CVE-2014-2304 (GCVE-0-2014-2304)

Vulnerability from cvelistv5 – Published: 2019-10-23 17:01 – Updated: 2024-08-06 10:06
VLAI
Summary
A vulnerability in version 0.90 of the Open Floodlight SDN controller software could result in a denial of service attack and crashing of the controller service. This effect is the result of a flaw in OpenFlow protocol processing, where specific malformed and mistimed FEATURES_REPLY messages cause the controller service to not delete switch and port data from its internal tracking structures.
CWE
  • n/a
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T10:06:00.338Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in version 0.90 of the Open Floodlight SDN controller software could result in a denial of service attack and crashing of the controller service. This effect is the result of a flaw in OpenFlow protocol processing, where specific malformed and mistimed FEATURES_REPLY messages cause the controller service to not delete switch and port data from its internal tracking structures."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T17:01:41.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-2304",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in version 0.90 of the Open Floodlight SDN controller software could result in a denial of service attack and crashing of the controller service. This effect is the result of a flaw in OpenFlow protocol processing, where specific malformed and mistimed FEATURES_REPLY messages cause the controller service to not delete switch and port data from its internal tracking structures."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf",
              "refsource": "MISC",
              "url": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-2304",
    "datePublished": "2019-10-23T17:01:41.000Z",
    "dateReserved": "2014-03-06T00:00:00.000Z",
    "dateUpdated": "2024-08-06T10:06:00.338Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2014-2304",
      "date": "2026-09-30",
      "epss": "0.01099",
      "percentile": "0.64363"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:projectfloodlight:open_sdn_controller:0.90:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D272E939-9490-4C5B-87CB-8AE4FE9D122B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in version 0.90 of the Open Floodlight SDN controller software could result in a denial of service attack and crashing of the controller service. This effect is the result of a flaw in OpenFlow protocol processing, where specific malformed and mistimed FEATURES_REPLY messages cause the controller service to not delete switch and port data from its internal tracking structures."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad en la versi\u00f3n 0.90 del software del controlador SDN de Open Floodlight, podr\u00eda resultar en un ataque de denegaci\u00f3n de servicio y el bloqueo del servicio del controlador. Este efecto es el resultado de un fallo en el procesamiento del protocolo OpenFlow, donde los mensajes de FEATURES_REPLY malformados y sincronizados inapropiadamente espec\u00edficos hacen que el servicio del controlador no elimine los datos del switch y del puerto de sus estructuras de seguimiento internas."
        }
      ],
      "id": "CVE-2014-2304",
      "lastModified": "2024-11-21T02:06:02.460",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-10-23T18:15:11.163",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:projectfloodlight:open_sdn_controller:0.90:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D272E939-9490-4C5B-87CB-8AE4FE9D122B",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability in version 0.90 of the Open Floodlight SDN controller software could result in a denial of service attack and crashing of the controller service. This effect is the result of a flaw in OpenFlow protocol processing, where specific malformed and mistimed FEATURES_REPLY messages cause the controller service to not delete switch and port data from its internal tracking structures."
          },
          {
            "lang": "es",
            "value": "Una vulnerabilidad en la versi\u00f3n 0.90 del software del controlador SDN de Open Floodlight, podr\u00eda resultar en un ataque de denegaci\u00f3n de servicio y el bloqueo del servicio del controlador. Este efecto es el resultado de un fallo en el procesamiento del protocolo OpenFlow, donde los mensajes de FEATURES_REPLY malformados y sincronizados inapropiadamente espec\u00edficos hacen que el servicio del controlador no elimine los datos del switch y del puerto de sus estructuras de seguimiento internas."
          }
        ],
        "id": "CVE-2014-2304",
        "lastModified": "2024-11-21T02:06:02.460",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2019-10-23T18:15:11.163",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "http://dovernetworks.com/wp-content/uploads/2014/03/OpenFloodlight-03052014.pdf"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-20"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…