cve-2019-6811
Vulnerability from cvelistv5
Published
2019-09-17 19:55
Modified
2024-08-04 20:31
Severity ?
EPSS score ?
Summary
An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module receives an IP fragmented packet with a length greater than 65535 bytes. The module then requires a power cycle to recover.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric SE | Modicon Quantum 140 NOE771x1 |
Version: version 6.9 and earlier |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:31:04.258Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-253-02/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Modicon Quantum 140 NOE771x1", "vendor": "Schneider Electric SE", "versions": [ { "status": "affected", "version": "version 6.9 and earlier" } ] } ], "descriptions": [ { "lang": "en", "value": "An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module receives an IP fragmented packet with a length greater than 65535 bytes. The module then requires a power cycle to recover." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-754", "description": "Improper Check for Unusual or Exceptional Conditions (CWE-754) ", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-09-17T19:55:08", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-253-02/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2019-6811", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Modicon Quantum 140 NOE771x1", "version": { "version_data": [ { "version_value": "version 6.9 and earlier" } ] } } ] }, "vendor_name": "Schneider Electric SE" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module receives an IP fragmented packet with a length greater than 65535 bytes. The module then requires a power cycle to recover." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Improper Check for Unusual or Exceptional Conditions (CWE-754) " } ] } ] }, "references": { "reference_data": [ { "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-253-02/", "refsource": "CONFIRM", "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-253-02/" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2019-6811", "datePublished": "2019-09-17T19:55:08", "dateReserved": "2019-01-25T00:00:00", "dateUpdated": "2024-08-04T20:31:04.258Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-6811\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2019-09-17T20:15:11.920\",\"lastModified\":\"2024-11-21T04:47:12.350\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module receives an IP fragmented packet with a length greater than 65535 bytes. The module then requires a power cycle to recover.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de Comprobaci\u00f3n Inapropiada de Condiciones Inusuales o Excepcionales (CWE-754) en Modicon Quantum 140 NOE771x1 versi\u00f3n 6.9 y anteriores, lo que podr\u00eda causar una denegaci\u00f3n de servicio cuando el m\u00f3dulo recibe un paquete fragmentado IP con una longitud superior a 65535 bytes. El m\u00f3dulo luego requiere un ciclo de energ\u00eda para recuperarse.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_quantum_140noe77101_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"6.9\",\"matchCriteriaId\":\"4CE0668F-5E8D-4CE2-9C2D-9A2BAD408567\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_quantum_140noe77101:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"820638DC-323D-4187-8468-2495C1505860\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_quantum_140noe77111_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"6.9\",\"matchCriteriaId\":\"6E8B5312-10B0-4B98-93C8-F4259E339129\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_quantum_140noe77111:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4C5587FE-4270-490C-BFE7-6DFC2B7AFE79\"}]}]}],\"references\":[{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2019-253-02/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2019-253-02/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.