9rieures \u00e0 376",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION9000 versions ant\u00e9rieures \u00e0 3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-22712",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22712"
},
{
"name": "CVE-2021-22709",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22709"
},
{
"name": "CVE-2021-22713",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22713"
},
{
"name": "CVE-2021-22710",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22710"
},
{
"name": "CVE-2021-22714",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22714"
},
{
"name": "CVE-2021-22711",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22711"
}
],
"links": [],
"reference": "CERTFR-2021-AVI-175",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-03-10T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-068-02 du 09 mars 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-068-01 du 09 mars 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-068-03 du 09 mars 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-03"
}
]
}
CERTFR-2021-AVI-175
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | IGSS Definition (Def.exe) version antérieures à 15.0.0.21042 | ||
| N/A | N/A | ION7400 versions antérieures à 3.0.0 | ||
| N/A | N/A | ION8650 versions antérieures à 4.40.1 | ||
| N/A | N/A | ION8800 versions antérieures à 372 | ||
| N/A | N/A | ION7650 (Hardware rev. 5*) versions antérieures à 416 | ||
| N/A | N/A | PM8000 versions antérieures à 3.0.0 | ||
| N/A | N/A | ION7700/73xx toutes versions | ||
| N/A | N/A | ION83xx/84xx/85xx/8600 toutes versions | ||
| N/A | N/A | ION7650 (Hardware rev. 4 or earlier*) versions antérieures à 376 | ||
| N/A | N/A | ION9000 versions antérieures à 3.0.0 |
| Title | Publication Time | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "IGSS Definition (Def.exe) version ant\u00e9rieures \u00e0 15.0.0.21042",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION7400 versions ant\u00e9rieures \u00e0 3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION8650 versions ant\u00e9rieures \u00e0 4.40.1",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION8800 versions ant\u00e9rieures \u00e0 372",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION7650 (Hardware rev. 5*) versions ant\u00e9rieures \u00e0 416",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PM8000 versions ant\u00e9rieures \u00e0 3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION7700/73xx toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION83xx/84xx/85xx/8600 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION7650 (Hardware rev. 4 or earlier*) versions ant\u00e9rieures \u00e0 376",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION9000 versions ant\u00e9rieures \u00e0 3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-22712",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22712"
},
{
"name": "CVE-2021-22709",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22709"
},
{
"name": "CVE-2021-22713",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22713"
},
{
"name": "CVE-2021-22710",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22710"
},
{
"name": "CVE-2021-22714",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22714"
},
{
"name": "CVE-2021-22711",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22711"
}
],
"links": [],
"reference": "CERTFR-2021-AVI-175",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-03-10T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-068-02 du 09 mars 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-068-01 du 09 mars 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-068-03 du 09 mars 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-03"
}
]
}
CVE-2021-22709
Vulnerability from csaf_se - Published: 2021-03-09 00:00 - Updated: 2021-03-09 00:00Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in the Interactive Graphical SCADA \r\nSystem (IGSS) product. \r\nThe IGSS product is a state-of-the art SCADA system used for monitoring and controlling \r\nindustrial processes. IGSS communicates with all major industry standard PLC drivers. \r\nFailure to apply the remediations provided below may risk remote code execution, which could \r\nresult in an attacker gaining access to the Windows Operating System on the machine used to \r\nimport CGF files, typically a step performed during system design time.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "IGSS (Interactive Graphical SCADA System) - SEVD-2021-068-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-068-01_IGSS_Security_Notification.pdf"
},
{
"category": "self",
"summary": "IGSS (Interactive Graphical SCADA System) - SEVD-2021-068-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2021-068-01.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "IGSS (Interactive Graphical SCADA System)",
"tracking": {
"current_release_date": "2021-03-09T00:00:00.000Z",
"generator": {
"date": "2021-03-09T00:00:00Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2021-068-01",
"initial_release_date": "2021-03-09T00:00:00.000Z",
"revision_history": [
{
"date": "2021-03-09T00:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=15.0.0.21041",
"product": {
"name": "Schneider Electric IGSS Definition (Def.exe) version 15.0.0.21041 and prior",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "IGSS Definition (Def.exe)"
},
{
"branches": [
{
"category": "product_version",
"name": "15.0.0.21042",
"product": {
"name": "Schneider Electric IGSS Definition (Def.exe) Version 15.0.0.21042",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "IGSS Definition (Def.exe)"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro\u0027s Zero Day Initiative"
}
],
"cve": "CVE-2021-22709",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "description",
"text": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer \r\nvulnerability exists that could result in loss of data or remote code execution when malicious \r\nCGF (Configuration Group File) file is imported to IGSS Definition.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 15.0.0.21042 of the IGSS Definition module: Def.exe includes a fix for each of these\r\nvulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or \r\nhere:\r\nCustomers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u0027s Customer Care Center if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Avoid importing CGF files from untrusted sources.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2021-22709"
},
{
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro\u0027s Zero Day Initiative"
}
],
"cve": "CVE-2021-22710",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "description",
"text": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer\r\nvulnerability exists that could cause remote code execution when malicious CGF (Configuration \r\nGroup File) file is imported to IGSS Definition.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 15.0.0.21042 of the IGSS Definition module: Def.exe includes a fix for each of these\r\nvulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or \r\nhere:\r\nCustomers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u0027s Customer Care Center if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Avoid importing CGF files from untrusted sources.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2021-22710"
},
{
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro\u0027s Zero Day Initiative"
}
],
"cve": "CVE-2021-22711",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "description",
"text": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer \r\nvulnerability exists that could result in arbitrary read or write conditions when malicious CGF \r\n(Configuration Group File) file is imported to IGSS Definition due to missing validation of input \r\ndata.\r\n",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 15.0.0.21042 of the IGSS Definition module: Def.exe includes a fix for each of these\r\nvulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or \r\nhere:\r\nCustomers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u0027s Customer Care Center if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Avoid importing CGF files from untrusted sources.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2021-22711"
},
{
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro\u0027s Zero Day Initiative"
}
],
"cve": "CVE-2021-22712",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "description",
"text": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer \r\nvulnerability exists that could result in arbitrary read or write conditions when malicious CGF \r\n(Configuration Group File) file is imported to IGSS Definition due to an unchecked pointer \r\naddress.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 15.0.0.21042 of the IGSS Definition module: Def.exe includes a fix for each of these\r\nvulnerabilities and is available for download through IGSS Master \u003e Update IGSS Software or \r\nhere:\r\nCustomers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u0027s Customer Care Center if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Avoid importing CGF files from untrusted sources.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2021-22712"
}
]
}
CNVD-2021-18389
Vulnerability from cnvd - Published: 2021-03-18目前厂商已发布升级补丁以修复漏洞,补丁获取链接: https://www.se.com/ww/en/download/document/SEVD-2021-068-01
| Name | Schneider Electric Interactive Graphical SCADA System (IGSS) Definition <=V15.0.0.21041 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2021-22709",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2021-22709"
}
},
"description": "Schneider Electric Interactive Graphical SCADA System\uff08IGSS\uff09\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u5957\u7528\u4e8e\u76d1\u63a7\u548c\u63a7\u5236\u5de5\u4e1a\u8fc7\u7a0b\u7684SCADA\uff08\u6570\u636e\u91c7\u96c6\u4e0e\u76d1\u63a7\u7cfb\u7edf\uff09\u7cfb\u7edf\u3002\n\nInteractive Graphical SCADA System (IGSS) Definition V15.0.0.21041\u53ca\u4e4b\u524d\u7248\u672c\u5b58\u5728\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u901a\u8fc7\u5bfc\u5165\u6076\u610fCGF\uff08\u914d\u7f6e\u7ec4\u6587\u4ef6\uff09\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u6570\u636e\u4e22\u5931\u6216\u8fdc\u7a0b\u4ee3\u7801\u6267\u884c\u3002",
"formalWay": "\u76ee\u524d\u5382\u5546\u5df2\u53d1\u5e03\u5347\u7ea7\u8865\u4e01\u4ee5\u4fee\u590d\u6f0f\u6d1e\uff0c\u8865\u4e01\u83b7\u53d6\u94fe\u63a5\uff1a\r\nhttps://www.se.com/ww/en/download/document/SEVD-2021-068-01",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2021-18389",
"openTime": "2021-03-18",
"patchDescription": "Schneider Electric Interactive Graphical SCADA System\uff08IGSS\uff09\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u5957\u7528\u4e8e\u76d1\u63a7\u548c\u63a7\u5236\u5de5\u4e1a\u8fc7\u7a0b\u7684SCADA\uff08\u6570\u636e\u91c7\u96c6\u4e0e\u76d1\u63a7\u7cfb\u7edf\uff09\u7cfb\u7edf\u3002\r\n\r\nInteractive Graphical SCADA System (IGSS) Definition V15.0.0.21041\u53ca\u4e4b\u524d\u7248\u672c\u5b58\u5728\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u901a\u8fc7\u5bfc\u5165\u6076\u610fCGF\uff08\u914d\u7f6e\u7ec4\u6587\u4ef6\uff09\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u6570\u636e\u4e22\u5931\u6216\u8fdc\u7a0b\u4ee3\u7801\u6267\u884c\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric Interactive Graphical SCADA System\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff08CNVD-2021-18389\uff09\u7684\u8865\u4e01",
"products": {
"product": "Schneider Electric Interactive Graphical SCADA System (IGSS) Definition \u003c=V15.0.0.21041"
},
"referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2021-22709",
"serverity": "\u9ad8",
"submitTime": "2021-03-17",
"title": "Schneider Electric Interactive Graphical SCADA System\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff08CNVD-2021-18389\uff09"
}
GSD-2021-22709
Vulnerability from gsd - Updated: 2023-12-13 01:23{
"GSD": {
"alias": "CVE-2021-22709",
"description": "A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.",
"id": "GSD-2021-22709"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-22709"
],
"details": "A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.",
"id": "GSD-2021-22709",
"modified": "2023-12-13T01:23:24.332077Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22709",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior",
"version": {
"version_data": [
{
"version_value": "Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-068-01",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-01"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0.0.21041",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22709"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-068-01",
"refsource": "MISC",
"tags": [
"Broken Link",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-01"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01",
"refsource": "MISC",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": true
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2021-03-17T20:24Z",
"publishedDate": "2021-03-11T21:15Z"
}
}
}
FKIE_CVE-2021-22709
Vulnerability from fkie_nvd - Published: 2021-03-11 21:15 - Updated: 2024-11-21 05:50| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01 | Patch, Vendor Advisory | |
| cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2021-068-01 | Broken Link, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01 | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2021-068-01 | Broken Link, Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | interactive_graphical_scada_system | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3CC174AC-AAAA-4BA4-B23F-F6F08103EF38",
"versionEndIncluding": "15.0.0.21041",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition."
},
{
"lang": "es",
"value": "Una CWE-119: se presenta una vulnerabilidad de Restricci\u00f3n Inapropiada de Operaciones dentro de los L\u00edmites de un B\u00fafer de Memoria en Interactive Graphical SCADA System (IGSS) Definition (Def.exe) versiones V15.0.0.21041 y anteriores, lo que podr\u00eda resultar en la p\u00e9rdida de datos o una ejecuci\u00f3n de c\u00f3digo remota cuando es importado un archivo CGF (Configuration Group File) malicioso para IGSS Definition"
}
],
"id": "CVE-2021-22709",
"lastModified": "2024-11-21T05:50:30.430",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-03-11T21:15:12.077",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Broken Link",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-01"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
VAR-202103-0440
Vulnerability from variot - Updated: 2023-12-18 11:57A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. Interactive Graphical SCADA System (IGSS) Is vulnerable to a buffer error.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of CGF files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Schneider Electric Interactive Graphical SCADA System (IGSS) is a set of SCADA (Data Acquisition and Supervisory Control System) system used by French Schneider Electric (Schneider Electric) to monitor and control industrial processes.
Interactive Graphical SCADA System (IGSS) Definition V15.0.0.21041 and earlier versions have a buffer overflow vulnerability
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202103-0440",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "interactive graphical scada system",
"scope": "lte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "15.0.0.21041"
},
{
"model": "interactive graphical scada system",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "interactive graphical scada system",
"scope": "lte",
"trust": 0.8,
"vendor": "schneider electric",
"version": "15.0.0.21041 and earlier"
},
{
"model": "igss",
"scope": null,
"trust": 0.7,
"vendor": "schneider electric",
"version": null
},
{
"model": "electric interactive graphical scada system definition",
"scope": "lte",
"trust": 0.6,
"vendor": "schneider",
"version": "\u003c=v15.0.0.21041"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-272"
},
{
"db": "CNVD",
"id": "CNVD-2021-18389"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004400"
},
{
"db": "NVD",
"id": "CVE-2021-22709"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0.0.21041",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22709"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "kimiya",
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-272"
}
],
"trust": 0.7
},
"cve": "CVE-2021-22709",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 9.3,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2021-22709",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "CNVD-2021-18389",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "VHN-381183",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-22709",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2021-22709",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2021-22709",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "ZDI",
"id": "CVE-2021-22709",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2021-18389",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202103-806",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-381183",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-272"
},
{
"db": "CNVD",
"id": "CNVD-2021-18389"
},
{
"db": "VULHUB",
"id": "VHN-381183"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004400"
},
{
"db": "NVD",
"id": "CVE-2021-22709"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-806"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. Interactive Graphical SCADA System (IGSS) Is vulnerable to a buffer error.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of CGF files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Schneider Electric Interactive Graphical SCADA System (IGSS) is a set of SCADA (Data Acquisition and Supervisory Control System) system used by French Schneider Electric (Schneider Electric) to monitor and control industrial processes. \n\r\n\r\nInteractive Graphical SCADA System (IGSS) Definition V15.0.0.21041 and earlier versions have a buffer overflow vulnerability",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22709"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004400"
},
{
"db": "ZDI",
"id": "ZDI-21-272"
},
{
"db": "CNVD",
"id": "CNVD-2021-18389"
},
{
"db": "VULHUB",
"id": "VHN-381183"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-22709",
"trust": 3.8
},
{
"db": "SCHNEIDER",
"id": "SEVD-2021-068-01",
"trust": 1.7
},
{
"db": "ZDI",
"id": "ZDI-21-272",
"trust": 1.3
},
{
"db": "JVN",
"id": "JVNVU92960744",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004400",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-12599",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2021-18389",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2021.0888",
"trust": 0.6
},
{
"db": "ICS CERT",
"id": "ICSA-21-070-01",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202103-806",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-381183",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-272"
},
{
"db": "CNVD",
"id": "CNVD-2021-18389"
},
{
"db": "VULHUB",
"id": "VHN-381183"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004400"
},
{
"db": "NVD",
"id": "CVE-2021-22709"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-806"
}
]
},
"id": "VAR-202103-0440",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-18389"
},
{
"db": "VULHUB",
"id": "VHN-381183"
}
],
"trust": 1.29090906
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-18389"
}
]
},
"last_update_date": "2023-12-18T11:57:31.530000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Product\u00a0Documentation\u00a0\u0026\u00a0Software\u00a0downloads Schneider\u00a0Electric\u00a0Security\u00a0Notification",
"trust": 0.8,
"url": "https://www.se.com/ww/en/download/document/sevd-2021-068-01"
},
{
"title": "Schneider Electric has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2021-068-01"
},
{
"title": "Patch for Schneider Electric Interactive Graphical SCADA System buffer overflow vulnerability (CNVD-2021-18389)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/253511"
},
{
"title": "Schneider Electric Interactive Graphical SCADA System Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=144187"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-272"
},
{
"db": "CNVD",
"id": "CNVD-2021-18389"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004400"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-806"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.1
},
{
"problemtype": "Buffer error (CWE-119) [ Other ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-381183"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004400"
},
{
"db": "NVD",
"id": "CVE-2021-22709"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2021-068-01"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-22709"
},
{
"trust": 1.7,
"url": "https://www.se.com/ww/en/download/document/sevd-2021-068-01"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu92960744/"
},
{
"trust": 0.6,
"url": "https://www.zerodayinitiative.com/advisories/zdi-21-272/"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-070-01"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2021.0888"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-272"
},
{
"db": "CNVD",
"id": "CNVD-2021-18389"
},
{
"db": "VULHUB",
"id": "VHN-381183"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004400"
},
{
"db": "NVD",
"id": "CVE-2021-22709"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-806"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-21-272"
},
{
"db": "CNVD",
"id": "CNVD-2021-18389"
},
{
"db": "VULHUB",
"id": "VHN-381183"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004400"
},
{
"db": "NVD",
"id": "CVE-2021-22709"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-806"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-11T00:00:00",
"db": "ZDI",
"id": "ZDI-21-272"
},
{
"date": "2021-03-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-18389"
},
{
"date": "2021-03-11T00:00:00",
"db": "VULHUB",
"id": "VHN-381183"
},
{
"date": "2021-11-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-004400"
},
{
"date": "2021-03-11T21:15:12.077000",
"db": "NVD",
"id": "CVE-2021-22709"
},
{
"date": "2021-03-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202103-806"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-11T00:00:00",
"db": "ZDI",
"id": "ZDI-21-272"
},
{
"date": "2021-03-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-18389"
},
{
"date": "2021-03-17T00:00:00",
"db": "VULHUB",
"id": "VHN-381183"
},
{
"date": "2021-11-19T07:20:00",
"db": "JVNDB",
"id": "JVNDB-2021-004400"
},
{
"date": "2021-03-17T20:24:30.050000",
"db": "NVD",
"id": "CVE-2021-22709"
},
{
"date": "2021-03-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202103-806"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202103-806"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Interactive\u00a0Graphical\u00a0SCADA\u00a0System\u00a0 Buffer Error Vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-004400"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202103-806"
}
],
"trust": 0.6
}
}
ICSA-21-070-01
Vulnerability from csaf_cisa - Published: 2021-03-11 00:00 - Updated: 2021-03-11 00:00Notes
{
"document": {
"acknowledgments": [
{
"names": [
"Kimiya"
],
"organization": "Trend Micro \u0027s Zero Day Initiative",
"summary": "reporting these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could result in remote code execution.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities, Critical Manufacturing, Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "\\No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-21-070-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-070-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-070-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-070-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ncas/tips/ST04-014"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric IGSS SCADA Software",
"tracking": {
"current_release_date": "2021-03-11T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-070-01",
"initial_release_date": "2021-03-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-03-11T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-21-070-01 Schneider Electric IGSS SCADA Software"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 15.0.0.21041",
"product": {
"name": "IGSS Definition (Def.exe): Version 15.0.0.21041 and prior",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "IGSS Definition (Def.exe)"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-22709",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "This vulnerability could result in loss of data or remote code execution when a malicious CGF (configuration group file) file is imported into an IGSS Definition.CVE-2021-22709 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22709"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has provided Version 15.0.0.21042 of the IGSS Definition module: Def.exe to address these vulnerabilities. The update is available for download through IGSS Master \u003e Update IGSS Software or from the Schneider Electric support page.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "Avoid importing CGF files from untrusted sources.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information, see the Schneider Electric security notification.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2021-22710",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "This vulnerability could result in loss of data or remote code execution when a malicious CGF file is imported into an IGSS Definition.CVE-2021-22710 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22710"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has provided Version 15.0.0.21042 of the IGSS Definition module: Def.exe to address these vulnerabilities. The update is available for download through IGSS Master \u003e Update IGSS Software or from the Schneider Electric support page.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "Avoid importing CGF files from untrusted sources.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information, see the Schneider Electric security notification.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2021-22711",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "This vulnerability could result in arbitrary read or write conditions due to missing validation of input data when a malicious CGF file is imported into an IGSS Definition.CVE-2021-22711 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22711"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has provided Version 15.0.0.21042 of the IGSS Definition module: Def.exe to address these vulnerabilities. The update is available for download through IGSS Master \u003e Update IGSS Software or from the Schneider Electric support page.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "Avoid importing CGF files from untrusted sources.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information, see the Schneider Electric security notification.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2021-22712",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "This vulnerability could result in arbitrary read or write conditions due to an unchecked pointer address when a malicious CGF file is imported into an IGSS Definition.CVE-2021-22712 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22712"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has provided Version 15.0.0.21042 of the IGSS Definition module: Def.exe to address these vulnerabilities. The update is available for download through IGSS Master \u003e Update IGSS Software or from the Schneider Electric support page.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/igss/igssupdates/v150/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "Avoid importing CGF files from untrusted sources.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information, see the Schneider Electric security notification.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.