CVE-2012-1802 (GCVE-0-2012-1802)

Vulnerability from cvelistv5 – Published: 2012-04-18 10:00 – Updated: 2024-08-06 19:08
VLAI
Summary
Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.
Severity
No CVSS data available.
CWE
  • n/a
Assigner
certcc CNA under the mitre root
CNA scorecard E 42/100 over 157 records in the last 180 days details
References
Date Public
2012-04-11 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:08:38.499Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "81032",
            "tags": [
              "vdb-entry",
              "x_refsource_OSVDB",
              "x_transferred"
            ],
            "url": "http://osvdb.org/81032"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2012-04-11T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-11-20T10:00:00.000Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "name": "81032",
          "tags": [
            "vdb-entry",
            "x_refsource_OSVDB"
          ],
          "url": "http://osvdb.org/81032"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2012-1802",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "81032",
              "refsource": "OSVDB",
              "url": "http://osvdb.org/81032"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf"
            },
            {
              "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2012-1802",
    "datePublished": "2012-04-18T10:00:00.000Z",
    "dateReserved": "2012-03-21T00:00:00.000Z",
    "dateUpdated": "2024-08-06T19:08:38.499Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2012-1802",
      "date": "2026-10-15",
      "epss": "0.06052",
      "percentile": "0.93279"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FB47C02A-0FD8-47A2-93F8-310A5E05E19F",
                  "versionEndIncluding": "3.7.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:1.2.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6212D6C3-A68D-41BA-929A-943A157B3BA7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.1.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "56338A9A-C59D-47D3-9AB4-18C53A75EDD5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.2.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "801D7741-8EBB-4A68-A77C-E26C304EB988",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.3.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EF4AB664-29DD-46F0-B136-8BD458430BD4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.3.3:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB8720F3-21D3-40C1-98A8-90E2EF6BBA52",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.0.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF99DC1-34B7-4AAA-BC33-5763B56EEA1B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "629D65C2-0D61-48BD-9C73-7794AC061756",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.3.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DDD5708A-0105-4129-B5A6-DAF0247ABE1F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.4.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B349A4F6-1FB0-433B-B512-883E580CFB27",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_x414-3e:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6645288F-F688-442A-8C56-17536BFAD4BE",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EC42F509-F58D-4A65-9C31-26F0C7319076",
                  "versionEndIncluding": "3.7.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.1.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4020E0F4-E92A-442D-A703-CA8840B8D944",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "58E635A6-1AFF-4A34-87F3-F68571032448",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.5.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BB1B5735-D3C0-445C-B7D5-A3099D1CE152",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AC54911E-C432-48FA-9551-9644422FFE14",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x-300eec_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6F13D012-86FA-4A41-8D18-94942A270DAA",
                  "versionEndIncluding": "3.7.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x-300eec_firmware:3.5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BB16E154-1E59-438F-9895-47260FDD7230",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_x-300eec:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F2F32466-A411-4D69-864A-4434D3D5DB54",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FF530C3C-A126-4F6A-8010-E93352800598",
                  "versionEndIncluding": "3.7.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_xr-300_firmware:3.1.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AE3F5ED9-F357-430C-B277-B7EC0715A391",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_xr-300_firmware:3.5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "61FF9CF2-14CD-49BF-AC0B-0D2E0EDCF79F",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "889CF2C0-EE6C-447F-85F1-005730EAD232",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F2000A16-E8A2-4E8E-A90F-4E0F62F3993C",
                  "versionEndIncluding": "3.7.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:2.2.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AF93BD72-2893-436D-A514-3C463C1AA428",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:2.3.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "59323828-6A3A-48CD-B98C-64CD65829471",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:3.0.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C8C53B2B-BFFC-47D1-B935-FF85F5A4D3F1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:3.3.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "054C0618-5CA9-43E4-A557-0064B8BB5B63",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:3.5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6D5DF242-8FD0-467C-84D1-5207CC15D2D2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:3.5.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B16E873A-5D79-43B8-BB64-66B8079CFCC4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B2D0AB50-6F0B-4232-8C8E-1647410D362D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL."
        },
        {
          "lang": "es",
          "value": "Desbordamiento de b\u00fafer en el servidor web integrado en el conmutador ethernet industrial Siemens Scalance X X414-3E antes de v3.7.1, X308-2M antes de v3.7.2, X-300EEC antes de v3.7.2, XR-300 antes de v3.7.2, y X-300 antes de v3.7.2 permite a atacantes remotos causar una denegaci\u00f3n de servicio (reinicio del dispositivo) o posiblemente ejecutar c\u00f3digo arbitrario a trav\u00e9s de una direcci\u00f3n URL incorrecta."
        }
      ],
      "id": "CVE-2012-1802",
      "lastModified": "2024-11-21T01:37:48.693",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 7.8,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ]
      },
      "published": "2012-04-18T10:33:35.450",
      "references": [
        {
          "source": "cret@cert.org",
          "url": "http://osvdb.org/81032"
        },
        {
          "source": "cret@cert.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf"
        },
        {
          "source": "cret@cert.org",
          "tags": [
            "US Government Resource"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "http://osvdb.org/81032"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "US Government Resource"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf"
        }
      ],
      "sourceIdentifier": "cret@cert.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FB47C02A-0FD8-47A2-93F8-310A5E05E19F",
                    "versionEndIncluding": "3.7.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:1.2.2:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6212D6C3-A68D-41BA-929A-943A157B3BA7",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.1.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "56338A9A-C59D-47D3-9AB4-18C53A75EDD5",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.2.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "801D7741-8EBB-4A68-A77C-E26C304EB988",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.3.2:*:*:*:*:*:*:*",
                    "matchCriteriaId": "EF4AB664-29DD-46F0-B136-8BD458430BD4",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.3.3:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DB8720F3-21D3-40C1-98A8-90E2EF6BBA52",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.0.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FFF99DC1-34B7-4AAA-BC33-5763B56EEA1B",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.0.2:*:*:*:*:*:*:*",
                    "matchCriteriaId": "629D65C2-0D61-48BD-9C73-7794AC061756",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.3.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DDD5708A-0105-4129-B5A6-DAF0247ABE1F",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.4.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B349A4F6-1FB0-433B-B512-883E580CFB27",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:scalance_x414-3e:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6645288F-F688-442A-8C56-17536BFAD4BE",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "EC42F509-F58D-4A65-9C31-26F0C7319076",
                    "versionEndIncluding": "3.7.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.1.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4020E0F4-E92A-442D-A703-CA8840B8D944",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.5.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "58E635A6-1AFF-4A34-87F3-F68571032448",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.5.2:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BB1B5735-D3C0-445C-B7D5-A3099D1CE152",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AC54911E-C432-48FA-9551-9644422FFE14",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x-300eec_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6F13D012-86FA-4A41-8D18-94942A270DAA",
                    "versionEndIncluding": "3.7.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x-300eec_firmware:3.5.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BB16E154-1E59-438F-9895-47260FDD7230",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:scalance_x-300eec:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F2F32466-A411-4D69-864A-4434D3D5DB54",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FF530C3C-A126-4F6A-8010-E93352800598",
                    "versionEndIncluding": "3.7.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_xr-300_firmware:3.1.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AE3F5ED9-F357-430C-B277-B7EC0715A391",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_xr-300_firmware:3.5.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "61FF9CF2-14CD-49BF-AC0B-0D2E0EDCF79F",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "889CF2C0-EE6C-447F-85F1-005730EAD232",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F2000A16-E8A2-4E8E-A90F-4E0F62F3993C",
                    "versionEndIncluding": "3.7.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:2.2.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AF93BD72-2893-436D-A514-3C463C1AA428",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:2.3.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "59323828-6A3A-48CD-B98C-64CD65829471",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:3.0.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C8C53B2B-BFFC-47D1-B935-FF85F5A4D3F1",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:3.3.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "054C0618-5CA9-43E4-A557-0064B8BB5B63",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:3.5.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6D5DF242-8FD0-467C-84D1-5207CC15D2D2",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:3.5.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B16E873A-5D79-43B8-BB64-66B8079CFCC4",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B2D0AB50-6F0B-4232-8C8E-1647410D362D",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL."
          },
          {
            "lang": "es",
            "value": "Desbordamiento de b\u00fafer en el servidor web integrado en el conmutador ethernet industrial Siemens Scalance X X414-3E antes de v3.7.1, X308-2M antes de v3.7.2, X-300EEC antes de v3.7.2, XR-300 antes de v3.7.2, y X-300 antes de v3.7.2 permite a atacantes remotos causar una denegaci\u00f3n de servicio (reinicio del dispositivo) o posiblemente ejecutar c\u00f3digo arbitrario a trav\u00e9s de una direcci\u00f3n URL incorrecta."
          }
        ],
        "id": "CVE-2012-1802",
        "lastModified": "2026-04-29T01:13:23.040",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 6.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ]
        },
        "published": "2012-04-18T10:33:35.450",
        "references": [
          {
            "source": "cret@cert.org",
            "url": "http://osvdb.org/81032"
          },
          {
            "source": "cret@cert.org",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf"
          },
          {
            "source": "cret@cert.org",
            "tags": [
              "US Government Resource"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "http://osvdb.org/81032"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "US Government Resource"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf"
          }
        ],
        "sourceIdentifier": "cret@cert.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-119"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.