CVE-2017-11400 (GCVE-0-2017-11400)
Vulnerability from cvelistv5 – Published: 2017-11-20 15:00 – Updated: 2024-08-05 18:05
VLAI
EPSS
VEX
Summary
An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. An incomplete firmware signature allows a local attacker to upgrade the equipment (kernel, file system) with unsigned, attacker-controlled, data. This occurs because the appliance_config file is signed but the .tar.sec file is unsigned.
Severity
6.8 (Medium)
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.belden.com/hubfs/support/security/bul… | x_refsource_MISC |
| https://github.com/airbus-seclab/security-advisor… | x_refsource_MISC |
Date Public
2017-11-20 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T18:05:30.557Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.belden.com/hubfs/support/security/bulletins/Belden-Security-Bulletin-BSECV-2017-14-1v1-1.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/airbus-seclab/security-advisories/blob/master/belden/tofino.txt"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-11-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. An incomplete firmware signature allows a local attacker to upgrade the equipment (kernel, file system) with unsigned, attacker-controlled, data. This occurs because the appliance_config file is signed but the .tar.sec file is unsigned."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-11-20T14:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.belden.com/hubfs/support/security/bulletins/Belden-Security-Bulletin-BSECV-2017-14-1v1-1.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/airbus-seclab/security-advisories/blob/master/belden/tofino.txt"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-11400",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. An incomplete firmware signature allows a local attacker to upgrade the equipment (kernel, file system) with unsigned, attacker-controlled, data. This occurs because the appliance_config file is signed but the .tar.sec file is unsigned."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.belden.com/hubfs/support/security/bulletins/Belden-Security-Bulletin-BSECV-2017-14-1v1-1.pdf",
"refsource": "MISC",
"url": "https://www.belden.com/hubfs/support/security/bulletins/Belden-Security-Bulletin-BSECV-2017-14-1v1-1.pdf"
},
{
"name": "https://github.com/airbus-seclab/security-advisories/blob/master/belden/tofino.txt",
"refsource": "MISC",
"url": "https://github.com/airbus-seclab/security-advisories/blob/master/belden/tofino.txt"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-11400",
"datePublished": "2017-11-20T15:00:00.000Z",
"dateReserved": "2017-07-17T00:00:00.000Z",
"dateUpdated": "2024-08-05T18:05:30.557Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2017-11400",
"date": "2026-07-15",
"epss": "0.00273",
"percentile": "0.1916"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:belden:tofino_xenon_security_appliance_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"3.1.0\", \"matchCriteriaId\": \"9FD9B53A-9BC6-4851-B75F-C491B1802A81\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:belden:tofino_xenon_security_appliance:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1957DB06-C01D-4325-81B7-45FA93040101\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. An incomplete firmware signature allows a local attacker to upgrade the equipment (kernel, file system) with unsigned, attacker-controlled, data. This occurs because the appliance_config file is signed but the .tar.sec file is unsigned.\"}, {\"lang\": \"es\", \"value\": \"Se ha descubierto un problema en las versiones anteriores a la 03.2.00 de Belden Hirschmann Tofino Xenon Security Appliance. Una firma incompleta del firmware permite que un atacante local actualice el equipamiento (kernel, sistema de archivo) con datos no firmados controlados por el atacante. Esto ocurre debido a que el archivo appliance_config est\\u00e1 firmado, pero el archivo .tar.sec no lo est\\u00e1.\"}]",
"id": "CVE-2017-11400",
"lastModified": "2024-11-21T03:07:42.613",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 6.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"PHYSICAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 7.2, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 3.9, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2017-11-20T15:29:00.230",
"references": "[{\"url\": \"https://github.com/airbus-seclab/security-advisories/blob/master/belden/tofino.txt\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.belden.com/hubfs/support/security/bulletins/Belden-Security-Bulletin-BSECV-2017-14-1v1-1.pdf\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://github.com/airbus-seclab/security-advisories/blob/master/belden/tofino.txt\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.belden.com/hubfs/support/security/bulletins/Belden-Security-Bulletin-BSECV-2017-14-1v1-1.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-347\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2017-11400\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2017-11-20T15:29:00.230\",\"lastModified\":\"2026-05-13T00:24:29.033\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. An incomplete firmware signature allows a local attacker to upgrade the equipment (kernel, file system) with unsigned, attacker-controlled, data. This occurs because the appliance_config file is signed but the .tar.sec file is unsigned.\"},{\"lang\":\"es\",\"value\":\"Se ha descubierto un problema en las versiones anteriores a la 03.2.00 de Belden Hirschmann Tofino Xenon Security Appliance. Una firma incompleta del firmware permite que un atacante local actualice el equipamiento (kernel, sistema de archivo) con datos no firmados controlados por el atacante. Esto ocurre debido a que el archivo appliance_config est\u00e1 firmado, pero el archivo .tar.sec no lo est\u00e1.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-347\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:belden:tofino_xenon_security_appliance_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.1.0\",\"matchCriteriaId\":\"9FD9B53A-9BC6-4851-B75F-C491B1802A81\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:belden:tofino_xenon_security_appliance:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1957DB06-C01D-4325-81B7-45FA93040101\"}]}]}],\"references\":[{\"url\":\"https://github.com/airbus-seclab/security-advisories/blob/master/belden/tofino.txt\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.belden.com/hubfs/support/security/bulletins/Belden-Security-Bulletin-BSECV-2017-14-1v1-1.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://github.com/airbus-seclab/security-advisories/blob/master/belden/tofino.txt\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.belden.com/hubfs/support/security/bulletins/Belden-Security-Bulletin-BSECV-2017-14-1v1-1.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…