CVE-2022-24322 (GCVE-0-2022-24322)
Vulnerability from cvelistv5 – Published: 2022-03-09 23:05 – Updated: 2024-08-03 04:07- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure Control Expert |
Affected:
V15.0 SP1 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:07:02.429Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EcoStruxure Control Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "V15.0 SP1 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-09T23:05:13",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-24322",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EcoStruxure Control Expert",
"version": {
"version_data": [
{
"version_name": "V15.0 SP1",
"version_value": "and prior"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-24322",
"datePublished": "2022-03-09T23:05:13",
"dateReserved": "2022-02-02T00:00:00",
"dateUpdated": "2024-08-03T04:07:02.429Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"15.0\", \"matchCriteriaId\": \"43140BF9-455B-4E3C-BF5E-BB9BBF9802D2\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"A9BF2D84-901E-4D34-941F-FFAB85B0E9D3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:sp1:*:*:*:*:*:*\", \"matchCriteriaId\": \"939C02B6-B5C5-4F87-8179-4AFFE13FCFD2\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)\"}, {\"lang\": \"es\", \"value\": \"Una CWE-119: Se presenta una vulnerabilidad de Restricci\\u00f3n Inapropiada de las Operaciones dentro de los l\\u00edmites de un B\\u00fafer de Memoria que podr\\u00eda causar una interrupci\\u00f3n de la comunicaci\\u00f3n entre el controlador Modicon y el software de ingenier\\u00eda cuando un atacante es capaz de interceptar y manipular datos de respuesta Modbus espec\\u00edficos. Producto afectado: EcoStruxure Control Expert (versiones V15.0 SP1 y anteriores)\"}]",
"id": "CVE-2022-24322",
"lastModified": "2024-11-21T06:50:10.053",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.6, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 5.9, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.2, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:P/A:N\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2022-03-09T23:15:07.860",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-24322\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2022-03-09T23:15:07.860\",\"lastModified\":\"2024-11-21T06:50:10.053\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)\"},{\"lang\":\"es\",\"value\":\"Una CWE-119: Se presenta una vulnerabilidad de Restricci\u00f3n Inapropiada de las Operaciones dentro de los l\u00edmites de un B\u00fafer de Memoria que podr\u00eda causar una interrupci\u00f3n de la comunicaci\u00f3n entre el controlador Modicon y el software de ingenier\u00eda cuando un atacante es capaz de interceptar y manipular datos de respuesta Modbus espec\u00edficos. Producto afectado: EcoStruxure Control Expert (versiones V15.0 SP1 y anteriores)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.6,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.0\",\"matchCriteriaId\":\"43140BF9-455B-4E3C-BF5E-BB9BBF9802D2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"A9BF2D84-901E-4D34-941F-FFAB85B0E9D3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"939C02B6-B5C5-4F87-8179-4AFFE13FCFD2\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
GHSA-WWJR-J4CG-W355
Vulnerability from github – Published: 2022-03-11 00:02 – Updated: 2022-03-17 00:02A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)
{
"affected": [],
"aliases": [
"CVE-2022-24322"
],
"database_specific": {
"cwe_ids": [
"CWE-119"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-03-09T23:15:00Z",
"severity": "MODERATE"
},
"details": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)",
"id": "GHSA-wwjr-j4cg-w355",
"modified": "2022-03-17T00:02:09Z",
"published": "2022-03-11T00:02:37Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-24322"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"type": "CVSS_V3"
}
]
}
FKIE_CVE-2022-24322
Vulnerability from fkie_nvd - Published: 2022-03-09 23:15 - Updated: 2024-11-21 06:505.9 (Medium) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | ecostruxure_control_expert | * | |
| schneider-electric | ecostruxure_control_expert | 15.0 | |
| schneider-electric | ecostruxure_control_expert | 15.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
"matchCriteriaId": "43140BF9-455B-4E3C-BF5E-BB9BBF9802D2",
"versionEndExcluding": "15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*",
"matchCriteriaId": "A9BF2D84-901E-4D34-941F-FFAB85B0E9D3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:sp1:*:*:*:*:*:*",
"matchCriteriaId": "939C02B6-B5C5-4F87-8179-4AFFE13FCFD2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)"
},
{
"lang": "es",
"value": "Una CWE-119: Se presenta una vulnerabilidad de Restricci\u00f3n Inapropiada de las Operaciones dentro de los l\u00edmites de un B\u00fafer de Memoria que podr\u00eda causar una interrupci\u00f3n de la comunicaci\u00f3n entre el controlador Modicon y el software de ingenier\u00eda cuando un atacante es capaz de interceptar y manipular datos de respuesta Modbus espec\u00edficos. Producto afectado: EcoStruxure Control Expert (versiones V15.0 SP1 y anteriores)"
}
],
"id": "CVE-2022-24322",
"lastModified": "2024-11-21T06:50:10.053",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.6,
"impactScore": 3.6,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-03-09T23:15:07.860",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
VAR-202203-0231
Vulnerability from variot - Updated: 2022-05-04 09:37A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202203-0231",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ecostruxure control expert",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "15.0"
},
{
"model": "ecostruxure control expert",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": "15.0"
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-24322"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "15.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-24322"
}
]
},
"cve": "CVE-2022-24322",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "CVE-2022-24322",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.2,
"id": "CVE-2022-24322",
"impactScore": 3.6,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-24322",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202203-827",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202203-827"
},
{
"db": "NVD",
"id": "CVE-2022-24322"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-24322"
}
],
"trust": 1.0
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-24322",
"trust": 1.6
},
{
"db": "SCHNEIDER",
"id": "SEVD-2022-067-01",
"trust": 1.6
},
{
"db": "CNNVD",
"id": "CNNVD-202203-827",
"trust": 0.6
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202203-827"
},
{
"db": "NVD",
"id": "CVE-2022-24322"
}
]
},
"id": "VAR-202203-0231",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.7375
},
"last_update_date": "2022-05-04T09:37:30.855000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Schneider Electric EcoStruxure Control Experta Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=185690"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202203-827"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-24322"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2022-067-01"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-24322/"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202203-827"
},
{
"db": "NVD",
"id": "CVE-2022-24322"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNNVD",
"id": "CNNVD-202203-827"
},
{
"db": "NVD",
"id": "CVE-2022-24322"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-03-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202203-827"
},
{
"date": "2022-03-09T23:15:00",
"db": "NVD",
"id": "CVE-2022-24322"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-03-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202203-827"
},
{
"date": "2022-03-12T02:38:00",
"db": "NVD",
"id": "CVE-2022-24322"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202203-827"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric EcoStruxure Control Experta Buffer error vulnerability",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202203-827"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202203-827"
}
],
"trust": 0.6
}
}
GSD-2022-24322
Vulnerability from gsd - Updated: 2023-12-13 01:19{
"GSD": {
"alias": "CVE-2022-24322",
"description": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)",
"id": "GSD-2022-24322"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-24322"
],
"details": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)",
"id": "GSD-2022-24322",
"modified": "2023-12-13T01:19:43.101359Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-24322",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EcoStruxure Control Expert",
"version": {
"version_data": [
{
"version_name": "V15.0 SP1",
"version_value": "and prior"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "15.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-24322"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "N/A",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 3.6
}
},
"lastModifiedDate": "2022-03-12T02:38Z",
"publishedDate": "2022-03-09T23:15Z"
}
}
}
CERTFR-2022-AVI-546
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Conext ComBox toutes versions | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | CanBRASS versions antérieures à 7.6 | ||
| Schneider Electric | N/A | StruxureWare Data Center Expert versions antérieures à 7.9.1 | ||
| N/A | N/A | EcoStruxure Power Commission versions antérieures à 2.22 | ||
| Schneider Electric | N/A | Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Cybersecurity Admin Expert (CAE) versions antérieures à 2.4 | ||
| Schneider Electric | N/A | IGSS Data Server versions antérieures à 15.0.0.22170 | ||
| Schneider Electric | N/A | Geo SCADA Mobile versions antérieures au Build 202205171 | ||
| Schneider Electric | N/A | Smart-UPS SRT Series versions antérieures à 15.0 | ||
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | EcoStruxure Power Build: Rapsody Software versions antérieures à 2.1.13 | ||
| Schneider Electric | N/A | EPC2000 versions antérieures à 4.03 | ||
| Schneider Electric | N/A | Versadac versions antérieures à 2.43 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | SCADAPack RemoteConnect pour x70 versions antérieures à R2.7.3 | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500AC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Smart-UPS SCL Series versions antérieures à 15.1 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Conext ComBox toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "CanBRASS versions ant\u00e9rieures \u00e0 7.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "StruxureWare Data Center Expert versions ant\u00e9rieures \u00e0 7.9.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Commission versions ant\u00e9rieures \u00e0 2.22",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Cybersecurity Admin Expert (CAE) versions ant\u00e9rieures \u00e0 2.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Data Server versions ant\u00e9rieures \u00e0 15.0.0.22170",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Geo SCADA Mobile versions ant\u00e9rieures au Build 202205171",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SRT Series versions ant\u00e9rieures \u00e0 15.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build: Rapsody Software versions ant\u00e9rieures \u00e0 2.1.13",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EPC2000 versions ant\u00e9rieures \u00e0 4.03",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Versadac versions ant\u00e9rieures \u00e0 2.43",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SCADAPack RemoteConnect pour x70 versions ant\u00e9rieures \u00e0 R2.7.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500AC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SCL Series versions ant\u00e9rieures \u00e0 15.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-32524",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32524"
},
{
"name": "CVE-2022-24322",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24322"
},
{
"name": "CVE-2022-22731",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22731"
},
{
"name": "CVE-2022-32514",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32514"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-32517",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32517"
},
{
"name": "CVE-2022-32526",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32526"
},
{
"name": "CVE-2022-32530",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32530"
},
{
"name": "CVE-2022-32748",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32748"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2022-32529",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32529"
},
{
"name": "CVE-2022-32513",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32513"
},
{
"name": "CVE-2022-32747",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32747"
},
{
"name": "CVE-2022-32523",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32523"
},
{
"name": "CVE-2022-32528",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32528"
},
{
"name": "CVE-2022-32516",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32516"
},
{
"name": "CVE-2022-32522",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32522"
},
{
"name": "CVE-2022-32527",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32527"
},
{
"name": "CVE-2022-32515",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32515"
},
{
"name": "CVE-2021-22697",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22697"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2022-0223",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0223"
},
{
"name": "CVE-2022-32519",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32519"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2022-24323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24323"
},
{
"name": "CVE-2022-32512",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32512"
},
{
"name": "CVE-2022-32518",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32518"
},
{
"name": "CVE-2022-22732",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22732"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2022-32520",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32520"
},
{
"name": "CVE-2022-32525",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32525"
},
{
"name": "CVE-2021-22698",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22698"
},
{
"name": "CVE-2022-32521",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32521"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-546",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-06-15T00:00:00.000000"
},
{
"description": "Modification de la version des produits IGSS Data Server",
"revision_date": "2022-06-23T00:00:00.000000"
},
{
"description": "Mise \u00e0 jour du lien du bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022.",
"revision_date": "2022-08-19T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-02_APC-Smart-UPS_Security_Notification_V6.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-07 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-07_CanBRASS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-06 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-01 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-01_EcoStruxure_Control_Expert_and_EcoStruxure_Process_Expert_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-02 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-08 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-012-02 du 12 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-012-02_EcoStruxure_Power_Build_Rapsody_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-04 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_%20StruxureWare_Data_Center_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-01 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-05 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_Badalloc_Vulnerabilities_Security_Notification_V8.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-03 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
]
}
CERTFR-2022-AVI-546
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Conext ComBox toutes versions | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | CanBRASS versions antérieures à 7.6 | ||
| Schneider Electric | N/A | StruxureWare Data Center Expert versions antérieures à 7.9.1 | ||
| N/A | N/A | EcoStruxure Power Commission versions antérieures à 2.22 | ||
| Schneider Electric | N/A | Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Cybersecurity Admin Expert (CAE) versions antérieures à 2.4 | ||
| Schneider Electric | N/A | IGSS Data Server versions antérieures à 15.0.0.22170 | ||
| Schneider Electric | N/A | Geo SCADA Mobile versions antérieures au Build 202205171 | ||
| Schneider Electric | N/A | Smart-UPS SRT Series versions antérieures à 15.0 | ||
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | EcoStruxure Power Build: Rapsody Software versions antérieures à 2.1.13 | ||
| Schneider Electric | N/A | EPC2000 versions antérieures à 4.03 | ||
| Schneider Electric | N/A | Versadac versions antérieures à 2.43 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | SCADAPack RemoteConnect pour x70 versions antérieures à R2.7.3 | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500AC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Smart-UPS SCL Series versions antérieures à 15.1 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Conext ComBox toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "CanBRASS versions ant\u00e9rieures \u00e0 7.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "StruxureWare Data Center Expert versions ant\u00e9rieures \u00e0 7.9.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Commission versions ant\u00e9rieures \u00e0 2.22",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Cybersecurity Admin Expert (CAE) versions ant\u00e9rieures \u00e0 2.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Data Server versions ant\u00e9rieures \u00e0 15.0.0.22170",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Geo SCADA Mobile versions ant\u00e9rieures au Build 202205171",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SRT Series versions ant\u00e9rieures \u00e0 15.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build: Rapsody Software versions ant\u00e9rieures \u00e0 2.1.13",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EPC2000 versions ant\u00e9rieures \u00e0 4.03",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Versadac versions ant\u00e9rieures \u00e0 2.43",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SCADAPack RemoteConnect pour x70 versions ant\u00e9rieures \u00e0 R2.7.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500AC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SCL Series versions ant\u00e9rieures \u00e0 15.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-32524",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32524"
},
{
"name": "CVE-2022-24322",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24322"
},
{
"name": "CVE-2022-22731",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22731"
},
{
"name": "CVE-2022-32514",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32514"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-32517",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32517"
},
{
"name": "CVE-2022-32526",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32526"
},
{
"name": "CVE-2022-32530",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32530"
},
{
"name": "CVE-2022-32748",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32748"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2022-32529",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32529"
},
{
"name": "CVE-2022-32513",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32513"
},
{
"name": "CVE-2022-32747",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32747"
},
{
"name": "CVE-2022-32523",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32523"
},
{
"name": "CVE-2022-32528",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32528"
},
{
"name": "CVE-2022-32516",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32516"
},
{
"name": "CVE-2022-32522",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32522"
},
{
"name": "CVE-2022-32527",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32527"
},
{
"name": "CVE-2022-32515",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32515"
},
{
"name": "CVE-2021-22697",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22697"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2022-0223",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0223"
},
{
"name": "CVE-2022-32519",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32519"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2022-24323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24323"
},
{
"name": "CVE-2022-32512",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32512"
},
{
"name": "CVE-2022-32518",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32518"
},
{
"name": "CVE-2022-22732",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22732"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2022-32520",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32520"
},
{
"name": "CVE-2022-32525",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32525"
},
{
"name": "CVE-2021-22698",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22698"
},
{
"name": "CVE-2022-32521",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32521"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-546",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-06-15T00:00:00.000000"
},
{
"description": "Modification de la version des produits IGSS Data Server",
"revision_date": "2022-06-23T00:00:00.000000"
},
{
"description": "Mise \u00e0 jour du lien du bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022.",
"revision_date": "2022-08-19T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-02_APC-Smart-UPS_Security_Notification_V6.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-07 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-07_CanBRASS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-06 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-01 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-01_EcoStruxure_Control_Expert_and_EcoStruxure_Process_Expert_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-02 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-08 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-012-02 du 12 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-012-02_EcoStruxure_Power_Build_Rapsody_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-04 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_%20StruxureWare_Data_Center_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-01 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-05 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_Badalloc_Vulnerabilities_Security_Notification_V8.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-03 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
]
}
CERTFR-2022-AVI-215
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
- EcoStruxure Control Expert versions antérieures à 15.1
- EcoStruxure Process Expert versions antérieures à 2021
- SCADAPack RemoteConnect for x70 toutes versions, se référer aux mesures de contournement proposées par l'éditeur
- Smart-UPS séries SMT micrologiciels versions antérieures à UPS 04.6 permettant une correction partielle de la vulnérabilité CVE-2022-0715 et une correction des vulnérabilités CVE-2022-22805 et CVE-2022-22806
- Smart-UPS séries SMC micrologiciels versions antérieures à UPS 04.3 permettant une correction partielle de la vulnérabilité CVE-2022-0715 et une correction des vulnérabilités CVE-2022-22805 et CVE-2022-22806
- Aucun correctif n'est disponible pour les séries Smart-UPS SCL, SMX et SRT ainsi que les séries SmartConnect SMTL, SCL, et SMX. Se référer aux mesures de contournement proposées par l'éditeur
- Ritto Wiser Door toutes versions, se référer aux mesures de contournement proposées par l'éditeur
Pour les vulnérabilités identifiées CVE-2021-22778, CVE-2021-22780, CVE-2021-22781, CVE-2021-22782 et CVE-2020-12525, la mise à niveau vers EcoStruxure Control Expert v15.1 et EcoStruxure Process Expert v2021 constitue une première étape de contournement. L'éditeur annoncera la publication d'un nouveau micrologiciel afin de corriger ces vulnérabilités.
| Vendor | Product | Description |
|---|
| Title | Publication Time | Tags | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [],
"affected_systems_content": "\u003cul\u003e \u003cli\u003eEcoStruxure Control Expert versions ant\u00e9rieures \u00e0 15.1\u003c/li\u003e \u003cli\u003eEcoStruxure Process Expert versions ant\u00e9rieures \u00e0 2021\u003c/li\u003e \u003cli\u003eSCADAPack RemoteConnect for x70 toutes versions, se r\u00e9f\u00e9rer aux mesures de contournement propos\u00e9es par l\u0027\u00e9diteur\u003c/li\u003e \u003cli\u003eSmart-UPS s\u00e9ries SMT micrologiciels versions ant\u00e9rieures \u00e0 UPS 04.6 permettant une correction partielle de la vuln\u00e9rabilit\u00e9 CVE-2022-0715 et une correction des vuln\u00e9rabilit\u00e9s CVE-2022-22805 et CVE-2022-22806\u003c/li\u003e \u003cli\u003eSmart-UPS s\u00e9ries SMC micrologiciels versions ant\u00e9rieures \u00e0 UPS 04.3 permettant une correction partielle de la vuln\u00e9rabilit\u00e9 CVE-2022-0715 et une correction des vuln\u00e9rabilit\u00e9s CVE-2022-22805 et CVE-2022-22806\u003c/li\u003e \u003cli\u003eAucun correctif n\u0027est disponible pour les s\u00e9ries Smart-UPS SCL, SMX et SRT ainsi que les s\u00e9ries SmartConnect SMTL, SCL, et SMX. Se r\u00e9f\u00e9rer aux mesures de contournement propos\u00e9es par l\u0027\u00e9diteur\u003c/li\u003e \u003cli\u003eRitto Wiser Door toutes versions, se r\u00e9f\u00e9rer aux mesures de contournement propos\u00e9es par l\u0027\u00e9diteur\u003c/li\u003e \u003c/ul\u003e \u003cp\u003ePour les vuln\u00e9rabilit\u00e9s identifi\u00e9es CVE-2021-22778, CVE-2021-22780, CVE-2021-22781, CVE-2021-22782 et CVE-2020-12525, la mise \u00e0 niveau vers EcoStruxure Control Expert v15.1 et EcoStruxure Process Expert v2021 constitue une premi\u00e8re \u00e9tape de contournement. L\u0027\u00e9diteur annoncera la publication d\u0027un nouveau micrologiciel afin de corriger ces vuln\u00e9rabilit\u00e9s.\u003c/p\u003e ",
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-24322",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24322"
},
{
"name": "CVE-2021-21814",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21814"
},
{
"name": "CVE-2021-34527",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-34527"
},
{
"name": "CVE-2021-21830",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21830"
},
{
"name": "CVE-2021-22797",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22797"
},
{
"name": "CVE-2021-22779",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22779"
},
{
"name": "CVE-2021-22781",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22781"
},
{
"name": "CVE-2021-22780",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22780"
},
{
"name": "CVE-2021-21828",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21828"
},
{
"name": "CVE-2021-21810",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21810"
},
{
"name": "CVE-2021-21813",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21813"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2021-21825",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21825"
},
{
"name": "CVE-2021-21829",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21829"
},
{
"name": "CVE-2021-1675",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-1675"
},
{
"name": "CVE-2021-22782",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22782"
},
{
"name": "CVE-2021-22778",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22778"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2021-21826",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21826"
},
{
"name": "CVE-2021-21812",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21812"
},
{
"name": "CVE-2021-21827",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21827"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2022-24323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24323"
},
{
"name": "CVE-2021-21815",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21815"
},
{
"name": "CVE-2021-22783",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22783"
},
{
"name": "CVE-2021-21811",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21811"
},
{
"name": "CVE-2020-12525",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12525"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-215",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-03-08T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 8 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-04 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-257-01 du 14 septembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-222-02 du 10 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-01 du 8 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-03 du 8 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider 2021-194-01 du 13 juillet 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01"
}
]
}
CERTFR-2022-AVI-215
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
- EcoStruxure Control Expert versions antérieures à 15.1
- EcoStruxure Process Expert versions antérieures à 2021
- SCADAPack RemoteConnect for x70 toutes versions, se référer aux mesures de contournement proposées par l'éditeur
- Smart-UPS séries SMT micrologiciels versions antérieures à UPS 04.6 permettant une correction partielle de la vulnérabilité CVE-2022-0715 et une correction des vulnérabilités CVE-2022-22805 et CVE-2022-22806
- Smart-UPS séries SMC micrologiciels versions antérieures à UPS 04.3 permettant une correction partielle de la vulnérabilité CVE-2022-0715 et une correction des vulnérabilités CVE-2022-22805 et CVE-2022-22806
- Aucun correctif n'est disponible pour les séries Smart-UPS SCL, SMX et SRT ainsi que les séries SmartConnect SMTL, SCL, et SMX. Se référer aux mesures de contournement proposées par l'éditeur
- Ritto Wiser Door toutes versions, se référer aux mesures de contournement proposées par l'éditeur
Pour les vulnérabilités identifiées CVE-2021-22778, CVE-2021-22780, CVE-2021-22781, CVE-2021-22782 et CVE-2020-12525, la mise à niveau vers EcoStruxure Control Expert v15.1 et EcoStruxure Process Expert v2021 constitue une première étape de contournement. L'éditeur annoncera la publication d'un nouveau micrologiciel afin de corriger ces vulnérabilités.
| Vendor | Product | Description |
|---|
| Title | Publication Time | Tags | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [],
"affected_systems_content": "\u003cul\u003e \u003cli\u003eEcoStruxure Control Expert versions ant\u00e9rieures \u00e0 15.1\u003c/li\u003e \u003cli\u003eEcoStruxure Process Expert versions ant\u00e9rieures \u00e0 2021\u003c/li\u003e \u003cli\u003eSCADAPack RemoteConnect for x70 toutes versions, se r\u00e9f\u00e9rer aux mesures de contournement propos\u00e9es par l\u0027\u00e9diteur\u003c/li\u003e \u003cli\u003eSmart-UPS s\u00e9ries SMT micrologiciels versions ant\u00e9rieures \u00e0 UPS 04.6 permettant une correction partielle de la vuln\u00e9rabilit\u00e9 CVE-2022-0715 et une correction des vuln\u00e9rabilit\u00e9s CVE-2022-22805 et CVE-2022-22806\u003c/li\u003e \u003cli\u003eSmart-UPS s\u00e9ries SMC micrologiciels versions ant\u00e9rieures \u00e0 UPS 04.3 permettant une correction partielle de la vuln\u00e9rabilit\u00e9 CVE-2022-0715 et une correction des vuln\u00e9rabilit\u00e9s CVE-2022-22805 et CVE-2022-22806\u003c/li\u003e \u003cli\u003eAucun correctif n\u0027est disponible pour les s\u00e9ries Smart-UPS SCL, SMX et SRT ainsi que les s\u00e9ries SmartConnect SMTL, SCL, et SMX. Se r\u00e9f\u00e9rer aux mesures de contournement propos\u00e9es par l\u0027\u00e9diteur\u003c/li\u003e \u003cli\u003eRitto Wiser Door toutes versions, se r\u00e9f\u00e9rer aux mesures de contournement propos\u00e9es par l\u0027\u00e9diteur\u003c/li\u003e \u003c/ul\u003e \u003cp\u003ePour les vuln\u00e9rabilit\u00e9s identifi\u00e9es CVE-2021-22778, CVE-2021-22780, CVE-2021-22781, CVE-2021-22782 et CVE-2020-12525, la mise \u00e0 niveau vers EcoStruxure Control Expert v15.1 et EcoStruxure Process Expert v2021 constitue une premi\u00e8re \u00e9tape de contournement. L\u0027\u00e9diteur annoncera la publication d\u0027un nouveau micrologiciel afin de corriger ces vuln\u00e9rabilit\u00e9s.\u003c/p\u003e ",
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-24322",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24322"
},
{
"name": "CVE-2021-21814",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21814"
},
{
"name": "CVE-2021-34527",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-34527"
},
{
"name": "CVE-2021-21830",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21830"
},
{
"name": "CVE-2021-22797",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22797"
},
{
"name": "CVE-2021-22779",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22779"
},
{
"name": "CVE-2021-22781",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22781"
},
{
"name": "CVE-2021-22780",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22780"
},
{
"name": "CVE-2021-21828",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21828"
},
{
"name": "CVE-2021-21810",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21810"
},
{
"name": "CVE-2021-21813",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21813"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2021-21825",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21825"
},
{
"name": "CVE-2021-21829",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21829"
},
{
"name": "CVE-2021-1675",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-1675"
},
{
"name": "CVE-2021-22782",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22782"
},
{
"name": "CVE-2021-22778",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22778"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2021-21826",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21826"
},
{
"name": "CVE-2021-21812",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21812"
},
{
"name": "CVE-2021-21827",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21827"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2022-24323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24323"
},
{
"name": "CVE-2021-21815",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21815"
},
{
"name": "CVE-2021-22783",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22783"
},
{
"name": "CVE-2021-21811",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21811"
},
{
"name": "CVE-2020-12525",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12525"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-215",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-03-08T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 8 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-04 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-257-01 du 14 septembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-222-02 du 10 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-01 du 8 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-03 du 8 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider 2021-194-01 du 13 juillet 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01"
}
]
}
CVE-2022-24322
Vulnerability from csaf_se - Published: 2022-03-08 18:30 - Updated: 2022-06-14 18:30Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure\u2122 Control Expert, EcoStruxure\u2122 Process Expert, SCADAPack RemoteConnect\u2122 for x70 software products.\r\nEcoStruxure\u2122 Control Expert is the common programming, debugging and operating software for Modicon M340, M580, M580S, Premium, Momentum and Quantum ranges. \r\nEcoStruxure\u2122 Process Expert is the next-generation process automation system to engineer, operate and maintain an entire plant, a Distributed Control System (DCS), designed especially for water, mining, cement, power generation, consumer packaged goods, chemical, and oil and gas applications. \r\nThe SCADAPack RemoteConnect\u2122 for x70 product is a Windows-based application based on EcoStruxure\u2122 Control Expert software components that provides a programming and configuration environment for the SCADAPack x70 RTU series, which is comprised of the SCADAPack 470, 474, 570, 574 and 575 Smart RTUs.\r\nFailure to apply the remediations provided below may risk a Denial of Service attack, which could cause a disruption of communication between the Modicon controller and the engineering software.\r\n\r\nJune 2022 Update: Added SCADAPack RemoteConnect\u2122 to the list of affected products, which is impacted on versions prior to R2.7.3 through the integration of EcoStruxure\u2122 Control Expert.\r\n",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cybersecurity@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "EcoStruxureTM Control Expert, EcoStruxureTM Process Expert, SCADAPack RemoteConnect\u2122 for x70 - SEVD-2022-067-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2022-067-01.json"
},
{
"category": "self",
"summary": "EcoStruxureTM Control Expert, EcoStruxureTM Process Expert, SCADAPack RemoteConnect\u2122 for x70 - SEVD-2022-067-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-01_EcoStruxure_Control_Expert_and_EcoStruxure_Process_Expert_Security_Notification_V2.0.pdf"
},
{
"category": "self",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "EcoStruxureTM Control Expert, EcoStruxureTM Process Expert, SCADAPack RemoteConnect\u2122 for x70",
"tracking": {
"current_release_date": "2022-06-14T18:30:00.000Z",
"generator": {
"date": "2022-07-19T14:47:03.421Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.1"
}
},
"id": "SEVD-2022-067-01",
"initial_release_date": "2022-03-08T18:30:00.000Z",
"revision_history": [
{
"date": "2022-03-08T18:30:00.000Z",
"number": "1",
"summary": "Orignal Release"
},
{
"date": "2022-06-14T11:01:01.000Z",
"number": "2",
"summary": "Added SCADAPack RemoteConnect\u2122 to the list of affected products, which is impacted on versions prior to R2.7.3 through the integration of EcoStruxure\u2122 Control Expert."
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=V15.0 SP1",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 Control Expert \u003c=V15.0 SP1",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Control Expert"
},
{
"branches": [
{
"category": "product_version",
"name": "V15.1",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 Control Expert V15.1",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Control Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2021",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 Process Expert \u003cV2021",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Process Expert"
},
{
"branches": [
{
"category": "product_version",
"name": "2021",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 Process Expert 2021",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Process Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cR2.7.3",
"product": {
"name": "Schneider Electric SCADAPack RemoteConnect\u2122 for x70 \u003cR2.7.3",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SCADAPack RemoteConnect\u2122 for x70"
},
{
"branches": [
{
"category": "product_version",
"name": "R2.7.3",
"product": {
"name": "Schneider Electric SCADAPack RemoteConnect\u2122 for x70 R2.7.3",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SCADAPack RemoteConnect\u2122 for x70"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Jiie Chen"
],
"organization": "NSFOCUS"
}
],
"cve": "CVE-2022-24322",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "description",
"text": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2",
"6"
],
"known_affected": [
"1",
"5"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 15.1 of EcoStruxure\u2122 Control Expert includes a fix for these vulnerabilities and is available for download here:\r\n\r\nhttps://www.se.com/ww/en/download/document/EcoStruxureControlExpert_V15.1/\r\n\r\nCustomers using Unity Pro should strongly consider migrating to EcoStruxure\u2122 Control Expert. \r\n\r\nIf customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \r\nTo mitigate the risks associated to Modbus weaknesses, users should immediately:\r\n\u2022\tSetup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP\r\n",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_V15.1/"
},
{
"category": "vendor_fix",
"details": "Version R2.7.3 of SCADAPack RemoteConnect includes a fix for this vulnerability and is available for download here: \r\nRemoteConnect for the SCADAPack x70 | Schneider Electric Exchange Marketplace (se.com)\r\nThere is no need to reboot\r\nUsers no longer need to update the RemoteConnect application when there is a Control Expert update\r\nIf customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \r\nTo mitigate the risks associated to Modbus weaknesses, users should immediately:\r\n\u2022\tSetup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP \r\n",
"product_ids": [
"5"
],
"restart_required": {
"category": "none"
},
"url": "https://shop.exchange.se.com/en-US/apps/58663"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"1",
"5"
]
}
],
"title": "CVE-2022-24322"
},
{
"acknowledgments": [
{
"organization": "CNCERT"
}
],
"cve": "CVE-2022-24323",
"cwe": {
"id": "CWE-754",
"name": "Improper Check for Unusual or Exceptional Conditions"
},
"notes": [
{
"category": "description",
"text": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2",
"4",
"6"
],
"known_affected": [
"1",
"3",
"5"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 15.1 of EcoStruxure\u2122 Control Expert includes a fix for these vulnerabilities and is available for download here:\r\n\r\nhttps://www.se.com/ww/en/download/document/EcoStruxureControlExpert_V15.1/\r\n\r\nCustomers using Unity Pro should strongly consider migrating to EcoStruxure\u2122 Control Expert. \r\n\r\nIf customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \r\nTo mitigate the risks associated to Modbus weaknesses, users should immediately:\r\n\u2022\tSetup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP\r\n",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_V15.1/"
},
{
"category": "vendor_fix",
"details": "Version 2021 of EcoStruxure\u2122 Process Expert includes a fix for these vulnerabilities and is available for download here:\r\n\r\nhttps://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release\r\n \r\nIt is recommended to first read the ReadMe in its entirety before proceeding with the software installation. \r\n\r\nIf customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \r\nTo mitigate the risks associated to Modbus weaknesses, users should immediately:\r\n\u2022\tSetup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP\r\n",
"product_ids": [
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/myschneider/documentsDownloadCenterDetail/in/en/EPE2021Release"
},
{
"category": "vendor_fix",
"details": "Version R2.7.3 of SCADAPack RemoteConnect includes a fix for this vulnerability and is available for download here: \r\nRemoteConnect for the SCADAPack x70 | Schneider Electric Exchange Marketplace (se.com)\r\nThere is no need to reboot\r\nUsers no longer need to update the RemoteConnect application when there is a Control Expert update\r\nIf customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: \r\nTo mitigate the risks associated to Modbus weaknesses, users should immediately:\r\n\u2022\tSetup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP \r\n",
"product_ids": [
"5"
],
"restart_required": {
"category": "none"
},
"url": "https://shop.exchange.se.com/en-US/apps/58663"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"1",
"3",
"5"
]
}
],
"title": "CVE-2022-24323"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.