CVE-2021-22697 (GCVE-0-2021-22697)
Vulnerability from cvelistv5 – Published: 2021-01-25 17:09 – Updated: 2024-08-03 18:51- CWE-434 - Unrestricted Upload of File with Dangerous Type
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | EcoStruxure Power Build - Rapsody software V2.1.13 and prior. |
Affected:
EcoStruxure Power Build - Rapsody software V2.1.13 and prior.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.429Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "\u00a0EcoStruxure Power Build - Rapsody software V2.1.13 and prior.\u00a0",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "EcoStruxure Power Build - Rapsody software V2.1.13 and prior."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434: Unrestricted Upload of File with Dangerous Type",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-18T17:58:40",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22697",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "\u00a0EcoStruxure Power Build - Rapsody software V2.1.13 and prior.\u00a0",
"version": {
"version_data": [
{
"version_value": "EcoStruxure Power Build - Rapsody software V2.1.13 and prior."
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-434: Unrestricted Upload of File with Dangerous Type"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22697",
"datePublished": "2021-01-25T17:09:26",
"dateReserved": "2021-01-06T00:00:00",
"dateUpdated": "2024-08-03T18:51:07.429Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"2.1.13\", \"matchCriteriaId\": \"E458DE1E-6488-4F4A-BD96-7E46DA716BC5\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.\"}, {\"lang\": \"es\", \"value\": \"CWE-434: Se presenta una vulnerabilidad de Carga Sin Restricciones de Archivo con Tipo Peligroso en el software EcoStruxure Power Build - Rapsody (versiones V2.1.13 y anteriores) que podr\\u00eda permitir una condici\\u00f3n de uso de la memoria previamente liberada que podr\\u00eda resultar en una ejecuci\\u00f3n de c\\u00f3digo remota cuando un archivo SSD malicioso es cargado y analizado inapropiadamente\"}]",
"id": "CVE-2021-22697",
"lastModified": "2024-11-21T05:50:29.000",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2021-01-26T18:16:18.867",
"references": "[{\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2021-012-02/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-21-186/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2021-012-02/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-21-186/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-434\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-22697\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2021-01-26T18:16:18.867\",\"lastModified\":\"2024-11-21T05:50:29.000\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.\"},{\"lang\":\"es\",\"value\":\"CWE-434: Se presenta una vulnerabilidad de Carga Sin Restricciones de Archivo con Tipo Peligroso en el software EcoStruxure Power Build - Rapsody (versiones V2.1.13 y anteriores) que podr\u00eda permitir una condici\u00f3n de uso de la memoria previamente liberada que podr\u00eda resultar en una ejecuci\u00f3n de c\u00f3digo remota cuando un archivo SSD malicioso es cargado y analizado inapropiadamente\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-434\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.1.13\",\"matchCriteriaId\":\"E458DE1E-6488-4F4A-BD96-7E46DA716BC5\"}]}]}],\"references\":[{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2021-012-02/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-186/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2021-012-02/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-186/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}"
}
}
CERTFR-2021-AVI-024
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance et un déni de service à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | EcoStruxure Operator Terminal Expert versions antérieures à V3.1 Service Pack 1B | ||
| Schneider Electric | N/A | Le serveur HTTP Treck de Sepam ACE850 | ||
| Schneider Electric | N/A | EcoStruxure Power Build - Rapsody versions 2.1.13 et antérieures | ||
| Schneider Electric | N/A | Pro-face BLUE versions antérieures à V3.1 Service Pack 1B |
| Title | Publication Time | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "EcoStruxure Operator Terminal Expert versions ant\u00e9rieures \u00e0 V3.1 Service Pack 1B",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Le serveur HTTP Treck de Sepam ACE850",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build - Rapsody versions 2.1.13 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face BLUE versions ant\u00e9rieures \u00e0 V3.1 Service Pack 1B",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-28221",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28221"
},
{
"name": "CVE-2020-25066",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25066"
},
{
"name": "CVE-2021-22697",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22697"
},
{
"name": "CVE-2021-22698",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22698"
}
],
"links": [],
"reference": "CERTFR-2021-AVI-024",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-01-13T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Elles permettent \u00e0 un attaquant de provoquer une\nex\u00e9cution de code arbitraire \u00e0 distance et un d\u00e9ni de service \u00e0\ndistance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-012-01 du 12 janvier 2021",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-01/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-012-02 du 12 janvier 2021",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-012-03 du 12 janvier 2021",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-03/"
}
]
}
CERTFR-2021-AVI-024
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance et un déni de service à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | EcoStruxure Operator Terminal Expert versions antérieures à V3.1 Service Pack 1B | ||
| Schneider Electric | N/A | Le serveur HTTP Treck de Sepam ACE850 | ||
| Schneider Electric | N/A | EcoStruxure Power Build - Rapsody versions 2.1.13 et antérieures | ||
| Schneider Electric | N/A | Pro-face BLUE versions antérieures à V3.1 Service Pack 1B |
| Title | Publication Time | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "EcoStruxure Operator Terminal Expert versions ant\u00e9rieures \u00e0 V3.1 Service Pack 1B",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Le serveur HTTP Treck de Sepam ACE850",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build - Rapsody versions 2.1.13 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Pro-face BLUE versions ant\u00e9rieures \u00e0 V3.1 Service Pack 1B",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-28221",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28221"
},
{
"name": "CVE-2020-25066",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25066"
},
{
"name": "CVE-2021-22697",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22697"
},
{
"name": "CVE-2021-22698",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22698"
}
],
"links": [],
"reference": "CERTFR-2021-AVI-024",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-01-13T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Elles permettent \u00e0 un attaquant de provoquer une\nex\u00e9cution de code arbitraire \u00e0 distance et un d\u00e9ni de service \u00e0\ndistance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-012-01 du 12 janvier 2021",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-01/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-012-02 du 12 janvier 2021",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2021-012-03 du 12 janvier 2021",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-03/"
}
]
}
CERTFR-2022-AVI-546
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Conext ComBox toutes versions | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | CanBRASS versions antérieures à 7.6 | ||
| Schneider Electric | N/A | StruxureWare Data Center Expert versions antérieures à 7.9.1 | ||
| N/A | N/A | EcoStruxure Power Commission versions antérieures à 2.22 | ||
| Schneider Electric | N/A | Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Cybersecurity Admin Expert (CAE) versions antérieures à 2.4 | ||
| Schneider Electric | N/A | IGSS Data Server versions antérieures à 15.0.0.22170 | ||
| Schneider Electric | N/A | Geo SCADA Mobile versions antérieures au Build 202205171 | ||
| Schneider Electric | N/A | Smart-UPS SRT Series versions antérieures à 15.0 | ||
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | EcoStruxure Power Build: Rapsody Software versions antérieures à 2.1.13 | ||
| Schneider Electric | N/A | EPC2000 versions antérieures à 4.03 | ||
| Schneider Electric | N/A | Versadac versions antérieures à 2.43 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | SCADAPack RemoteConnect pour x70 versions antérieures à R2.7.3 | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500AC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Smart-UPS SCL Series versions antérieures à 15.1 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Conext ComBox toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "CanBRASS versions ant\u00e9rieures \u00e0 7.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "StruxureWare Data Center Expert versions ant\u00e9rieures \u00e0 7.9.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Commission versions ant\u00e9rieures \u00e0 2.22",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Cybersecurity Admin Expert (CAE) versions ant\u00e9rieures \u00e0 2.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Data Server versions ant\u00e9rieures \u00e0 15.0.0.22170",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Geo SCADA Mobile versions ant\u00e9rieures au Build 202205171",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SRT Series versions ant\u00e9rieures \u00e0 15.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build: Rapsody Software versions ant\u00e9rieures \u00e0 2.1.13",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EPC2000 versions ant\u00e9rieures \u00e0 4.03",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Versadac versions ant\u00e9rieures \u00e0 2.43",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SCADAPack RemoteConnect pour x70 versions ant\u00e9rieures \u00e0 R2.7.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500AC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SCL Series versions ant\u00e9rieures \u00e0 15.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-32524",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32524"
},
{
"name": "CVE-2022-24322",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24322"
},
{
"name": "CVE-2022-22731",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22731"
},
{
"name": "CVE-2022-32514",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32514"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-32517",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32517"
},
{
"name": "CVE-2022-32526",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32526"
},
{
"name": "CVE-2022-32530",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32530"
},
{
"name": "CVE-2022-32748",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32748"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2022-32529",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32529"
},
{
"name": "CVE-2022-32513",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32513"
},
{
"name": "CVE-2022-32747",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32747"
},
{
"name": "CVE-2022-32523",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32523"
},
{
"name": "CVE-2022-32528",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32528"
},
{
"name": "CVE-2022-32516",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32516"
},
{
"name": "CVE-2022-32522",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32522"
},
{
"name": "CVE-2022-32527",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32527"
},
{
"name": "CVE-2022-32515",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32515"
},
{
"name": "CVE-2021-22697",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22697"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2022-0223",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0223"
},
{
"name": "CVE-2022-32519",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32519"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2022-24323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24323"
},
{
"name": "CVE-2022-32512",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32512"
},
{
"name": "CVE-2022-32518",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32518"
},
{
"name": "CVE-2022-22732",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22732"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2022-32520",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32520"
},
{
"name": "CVE-2022-32525",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32525"
},
{
"name": "CVE-2021-22698",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22698"
},
{
"name": "CVE-2022-32521",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32521"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-546",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-06-15T00:00:00.000000"
},
{
"description": "Modification de la version des produits IGSS Data Server",
"revision_date": "2022-06-23T00:00:00.000000"
},
{
"description": "Mise \u00e0 jour du lien du bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022.",
"revision_date": "2022-08-19T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-02_APC-Smart-UPS_Security_Notification_V6.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-07 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-07_CanBRASS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-06 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-01 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-01_EcoStruxure_Control_Expert_and_EcoStruxure_Process_Expert_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-02 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-08 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-012-02 du 12 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-012-02_EcoStruxure_Power_Build_Rapsody_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-04 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_%20StruxureWare_Data_Center_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-01 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-05 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_Badalloc_Vulnerabilities_Security_Notification_V8.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-03 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
]
}
CERTFR-2022-AVI-546
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500SHAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Conext ComBox toutes versions | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | CanBRASS versions antérieures à 7.6 | ||
| Schneider Electric | N/A | StruxureWare Data Center Expert versions antérieures à 7.9.1 | ||
| N/A | N/A | EcoStruxure Power Commission versions antérieures à 2.22 | ||
| Schneider Electric | N/A | Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Cybersecurity Admin Expert (CAE) versions antérieures à 2.4 | ||
| Schneider Electric | N/A | IGSS Data Server versions antérieures à 15.0.0.22170 | ||
| Schneider Electric | N/A | Geo SCADA Mobile versions antérieures au Build 202205171 | ||
| Schneider Electric | N/A | Smart-UPS SRT Series versions antérieures à 15.0 | ||
| Schneider Electric | N/A | Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | EcoStruxure Power Build: Rapsody Software versions antérieures à 2.1.13 | ||
| Schneider Electric | N/A | EPC2000 versions antérieures à 4.03 | ||
| Schneider Electric | N/A | Versadac versions antérieures à 2.43 | ||
| Schneider Electric | N/A | Clipsal C-Bus Network Automation Controller 5500NAC versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | SCADAPack RemoteConnect pour x70 versions antérieures à R2.7.3 | ||
| Schneider Electric | N/A | SpaceLogic C-Bus Network Automation Controller 5500AC2 versions antérieures à 1.11.0 | ||
| Schneider Electric | N/A | Smart-UPS SCL Series versions antérieures à 15.1 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500SHAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Conext ComBox toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500NAC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "CanBRASS versions ant\u00e9rieures \u00e0 7.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "StruxureWare Data Center Expert versions ant\u00e9rieures \u00e0 7.9.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Commission versions ant\u00e9rieures \u00e0 2.22",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Smart-UPS SMT SMC, SMX, SRC, XU, XP, SURTD, CHS2 et SRTL Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Cybersecurity Admin Expert (CAE) versions ant\u00e9rieures \u00e0 2.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Data Server versions ant\u00e9rieures \u00e0 15.0.0.22170",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Geo SCADA Mobile versions ant\u00e9rieures au Build 202205171",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SRT Series versions ant\u00e9rieures \u00e0 15.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric C-Bus Network Automation Controller LSS5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Build: Rapsody Software versions ant\u00e9rieures \u00e0 2.1.13",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EPC2000 versions ant\u00e9rieures \u00e0 4.03",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Versadac versions ant\u00e9rieures \u00e0 2.43",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Clipsal C-Bus Network Automation Controller 5500NAC versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SCADAPack RemoteConnect pour x70 versions ant\u00e9rieures \u00e0 R2.7.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "SpaceLogic C-Bus Network Automation Controller 5500AC2 versions ant\u00e9rieures \u00e0 1.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Smart-UPS SCL Series versions ant\u00e9rieures \u00e0 15.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-32524",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32524"
},
{
"name": "CVE-2022-24322",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24322"
},
{
"name": "CVE-2022-22731",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22731"
},
{
"name": "CVE-2022-32514",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32514"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-32517",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32517"
},
{
"name": "CVE-2022-32526",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32526"
},
{
"name": "CVE-2022-32530",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32530"
},
{
"name": "CVE-2022-32748",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32748"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2022-32529",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32529"
},
{
"name": "CVE-2022-32513",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32513"
},
{
"name": "CVE-2022-32747",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32747"
},
{
"name": "CVE-2022-32523",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32523"
},
{
"name": "CVE-2022-32528",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32528"
},
{
"name": "CVE-2022-32516",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32516"
},
{
"name": "CVE-2022-32522",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32522"
},
{
"name": "CVE-2022-32527",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32527"
},
{
"name": "CVE-2022-32515",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32515"
},
{
"name": "CVE-2021-22697",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22697"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2022-0223",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0223"
},
{
"name": "CVE-2022-32519",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32519"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2022-24323",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24323"
},
{
"name": "CVE-2022-32512",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32512"
},
{
"name": "CVE-2022-32518",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32518"
},
{
"name": "CVE-2022-22732",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22732"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2022-32520",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32520"
},
{
"name": "CVE-2022-32525",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32525"
},
{
"name": "CVE-2021-22698",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22698"
},
{
"name": "CVE-2022-32521",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32521"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-546",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-06-15T00:00:00.000000"
},
{
"description": "Modification de la version des produits IGSS Data Server",
"revision_date": "2022-06-23T00:00:00.000000"
},
{
"description": "Mise \u00e0 jour du lien du bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022.",
"revision_date": "2022-08-19T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-02_APC-Smart-UPS_Security_Notification_V6.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-07 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-07_CanBRASS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-06 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-01 du 08 mars 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-01_EcoStruxure_Control_Expert_and_EcoStruxure_Process_Expert_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-02 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-08 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-012-02 du 12 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-012-02_EcoStruxure_Power_Build_Rapsody_Security_Notification_V2.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-04 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-04_%20StruxureWare_Data_Center_Expert_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-01 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-05 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_Badalloc_Vulnerabilities_Security_Notification_V8.0.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-165-03 du 14 juin 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf"
}
]
}
GHSA-WRWF-2JPV-J2GV
Vulnerability from github – Published: 2022-05-24 17:40 – Updated: 2022-05-24 17:40A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.
{
"affected": [],
"aliases": [
"CVE-2021-22697"
],
"database_specific": {
"cwe_ids": [
"CWE-434"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-01-26T18:16:00Z",
"severity": "HIGH"
},
"details": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.",
"id": "GHSA-wrwf-2jpv-j2gv",
"modified": "2022-05-24T17:40:20Z",
"published": "2022-05-24T17:40:20Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-22697"
},
{
"type": "WEB",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01"
},
{
"type": "WEB",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02"
},
{
"type": "WEB",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-186"
}
],
"schema_version": "1.4.0",
"severity": []
}
GSD-2021-22697
Vulnerability from gsd - Updated: 2023-12-13 01:23{
"GSD": {
"alias": "CVE-2021-22697",
"description": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.",
"id": "GSD-2021-22697"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-22697"
],
"details": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.",
"id": "GSD-2021-22697",
"modified": "2023-12-13T01:23:24.731568Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22697",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "\u00a0EcoStruxure Power Build - Rapsody software V2.1.13 and prior.\u00a0",
"version": {
"version_data": [
{
"version_value": "EcoStruxure Power Build - Rapsody software V2.1.13 and prior."
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-434: Unrestricted Upload of File with Dangerous Type"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.1.13",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22697"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-434"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": true
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2022-01-31T19:33Z",
"publishedDate": "2021-01-26T18:16Z"
}
}
}
CVE-2021-22697
Vulnerability from csaf_se - Published: 2021-01-12 08:32 - Updated: 2022-06-14 18:30Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure Power Build - Rapsody product. \r\nThe EcoStruxure Power Build - Rapsody product is a LV switchboard configuration and quotation software to support users in the configuration and quotation process for Prisma switchboard projects in the non-critical building segment.\r\nFailure to apply the mitigations provided below may allow remote code execution which could result in serious interruption of business operations and exfiltration of credentials and other business sensitive data.\r\nJune 2022 Update: Remediation added",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "EcoStruxure Power Build - Rapsody - SEVD-2021-012-02 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2021-012-02.json"
},
{
"category": "self",
"summary": "EcoStruxure Power Build - Rapsody - SEVD-2021-012-02 PDF Version",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-012-02_EcoStruxure_Power_Build_Rapsody_Security_Notification_V2.0.pdf"
},
{
"category": "self",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "EcoStruxure Power Build - Rapsody",
"tracking": {
"current_release_date": "2022-06-14T18:30:00.000Z",
"generator": {
"date": "2022-06-14T18:30:00.000Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.1"
}
},
"id": "SEVD-2021-012-02",
"initial_release_date": "2021-01-12T08:32:35.000Z",
"revision_history": [
{
"date": "2021-01-12T08:32:35.000Z",
"number": "1",
"summary": "Original Release"
},
{
"date": "2022-06-14T08:32:35.000Z",
"number": "2",
"summary": "Final Remediations Added"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2.1.13",
"product": {
"name": "Schneider Electric EcoStruxure Power Build: Rapsody Software \u003cV2.1.13",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "EcoStruxure Power Build: Rapsody Software "
},
{
"branches": [
{
"category": "product_version",
"name": "V2.1.13",
"product": {
"name": "Schneider Electric EcoStruxure Power Build: Rapsody Software V2.1.13",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "EcoStruxure Power Build: Rapsody Software "
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"rgod"
],
"organization": "Trend Micro\u2019s Zero Day Initiative"
}
],
"cve": "CVE-2021-22697",
"cwe": {
"id": "CWE-434",
"name": "Unrestricted Upload of File with Dangerous Type"
},
"notes": [
{
"category": "description",
"text": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": " These vulnerabilities have been fixed in V2.1.13. Links to the fix versions in supported languages can be found below: \r\nhttps://www.se.com/us/en/faqs/FA379051/",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/faqs/FA379051/"
},
{
"category": "mitigation",
"details": "Customers should use appropriate patching methodologies when applying these patches to their systems.\r\nWe strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure.\r\nContact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch.\r\nIf customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:\r\nApply the principle of least privilege to limit access to the computer running the Rapsodysoftware to only those personnel that require access to it.\r\nInstall application allow list software on the computer to block the execution of maliciouscode.\r\nInstall anti-virus on the computer and keep it up to date.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2021-22697"
},
{
"acknowledgments": [
{
"names": [
"rgod"
],
"organization": "Trend Micro\u2019s Zero Day Initiative"
}
],
"cve": "CVE-2021-22698",
"cwe": {
"id": "CWE-434",
"name": "Unrestricted Upload of File with Dangerous Type"
},
"notes": [
{
"category": "description",
"text": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": " These vulnerabilities have been fixed in V2.1.13. Links to the fix versions in supported languages can be found below: \r\nhttps://www.se.com/us/en/faqs/FA379051/",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/faqs/FA379051/"
},
{
"category": "mitigation",
"details": "Customers should use appropriate patching methodologies when applying these patches to their systems.\r\nWe strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure.\r\nContact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch.\r\nIf customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:\r\nApply the principle of least privilege to limit access to the computer running the Rapsodysoftware to only those personnel that require access to it.\r\nInstall application allow list software on the computer to block the execution of maliciouscode.\r\nInstall anti-virus on the computer and keep it up to date.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2021-22698"
}
]
}
FKIE_CVE-2021-22697
Vulnerability from fkie_nvd - Published: 2021-01-26 18:16 - Updated: 2024-11-21 05:50| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01 | Third Party Advisory, US Government Resource | |
| cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2021-012-02/ | Vendor Advisory | |
| cybersecurity@se.com | https://www.zerodayinitiative.com/advisories/ZDI-21-186/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2021-012-02/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-21-186/ | Third Party Advisory, VDB Entry |
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | ecostruxure_power_build_-_rapsody | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_build_-_rapsody:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E458DE1E-6488-4F4A-BD96-7E46DA716BC5",
"versionEndIncluding": "2.1.13",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed."
},
{
"lang": "es",
"value": "CWE-434: Se presenta una vulnerabilidad de Carga Sin Restricciones de Archivo con Tipo Peligroso en el software EcoStruxure Power Build - Rapsody (versiones V2.1.13 y anteriores) que podr\u00eda permitir una condici\u00f3n de uso de la memoria previamente liberada que podr\u00eda resultar en una ejecuci\u00f3n de c\u00f3digo remota cuando un archivo SSD malicioso es cargado y analizado inapropiadamente"
}
],
"id": "CVE-2021-22697",
"lastModified": "2024-11-21T05:50:29.000",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-01-26T18:16:18.867",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-02/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-186/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-434"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
CNVD-2021-31180
Vulnerability from cnvd - Published: 2021-04-26厂商已发布了漏洞修复程序,请及时关注更新: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-012-02
| Name | Schneider Electric EcoStruxure Power Build-Rapsody <=V2.1.13 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2021-22697",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2021-22697"
}
},
"description": "Schneider Electric EcoStruxure Power Build-Rapsody\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u4e2a\u7528\u4e8e\u7b80\u5316\u4f4e\u538b\u914d\u7535\u76d8\u914d\u7f6e\u7684\u8f6f\u4ef6\u3002\n\nEcoStruxure Power Build-Rapsody V2.1.13\u7248\u672c\u53ca\u4e4b\u524d\u7248\u672c\u5b58\u5728\u4ee3\u7801\u95ee\u9898\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u7a0b\u5e8f\u9519\u8bef\u7684\u89e3\u6790\u4e86\u6076\u610fSSD\u6587\u4ef6\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u8fdc\u7a0b\u6267\u884c\u4efb\u610f\u4ee3\u7801\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-012-02",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2021-31180",
"openTime": "2021-04-26",
"patchDescription": "Schneider Electric EcoStruxure Power Build-Rapsody\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u4e2a\u7528\u4e8e\u7b80\u5316\u4f4e\u538b\u914d\u7535\u76d8\u914d\u7f6e\u7684\u8f6f\u4ef6\u3002\r\n\r\nEcoStruxure Power Build-Rapsody V2.1.13\u7248\u672c\u53ca\u4e4b\u524d\u7248\u672c\u5b58\u5728\u4ee3\u7801\u95ee\u9898\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u7a0b\u5e8f\u9519\u8bef\u7684\u89e3\u6790\u4e86\u6076\u610fSSD\u6587\u4ef6\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u8fdc\u7a0b\u6267\u884c\u4efb\u610f\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric EcoStruxure Power Build-Rapsody\u4ee3\u7801\u95ee\u9898\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Schneider Electric EcoStruxure Power Build-Rapsody \u003c=V2.1.13"
},
"referenceLink": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-01",
"serverity": "\u4e2d",
"submitTime": "2021-01-14",
"title": "Schneider Electric EcoStruxure Power Build-Rapsody\u4ee3\u7801\u95ee\u9898\u6f0f\u6d1e"
}
ICSA-21-012-01
Vulnerability from csaf_cisa - Published: 2021-01-12 00:00 - Updated: 2021-02-18 00:00Notes
{
"document": {
"acknowledgments": [
{
"names": [
"rgod"
],
"organization": "Trend Micro \u0027s Zero Day Initiative",
"summary": "reporting this vulnerability to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could allow a local attacker to upload a malicious SSD file, resulting in a use-after-free condition or a stack-based buffer overflow.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities, Energy, Food and Agriculture, Government Facilities, Transportation Systems, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-21-012-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-012-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-012-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-012-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric EcoStruxure Power Build-Rapsody (Update A)",
"tracking": {
"current_release_date": "2021-02-18T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-012-01",
"initial_release_date": "2021-01-12T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-01-12T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-21-012-01 Schneider Electric EcoStruxure Power Build - Rapsody"
},
{
"date": "2021-02-18T00:00:00.000000Z",
"legacy_version": "A",
"number": "2",
"summary": "ICSA-21-012-01 Schneider Electric EcoStruxure Power Build-Rapsody (Update A)"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 2.1.13",
"product": {
"name": "EcoStruxure Power Build-Rapsody software: Versions 2.1.13 and prior",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "EcoStruxure Power Build-Rapsody software"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-22697",
"cwe": {
"id": "CWE-434",
"name": "Unrestricted Upload of File with Dangerous Type"
},
"notes": [
{
"category": "summary",
"text": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22697"
},
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22698"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric reports fixes will be available in the first half of 2021. Until then, Schneider recommends affected users immediately apply the following mitigations to reduce the risk of exploit:",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Apply the principle of least privilege to limit access to the computer running the Rapsody software.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Install application whitelisting software on the computer to block the execution of malicious code.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Install antivirus on the computer and keep it up to date.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All updates, including details on affected products and remediation plans, can be found by subscribing to Schneider Electric\u0027s security notification service.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp"
},
{
"category": "mitigation",
"details": "For more information see the Schneider Electric advisory.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-01/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2021-22698",
"cwe": {
"id": "CWE-434",
"name": "Unrestricted Upload of File with Dangerous Type"
},
"notes": [
{
"category": "summary",
"text": "When a malicious SSD file is uploaded and improperly parsed, an attacker could cause a use-after-free condition or stack-based buffer overflow resulting in remote code execution.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22697"
},
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22698"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric reports fixes will be available in the first half of 2021. Until then, Schneider recommends affected users immediately apply the following mitigations to reduce the risk of exploit:",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Apply the principle of least privilege to limit access to the computer running the Rapsody software.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Install application whitelisting software on the computer to block the execution of malicious code.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Install antivirus on the computer and keep it up to date.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All updates, including details on affected products and remediation plans, can be found by subscribing to Schneider Electric\u0027s security notification service.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp"
},
{
"category": "mitigation",
"details": "For more information see the Schneider Electric advisory.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-012-01/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.