CVE-2025-53696 (GCVE-0-2025-53696)
Vulnerability from cvelistv5 – Published: 2025-07-28 14:43 – Updated: 2025-08-19 14:43
VLAI
EPSS
Summary
iSTAR Ultra performs a firmware verification on boot, however the verification does not inspect certain portions of the firmware. These firmware parts may contain malicious code. Tested up to firmware 6.9.2, later firmwares are also possibly affected.
Severity
CWE
- CWE-494 - Download of Code Without Integrity Check
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Johnson Controls, Inc | iSTAR Ultra |
Affected:
0 , ≤ 6.9.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-53696",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-28T15:25:02.419648Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-28T17:57:40.745Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"platforms": [
"Linux"
],
"product": "iSTAR Ultra",
"vendor": "Johnson Controls, Inc",
"versions": [
{
"lessThanOrEqual": "6.9.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "iSTAR Ultra performs a firmware verification on boot, however the verification does not inspect certain portions of the firmware. These firmware parts may contain malicious code. Tested up to firmware 6.9.2, later firmwares are also possibly affected.\u003cbr\u003e"
}
],
"value": "iSTAR Ultra performs a firmware verification on boot, however the verification does not inspect certain portions of the firmware. These firmware parts may contain malicious code. Tested up to firmware 6.9.2, later firmwares are also possibly affected."
}
],
"impacts": [
{
"capecId": "CAPEC-638",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-638 Altered Component Firmware"
}
]
},
{
"capecId": "CAPEC-452",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-452 Infected Hardware"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-19T14:43:13.549Z",
"orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"shortName": "Dragos"
},
"references": [
{
"url": "https://raw.githubusercontent.com/reidmefirst/vuln-disclosure/refs/heads/main/2025-03.txt"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
"assignerShortName": "Dragos",
"cveId": "CVE-2025-53696",
"datePublished": "2025-07-28T14:43:01.059Z",
"dateReserved": "2025-07-08T14:48:42.604Z",
"dateUpdated": "2025-08-19T14:43:13.549Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-53696",
"date": "2026-05-30",
"epss": "0.00042",
"percentile": "0.13152"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2025-53696\",\"sourceIdentifier\":\"ot-cert@dragos.com\",\"published\":\"2025-07-28T15:15:26.670\",\"lastModified\":\"2025-07-29T14:14:29.590\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"iSTAR Ultra performs a firmware verification on boot, however the verification does not inspect certain portions of the firmware. These firmware parts may contain malicious code. Tested up to firmware 6.9.2, later firmwares are also possibly affected.\"},{\"lang\":\"es\",\"value\":\"iSTAR Ultra realiza una verificaci\u00f3n de firmware al arrancar; sin embargo, esta verificaci\u00f3n no inspecciona ciertas partes del firmware. Estas partes podr\u00edan contener c\u00f3digo malicioso. Se prob\u00f3 hasta la versi\u00f3n 6.9.2; las versiones posteriores tambi\u00e9n podr\u00edan verse afectadas.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"ot-cert@dragos.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":9.3,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"HIGH\",\"subIntegrityImpact\":\"HIGH\",\"subAvailabilityImpact\":\"HIGH\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"ot-cert@dragos.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-494\"}]}],\"references\":[{\"url\":\"https://raw.githubusercontent.com/reidmefirst/vuln-disclosure/refs/heads/main/2025-03.txt\",\"source\":\"ot-cert@dragos.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-53696\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-07-28T15:25:02.419648Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-07-28T15:25:04.049Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-638\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-638 Altered Component Firmware\"}]}, {\"capecId\": \"CAPEC-452\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-452 Infected Hardware\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 9.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"LOCAL\", \"baseSeverity\": \"CRITICAL\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"subIntegrityImpact\": \"HIGH\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"HIGH\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"HIGH\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Johnson Controls, Inc\", \"product\": \"iSTAR Ultra\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"6.9.2\"}], \"platforms\": [\"Linux\"], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://raw.githubusercontent.com/reidmefirst/vuln-disclosure/refs/heads/main/2025-03.txt\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"iSTAR Ultra performs a firmware verification on boot, however the verification does not inspect certain portions of the firmware. These firmware parts may contain malicious code. Tested up to firmware 6.9.2, later firmwares are also possibly affected.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"iSTAR Ultra performs a firmware verification on boot, however the verification does not inspect certain portions of the firmware. These firmware parts may contain malicious code. Tested up to firmware 6.9.2, later firmwares are also possibly affected.\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-494\", \"description\": \"CWE-494 Download of Code Without Integrity Check\"}]}], \"providerMetadata\": {\"orgId\": \"12bdf821-1545-4a87-aac5-61670cc6fcef\", \"shortName\": \"Dragos\", \"dateUpdated\": \"2025-08-19T14:43:13.549Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-53696\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-08-19T14:43:13.549Z\", \"dateReserved\": \"2025-07-08T14:48:42.604Z\", \"assignerOrgId\": \"12bdf821-1545-4a87-aac5-61670cc6fcef\", \"datePublished\": \"2025-07-28T14:43:01.059Z\", \"assignerShortName\": \"Dragos\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
FKIE_CVE-2025-53696
Vulnerability from fkie_nvd - Published: 2025-07-28 15:15 - Updated: 2026-04-15 00:35
Severity
Summary
iSTAR Ultra performs a firmware verification on boot, however the verification does not inspect certain portions of the firmware. These firmware parts may contain malicious code. Tested up to firmware 6.9.2, later firmwares are also possibly affected.
References
Impacted products
| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "iSTAR Ultra performs a firmware verification on boot, however the verification does not inspect certain portions of the firmware. These firmware parts may contain malicious code. Tested up to firmware 6.9.2, later firmwares are also possibly affected."
},
{
"lang": "es",
"value": "iSTAR Ultra realiza una verificaci\u00f3n de firmware al arrancar; sin embargo, esta verificaci\u00f3n no inspecciona ciertas partes del firmware. Estas partes podr\u00edan contener c\u00f3digo malicioso. Se prob\u00f3 hasta la versi\u00f3n 6.9.2; las versiones posteriores tambi\u00e9n podr\u00edan verse afectadas."
}
],
"id": "CVE-2025-53696",
"lastModified": "2026-04-15T00:35:42.020",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "ot-cert@dragos.com",
"type": "Secondary"
}
]
},
"published": "2025-07-28T15:15:26.670",
"references": [
{
"source": "ot-cert@dragos.com",
"url": "https://raw.githubusercontent.com/reidmefirst/vuln-disclosure/refs/heads/main/2025-03.txt"
}
],
"sourceIdentifier": "ot-cert@dragos.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-494"
}
],
"source": "ot-cert@dragos.com",
"type": "Secondary"
}
]
}
GHSA-HRV9-XX4C-JM2G
Vulnerability from github – Published: 2025-07-28 15:31 – Updated: 2025-07-28 15:31
VLAI
Details
iSTAR Ultra performs a firmware verification on boot, however the verification does not inspect certain portions of the firmware. These firmware parts may contain malicious code. Tested up to firmware 6.9.2, later firmwares are also possibly affected.
Severity
{
"affected": [],
"aliases": [
"CVE-2025-53696"
],
"database_specific": {
"cwe_ids": [
"CWE-494"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2025-07-28T15:15:26Z",
"severity": "CRITICAL"
},
"details": "iSTAR Ultra performs a firmware verification on boot, however the verification does not inspect certain portions of the firmware. These firmware parts may contain malicious code. Tested up to firmware 6.9.2, later firmwares are also possibly affected.",
"id": "GHSA-hrv9-xx4c-jm2g",
"modified": "2025-07-28T15:31:41Z",
"published": "2025-07-28T15:31:41Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-53696"
},
{
"type": "WEB",
"url": "https://raw.githubusercontent.com/reidmefirst/vuln-disclosure/refs/heads/main/2025-03.txt"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
ICSA-25-219-02
Vulnerability from csaf_cisa - Published: 2025-08-07 06:00 - Updated: 2025-12-04 07:00Summary
Johnson Controls FX Server, FX80 and FX90 (Update A)
Notes
Legal Notice and Terms of Use: This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Risk evaluation: Successful exploitation of this vulnerability could allow an attacker to compromise the device's configuration files.
Critical infrastructure sectors: Critical Manufacturing, Commercial Facilities, Government Services and Facilities, Transportation Systems, Energy
Countries/areas deployed: Worldwide
Company headquarters location: Ireland
Recommended Practices: CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
Recommended Practices: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Recommended Practices: Locate control system networks and remote devices behind firewalls and isolating them from business networks.
Recommended Practices: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Recommended Practices: Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices: No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
7.7 (High)
Affected products
Known affected
6 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Johnson Controls Inc. FX80: <=FX_14.10.10
Johnson Controls Inc. / FX80
|
<=FX_14.10.10 |
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
fix
|
|
|
Johnson Controls Inc. FX80: <=FX_14.14.1
Johnson Controls Inc. / FX80
|
<=FX_14.14.1 |
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
fix
|
|
|
Johnson Controls Inc. FX90: <=FX_14.10.10
Johnson Controls Inc. / FX90
|
<=FX_14.10.10 |
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
fix
|
|
|
Johnson Controls Inc. FX90: <=FX_14.14.1
Johnson Controls Inc. / FX90
|
<=FX_14.14.1 |
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
fix
|
|
|
Johnson Controls Inc. FX Server: <=FX_14.10.10
Johnson Controls Inc. / FX Server
|
<=FX_14.10.10 |
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
fix
|
|
|
Johnson Controls Inc. FX Server: <=FX_14.14.1
Johnson Controls Inc. / FX Server
|
<=FX_14.14.1 |
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
Mitigation
Mitigation
Mitigation
fix
|
References
14 references
Acknowledgments
Johnson Controls
{
"document": {
"acknowledgments": [
{
"organization": "Johnson Controls",
"summary": "reporting this vulnerability to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could allow an attacker to compromise the device\u0027s configuration files.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Critical Manufacturing, Commercial Facilities, Government Services and Facilities, Transportation Systems, Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Ireland",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-25-219-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-219-02.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-25-219-02 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-219-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/secure-our-world/teach-employees-avoid-phishing"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/avoiding-social-engineering-and-phishing-attacks"
}
],
"title": "Johnson Controls FX Server, FX80 and FX90 (Update A)",
"tracking": {
"current_release_date": "2025-12-04T07:00:00.000000Z",
"generator": {
"date": "2025-12-04T13:26:33.753384Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-219-02",
"initial_release_date": "2025-08-07T06:00:00.000000Z",
"revision_history": [
{
"date": "2025-08-07T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
},
{
"date": "2025-12-04T07:00:00.000000Z",
"legacy_version": "Update A",
"number": "2",
"summary": "Update A - Added FX Server to the title and title. Added FX Server affected versions. Added prior versions for all affected products"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=FX_14.10.10",
"product": {
"name": "Johnson Controls Inc. FX80: \u003c=FX_14.10.10",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "FX80"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=FX_14.14.1",
"product": {
"name": "Johnson Controls Inc. FX80: \u003c=FX_14.14.1",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "FX80"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=FX_14.10.10",
"product": {
"name": "Johnson Controls Inc. FX90: \u003c=FX_14.10.10",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "FX90"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=FX_14.14.1",
"product": {
"name": "Johnson Controls Inc. FX90: \u003c=FX_14.14.1",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "FX90"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=FX_14.10.10",
"product": {
"name": "Johnson Controls Inc. FX Server: \u003c=FX_14.10.10",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "FX Server"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=FX_14.14.1",
"product": {
"name": "Johnson Controls Inc. FX Server: \u003c=FX_14.14.1",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "FX Server"
}
],
"category": "vendor",
"name": "Johnson Controls Inc."
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-43867",
"cwe": {
"id": "CWE-1395",
"name": "Dependency on Vulnerable Third-Party Component"
},
"notes": [
{
"category": "summary",
"text": "The affected product is vulnerable to a vulnerable third-party component, which could allow an attacker to compromise device configuration files.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-43867"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H/SC:H/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Johnson Controls recommends users update to the latest version. Successful exploitation of CVE-2025-43867 could trigger CVEs CVE-2025-3936 through CVE-2025-3945.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "For systems running version 14.10.10 or earlier versions, apply the 14.10.11 patch from the software portal.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://www.solutionnavigator.com/sn/SN_ArticleList?category=Software_Downloads\u0026categoryName=Software%20Downloads\u0026GroupName=Facility_Explorer"
},
{
"category": "mitigation",
"details": "For systems running version 14.14.1 or earlier versions, apply the 14.14.2 patch from the software portal.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://www.solutionnavigator.com/sn/SN_ArticleList?category=Software_Downloads\u0026categoryName=Software%20Downloads\u0026GroupName=Facility_Explorer"
},
{
"category": "mitigation",
"details": "Note: FX 14.10.10 contains Niagara 4.10u10",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "Note: FX 14.14.1 contains Niagara 4.14u1",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "Login credentials are required to access the software portal.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "**For more detailed mitigation instructions, visit Johnson Controls Product Security Advisory JCI-PSA-2025-09 v2",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
]
}
]
}
ICSA-25-224-02
Vulnerability from csaf_cisa - Published: 2025-08-12 06:00 - Updated: 2025-12-16 07:00Summary
Johnson Controls iSTAR Ultra, iSTAR Ultra SE, iSTAR Ultra G2, iSTAR Ultra G2 SE, iSTAR Edge G2 (Update A)
Notes
Legal Notice and Terms of Use: This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Risk evaluation: Successful exploitation of these vulnerabilities may allow an attacker to modify firmware and access the space that is protected by the device.
Critical infrastructure sectors: Critical Manufacturing
Countries/areas deployed: Worldwide
Company headquarters location: Ireland
Recommended Practices: CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:
Recommended Practices: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
Recommended Practices: Locate control system networks and remote devices behind firewalls and isolating them from business networks.
Recommended Practices: When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Recommended Practices: Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices: No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
8.8 (High)
Affected products
Known affected
5 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Johnson Controls iSTAR Ultra: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Vendor Fix
Mitigation
fix
Mitigation
fix
Mitigation
Vendor Fix
|
|
|
Johnson Controls iSTAR Ultra SE: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra SE
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
Johnson Controls iSTAR Ultra G2: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra G2
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
Johnson Controls iSTAR Ultra G2 SE: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra G2 SE
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
Johnson Controls iSTAR Edge G2: <=6.9.2.CU02
Johnson Controls / iSTAR Edge G2
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
8.8 (High)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Johnson Controls iSTAR Ultra: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Vendor Fix
Mitigation
fix
Mitigation
fix
Mitigation
Vendor Fix
|
|
|
Johnson Controls iSTAR Ultra SE: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra SE
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
6.7 (Medium)
Affected products
Known affected
5 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Johnson Controls iSTAR Ultra: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Vendor Fix
Mitigation
fix
Mitigation
fix
Mitigation
Vendor Fix
|
|
|
Johnson Controls iSTAR Ultra SE: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra SE
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
Johnson Controls iSTAR Ultra G2: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra G2
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
Johnson Controls iSTAR Ultra G2 SE: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra G2 SE
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
Johnson Controls iSTAR Edge G2: <=6.9.2.CU02
Johnson Controls / iSTAR Edge G2
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
6.8 (Medium)
Affected products
Known affected
2 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Johnson Controls iSTAR Ultra: <6.9.8
Johnson Controls / iSTAR Ultra
|
<6.9.8 |
Mitigation
Vendor Fix
Mitigation
fix
Mitigation
fix
Mitigation
Vendor Fix
|
|
|
Johnson Controls iSTAR Ultra SE: <6.9.8
Johnson Controls / iSTAR Ultra SE
|
<6.9.8 |
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
6.8 (Medium)
Affected products
Known affected
5 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Johnson Controls iSTAR Ultra: <6.9.8
Johnson Controls / iSTAR Ultra
|
<6.9.8 |
Mitigation
Vendor Fix
Mitigation
fix
Mitigation
fix
Mitigation
Vendor Fix
|
|
|
Johnson Controls iSTAR Ultra SE: <6.9.8
Johnson Controls / iSTAR Ultra SE
|
<6.9.8 |
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
Johnson Controls iSTAR Ultra G2: vers:all/*
Johnson Controls / iSTAR Ultra G2
|
vers:all/* |
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
Johnson Controls iSTAR Ultra G2 SE: vers:all/*
Johnson Controls / iSTAR Ultra G2 SE
|
vers:all/* |
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
Johnson Controls iSTAR Edge G2: vers:all/*
Johnson Controls / iSTAR Edge G2
|
vers:all/* |
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
8.8 (High)
Affected products
Known affected
5 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Johnson Controls iSTAR Ultra: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Vendor Fix
Mitigation
fix
Mitigation
fix
Mitigation
Vendor Fix
|
|
|
Johnson Controls iSTAR Ultra SE: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra SE
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
Johnson Controls iSTAR Ultra G2: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra G2
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
Johnson Controls iSTAR Ultra G2 SE: <=6.9.2.CU02
Johnson Controls / iSTAR Ultra G2 SE
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
|
|
Johnson Controls iSTAR Edge G2: <=6.9.2.CU02
Johnson Controls / iSTAR Edge G2
|
<=6.9.2.CU02 |
Mitigation
Mitigation
Mitigation
fix
Mitigation
fix
Mitigation
|
References
25 references
Acknowledgments
Dragos
Reid Wightman
{
"document": {
"acknowledgments": [
{
"names": [
"Reid Wightman"
],
"organization": "Dragos",
"summary": "reporting these vulnerabilities to Johnson Controls"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities may allow an attacker to modify firmware and access the space that is protected by the device.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Ireland",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-25-224-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-224-02.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-25-224-02 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-224-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/secure-our-world/teach-employees-avoid-phishing"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/avoiding-social-engineering-and-phishing-attacks"
}
],
"title": "Johnson Controls iSTAR Ultra, iSTAR Ultra SE, iSTAR Ultra G2, iSTAR Ultra G2 SE, iSTAR Edge G2 (Update A)",
"tracking": {
"current_release_date": "2025-12-16T07:00:00.000000Z",
"generator": {
"date": "2025-12-16T15:51:44.740245Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-224-02",
"initial_release_date": "2025-08-12T06:00:00.000000Z",
"revision_history": [
{
"date": "2025-08-12T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
},
{
"date": "2025-12-16T07:00:00.000000Z",
"legacy_version": "Update A",
"number": "2",
"summary": "Update A - Added version 6.9.8 as a mitigation."
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=6.9.2.CU02",
"product": {
"name": "Johnson Controls iSTAR Ultra: \u003c=6.9.2.CU02",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "iSTAR Ultra"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=6.9.2.CU02",
"product": {
"name": "Johnson Controls iSTAR Ultra SE: \u003c=6.9.2.CU02",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "iSTAR Ultra SE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=6.9.2.CU02",
"product": {
"name": "Johnson Controls iSTAR Ultra G2: \u003c=6.9.2.CU02",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "iSTAR Ultra G2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=6.9.2.CU02",
"product": {
"name": "Johnson Controls iSTAR Ultra G2 SE: \u003c=6.9.2.CU02",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "iSTAR Ultra G2 SE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=6.9.2.CU02",
"product": {
"name": "Johnson Controls iSTAR Edge G2: \u003c=6.9.2.CU02",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "iSTAR Edge G2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c6.9.8",
"product": {
"name": "Johnson Controls iSTAR Ultra: \u003c6.9.8",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "iSTAR Ultra"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c6.9.8",
"product": {
"name": "Johnson Controls iSTAR Ultra SE: \u003c6.9.8",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "iSTAR Ultra SE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Johnson Controls iSTAR Ultra G2: vers:all/*",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "iSTAR Ultra G2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Johnson Controls iSTAR Ultra G2 SE: vers:all/*",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "iSTAR Ultra G2 SE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Johnson Controls iSTAR Edge G2: vers:all/*",
"product_id": "CSAFPID-0010"
}
}
],
"category": "product_name",
"name": "iSTAR Edge G2"
}
],
"category": "vendor",
"name": "Johnson Controls"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-53695",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "OS command injection in iSTAR Ultra, Ultra SE, Ultra G2, Ultra G2 SE, Edge G2 versions 6.9.2 and prior web application allows an authenticated attacker to gain even more privileged access (\u0027root\u0027 user) to the device firmware. This is fixed in versions 6.9.3 and newer.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-53695"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Johnson Controls made firmware version 6.9.3 available in 2024 to fix CVE-2025-53695 and lower the risk of exploitation for CVE-2025-53696, CVE-2025-53697, and CVE-2025-53700.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "Johnson Controls recommends users upgrade iStar Ultra and Ultra SE door controllers to version 6.9.8 to protect for cases where the attacker has physical access to the door controller.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "vendor_fix",
"details": "According to Johnson Controls, the iSTAR Ultra is an older device that has a planned end of service date within a year from this publication. Johnson Controls recommends users consider upgrading to a newer control unit. The hardware installation manual for iSTAR Ultra requires all control units be installed in a restricted access, protected area to lower the risk of physical tampering.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more detailed mitigation instructions, see Johnson Controls Product Security Advisory JCI-PSA-2025-10.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
],
"url": "https://www.johnsoncontrols.com/-/media/project/jci-global/johnson-controls/us-region/united-states-johnson-controls/trust-center/jci-psa-2025-10.pdf"
},
{
"category": "mitigation",
"details": "For assistance and additional information, contact Johnson Controls Trust Center.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
],
"url": "https://www.johnsoncontrols.com/trust-center/cybersecurity"
},
{
"category": "mitigation",
"details": "Dragos recommends end users place the following network restrictions around iSTAR controllers, regardless of model or firmware version:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "vendor_fix",
"details": "Pro Mode on iSTAR Ultra and iSTAR Ultra door controllers should be disabled. Use \"Ultra Mode.\"",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
]
},
{
"cve": "CVE-2025-53696",
"cwe": {
"id": "CWE-349",
"name": "Acceptance of Extraneous Untrusted Data With Trusted Data"
},
"notes": [
{
"category": "summary",
"text": "iSTAR Ultra and Ultra SE versions 6.9.2 and prior performs a firmware verification on boot, however the verification does not inspect certain portions of the firmware. These firmware parts may contain malicious code. Versions 6.9.3 and newer reduce the risk of this vulnerability.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-53696"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Johnson Controls made firmware version 6.9.3 available in 2024 to fix CVE-2025-53695 and lower the risk of exploitation for CVE-2025-53696, CVE-2025-53697, and CVE-2025-53700.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Johnson Controls recommends users upgrade iStar Ultra and Ultra SE door controllers to version 6.9.8 to protect for cases where the attacker has physical access to the door controller.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "According to Johnson Controls, the iSTAR Ultra is an older device that has a planned end of service date within a year from this publication. Johnson Controls recommends users consider upgrading to a newer control unit. The hardware installation manual for iSTAR Ultra requires all control units be installed in a restricted access, protected area to lower the risk of physical tampering.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more detailed mitigation instructions, see Johnson Controls Product Security Advisory JCI-PSA-2025-10.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.johnsoncontrols.com/-/media/project/jci-global/johnson-controls/us-region/united-states-johnson-controls/trust-center/jci-psa-2025-10.pdf"
},
{
"category": "mitigation",
"details": "For assistance and additional information, contact Johnson Controls Trust Center.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.johnsoncontrols.com/trust-center/cybersecurity"
},
{
"category": "mitigation",
"details": "Dragos recommends end users place the following network restrictions around iSTAR controllers, regardless of model or firmware version:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Pro Mode on iSTAR Ultra and iSTAR Ultra door controllers should be disabled. Use \"Ultra Mode.\"",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2025-53697",
"cwe": {
"id": "CWE-1392",
"name": "Use of Default Credentials"
},
"notes": [
{
"category": "summary",
"text": "There is a default \u2018root\u0027 password for iSTAR Ultra, Ultra SE, Ultra G2, Ultra G2 SE, Edge G2 versions 6.9.2 and prior which can be changed through the command shell. iSTAR Ultra and Ultra SE Versions 6.9.3 and newer reduces the risk of this vulnerability. iSTAR Ultra G2, Ultra G2 SE and Edge G2 version 6.9.3 and newer fixes this vulnerability.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-53697"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Johnson Controls made firmware version 6.9.3 available in 2024 to fix CVE-2025-53695 and lower the risk of exploitation for CVE-2025-53696, CVE-2025-53697, and CVE-2025-53700.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "Johnson Controls recommends users upgrade iStar Ultra and Ultra SE door controllers to version 6.9.8 to protect for cases where the attacker has physical access to the door controller.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "vendor_fix",
"details": "According to Johnson Controls, the iSTAR Ultra is an older device that has a planned end of service date within a year from this publication. Johnson Controls recommends users consider upgrading to a newer control unit. The hardware installation manual for iSTAR Ultra requires all control units be installed in a restricted access, protected area to lower the risk of physical tampering.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more detailed mitigation instructions, see Johnson Controls Product Security Advisory JCI-PSA-2025-10.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
],
"url": "https://www.johnsoncontrols.com/-/media/project/jci-global/johnson-controls/us-region/united-states-johnson-controls/trust-center/jci-psa-2025-10.pdf"
},
{
"category": "mitigation",
"details": "For assistance and additional information, contact Johnson Controls Trust Center.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
],
"url": "https://www.johnsoncontrols.com/trust-center/cybersecurity"
},
{
"category": "mitigation",
"details": "Dragos recommends end users place the following network restrictions around iSTAR controllers, regardless of model or firmware version:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "vendor_fix",
"details": "Pro Mode on iSTAR Ultra and iSTAR Ultra door controllers should be disabled. Use \"Ultra Mode.\"",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
]
},
{
"cve": "CVE-2025-53698",
"cwe": {
"id": "CWE-1299",
"name": "Missing Protection Mechanism for Alternate Hardware Interface"
},
"notes": [
{
"category": "summary",
"text": "There is an undocumented RJ11 serial console on the iSTAR GCM (General Controller Module) which provides access to Uboot. On older firmware versions, an attacker with physical access to this console can get direct access to a shell with \u2018root\u0027 privileges. In firmware Version 6.8.1 or newer, the console is disabled once the system has fully booted, however the console may be re-enabled due to lack of protection of the Uboot bootloader. ",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0006",
"CSAFPID-0007"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-53698"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Johnson Controls recommends users upgrade iStar Ultra and Ultra SE door controllers to version 6.9.8 to protect for cases where the attacker has physical access to the door controller.",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0007"
]
},
{
"category": "vendor_fix",
"details": "According to Johnson Controls, the iSTAR Ultra is an older device that has a planned end of service date within a year from this publication. Johnson Controls recommends users consider upgrading to a newer control unit. The hardware installation manual for iSTAR Ultra requires all control units be installed in a restricted access, protected area to lower the risk of physical tampering.",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "For more detailed mitigation instructions, see Johnson Controls Product Security Advisory JCI-PSA-2025-10.",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0007"
],
"url": "https://www.johnsoncontrols.com/-/media/project/jci-global/johnson-controls/us-region/united-states-johnson-controls/trust-center/jci-psa-2025-10.pdf"
},
{
"category": "mitigation",
"details": "For assistance and additional information, contact Johnson Controls Trust Center.",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0007"
],
"url": "https://www.johnsoncontrols.com/trust-center/cybersecurity"
},
{
"category": "mitigation",
"details": "Dragos recommends end users place the following network restrictions around iSTAR controllers, regardless of model or firmware version:",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0007"
]
},
{
"category": "vendor_fix",
"details": "Pro Mode on iSTAR Ultra and iSTAR Ultra door controllers should be disabled. Use \"Ultra Mode.\"",
"product_ids": [
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0006",
"CSAFPID-0007"
]
}
]
},
{
"cve": "CVE-2025-53699",
"cwe": {
"id": "CWE-1299",
"name": "Missing Protection Mechanism for Alternate Hardware Interface"
},
"notes": [
{
"category": "summary",
"text": "USB ports on the GCM board are typically used to connect an ACM (Access Control Module) board. The ACM is what reads badge data, \u2018push to exit\u0027 signals, fire alarm signals, and operates relays to unlock doors. Physical access to GCM USB ports also allows USB devices, such as keyboards, to be connected and the system will treat the input from a connected keyboard as though it were typed on a local console. ",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-53699"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Johnson Controls recommends users upgrade iStar Ultra and Ultra SE door controllers to version 6.9.8 to protect for cases where the attacker has physical access to the door controller.",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010"
]
},
{
"category": "vendor_fix",
"details": "According to Johnson Controls, the iSTAR Ultra is an older device that has a planned end of service date within a year from this publication. Johnson Controls recommends users consider upgrading to a newer control unit. The hardware installation manual for iSTAR Ultra requires all control units be installed in a restricted access, protected area to lower the risk of physical tampering.",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "mitigation",
"details": "For more detailed mitigation instructions, see Johnson Controls Product Security Advisory JCI-PSA-2025-10.",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010"
],
"url": "https://www.johnsoncontrols.com/-/media/project/jci-global/johnson-controls/us-region/united-states-johnson-controls/trust-center/jci-psa-2025-10.pdf"
},
{
"category": "mitigation",
"details": "For assistance and additional information, contact Johnson Controls Trust Center.",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010"
],
"url": "https://www.johnsoncontrols.com/trust-center/cybersecurity"
},
{
"category": "mitigation",
"details": "Dragos recommends end users place the following network restrictions around iSTAR controllers, regardless of model or firmware version:",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010"
]
},
{
"category": "vendor_fix",
"details": "Pro Mode on iSTAR Ultra and iSTAR Ultra door controllers should be disabled. Use \"Ultra Mode.\"",
"product_ids": [
"CSAFPID-0006"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010"
]
}
]
},
{
"cve": "CVE-2025-53700",
"cwe": {
"id": "CWE-922",
"name": "Insecure Storage of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The software signing key for Tyco NVR products is included in the firmware of iSTAR Ultra, Ultra SE, Ultra G2, Ultra G2 SE, Edge G2 versions 6.9.2 and prior. iSTAR Ultra and Ultra SE Versions 6.9.3 and newer reduces the risk of this vulnerability. iSTAR Ultra G2, Ultra G2 SE and Edge G2 version 6.9.3 and newer fixes this vulnerability.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-53700"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Johnson Controls made firmware version 6.9.3 available in 2024 to fix CVE-2025-53695 and lower the risk of exploitation for CVE-2025-53696, CVE-2025-53697, and CVE-2025-53700.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "Johnson Controls recommends users upgrade iStar Ultra and Ultra SE door controllers to version 6.9.8 to protect for cases where the attacker has physical access to the door controller.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "vendor_fix",
"details": "According to Johnson Controls, the iSTAR Ultra is an older device that has a planned end of service date within a year from this publication. Johnson Controls recommends users consider upgrading to a newer control unit. The hardware installation manual for iSTAR Ultra requires all control units be installed in a restricted access, protected area to lower the risk of physical tampering.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more detailed mitigation instructions, see Johnson Controls Product Security Advisory JCI-PSA-2025-10.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
],
"url": "https://www.johnsoncontrols.com/-/media/project/jci-global/johnson-controls/us-region/united-states-johnson-controls/trust-center/jci-psa-2025-10.pdf"
},
{
"category": "mitigation",
"details": "For assistance and additional information, contact Johnson Controls Trust Center.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
],
"url": "https://www.johnsoncontrols.com/trust-center/cybersecurity"
},
{
"category": "mitigation",
"details": "Dragos recommends end users place the following network restrictions around iSTAR controllers, regardless of model or firmware version:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "vendor_fix",
"details": "Pro Mode on iSTAR Ultra and iSTAR Ultra door controllers should be disabled. Use \"Ultra Mode.\"",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
]
}
]
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…