Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-7555 (GCVE-0-2020-7555)
Vulnerability from cvelistv5 – Published: 2020-11-19 21:08 – Updated: 2024-08-04 09:33- CWE-787 - Out-of-bounds Write
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | IGSS Definition (Def.exe) version 14.0.0.20247 and prior |
Affected:
IGSS Definition (Def.exe) version 14.0.0.20247 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.526Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-094/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "IGSS Definition (Def.exe) version 14.0.0.20247 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "IGSS Definition (Def.exe) version 14.0.0.20247 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-29T16:06:11",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-094/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7555",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IGSS Definition (Def.exe) version 14.0.0.20247 and prior",
"version": {
"version_data": [
{
"version_value": "IGSS Definition (Def.exe) version 14.0.0.20247 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787 Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-094/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-094/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7555",
"datePublished": "2020-11-19T21:08:00",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.526Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"14.0.0.20247\", \"matchCriteriaId\": \"C299CAA6-D174-4217-97D9-7CDC9B9AD094\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.\"}, {\"lang\": \"es\", \"value\": \"Se presenta una vulnerabilidad de Escritura Fuera de L\\u00edmites CWE-787 en IGSS Definition (Def.exe) versi\\u00f3n 14.0.0.20247 que podr\\u00eda causar una Ejecuci\\u00f3n de C\\u00f3digo Remota cuando se importa un archivo CGF (Configuration Group File) malicioso en IGSS Definition\"}]",
"id": "CVE-2020-7555",
"lastModified": "2024-11-21T05:37:22.303",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2020-11-19T22:15:14.520",
"references": "[{\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2020-315-03/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-21-094/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2020-315-03/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-21-094/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-7555\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2020-11-19T22:15:14.520\",\"lastModified\":\"2024-11-21T05:37:22.303\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.\"},{\"lang\":\"es\",\"value\":\"Se presenta una vulnerabilidad de Escritura Fuera de L\u00edmites CWE-787 en IGSS Definition (Def.exe) versi\u00f3n 14.0.0.20247 que podr\u00eda causar una Ejecuci\u00f3n de C\u00f3digo Remota cuando se importa un archivo CGF (Configuration Group File) malicioso en IGSS Definition\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"14.0.0.20247\",\"matchCriteriaId\":\"C299CAA6-D174-4217-97D9-7CDC9B9AD094\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-315-03/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-094/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-315-03/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-094/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}"
}
}
GHSA-F6XM-7HH7-HHMF
Vulnerability from github – Published: 2022-05-24 17:34 – Updated: 2022-05-24 17:34A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
{
"affected": [],
"aliases": [
"CVE-2020-7555"
],
"database_specific": {
"cwe_ids": [
"CWE-787"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-11-19T22:15:00Z",
"severity": "HIGH"
},
"details": "A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.",
"id": "GHSA-f6xm-7hh7-hhmf",
"modified": "2022-05-24T17:34:44Z",
"published": "2022-05-24T17:34:44Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-7555"
},
{
"type": "WEB",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03"
},
{
"type": "WEB",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-094"
}
],
"schema_version": "1.4.0",
"severity": []
}
CVE-2020-7555
Vulnerability from csaf_se - Published: 2020-11-10 00:00 - Updated: 2021-04-15 00:00Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in the Interactive Graphical SCADA\r\nSystem (IGSS) product.\r\nThe IGSS product is a state-of-the art SCADA system used for monitoring and controlling \r\nindustrial processes. IGSS communicates with all major industry standard PLC drivers. \r\nFailure to apply the remediations provided below may risk remote code execution, which could \r\nresult in an attacker gaining access to the Windows Operating System on the machine used to \r\nimport CGF files, typically a step performed during system design time.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Interactive Graphical SCADA System (IGSS) - SEVD-2020-315-03 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-315-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2020-315-03_IGSS_Security_Notification_V1.1.pdf"
},
{
"category": "self",
"summary": "Interactive Graphical SCADA System (IGSS) - SEVD-2020-315-03 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-315-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2020-315-03.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "Interactive Graphical SCADA System (IGSS)",
"tracking": {
"current_release_date": "2021-04-15T00:00:00.000Z",
"generator": {
"date": "2021-04-15T00:00:00Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2020-315-03",
"initial_release_date": "2020-11-10T00:00:00.000Z",
"revision_history": [
{
"date": "2020-11-10T00:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2021-04-15T00:00:00.000Z",
"number": "1.1.0",
"summary": "Updated CWE for CVE-2020-7551 and CVE-2020-7552"
}
],
"status": "final",
"version": "1.1.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=14.0.0.20247",
"product": {
"name": "Schneider Electric IGSS Definition (Def.exe) versions 14.0.0.20247 and prior",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "IGSS Definition (Def.exe)"
},
{
"branches": [
{
"category": "product_version",
"name": "14.0.0.20248",
"product": {
"name": "Schneider Electric IGSS Definition module: Def.exe Version 14.0.0.20248",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "IGSS Definition module: Def.exe"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro\u0027s Zero Day Initiative"
}
],
"cve": "CVE-2020-7550",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "description",
"text": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer\r\nvulnerability exists that could cause Remote Code Execution when malicious CGF \r\n(Configuration Group File) file is imported to IGSS Definition.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 14.0.0.20248 of the IGSS Definition module: Def.exe includes a fix for this vulnerability \r\nand is available for download through IGSS Master \u003e Update IGSS Software or here: \r\nhttps://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP\r\nCustomers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u2019s Customer Care Center https://www.se.com/us/en/work/support/ if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "\r\nCustomers should also consider upgrading to the latest product offering IGSS V15: \r\nhttps://igss.schneider-electric.com/licensed-versions/ to resolve this issue.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Avoid importing CGF files from untrusted sources.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2020-7550"
},
{
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro\u0027s Zero Day Initiative"
}
],
"cve": "CVE-2020-7551",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "CWE-787: Out-of-bounds Write vulnerability exists that could cause Remote Code Execution\r\nwhen malicious CGF (Configuration Group File) file is imported to IGSS Definition.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 14.0.0.20248 of the IGSS Definition module: Def.exe includes a fix for this vulnerability \r\nand is available for download through IGSS Master \u003e Update IGSS Software or here: \r\nhttps://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP\r\nCustomers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u2019s Customer Care Center https://www.se.com/us/en/work/support/ if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "\r\nCustomers should also consider upgrading to the latest product offering IGSS V15: \r\nhttps://igss.schneider-electric.com/licensed-versions/ to resolve this issue.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Avoid importing CGF files from untrusted sources.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2020-7551"
},
{
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro\u0027s Zero Day Initiative"
}
],
"cve": "CVE-2020-7552",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "CWE-787: Out-of-bounds Write vulnerability exists that could cause Remote Code Execution\r\nwhen malicious CGF (Configuration Group File) file is imported to IGSS Definition.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 14.0.0.20248 of the IGSS Definition module: Def.exe includes a fix for this vulnerability \r\nand is available for download through IGSS Master \u003e Update IGSS Software or here: \r\nhttps://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP\r\nCustomers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u2019s Customer Care Center https://www.se.com/us/en/work/support/ if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "\r\nCustomers should also consider upgrading to the latest product offering IGSS V15: \r\nhttps://igss.schneider-electric.com/licensed-versions/ to resolve this issue.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Avoid importing CGF files from untrusted sources.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2020-7552"
},
{
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro\u0027s Zero Day Initiative"
}
],
"cve": "CVE-2020-7553",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "CWE-787 Out-of-bounds Write vulnerability exists that could cause Remote Code Execution\r\nwhen malicious CGF (Configuration Group File) file is imported to IGSS Definition.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 14.0.0.20248 of the IGSS Definition module: Def.exe includes a fix for this vulnerability \r\nand is available for download through IGSS Master \u003e Update IGSS Software or here: \r\nhttps://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP\r\nCustomers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u2019s Customer Care Center https://www.se.com/us/en/work/support/ if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "\r\nCustomers should also consider upgrading to the latest product offering IGSS V15: \r\nhttps://igss.schneider-electric.com/licensed-versions/ to resolve this issue.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Avoid importing CGF files from untrusted sources.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2020-7553"
},
{
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro\u0027s Zero Day Initiative"
}
],
"cve": "CVE-2020-7554",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "description",
"text": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer\r\nvulnerability exists that could cause Remote Code Execution when malicious CGF \r\n(Configuration Group File) file is imported to IGSS Definition.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 14.0.0.20248 of the IGSS Definition module: Def.exe includes a fix for this vulnerability \r\nand is available for download through IGSS Master \u003e Update IGSS Software or here: \r\nhttps://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP\r\nCustomers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u2019s Customer Care Center https://www.se.com/us/en/work/support/ if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "\r\nCustomers should also consider upgrading to the latest product offering IGSS V15: \r\nhttps://igss.schneider-electric.com/licensed-versions/ to resolve this issue.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Avoid importing CGF files from untrusted sources.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2020-7554"
},
{
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro\u0027s Zero Day Initiative"
}
],
"cve": "CVE-2020-7555",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "CWE-787 Out-of-bounds Write vulnerability exists that could cause Remote Code Execution\r\nwhen malicious CGF (Configuration Group File) file is imported to IGSS Definition.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 14.0.0.20248 of the IGSS Definition module: Def.exe includes a fix for this vulnerability \r\nand is available for download through IGSS Master \u003e Update IGSS Software or here: \r\nhttps://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP\r\nCustomers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u2019s Customer Care Center https://www.se.com/us/en/work/support/ if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "\r\nCustomers should also consider upgrading to the latest product offering IGSS V15: \r\nhttps://igss.schneider-electric.com/licensed-versions/ to resolve this issue.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Avoid importing CGF files from untrusted sources.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2020-7555"
},
{
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro\u0027s Zero Day Initiative"
}
],
"cve": "CVE-2020-7556",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "CWE-787 Out-of-bounds Write vulnerability exists that could cause Remote Code Execution\r\nwhen malicious CGF (Configuration Group File) file is imported to IGSS Definition.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 14.0.0.20248 of the IGSS Definition module: Def.exe includes a fix for this vulnerability \r\nand is available for download through IGSS Master \u003e Update IGSS Software or here: \r\nhttps://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP\r\nCustomers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u2019s Customer Care Center https://www.se.com/us/en/work/support/ if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "\r\nCustomers should also consider upgrading to the latest product offering IGSS V15: \r\nhttps://igss.schneider-electric.com/licensed-versions/ to resolve this issue.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Avoid importing CGF files from untrusted sources.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2020-7556"
},
{
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro\u0027s Zero Day Initiative"
}
],
"cve": "CVE-2020-7557",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "description",
"text": "CWE-125 Out-of-bounds Read vulnerability exists that could cause Remote Code Execution\r\nwhen malicious CGF (Configuration Group File) file is imported to IGSS Definition.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 14.0.0.20248 of the IGSS Definition module: Def.exe includes a fix for this vulnerability \r\nand is available for download through IGSS Master \u003e Update IGSS Software or here: \r\nhttps://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP\r\nCustomers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u2019s Customer Care Center https://www.se.com/us/en/work/support/ if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "\r\nCustomers should also consider upgrading to the latest product offering IGSS V15: \r\nhttps://igss.schneider-electric.com/licensed-versions/ to resolve this issue.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Avoid importing CGF files from untrusted sources.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2020-7557"
},
{
"acknowledgments": [
{
"names": [
"kimiya"
],
"organization": "Trend Micro\u0027s Zero Day Initiative"
}
],
"cve": "CVE-2020-7558",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "CWE-787 Out-of-bounds Write vulnerability exists that could cause Remote Code Execution\r\nwhen malicious CGF (Configuration Group File) file is imported to IGSS Definition.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 14.0.0.20248 of the IGSS Definition module: Def.exe includes a fix for this vulnerability \r\nand is available for download through IGSS Master \u003e Update IGSS Software or here: \r\nhttps://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP\r\nCustomers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u2019s Customer Care Center https://www.se.com/us/en/work/support/ if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "vendor_fix",
"details": "\r\nCustomers should also consider upgrading to the latest product offering IGSS V15: \r\nhttps://igss.schneider-electric.com/licensed-versions/ to resolve this issue.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Avoid importing CGF files from untrusted sources.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://igss.schneider-electric.com/licensed-versions/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2020-7558"
}
]
}
CERTFR-2020-AVI-726
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Premium processors avec Ethernet COPRO intégré (TSXP574634, TSXP575634, TSXP576634) toutes versions | ||
| Schneider Electric | N/A | Modicon M221 toutes références et toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for EcoStruxure Control Expert toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebStation versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions | ||
| Schneider Electric | N/A | J Data Radios toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions antérieures (les ordinateurs Windows utilisant un UEFI ne sont pas impactés) | ||
| Schneider Electric | N/A | M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions | ||
| Schneider Electric | N/A | Quantum processors avec Ethernet COPRO intégré 140CPU65xxxxx toutes versions | ||
| Schneider Electric | N/A | M340 CPUs BMX P34x toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Server installer versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Trio Q toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebReports versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Premium communication modules (TSXETY4103, TSXETY5103) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Central installer versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | IGSS Definition (Def.exe) version 14.0.0.20247 et versions antérieures | ||
| Schneider Electric | N/A | Easergy T300 versions antérieures à 2.7 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Premium processors avec Ethernet COPRO int\u00e9gr\u00e9 (TSXP574634, TSXP575634, TSXP576634) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M221 toutes r\u00e9f\u00e9rences et toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for EcoStruxure Control Expert toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebStation versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "J Data Radios toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions ant\u00e9rieures (les ordinateurs Windows utilisant un UEFI ne sont pas impact\u00e9s)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum processors avec Ethernet COPRO int\u00e9gr\u00e9 140CPU65xxxxx toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 CPUs BMX P34x toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Server installer versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Trio Q toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebReports versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Premium communication modules (TSXETY4103, TSXETY5103) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Central installer versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Definition (Def.exe) version 14.0.0.20247 et versions ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easergy T300 versions ant\u00e9rieures \u00e0 2.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-7564",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7564"
},
{
"name": "CVE-2020-7563",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7563"
},
{
"name": "CVE-2020-7558",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7558"
},
{
"name": "CVE-2020-7561",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7561"
},
{
"name": "CVE-2020-7555",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7555"
},
{
"name": "CVE-2020-7565",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7565"
},
{
"name": "CVE-2020-7570",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7570"
},
{
"name": "CVE-2020-7572",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7572"
},
{
"name": "CVE-2020-28213",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28213"
},
{
"name": "CVE-2020-7554",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7554"
},
{
"name": "CVE-2020-7557",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7557"
},
{
"name": "CVE-2020-7550",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7550"
},
{
"name": "CVE-2020-7553",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7553"
},
{
"name": "CVE-2020-7559",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7559"
},
{
"name": "CVE-2020-7566",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7566"
},
{
"name": "CVE-2020-7538",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7538"
},
{
"name": "CVE-2020-7556",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7556"
},
{
"name": "CVE-2020-28212",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28212"
},
{
"name": "CVE-2020-7562",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7562"
},
{
"name": "CVE-2020-7571",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7571"
},
{
"name": "CVE-2020-7552",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7552"
},
{
"name": "CVE-2020-28211",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28211"
},
{
"name": "CVE-2020-7551",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7551"
},
{
"name": "CVE-2020-7567",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7567"
},
{
"name": "CVE-2020-7544",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7544"
}
],
"links": [],
"reference": "CERTFR-2020-AVI-726",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-11-12T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-05 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-03 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-07 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-01/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-04 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-06 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-06/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-02 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SESB-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SESB-2020-315-01/"
}
]
}
CERTFR-2020-AVI-726
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Premium processors avec Ethernet COPRO intégré (TSXP574634, TSXP575634, TSXP576634) toutes versions | ||
| Schneider Electric | N/A | Modicon M221 toutes références et toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for EcoStruxure Control Expert toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebStation versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions | ||
| Schneider Electric | N/A | J Data Radios toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions antérieures (les ordinateurs Windows utilisant un UEFI ne sont pas impactés) | ||
| Schneider Electric | N/A | M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions | ||
| Schneider Electric | N/A | Quantum processors avec Ethernet COPRO intégré 140CPU65xxxxx toutes versions | ||
| Schneider Electric | N/A | M340 CPUs BMX P34x toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Server installer versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Trio Q toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebReports versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Premium communication modules (TSXETY4103, TSXETY5103) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Central installer versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | IGSS Definition (Def.exe) version 14.0.0.20247 et versions antérieures | ||
| Schneider Electric | N/A | Easergy T300 versions antérieures à 2.7 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Premium processors avec Ethernet COPRO int\u00e9gr\u00e9 (TSXP574634, TSXP575634, TSXP576634) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M221 toutes r\u00e9f\u00e9rences et toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for EcoStruxure Control Expert toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebStation versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "J Data Radios toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions ant\u00e9rieures (les ordinateurs Windows utilisant un UEFI ne sont pas impact\u00e9s)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum processors avec Ethernet COPRO int\u00e9gr\u00e9 140CPU65xxxxx toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 CPUs BMX P34x toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Server installer versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Trio Q toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebReports versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Premium communication modules (TSXETY4103, TSXETY5103) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Central installer versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Definition (Def.exe) version 14.0.0.20247 et versions ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easergy T300 versions ant\u00e9rieures \u00e0 2.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-7564",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7564"
},
{
"name": "CVE-2020-7563",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7563"
},
{
"name": "CVE-2020-7558",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7558"
},
{
"name": "CVE-2020-7561",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7561"
},
{
"name": "CVE-2020-7555",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7555"
},
{
"name": "CVE-2020-7565",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7565"
},
{
"name": "CVE-2020-7570",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7570"
},
{
"name": "CVE-2020-7572",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7572"
},
{
"name": "CVE-2020-28213",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28213"
},
{
"name": "CVE-2020-7554",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7554"
},
{
"name": "CVE-2020-7557",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7557"
},
{
"name": "CVE-2020-7550",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7550"
},
{
"name": "CVE-2020-7553",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7553"
},
{
"name": "CVE-2020-7559",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7559"
},
{
"name": "CVE-2020-7566",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7566"
},
{
"name": "CVE-2020-7538",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7538"
},
{
"name": "CVE-2020-7556",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7556"
},
{
"name": "CVE-2020-28212",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28212"
},
{
"name": "CVE-2020-7562",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7562"
},
{
"name": "CVE-2020-7571",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7571"
},
{
"name": "CVE-2020-7552",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7552"
},
{
"name": "CVE-2020-28211",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28211"
},
{
"name": "CVE-2020-7551",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7551"
},
{
"name": "CVE-2020-7567",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7567"
},
{
"name": "CVE-2020-7544",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7544"
}
],
"links": [],
"reference": "CERTFR-2020-AVI-726",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-11-12T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-05 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-03 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-07 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-01/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-04 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-06 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-06/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-02 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SESB-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SESB-2020-315-01/"
}
]
}
FKIE_CVE-2020-7555
Vulnerability from fkie_nvd - Published: 2020-11-19 22:15 - Updated: 2024-11-21 05:37| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2020-315-03/ | Vendor Advisory | |
| cybersecurity@se.com | https://www.zerodayinitiative.com/advisories/ZDI-21-094/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2020-315-03/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-21-094/ | Third Party Advisory, VDB Entry |
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | interactive_graphical_scada_system | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C299CAA6-D174-4217-97D9-7CDC9B9AD094",
"versionEndIncluding": "14.0.0.20247",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de Escritura Fuera de L\u00edmites CWE-787 en IGSS Definition (Def.exe) versi\u00f3n 14.0.0.20247 que podr\u00eda causar una Ejecuci\u00f3n de C\u00f3digo Remota cuando se importa un archivo CGF (Configuration Group File) malicioso en IGSS Definition"
}
],
"id": "CVE-2020-7555",
"lastModified": "2024-11-21T05:37:22.303",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-11-19T22:15:14.520",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-094/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-094/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
ICSA-20-324-04
Vulnerability from csaf_cisa - Published: 2020-11-17 00:00 - Updated: 2020-11-17 00:00Notes
{
"document": {
"acknowledgments": [
{
"names": [
"Kimiya"
],
"organization": "Trend Micro \u0027s Zero Day Initiative",
"summary": "reporting these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities may result in remote code execution.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities, Critical Manufacturing, Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take the following measures to protect themselves from social engineering attacks:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-324-04 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-324-04.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-324-04 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-324-04"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ncas/tips/ST04-014"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric Interactive Graphical SCADA System (IGSS)",
"tracking": {
"current_release_date": "2020-11-17T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-20-324-04",
"initial_release_date": "2020-11-17T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-11-17T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 14.0.0.20247",
"product": {
"name": "IGSS Definition (Def.exe): Version 14.0.0.20247 and prior",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "IGSS Definition (Def.exe)"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-7550",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "An improper restriction of operations within the bounds of a memory buffer vulnerability could cause remote code execution when a malicious CGF (Configuration Group File) is imported to IGSS Definition.CVE-2020-7550 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7550"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has provided a new version of the IGSS Definition module to address these vulnerabilities. Users are recommended to update to IGSS Version 14.0.0.20248",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "Avoid importing CGF files from untrusted sources",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Users should also consider upgrading to the latest product offering IGSS v15 to resolve this issue.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "For more information, see Schneider Electric security notification SEVD-2020-315-03",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2020-7551",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "An improper restriction of operations within the bounds of a memory buffer vulnerability could cause remote code execution when a malicious CGF (Configuration Group File) is imported to IGSS Definition.CVE-2020-7551 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7551"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has provided a new version of the IGSS Definition module to address these vulnerabilities. Users are recommended to update to IGSS Version 14.0.0.20248",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "Avoid importing CGF files from untrusted sources",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Users should also consider upgrading to the latest product offering IGSS v15 to resolve this issue.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "For more information, see Schneider Electric security notification SEVD-2020-315-03",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2020-7552",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "An improper restriction of operations within the bounds of a memory buffer vulnerability could cause remote code execution when a malicious CGF (Configuration Group File) is imported to IGSS Definition.CVE-2020-7552 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7552"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has provided a new version of the IGSS Definition module to address these vulnerabilities. Users are recommended to update to IGSS Version 14.0.0.20248",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "Avoid importing CGF files from untrusted sources",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Users should also consider upgrading to the latest product offering IGSS v15 to resolve this issue.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "For more information, see Schneider Electric security notification SEVD-2020-315-03",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2020-7553",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds write vulnerability could cause remote code execution when a malicious CGF (Configuration Group File) is imported to IGSS Definition.CVE-2020-7553 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7553"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has provided a new version of the IGSS Definition module to address these vulnerabilities. Users are recommended to update to IGSS Version 14.0.0.20248",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "Avoid importing CGF files from untrusted sources",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Users should also consider upgrading to the latest product offering IGSS v15 to resolve this issue.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "For more information, see Schneider Electric security notification SEVD-2020-315-03",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2020-7554",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "An improper restriction of operations within the bounds of a memory buffer vulnerability could cause remote code execution when a malicious CGF (Configuration Group File) is imported to IGSS Definition.CVE-2020-7554 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7554"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has provided a new version of the IGSS Definition module to address these vulnerabilities. Users are recommended to update to IGSS Version 14.0.0.20248",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "Avoid importing CGF files from untrusted sources",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Users should also consider upgrading to the latest product offering IGSS v15 to resolve this issue.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "For more information, see Schneider Electric security notification SEVD-2020-315-03",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2020-7555",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds write vulnerability could cause remote code execution when a malicious CGF (Configuration Group File) file is imported to IGSS Definition.CVE-2020-7555 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7555"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has provided a new version of the IGSS Definition module to address these vulnerabilities. Users are recommended to update to IGSS Version 14.0.0.20248",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "Avoid importing CGF files from untrusted sources",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Users should also consider upgrading to the latest product offering IGSS v15 to resolve this issue.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "For more information, see Schneider Electric security notification SEVD-2020-315-03",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2020-7556",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds write vulnerability could cause remote code execution when a malicious CGF (Configuration Group File) is imported to IGSS Definition.CVE-2020-7556 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7556"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has provided a new version of the IGSS Definition module to address these vulnerabilities. Users are recommended to update to IGSS Version 14.0.0.20248",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "Avoid importing CGF files from untrusted sources",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Users should also consider upgrading to the latest product offering IGSS v15 to resolve this issue.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "For more information, see Schneider Electric security notification SEVD-2020-315-03",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2020-7557",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds read vulnerability could cause remote code execution when a malicious CGF (Configuration Group File) is imported to IGSS Definition.CVE-2020-7557 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7557"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has provided a new version of the IGSS Definition module to address these vulnerabilities. Users are recommended to update to IGSS Version 14.0.0.20248",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "Avoid importing CGF files from untrusted sources",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Users should also consider upgrading to the latest product offering IGSS v15 to resolve this issue.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "For more information, see Schneider Electric security notification SEVD-2020-315-03",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2020-7558",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds write vulnerability could cause remote code execution when a malicious CGF (Configuration Group File) is imported to IGSS Definition.CVE-2020-7558 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7558"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has provided a new version of the IGSS Definition module to address these vulnerabilities. Users are recommended to update to IGSS Version 14.0.0.20248",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/igss/igssupdates/v140/IGSSUPDATE.ZIP"
},
{
"category": "mitigation",
"details": "Avoid importing CGF files from untrusted sources",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Users should also consider upgrading to the latest product offering IGSS v15 to resolve this issue.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://igss.schneider-electric.com/licensed-versions/"
},
{
"category": "mitigation",
"details": "For more information, see Schneider Electric security notification SEVD-2020-315-03",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
CNVD-2021-31182
Vulnerability from cnvd - Published: 2021-04-26用户可参考如下厂商提供的安全补丁以修复该漏洞: https://www.se.com/us/en/
| Name | Schneider Electric Interactive Graphical SCADA System <=14.0.0.20247 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2020-7555",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2020-7555"
}
},
"description": "Schneider Electric Interactive Graphical SCADA System\uff08IGSS\uff09\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u5957\u7528\u4e8e\u76d1\u63a7\u548c\u63a7\u5236\u5de5\u4e1a\u8fc7\u7a0b\u7684SCADA\uff08\u6570\u636e\u91c7\u96c6\u4e0e\u76d1\u63a7\u7cfb\u7edf\uff09\u7cfb\u7edf\u3002\n\nInteractive Graphical SCADA System 14.0.0.20247\u53ca\u4e4b\u524d\u7248\u672c\u5b58\u5728\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u501f\u52a9\u6076\u610fCGF\u6587\u4ef6\u5229\u7528\u8be5\u6f0f\u6d1e\u6267\u884c\u8fdc\u7a0b\u4ee3\u7801\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u5382\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u8865\u4e01\u4ee5\u4fee\u590d\u8be5\u6f0f\u6d1e\uff1a\r\nhttps://www.se.com/us/en/",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2021-31182",
"openTime": "2021-04-26",
"patchDescription": "Schneider Electric Interactive Graphical SCADA System\uff08IGSS\uff09\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u5957\u7528\u4e8e\u76d1\u63a7\u548c\u63a7\u5236\u5de5\u4e1a\u8fc7\u7a0b\u7684SCADA\uff08\u6570\u636e\u91c7\u96c6\u4e0e\u76d1\u63a7\u7cfb\u7edf\uff09\u7cfb\u7edf\u3002\r\n\r\nInteractive Graphical SCADA System 14.0.0.20247\u53ca\u4e4b\u524d\u7248\u672c\u5b58\u5728\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u501f\u52a9\u6076\u610fCGF\u6587\u4ef6\u5229\u7528\u8be5\u6f0f\u6d1e\u6267\u884c\u8fdc\u7a0b\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric Interactive Graphical SCADA System\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Schneider Electric Interactive Graphical SCADA System \u003c=14.0.0.20247"
},
"referenceLink": "https://us-cert.cisa.gov/ics/advisories/icsa-20-324-04",
"serverity": "\u4e2d",
"submitTime": "2020-11-23",
"title": "Schneider Electric Interactive Graphical SCADA System\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e"
}
GSD-2020-7555
Vulnerability from gsd - Updated: 2023-12-13 01:21{
"GSD": {
"alias": "CVE-2020-7555",
"description": "A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.",
"id": "GSD-2020-7555"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-7555"
],
"details": "A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.",
"id": "GSD-2020-7555",
"modified": "2023-12-13T01:21:51.985995Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7555",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IGSS Definition (Def.exe) version 14.0.0.20247 and prior",
"version": {
"version_data": [
{
"version_value": "IGSS Definition (Def.exe) version 14.0.0.20247 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787 Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-094/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-094/"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "14.0.0.20247",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7555"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-094/",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-094/"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": true
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2021-01-30T01:25Z",
"publishedDate": "2020-11-19T22:15Z"
}
}
}
VAR-202011-1291
Vulnerability from variot - Updated: 2023-12-18 12:16A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. Interactive Graphical SCADA System (IGSS) Is Schneider Electric Software for monitoring and controlling control systems provided by the company. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of CGF files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated data structure. An attacker can leverage this vulnerability to execute code in the context of the current process.
Interactive Graphical SCADA System 14.0.0.20247 and earlier versions have an out-of-bounds write vulnerability
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202011-1291",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "interactive graphical scada system",
"scope": "lte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "14.0.0.20247"
},
{
"model": "interactive graphical scada system",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": "version 14.0.0.20247"
},
{
"model": "igss",
"scope": null,
"trust": 0.7,
"vendor": "schneider electric",
"version": null
},
{
"model": "electric interactive graphical scada system",
"scope": "lte",
"trust": 0.6,
"vendor": "schneider",
"version": "\u003c=14.0.0.20247"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-094"
},
{
"db": "CNVD",
"id": "CNVD-2021-31182"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "NVD",
"id": "CVE-2020-7555"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "14.0.0.20247",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-7555"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "kimiya",
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-094"
}
],
"trust": 0.7
},
"cve": "CVE-2020-7555",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CNVD-2021-31182",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "VHN-185680",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-009593",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 7.2,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2020-7555",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "IPA",
"id": "JVNDB-2020-009593",
"trust": 7.2,
"value": "High"
},
{
"author": "NVD",
"id": "CVE-2020-7555",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "ZDI",
"id": "CVE-2020-7555",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2021-31182",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202011-1559",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-185680",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-094"
},
{
"db": "CNVD",
"id": "CNVD-2021-31182"
},
{
"db": "VULHUB",
"id": "VHN-185680"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "NVD",
"id": "CVE-2020-7555"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1559"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. Interactive Graphical SCADA System (IGSS) Is Schneider Electric Software for monitoring and controlling control systems provided by the company. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of CGF files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated data structure. An attacker can leverage this vulnerability to execute code in the context of the current process. \n\r\n\r\nInteractive Graphical SCADA System 14.0.0.20247 and earlier versions have an out-of-bounds write vulnerability",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-7555"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "ZDI",
"id": "ZDI-21-094"
},
{
"db": "CNVD",
"id": "CNVD-2021-31182"
},
{
"db": "VULHUB",
"id": "VHN-185680"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-7555",
"trust": 3.8
},
{
"db": "ZDI",
"id": "ZDI-21-094",
"trust": 2.4
},
{
"db": "ICS CERT",
"id": "ICSA-20-324-04",
"trust": 2.0
},
{
"db": "SCHNEIDER",
"id": "SEVD-2020-315-03",
"trust": 1.7
},
{
"db": "JVN",
"id": "JVNVU99979220",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-11295",
"trust": 0.7
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1559",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2021-31182",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2020.4088",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-185680",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-094"
},
{
"db": "CNVD",
"id": "CNVD-2021-31182"
},
{
"db": "VULHUB",
"id": "VHN-185680"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "NVD",
"id": "CVE-2020-7555"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1559"
}
]
},
"id": "VAR-202011-1291",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31182"
},
{
"db": "VULHUB",
"id": "VHN-185680"
}
],
"trust": 1.6749999999999998
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31182"
}
]
},
"last_update_date": "2023-12-18T12:16:43.235000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Security Notification - Interactive Graphical SCADA System (IGSS)",
"trust": 0.8,
"url": "https://www.se.com/ww/en/download/document/sevd-2020-315-03"
},
{
"title": "IGSS Licensed Versions",
"trust": 0.8,
"url": "https://igss.schneider-electric.com/licensed-versions"
},
{
"title": "Schneider Electric has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://www.se.com/ww/en/download/document/sevd-2020-315-03/"
},
{
"title": "Patch for Schneider Electric Interactive Graphical SCADA System out-of-bounds write vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/261461"
},
{
"title": "Schneider Electric Interactive Graphical SCADA System Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=135150"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-094"
},
{
"db": "CNVD",
"id": "CNVD-2021-31182"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1559"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.9
},
{
"problemtype": "CWE-119",
"trust": 0.8
},
{
"problemtype": "CWE-125",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-185680"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "NVD",
"id": "CVE-2020-7555"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://www.se.com/ww/en/download/document/sevd-2020-315-03/"
},
{
"trust": 2.0,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-324-04"
},
{
"trust": 1.7,
"url": "https://www.zerodayinitiative.com/advisories/zdi-21-094/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7550"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7558"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7551"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7552"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7553"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7554"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7555"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7556"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7557"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu99979220"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.4088/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-7555"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-094"
},
{
"db": "CNVD",
"id": "CNVD-2021-31182"
},
{
"db": "VULHUB",
"id": "VHN-185680"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "NVD",
"id": "CVE-2020-7555"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1559"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-21-094"
},
{
"db": "CNVD",
"id": "CNVD-2021-31182"
},
{
"db": "VULHUB",
"id": "VHN-185680"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"db": "NVD",
"id": "CVE-2020-7555"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1559"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-01-29T00:00:00",
"db": "ZDI",
"id": "ZDI-21-094"
},
{
"date": "2021-04-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-31182"
},
{
"date": "2020-11-19T00:00:00",
"db": "VULHUB",
"id": "VHN-185680"
},
{
"date": "2020-11-19T08:46:47",
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"date": "2020-11-19T22:15:14.520000",
"db": "NVD",
"id": "CVE-2020-7555"
},
{
"date": "2020-11-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202011-1559"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-01-29T00:00:00",
"db": "ZDI",
"id": "ZDI-21-094"
},
{
"date": "2021-04-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-31182"
},
{
"date": "2021-01-30T00:00:00",
"db": "VULHUB",
"id": "VHN-185680"
},
{
"date": "2020-11-19T08:46:47",
"db": "JVNDB",
"id": "JVNDB-2020-009593"
},
{
"date": "2021-01-30T01:25:24.790000",
"db": "NVD",
"id": "CVE-2020-7555"
},
{
"date": "2021-02-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202011-1559"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202011-1559"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric Made Interactive Graphical SCADA System Multiple vulnerabilities in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009593"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202011-1559"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.