CVE-2018-5553
Vulnerability from cvelistv5
Published
2018-07-10 16:00
Modified
2024-09-16 22:20
Severity ?
EPSS score ?
Summary
The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:40:50.678Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "DGE-100", "vendor": "Crestron", "versions": [ { "lessThanOrEqual": "1.3384.00049.001", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "TS-1542-C", "vendor": "Crestron", "versions": [ { "lessThanOrEqual": "1.3384.00049.001", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "DM-DGE-200-C", "vendor": "Crestron", "versions": [ { "lessThanOrEqual": "1.3384.00049.001", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "This issue was discovered by Rapid7 researchers Cale Black and Jordan Larose. It is being disclosed in accordance Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/)." } ], "datePublic": "2018-06-12T00:00:00", "descriptions": [ { "lang": "en", "value": "The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 (Improper Neutralization of Special Elements used in an OS Command)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-07-10T15:57:01", "orgId": "9974b330-7714-4307-a722-5648477acda7", "shortName": "rapid7" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553" }, { "tags": [ "x_refsource_MISC" ], "url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/" } ], "solutions": [ { "lang": "en", "value": "Users should update affected devices to the latest firmware version (1.3384.00059.001 or higher) available from Crestron\u0027s product pages." } ], "source": { "advisory": "R7-2018-15", "discovery": "EXTERNAL" }, "title": "Crestron DGE-100 Console Command Injection (FIXED)", "x_legacyV4Record": { "CVE_data_meta": { "AKA": "", "ASSIGNER": "cve@rapid7.com", "DATE_PUBLIC": "2018-06-12T10:00:00.000Z", "ID": "CVE-2018-5553", "STATE": "PUBLIC", "TITLE": "Crestron DGE-100 Console Command Injection (FIXED)" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "DGE-100", "version": { "version_data": [ { "affected": "\u003c=", "platform": "", "version_affected": "\u003c=", "version_name": "", "version_value": "1.3384.00049.001" } ] } }, { "product_name": "TS-1542-C", "version": { "version_data": [ { "affected": "\u003c=", "platform": "", "version_affected": "\u003c=", "version_name": "", "version_value": "1.3384.00049.001" } ] } }, { "product_name": "DM-DGE-200-C", "version": { "version_data": [ { "affected": "\u003c=", "platform": "", "version_affected": "\u003c=", "version_name": "", "version_value": "1.3384.00049.001" } ] } } ] }, "vendor_name": "Crestron" } ] } }, "configuration": [], "credit": [ { "lang": "eng", "value": "This issue was discovered by Rapid7 researchers Cale Black and Jordan Larose. It is being disclosed in accordance Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/)." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access." } ] }, "exploit": [], "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-78 (Improper Neutralization of Special Elements used in an OS Command)" } ] } ] }, "references": { "reference_data": [ { "name": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553", "refsource": "CONFIRM", "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553" }, { "name": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/", "refsource": "MISC", "url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/" } ] }, "solution": [ { "lang": "en", "value": "Users should update affected devices to the latest firmware version (1.3384.00059.001 or higher) available from Crestron\u0027s product pages." } ], "source": { "advisory": "R7-2018-15", "defect": [], "discovery": "EXTERNAL" }, "work_around": [] } } }, "cveMetadata": { "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7", "assignerShortName": "rapid7", "cveId": "CVE-2018-5553", "datePublished": "2018-07-10T16:00:00Z", "dateReserved": "2018-01-12T00:00:00", "dateUpdated": "2024-09-16T22:20:46.752Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-5553\",\"sourceIdentifier\":\"cve@rapid7.com\",\"published\":\"2018-07-10T16:29:00.970\",\"lastModified\":\"2024-11-21T04:09:03.720\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access.\"},{\"lang\":\"es\",\"value\":\"El servicio Crestron Console en los dispositivos DGE-100, DM-DGE-200-C y TS-1542-C con la configuraci\u00f3n por defecto y ejecutando versiones del firmware 1.3384.00049.001 y anteriores es vulnerable a una inyecci\u00f3n de comandos que puede emplearse para obtener acceso a nivel root.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"cve@rapid7.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cve@rapid7.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:crestron:dge-100_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.3384.00049.001\",\"matchCriteriaId\":\"2F48676D-D566-45C5-965B-B20ED8F2817F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:dge-100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E5D6A6E8-4FF6-467F-8F59-5512DD5B0A2C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:crestron:dm-dge-200-c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.3384.00049.001\",\"matchCriteriaId\":\"9D0D4D4C-9AE5-4500-8531-691E766A3175\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:dm-dge-200-c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D0D4FFAC-0D1F-4D58-986B-3F402EE643AE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:crestron:ts-1542-c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.3384.00049.001\",\"matchCriteriaId\":\"8D4AA22E-4175-4B81-BC75-B88868785FD5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:ts-1542-c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B59A47EB-692A-47A0-B1CE-6967A18B7A37\"}]}]}],\"references\":[{\"url\":\"https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/\",\"source\":\"cve@rapid7.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553\",\"source\":\"cve@rapid7.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.