Summary
Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, JGS524Ev2 before 2.6.0.48, JGS524PE before 2.6.0.48, and GS116Ev2 before 2.6.0.48. The TFTP firmware update mechanism does not properly implement firmware validations, allowing remote attackers to write arbitrary data to internal memory.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:09:15.186Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062636/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0378" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, JGS524Ev2 before 2.6.0.48, JGS524PE before 2.6.0.48, and GS116Ev2 before 2.6.0.48. The TFTP firmware update mechanism does not properly implement firmware validations, allowing remote attackers to write arbitrary data to internal memory." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:N/I:H/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-16T19:22:40", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062636/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0378" }, { "tags": [ "x_refsource_MISC" ], "url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35782", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, JGS524Ev2 before 2.6.0.48, JGS524PE before 2.6.0.48, and GS116Ev2 before 2.6.0.48. The TFTP firmware update mechanism does not properly implement firmware validations, allowing remote attackers to write arbitrary data to internal memory." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:N/I:H/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062636/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0378", "refsource": "MISC", "url": "https://kb.netgear.com/000062636/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0378" }, { "name": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/", "refsource": "MISC", "url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35782", "datePublished": "2020-12-29T23:41:12", "dateReserved": "2020-12-29T00:00:00", "dateUpdated": "2024-08-04T17:09:15.186Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-35782\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-12-30T00:15:13.207\",\"lastModified\":\"2024-11-21T05:28:04.850\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Certain NETGEAR devices are affected by lack of access control at the function level. This affects JGS516PE before 2.6.0.48, JGS524Ev2 before 2.6.0.48, JGS524PE before 2.6.0.48, and GS116Ev2 before 2.6.0.48. The TFTP firmware update mechanism does not properly implement firmware validations, allowing remote attackers to write arbitrary data to internal memory.\"},{\"lang\":\"es\",\"value\":\"Determinados dispositivos NETGEAR est\u00e1n afectados por una falta de control de acceso en el nivel de funci\u00f3n. Esto afecta a JGS516PE versiones anteriores a 2.6.0.48, JGS524Ev2 versiones anteriores a 2.6.0.48, JGS524PE versiones anteriores a 2.6.0.48 y GS116Ev2 versiones anteriores a 2.6.0.48. El mecanismo de actualizaci\u00f3n del firmware TFTP no implementa correctamente las validaciones del firmware, lo que permite a los atacantes remotos escribir datos arbitrarios en la memoria interna\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:L/Au:N/C:N/I:C/A:C\",\"baseScore\":7.8,\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":6.5,\"impactScore\":9.2,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:jgs516pe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.0.48\",\"matchCriteriaId\":\"83FA56EB-35CD-4A58-8019-C4597AAC0104\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:jgs516pe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DCBC0DAB-226E-4C95-9818-7758D37EFD10\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:jgs524e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.0.48\",\"matchCriteriaId\":\"19D0AC3E-87B5-435A-B203-E9759A4A5396\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:jgs524e:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CFF899BD-AA1E-4C47-BCFD-5E32F75F538A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:jgs524pe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.0.48\",\"matchCriteriaId\":\"62D7F6C3-8104-4C7D-AE9D-8C96D40221A3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:jgs524pe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D4A32288-19B5-4A8F-B883-FCC326B7032D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:gs116e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.0.48\",\"matchCriteriaId\":\"9CCEFE31-BAA8-4791-BB66-27D341EAE6C7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:gs116e:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6DA5EF92-9B28-4C81-8A95-C5BCEC19591A\"}]}]}],\"references\":[{\"url\":\"https://kb.netgear.com/000062636/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0378\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://kb.netgear.com/000062636/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0378\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.