CVE-2018-19018
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01 | Mitigation, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01 | Mitigation, Third Party Advisory, US Government Resource |
Vendor | Product | Version | ||
---|---|---|---|---|
ICS-CERT | CX-Supervisor |
Version: Versions 3.42 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:23:08.584Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CX-Supervisor", "vendor": "ICS-CERT", "versions": [ { "status": "affected", "version": "Versions 3.42 and prior" } ] } ], "datePublic": "2019-01-17T00:00:00", "descriptions": [ { "lang": "en", "value": "An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-824", "description": "ACCESS OF UNINITIALIZED POINTER CWE-824", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-02-12T21:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2019-01-17T00:00:00", "ID": "CVE-2018-19018", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CX-Supervisor", "version": { "version_data": [ { "version_value": "Versions 3.42 and prior" } ] } } ] }, "vendor_name": "ICS-CERT" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "ACCESS OF UNINITIALIZED POINTER CWE-824" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-19018", "datePublished": "2019-02-12T22:00:00Z", "dateReserved": "2018-11-06T00:00:00", "dateUpdated": "2024-09-16T20:32:03.769Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-19018\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2019-02-12T22:29:00.343\",\"lastModified\":\"2024-11-21T03:57:10.610\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de acceso de puntero no inicializado en CX-Supervisor (versiones 3.42 y anteriores) podr\u00eda conducir a una confusi\u00f3n de tipos al procesar archivos de proyecto. Un atacante podr\u00eda emplear un archivo de proyecto especialmente manipulado para explotar y ejecutar c\u00f3digo con los privilegios de la aplicaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.3,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:P/I:P/A:P\",\"baseScore\":6.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":6.8,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-824\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-824\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:omron:cx-supervisor:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.42\",\"matchCriteriaId\":\"C2DD1E81-F104-4B6B-B6C5-3F84E33E31BF\"}]}]}],\"references\":[{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
ICSA-19-017-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Michael DePlante" ], "organization": "Trend Micro \u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to NCCIC" }, { "names": [ "Esteban Ruiz (mr_me)" ], "organization": "Source Incite", "summary": "reporting these vulnerabilities to NCCIC" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could result in a denial-of-service condition, and/or allow an attacker to achieve code execution with privileges within the context of the application.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Japan", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-19-017-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-017-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-19-017-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-017-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Omron CX-Supervisor (Update A)", "tracking": { "current_release_date": "2019-02-07T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-017-01", "initial_release_date": "2019-01-17T00:00:00.000000Z", "revision_history": [ { "date": "2019-01-17T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-19-017-01 Omron CX-Supervisor" }, { "date": "2019-02-07T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-19-017-01 Omron CX-Supervisor (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 3.42", "product": { "name": "CX-Supervisor: Versions 3.42 and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "CX-Supervisor" } ], "category": "vendor", "name": "Omron" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-19011", "cwe": { "id": "CWE-94", "name": "Improper Control of Generation of Code (\u0027Code Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The application can execute code that has been injected into a project file. An attacker could exploit this to execute code under the privileges of the application.CVE-2018-19011 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19011" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-19013", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An attacker could inject commands to delete files and/or delete the contents of a file on the device through a specially crafted project file.CVE-2018-19013 has been assigned to this vulnerability. A CVSS v3 base score of 5.0 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:L/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19013" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:L/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 5.0, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:L/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-19015", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An attacker could inject commands to launch programs and create, write, and read files on the device through a specially crafted project file. An attacker could exploit this to execute code under the privileges of the application.CVE-2018-19015 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19015" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-19017", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Several use after free vulnerabilities have been identified. When processing project files, the application fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.CVE-2018-19017 has been assigned to these vulnerabilities. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19017" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-19019", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "summary", "text": "A type confusion vulnerability exists when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.CVE-2018-19019 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19019" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-19018", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "An access of uninitialized pointer vulnerability could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.CVE-2018-19018 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19018" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-19020", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "When processing project files and tampering with the value of an offset, an attacker can force the application to read a value outside of an array.CVE-2018-19020 has been assigned to this vulnerability. A CVSS v3 base score of 2.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N)", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19020" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 2.8, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
icsa-19-017-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Michael DePlante" ], "organization": "Trend Micro \u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to NCCIC" }, { "names": [ "Esteban Ruiz (mr_me)" ], "organization": "Source Incite", "summary": "reporting these vulnerabilities to NCCIC" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could result in a denial-of-service condition, and/or allow an attacker to achieve code execution with privileges within the context of the application.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Japan", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-19-017-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-017-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-19-017-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-017-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Omron CX-Supervisor (Update A)", "tracking": { "current_release_date": "2019-02-07T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-017-01", "initial_release_date": "2019-01-17T00:00:00.000000Z", "revision_history": [ { "date": "2019-01-17T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-19-017-01 Omron CX-Supervisor" }, { "date": "2019-02-07T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-19-017-01 Omron CX-Supervisor (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 3.42", "product": { "name": "CX-Supervisor: Versions 3.42 and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "CX-Supervisor" } ], "category": "vendor", "name": "Omron" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-19011", "cwe": { "id": "CWE-94", "name": "Improper Control of Generation of Code (\u0027Code Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The application can execute code that has been injected into a project file. An attacker could exploit this to execute code under the privileges of the application.CVE-2018-19011 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19011" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-19013", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An attacker could inject commands to delete files and/or delete the contents of a file on the device through a specially crafted project file.CVE-2018-19013 has been assigned to this vulnerability. A CVSS v3 base score of 5.0 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:L/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19013" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:L/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 5.0, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:L/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-19015", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An attacker could inject commands to launch programs and create, write, and read files on the device through a specially crafted project file. An attacker could exploit this to execute code under the privileges of the application.CVE-2018-19015 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19015" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-19017", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Several use after free vulnerabilities have been identified. When processing project files, the application fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.CVE-2018-19017 has been assigned to these vulnerabilities. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19017" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-19019", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "summary", "text": "A type confusion vulnerability exists when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.CVE-2018-19019 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19019" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-19018", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "An access of uninitialized pointer vulnerability could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.CVE-2018-19018 has been assigned to this vulnerability. A CVSS v3 base score of 6.7 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19018" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-19020", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "When processing project files and tampering with the value of an offset, an attacker can force the application to read a value outside of an array.CVE-2018-19020 has been assigned to this vulnerability. A CVSS v3 base score of 2.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N)", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-19020" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Omron has released Version 3.5.0.11 of CX-Supervisor to address the reported vulnerabilities. To be protected, development projects must be upgraded and saved in the new format, then rebuilt in the latest 3.5.0.11 format.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" } ], "scores": [ { "cvss_v3": { "baseScore": 2.8, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
ghsa-cq7x-c2fj-552h
Vulnerability from github
An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
{ "affected": [], "aliases": [ "CVE-2018-19018" ], "database_specific": { "cwe_ids": [ "CWE-824" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2019-02-12T22:29:00Z", "severity": "HIGH" }, "details": "An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.", "id": "GHSA-cq7x-c2fj-552h", "modified": "2022-05-13T01:33:36Z", "published": "2022-05-13T01:33:36Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2018-19018" }, { "type": "WEB", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
fkie_cve-2018-19018
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01 | Mitigation, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01 | Mitigation, Third Party Advisory, US Government Resource |
Vendor | Product | Version | |
---|---|---|---|
omron | cx-supervisor | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:omron:cx-supervisor:*:*:*:*:*:*:*:*", "matchCriteriaId": "C2DD1E81-F104-4B6B-B6C5-3F84E33E31BF", "versionEndIncluding": "3.42", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application." }, { "lang": "es", "value": "Una vulnerabilidad de acceso de puntero no inicializado en CX-Supervisor (versiones 3.42 y anteriores) podr\u00eda conducir a una confusi\u00f3n de tipos al procesar archivos de proyecto. Un atacante podr\u00eda emplear un archivo de proyecto especialmente manipulado para explotar y ejecutar c\u00f3digo con los privilegios de la aplicaci\u00f3n." } ], "id": "CVE-2018-19018", "lastModified": "2024-11-21T03:57:10.610", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 1.3, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-02-12T22:29:00.343", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-824" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-824" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
gsd-2018-19018
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2018-19018", "description": "An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.", "id": "GSD-2018-19018" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2018-19018" ], "details": "An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.", "id": "GSD-2018-19018", "modified": "2023-12-13T01:22:38.701958Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2019-01-17T00:00:00", "ID": "CVE-2018-19018", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CX-Supervisor", "version": { "version_data": [ { "version_value": "Versions 3.42 and prior" } ] } } ] }, "vendor_name": "ICS-CERT" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "ACCESS OF UNINITIALIZED POINTER CWE-824" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:omron:cx-supervisor:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "3.42", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2018-19018" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-824" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01", "refsource": "MISC", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 1.3, "impactScore": 5.9 } }, "lastModifiedDate": "2019-10-09T23:37Z", "publishedDate": "2019-02-12T22:29Z" } } }
var-201902-0643
Vulnerability from variot
An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of OMRON CX-Supervisor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SCS files. The issue results from the lack of proper initialization of a pointer prior to accessing it. Omron CX-Supervisor is a visual machine controller produced by Omron Corporation of Japan. A security vulnerability exists in Omron CX-Supervisor 3.42 and earlier
Show details on source website{ "affected_products": { "_id": null, "data": [ { "_id": null, "model": "cx-supervisor", "scope": "lte", "trust": 1.0, "vendor": "omron", "version": "3.42" }, { "_id": null, "model": "cx-supervisor", "scope": "lte", "trust": 0.8, "vendor": "omron", "version": "version 3.42" }, { "_id": null, "model": "cx-supervisor", "scope": null, "trust": 0.7, "vendor": "omron", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-19-174" }, { "db": "JVNDB", "id": "JVNDB-2019-001051" }, { "db": "NVD", "id": "CVE-2018-19018" } ] }, "configurations": { "_id": null, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:omron:cx-supervisor", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-001051" } ] }, "credits": { "_id": null, "data": "Esteban Ruiz (mr_me) of Source Incite", "sources": [ { "db": "ZDI", "id": "ZDI-19-174" } ], "trust": 0.7 }, "cve": "CVE-2018-19018", "cvss": { "_id": null, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Local", "authentication": "Single", "author": "JPCERT/CC", "availabilityImpact": "Complete", "baseScore": 6.6, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "JVNDB-2019-001051", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 3.2, "userInteractionRequired": null, "vectorString": "AV:L/AC:M/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 6.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.8, "id": "CVE-2018-19018", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:N/AC:M/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Local", "authentication": "Single", "author": "JPCERT/CC", "availabilityImpact": "Complete", "baseScore": 4.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2019-001051", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:H/Au:S/C:N/I:P/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "High", "accessVector": "Local", "authentication": "Single", "author": "JPCERT/CC", "availabilityImpact": "Complete", "baseScore": 6.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "JVNDB-2019-001051", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:H/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "Single", "author": "JPCERT/CC", "availabilityImpact": "None", "baseScore": 1.7, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2019-001051", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 6.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.8, "id": "VHN-129635", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "Low", "attackVector": "Local", "author": "JPCERT/CC", "availabilityImpact": "High", "baseScore": 7.3, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2019-001051", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 3.2, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.3, "id": "CVE-2018-19018", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "High", "attackVector": "Local", "author": "JPCERT/CC", "availabilityImpact": "High", "baseScore": 5.0, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2019-001051", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:L/A:H", "version": "3.0" }, { "attackComplexity": "High", "attackVector": "Local", "author": "JPCERT/CC", "availabilityImpact": "High", "baseScore": 6.7, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2019-001051", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "JPCERT/CC", "availabilityImpact": "None", "baseScore": 2.8, "baseSeverity": "Low", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "JVNDB-2019-001051", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2018-19018", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 0.7, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "JPCERT/CC", "id": "JVNDB-2019-001051", "trust": 3.2, "value": "High" }, { "author": "JPCERT/CC", "id": "JVNDB-2019-001051", "trust": 1.6, "value": "Medium" }, { "author": "nvd@nist.gov", "id": "CVE-2018-19018", "trust": 1.0, "value": "HIGH" }, { "author": "JPCERT/CC", "id": "JVNDB-2019-001051", "trust": 0.8, "value": "Low" }, { "author": "ZDI", "id": "CVE-2018-19018", "trust": 0.7, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201902-510", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-129635", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-19-174" }, { "db": "VULHUB", "id": "VHN-129635" }, { "db": "JVNDB", "id": "JVNDB-2019-001051" }, { "db": "JVNDB", "id": "JVNDB-2019-001051" }, { "db": "JVNDB", "id": "JVNDB-2019-001051" }, { "db": "JVNDB", "id": "JVNDB-2019-001051" }, { "db": "JVNDB", "id": "JVNDB-2019-001051" }, { "db": "JVNDB", "id": "JVNDB-2019-001051" }, { "db": "JVNDB", "id": "JVNDB-2019-001051" }, { "db": "CNNVD", "id": "CNNVD-201902-510" }, { "db": "NVD", "id": "CVE-2018-19018" } ] }, "description": { "_id": null, "data": "An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of OMRON CX-Supervisor. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SCS files. The issue results from the lack of proper initialization of a pointer prior to accessing it. Omron CX-Supervisor is a visual machine controller produced by Omron Corporation of Japan. A security vulnerability exists in Omron CX-Supervisor 3.42 and earlier", "sources": [ { "db": "NVD", "id": "CVE-2018-19018" }, { "db": "JVNDB", "id": "JVNDB-2019-001051" }, { "db": "ZDI", "id": "ZDI-19-174" }, { "db": "VULHUB", "id": "VHN-129635" } ], "trust": 2.34 }, "external_ids": { "_id": null, "data": [ { "db": "NVD", "id": "CVE-2018-19018", "trust": 3.2 }, { "db": "ICS CERT", "id": "ICSA-19-017-01", "trust": 2.5 }, { "db": "JVN", "id": "JVNVU90014171", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-001051", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-6717", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-19-174", "trust": 0.7 }, { "db": "CNNVD", "id": "CNNVD-201902-510", "trust": 0.7 }, { "db": "VULHUB", "id": "VHN-129635", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-19-174" }, { "db": "VULHUB", "id": "VHN-129635" }, { "db": "JVNDB", "id": "JVNDB-2019-001051" }, { "db": "CNNVD", "id": "CNNVD-201902-510" }, { "db": "NVD", "id": "CVE-2018-19018" } ] }, "id": "VAR-201902-0643", "iot": { "_id": null, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-129635" } ], "trust": 0.6707546999999999 }, "last_update_date": "2024-11-23T22:21:50.701000Z", "patch": { "_id": null, "data": [ { "title": "Release Notes For CX-Supervisor 3.5", "trust": 0.8, "url": "https://www.myomron.com/index.php?action=kb\u0026article=1711" }, { "title": "Omron has issued an update to correct this vulnerability.", "trust": 0.7, "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-017-01" }, { "title": "Omron CX-Supervisor Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=89321" } ], "sources": [ { "db": "ZDI", "id": "ZDI-19-174" }, { "db": "JVNDB", "id": "JVNDB-2019-001051" }, { "db": "CNNVD", "id": "CNNVD-201902-510" } ] }, "problemtype_data": { "_id": null, "data": [ { "problemtype": "CWE-824", "trust": 1.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-129635" }, { "db": "NVD", "id": "CVE-2018-19018" } ] }, "references": { "_id": null, "data": [ { "trust": 3.2, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-017-01" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-19018" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-19019" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-19018" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-19020" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-19011" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-19013" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-19015" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-19017" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu90014171/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-19019" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-19020" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-19011" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-19013" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-19015" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-19017" } ], "sources": [ { "db": "ZDI", "id": "ZDI-19-174" }, { "db": "VULHUB", "id": "VHN-129635" }, { "db": "JVNDB", "id": "JVNDB-2019-001051" }, { "db": "CNNVD", "id": "CNNVD-201902-510" }, { "db": "NVD", "id": "CVE-2018-19018" } ] }, "sources": { "_id": null, "data": [ { "db": "ZDI", "id": "ZDI-19-174", "ident": null }, { "db": "VULHUB", "id": "VHN-129635", "ident": null }, { "db": "JVNDB", "id": "JVNDB-2019-001051", "ident": null }, { "db": "CNNVD", "id": "CNNVD-201902-510", "ident": null }, { "db": "NVD", "id": "CVE-2018-19018", "ident": null } ] }, "sources_release_date": { "_id": null, "data": [ { "date": "2019-02-08T00:00:00", "db": "ZDI", "id": "ZDI-19-174", "ident": null }, { "date": "2019-02-12T00:00:00", "db": "VULHUB", "id": "VHN-129635", "ident": null }, { "date": "2019-01-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-001051", "ident": null }, { "date": "2019-02-12T00:00:00", "db": "CNNVD", "id": "CNNVD-201902-510", "ident": null }, { "date": "2019-02-12T22:29:00.343000", "db": "NVD", "id": "CVE-2018-19018", "ident": null } ] }, "sources_update_date": { "_id": null, "data": [ { "date": "2019-02-08T00:00:00", "db": "ZDI", "id": "ZDI-19-174", "ident": null }, { "date": "2019-10-09T00:00:00", "db": "VULHUB", "id": "VHN-129635", "ident": null }, { "date": "2019-08-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-001051", "ident": null }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201902-510", "ident": null }, { "date": "2024-11-21T03:57:10.610000", "db": "NVD", "id": "CVE-2018-19018", "ident": null } ] }, "threat_type": { "_id": null, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-201902-510" } ], "trust": 0.6 }, "title": { "_id": null, "data": "OMRON CX-Supervisor Multiple vulnerabilities in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-001051" } ], "trust": 0.8 }, "type": { "_id": null, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201902-510" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.