CVE-2020-5594 (GCVE-0-2020-5594)

Vulnerability from cvelistv5 – Published: 2020-06-23 07:35 – Updated: 2024-08-04 08:30
VLAI
Summary
Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors.
CWE
  • Cleartext Transmission of Sensitive Information
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:30:24.558Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-23T07:35:23.000Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2020-5594",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "all versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Mitsubishi Electric Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cleartext Transmission of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf",
              "refsource": "MISC",
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
            },
            {
              "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf",
              "refsource": "MISC",
              "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
            },
            {
              "name": "https://jvn.jp/en/vu/JVNVU91424496/index.html",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2020-5594",
    "datePublished": "2020-06-23T07:35:23.000Z",
    "dateReserved": "2020-01-06T00:00:00.000Z",
    "dateUpdated": "2024-08-04T08:30:24.558Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-5594",
      "date": "2026-09-23",
      "epss": "0.01296",
      "percentile": "0.69106"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-r_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0F2A20BD-77FE-42A3-9AC6-597470CD1212",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-r:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "71CC1A84-A51D-4E56-BA7A-9C1D21DDF8D1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-f_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1644AECC-4A04-4209-9654-668D6B3B093B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "175AA161-6775-4715-85A2-4AD426D131F5",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec-q_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1047B633-7FE4-47C2-846F-5878DA5D3038",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec-q:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "418EA7F6-FB8D-4192-8BEC-E34BBF98400A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec-l_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "93701E98-1A2C-45EE-933F-2FA9D803A875",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec-l:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FCADAD32-6840-45C7-94E1-DD7BE0A59417",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:mitsubishielectric:melsec-fx_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "25DCC54F-CA89-41BC-8C3F-89084911956D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:mitsubishielectric:melsec-fx:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "455C03F1-8A83-493D-9DAD-F7D0950105AF",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors."
        },
        {
          "lang": "es",
          "value": "Todos los m\u00f3dulos de CPU de las series Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L y FX, contienen una vulnerabilidad que permite la transmisi\u00f3n de informaci\u00f3n confidencial entre m\u00f3dulos de CPU y GX Works3 y/o GX Works2 por medio de vectores no especificados"
        }
      ],
      "id": "CVE-2020-5594",
      "lastModified": "2024-11-21T05:34:19.893",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-06-23T08:15:10.487",
      "references": [
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
        },
        {
          "source": "vultures@jpcert.or.jp",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
        }
      ],
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-319"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-r_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0F2A20BD-77FE-42A3-9AC6-597470CD1212",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-r:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "71CC1A84-A51D-4E56-BA7A-9C1D21DDF8D1",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-f_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1644AECC-4A04-4209-9654-668D6B3B093B",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-f:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "175AA161-6775-4715-85A2-4AD426D131F5",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mitsubishielectric:melsec-q_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1047B633-7FE4-47C2-846F-5878DA5D3038",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mitsubishielectric:melsec-q:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "418EA7F6-FB8D-4192-8BEC-E34BBF98400A",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mitsubishielectric:melsec-l_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "93701E98-1A2C-45EE-933F-2FA9D803A875",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mitsubishielectric:melsec-l:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FCADAD32-6840-45C7-94E1-DD7BE0A59417",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mitsubishielectric:melsec-fx_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "25DCC54F-CA89-41BC-8C3F-89084911956D",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mitsubishielectric:melsec-fx:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "455C03F1-8A83-493D-9DAD-F7D0950105AF",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors."
          },
          {
            "lang": "es",
            "value": "Todos los m\u00f3dulos de CPU de las series Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L y FX, contienen una vulnerabilidad que permite la transmisi\u00f3n de informaci\u00f3n confidencial entre m\u00f3dulos de CPU y GX Works3 y/o GX Works2 por medio de vectores no especificados"
          }
        ],
        "id": "CVE-2020-5594",
        "lastModified": "2024-11-21T05:34:19.893",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 6.4,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2020-06-23T08:15:10.487",
        "references": [
          {
            "source": "vultures@jpcert.or.jp",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
          },
          {
            "source": "vultures@jpcert.or.jp",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
          },
          {
            "source": "vultures@jpcert.or.jp",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf"
          }
        ],
        "sourceIdentifier": "vultures@jpcert.or.jp",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-319"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-22T17:42:50+00:00",
      "cve": "CVE-2020-5594",
      "id": "CVE-2020-5594",
      "initial_release_date": "2020-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2020-5594",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2020/cve-2020-5594.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…