GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2024-37603 (GCVE-0-2024-37603)

Vulnerability from cvelistv5 – Published: 2025-02-13 00:00 – Updated: 2025-02-18 14:08
VLAI
Summary
An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6. A possible type confusion exists in the user data import/export function of NTG 6 head units. To perform this attack, local access to the USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-18 14:08 UTC
CWE
  • n/a
  • CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "HIGH",
              "baseScore": 4.6,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-37603",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-18T14:08:04.038137Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-843",
                "description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-18T14:08:30.182Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6. A possible type confusion exists in the user data import/export function of NTG 6 head units. To perform this attack, local access to the USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-13T22:11:58.317Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://securelist.com/mercedes-benz-head-unit-security-research/115218/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-37603",
    "datePublished": "2025-02-13T00:00:00.000Z",
    "dateReserved": "2024-06-09T00:00:00.000Z",
    "dateUpdated": "2025-02-18T14:08:30.182Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-37603",
      "date": "2026-09-17",
      "epss": "0.00333",
      "percentile": "0.26575"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-37603\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2025-02-13T23:15:10.313\",\"lastModified\":\"2026-06-17T07:38:39.170\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6. A possible type confusion exists in the user data import/export function of NTG 6 head units. To perform this attack, local access to the USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically.\"},{\"lang\":\"es\",\"value\":\"Se ha descubierto un problema en Mercedes Benz NTG (New Telematics Generation) 6. Existe una posible confusi\u00f3n de tipos en la funci\u00f3n de importaci\u00f3n/exportaci\u00f3n de datos de usuario de las unidades principales NTG 6. Para realizar este ataque, se necesita acceso local a la interfaz USB del autom\u00f3vil. Con los datos preparados, un atacante puede provocar que el servicio User-Data falle. La instancia de servicio fallida se reiniciar\u00e1 autom\u00e1ticamente.\"}],\"affected\":[{\"source\":\"cve@mitre.org\",\"affectedData\":[{\"vendor\":\"n/a\",\"product\":\"n/a\",\"versions\":[{\"version\":\"n/a\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":4.6,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":3.6}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2025-02-18T14:08:04.038137Z\",\"id\":\"CVE-2024-37603\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-843\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mercedes-benz:headunit_ntg6_mercedes-benz_user_experience:2021:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"42670EBA-2A3A-4AFD-AFA9-8D16EB0DAAC0\"}]}]}],\"references\":[{\"url\":\"https://securelist.com/mercedes-benz-head-unit-security-research/115218/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]}]}}",
    "redhat_vex": {
      "current_release_date": "2025-05-28T22:20:05+00:00",
      "cve": "CVE-2024-37603",
      "id": "CVE-2024-37603",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2024-37603",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-37603.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 4.6, \"attackVector\": \"PHYSICAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-37603\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-18T14:08:04.038137Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-843\", \"description\": \"CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-14T20:17:00.717Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://securelist.com/mercedes-benz-head-unit-security-research/115218/\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"An issue was discovered in Mercedes Benz NTG (New Telematics Generation) 6. A possible type confusion exists in the user data import/export function of NTG 6 head units. To perform this attack, local access to the USB interface of the car is needed. With prepared data, an attacker can cause the User-Data service to fail. The failed service instance will restart automatically.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2025-02-13T22:11:58.317Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-37603\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-18T14:08:30.182Z\", \"dateReserved\": \"2024-06-09T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2025-02-13T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…