CVE-2024-22439 (GCVE-0-2024-22439)

Vulnerability from cvelistv5 – Published: 2024-04-15 10:08 – Updated: 2024-08-01 22:43
VLAI
Title
Certain HPE FlexNetwork and FlexFabric Switches, Remote Authentication Bypass
Summary
A potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-04-17 20:21 UTC
CWE
  • CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
Impacted products
Vendor Product Version CPE status
Hewlett Packard Enterprise HPE FlexNetwork and FlexFabric products Affected: See security bulletin HPESBNW04625 for details
guessed Create a notification for this product.
Date Public
2024-04-11 09:59
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-22439",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-17T20:21:10.000927Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:52:46.976Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T22:43:34.952Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "platforms": [
            "Custom"
          ],
          "product": "HPE FlexNetwork and FlexFabric products",
          "vendor": "Hewlett Packard Enterprise",
          "versions": [
            {
              "status": "affected",
              "version": "See security bulletin HPESBNW04625 for details"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Zhuo Zixiao and Alwen Tiu of Australian National University (ANU)"
        }
      ],
      "datePublic": "2024-04-11T09:59:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-233",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-233 Privilege Escalation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-639",
              "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-15T10:08:57.234Z",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us"
        }
      ],
      "source": {
        "advisory": "HPESBNW04625",
        "discovery": "UNKNOWN"
      },
      "title": "Certain HPE FlexNetwork and FlexFabric Switches, Remote Authentication Bypass",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2024-22439",
    "datePublished": "2024-04-15T10:08:57.234Z",
    "dateReserved": "2024-01-10T15:24:39.967Z",
    "dateUpdated": "2024-08-01T22:43:34.952Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-22439",
      "date": "2026-09-23",
      "epss": "0.002",
      "percentile": "0.10214"
    },
    "fkie_nvd": {
      "descriptions": [
        {
          "lang": "en",
          "value": "\nA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\n\n"
        },
        {
          "lang": "es",
          "value": "Se ha identificado una posible vulnerabilidad de seguridad en los productos de las series HPE FlexFabric y FlexNetwork. Esta vulnerabilidad podr\u00eda aprovecharse para obtener acceso privilegiado a conmutadores, lo que dar\u00eda como resultado la divulgaci\u00f3n de informaci\u00f3n."
        }
      ],
      "id": "CVE-2024-22439",
      "lastModified": "2024-11-21T08:56:17.590",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.7,
            "impactScore": 4.7,
            "source": "security-alert@hpe.com",
            "type": "Secondary"
          }
        ]
      },
      "published": "2024-04-15T10:15:08.747",
      "references": [
        {
          "source": "security-alert@hpe.com",
          "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us"
        }
      ],
      "sourceIdentifier": "security-alert@hpe.com",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-639"
            }
          ],
          "source": "security-alert@hpe.com",
          "type": "Secondary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "affected",
                "platforms": [
                  "Custom"
                ],
                "product": "HPE FlexNetwork and FlexFabric products",
                "vendor": "Hewlett Packard Enterprise",
                "versions": [
                  {
                    "status": "affected",
                    "version": "See security bulletin HPESBNW04625 for details"
                  }
                ]
              }
            ],
            "source": "security-alert@hpe.com"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "\nA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\n\n"
          },
          {
            "lang": "es",
            "value": "Se ha identificado una posible vulnerabilidad de seguridad en los productos de las series HPE FlexFabric y FlexNetwork. Esta vulnerabilidad podr\u00eda aprovecharse para obtener acceso privilegiado a conmutadores, lo que dar\u00eda como resultado la divulgaci\u00f3n de informaci\u00f3n."
          }
        ],
        "id": "CVE-2024-22439",
        "lastModified": "2026-06-17T07:11:24.733",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:L/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.7,
              "impactScore": 4.7,
              "source": "security-alert@hpe.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-22439",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-17T20:21:10.000927Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-04-15T10:15:08.747",
        "references": [
          {
            "source": "security-alert@hpe.com",
            "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us"
          }
        ],
        "sourceIdentifier": "security-alert@hpe.com",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-639"
              }
            ],
            "source": "security-alert@hpe.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T19:03:18+00:00",
      "cve": "CVE-2024-22439",
      "id": "CVE-2024-22439",
      "initial_release_date": "2024-04-11T09:59:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Certain HPE FlexNetwork and FlexFabric Switches, Remote Authentication Bypass",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-22439.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T22:43:34.952Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-22439",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-17T20:21:10.000927Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-05-23T19:01:23.838Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "platforms": [
                "Custom"
              ],
              "product": "HPE FlexNetwork and FlexFabric products",
              "vendor": "Hewlett Packard Enterprise",
              "versions": [
                {
                  "status": "affected",
                  "version": "See security bulletin HPESBNW04625 for details"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Zhuo Zixiao and Alwen Tiu of Australian National University (ANU)"
            }
          ],
          "datePublic": "2024-04-11T09:59:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nA potential security vulnerability has been identified in HPE FlexFabric and FlexNetwork series products. This vulnerability could be exploited to gain privileged access to switches resulting in information disclosure.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-233",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-233 Privilege Escalation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-639",
                  "description": "CWE-639 Authorization Bypass Through User-Controlled Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-15T10:08:57.234Z",
            "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
            "shortName": "hpe"
          },
          "references": [
            {
              "url": "https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US\u0026docId=hpesbnw04625en_us"
            }
          ],
          "source": {
            "advisory": "HPESBNW04625",
            "discovery": "UNKNOWN"
          },
          "title": "Certain HPE FlexNetwork and FlexFabric Switches, Remote Authentication Bypass",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "assignerShortName": "hpe",
        "cveId": "CVE-2024-22439",
        "datePublished": "2024-04-15T10:08:57.234Z",
        "dateReserved": "2024-01-10T15:24:39.967Z",
        "dateUpdated": "2024-08-01T22:43:34.952Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…