cve-2019-17373
Vulnerability from cvelistv5
Published
2019-10-09 12:07
Modified
2024-08-05 01:40
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices allow unauthenticated access to critical .cgi and .htm pages via a substring ending with .jpg, such as by appending ?x=1.jpg to a URL. This affects MBR1515, MBR1516, DGN2200, DGN2200M, DGND3700, WNR2000v2, WNDR3300, WNDR3400, WNR3500, and WNR834Bv2.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T01:40:15.309Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_web_interface_exists_authentication_bypass.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices allow unauthenticated access to critical .cgi and .htm pages via a substring ending with .jpg, such as by appending ?x=1.jpg to a URL. This affects MBR1515, MBR1516, DGN2200, DGN2200M, DGND3700, WNR2000v2, WNDR3300, WNDR3400, WNR3500, and WNR834Bv2." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-10-09T12:07:13", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_web_interface_exists_authentication_bypass.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-17373", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices allow unauthenticated access to critical .cgi and .htm pages via a substring ending with .jpg, such as by appending ?x=1.jpg to a URL. This affects MBR1515, MBR1516, DGN2200, DGN2200M, DGND3700, WNR2000v2, WNDR3300, WNDR3400, WNR3500, and WNR834Bv2." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_web_interface_exists_authentication_bypass.md", "refsource": "MISC", "url": "https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_web_interface_exists_authentication_bypass.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-17373", "datePublished": "2019-10-09T12:07:13", "dateReserved": "2019-10-09T00:00:00", "dateUpdated": "2024-08-05T01:40:15.309Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-17373\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2019-10-09T13:15:20.193\",\"lastModified\":\"2024-11-21T04:32:12.537\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Certain NETGEAR devices allow unauthenticated access to critical .cgi and .htm pages via a substring ending with .jpg, such as by appending ?x=1.jpg to a URL. This affects MBR1515, MBR1516, DGN2200, DGN2200M, DGND3700, WNR2000v2, WNDR3300, WNDR3400, WNR3500, and WNR834Bv2.\"},{\"lang\":\"es\",\"value\":\"Determinados dispositivos NETGEAR permiten el acceso no autenticado a p\u00e1ginas cr\u00edticas .cgi y .htm por medio de una subcadena que termina con .jpg, tal y como al agregar ?x=1.jpg en una URL. Esto afecta a MBR1515, MBR1516, DGN2200, DGN2200M, DGND3700, WNR2000v2, WNDR3300, WNDR3400, WNR3500 y WNR834Bv2.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:mbr1515_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EB638052-409C-4DDF-8DF9-68938F1968F7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:mbr1515:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"03129881-D4E6-4509-8749-30AA2A0FF964\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:mbr1516_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A47C9274-DBBB-438D-B2CB-A64656C14B44\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:mbr1516:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3A28B362-80CD-47DF-BE61-77FE318756AC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:dgn2200_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F7FE771C-4199-4225-B1CE-7BC10CD49F49\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:dgn2200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"37C89394-ED7D-4C5F-9573-47A0378E22C8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:dgn2200m_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A13538C2-75B3-44B3-AFB1-FE8A78464341\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:dgn2200m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F47DC113-247A-4EF1-BA26-0DE0F130E15D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:dgnd3700_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5EB7B918-BE0F-4D06-8DEC-808440959DD7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:dgnd3700:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AEC17F51-BDB8-4B30-B5E9-557CBDFDE785\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wnr2000v2_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"684E46F4-5C25-4A73-A045-461BEF5875A1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wnr2000v2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"31247E55-E754-46D0-9A46-B0D319C21221\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wndr3300_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F1DD8079-4C49-4C70-84DA-F1BB77E31C00\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wndr3300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D5EFA6F2-B466-41DD-AAD6-10CE70DC6CC4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wndr3400_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EAE2C525-B967-4266-8A04-C248075C74E7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wndr3400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"223685E0-7DF2-45A6-A9A7-11FA5BFEA3DB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wnr3500_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"90AA886C-2ECA-43C5-93D5-C092747047E4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wnr3500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C33815C7-7CD6-4E07-9180-1EBA55F0D4B7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wnr834bv2_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"444537A0-6EBE-40E4-9223-6075FDD7289B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wnr834bv2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0B83E1B8-F543-4678-8168-3D9E465BEB7D\"}]}]}],\"references\":[{\"url\":\"https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_web_interface_exists_authentication_bypass.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://github.com/zer0yu/CVE_Request/blob/master/netgear/Netgear_web_interface_exists_authentication_bypass.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.