CVE-2017-9369
Vulnerability from cvelistv5
Published
2017-11-14 21:00
Modified
2024-09-16 17:08
Severity ?
Summary
In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader.
Impacted products
Vendor Product Version
BlackBerry QNX Software Development Platform (QNX SDP) Version: 6.6.0
Version: 6.5.0 SP1 and earlier
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:02:44.381Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "QNX Software Development Platform (QNX SDP)",
          "vendor": "BlackBerry",
          "versions": [
            {
              "status": "affected",
              "version": "6.6.0"
            },
            {
              "status": "affected",
              "version": "6.5.0 SP1 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2017-11-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information disclosure across privilege barriers.",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-14T20:57:01",
        "orgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
        "shortName": "blackberry"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@blackberry.com",
          "DATE_PUBLIC": "2017-11-14T00:00:00",
          "ID": "CVE-2017-9369",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "QNX Software Development Platform (QNX SDP)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "6.6.0"
                          },
                          {
                            "version_value": "6.5.0 SP1 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "BlackBerry"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Information disclosure across privilege barriers."
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674",
              "refsource": "CONFIRM",
              "url": "http://support.blackberry.com/kb/articleDetail?articleNumber=000046674"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dbe78b00-5e7b-4fda-8748-329789ecfc5c",
    "assignerShortName": "blackberry",
    "cveId": "CVE-2017-9369",
    "datePublished": "2017-11-14T21:00:00Z",
    "dateReserved": "2017-06-02T00:00:00",
    "dateUpdated": "2024-09-16T17:08:03.615Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2017-9369\",\"sourceIdentifier\":\"secure@blackberry.com\",\"published\":\"2017-11-14T21:29:00.967\",\"lastModified\":\"2024-11-21T03:35:56.410\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In BlackBerry QNX Software Development Platform (SDP) 6.6.0 and 6.5.0 SP1 and earlier, an information disclosure vulnerability in the default configuration of the QNX SDP could allow an attacker to gain information relating to memory layout of higher privileged processes by manipulating environment variables that influence the loader.\"},{\"lang\":\"es\",\"value\":\"En BlackBerry QNX Software Development Platform (SDP) 6.6.0 y 6.5.0 SP1 y anteriores, una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n en la configuraci\u00f3n por defecto de la plataforma QNX SDP podr\u00eda permitir que un atacante obtenga informaci\u00f3n relacionada con el dise\u00f1o de la memoria de procesos con mayores privilegios mediante la manipulaci\u00f3n de variables de entorno que influyen en el cargador.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":4.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.2,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:blackberry:qnx_software_development_platform:6.5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1766E1E7-19FE-45A5-8191-BA0CF84BB768\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:blackberry:qnx_software_development_platform:6.5.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"11F2C680-2F44-4CBC-BC7E-B608726302D2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:blackberry:qnx_software_development_platform:6.6.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FF1D7FB0-C40B-4DD6-B3C5-D90FBCCBAF23\"}]}]}],\"references\":[{\"url\":\"http://support.blackberry.com/kb/articleDetail?articleNumber=000046674\",\"source\":\"secure@blackberry.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"http://support.blackberry.com/kb/articleDetail?articleNumber=000046674\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.