cve-2019-5016
Vulnerability from cvelistv5
Published
2019-06-17 20:29
Modified
2024-08-04 19:40
Severity ?
EPSS score ?
Summary
An exploitable arbitrary memory read vulnerability exists in the KCodes NetUSB.ko kernel module which enables the ReadySHARE Printer functionality of at least two NETGEAR Nighthawk Routers and potentially several other vendors/products. A specially crafted index value can cause an invalid memory read, resulting in a denial of service or remote information disclosure. An unauthenticated attacker can send a crafted packet on the local network to trigger this vulnerability.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T19:40:48.991Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "108820", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/108820" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0775" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "KCodes", "vendor": "Talos", "versions": [ { "status": "affected", "version": "NETGEAR Nighthawk AC3200 (R8000) Firmware Version V1.0.4.2810.1.54 (11/7/18) - NetUSB.ko 1.0.2.66" }, { "status": "affected", "version": "NETGEAR Nighthawk AC3000 (R7900) Firmware Version V1.0.3.810.0.37 (11/1/18) - NetUSB.ko 1.0.2.69" } ] } ], "datePublic": "2019-06-14T00:00:00", "descriptions": [ { "lang": "en", "value": "An exploitable arbitrary memory read vulnerability exists in the KCodes NetUSB.ko kernel module which enables the ReadySHARE Printer functionality of at least two NETGEAR Nighthawk Routers and potentially several other vendors/products. A specially crafted index value can cause an invalid memory read, resulting in a denial of service or remote information disclosure. An unauthenticated attacker can send a crafted packet on the local network to trigger this vulnerability." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Information Exposure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-19T17:32:49", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "name": "108820", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/108820" }, { "tags": [ "x_refsource_MISC" ], "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0775" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "ID": "CVE-2019-5016", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "KCodes", "version": { "version_data": [ { "version_value": "NETGEAR Nighthawk AC3200 (R8000) Firmware Version V1.0.4.2810.1.54 (11/7/18) - NetUSB.ko 1.0.2.66" }, { "version_value": "NETGEAR Nighthawk AC3000 (R7900) Firmware Version V1.0.3.810.0.37 (11/1/18) - NetUSB.ko 1.0.2.69" } ] } } ] }, "vendor_name": "Talos" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An exploitable arbitrary memory read vulnerability exists in the KCodes NetUSB.ko kernel module which enables the ReadySHARE Printer functionality of at least two NETGEAR Nighthawk Routers and potentially several other vendors/products. A specially crafted index value can cause an invalid memory read, resulting in a denial of service or remote information disclosure. An unauthenticated attacker can send a crafted packet on the local network to trigger this vulnerability." } ] }, "impact": { "cvss": { "baseScore": 10, "baseSeverity": null, "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200: Information Exposure" } ] } ] }, "references": { "reference_data": [ { "name": "108820", "refsource": "BID", "url": "http://www.securityfocus.com/bid/108820" }, { "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0775", "refsource": "MISC", "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0775" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2019-5016", "datePublished": "2019-06-17T20:29:55", "dateReserved": "2019-01-04T00:00:00", "dateUpdated": "2024-08-04T19:40:48.991Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-5016\",\"sourceIdentifier\":\"talos-cna@cisco.com\",\"published\":\"2019-06-17T21:15:09.830\",\"lastModified\":\"2024-11-21T04:44:11.577\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An exploitable arbitrary memory read vulnerability exists in the KCodes NetUSB.ko kernel module which enables the ReadySHARE Printer functionality of at least two NETGEAR Nighthawk Routers and potentially several other vendors/products. A specially crafted index value can cause an invalid memory read, resulting in a denial of service or remote information disclosure. An unauthenticated attacker can send a crafted packet on the local network to trigger this vulnerability.\"},{\"lang\":\"es\",\"value\":\"Se presenta una vulnerabilidad explotable de lectura de memoria arbitraria en el m\u00f3dulo de kernel NetUSB.ko de KCodes, que habilita la funcionalidad de impresora ReadySHARE de al menos dos routers Nighthawk de NETGEAR y posiblemente otros proveedores y productos. Un valor de \u00edndice especialmente creado puede causar una lectura de memoria no v\u00e1lida, resultando en una denegaci\u00f3n de servicio o divulgaci\u00f3n de informaci\u00f3n remota. Un atacante no autenticado puede enviar un paquete creado en la red local para activar esta vulnerabilidad.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}],\"cvssMetricV30\":[{\"source\":\"talos-cna@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:H\",\"baseScore\":10.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.8}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:P\",\"baseScore\":6.4,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"talos-cna@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:r8000_firmware:1.0.4.28_10.1.54:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9A7373DA-C04F-44AC-851A-07129926C721\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5B39F095-8FE8-43FD-A866-7B613B495984\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:r7900_firmware:1.0.3.810.037:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"418AE296-DA46-4355-A177-ED13386E13CA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C484840F-AF30-4B5C-821A-4DB9BE407BDB\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:kcodes:netusb.ko:1.0.2.66:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E50C7000-235E-461C-A0FF-3329F317A3A8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:kcodes:netusb.ko:1.0.2.69:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"24711D44-41E1-47FE-A806-D9F2ABF2A720\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/108820\",\"source\":\"talos-cna@cisco.com\",\"tags\":[\"Broken Link\"]},{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0775\",\"source\":\"talos-cna@cisco.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/108820\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\"]},{\"url\":\"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0775\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.