Find a vulnerability
Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
5 vulnerabilities by sdg
VAR-202102-0214
Vulnerability from variot - Updated: 2023-12-18 13:07PNPSCADA 2.200816204020 allows cross-site scripting (XSS), which can execute arbitrary JavaScript in the victim's browser. PNPSCADA Contains a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. SDG Technologies Plug and Play SCADA fails to adequately filter user-submitted input, allowing remote attackers to exploit vulnerabilities to inject malicious scripts or HTML code to capture sensitive information or hijack user sessions when malicious data is viewed. SDG Technologies Plug and Play SCADA is a set of Web-based SCADA (Data Acquisition and Monitoring Control) and HMI software used by SDG Technologies of South Africa in the energy industry. A cross-site scripting vulnerability exists in the SDG Technologies Plug and Play SCADA, which is caused by the program's insufficient filtering of user-submitted input. When a user browses an affected website, their browser executes arbitrary script code provided by the attacker. This could lead to attackers stealing cookie-based authentication and launching other attacks
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202102-0214",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "pnpscada",
"scope": "eq",
"trust": 1.0,
"vendor": "sdgc",
"version": "2.200816204020"
},
{
"model": "plug and play scada",
"scope": "eq",
"trust": 0.8,
"vendor": "sdg",
"version": "2.200816204020"
},
{
"model": "plug and play scada",
"scope": "eq",
"trust": 0.8,
"vendor": "sdg",
"version": null
},
{
"model": "cc plug and play scada",
"scope": null,
"trust": 0.6,
"vendor": "sdg",
"version": null
},
{
"model": "plug and play scada",
"scope": "eq",
"trust": 0.3,
"vendor": "sdg",
"version": "0"
},
{
"model": "cc plug and play scada",
"scope": "eq",
"trust": 0.2,
"vendor": "sdg",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "487d24e6-1e5b-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-07268"
},
{
"db": "BID",
"id": "77109"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-015941"
},
{
"db": "NVD",
"id": "CVE-2020-24842"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:sdgc:pnpscada:2.200816204020:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-24842"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Kelvin Security",
"sources": [
{
"db": "BID",
"id": "77109"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-709"
}
],
"trust": 0.9
},
"cve": "CVE-2020-24842",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.3,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2020-24842",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "CNVD-2015-07268",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "487d24e6-1e5b-11e6-abef-000c29c66e3d",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.9 [IVD]"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 6.1,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2020-24842",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-24842",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2015-07268",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202102-1026",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "487d24e6-1e5b-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "487d24e6-1e5b-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-07268"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-015941"
},
{
"db": "NVD",
"id": "CVE-2020-24842"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1026"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "PNPSCADA 2.200816204020 allows cross-site scripting (XSS), which can execute arbitrary JavaScript in the victim\u0027s browser. PNPSCADA Contains a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. SDG Technologies Plug and Play SCADA fails to adequately filter user-submitted input, allowing remote attackers to exploit vulnerabilities to inject malicious scripts or HTML code to capture sensitive information or hijack user sessions when malicious data is viewed. SDG Technologies Plug and Play SCADA is a set of Web-based SCADA (Data Acquisition and Monitoring Control) and HMI software used by SDG Technologies of South Africa in the energy industry. \nA cross-site scripting vulnerability exists in the SDG Technologies Plug and Play SCADA, which is caused by the program\u0027s insufficient filtering of user-submitted input. When a user browses an affected website, their browser executes arbitrary script code provided by the attacker. This could lead to attackers stealing cookie-based authentication and launching other attacks",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-24842"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-015941"
},
{
"db": "CNVD",
"id": "CNVD-2015-07268"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-709"
},
{
"db": "BID",
"id": "77109"
},
{
"db": "IVD",
"id": "487d24e6-1e5b-11e6-abef-000c29c66e3d"
}
],
"trust": 3.15
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ICS CERT ALERT",
"id": "ICS-ALERT-15-288-01",
"trust": 2.7
},
{
"db": "NVD",
"id": "CVE-2020-24842",
"trust": 2.4
},
{
"db": "BID",
"id": "77109",
"trust": 1.5
},
{
"db": "CNVD",
"id": "CNVD-2015-07268",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-015941",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201510-709",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1026",
"trust": 0.6
},
{
"db": "IVD",
"id": "487D24E6-1E5B-11E6-ABEF-000C29C66E3D",
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "487d24e6-1e5b-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-07268"
},
{
"db": "BID",
"id": "77109"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-015941"
},
{
"db": "NVD",
"id": "CVE-2020-24842"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-709"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1026"
}
]
},
"id": "VAR-202102-0214",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "487d24e6-1e5b-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-07268"
}
],
"trust": 1.8
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "487d24e6-1e5b-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-07268"
}
]
},
"last_update_date": "2023-12-18T13:07:18.375000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://sdg.pnpscada.com/home.html"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-015941"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.0
},
{
"problemtype": "Cross-site scripting (CWE-79) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-015941"
},
{
"db": "NVD",
"id": "CVE-2020-24842"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://us-cert.cisa.gov/ics/alerts/ics-alert-15-288-01"
},
{
"trust": 1.2,
"url": "http://www.securityfocus.com/bid/77109"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-24842"
},
{
"trust": 0.3,
"url": "http://www.pnpscada.com/about.html"
},
{
"trust": 0.3,
"url": "https://ics-cert.us-cert.gov/alerts/ics-alert-15-288-01"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-07268"
},
{
"db": "BID",
"id": "77109"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-015941"
},
{
"db": "NVD",
"id": "CVE-2020-24842"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-709"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1026"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "487d24e6-1e5b-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-07268"
},
{
"db": "BID",
"id": "77109"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-015941"
},
{
"db": "NVD",
"id": "CVE-2020-24842"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-709"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1026"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-11-05T00:00:00",
"db": "IVD",
"id": "487d24e6-1e5b-11e6-abef-000c29c66e3d"
},
{
"date": "2015-11-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-07268"
},
{
"date": "2015-10-15T00:00:00",
"db": "BID",
"id": "77109"
},
{
"date": "2021-10-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-015941"
},
{
"date": "2021-02-10T22:15:13.343000",
"db": "NVD",
"id": "CVE-2020-24842"
},
{
"date": "2015-10-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201510-709"
},
{
"date": "2021-02-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1026"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-11-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-07268"
},
{
"date": "2015-10-15T00:00:00",
"db": "BID",
"id": "77109"
},
{
"date": "2021-10-25T09:06:00",
"db": "JVNDB",
"id": "JVNDB-2020-015941"
},
{
"date": "2021-02-13T02:38:56.747000",
"db": "NVD",
"id": "CVE-2020-24842"
},
{
"date": "2015-10-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201510-709"
},
{
"date": "2021-02-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202102-1026"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201510-709"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1026"
}
],
"trust": 1.2
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SDG Technologies Plug and Play SCADA Cross-Site Scripting Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-07268"
},
{
"db": "CNNVD",
"id": "CNNVD-201510-709"
}
],
"trust": 1.2
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201510-709"
},
{
"db": "CNNVD",
"id": "CNNVD-202102-1026"
}
],
"trust": 1.2
}
}
CVE-2023-1934 (GCVE-0-2023-1934)
Vulnerability from nvd – Published: 2023-05-12 13:18 – Updated: 2025-02-13 16:39- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
| Vendor | Product | Version | |
|---|---|---|---|
| SDG Technologies | PnPSCADA |
Affected:
2.*
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:05:26.708Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-12"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/172511/PnPSCADA-2.x-SQL-Injection.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-1934",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:58:22.860030Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T21:35:16.169Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PnPSCADA",
"vendor": "SDG Technologies",
"versions": [
{
"status": "affected",
"version": "2.*"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Momen Eldawakhly of Samurai Digital Security Ltd reported this vulnerability to CISA."
}
],
"datePublic": "2023-05-11T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe PnPSCADA system, a product of SDG Technologies CC, is afflicted by a critical unauthenticated error-based PostgreSQL Injection vulnerability. Present within the hitlogcsv.jsp endpoint, this security flaw permits unauthenticated attackers to engage with the underlying database seamlessly and passively. Consequently, malicious actors could gain access to vital information, such as Industrial Control System (ICS) and OT data, alongside other sensitive records like SMS and SMS Logs. The unauthorized database access exposes compromised systems to potential manipulation or breach of essential infrastructure data, highlighting the severity of this vulnerability.\u003c/span\u003e"
}
],
"value": "The PnPSCADA system, a product of SDG Technologies CC, is afflicted by a critical unauthenticated error-based PostgreSQL Injection vulnerability. Present within the hitlogcsv.jsp endpoint, this security flaw permits unauthenticated attackers to engage with the underlying database seamlessly and passively. Consequently, malicious actors could gain access to vital information, such as Industrial Control System (ICS) and OT data, alongside other sensitive records like SMS and SMS Logs. The unauthorized database access exposes compromised systems to potential manipulation or breach of essential infrastructure data, highlighting the severity of this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-24T17:06:21.136Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-12"
},
{
"url": "http://packetstormsecurity.com/files/172511/PnPSCADA-2.x-SQL-Injection.html"
}
],
"source": {
"advisory": "ICSA-23-131-12",
"discovery": "EXTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eSDG PnpSCADA is aware of the issue and is currently developing a fix. For more information, contact PnpSCADA by \u003ca target=\"_blank\" rel=\"nofollow\"\u003eemail\u003c/a\u003e.\u003c/p\u003e\u003cp\u003eThe following workarounds are recommended to help reduce the risk:\u003c/p\u003e\u003cul\u003e\u003cli\u003eUse prepared statements to help prevent SQL injections.\u003c/li\u003e\u003cli\u003eAvoid making assets publicly accessible.\u003c/li\u003e\u003cli\u003eRestrict public access: As a primary mitigation, it is crucial for all PnPSCADA users to avoid exposing their SCADA systems to the internet. By implementing proper network segmentation and isolating the SCADA system from public networks, users can significantly reduce the risk of unauthorized access and exploitation.\u003c/li\u003e\u003cli\u003eImplement strong access controls: Ensure that proper authentication and authorization mechanisms are in place to limit access to sensitive components of the SCADA system. This includes implementing role-based access control and regular audits of user privileges.\u003c/li\u003e\u003cli\u003eMonitor and log activity: Continuously monitor and log all activities within the SCADA environment. This helps with detecting any potential unauthorized access or attempts to exploit the vulnerability, enabling timely response and mitigation.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "SDG PnpSCADA is aware of the issue and is currently developing a fix. For more information, contact PnpSCADA by email.\n\nThe following workarounds are recommended to help reduce the risk:\n\n * Use prepared statements to help prevent SQL injections.\n * Avoid making assets publicly accessible.\n * Restrict public access: As a primary mitigation, it is crucial for all PnPSCADA users to avoid exposing their SCADA systems to the internet. By implementing proper network segmentation and isolating the SCADA system from public networks, users can significantly reduce the risk of unauthorized access and exploitation.\n * Implement strong access controls: Ensure that proper authentication and authorization mechanisms are in place to limit access to sensitive components of the SCADA system. This includes implementing role-based access control and regular audits of user privileges.\n * Monitor and log activity: Continuously monitor and log all activities within the SCADA environment. This helps with detecting any potential unauthorized access or attempts to exploit the vulnerability, enabling timely response and mitigation."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-1934",
"datePublished": "2023-05-12T13:18:25.512Z",
"dateReserved": "2023-04-06T23:59:34.451Z",
"dateUpdated": "2025-02-13T16:39:43.283Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-24841 (GCVE-0-2020-24841)
Vulnerability from nvd – Published: 2021-02-16 12:25 – Updated: 2026-07-09 00:11- n/a
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2026-07-09T00:11:02.079Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/48757"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "PNPSCADA 2.200816204020 allows SQL injection via parameter \u0027interf\u0027 in /browse.jsp. Exploiting this issue could allow an attacker to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-04T23:54:38.692Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.exploit-db.com/exploits/48757"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-24841",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "PNPSCADA 2.200816204020 allows SQL injection via parameter \u0027interf\u0027 in /browse.jsp. Exploiting this issue could allow an attacker to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://sdg.com",
"refsource": "MISC",
"url": "http://sdg.com"
},
{
"name": "https://www.exploit-db.com/exploits/48757",
"refsource": "MISC",
"url": "https://www.exploit-db.com/exploits/48757"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-24841",
"datePublished": "2021-02-16T12:25:39.000Z",
"dateReserved": "2020-08-28T00:00:00.000Z",
"dateUpdated": "2026-07-09T00:11:02.079Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-1934 (GCVE-0-2023-1934)
Vulnerability from cvelistv5 – Published: 2023-05-12 13:18 – Updated: 2025-02-13 16:39- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
| Vendor | Product | Version | |
|---|---|---|---|
| SDG Technologies | PnPSCADA |
Affected:
2.*
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:05:26.708Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-12"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/172511/PnPSCADA-2.x-SQL-Injection.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-1934",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-16T20:58:22.860030Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T21:35:16.169Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PnPSCADA",
"vendor": "SDG Technologies",
"versions": [
{
"status": "affected",
"version": "2.*"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Momen Eldawakhly of Samurai Digital Security Ltd reported this vulnerability to CISA."
}
],
"datePublic": "2023-05-11T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe PnPSCADA system, a product of SDG Technologies CC, is afflicted by a critical unauthenticated error-based PostgreSQL Injection vulnerability. Present within the hitlogcsv.jsp endpoint, this security flaw permits unauthenticated attackers to engage with the underlying database seamlessly and passively. Consequently, malicious actors could gain access to vital information, such as Industrial Control System (ICS) and OT data, alongside other sensitive records like SMS and SMS Logs. The unauthorized database access exposes compromised systems to potential manipulation or breach of essential infrastructure data, highlighting the severity of this vulnerability.\u003c/span\u003e"
}
],
"value": "The PnPSCADA system, a product of SDG Technologies CC, is afflicted by a critical unauthenticated error-based PostgreSQL Injection vulnerability. Present within the hitlogcsv.jsp endpoint, this security flaw permits unauthenticated attackers to engage with the underlying database seamlessly and passively. Consequently, malicious actors could gain access to vital information, such as Industrial Control System (ICS) and OT data, alongside other sensitive records like SMS and SMS Logs. The unauthorized database access exposes compromised systems to potential manipulation or breach of essential infrastructure data, highlighting the severity of this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-24T17:06:21.136Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-12"
},
{
"url": "http://packetstormsecurity.com/files/172511/PnPSCADA-2.x-SQL-Injection.html"
}
],
"source": {
"advisory": "ICSA-23-131-12",
"discovery": "EXTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eSDG PnpSCADA is aware of the issue and is currently developing a fix. For more information, contact PnpSCADA by \u003ca target=\"_blank\" rel=\"nofollow\"\u003eemail\u003c/a\u003e.\u003c/p\u003e\u003cp\u003eThe following workarounds are recommended to help reduce the risk:\u003c/p\u003e\u003cul\u003e\u003cli\u003eUse prepared statements to help prevent SQL injections.\u003c/li\u003e\u003cli\u003eAvoid making assets publicly accessible.\u003c/li\u003e\u003cli\u003eRestrict public access: As a primary mitigation, it is crucial for all PnPSCADA users to avoid exposing their SCADA systems to the internet. By implementing proper network segmentation and isolating the SCADA system from public networks, users can significantly reduce the risk of unauthorized access and exploitation.\u003c/li\u003e\u003cli\u003eImplement strong access controls: Ensure that proper authentication and authorization mechanisms are in place to limit access to sensitive components of the SCADA system. This includes implementing role-based access control and regular audits of user privileges.\u003c/li\u003e\u003cli\u003eMonitor and log activity: Continuously monitor and log all activities within the SCADA environment. This helps with detecting any potential unauthorized access or attempts to exploit the vulnerability, enabling timely response and mitigation.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "SDG PnpSCADA is aware of the issue and is currently developing a fix. For more information, contact PnpSCADA by email.\n\nThe following workarounds are recommended to help reduce the risk:\n\n * Use prepared statements to help prevent SQL injections.\n * Avoid making assets publicly accessible.\n * Restrict public access: As a primary mitigation, it is crucial for all PnPSCADA users to avoid exposing their SCADA systems to the internet. By implementing proper network segmentation and isolating the SCADA system from public networks, users can significantly reduce the risk of unauthorized access and exploitation.\n * Implement strong access controls: Ensure that proper authentication and authorization mechanisms are in place to limit access to sensitive components of the SCADA system. This includes implementing role-based access control and regular audits of user privileges.\n * Monitor and log activity: Continuously monitor and log all activities within the SCADA environment. This helps with detecting any potential unauthorized access or attempts to exploit the vulnerability, enabling timely response and mitigation."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-1934",
"datePublished": "2023-05-12T13:18:25.512Z",
"dateReserved": "2023-04-06T23:59:34.451Z",
"dateUpdated": "2025-02-13T16:39:43.283Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-24841 (GCVE-0-2020-24841)
Vulnerability from cvelistv5 – Published: 2021-02-16 12:25 – Updated: 2026-07-09 00:11- n/a
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2026-07-09T00:11:02.079Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/48757"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "PNPSCADA 2.200816204020 allows SQL injection via parameter \u0027interf\u0027 in /browse.jsp. Exploiting this issue could allow an attacker to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-04T23:54:38.692Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.exploit-db.com/exploits/48757"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-24841",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "PNPSCADA 2.200816204020 allows SQL injection via parameter \u0027interf\u0027 in /browse.jsp. Exploiting this issue could allow an attacker to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://sdg.com",
"refsource": "MISC",
"url": "http://sdg.com"
},
{
"name": "https://www.exploit-db.com/exploits/48757",
"refsource": "MISC",
"url": "https://www.exploit-db.com/exploits/48757"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-24841",
"datePublished": "2021-02-16T12:25:39.000Z",
"dateReserved": "2020-08-28T00:00:00.000Z",
"dateUpdated": "2026-07-09T00:11:02.079Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}