GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2016-7114 (GCVE-0-2016-7114)

Vulnerability from cvelistv5 – Published: 2016-09-06 00:00 – Updated: 2024-09-16 22:50
VLAI
Summary
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.87; SIPROTEC 7UT686 : All versions < V 4.02; SIPROTEC 7SD686 : All versions < V 4.05; SIPROTEC 7SJ66 : All versions < V 4.30. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.
CWE
  • n/a
Date Public
2017-07-04 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T01:50:47.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "92745",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/92745"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
          },
          {
            "name": "99471",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99471"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-04T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.87; SIPROTEC 7UT686 : All versions \u003c V 4.02; SIPROTEC 7SD686 : All versions \u003c V 4.05; SIPROTEC 7SJ66 : All versions \u003c V 4.30. Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T17:57:01.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "92745",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/92745"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
        },
        {
          "name": "99471",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99471"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2017-07-04T00:00:00",
          "ID": "CVE-2016-7114",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.87; SIPROTEC 7UT686 : All versions \u003c V 4.02; SIPROTEC 7SD686 : All versions \u003c V 4.05; SIPROTEC 7SJ66 : All versions \u003c V 4.30. Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "92745",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/92745"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
            },
            {
              "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
            },
            {
              "name": "99471",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99471"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-7114",
    "datePublished": "2016-09-06T00:00:00.000Z",
    "dateReserved": "2016-08-30T00:00:00.000Z",
    "dateUpdated": "2024-09-16T22:50:42.737Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2016-7114",
      "date": "2026-09-18",
      "epss": "0.02113",
      "percentile": "0.8097"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:en100_ethernet_module_firmware:4.28:*:*:*:*:*:*:*",
                  "matchCriteriaId": "862476A4-6C97-4E00-9EC1-5EEA8A27EE73",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:en100_ethernet_module:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DAC429FD-7148-4A68-AA81-8FBADA588F4E",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.87; SIPROTEC 7UT686 : All versions \u003c V 4.02; SIPROTEC 7SD686 : All versions \u003c V 4.05; SIPROTEC 7SJ66 : All versions \u003c V 4.30. Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el m\u00f3dulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02; SIPROTEC 7SJ686: todas las versiones anteriores a la V 4.87 y SIPROTEC 7UT686: todas las versiones anteriores a la V 4.02 y SIPROTEC 7SD686: todas las versiones anteriores a la V 4.05 y SIPROTEC 7SJ66: todas las versiones anteriores a la V 4.30. Los atacantes que tengan acceso de red a la interfaz web del dispositivo (puerto 80/tcp) podr\u00edan omitir la autenticaci\u00f3n y realizar ciertas operaciones administrativas. Un usuario leg\u00edtimo debe tener la sesi\u00f3n iniciada en la interfaz web para que el ataque tenga \u00e9xito."
        }
      ],
      "id": "CVE-2016-7114",
      "lastModified": "2024-11-21T02:57:29.550",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 9.0,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2016-09-06T00:59:02.977",
      "references": [
        {
          "source": "cve@mitre.org",
          "url": "http://www.securityfocus.com/bid/92745"
        },
        {
          "source": "cve@mitre.org",
          "url": "http://www.securityfocus.com/bid/99471"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "http://www.securityfocus.com/bid/92745"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "http://www.securityfocus.com/bid/99471"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-287"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:en100_ethernet_module_firmware:4.28:*:*:*:*:*:*:*",
                    "matchCriteriaId": "862476A4-6C97-4E00-9EC1-5EEA8A27EE73",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:en100_ethernet_module:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DAC429FD-7148-4A68-AA81-8FBADA588F4E",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.87; SIPROTEC 7UT686 : All versions \u003c V 4.02; SIPROTEC 7SD686 : All versions \u003c V 4.05; SIPROTEC 7SJ66 : All versions \u003c V 4.30. Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful."
          },
          {
            "lang": "es",
            "value": "Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el m\u00f3dulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02; SIPROTEC 7SJ686: todas las versiones anteriores a la V 4.87 y SIPROTEC 7UT686: todas las versiones anteriores a la V 4.02 y SIPROTEC 7SD686: todas las versiones anteriores a la V 4.05 y SIPROTEC 7SJ66: todas las versiones anteriores a la V 4.30. Los atacantes que tengan acceso de red a la interfaz web del dispositivo (puerto 80/tcp) podr\u00edan omitir la autenticaci\u00f3n y realizar ciertas operaciones administrativas. Un usuario leg\u00edtimo debe tener la sesi\u00f3n iniciada en la interfaz web para que el ataque tenga \u00e9xito."
          }
        ],
        "id": "CVE-2016-7114",
        "lastModified": "2026-05-06T22:30:45.220",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2016-09-06T00:59:02.977",
        "references": [
          {
            "source": "cve@mitre.org",
            "url": "http://www.securityfocus.com/bid/92745"
          },
          {
            "source": "cve@mitre.org",
            "url": "http://www.securityfocus.com/bid/99471"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
          },
          {
            "source": "cve@mitre.org",
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
          },
          {
            "source": "cve@mitre.org",
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "http://www.securityfocus.com/bid/92745"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "http://www.securityfocus.com/bid/99471"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-287"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…