GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2026-76672 (GCVE-0-2026-76672)

Vulnerability from cvelistv5 – Published: 2026-09-15 19:23 – Updated: 2026-09-15 19:23
VLAI
Title
Authenticated Sensitive Information Disclosure in HPE Networking EdgeConnect SD-WAN Orchestrator
Summary
A vulnerability exists in the SD-WAN Orchestrator that may lead to the exposure of sensitive configuration information. An authenticated remote attacker with read-only privileges could exploit this vulnerability by sending a specially crafted request to the cache synchronization endpoint. Successful exploitation could result in the disclosure of sensitive third-party API tokens and credentials, potentially enabling lateral movement to external security platforms.
Assigner
Impacted products
Vendor Product Version CPE status
Hewlett Packard Enterprise (HPE) EdgeConnect SD-WAN Gateways Affected: 9.7.0 , ≤ 9.7.0 (semver)
Affected: 9.6.0 , ≤ 9.6.3 (semver)
Affected: 9.5.0 , ≤ 9.5.8 (semver)
Affected: 9.4.0 , ≤ 9.4.10 (semver)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "EdgeConnect SD-WAN Gateways",
          "vendor": "Hewlett Packard Enterprise (HPE)",
          "versions": [
            {
              "lessThanOrEqual": "9.7.0",
              "status": "affected",
              "version": "9.7.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "9.6.3",
              "status": "affected",
              "version": "9.6.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "9.5.8",
              "status": "affected",
              "version": "9.5.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "9.4.10",
              "status": "affected",
              "version": "9.4.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Internal security research (HPE Networking)."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability exists in the SD-WAN Orchestrator that may lead to the exposure of sensitive configuration information. An authenticated remote attacker with read-only privileges could exploit this vulnerability by sending a specially crafted request to the cache synchronization endpoint. Successful exploitation could result in the disclosure of sensitive third-party API tokens and credentials, potentially enabling lateral movement to external security platforms."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-15T19:23:33.951Z",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05135en_us\u0026docLocale=en_US"
        }
      ],
      "source": {
        "advisory": "HPESBNW05135",
        "discovery": "INTERNAL"
      },
      "title": "Authenticated Sensitive Information Disclosure in HPE Networking EdgeConnect SD-WAN Orchestrator",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2026-76672",
    "datePublished": "2026-09-15T19:23:33.951Z",
    "dateReserved": "2026-08-19T16:11:04.542Z",
    "dateUpdated": "2026-09-15T19:23:33.951Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-76672",
      "date": "2026-09-16",
      "epss": "0.00395",
      "percentile": "0.3326"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2026-76672\",\"sourceIdentifier\":\"security-alert@hpe.com\",\"published\":\"2026-09-15T20:17:48.977\",\"lastModified\":\"2026-09-16T19:20:52.817\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability exists in the SD-WAN Orchestrator that may lead to the exposure of sensitive configuration information. An authenticated remote attacker with read-only privileges could exploit this vulnerability by sending a specially crafted request to the cache synchronization endpoint. Successful exploitation could result in the disclosure of sensitive third-party API tokens and credentials, potentially enabling lateral movement to external security platforms.\"}],\"affected\":[{\"source\":\"security-alert@hpe.com\",\"affectedData\":[{\"vendor\":\"Hewlett Packard Enterprise (HPE)\",\"product\":\"EdgeConnect SD-WAN Gateways\",\"defaultStatus\":\"affected\",\"versions\":[{\"version\":\"9.7.0\",\"lessThanOrEqual\":\"9.7.0\",\"versionType\":\"semver\",\"status\":\"affected\"},{\"version\":\"9.6.0\",\"lessThanOrEqual\":\"9.6.3\",\"versionType\":\"semver\",\"status\":\"affected\"},{\"version\":\"9.5.0\",\"lessThanOrEqual\":\"9.5.8\",\"versionType\":\"semver\",\"status\":\"affected\"},{\"version\":\"9.4.0\",\"lessThanOrEqual\":\"9.4.10\",\"versionType\":\"semver\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security-alert@hpe.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:L\",\"baseScore\":9.9,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.1,\"impactScore\":6.0}]},\"references\":[{\"url\":\"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05135en_us\u0026docLocale=en_US\",\"source\":\"security-alert@hpe.com\"}]}}"
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…