Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JGS516PE before 2.6.0.48, JGS524Ev2 before 2.6.0.48, JGS524PE before 2.6.0.48, and GS116Ev2 before 2.6.0.48. A TFTP server was found to be active by default. It allows remote authenticated users to update the switch firmware.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:09:15.219Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062635/Security-Advisory-for-Security-Misconfiguration-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0376" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JGS516PE before 2.6.0.48, JGS524Ev2 before 2.6.0.48, JGS524PE before 2.6.0.48, and GS116Ev2 before 2.6.0.48. A TFTP server was found to be active by default. It allows remote authenticated users to update the switch firmware." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:L/I:H/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-16T19:20:50", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062635/Security-Advisory-for-Security-Misconfiguration-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0376" }, { "tags": [ "x_refsource_MISC" ], "url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35801", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JGS516PE before 2.6.0.48, JGS524Ev2 before 2.6.0.48, JGS524PE before 2.6.0.48, and GS116Ev2 before 2.6.0.48. A TFTP server was found to be active by default. It allows remote authenticated users to update the switch firmware." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:L/I:H/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062635/Security-Advisory-for-Security-Misconfiguration-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0376", "refsource": "MISC", "url": "https://kb.netgear.com/000062635/Security-Advisory-for-Security-Misconfiguration-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0376" }, { "name": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/", "refsource": "MISC", "url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35801", "datePublished": "2020-12-29T23:38:16", "dateReserved": "2020-12-29T00:00:00", "dateUpdated": "2024-08-04T17:09:15.219Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-35801\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-12-30T00:15:14.457\",\"lastModified\":\"2024-11-21T05:28:08.977\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JGS516PE before 2.6.0.48, JGS524Ev2 before 2.6.0.48, JGS524PE before 2.6.0.48, and GS116Ev2 before 2.6.0.48. A TFTP server was found to be active by default. It allows remote authenticated users to update the switch firmware.\"},{\"lang\":\"es\",\"value\":\"Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad.\u0026#xa0;Esto afecta a JGS516PE versiones anteriores a 2.6.0.48, JGS524Ev2 versiones anteriores a 2.6.0.48, JGS524PE versiones anteriores a 2.6.0.48 y GS116Ev2 versiones anteriores a 2.6.0.48. Se encontr\u00f3 un servidor TFTP activo por defecto. Permite a los usuarios remotos autentificados actualizar el firmware del switch\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H\",\"baseScore\":8.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.1,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:N/I:P/A:P\",\"baseScore\":5.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:jgs516pe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.0.48\",\"matchCriteriaId\":\"83FA56EB-35CD-4A58-8019-C4597AAC0104\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:jgs516pe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DCBC0DAB-226E-4C95-9818-7758D37EFD10\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:jgs524e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.0.48\",\"matchCriteriaId\":\"19D0AC3E-87B5-435A-B203-E9759A4A5396\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:jgs524e:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CFF899BD-AA1E-4C47-BCFD-5E32F75F538A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:jgs524pe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.0.48\",\"matchCriteriaId\":\"62D7F6C3-8104-4C7D-AE9D-8C96D40221A3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:jgs524pe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D4A32288-19B5-4A8F-B883-FCC326B7032D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:gs116e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.0.48\",\"matchCriteriaId\":\"9CCEFE31-BAA8-4791-BB66-27D341EAE6C7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:gs116e:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6DA5EF92-9B28-4C81-8A95-C5BCEC19591A\"}]}]}],\"references\":[{\"url\":\"https://kb.netgear.com/000062635/Security-Advisory-for-Security-Misconfiguration-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0376\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Not Applicable\"]},{\"url\":\"https://kb.netgear.com/000062635/Security-Advisory-for-Security-Misconfiguration-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0376\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Not Applicable\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.