cve-2020-12519
Vulnerability from cvelistv5
Published
2020-12-17 22:43
Modified
2024-09-17 01:21
Severity ?
EPSS score ?
Summary
On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use this vulnerability i.e. to open a reverse shell with root privileges.
References
▼ | URL | Tags | |
---|---|---|---|
info@cert.vde.com | https://cert.vde.com/en-us/advisories/vde-2020-049 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en-us/advisories/vde-2020-049 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Phoenix Contact | AXC F 1152 (1151412) |
Version: unspecified < 2021.0 LTS |
||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:56:52.098Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-049" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AXC F 1152 (1151412)", "vendor": "Phoenix Contact", "versions": [ { "lessThan": "2021.0 LTS", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "AXC F 2152 (2404267)", "vendor": "Phoenix Contact", "versions": [ { "lessThan": "2021.0 LTS", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "AXC F 3152 (1069208)", "vendor": "Phoenix Contact", "versions": [ { "lessThan": "2021.0 LTS", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "RFC 4072S (1051328", "vendor": "Phoenix Contact", "versions": [ { "lessThan": "2021.0 LTS", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "AXC F 2152 Starterkit (1046568)", "vendor": "Phoenix Contact", "versions": [ { "lessThan": "2021.0 LTS", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "PLCnext Technology Starterkit (1188165)", "vendor": "Phoenix Contact", "versions": [ { "lessThan": "2021.0 LTS", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Discovered by Patrick Muench, Torsten Loebner, Maurice Rothe, Pascal Keul and Daniel Hackel of SVA Systemvertrieb Alexander GmbH, coordinated by CERT@VDE" } ], "datePublic": "2020-12-17T00:00:00", "descriptions": [ { "lang": "en", "value": "On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use this vulnerability i.e. to open a reverse shell with root privileges." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-269", "description": "CWE-269 Improper Privilege Management", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-17T22:43:14", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-049" } ], "solutions": [ { "lang": "en", "value": "Phoenix Contact recommends affected users to upgrade to the current Firmware 2021.0 LTS or higher which fixes these vulnerabilities." } ], "source": { "advisory": "VDE-2020-049", "defect": [ "VDE-2020-049" ], "discovery": "EXTERNAL" }, "title": "Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: An attacker can use this vulnerability i.e. to open a reverse shell with root privileges.", "workarounds": [ { "lang": "en", "value": "Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note." } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "AKA": "", "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2020-12-17T09:00:00.000Z", "ID": "CVE-2020-12519", "STATE": "PUBLIC", "TITLE": "Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS: An attacker can use this vulnerability i.e. to open a reverse shell with root privileges." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "AXC F 1152 (1151412)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c", "version_name": "", "version_value": "2021.0 LTS" } ] } }, { "product_name": "AXC F 2152 (2404267)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c", "version_name": "", "version_value": "2021.0 LTS" } ] } }, { "product_name": "AXC F 3152 (1069208)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c", "version_name": "", "version_value": "2021.0 LTS" } ] } }, { "product_name": "RFC 4072S (1051328", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c", "version_name": "", "version_value": "2021.0 LTS" } ] } }, { "product_name": "AXC F 2152 Starterkit (1046568)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c", "version_name": "", "version_value": "2021.0 LTS" } ] } }, { "product_name": "PLCnext Technology Starterkit (1188165)", "version": { "version_data": [ { "platform": "", "version_affected": "\u003c", "version_name": "", "version_value": "2021.0 LTS" } ] } } ] }, "vendor_name": "Phoenix Contact" } ] } }, "configuration": [], "credit": [ { "lang": "eng", "value": "Discovered by Patrick Muench, Torsten Loebner, Maurice Rothe, Pascal Keul and Daniel Hackel of SVA Systemvertrieb Alexander GmbH, coordinated by CERT@VDE" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use this vulnerability i.e. to open a reverse shell with root privileges." } ] }, "exploit": [], "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-269 Improper Privilege Management" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en-us/advisories/vde-2020-049", "refsource": "CONFIRM", "url": "https://cert.vde.com/en-us/advisories/vde-2020-049" } ] }, "solution": [ { "lang": "en", "value": "Phoenix Contact recommends affected users to upgrade to the current Firmware 2021.0 LTS or higher which fixes these vulnerabilities." } ], "source": { "advisory": "VDE-2020-049", "defect": [ "VDE-2020-049" ], "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "value": "Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to the Phoenix Contact application note." } ] } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2020-12519", "datePublished": "2020-12-17T22:43:14.555150Z", "dateReserved": "2020-04-30T00:00:00", "dateUpdated": "2024-09-17T01:21:36.619Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-12519\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2020-12-17T23:15:13.060\",\"lastModified\":\"2024-11-21T04:59:51.313\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use this vulnerability i.e. to open a reverse shell with root privileges.\"},{\"lang\":\"es\",\"value\":\"En Phoenix Contact PLCnext Control Devices versiones anteriores a 2021.0 LTS, un atacante puede utilizar esta vulnerabilidad, es decir, para abrir un shell inverso con privilegios root\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.0,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*\",\"versionEndExcluding\":\"2021.0\",\"matchCriteriaId\":\"8233F8C3-5D10-4FD6-B192-39535B7B464C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:phoenixcontact:axc_f_1152:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A2474BD7-C447-4E07-A628-C729E376943D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*\",\"versionEndExcluding\":\"2021.0\",\"matchCriteriaId\":\"8233F8C3-5D10-4FD6-B192-39535B7B464C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:phoenixcontact:axc_f_2152:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AE2E6118-6587-444A-A143-9C3A1E6ED4FD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*\",\"versionEndExcluding\":\"2021.0\",\"matchCriteriaId\":\"8233F8C3-5D10-4FD6-B192-39535B7B464C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:phoenixcontact:axc_f_3152:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"57424998-4EAB-4682-BFC4-1D2A621514F4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*\",\"versionEndExcluding\":\"2021.0\",\"matchCriteriaId\":\"8233F8C3-5D10-4FD6-B192-39535B7B464C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:phoenixcontact:rfc_4072s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0BF1EAD1-7C19-4A6E-BF87-EF3F7E526BD6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*\",\"versionEndExcluding\":\"2021.0\",\"matchCriteriaId\":\"8233F8C3-5D10-4FD6-B192-39535B7B464C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:phoenixcontact:axc_f_2152_starterkit:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"079A104B-2016-4830-80C1-3AB969106649\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:phoenixcontact:plcnext_firmware:*:*:*:*:long_term_support:*:*:*\",\"versionEndExcluding\":\"2021.0\",\"matchCriteriaId\":\"8233F8C3-5D10-4FD6-B192-39535B7B464C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:phoenixcontact:plcnext_technology_starterkit:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"12BDD2FE-0D7C-4868-A5E4-B1004A5C217D\"}]}]}],\"references\":[{\"url\":\"https://cert.vde.com/en-us/advisories/vde-2020-049\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert.vde.com/en-us/advisories/vde-2020-049\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.