Summary
The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T15:52:21.430Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15805" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-01" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15805/en_US/GEIP13-04%20Security%20Advisory%20-%20Proficy%20HMI%20SCADA%20DNP3%20Driver%20from%20Catapult%20Software.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2013-10-07T00:00:00", "descriptions": [ { "lang": "en", "value": "The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2013-11-23T18:10:04", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15805" }, { "tags": [ "x_refsource_MISC" ], "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-01" }, { "tags": [ "x_refsource_MISC" ], "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15805/en_US/GEIP13-04%20Security%20Advisory%20-%20Proficy%20HMI%20SCADA%20DNP3%20Driver%20from%20Catapult%20Software.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2013-2811", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15805", "refsource": "CONFIRM", "url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15805" }, { "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-01", "refsource": "MISC", "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-01" }, { "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-02", "refsource": "MISC", "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-297-02" }, { "name": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15805/en_US/GEIP13-04%20Security%20Advisory%20-%20Proficy%20HMI%20SCADA%20DNP3%20Driver%20from%20Catapult%20Software.pdf", "refsource": "CONFIRM", "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15805/en_US/GEIP13-04%20Security%20Advisory%20-%20Proficy%20HMI%20SCADA%20DNP3%20Driver%20from%20Catapult%20Software.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2013-2811", "datePublished": "2013-11-22T01:00:00", "dateReserved": "2013-04-11T00:00:00", "dateUpdated": "2024-08-06T15:52:21.430Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2013-2811\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2013-11-22T01:55:03.763\",\"lastModified\":\"2024-11-21T01:52:24.630\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet.\"},{\"lang\":\"es\",\"value\":\"El driver (1) Catapult DNP3 I/O anterior a la versi\u00f3n 7.2.0.60 y (2) el driver GE Intelligent Platforms Proficy DNP3 I/O anterior a 7.20k, tal y como se usa en DNPDrv.exe (tambi\u00e9n conocido como servidor de estaci\u00f3n maestro DNP) en GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY e iFIX, permite a atacantes remotos provocar una denegaci\u00f3n de servicio (bucle infinito) a trav\u00e9s de paquetes DNP3 TCP manipulados.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:N/A:C\",\"baseScore\":7.1,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:catapultsoftware:catapult_dnp3_i\\\\/o_driver:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.20.56\",\"matchCriteriaId\":\"0D4D11DB-CF90-4ADD-AB95-9815FC90F97B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\\\/o_driver:*:j:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.20\",\"matchCriteriaId\":\"9FBAD16C-05F0-4D83-8FE7-F3FD0E2B75C7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\\\/o_driver:7.20:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"92C2AB50-34CB-4296-8CCE-B98026DB4F0E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\\\/o_driver:7.20:a:*:*:*:*:*:*\",\"matchCriteriaId\":\"4BE9590D-9264-4942-A18C-8629420FBB24\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\\\/o_driver:7.20:b:*:*:*:*:*:*\",\"matchCriteriaId\":\"A013ED7F-92C1-42C4-A6AB-4A419BA11611\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\\\/o_driver:7.20:c:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA7AE477-C0A4-497E-8F7B-9D656DC41B2F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\\\/o_driver:7.20:d:*:*:*:*:*:*\",\"matchCriteriaId\":\"C8AECEB6-867F-4796-B56C-C3C8BC53D691\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\\\/o_driver:7.20:e:*:*:*:*:*:*\",\"matchCriteriaId\":\"9ABC3786-A578-4BF3-AF3D-A470BD7565CB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\\\/o_driver:7.20:f:*:*:*:*:*:*\",\"matchCriteriaId\":\"142CA198-EF41-4FFD-BB40-F9B41C4841F2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\\\/o_driver:7.20:g:*:*:*:*:*:*\",\"matchCriteriaId\":\"F058E97B-0B63-4059-968D-9D282570283B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\\\/o_driver:7.20:h:*:*:*:*:*:*\",\"matchCriteriaId\":\"ED4490C3-8CE5-4715-8E19-1793ED16354D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_dnp3_i\\\\/o_driver:7.20:i:*:*:*:*:*:*\",\"matchCriteriaId\":\"91B378AA-1AFA-44D7-8403-C898C3DAE85D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\\\/scada_cimplicity:4.01:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6C0B8CA7-2161-4603-B844-DE6C079DF36F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\\\/scada_cimplicity:7.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E3BACB11-5CD3-4CA6-9C56-D71628CADF0F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\\\/scada_cimplicity:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"90538C50-38BD-4EE5-BD30-96E2E2951FE3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\\\/scada_cimplicity:8.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CB261867-B9B1-4D3D-B2DE-3CC3164EFD06\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\\\/scada_cimplicity:8.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"559DCD7A-0745-4D4C-A77A-83240EF6C510\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\\\/scada_ifix:5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"65A4CBC3-3B98-4700-8710-4D4FFCA55315\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\\\/scada_ifix:5.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5ABA340B-B00B-41EC-8270-68139B63D09A\"}]}]}],\"references\":[{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-13-297-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-13-297-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15805\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15805/en_US/GEIP13-04%20Security%20Advisory%20-%20Proficy%20HMI%20SCADA%20DNP3%20Driver%20from%20Catapult%20Software.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-13-297-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-13-297-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15805\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15805/en_US/GEIP13-04%20Security%20Advisory%20-%20Proficy%20HMI%20SCADA%20DNP3%20Driver%20from%20Catapult%20Software.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.