Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2019-6856
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2019-344-01 | Vendor Advisory | |
cybersecurity@se.com | https://www.us-cert.gov/ics/advisories/icsa-20-016-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2019-344-01 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-20-016-01 | Third Party Advisory, US Government Resource |
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric SE | Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) |
Version: Modicon M580 Version: Modicon M340 Version: Modicon Quantum Version: Modicon Premium (see security notification for specific versions) |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:31:04.415Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)", "vendor": "Schneider Electric SE", "versions": [ { "status": "affected", "version": "Modicon M580" }, { "status": "affected", "version": "Modicon M340" }, { "status": "affected", "version": "Modicon Quantum" }, { "status": "affected", "version": "Modicon Premium (see security notification for specific versions)" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-754", "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-01-21T23:04:36", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2019-6856", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)", "version": { "version_data": [ { "version_value": "Modicon M580" }, { "version_value": "Modicon M340" }, { "version_value": "Modicon Quantum" }, { "version_value": "Modicon Premium (see security notification for specific versions)" } ] } } ] }, "vendor_name": "Schneider Electric SE" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01", "refsource": "CONFIRM", "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2019-6856", "datePublished": "2020-01-06T22:57:02", "dateReserved": "2019-01-25T00:00:00", "dateUpdated": "2024-08-04T20:31:04.415Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-6856\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2020-01-06T23:15:11.317\",\"lastModified\":\"2024-11-21T04:47:17.430\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.\"},{\"lang\":\"es\",\"value\":\"CWE-754: existe una vulnerabilidad de Comprobaci\u00f3n Inapropiada de Condiciones Inusuales o Excepcionales en Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (v\u00e9ase la notificaci\u00f3n de seguridad para versiones espec\u00edficas) que podr\u00eda causar una Denegaci\u00f3n de Servicio cuando se escriben bloques de memoria f\u00edsica espec\u00edficos usando Modbus TCP.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.80\",\"matchCriteriaId\":\"6FDEB227-D50B-402C-9C11-E29F52BC10BB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E876C738-ABF6-4864-98A6-1E06E96A0DF4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.01\",\"matchCriteriaId\":\"606AFE88-8C9A-4D18-9209-1193B628669F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"138681A2-0146-492B-8E10-06849FC27C6E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxh5744m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"6F6FF401-ED15-45EE-9A84-171166BF4414\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxh5744m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8B57B894-5AA4-4412-B425-7338CB2FFA3C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxh5724m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"70CD95A2-9FAE-4A7E-8331-8904C0E0CE3D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxh5724m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C1F56BA4-6A19-44FB-8555-7360C77F83AF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp576634m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"E5EEE1F8-0DCA-4D18-A022-5DBE980F3A16\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp576634m_:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7F683564-419D-418B-A4D5-BB203F709DD7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp57554m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"ED646076-2294-4253-92BF-B95D5D5E87A4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp57554m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5572E616-5D86-46FF-AEA7-4A12E66F0ED4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp575634m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"98B1574C-2FC7-4A3C-B260-D8372A268F4A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp575634m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"57BF89C2-27F8-4FF5-9E4F-4F0CB6C2F0E9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp57454m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"853895C6-5EDF-4767-9653-F5F7826B4A7E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp57454m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC537593-1AB7-438E-AB71-EDB469A1DFF7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp574634m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"EC9FBA4C-DA99-4F22-9168-ECD281B090C3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp574634m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FE60505D-0211-4E8C-B32C-988E25698B1E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp57354m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"DD7766E8-40EB-4C72-8234-C8D997F98F6C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp57354m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FAE46047-D9AF-4720-A130-A0F989423F82\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp573634m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"C9246F10-84D1-4AE0-BF1A-B61EA1E965A2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp573634m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"80500883-2825-46DD-8ED9-4F324A4494CC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp57304m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"889586D3-B64F-42DA-8872-DD44C9790881\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp57304m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B5FDBAB3-C8C2-47F6-ACAA-B89BA53849B9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp57254m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"B6EBCADE-8F8C-402B-8FB6-62237168E788\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp57254m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"57B75D71-11CA-4DDF-849A-08A9D84C95AC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp572634m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"33E3F062-3874-4EB6-829B-285B428E982E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp572634m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EA2094F4-976F-44FA-A7E5-93E20A80DA00\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp57204m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"43BE3D1E-5F7D-409F-A932-073D5A566180\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp57204m_:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0E25651C-E4B5-47A2-A6CE-79F7ECAE246E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp571634m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"D1DEF9B5-6BC0-43A7-AD74-81F9D23BA843\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp571634m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"31A5DCC8-9E3D-4919-9DE3-73FC8733E73D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp57154m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"4E358F77-1F8F-4F2F-A54C-B5F2373EFEE6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp57154m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5CC8F0AB-C4A8-40B3-88E0-92F52EA05692\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tsxp57104m_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.20\",\"matchCriteriaId\":\"56724F0C-2DA8-4710-9D82-EE51FA9B062C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:tsxp57104m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"587226C6-6BE2-4A42-B593-34498F647B24\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:140cpu65150_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.52\",\"matchCriteriaId\":\"97C6F04E-FEF7-4DA4-A819-7E4C3DA173F9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:140cpu65150:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EC3E5496-C3D0-4DF4-A9AF-F227F889840E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:140cpu65160_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.52\",\"matchCriteriaId\":\"E9552C20-F295-4AB7-A44E-FB1072BAD1B3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:140cpu65160:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B2C2AF70-F0BB-4D17-901C-1FCBECDC44FB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:140cpu65260_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.52\",\"matchCriteriaId\":\"1BB8ACFC-C693-4C5A-B256-51FF0835FD69\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:140cpu65260:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3D7304B0-EE18-454B-B3F0-5EF387285D90\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:140cpu67261_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.52\",\"matchCriteriaId\":\"370F0F62-AA12-496B-8107-EEC24B070621\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:140cpu67261:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"164AEEA1-666F-428A-BFCB-5DEEEFE1D771\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:140cpu67060_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.52\",\"matchCriteriaId\":\"06F31148-8213-4B01-AA48-D9D7C515E38A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:140cpu67060:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8AF2A7A3-89EF-480D-8E6E-20E11CF60A97\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:140cpu67160_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.52\",\"matchCriteriaId\":\"D6E3B57D-062A-431D-B96F-28463DE757DF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:140cpu67160:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3870E952-7A32-43DA-8C66-DE43C862639B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:140cpu67261_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.52\",\"matchCriteriaId\":\"370F0F62-AA12-496B-8107-EEC24B070621\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:140cpu67261:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"164AEEA1-666F-428A-BFCB-5DEEEFE1D771\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:140cpu67260_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.52\",\"matchCriteriaId\":\"108BA75E-B7B4-4A51-9DB8-B928154DD51A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:140cpu67260:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C9E4FCBA-4980-4C8F-A185-5E9C4CF9E8B5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:140cpu65860_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.52\",\"matchCriteriaId\":\"C4D81FBC-7C66-4367-8A0F-7F96C09A56A4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:140cpu65860:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9B8230FD-0C0A-467C-9BAD-09257739D462\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:140cpu67861_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.52\",\"matchCriteriaId\":\"4419CB2D-AABC-4F77-9C75-42ABA62CBA6B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:140cpu67861:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CF97B5A6-960F-42BA-A397-09C819A3200C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:140cpu65160s_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.52\",\"matchCriteriaId\":\"D793BE48-1025-4C6C-8E7D-82E013DDDE5D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:140cpu65160s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"95E48F27-F241-4491-AFF7-8BD562F21A52\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:140cpu67160s_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.52\",\"matchCriteriaId\":\"41654852-0E58-46CC-A734-F59FE9B83990\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:140cpu67160s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"71C1C17A-9111-49B8-A2CE-3A2FB87616F1\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2019-344-01\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-016-01\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2019-344-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-016-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
var-202001-0449
Vulnerability from variot
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP. plural Modicon The product contains an exceptional condition checking vulnerability.Denial of service (DoS) May be in a state. Schneider Electric Modicon M580 and other products are from Schneider Electric (France). Schneider Electric Modicon M580 is a programmable automation controller. Schneider Electric Modicon Premium is a large programmable logic controller (PLC) for discrete or process applications. Schneider Electric Modicon Quantum is a large programmable logic controller (PLC) for process applications, high availability and safety solutions.
Several Schneider Electric products have code issue vulnerabilities that originate from programs that do not properly check for abnormal conditions. An attacker could use this vulnerability to cause a denial of service
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202001-0449", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "tsxp573634m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "tsxp57554m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "140cpu65150", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.52" }, { "model": "tsxp57204m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "tsxp57454m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "tsxp57304m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "tsxp572634m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "140cpu65260", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.52" }, { "model": "140cpu67160", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.52" }, { "model": "tsxp57354m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "140cpu67861", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.52" }, { "model": "140cpu67060", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.52" }, { "model": "140cpu67160s", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.52" }, { "model": "tsxp576634m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "tsxh5724m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "tsxp571634m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "modicon m340", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.01" }, { "model": "tsxp57104m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "tsxp574634m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "140cpu65860", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.52" }, { "model": "140cpu67261", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.52" }, { "model": "modicon m580", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "2.80" }, { "model": "tsxh5744m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "140cpu65160s", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.52" }, { "model": "tsxp57154m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "140cpu65160", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.52" }, { "model": "140cpu67260", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.52" }, { "model": "tsxp57254m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "tsxp575634m", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "3.20" }, { "model": "modicon m340", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "modicon m580", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "tsxh5724m", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "tsxh5744m", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "tsxp57354m", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "tsxp57454m", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "tsxp574634m", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "tsxp57554m", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "tsxp575634m", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "tsxp576634m", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "electric modicon m340", "scope": "lt", "trust": 0.6, "vendor": "schneider", "version": "3.01" }, { "model": "electric modicon m580", "scope": "lt", "trust": 0.6, "vendor": "schneider", "version": "2.80" }, { "model": "electric modicon premium", "scope": "lt", "trust": 0.6, "vendor": "schneider", "version": "3.20" }, { "model": "electric modicon quantum", "scope": "lt", "trust": 0.6, "vendor": "schneider", "version": "3.52" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-02578" }, { "db": "JVNDB", "id": "JVNDB-2019-014057" }, { "db": "NVD", "id": "CVE-2019-6856" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:schneider_electric:modicon_m340_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:schneider_electric:modicon_m580_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:schneider_electric:tsxh5724m_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:schneider_electric:tsxh5744m_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:schneider_electric:tsxp57354m_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:schneider_electric:tsxp57454m_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:schneider_electric:tsxp574634m_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:schneider_electric:tsxp57554m_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:schneider_electric:tsxp575634m_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:schneider_electric:tsxp576634m_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-014057" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Chansim Deng", "sources": [ { "db": "CNNVD", "id": "CNNVD-201912-834" } ], "trust": 0.6 }, "cve": "CVE-2019-6856", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2019-6856", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2020-02578", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2019-6856", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2019-6856", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-6856", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2019-6856", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2020-02578", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201912-834", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-02578" }, { "db": "JVNDB", "id": "JVNDB-2019-014057" }, { "db": "CNNVD", "id": "CNNVD-201912-834" }, { "db": "NVD", "id": "CVE-2019-6856" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP. plural Modicon The product contains an exceptional condition checking vulnerability.Denial of service (DoS) May be in a state. Schneider Electric Modicon M580 and other products are from Schneider Electric (France). Schneider Electric Modicon M580 is a programmable automation controller. Schneider Electric Modicon Premium is a large programmable logic controller (PLC) for discrete or process applications. Schneider Electric Modicon Quantum is a large programmable logic controller (PLC) for process applications, high availability and safety solutions. \n\nSeveral Schneider Electric products have code issue vulnerabilities that originate from programs that do not properly check for abnormal conditions. An attacker could use this vulnerability to cause a denial of service", "sources": [ { "db": "NVD", "id": "CVE-2019-6856" }, { "db": "JVNDB", "id": "JVNDB-2019-014057" }, { "db": "CNVD", "id": "CNVD-2020-02578" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-6856", "trust": 3.0 }, { "db": "ICS CERT", "id": "ICSA-20-016-01", "trust": 2.4 }, { "db": "SCHNEIDER", "id": "SEVD-2019-344-01", "trust": 1.6 }, { "db": "JVNDB", "id": "JVNDB-2019-014057", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2020-02578", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.0189", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-201912-834", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-02578" }, { "db": "JVNDB", "id": "JVNDB-2019-014057" }, { "db": "CNNVD", "id": "CNNVD-201912-834" }, { "db": "NVD", "id": "CVE-2019-6856" } ] }, "id": "VAR-202001-0449", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-02578" } ], "trust": 1.5935065 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-02578" } ] }, "last_update_date": "2024-11-23T21:36:14.626000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SEVD-2019-344-01", "trust": 0.8, "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01/" }, { "title": "Patch for Multiple Schneider Electric Product Code Issue Vulnerabilities (CNVD-2020-02578)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/197257" }, { "title": "Multiple Schneider Electric Product code issue vulnerability fixes", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=106371" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-02578" }, { "db": "JVNDB", "id": "JVNDB-2019-014057" }, { "db": "CNNVD", "id": "CNNVD-201912-834" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-754", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-014057" }, { "db": "NVD", "id": "CVE-2019-6856" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01" }, { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6856" }, { "trust": 1.6, "url": "https://www.se.com/ww/en/download/document/sevd-2019-344-01" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6856" }, { "trust": 0.6, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18615" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.0189/" }, { "trust": 0.6, "url": "https://www.se.com/ww/en/download/document/sevd-2019-344-01/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-02578" }, { "db": "JVNDB", "id": "JVNDB-2019-014057" }, { "db": "CNNVD", "id": "CNNVD-201912-834" }, { "db": "NVD", "id": "CVE-2019-6856" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-02578" }, { "db": "JVNDB", "id": "JVNDB-2019-014057" }, { "db": "CNNVD", "id": "CNNVD-201912-834" }, { "db": "NVD", "id": "CVE-2019-6856" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-01-16T00:00:00", "db": "CNVD", "id": "CNVD-2020-02578" }, { "date": "2020-01-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-014057" }, { "date": "2019-12-10T00:00:00", "db": "CNNVD", "id": "CNNVD-201912-834" }, { "date": "2020-01-06T23:15:11.317000", "db": "NVD", "id": "CVE-2019-6856" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-01-17T00:00:00", "db": "CNVD", "id": "CNVD-2020-02578" }, { "date": "2020-01-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-014057" }, { "date": "2022-03-10T00:00:00", "db": "CNNVD", "id": "CNNVD-201912-834" }, { "date": "2024-11-21T04:47:17.430000", "db": "NVD", "id": "CVE-2019-6856" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201912-834" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Modicon Vulnerability in checking exceptional conditions in products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-014057" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "code problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-201912-834" } ], "trust": 0.6 } }
icsa-20-016-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Younes Dragoni" ], "organization": "Nozomi Networks", "summary": "reporting this vulnerability to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could result in a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Commercial Facilities, Critical Manufacturing, and Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "France", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-20-016-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-016-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-20-016-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-016-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Schneider Electric Modicon Controllers (Update A)", "tracking": { "current_release_date": "2020-03-31T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-20-016-01", "initial_release_date": "2020-01-16T00:00:00.000000Z", "revision_history": [ { "date": "2020-01-16T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-20-016-01 Schneider Electric Modicon Controllers" }, { "date": "2020-03-31T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-20-016-01 Schneider Electric Modicon Controllers (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 3.20", "product": { "name": "Modicon Premium: all versions prior to v3.20", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Modicon Premium" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 3.60", "product": { "name": "Modicon Quantum: all versions prior to v3.60", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Modicon Quantum" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 3.52", "product": { "name": "Modicon Quantum: all versions prior to v3.52", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Modicon Quantum" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 2.80", "product": { "name": "Modicon M580: all versions prior to v2.80", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Modicon M580" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 3.01", "product": { "name": "Modicon M340: all versions prior to v3.01", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "Modicon M340" } ], "category": "vendor", "name": "Schneider Electric Software, LLC" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-6857", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "This vulnerability could cause a denial-of-service condition in the controller when reading specific memory blocks using Modbus TCP.CVE-2019-6857 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6857" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "BMEP584040: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040_SV3.10/" }, { "category": "mitigation", "details": "BMEH584040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040_SV3.10/" }, { "category": "mitigation", "details": "BMEP586040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP586040_SV3.10/" }, { "category": "mitigation", "details": "BMEH586040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH586040_SV3.10/" }, { "category": "mitigation", "details": "BMEP581020 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP581020_SV3.10/" }, { "category": "mitigation", "details": "BMEP582020 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582020_SV3.10/" }, { "category": "mitigation", "details": "BMEP582040 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582040_SV3.10/" }, { "category": "mitigation", "details": "BMEP583020: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP583020_SV3.10/" }, { "category": "mitigation", "details": "BMEP583040: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP583040_SV3.10/" }, { "category": "mitigation", "details": "BMEP584020: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584020_SV3.10/" }, { "category": "mitigation", "details": "BMEP585040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP585040_SV3.10/" }, { "category": "mitigation", "details": "BMEH582040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH582040_SV3.10/" }, { "category": "mitigation", "details": "BMEP584040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040S_SV3.10/" }, { "category": "mitigation", "details": "BMEH584040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH584040S_SV3.10/" }, { "category": "mitigation", "details": "BMEH586040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH586040S_SV3.10/" }, { "category": "mitigation", "details": "BMEP582040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582040S_SV3.10/" }, { "category": "vendor_fix", "details": "BMXP3420302 and CL and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420302_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP342020 and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP342020_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP342000: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP342000_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP341000 and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP341000_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP3420102 and CL: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420102_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP3420302: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420302_Firmwares/" }, { "category": "mitigation", "details": "Modicon Premium v3.20 firmware is available by contacting Schneider Electric customer support.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "140CPU65150 [C] and 140CPU65160 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU651X0_SV3.60" }, { "category": "mitigation", "details": "140CPU65260 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU65260_SV3.60" }, { "category": "mitigation", "details": "140CPU67261 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67261_SV3.60" }, { "category": "mitigation", "details": "140CPU67060 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67060_SV3.60" }, { "category": "mitigation", "details": "140CPU67160 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67160_SV3.60" }, { "category": "mitigation", "details": "140CPU67260 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67260_SV3.60" }, { "category": "mitigation", "details": "140CPU65860 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU65860_SV3.60" }, { "category": "mitigation", "details": "140CPU67861 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67861_SV3.60" }, { "category": "mitigation", "details": "140CPU65160S: Please contact Schneider Electric customer support to get the Quantum v3.60 firmware", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "140CPU67160S: Please contact Schneider Electric customer support to get the Quantum v3.60 firmware", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Physical controls should be in place so that no unauthorized person would have access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for which the devices are intended.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., should be scanned before use in the terminals or any node connected to these networks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "For more information on this vulnerability and the associated upgrade, please see Schneider Electric\u0027s SEVD-2019-344-01", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-344-01/" }, { "category": "mitigation", "details": "For more details and assistance on how to protect during installation, please contact a Schneider Electric representative and/or Schneider Electric Industrial Cybersecurity Services. These organizations are aware of this situation and can support you through the process.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2019-6856", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "This vulnerability could cause a denial-of-service condition when writing specific physical memory blocks using Modbus TCP.CVE-2019-6856 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6856" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "BMEP584040: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040_SV3.10/" }, { "category": "mitigation", "details": "BMEH584040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040_SV3.10/" }, { "category": "mitigation", "details": "BMEP586040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP586040_SV3.10/" }, { "category": "mitigation", "details": "BMEH586040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH586040_SV3.10/" }, { "category": "mitigation", "details": "BMEP581020 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP581020_SV3.10/" }, { "category": "mitigation", "details": "BMEP582020 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582020_SV3.10/" }, { "category": "mitigation", "details": "BMEP582040 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582040_SV3.10/" }, { "category": "mitigation", "details": "BMEP583020: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP583020_SV3.10/" }, { "category": "mitigation", "details": "BMEP583040: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP583040_SV3.10/" }, { "category": "mitigation", "details": "BMEP584020: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584020_SV3.10/" }, { "category": "mitigation", "details": "BMEP585040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP585040_SV3.10/" }, { "category": "mitigation", "details": "BMEH582040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH582040_SV3.10/" }, { "category": "mitigation", "details": "BMEP584040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040S_SV3.10/" }, { "category": "mitigation", "details": "BMEH584040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH584040S_SV3.10/" }, { "category": "mitigation", "details": "BMEH586040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH586040S_SV3.10/" }, { "category": "mitigation", "details": "BMEP582040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582040S_SV3.10/" }, { "category": "vendor_fix", "details": "BMXP3420302 and CL and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420302_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP342020 and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP342020_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP342000: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP342000_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP341000 and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP341000_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP3420102 and CL: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420102_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP3420302: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420302_Firmwares/" }, { "category": "mitigation", "details": "Modicon Premium v3.20 firmware is available by contacting Schneider Electric customer support.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "140CPU65150 [C] and 140CPU65160 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU651X0_SV3.60" }, { "category": "mitigation", "details": "140CPU65260 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU65260_SV3.60" }, { "category": "mitigation", "details": "140CPU67261 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67261_SV3.60" }, { "category": "mitigation", "details": "140CPU67060 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67060_SV3.60" }, { "category": "mitigation", "details": "140CPU67160 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67160_SV3.60" }, { "category": "mitigation", "details": "140CPU67260 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67260_SV3.60" }, { "category": "mitigation", "details": "140CPU65860 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU65860_SV3.60" }, { "category": "mitigation", "details": "140CPU67861 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67861_SV3.60" }, { "category": "mitigation", "details": "140CPU65160S: Please contact Schneider Electric customer support to get the Quantum v3.60 firmware", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "140CPU67160S: Please contact Schneider Electric customer support to get the Quantum v3.60 firmware", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Physical controls should be in place so that no unauthorized person would have access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for which the devices are intended.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., should be scanned before use in the terminals or any node connected to these networks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "For more information on this vulnerability and the associated upgrade, please see Schneider Electric\u0027s SEVD-2019-344-01", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-344-01/" }, { "category": "mitigation", "details": "For more details and assistance on how to protect during installation, please contact a Schneider Electric representative and/or Schneider Electric Industrial Cybersecurity Services. These organizations are aware of this situation and can support you through the process.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2018-7794", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "This vulnerability could cause a denial-of-service condition when reading data with invalid index using Modbus TCP. CVE-2018-7794 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is(AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).. --------- End Update A Part 1 of 1 ---------CVE-2018-7794 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is(AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7794" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "BMEP584040: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040_SV3.10/" }, { "category": "mitigation", "details": "BMEH584040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040_SV3.10/" }, { "category": "mitigation", "details": "BMEP586040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP586040_SV3.10/" }, { "category": "mitigation", "details": "BMEH586040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH586040_SV3.10/" }, { "category": "mitigation", "details": "BMEP581020 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP581020_SV3.10/" }, { "category": "mitigation", "details": "BMEP582020 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582020_SV3.10/" }, { "category": "mitigation", "details": "BMEP582040 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582040_SV3.10/" }, { "category": "mitigation", "details": "BMEP583020: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP583020_SV3.10/" }, { "category": "mitigation", "details": "BMEP583040: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP583040_SV3.10/" }, { "category": "mitigation", "details": "BMEP584020: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584020_SV3.10/" }, { "category": "mitigation", "details": "BMEP585040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP585040_SV3.10/" }, { "category": "mitigation", "details": "BMEH582040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH582040_SV3.10/" }, { "category": "mitigation", "details": "BMEP584040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040S_SV3.10/" }, { "category": "mitigation", "details": "BMEH584040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH584040S_SV3.10/" }, { "category": "mitigation", "details": "BMEH586040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH586040S_SV3.10/" }, { "category": "mitigation", "details": "BMEP582040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582040S_SV3.10/" }, { "category": "vendor_fix", "details": "BMXP3420302 and CL and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420302_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP342020 and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP342020_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP342000: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP342000_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP341000 and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP341000_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP3420102 and CL: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420102_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP3420302: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420302_Firmwares/" }, { "category": "mitigation", "details": "Modicon Premium v3.20 firmware is available by contacting Schneider Electric customer support.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "140CPU65150 [C] and 140CPU65160 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU651X0_SV3.60" }, { "category": "mitigation", "details": "140CPU65260 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU65260_SV3.60" }, { "category": "mitigation", "details": "140CPU67261 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67261_SV3.60" }, { "category": "mitigation", "details": "140CPU67060 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67060_SV3.60" }, { "category": "mitigation", "details": "140CPU67160 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67160_SV3.60" }, { "category": "mitigation", "details": "140CPU67260 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67260_SV3.60" }, { "category": "mitigation", "details": "140CPU65860 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU65860_SV3.60" }, { "category": "mitigation", "details": "140CPU67861 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67861_SV3.60" }, { "category": "mitigation", "details": "140CPU65160S: Please contact Schneider Electric customer support to get the Quantum v3.60 firmware", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "140CPU67160S: Please contact Schneider Electric customer support to get the Quantum v3.60 firmware", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Physical controls should be in place so that no unauthorized person would have access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for which the devices are intended.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., should be scanned before use in the terminals or any node connected to these networks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "For more information on this vulnerability and the associated upgrade, please see Schneider Electric\u0027s SEVD-2019-344-01", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-344-01/" }, { "category": "mitigation", "details": "For more details and assistance on how to protect during installation, please contact a Schneider Electric representative and/or Schneider Electric Industrial Cybersecurity Services. These organizations are aware of this situation and can support you through the process.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] } ] }
ICSA-20-016-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Younes Dragoni" ], "organization": "Nozomi Networks", "summary": "reporting this vulnerability to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could result in a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Commercial Facilities, Critical Manufacturing, and Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "France", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-20-016-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-016-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-20-016-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-016-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Schneider Electric Modicon Controllers (Update A)", "tracking": { "current_release_date": "2020-03-31T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-20-016-01", "initial_release_date": "2020-01-16T00:00:00.000000Z", "revision_history": [ { "date": "2020-01-16T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-20-016-01 Schneider Electric Modicon Controllers" }, { "date": "2020-03-31T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-20-016-01 Schneider Electric Modicon Controllers (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 3.20", "product": { "name": "Modicon Premium: all versions prior to v3.20", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Modicon Premium" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 3.60", "product": { "name": "Modicon Quantum: all versions prior to v3.60", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Modicon Quantum" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 3.52", "product": { "name": "Modicon Quantum: all versions prior to v3.52", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Modicon Quantum" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 2.80", "product": { "name": "Modicon M580: all versions prior to v2.80", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Modicon M580" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 3.01", "product": { "name": "Modicon M340: all versions prior to v3.01", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "Modicon M340" } ], "category": "vendor", "name": "Schneider Electric Software, LLC" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-6857", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "This vulnerability could cause a denial-of-service condition in the controller when reading specific memory blocks using Modbus TCP.CVE-2019-6857 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6857" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "BMEP584040: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040_SV3.10/" }, { "category": "mitigation", "details": "BMEH584040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040_SV3.10/" }, { "category": "mitigation", "details": "BMEP586040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP586040_SV3.10/" }, { "category": "mitigation", "details": "BMEH586040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH586040_SV3.10/" }, { "category": "mitigation", "details": "BMEP581020 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP581020_SV3.10/" }, { "category": "mitigation", "details": "BMEP582020 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582020_SV3.10/" }, { "category": "mitigation", "details": "BMEP582040 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582040_SV3.10/" }, { "category": "mitigation", "details": "BMEP583020: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP583020_SV3.10/" }, { "category": "mitigation", "details": "BMEP583040: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP583040_SV3.10/" }, { "category": "mitigation", "details": "BMEP584020: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584020_SV3.10/" }, { "category": "mitigation", "details": "BMEP585040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP585040_SV3.10/" }, { "category": "mitigation", "details": "BMEH582040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH582040_SV3.10/" }, { "category": "mitigation", "details": "BMEP584040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040S_SV3.10/" }, { "category": "mitigation", "details": "BMEH584040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH584040S_SV3.10/" }, { "category": "mitigation", "details": "BMEH586040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH586040S_SV3.10/" }, { "category": "mitigation", "details": "BMEP582040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582040S_SV3.10/" }, { "category": "vendor_fix", "details": "BMXP3420302 and CL and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420302_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP342020 and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP342020_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP342000: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP342000_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP341000 and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP341000_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP3420102 and CL: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420102_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP3420302: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420302_Firmwares/" }, { "category": "mitigation", "details": "Modicon Premium v3.20 firmware is available by contacting Schneider Electric customer support.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "140CPU65150 [C] and 140CPU65160 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU651X0_SV3.60" }, { "category": "mitigation", "details": "140CPU65260 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU65260_SV3.60" }, { "category": "mitigation", "details": "140CPU67261 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67261_SV3.60" }, { "category": "mitigation", "details": "140CPU67060 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67060_SV3.60" }, { "category": "mitigation", "details": "140CPU67160 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67160_SV3.60" }, { "category": "mitigation", "details": "140CPU67260 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67260_SV3.60" }, { "category": "mitigation", "details": "140CPU65860 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU65860_SV3.60" }, { "category": "mitigation", "details": "140CPU67861 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67861_SV3.60" }, { "category": "mitigation", "details": "140CPU65160S: Please contact Schneider Electric customer support to get the Quantum v3.60 firmware", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "140CPU67160S: Please contact Schneider Electric customer support to get the Quantum v3.60 firmware", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Physical controls should be in place so that no unauthorized person would have access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for which the devices are intended.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., should be scanned before use in the terminals or any node connected to these networks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "For more information on this vulnerability and the associated upgrade, please see Schneider Electric\u0027s SEVD-2019-344-01", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-344-01/" }, { "category": "mitigation", "details": "For more details and assistance on how to protect during installation, please contact a Schneider Electric representative and/or Schneider Electric Industrial Cybersecurity Services. These organizations are aware of this situation and can support you through the process.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2019-6856", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "This vulnerability could cause a denial-of-service condition when writing specific physical memory blocks using Modbus TCP.CVE-2019-6856 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6856" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "BMEP584040: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040_SV3.10/" }, { "category": "mitigation", "details": "BMEH584040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040_SV3.10/" }, { "category": "mitigation", "details": "BMEP586040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP586040_SV3.10/" }, { "category": "mitigation", "details": "BMEH586040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH586040_SV3.10/" }, { "category": "mitigation", "details": "BMEP581020 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP581020_SV3.10/" }, { "category": "mitigation", "details": "BMEP582020 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582020_SV3.10/" }, { "category": "mitigation", "details": "BMEP582040 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582040_SV3.10/" }, { "category": "mitigation", "details": "BMEP583020: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP583020_SV3.10/" }, { "category": "mitigation", "details": "BMEP583040: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP583040_SV3.10/" }, { "category": "mitigation", "details": "BMEP584020: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584020_SV3.10/" }, { "category": "mitigation", "details": "BMEP585040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP585040_SV3.10/" }, { "category": "mitigation", "details": "BMEH582040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH582040_SV3.10/" }, { "category": "mitigation", "details": "BMEP584040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040S_SV3.10/" }, { "category": "mitigation", "details": "BMEH584040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH584040S_SV3.10/" }, { "category": "mitigation", "details": "BMEH586040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH586040S_SV3.10/" }, { "category": "mitigation", "details": "BMEP582040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582040S_SV3.10/" }, { "category": "vendor_fix", "details": "BMXP3420302 and CL and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420302_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP342020 and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP342020_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP342000: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP342000_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP341000 and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP341000_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP3420102 and CL: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420102_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP3420302: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420302_Firmwares/" }, { "category": "mitigation", "details": "Modicon Premium v3.20 firmware is available by contacting Schneider Electric customer support.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "140CPU65150 [C] and 140CPU65160 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU651X0_SV3.60" }, { "category": "mitigation", "details": "140CPU65260 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU65260_SV3.60" }, { "category": "mitigation", "details": "140CPU67261 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67261_SV3.60" }, { "category": "mitigation", "details": "140CPU67060 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67060_SV3.60" }, { "category": "mitigation", "details": "140CPU67160 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67160_SV3.60" }, { "category": "mitigation", "details": "140CPU67260 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67260_SV3.60" }, { "category": "mitigation", "details": "140CPU65860 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU65860_SV3.60" }, { "category": "mitigation", "details": "140CPU67861 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67861_SV3.60" }, { "category": "mitigation", "details": "140CPU65160S: Please contact Schneider Electric customer support to get the Quantum v3.60 firmware", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "140CPU67160S: Please contact Schneider Electric customer support to get the Quantum v3.60 firmware", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Physical controls should be in place so that no unauthorized person would have access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for which the devices are intended.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., should be scanned before use in the terminals or any node connected to these networks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "For more information on this vulnerability and the associated upgrade, please see Schneider Electric\u0027s SEVD-2019-344-01", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-344-01/" }, { "category": "mitigation", "details": "For more details and assistance on how to protect during installation, please contact a Schneider Electric representative and/or Schneider Electric Industrial Cybersecurity Services. These organizations are aware of this situation and can support you through the process.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] }, { "cve": "CVE-2018-7794", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "This vulnerability could cause a denial-of-service condition when reading data with invalid index using Modbus TCP. CVE-2018-7794 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is(AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).. --------- End Update A Part 1 of 1 ---------CVE-2018-7794 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is(AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7794" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "BMEP584040: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040_SV3.10/" }, { "category": "mitigation", "details": "BMEH584040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040_SV3.10/" }, { "category": "mitigation", "details": "BMEP586040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP586040_SV3.10/" }, { "category": "mitigation", "details": "BMEH586040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH586040_SV3.10/" }, { "category": "mitigation", "details": "BMEP581020 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP581020_SV3.10/" }, { "category": "mitigation", "details": "BMEP582020 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582020_SV3.10/" }, { "category": "mitigation", "details": "BMEP582040 and H: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582040_SV3.10/" }, { "category": "mitigation", "details": "BMEP583020: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP583020_SV3.10/" }, { "category": "mitigation", "details": "BMEP583040: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP583040_SV3.10/" }, { "category": "mitigation", "details": "BMEP584020: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584020_SV3.10/" }, { "category": "mitigation", "details": "BMEP585040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP585040_SV3.10/" }, { "category": "mitigation", "details": "BMEH582040 and C: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH582040_SV3.10/" }, { "category": "mitigation", "details": "BMEP584040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP584040S_SV3.10/" }, { "category": "mitigation", "details": "BMEH584040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH584040S_SV3.10/" }, { "category": "mitigation", "details": "BMEH586040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEH586040S_SV3.10/" }, { "category": "mitigation", "details": "BMEP582040S: Specific Modicon M580 firmware v3.10", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/M580_BMEP582040S_SV3.10/" }, { "category": "vendor_fix", "details": "BMXP3420302 and CL and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420302_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP342020 and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP342020_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP342000: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP342000_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP341000 and H: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP341000_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP3420102 and CL: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420102_Firmwares/" }, { "category": "vendor_fix", "details": "BMXP3420302: Modicon M340 firmware v3.20", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/BMXP3420302_Firmwares/" }, { "category": "mitigation", "details": "Modicon Premium v3.20 firmware is available by contacting Schneider Electric customer support.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "140CPU65150 [C] and 140CPU65160 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU651X0_SV3.60" }, { "category": "mitigation", "details": "140CPU65260 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU65260_SV3.60" }, { "category": "mitigation", "details": "140CPU67261 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67261_SV3.60" }, { "category": "mitigation", "details": "140CPU67060 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67060_SV3.60" }, { "category": "mitigation", "details": "140CPU67160 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67160_SV3.60" }, { "category": "mitigation", "details": "140CPU67260 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67260_SV3.60" }, { "category": "mitigation", "details": "140CPU65860 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU65860_SV3.60" }, { "category": "mitigation", "details": "140CPU67861 [C]: Modicon Quantum firmware v3.60", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/Quantum_140CPU67861_SV3.60" }, { "category": "mitigation", "details": "140CPU65160S: Please contact Schneider Electric customer support to get the Quantum v3.60 firmware", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "140CPU67160S: Please contact Schneider Electric customer support to get the Quantum v3.60 firmware", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Physical controls should be in place so that no unauthorized person would have access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for which the devices are intended.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "All methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., should be scanned before use in the terminals or any node connected to these networks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "For more information on this vulnerability and the associated upgrade, please see Schneider Electric\u0027s SEVD-2019-344-01", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-344-01/" }, { "category": "mitigation", "details": "For more details and assistance on how to protect during installation, please contact a Schneider Electric representative and/or Schneider Electric Industrial Cybersecurity Services. These organizations are aware of this situation and can support you through the process.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] } ] }
gsd-2019-6856
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2019-6856", "description": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.", "id": "GSD-2019-6856" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-6856" ], "details": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.", "id": "GSD-2019-6856", "modified": "2023-12-13T01:23:49.479421Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2019-6856", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)", "version": { "version_data": [ { "version_value": "Modicon M580" }, { "version_value": "Modicon M340" }, { "version_value": "Modicon Quantum" }, { "version_value": "Modicon Premium (see security notification for specific versions)" } ] } } ] }, "vendor_name": "Schneider Electric SE" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01", "refsource": "CONFIRM", "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.01", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxh5744m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxh5744m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxh5724m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxh5724m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp576634m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp576634m_:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp57554m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp57554m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp575634m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp575634m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp57454m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp57454m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp574634m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp574634m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp57354m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp57354m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp573634m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp573634m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp57304m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp57304m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp57254m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp57254m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp572634m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp572634m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp57204m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp57204m_:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp571634m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp571634m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp57154m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp57154m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:tsxp57104m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:tsxp57104m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:140cpu65150_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:140cpu65150:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:140cpu65160_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:140cpu65160:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:140cpu65260_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:140cpu65260:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:140cpu67261_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:140cpu67261:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:140cpu67060_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:140cpu67060:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:140cpu67160_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:140cpu67160:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:140cpu67261_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:140cpu67261:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:140cpu67260_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:140cpu67260:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:140cpu65860_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:140cpu65860:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:140cpu67861_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:140cpu67861:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:140cpu65160s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:140cpu65160s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:schneider-electric:140cpu67160s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:140cpu67160s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2019-6856" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-754" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01", "refsource": "MISC", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2022-02-03T15:18Z", "publishedDate": "2020-01-06T23:15Z" } } }
fkie_cve-2019-6856
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2019-344-01 | Vendor Advisory | |
cybersecurity@se.com | https://www.us-cert.gov/ics/advisories/icsa-20-016-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2019-344-01 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-20-016-01 | Third Party Advisory, US Government Resource |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FDEB227-D50B-402C-9C11-E29F52BC10BB", "versionEndExcluding": "2.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*", "matchCriteriaId": "E876C738-ABF6-4864-98A6-1E06E96A0DF4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "606AFE88-8C9A-4D18-9209-1193B628669F", "versionEndExcluding": "3.01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*", "matchCriteriaId": "138681A2-0146-492B-8E10-06849FC27C6E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxh5744m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F6FF401-ED15-45EE-9A84-171166BF4414", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxh5744m:-:*:*:*:*:*:*:*", "matchCriteriaId": "8B57B894-5AA4-4412-B425-7338CB2FFA3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxh5724m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "70CD95A2-9FAE-4A7E-8331-8904C0E0CE3D", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxh5724m:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1F56BA4-6A19-44FB-8555-7360C77F83AF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp576634m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5EEE1F8-0DCA-4D18-A022-5DBE980F3A16", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp576634m_:-:*:*:*:*:*:*:*", "matchCriteriaId": "7F683564-419D-418B-A4D5-BB203F709DD7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp57554m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ED646076-2294-4253-92BF-B95D5D5E87A4", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp57554m:-:*:*:*:*:*:*:*", "matchCriteriaId": "5572E616-5D86-46FF-AEA7-4A12E66F0ED4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp575634m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "98B1574C-2FC7-4A3C-B260-D8372A268F4A", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp575634m:-:*:*:*:*:*:*:*", "matchCriteriaId": "57BF89C2-27F8-4FF5-9E4F-4F0CB6C2F0E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp57454m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "853895C6-5EDF-4767-9653-F5F7826B4A7E", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp57454m:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC537593-1AB7-438E-AB71-EDB469A1DFF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp574634m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC9FBA4C-DA99-4F22-9168-ECD281B090C3", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp574634m:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE60505D-0211-4E8C-B32C-988E25698B1E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp57354m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD7766E8-40EB-4C72-8234-C8D997F98F6C", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp57354m:-:*:*:*:*:*:*:*", "matchCriteriaId": "FAE46047-D9AF-4720-A130-A0F989423F82", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp573634m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9246F10-84D1-4AE0-BF1A-B61EA1E965A2", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp573634m:-:*:*:*:*:*:*:*", "matchCriteriaId": "80500883-2825-46DD-8ED9-4F324A4494CC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp57304m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "889586D3-B64F-42DA-8872-DD44C9790881", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp57304m:-:*:*:*:*:*:*:*", "matchCriteriaId": "B5FDBAB3-C8C2-47F6-ACAA-B89BA53849B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp57254m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6EBCADE-8F8C-402B-8FB6-62237168E788", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp57254m:-:*:*:*:*:*:*:*", "matchCriteriaId": "57B75D71-11CA-4DDF-849A-08A9D84C95AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp572634m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33E3F062-3874-4EB6-829B-285B428E982E", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp572634m:-:*:*:*:*:*:*:*", "matchCriteriaId": "EA2094F4-976F-44FA-A7E5-93E20A80DA00", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp57204m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "43BE3D1E-5F7D-409F-A932-073D5A566180", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp57204m_:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E25651C-E4B5-47A2-A6CE-79F7ECAE246E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp571634m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1DEF9B5-6BC0-43A7-AD74-81F9D23BA843", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp571634m:-:*:*:*:*:*:*:*", "matchCriteriaId": "31A5DCC8-9E3D-4919-9DE3-73FC8733E73D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp57154m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E358F77-1F8F-4F2F-A54C-B5F2373EFEE6", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp57154m:-:*:*:*:*:*:*:*", "matchCriteriaId": "5CC8F0AB-C4A8-40B3-88E0-92F52EA05692", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:tsxp57104m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "56724F0C-2DA8-4710-9D82-EE51FA9B062C", "versionEndExcluding": "3.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:tsxp57104m:-:*:*:*:*:*:*:*", "matchCriteriaId": "587226C6-6BE2-4A42-B593-34498F647B24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:140cpu65150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "97C6F04E-FEF7-4DA4-A819-7E4C3DA173F9", "versionEndExcluding": "3.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:140cpu65150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC3E5496-C3D0-4DF4-A9AF-F227F889840E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:140cpu65160_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E9552C20-F295-4AB7-A44E-FB1072BAD1B3", "versionEndExcluding": "3.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:140cpu65160:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2C2AF70-F0BB-4D17-901C-1FCBECDC44FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:140cpu65260_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1BB8ACFC-C693-4C5A-B256-51FF0835FD69", "versionEndExcluding": "3.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:140cpu65260:-:*:*:*:*:*:*:*", "matchCriteriaId": "3D7304B0-EE18-454B-B3F0-5EF387285D90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:140cpu67261_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "370F0F62-AA12-496B-8107-EEC24B070621", "versionEndExcluding": "3.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:140cpu67261:-:*:*:*:*:*:*:*", "matchCriteriaId": "164AEEA1-666F-428A-BFCB-5DEEEFE1D771", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:140cpu67060_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "06F31148-8213-4B01-AA48-D9D7C515E38A", "versionEndExcluding": "3.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:140cpu67060:-:*:*:*:*:*:*:*", "matchCriteriaId": "8AF2A7A3-89EF-480D-8E6E-20E11CF60A97", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:140cpu67160_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6E3B57D-062A-431D-B96F-28463DE757DF", "versionEndExcluding": "3.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:140cpu67160:-:*:*:*:*:*:*:*", "matchCriteriaId": "3870E952-7A32-43DA-8C66-DE43C862639B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:140cpu67261_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "370F0F62-AA12-496B-8107-EEC24B070621", "versionEndExcluding": "3.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:140cpu67261:-:*:*:*:*:*:*:*", "matchCriteriaId": "164AEEA1-666F-428A-BFCB-5DEEEFE1D771", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:140cpu67260_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "108BA75E-B7B4-4A51-9DB8-B928154DD51A", "versionEndExcluding": "3.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:140cpu67260:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9E4FCBA-4980-4C8F-A185-5E9C4CF9E8B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:140cpu65860_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4D81FBC-7C66-4367-8A0F-7F96C09A56A4", "versionEndExcluding": "3.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:140cpu65860:-:*:*:*:*:*:*:*", "matchCriteriaId": "9B8230FD-0C0A-467C-9BAD-09257739D462", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:140cpu67861_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4419CB2D-AABC-4F77-9C75-42ABA62CBA6B", "versionEndExcluding": "3.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:140cpu67861:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF97B5A6-960F-42BA-A397-09C819A3200C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:140cpu65160s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D793BE48-1025-4C6C-8E7D-82E013DDDE5D", "versionEndExcluding": "3.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:140cpu65160s:-:*:*:*:*:*:*:*", "matchCriteriaId": "95E48F27-F241-4491-AFF7-8BD562F21A52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:140cpu67160s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "41654852-0E58-46CC-A734-F59FE9B83990", "versionEndExcluding": "3.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:140cpu67160s:-:*:*:*:*:*:*:*", "matchCriteriaId": "71C1C17A-9111-49B8-A2CE-3A2FB87616F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP." }, { "lang": "es", "value": "CWE-754: existe una vulnerabilidad de Comprobaci\u00f3n Inapropiada de Condiciones Inusuales o Excepcionales en Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (v\u00e9ase la notificaci\u00f3n de seguridad para versiones espec\u00edficas) que podr\u00eda causar una Denegaci\u00f3n de Servicio cuando se escriben bloques de memoria f\u00edsica espec\u00edficos usando Modbus TCP." } ], "id": "CVE-2019-6856", "lastModified": "2024-11-21T04:47:17.430", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-01-06T23:15:11.317", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Vendor Advisory" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01" }, { "source": "cybersecurity@se.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-754" } ], "source": "cybersecurity@se.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-754" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
ghsa-xhgj-59fx-f85c
Vulnerability from github
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.
{ "affected": [], "aliases": [ "CVE-2019-6856" ], "database_specific": { "cwe_ids": [ "CWE-754" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2020-01-06T23:15:00Z", "severity": "MODERATE" }, "details": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.", "id": "GHSA-xhgj-59fx-f85c", "modified": "2022-05-24T17:05:44Z", "published": "2022-05-24T17:05:44Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2019-6856" }, { "type": "WEB", "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-01" }, { "type": "WEB", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-016-01" } ], "schema_version": "1.4.0", "severity": [] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.