Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2021-22799 (GCVE-0-2021-22799)
Vulnerability from cvelistv5 – Published: 2022-01-28 19:09 – Updated: 2024-08-03 18:51- n/a
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.475Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-28T19:09:41",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22799",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22799",
"datePublished": "2022-01-28T19:09:42",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.475Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:software_update:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2.3.0\", \"versionEndExcluding\": \"2.5.2\", \"matchCriteriaId\": \"BCC1E042-7930-4E73-A79D-51B7A7777CBA\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1\"}, {\"lang\": \"es\", \"value\": \"Una CWE-331: Se presenta una vulnerabilidad de Entrop\\u00eda Insuficiente que podr\\u00eda causar una conexi\\u00f3n no intencionada desde una red interna a una red externa cuando un atacante consigue descifrar la contrase\\u00f1a del proxy SESU desde el registro. Producto afectado: Schneider Electric Software Update, V2.3.0 hasta V2.5.1\"}]",
"id": "CVE-2021-22799",
"lastModified": "2024-11-21T05:50:41.650",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N\", \"baseScore\": 3.8, \"baseSeverity\": \"LOW\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.0, \"impactScore\": 1.4}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:P/I:N/A:N\", \"baseScore\": 2.1, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 3.9, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2022-01-28T20:15:09.770",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-331\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-22799\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2022-01-28T20:15:09.770\",\"lastModified\":\"2024-11-21T05:50:41.650\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1\"},{\"lang\":\"es\",\"value\":\"Una CWE-331: Se presenta una vulnerabilidad de Entrop\u00eda Insuficiente que podr\u00eda causar una conexi\u00f3n no intencionada desde una red interna a una red externa cuando un atacante consigue descifrar la contrase\u00f1a del proxy SESU desde el registro. Producto afectado: Schneider Electric Software Update, V2.3.0 hasta V2.5.1\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N\",\"baseScore\":3.8,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.0,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":2.1,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-331\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:software_update:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.3.0\",\"versionEndExcluding\":\"2.5.2\",\"matchCriteriaId\":\"BCC1E042-7930-4E73-A79D-51B7A7777CBA\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
}
}
GHSA-H572-23QR-5763
Vulnerability from github – Published: 2022-01-29 00:00 – Updated: 2022-02-04 00:00A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1
{
"affected": [],
"aliases": [
"CVE-2021-22799"
],
"database_specific": {
"cwe_ids": [
"CWE-331"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-01-28T20:15:00Z",
"severity": "LOW"
},
"details": "A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1",
"id": "GHSA-h572-23qr-5763",
"modified": "2022-02-04T00:00:45Z",
"published": "2022-01-29T00:00:46Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-22799"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02"
}
],
"schema_version": "1.4.0",
"severity": []
}
CERTFR-2021-AVI-853
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | Momentum MDI (171CBU*), MC80 (BMKC8*), HART (BMEAH*) toutes versions | ||
| N/A | N/A | versadac, toutes versions | ||
| Schneider Electric | N/A | EPack toutes versions | ||
| N/A | N/A | EPC2000 toutes versions | ||
| N/A | N/A | Modicon M262 Logic Controllers firmware version 5.1.5.35 et antérieures | ||
| N/A | N/A | SCD6000 Industrial RTU Version antérieures à SCD6000 is SY-1101211_Mand | ||
| N/A | N/A | SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E et 357E RTUs avec le firmware V8.18.1 et antérieures | ||
| N/A | N/A | NMC embedded devices | ||
| N/A | N/A | BMENOC0321, BMENOC0301, BMENOC0311, BMENOS0300 toutes versions | ||
| N/A | N/A | BMECRA31210, BMXCRA31200, BMXCRA31210, 140CRA31200, 140CRA31908 toutes versions | ||
| Schneider Electric | N/A | Modicon M241/M251 Logic Controllers firmware version 5.1.9.21 et antérieures | ||
| Symfony | process | EcoStruxure Process Expert versions antérieures à V2021 | ||
| N/A | N/A | Tricon Communication Modules versions antérieures à 11.8 | ||
| N/A | N/A | TelevisAir V3.0 Dongle BTLE (part number ADBT42* et antérieures) | ||
| Schneider Electric | Modicon M340 | Modicon M580 CPU (BMEP* and BMEH*), Modicon M340 CPU (BMXP34*), BMXNOM0200 toutes versions | ||
| Schneider Electric | N/A | Easy Harmony GXU (HMIGXU Series) et Easy Harmony ET6 (HMIET Series) Vijeo Designer Basic V1.2 family et antérieures | ||
| Schneider Electric | N/A | T2750 PAC, toutes versions | ||
| Schneider Electric | N/A | Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) et antérieures | ||
| N/A | N/A | HMISTO Series HMISTU/S5T Series toutes versions | ||
| Schneider Electric | N/A | TCSEGPA23F14F, BMECXM0100 toutes versions | ||
| N/A | N/A | HMISCU,HMIGTU, HMIG2U, HMIG3U, HMIG3X, HMIGTO Series Vijeo Designer (V6.2 SP11) family et antérieures | ||
| N/A | N/A | BMXNOE0100, BMXNOE0110, BMXNGD0100, BMXNOC0401 toutes versions | ||
| N/A | N/A | Pro-face GP4100 Series, GP4000E Series, GP4000M Series toutes versions | ||
| N/A | N/A | Pro-face SP-5B00, SP-5B10, SP-5B90, ST6000 Series (GP-ProEX model), ET6000 Series GP-Pro EX V4.09.300 et antérieures | ||
| N/A | N/A | Momentum ENT (170ENT11*) toutes versions | ||
| Schneider Electric | N/A | nanodac toutes versions | ||
| Schneider Electric | N/A | Network Management Card 2 (NMC2) | ||
| Schneider Electric | N/A | Schneider Electric Software Update, V2.3.0 à V2.5.1 | ||
| N/A | N/A | Network Management Card 3 (NMC3) | ||
| N/A | N/A | 6100A, 6180A, 6100XIO, 6180XIO, AeroDAQ toutes versions | ||
| Schneider Electric | N/A | BMXNOM0200 toutes versions | ||
| N/A | N/A | BMENOP0300, BMXNOR0200 toutes versions | ||
| Schneider Electric | N/A | Modicon LMC078 toutes versions | ||
| Schneider Electric | N/A | E+PLC400 toutes versions | ||
| N/A | N/A | Pro-face GP4000 Series, LT4000M Series, GP4000H Series GP-Pro EX V4.09.300 et antérieures |
| Title | Publication Time | Tags | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Momentum MDI (171CBU*), MC80 (BMKC8*), HART (BMEAH*) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "versadac, toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EPack toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EPC2000 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon M262 Logic Controllers firmware version 5.1.5.35 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "SCD6000 Industrial RTU Version ant\u00e9rieures \u00e0 SCD6000 is SY-1101211_Mand",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E et 357E RTUs avec le firmware V8.18.1 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "NMC embedded devices",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "BMENOC0321, BMENOC0301, BMENOC0311, BMENOS0300 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "BMECRA31210, BMXCRA31200, BMXCRA31210, 140CRA31200, 140CRA31908 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon M241/M251 Logic Controllers firmware version 5.1.9.21 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Process Expert versions ant\u00e9rieures \u00e0 V2021",
"product": {
"name": "process",
"vendor": {
"name": "Symfony",
"scada": false
}
}
},
{
"description": "Tricon Communication Modules versions ant\u00e9rieures \u00e0 11.8",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "TelevisAir V3.0 Dongle BTLE (part number ADBT42* et ant\u00e9rieures)",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon M580 CPU (BMEP* and BMEH*), Modicon M340 CPU (BMXP34*), BMXNOM0200 toutes versions",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easy Harmony GXU (HMIGXU Series) et Easy Harmony ET6 (HMIET Series) Vijeo Designer Basic V1.2 family et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "T2750 PAC, toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "HMISTO Series HMISTU/S5T Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "TCSEGPA23F14F, BMECXM0100 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "HMISCU,HMIGTU, HMIG2U, HMIG3U, HMIG3X, HMIGTO Series Vijeo Designer (V6.2 SP11) family et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "BMXNOE0100, BMXNOE0110, BMXNGD0100, BMXNOC0401 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Pro-face GP4100 Series, GP4000E Series, GP4000M Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Pro-face SP-5B00, SP-5B10, SP-5B90, ST6000 Series (GP-ProEX model), ET6000 Series GP-Pro EX V4.09.300 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Momentum ENT (170ENT11*) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "nanodac toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network Management Card 2 (NMC2)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Software Update, V2.3.0 \u00e0 V2.5.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network Management Card 3 (NMC3)",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "6100A, 6180A, 6100XIO, 6180XIO, AeroDAQ toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "BMXNOM0200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMENOP0300, BMXNOR0200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon LMC078 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "E+PLC400 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face GP4000 Series, LT4000M Series, GP4000H Series GP-Pro EX V4.09.300 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-22808",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22808"
},
{
"name": "CVE-2021-34527",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-34527"
},
{
"name": "CVE-2021-22811",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22811"
},
{
"name": "CVE-2021-22813",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22813"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2021-22807",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22807"
},
{
"name": "CVE-2021-22810",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22810"
},
{
"name": "CVE-2021-22815",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22815"
},
{
"name": "CVE-2021-1675",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-1675"
},
{
"name": "CVE-2021-22812",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22812"
},
{
"name": "CVE-2021-22809",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22809"
},
{
"name": "CVE-2021-22814",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22814"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2021-22799",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22799"
},
{
"name": "CVE-2021-22816",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22816"
}
],
"links": [],
"reference": "CERTFR-2021-AVI-853",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-11-09T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-07 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-01 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-06 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-06"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-04 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-02 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-03 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03"
}
]
}
CERTFR-2021-AVI-853
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | Momentum MDI (171CBU*), MC80 (BMKC8*), HART (BMEAH*) toutes versions | ||
| N/A | N/A | versadac, toutes versions | ||
| Schneider Electric | N/A | EPack toutes versions | ||
| N/A | N/A | EPC2000 toutes versions | ||
| N/A | N/A | Modicon M262 Logic Controllers firmware version 5.1.5.35 et antérieures | ||
| N/A | N/A | SCD6000 Industrial RTU Version antérieures à SCD6000 is SY-1101211_Mand | ||
| N/A | N/A | SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E et 357E RTUs avec le firmware V8.18.1 et antérieures | ||
| N/A | N/A | NMC embedded devices | ||
| N/A | N/A | BMENOC0321, BMENOC0301, BMENOC0311, BMENOS0300 toutes versions | ||
| N/A | N/A | BMECRA31210, BMXCRA31200, BMXCRA31210, 140CRA31200, 140CRA31908 toutes versions | ||
| Schneider Electric | N/A | Modicon M241/M251 Logic Controllers firmware version 5.1.9.21 et antérieures | ||
| Symfony | process | EcoStruxure Process Expert versions antérieures à V2021 | ||
| N/A | N/A | Tricon Communication Modules versions antérieures à 11.8 | ||
| N/A | N/A | TelevisAir V3.0 Dongle BTLE (part number ADBT42* et antérieures) | ||
| Schneider Electric | Modicon M340 | Modicon M580 CPU (BMEP* and BMEH*), Modicon M340 CPU (BMXP34*), BMXNOM0200 toutes versions | ||
| Schneider Electric | N/A | Easy Harmony GXU (HMIGXU Series) et Easy Harmony ET6 (HMIET Series) Vijeo Designer Basic V1.2 family et antérieures | ||
| Schneider Electric | N/A | T2750 PAC, toutes versions | ||
| Schneider Electric | N/A | Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) et antérieures | ||
| N/A | N/A | HMISTO Series HMISTU/S5T Series toutes versions | ||
| Schneider Electric | N/A | TCSEGPA23F14F, BMECXM0100 toutes versions | ||
| N/A | N/A | HMISCU,HMIGTU, HMIG2U, HMIG3U, HMIG3X, HMIGTO Series Vijeo Designer (V6.2 SP11) family et antérieures | ||
| N/A | N/A | BMXNOE0100, BMXNOE0110, BMXNGD0100, BMXNOC0401 toutes versions | ||
| N/A | N/A | Pro-face GP4100 Series, GP4000E Series, GP4000M Series toutes versions | ||
| N/A | N/A | Pro-face SP-5B00, SP-5B10, SP-5B90, ST6000 Series (GP-ProEX model), ET6000 Series GP-Pro EX V4.09.300 et antérieures | ||
| N/A | N/A | Momentum ENT (170ENT11*) toutes versions | ||
| Schneider Electric | N/A | nanodac toutes versions | ||
| Schneider Electric | N/A | Network Management Card 2 (NMC2) | ||
| Schneider Electric | N/A | Schneider Electric Software Update, V2.3.0 à V2.5.1 | ||
| N/A | N/A | Network Management Card 3 (NMC3) | ||
| N/A | N/A | 6100A, 6180A, 6100XIO, 6180XIO, AeroDAQ toutes versions | ||
| Schneider Electric | N/A | BMXNOM0200 toutes versions | ||
| N/A | N/A | BMENOP0300, BMXNOR0200 toutes versions | ||
| Schneider Electric | N/A | Modicon LMC078 toutes versions | ||
| Schneider Electric | N/A | E+PLC400 toutes versions | ||
| N/A | N/A | Pro-face GP4000 Series, LT4000M Series, GP4000H Series GP-Pro EX V4.09.300 et antérieures |
| Title | Publication Time | Tags | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Momentum MDI (171CBU*), MC80 (BMKC8*), HART (BMEAH*) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "versadac, toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EPack toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EPC2000 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon M262 Logic Controllers firmware version 5.1.5.35 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "SCD6000 Industrial RTU Version ant\u00e9rieures \u00e0 SCD6000 is SY-1101211_Mand",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E et 357E RTUs avec le firmware V8.18.1 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "NMC embedded devices",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "BMENOC0321, BMENOC0301, BMENOC0311, BMENOS0300 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "BMECRA31210, BMXCRA31200, BMXCRA31210, 140CRA31200, 140CRA31908 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon M241/M251 Logic Controllers firmware version 5.1.9.21 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Process Expert versions ant\u00e9rieures \u00e0 V2021",
"product": {
"name": "process",
"vendor": {
"name": "Symfony",
"scada": false
}
}
},
{
"description": "Tricon Communication Modules versions ant\u00e9rieures \u00e0 11.8",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "TelevisAir V3.0 Dongle BTLE (part number ADBT42* et ant\u00e9rieures)",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon M580 CPU (BMEP* and BMEH*), Modicon M340 CPU (BMXP34*), BMXNOM0200 toutes versions",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easy Harmony GXU (HMIGXU Series) et Easy Harmony ET6 (HMIET Series) Vijeo Designer Basic V1.2 family et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "T2750 PAC, toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "HMISTO Series HMISTU/S5T Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "TCSEGPA23F14F, BMECXM0100 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "HMISCU,HMIGTU, HMIG2U, HMIG3U, HMIG3X, HMIGTO Series Vijeo Designer (V6.2 SP11) family et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "BMXNOE0100, BMXNOE0110, BMXNGD0100, BMXNOC0401 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Pro-face GP4100 Series, GP4000E Series, GP4000M Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Pro-face SP-5B00, SP-5B10, SP-5B90, ST6000 Series (GP-ProEX model), ET6000 Series GP-Pro EX V4.09.300 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Momentum ENT (170ENT11*) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "nanodac toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network Management Card 2 (NMC2)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Software Update, V2.3.0 \u00e0 V2.5.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Network Management Card 3 (NMC3)",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "6100A, 6180A, 6100XIO, 6180XIO, AeroDAQ toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "BMXNOM0200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMENOP0300, BMXNOR0200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon LMC078 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "E+PLC400 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face GP4000 Series, LT4000M Series, GP4000H Series GP-Pro EX V4.09.300 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-22808",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22808"
},
{
"name": "CVE-2021-34527",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-34527"
},
{
"name": "CVE-2021-22811",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22811"
},
{
"name": "CVE-2021-22813",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22813"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2021-22807",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22807"
},
{
"name": "CVE-2021-22810",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22810"
},
{
"name": "CVE-2021-22815",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22815"
},
{
"name": "CVE-2021-1675",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-1675"
},
{
"name": "CVE-2021-22812",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22812"
},
{
"name": "CVE-2021-22809",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22809"
},
{
"name": "CVE-2021-22814",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22814"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2021-22799",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22799"
},
{
"name": "CVE-2021-22816",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22816"
}
],
"links": [],
"reference": "CERTFR-2021-AVI-853",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-11-09T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-07 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-01 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-06 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-06"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-04 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-02 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-03 du 9 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03"
}
]
}
FKIE_CVE-2021-22799
Vulnerability from fkie_nvd - Published: 2022-01-28 20:15 - Updated: 2024-11-21 05:50| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02 | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02 | Patch, Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | software_update | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:software_update:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BCC1E042-7930-4E73-A79D-51B7A7777CBA",
"versionEndExcluding": "2.5.2",
"versionStartIncluding": "2.3.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1"
},
{
"lang": "es",
"value": "Una CWE-331: Se presenta una vulnerabilidad de Entrop\u00eda Insuficiente que podr\u00eda causar una conexi\u00f3n no intencionada desde una red interna a una red externa cuando un atacante consigue descifrar la contrase\u00f1a del proxy SESU desde el registro. Producto afectado: Schneider Electric Software Update, V2.3.0 hasta V2.5.1"
}
],
"id": "CVE-2021-22799",
"lastModified": "2024-11-21T05:50:41.650",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.0,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-01-28T20:15:09.770",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-331"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2021-22799
Vulnerability from csaf_se - Published: 2021-11-09 00:00 - Updated: 2021-11-09 00:00Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in its Schneider Electric Software Update product (also referred to as \u201cSESU\u201d), which is used to notify and download updates for other Schneider Electric Software products.\r\nTo connect to the Internet, the SESU product offers users to manually configure the proxy settings. Due to an improper protection of the saved credentials, it is potentially possible for an attacker to decrypt these credentials.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Schneider Electric Software Update - SEVD-2021-313-02 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-02_SESU_Security_Notification.pdf"
},
{
"category": "self",
"summary": "Schneider Electric Software Update - SEVD-2021-313-02 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2021-313-02.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "Schneider Electric Software Update",
"tracking": {
"current_release_date": "2021-11-09T00:00:00.000Z",
"generator": {
"date": "2021-11-09T00:00:00.000Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2021-313-02",
"initial_release_date": "2021-11-09T00:00:00.000Z",
"revision_history": [
{
"date": "2021-11-09T00:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=2.3.0|\u003c=2.5.1",
"product": {
"name": "Schneider Electric Schneider Electric Software Update, V2.3.0 through V2.5.1",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"EcoStruxure Augmented Operator Advisor",
"EcoStruxure Control Expert (formerly known as Unity Pro)",
"EcoStruxure Process Expert (formerly known as EcoStruxure Hybrid Distributed Control System)",
"EcoStruxure Machine Expert (formerly known as SoMachine or SoMachine Motion)",
"EcoStruxure Machine Expert Basic",
"EcoStruxure Operator Terminal Expert",
"EcoStruxure Plant Builder",
"EcoStruxure Power Design",
"EcoStruxure Automation Expert",
"EcoStruxure Automation Maintenance Expert",
"Eurotherm Data Reviewer",
"Eurotherm iTools",
"eXLhoist Configuration Software",
"Schneider Electric Floating License Manager",
"Schneider Electric License Manager",
"Harmony XB5SSoft",
"SoMove",
"Versatile Software BLUE",
"Vijeo Designer",
"OsiSense XX Configuration Software",
"Zelio Soft 2"
]
}
}
}
],
"category": "product_name",
"name": "Schneider Electric Software Update,"
},
{
"branches": [
{
"category": "product_version",
"name": "2.5.2",
"product": {
"name": "Schneider Electric Schneider Electric Software Update, 2.5.2",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Schneider Electric Software Update,"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"organization": "Nozomi Networks via ICS-CERT/CISA"
}
],
"cve": "CVE-2021-22799",
"cwe": {
"id": "CWE-331",
"name": "Insufficient Entropy"
},
"notes": [
{
"category": "description",
"text": "A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "The version V2.5.2 of the SESU product includes a fix for this vulnerability and is available for download here:\r\nhttps://www.seupdate.schneider-electric.com/download/SystemConsistency/SoftwareUpdate/SESU_latest_version/SESU_latest_setup_sfx.exe\r\nNote: This link will always be updated to point to the latest version of SESU\r\nIf you have already installed SESU and activated notification of updates, it will show that a new security patch is available for installation. To install the security update, which is strongly recommended, download and execute the setup file. However, as long as versions 2.3.0 - 2.5.1 of SESU are installed and configured to use a manually defined proxy server with credentials, make sure only authorized users, which are allowed to see them, have access to this machine. If this cannot be guaranteed, make sure no proxy credentials are stored.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.seupdate.schneider-electric.com/download/SystemConsistency/SoftwareUpdate/SESU_latest_version/SESU_latest_setup_sfx.exe"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2021-22799"
}
]
}
GSD-2021-22799
Vulnerability from gsd - Updated: 2023-12-13 01:23{
"GSD": {
"alias": "CVE-2021-22799",
"description": "A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1",
"id": "GSD-2021-22799"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-22799"
],
"details": "A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1",
"id": "GSD-2021-22799",
"modified": "2023-12-13T01:23:24.905693Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22799",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:software_update:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.5.2",
"versionStartIncluding": "2.3.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22799"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-331"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02",
"refsource": "MISC",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "LOW",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.0,
"impactScore": 1.4
}
},
"lastModifiedDate": "2022-02-03T14:59Z",
"publishedDate": "2022-01-28T20:15Z"
}
}
}
ICSA-21-336-01
Vulnerability from csaf_cisa - Published: 2021-12-02 00:00 - Updated: 2021-12-02 00:00Notes
{
"document": {
"acknowledgments": [
{
"organization": "Nozomi Networks",
"summary": "reporting this vulnerability to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could cause unintended connection from an internal network to an external network.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities, Critical Manufacturing, Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-21-336-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-336-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-336-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-336-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric SESU",
"tracking": {
"current_release_date": "2021-12-02T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-336-01",
"initial_release_date": "2021-12-02T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-12-02T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-21-336-01 Schneider Electric SESU"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= 2.3.0 | \u003c= 2.5.1",
"product": {
"name": "Schneider Electric Software Update: v2.3.0 through v2.5.1",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Schneider Electric Software Update"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-22799",
"cwe": {
"id": "CWE-331",
"name": "Insufficient Entropy"
},
"notes": [
{
"category": "summary",
"text": "An insufficient entropy vulnerability exists, which could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry.CVE-2021-22799 has been assigned to this vulnerability. A CVSS v3 base score of 3.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22799"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "If SESU is installed (assuming SESU is configured as \u201cmanaged product\u201d inside the SESU application) it will indicate a security update is available. Click to download and install the new SESU version.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "If SESU is not installed, download SESU (automatic download) and follow the installation instructions.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.seupdate.schneider-electric.com/download/SystemConsistency/SoftwareUpdate/SESU_latest_version/SESU_latest_setup_sfx.exe"
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Never connect programming software to any network other than the network intended for that device.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN are only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "See Schneider Electric Security Notification SEVD-2021-313-02 for more information.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.8,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.