CVE-2022-22723 (GCVE-0-2022-22723)
Vulnerability from cvelistv5 – Published: 2022-02-04 22:29 – Updated: 2024-08-03 03:21- CWE-120 - Buffer Copy without Checking Size of Input
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Easergy P5 (All firmware versions prior to V01.401.101) |
Affected:
Easergy P5 (All firmware versions prior to V01.401.101)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:21:49.023Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Easergy P5 (All firmware versions prior to V01.401.101)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Easergy P5 (All firmware versions prior to V01.401.101)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-04T22:29:35",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-22723",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Easergy P5 (All firmware versions prior to V01.401.101)",
"version": {
"version_data": [
{
"version_value": "Easergy P5 (All firmware versions prior to V01.401.101)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-120: Buffer Copy without Checking Size of Input"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-22723",
"datePublished": "2022-02-04T22:29:35",
"dateReserved": "2022-01-06T00:00:00",
"dateUpdated": "2024-08-03T03:21:49.023Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:easergy_p5_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"01.401.101\", \"matchCriteriaId\": \"5F339D52-8956-44D7-B9A3-5E33CF93F014\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:easergy_p5:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D642DB0E-55FF-430D-BD45-D305B13A5045\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101)\"}, {\"lang\": \"es\", \"value\": \"Una CWE-120: Se presenta una vulnerabilidad de Copia del B\\u00fafer sin Comprobar el Tama\\u00f1o de la Entrada que podr\\u00eda conllevar a un desbordamiento del b\\u00fafer causando un bloqueo del programa y una ejecuci\\u00f3n de c\\u00f3digo arbitrario cuando son enviados paquetes especialmente dise\\u00f1ados al dispositivo a trav\\u00e9s de la red. Las funciones Protection y la funci\\u00f3n tripping por medio de GOOSE pueden verse afectadas. Producto afectado: Easergy P5 (todas las versiones de firmware anteriores a V01.401.101)\"}]",
"id": "CVE-2022-22723",
"lastModified": "2024-11-21T06:47:19.553",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:A/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 8.3, \"accessVector\": \"ADJACENT_NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 6.5, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2022-02-04T23:15:13.113",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-120\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-22723\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2022-02-04T23:15:13.113\",\"lastModified\":\"2024-11-21T06:47:19.553\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101)\"},{\"lang\":\"es\",\"value\":\"Una CWE-120: Se presenta una vulnerabilidad de Copia del B\u00fafer sin Comprobar el Tama\u00f1o de la Entrada que podr\u00eda conllevar a un desbordamiento del b\u00fafer causando un bloqueo del programa y una ejecuci\u00f3n de c\u00f3digo arbitrario cuando son enviados paquetes especialmente dise\u00f1ados al dispositivo a trav\u00e9s de la red. Las funciones Protection y la funci\u00f3n tripping por medio de GOOSE pueden verse afectadas. Producto afectado: Easergy P5 (todas las versiones de firmware anteriores a V01.401.101)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":8.3,\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":6.5,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:easergy_p5_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"01.401.101\",\"matchCriteriaId\":\"5F339D52-8956-44D7-B9A3-5E33CF93F014\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:easergy_p5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D642DB0E-55FF-430D-BD45-D305B13A5045\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
VAR-202201-0617
Vulnerability from variot - Updated: 2024-02-13 22:43A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101). Easergy P5 Contains a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Schneider Electric Easergy P5 is a protection relay from Schneider Electric, France, for demanding medium voltage applications.
A buffer overflow vulnerability exists in Schneider Electric Easergy P5, which exists due to a boundary error when handling untrusted input. An attacker could exploit this vulnerability to execute arbitrary code on the system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202201-0617",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "easergy p5",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "01.401.101"
},
{
"model": "easergy p5",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "easergy p5",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": "easergy p5 firmware 01.401.101"
},
{
"model": "electric easergy p5",
"scope": "lt",
"trust": 0.6,
"vendor": "schneider",
"version": "01.401.101"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-70104"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001378"
},
{
"db": "NVD",
"id": "CVE-2022-22723"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:easergy_p5_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "01.401.101",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:easergy_p5:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-22723"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Paul Noalhyt, and Yuanzhe Wu at Red Balloon Security reported these vulnerabilities to CISA.,Timoth\u00e9e Chauvin",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202201-940"
}
],
"trust": 0.6
},
"cve": "CVE-2022-22723",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.5,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Adjacent Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 8.3,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2022-22723",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.5,
"id": "CNVD-2022-70104",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-22723",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-22723",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2022-70104",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202201-940",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2022-22723",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-70104"
},
{
"db": "VULMON",
"id": "CVE-2022-22723"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001378"
},
{
"db": "CNNVD",
"id": "CNNVD-202201-940"
},
{
"db": "NVD",
"id": "CVE-2022-22723"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101). Easergy P5 Contains a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Schneider Electric Easergy P5 is a protection relay from Schneider Electric, France, for demanding medium voltage applications. \n\r\n\r\nA buffer overflow vulnerability exists in Schneider Electric Easergy P5, which exists due to a boundary error when handling untrusted input. An attacker could exploit this vulnerability to execute arbitrary code on the system",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-22723"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001378"
},
{
"db": "CNVD",
"id": "CNVD-2022-70104"
},
{
"db": "VULMON",
"id": "CVE-2022-22723"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-22723",
"trust": 3.9
},
{
"db": "SCHNEIDER",
"id": "SEVD-2022-011-03",
"trust": 1.7
},
{
"db": "ICS CERT",
"id": "ICSA-22-055-03",
"trust": 1.5
},
{
"db": "JVN",
"id": "JVNVU95341726",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001378",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-70104",
"trust": 0.6
},
{
"db": "CS-HELP",
"id": "SB2022011209",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2022.0825",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202201-940",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-22723",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-70104"
},
{
"db": "VULMON",
"id": "CVE-2022-22723"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001378"
},
{
"db": "CNNVD",
"id": "CNNVD-202201-940"
},
{
"db": "NVD",
"id": "CVE-2022-22723"
}
]
},
"id": "VAR-202201-0617",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-70104"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-70104"
}
]
},
"last_update_date": "2024-02-13T22:43:18.764000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SEVD-2022-011-03",
"trust": 0.8,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2022-011-03"
},
{
"title": "CVE-2022-XXXX",
"trust": 0.1,
"url": "https://github.com/alphabugx/cve-2022-23305 "
},
{
"title": "CVE-2022-XXXX",
"trust": 0.1,
"url": "https://github.com/alphabugx/cve-2022-rce "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2022-22723"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001378"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "Classic buffer overflow (CWE-120) [ Other ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-001378"
},
{
"db": "NVD",
"id": "CVE-2022-22723"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-22723"
},
{
"trust": 1.7,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2022-011-03"
},
{
"trust": 0.9,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-055-03"
},
{
"trust": 0.8,
"url": "http://jvn.jp/vu/jvnvu95341726/index.html"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022011209"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2022.0825"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-055-03"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/120.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://github.com/alphabugx/cve-2022-23305"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-70104"
},
{
"db": "VULMON",
"id": "CVE-2022-22723"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001378"
},
{
"db": "CNNVD",
"id": "CNNVD-202201-940"
},
{
"db": "NVD",
"id": "CVE-2022-22723"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-70104"
},
{
"db": "VULMON",
"id": "CVE-2022-22723"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001378"
},
{
"db": "CNNVD",
"id": "CNNVD-202201-940"
},
{
"db": "NVD",
"id": "CVE-2022-22723"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-10-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-70104"
},
{
"date": "2022-02-04T00:00:00",
"db": "VULMON",
"id": "CVE-2022-22723"
},
{
"date": "2022-02-28T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-001378"
},
{
"date": "2022-01-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202201-940"
},
{
"date": "2022-02-04T23:15:13.113000",
"db": "NVD",
"id": "CVE-2022-22723"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-10-20T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-70104"
},
{
"date": "2022-02-10T00:00:00",
"db": "VULMON",
"id": "CVE-2022-22723"
},
{
"date": "2022-02-28T08:50:00",
"db": "JVNDB",
"id": "JVNDB-2022-001378"
},
{
"date": "2022-02-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202201-940"
},
{
"date": "2022-02-10T06:57:39.443000",
"db": "NVD",
"id": "CVE-2022-22723"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202201-940"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Easergy\u00a0P5\u00a0 Buffer Overflow Vulnerability in Linux",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-001378"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202201-940"
}
],
"trust": 0.6
}
}
CERTFR-2022-AVI-017
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | Easergy P5, versions antérieures à 01.401.101, se référer aux informations fournies par l'éditeur pour appliquer les mesures de contournement | ||
| N/A | N/A | ConneXium Tofino Firewall TCSEFEA23F3F20 et 21, toutes versions. Ces produits ne sont plus maintenus par l'éditeur qui incite fortement à mettre à jour vers la gamme TCSEFA23F3F22 | ||
| Schneider Electric | N/A | ConneXium Tofino OPC-LSM TCSEFM0000, versions antérieures à 03.23 | ||
| N/A | N/A | CODESYS V3, vérifier l'avis SEVD-2022-011-06 pour identifier les périphériques utilisant ce système d'exploitation et appliquer les mesures de contournement suggérées par l'éditeur | ||
| N/A | N/A | Easergy T300, versions antérieures à 2.7.1 | ||
| Schneider Electric | N/A | Easergy P3, versions antérieures à 30.205, se référer aux informations fournies par l'éditeur pour appliquer les mesures de contournement | ||
| Schneider Electric | N/A | EcoStruxure Power Monitoring Expert 2020, versions antérieures à 2020 CU3 sans le composant Floating License Manager 2.7 | ||
| Schneider Electric | N/A | ConneXium Tofino Firewall TCSEFEA23F3F22, versions antérieures à 03.23 | ||
| Schneider Electric | Modicon M340 | Modicon M340 Quantum et Premium Quantum CPUs, vérifier l'avis SEVD-2022-011-01 pour identifier les autres systèmes Modicon vulnérables et appliquer les mesures de contournement suggérées par l'éditeur | ||
| Schneider Electric | N/A | EcoStruxure Power Monitoring Expert 9.0, toutes versions. Ces produits ne sont plus maintenus par l'éditeur qui incite fortement à mettre à jour vers la gamme Power Monitoring Expert 2021 |
| Title | Publication Time | Tags | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Easergy P5, versions ant\u00e9rieures \u00e0 01.401.101, se r\u00e9f\u00e9rer aux informations fournies par l\u0027\u00e9diteur pour appliquer les mesures de contournement",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ConneXium Tofino Firewall TCSEFEA23F3F20 et 21, toutes versions. Ces produits ne sont plus maintenus par l\u0027\u00e9diteur qui incite fortement \u00e0 mettre \u00e0 jour vers la gamme TCSEFA23F3F22",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ConneXium Tofino OPC-LSM TCSEFM0000, versions ant\u00e9rieures \u00e0 03.23",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "CODESYS V3, v\u00e9rifier l\u0027avis SEVD-2022-011-06 pour identifier les p\u00e9riph\u00e9riques utilisant ce syst\u00e8me d\u0027exploitation et appliquer les mesures de contournement sugg\u00e9r\u00e9es par l\u0027\u00e9diteur",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Easergy T300, versions ant\u00e9rieures \u00e0 2.7.1",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Easergy P3, versions ant\u00e9rieures \u00e0 30.205, se r\u00e9f\u00e9rer aux informations fournies par l\u0027\u00e9diteur pour appliquer les mesures de contournement",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert 2020, versions ant\u00e9rieures \u00e0 2020 CU3 sans le composant Floating License Manager 2.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "ConneXium Tofino Firewall TCSEFEA23F3F22, versions ant\u00e9rieures \u00e0 03.23",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 Quantum et Premium Quantum CPUs, v\u00e9rifier l\u0027avis SEVD-2022-011-01 pour identifier les autres syst\u00e8mes Modicon vuln\u00e9rables et appliquer les mesures de contournement sugg\u00e9r\u00e9es par l\u0027\u00e9diteur",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert 9.0, toutes versions. Ces produits ne sont plus maintenus par l\u0027\u00e9diteur qui incite fortement \u00e0 mettre \u00e0 jour vers la gamme Power Monitoring Expert 2021",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-22723",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22723"
},
{
"name": "CVE-2021-21869",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21869"
},
{
"name": "CVE-2021-21866",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21866"
},
{
"name": "CVE-2021-30066",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30066"
},
{
"name": "CVE-2021-30064",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30064"
},
{
"name": "CVE-2022-22724",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22724"
},
{
"name": "CVE-2019-8963",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8963"
},
{
"name": "CVE-2021-30063",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30063"
},
{
"name": "CVE-2021-30061",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30061"
},
{
"name": "CVE-2021-21863",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21863"
},
{
"name": "CVE-2022-22722",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22722"
},
{
"name": "CVE-2021-21865",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21865"
},
{
"name": "CVE-2020-7534",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7534"
},
{
"name": "CVE-2021-21867",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21867"
},
{
"name": "CVE-2022-22804",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22804"
},
{
"name": "CVE-2021-30062",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30062"
},
{
"name": "CVE-2022-22726",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22726"
},
{
"name": "CVE-2022-22725",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22725"
},
{
"name": "CVE-2021-29241",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29241"
},
{
"name": "CVE-2020-8597",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8597"
},
{
"name": "CVE-2021-29240",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29240"
},
{
"name": "CVE-2022-22727",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22727"
},
{
"name": "CVE-2021-21864",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21864"
},
{
"name": "CVE-2021-21868",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21868"
},
{
"name": "CVE-2021-30065",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30065"
},
{
"name": "CVE-2021-33485",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33485"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-017",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-01-11T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-07 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-03 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-04 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-01 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-02 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-05 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-06 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-06"
}
]
}
CERTFR-2022-AVI-017
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | Easergy P5, versions antérieures à 01.401.101, se référer aux informations fournies par l'éditeur pour appliquer les mesures de contournement | ||
| N/A | N/A | ConneXium Tofino Firewall TCSEFEA23F3F20 et 21, toutes versions. Ces produits ne sont plus maintenus par l'éditeur qui incite fortement à mettre à jour vers la gamme TCSEFA23F3F22 | ||
| Schneider Electric | N/A | ConneXium Tofino OPC-LSM TCSEFM0000, versions antérieures à 03.23 | ||
| N/A | N/A | CODESYS V3, vérifier l'avis SEVD-2022-011-06 pour identifier les périphériques utilisant ce système d'exploitation et appliquer les mesures de contournement suggérées par l'éditeur | ||
| N/A | N/A | Easergy T300, versions antérieures à 2.7.1 | ||
| Schneider Electric | N/A | Easergy P3, versions antérieures à 30.205, se référer aux informations fournies par l'éditeur pour appliquer les mesures de contournement | ||
| Schneider Electric | N/A | EcoStruxure Power Monitoring Expert 2020, versions antérieures à 2020 CU3 sans le composant Floating License Manager 2.7 | ||
| Schneider Electric | N/A | ConneXium Tofino Firewall TCSEFEA23F3F22, versions antérieures à 03.23 | ||
| Schneider Electric | Modicon M340 | Modicon M340 Quantum et Premium Quantum CPUs, vérifier l'avis SEVD-2022-011-01 pour identifier les autres systèmes Modicon vulnérables et appliquer les mesures de contournement suggérées par l'éditeur | ||
| Schneider Electric | N/A | EcoStruxure Power Monitoring Expert 9.0, toutes versions. Ces produits ne sont plus maintenus par l'éditeur qui incite fortement à mettre à jour vers la gamme Power Monitoring Expert 2021 |
| Title | Publication Time | Tags | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Easergy P5, versions ant\u00e9rieures \u00e0 01.401.101, se r\u00e9f\u00e9rer aux informations fournies par l\u0027\u00e9diteur pour appliquer les mesures de contournement",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ConneXium Tofino Firewall TCSEFEA23F3F20 et 21, toutes versions. Ces produits ne sont plus maintenus par l\u0027\u00e9diteur qui incite fortement \u00e0 mettre \u00e0 jour vers la gamme TCSEFA23F3F22",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ConneXium Tofino OPC-LSM TCSEFM0000, versions ant\u00e9rieures \u00e0 03.23",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "CODESYS V3, v\u00e9rifier l\u0027avis SEVD-2022-011-06 pour identifier les p\u00e9riph\u00e9riques utilisant ce syst\u00e8me d\u0027exploitation et appliquer les mesures de contournement sugg\u00e9r\u00e9es par l\u0027\u00e9diteur",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Easergy T300, versions ant\u00e9rieures \u00e0 2.7.1",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Easergy P3, versions ant\u00e9rieures \u00e0 30.205, se r\u00e9f\u00e9rer aux informations fournies par l\u0027\u00e9diteur pour appliquer les mesures de contournement",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert 2020, versions ant\u00e9rieures \u00e0 2020 CU3 sans le composant Floating License Manager 2.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "ConneXium Tofino Firewall TCSEFEA23F3F22, versions ant\u00e9rieures \u00e0 03.23",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 Quantum et Premium Quantum CPUs, v\u00e9rifier l\u0027avis SEVD-2022-011-01 pour identifier les autres syst\u00e8mes Modicon vuln\u00e9rables et appliquer les mesures de contournement sugg\u00e9r\u00e9es par l\u0027\u00e9diteur",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert 9.0, toutes versions. Ces produits ne sont plus maintenus par l\u0027\u00e9diteur qui incite fortement \u00e0 mettre \u00e0 jour vers la gamme Power Monitoring Expert 2021",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-22723",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22723"
},
{
"name": "CVE-2021-21869",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21869"
},
{
"name": "CVE-2021-21866",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21866"
},
{
"name": "CVE-2021-30066",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30066"
},
{
"name": "CVE-2021-30064",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30064"
},
{
"name": "CVE-2022-22724",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22724"
},
{
"name": "CVE-2019-8963",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8963"
},
{
"name": "CVE-2021-30063",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30063"
},
{
"name": "CVE-2021-30061",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30061"
},
{
"name": "CVE-2021-21863",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21863"
},
{
"name": "CVE-2022-22722",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22722"
},
{
"name": "CVE-2021-21865",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21865"
},
{
"name": "CVE-2020-7534",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7534"
},
{
"name": "CVE-2021-21867",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21867"
},
{
"name": "CVE-2022-22804",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22804"
},
{
"name": "CVE-2021-30062",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30062"
},
{
"name": "CVE-2022-22726",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22726"
},
{
"name": "CVE-2022-22725",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22725"
},
{
"name": "CVE-2021-29241",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29241"
},
{
"name": "CVE-2020-8597",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8597"
},
{
"name": "CVE-2021-29240",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29240"
},
{
"name": "CVE-2022-22727",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22727"
},
{
"name": "CVE-2021-21864",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21864"
},
{
"name": "CVE-2021-21868",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21868"
},
{
"name": "CVE-2021-30065",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30065"
},
{
"name": "CVE-2021-33485",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33485"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-017",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-01-11T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-07 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-03 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-04 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-01 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-02 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-05 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-06 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-06"
}
]
}
CVE-2022-22723
Vulnerability from csaf_se - Published: 2022-01-11 11:05 - Updated: 2022-03-02 11:05Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its Easergy P5 product line.\r\nThe Easergy P5 is a medium voltage protection relay.\r\nFailure to apply the mitigations or remediations provided below may risk disclosure of the device\r\ncredentials, denial of service, device reboot, or at attacker gaining full control of the relay. This\r\ncould result in loss of protection to your electrical network.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cybersecurity@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Easergy P5 - SEVD-2022-011-03 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03\u0026_ga=2.95494236.1781055878.1663751877-1964063624.1663165410"
},
{
"category": "self",
"summary": "Easergy P5 - SEVD-2022-011-03 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2022-011-03.json"
},
{
"category": "self",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "Easergy P5",
"tracking": {
"current_release_date": "2022-03-02T11:05:25.000Z",
"generator": {
"date": "2022-09-21T11:16:51Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.1"
}
},
"id": "SEVD-2022-011-03",
"initial_release_date": "2022-01-11T11:05:25.000Z",
"revision_history": [
{
"date": "2022-01-11T11:05:25.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2022-03-02T11:05:25.000Z",
"number": "1.1.0",
"summary": "Updated remediation instructions for clarity"
}
],
"status": "final",
"version": "1.1.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 01.401.101",
"product": {
"name": "Schneider Electric Easergy P5 \u003c 01.401.101",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Easergy P5"
},
{
"branches": [
{
"category": "product_version",
"name": "01.401.101",
"product": {
"name": "Schneider Electric Easergy P5 01.401.101",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Easergy P5"
},
{
"branches": [
{
"category": "product_version",
"name": "01.303.202",
"product": {
"name": "Schneider Electric Easergy P5 01.303.202",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Easergy P5"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Timoth\u00e9e Chauvin",
"Paul Noalhyt",
"Yuanshe Wu"
],
"organization": "Red Balloon Security"
}
],
"cve": "CVE-2022-22722",
"cwe": {
"id": "CWE-798",
"name": "Use of Hard-coded Credentials"
},
"notes": [
{
"category": "description",
"text": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could result in information\r\ndisclosure. If an attacker were to obtain the SSH cryptographic key for the device and take\r\nactive control of the local operational network connected to the product they could potentially\r\nobserve and manipulate traffic associated with product configuration.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2",
"3"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "For CVE-2022-22723 only, if customers choose not to apply the remediation provided above,\r\nthey should immediately apply the following mitigation to reduce the risk of exploit: \r\nDisable the GOOSE service of the product to reduce the risk of exposure. If GOOSE is needed\r\nfor the application use it only in a secure local area network.\r\nCustomers should use appropriate patching methodologies when applying these patches to\r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these\r\npatches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2022-22722"
},
{
"acknowledgments": [
{
"names": [
"Timoth\u00e9e Chauvin",
"Paul Noalhyt",
"Yuanshe Wu"
],
"organization": "Red Balloon Security"
}
],
"cve": "CVE-2022-22723",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "description",
"text": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a\r\nbuffer overflow causing program crashes and arbitrary code execution when specially crafted\r\npackets are sent to the device over the network. Protection functions and tripping function via\r\nGOOSE can be impacted. \r",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2",
"3"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "For CVE-2022-22723 only, if customers choose not to apply the remediation provided above,\r\nthey should immediately apply the following mitigation to reduce the risk of exploit: \r\nDisable the GOOSE service of the product to reduce the risk of exposure. If GOOSE is needed\r\nfor the application use it only in a secure local area network.\r\nCustomers should use appropriate patching methodologies when applying these patches to\r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these\r\npatches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
},
{
"category": "vendor_fix",
"details": "Versions 01.401.101 and 01.303.202 of the Easergy P5 Firmware include a fix for these\r\nvulnerabilities. The version to be used depends on the existing firmware in the Easergy P5. The\r\nfirmware packages are available on request from Schneider Electric\u2019s Customer Care Center\r\nwhich will provide the guidelines on the version to be used. ",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2022-22723"
}
]
}
ICSA-22-055-03
Vulnerability from csaf_cisa - Published: 2022-02-24 00:00 - Updated: 2022-02-24 00:00Notes
{
"document": {
"acknowledgments": [
{
"names": [
"Timoth\u00e9e Chauvin",
"Paul Noalhyt",
"Yuanzhe Wu"
],
"organization": "Red Balloon Security",
"summary": "reporting these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities may disclose device credentials, cause a denial-of-service condition, device reboot, or allow an attacker to gain full control of the relay. This could result in loss of protection to your electrical network.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities, Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-22-055-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-055-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-055-03 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-055-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric Easergy P5 and P3",
"tracking": {
"current_release_date": "2022-02-24T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-22-055-03",
"initial_release_date": "2022-02-24T00:00:00.000000Z",
"revision_history": [
{
"date": "2022-02-24T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-22-055-03 Schneider Electric Easergy P5 and P3"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 30.205",
"product": {
"name": "Easergy P3: All versions prior to v30.205",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Easergy P3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 01.401.102",
"product": {
"name": "Easergy P5 All firmware: versions prior to v01.401.102",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Easergy P5 All firmware"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-22722",
"cwe": {
"id": "CWE-798",
"name": "Use of Hard-coded Credentials"
},
"notes": [
{
"category": "summary",
"text": "If an attacker were to obtain the SSH cryptographic key for the device and take active control of the local operational network connected to this product, they could observe and manipulate traffic associated with product configuration. This could result in information disclosure. CVE-2022-22722 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-22722"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users using Easergy P5 upgrade to v01.402.101 and users using Easergy P3 upgrade to version 30.205. These firmware upgrades include a fix for the identified vulnerabilities and are available upon request from Schneider Electric\u0027s Customer Care Center.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Disable the GOOSE service of the product to reduce the risk of exposure. If GOOSE is needed for the application, use it only in a secure local area network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "For more information see Schneider Electric\u0027s security notifications: SEVD-2022-011-03, SEVD-2022-011-04",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of backups and an evaluation of the impact of these patches in a test and development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center for assistance removing a patch.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Install physical controls so no unauthorized personnel can access industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Never connect programming software to any network other than a network intended to for the devices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand VPNs are only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2022-22723",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A buffer copy without checking size of input vulnerability exists in Easergy P5 devices that could lead to a buffer overflow, causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping functions via GOOSE can be impacted. CVE-2022-22723 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-22723"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users using Easergy P5 upgrade to v01.402.101 and users using Easergy P3 upgrade to version 30.205. These firmware upgrades include a fix for the identified vulnerabilities and are available upon request from Schneider Electric\u0027s Customer Care Center.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "For CVE-2022-22723 and CVE-2022-22725 only, if users choose not to apply the remediation provided above, they should immediately apply the following mitigation to reduce the risk of exploit:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Disable the GOOSE service of the product to reduce the risk of exposure. If GOOSE is needed for the application, use it only in a secure local area network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "For more information see Schneider Electric\u0027s security notifications: SEVD-2022-011-03, SEVD-2022-011-04",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of backups and an evaluation of the impact of these patches in a test and development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center for assistance removing a patch.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Install physical controls so no unauthorized personnel can access industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Never connect programming software to any network other than a network intended to for the devices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand VPNs are only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2022-22725",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A buffer copy without checking size of input vulnerability exists in Easergy P3 devices that could lead to a buffer overflow, causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping functions via GOOSE can be impacted. CVE-2022-22725 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-22725"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users using Easergy P5 upgrade to v01.402.101 and users using Easergy P3 upgrade to version 30.205. These firmware upgrades include a fix for the identified vulnerabilities and are available upon request from Schneider Electric\u0027s Customer Care Center.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "For CVE-2022-22723 and CVE-2022-22725 only, if users choose not to apply the remediation provided above, they should immediately apply the following mitigation to reduce the risk of exploit:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Disable the GOOSE service of the product to reduce the risk of exposure. If GOOSE is needed for the application, use it only in a secure local area network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "For more information see Schneider Electric\u0027s security notifications: SEVD-2022-011-03, SEVD-2022-011-04",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of backups and an evaluation of the impact of these patches in a test and development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center for assistance removing a patch.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Install physical controls so no unauthorized personnel can access industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Never connect programming software to any network other than a network intended to for the devices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand VPNs are only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2022-34758",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An Improper Input Validation vulnerability exists in Easergy P5 devices that cause the device watchdog function to be disabled if the attacker had access to privileged user credentials. CVE-2022-34758 has been assigned to this vulnerability. A CVSS v3 base score of 5.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:L).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-34758"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:L"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users using Easergy P5 upgrade to v01.402.101 and users using Easergy P3 upgrade to version 30.205. These firmware upgrades include a fix for the identified vulnerabilities and are available upon request from Schneider Electric\u0027s Customer Care Center.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Disable the GOOSE service of the product to reduce the risk of exposure. If GOOSE is needed for the application, use it only in a secure local area network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "For more information see Schneider Electric\u0027s security notifications: SEVD-2022-011-03, SEVD-2022-011-04",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends users use appropriate patching methodologies when applying these patches to their systems. Schneider Electric recommends the use of backups and an evaluation of the impact of these patches in a test and development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center for assistance removing a patch.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/work/support/contacts.jsp"
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Install physical controls so no unauthorized personnel can access industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Never connect programming software to any network other than a network intended to for the devices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand VPNs are only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:L",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
GSD-2022-22723
Vulnerability from gsd - Updated: 2023-12-13 01:19{
"GSD": {
"alias": "CVE-2022-22723",
"description": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101)",
"id": "GSD-2022-22723"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-22723"
],
"details": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101)",
"id": "GSD-2022-22723",
"modified": "2023-12-13T01:19:29.773997Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-22723",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Easergy P5 (All firmware versions prior to V01.401.101)",
"version": {
"version_data": [
{
"version_value": "Easergy P5 (All firmware versions prior to V01.401.101)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-120: Buffer Copy without Checking Size of Input"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:easergy_p5_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "01.401.101",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:easergy_p5:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-22723"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2022-02-10T06:57Z",
"publishedDate": "2022-02-04T23:15Z"
}
}
}
FKIE_CVE-2022-22723
Vulnerability from fkie_nvd - Published: 2022-02-04 23:15 - Updated: 2024-11-21 06:47| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | easergy_p5_firmware | * | |
| schneider-electric | easergy_p5 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:easergy_p5_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5F339D52-8956-44D7-B9A3-5E33CF93F014",
"versionEndExcluding": "01.401.101",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:easergy_p5:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D642DB0E-55FF-430D-BD45-D305B13A5045",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101)"
},
{
"lang": "es",
"value": "Una CWE-120: Se presenta una vulnerabilidad de Copia del B\u00fafer sin Comprobar el Tama\u00f1o de la Entrada que podr\u00eda conllevar a un desbordamiento del b\u00fafer causando un bloqueo del programa y una ejecuci\u00f3n de c\u00f3digo arbitrario cuando son enviados paquetes especialmente dise\u00f1ados al dispositivo a trav\u00e9s de la red. Las funciones Protection y la funci\u00f3n tripping por medio de GOOSE pueden verse afectadas. Producto afectado: Easergy P5 (todas las versiones de firmware anteriores a V01.401.101)"
}
],
"id": "CVE-2022-22723",
"lastModified": "2024-11-21T06:47:19.553",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-02-04T23:15:13.113",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
GHSA-MM7J-7GQ2-X4FR
Vulnerability from github – Published: 2022-02-11 00:01 – Updated: 2022-02-11 00:01A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101)
{
"affected": [],
"aliases": [
"CVE-2022-22723"
],
"database_specific": {
"cwe_ids": [
"CWE-120"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-02-04T23:15:00Z",
"severity": "HIGH"
},
"details": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could lead to a buffer overflow causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping function via GOOSE can be impacted. Affected Product: Easergy P5 (All firmware versions prior to V01.401.101)",
"id": "GHSA-mm7j-7gq2-x4fr",
"modified": "2022-02-11T00:01:17Z",
"published": "2022-02-11T00:01:17Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-22723"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
}
],
"schema_version": "1.4.0",
"severity": []
}
CNVD-2022-70104
Vulnerability from cnvd - Published: 2022-10-21厂商尚未提供漏洞修复方案,请关注厂商主页更新: http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03
| Name | Schneider Electric Easergy P5 <01.401.101 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2022-22723",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2022-22723"
}
},
"description": "Schneider Electric Easergy P5\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u9002\u7528\u4e8e\u8981\u6c42\u82db\u523b\u7684\u4e2d\u538b\u5e94\u7528\u7684\u4fdd\u62a4\u7ee7\u7535\u5668\u3002\n\nSchneider Electric Easergy P5\u5b58\u5728\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u7684\u5b58\u5728\u662f\u7531\u4e8e\u5728\u5904\u7406\u4e0d\u53d7\u4fe1\u4efb\u7684\u8f93\u5165\u65f6\u51fa\u73b0\u8fb9\u754c\u9519\u8bef\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u7cfb\u7edf\u4e0a\u6267\u884c\u4efb\u610f\u4ee3\u7801\u3002",
"formalWay": "\u5382\u5546\u5c1a\u672a\u63d0\u4f9b\u6f0f\u6d1e\u4fee\u590d\u65b9\u6848\uff0c\u8bf7\u5173\u6ce8\u5382\u5546\u4e3b\u9875\u66f4\u65b0\uff1a\r\nhttp://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2022-70104",
"openTime": "2022-10-21",
"products": {
"product": "Schneider Electric Easergy P5 \u003c01.401.101"
},
"referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2022-22723",
"serverity": "\u9ad8",
"submitTime": "2022-01-16",
"title": "Schneider Electric Easergy P5\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.