CVE-2023-40704
Vulnerability from cvelistv5
Published
2024-07-18 16:33
Modified
2025-04-09 20:17
Summary
The product does not require unique and complex passwords to be created during installation. Using Philips's default password could jeopardize the PACS system if the password was hacked or leaked. An attacker could gain access to the database impacting system availability and data integrity.
Impacted products
Vendor Product Version
Philips Vue PACS Version: 0   < 12.2.8.410
Create a notification for this product.
Show details on NVD website


{
   containers: {
      adp: [
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:a:philips:vue_pacs:*:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unaffected",
                  product: "vue_pacs",
                  vendor: "philips",
                  versions: [
                     {
                        lessThan: "12.2.8.410",
                        status: "affected",
                        version: "0",
                        versionType: "custom",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2023-40704",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-07-18T17:50:31.631061Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-07-18T17:58:24.997Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
         {
            providerMetadata: {
               dateUpdated: "2024-08-02T18:38:51.075Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-200-01",
               },
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "http://www.philips.com/productsecurity",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unaffected",
               product: "Vue PACS",
               vendor: "Philips",
               versions: [
                  {
                     lessThan: "12.2.8.410",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
         ],
         credits: [
            {
               lang: "en",
               type: "finder",
               value: "TAS Health NZ and Camiel van Es reported these vulnerabilities to Philips.",
            },
         ],
         datePublic: "2024-07-18T15:00:00.000Z",
         descriptions: [
            {
               lang: "en",
               supportingMedia: [
                  {
                     base64: false,
                     type: "text/html",
                     value: "<span style=\"background-color: rgb(255, 255, 255);\">\n\n<span style=\"background-color: rgb(255, 255, 255);\">\nThe product does not require unique and complex passwords to be created \nduring installation. Using Philips's default password could jeopardize \nthe PACS system if the password was hacked or leaked. An attacker could \ngain access to the database impacting system availability and data \nintegrity.\n\n</span>\n\n</span>",
                  },
               ],
               value: "The product does not require unique and complex passwords to be created \nduring installation. Using Philips's default password could jeopardize \nthe PACS system if the password was hacked or leaked. An attacker could \ngain access to the database impacting system availability and data \nintegrity.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  attackComplexity: "LOW",
                  attackVector: "ADJACENT_NETWORK",
                  availabilityImpact: "HIGH",
                  baseScore: 6.8,
                  baseSeverity: "MEDIUM",
                  confidentialityImpact: "HIGH",
                  integrityImpact: "HIGH",
                  privilegesRequired: "HIGH",
                  scope: "UNCHANGED",
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
               format: "CVSS",
               scenarios: [
                  {
                     lang: "en",
                     value: "GENERAL",
                  },
               ],
            },
            {
               cvssV4_0: {
                  Automatable: "NOT_DEFINED",
                  Recovery: "NOT_DEFINED",
                  Safety: "NOT_DEFINED",
                  attackComplexity: "HIGH",
                  attackRequirements: "NONE",
                  attackVector: "LOCAL",
                  baseScore: 5.7,
                  baseSeverity: "MEDIUM",
                  privilegesRequired: "HIGH",
                  providerUrgency: "NOT_DEFINED",
                  subAvailabilityImpact: "NONE",
                  subConfidentialityImpact: "NONE",
                  subIntegrityImpact: "NONE",
                  userInteraction: "NONE",
                  valueDensity: "NOT_DEFINED",
                  vectorString: "CVSS:4.0/AV:L/AC:H/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N",
                  version: "4.0",
                  vulnAvailabilityImpact: "HIGH",
                  vulnConfidentialityImpact: "HIGH",
                  vulnIntegrityImpact: "LOW",
                  vulnerabilityResponseEffort: "NOT_DEFINED",
               },
               format: "CVSS",
               scenarios: [
                  {
                     lang: "en",
                     value: "GENERAL",
                  },
               ],
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-1392",
                     description: "CWE-1392 Use of Default Credentials",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2025-04-09T20:17:10.791Z",
            orgId: "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            shortName: "icscert",
         },
         references: [
            {
               url: "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-200-01",
            },
            {
               url: "http://www.philips.com/productsecurity",
            },
         ],
         solutions: [
            {
               lang: "en",
               supportingMedia: [
                  {
                     base64: false,
                     type: "text/html",
                     value: "<p>Philips recommends the following mitigations:</p>\n<ul>\n<li>For CVE-2021-28165, Philips recommends configuring the Vue PACS \nenvironment per D000763414 – Vue_PACS_12_Ports_Protocols_Services_Guide \navailable on <a target=\"_blank\" rel=\"nofollow\" href=\"https://incenter.medical.philips.com/Default.aspx?tabid=867\">Incenter</a>. Vue PACS version 12.2.8.410* released in October 2023 prevents this vulnerability.</li>\n<li>For CVE-2023-40704, Philips recommends no action needed due to low \nrisk of exploitability, but customers can request that Philips update \ndatabase password(s).</li>\n</ul>\n<p>For managed services users, new releases will be made available upon \nresource availability. Releases are subject to country specific \nregulations. Users with questions regarding their specific Philips Vue \nPACS installations and new release eligibility should contact their \nlocal Philips sales representative or submit a request in the <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.informatics.support.philips.com/csm\">Philips Informatics Support portal</a>.</p>\n<p>Refer to the <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.philips.com/productsecurity\">Philips advisory</a> for more details.\n\n<br></p>",
                  },
               ],
               value: "Philips recommends the following mitigations:\n\n\n\n  *  For CVE-2021-28165, Philips recommends configuring the Vue PACS \nenvironment per D000763414 – Vue_PACS_12_Ports_Protocols_Services_Guide \navailable on  Incenter https://incenter.medical.philips.com/Default.aspx . Vue PACS version 12.2.8.410* released in October 2023 prevents this vulnerability.\n\n  *  For CVE-2023-40704, Philips recommends no action needed due to low \nrisk of exploitability, but customers can request that Philips update \ndatabase password(s).\n\n\n\n\nFor managed services users, new releases will be made available upon \nresource availability. Releases are subject to country specific \nregulations. Users with questions regarding their specific Philips Vue \nPACS installations and new release eligibility should contact their \nlocal Philips sales representative or submit a request in the  Philips Informatics Support portal https://www.informatics.support.philips.com/csm .\n\n\nRefer to the  Philips advisory https://www.philips.com/productsecurity  for more details.",
            },
         ],
         source: {
            advisory: "ICSMA-24-200-01",
            discovery: "EXTERNAL",
         },
         title: "Philips Vue PACS Use of Default Credentials",
         x_generator: {
            engine: "Vulnogram 0.2.0",
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
      assignerShortName: "icscert",
      cveId: "CVE-2023-40704",
      datePublished: "2024-07-18T16:33:27.444Z",
      dateReserved: "2023-08-21T22:12:52.587Z",
      dateUpdated: "2025-04-09T20:17:10.791Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      nvd: "{\"cve\":{\"id\":\"CVE-2023-40704\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2024-07-18T17:15:03.897\",\"lastModified\":\"2025-04-09T21:16:24.990\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The product does not require unique and complex passwords to be created \\nduring installation. Using Philips's default password could jeopardize \\nthe PACS system if the password was hacked or leaked. An attacker could \\ngain access to the database impacting system availability and data \\nintegrity.\"},{\"lang\":\"es\",\"value\":\"Philips Vue PACS utiliza credenciales predeterminadas para funciones potencialmente críticas.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:H/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1392\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:philips:vue_pacs:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.2.8.410\",\"matchCriteriaId\":\"E3D16037-0684-4486-80A7-8EE98DD4E851\"}]}]}],\"references\":[{\"url\":\"http://www.philips.com/productsecurity\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Product\"]},{\"url\":\"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-200-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://www.philips.com/productsecurity\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Product\"]},{\"url\":\"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-200-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}",
      vulnrichment: {
         containers: "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-200-01\", \"tags\": [\"x_transferred\"]}, {\"url\": \"http://www.philips.com/productsecurity\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T18:38:51.075Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-40704\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-18T17:50:31.631061Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:philips:vue_pacs:*:*:*:*:*:*:*:*\"], \"vendor\": \"philips\", \"product\": \"vue_pacs\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"12.2.8.410\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-18T17:52:21.270Z\"}}], \"cna\": {\"title\": \"Philips Vue PACS Use of Default Credentials\", \"source\": {\"advisory\": \"ICSMA-24-200-01\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"TAS Health NZ and Camiel van Es reported these vulnerabilities to Philips.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.8, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 5.7, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:L/AC:H/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"LOW\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Philips\", \"product\": \"Vue PACS\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"12.2.8.410\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Philips recommends the following mitigations:\\n\\n\\n\\n  *  For CVE-2021-28165, Philips recommends configuring the Vue PACS \\nenvironment per D000763414 \\u2013 Vue_PACS_12_Ports_Protocols_Services_Guide \\navailable on  Incenter https://incenter.medical.philips.com/Default.aspx . Vue PACS version 12.2.8.410* released in October 2023 prevents this vulnerability.\\n\\n  *  For CVE-2023-40704, Philips recommends no action needed due to low \\nrisk of exploitability, but customers can request that Philips update \\ndatabase password(s).\\n\\n\\n\\n\\nFor managed services users, new releases will be made available upon \\nresource availability. Releases are subject to country specific \\nregulations. Users with questions regarding their specific Philips Vue \\nPACS installations and new release eligibility should contact their \\nlocal Philips sales representative or submit a request in the  Philips Informatics Support portal https://www.informatics.support.philips.com/csm .\\n\\n\\nRefer to the  Philips advisory https://www.philips.com/productsecurity  for more details.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"<p>Philips recommends the following mitigations:</p>\\n<ul>\\n<li>For CVE-2021-28165, Philips recommends configuring the Vue PACS \\nenvironment per D000763414 \\u2013 Vue_PACS_12_Ports_Protocols_Services_Guide \\navailable on <a target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://incenter.medical.philips.com/Default.aspx?tabid=867\\\">Incenter</a>. Vue PACS version 12.2.8.410* released in October 2023 prevents this vulnerability.</li>\\n<li>For CVE-2023-40704, Philips recommends no action needed due to low \\nrisk of exploitability, but customers can request that Philips update \\ndatabase password(s).</li>\\n</ul>\\n<p>For managed services users, new releases will be made available upon \\nresource availability. Releases are subject to country specific \\nregulations. Users with questions regarding their specific Philips Vue \\nPACS installations and new release eligibility should contact their \\nlocal Philips sales representative or submit a request in the <a target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.informatics.support.philips.com/csm\\\">Philips Informatics Support portal</a>.</p>\\n<p>Refer to the <a target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.philips.com/productsecurity\\\">Philips advisory</a> for more details.\\n\\n<br></p>\", \"base64\": false}]}], \"datePublic\": \"2024-07-18T15:00:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-200-01\"}, {\"url\": \"http://www.philips.com/productsecurity\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The product does not require unique and complex passwords to be created \\nduring installation. Using Philips's default password could jeopardize \\nthe PACS system if the password was hacked or leaked. An attacker could \\ngain access to the database impacting system availability and data \\nintegrity.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"<span style=\\\"background-color: rgb(255, 255, 255);\\\">\\n\\n<span style=\\\"background-color: rgb(255, 255, 255);\\\">\\nThe product does not require unique and complex passwords to be created \\nduring installation. Using Philips's default password could jeopardize \\nthe PACS system if the password was hacked or leaked. An attacker could \\ngain access to the database impacting system availability and data \\nintegrity.\\n\\n</span>\\n\\n</span>\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1392\", \"description\": \"CWE-1392 Use of Default Credentials\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2025-04-09T20:17:10.791Z\"}}}",
         cveMetadata: "{\"cveId\": \"CVE-2023-40704\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-09T20:17:10.791Z\", \"dateReserved\": \"2023-08-21T22:12:52.587Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2024-07-18T16:33:27.444Z\", \"assignerShortName\": \"icscert\"}",
         dataType: "CVE_RECORD",
         dataVersion: "5.1",
      },
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.