CVE-2022-43954
Vulnerability from cvelistv5
Published
2023-02-16 18:05
Modified
2024-10-22 20:50
Summary
An insertion of sensitive information into log file vulnerability [CWE-532] in the FortiPortal management interface 7.0.0 through 7.0.2 may allow a remote authenticated attacker to read other devices' passwords in the audit log page.
Impacted products
Vendor Product Version
Fortinet FortiPortal Version: 7.0.0    7.0.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:04.994Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://fortiguard.com/psirt/FG-IR-22-430",
            "tags": [
              "x_transferred"
            ],
            "url": "https://fortiguard.com/psirt/FG-IR-22-430"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43954",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-22T20:18:43.913620Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-22T20:50:45.705Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FortiPortal",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.0.2",
              "status": "affected",
              "version": "7.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An insertion of sensitive information into log file vulnerability [CWE-532] in the FortiPortal management interface\u00a07.0.0 through 7.0.2 may allow a remote authenticated attacker to read other devices\u0027 passwords in the audit log page."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:F/RL:X/RC:R",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "Information disclosure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-16T18:05:20.138Z",
        "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
        "shortName": "fortinet"
      },
      "references": [
        {
          "name": "https://fortiguard.com/psirt/FG-IR-22-430",
          "url": "https://fortiguard.com/psirt/FG-IR-22-430"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Please upgrade to FortiPortal version 7.0.3 or above "
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
    "assignerShortName": "fortinet",
    "cveId": "CVE-2022-43954",
    "datePublished": "2023-02-16T18:05:20.138Z",
    "dateReserved": "2022-10-27T07:40:06.590Z",
    "dateUpdated": "2024-10-22T20:50:45.705Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-43954\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2023-02-16T19:15:13.650\",\"lastModified\":\"2024-11-21T07:27:24.510\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An insertion of sensitive information into log file vulnerability [CWE-532] in the FortiPortal management interface\u00a07.0.0 through 7.0.2 may allow a remote authenticated attacker to read other devices\u0027 passwords in the audit log page.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-532\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-532\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiportal:7.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5B6AC446-7A55-4C21-87F0-9EE9958E1C39\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiportal:7.0.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2D011011-C5FD-437D-8551-15F54DE8602F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortiportal:7.0.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"28CE4B70-A451-43F7-B4D9-3EF4D4F5546E\"}]}]}],\"references\":[{\"url\":\"https://fortiguard.com/psirt/FG-IR-22-430\",\"source\":\"psirt@fortinet.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://fortiguard.com/psirt/FG-IR-22-430\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.