    CVE-2018-8840 (GCVE-0-2018-8840)

    Vulnerability from cvelistv5 – Published: 2018-04-18 20:00 – Updated: 2024-09-16 17:53
    VLAI
    Summary
    A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
    Assigner
    Impacted products
    Vendor Product Version
    ICS-CERT Schneider Electric InduSoft Web Studio and InTouch Machine Edition Affected: InduSoft Web Studio v8.1 and prior versions, and InTouch Machine Edition 2017 v8.1 and prior versions.
    Create a notification for this product.
    Date Public
    2018-04-06 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:02:26.247Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "103949",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/103949"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2018-07"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Schneider Electric InduSoft Web Studio and InTouch Machine Edition",
              "vendor": "ICS-CERT",
              "versions": [
                {
                  "status": "affected",
                  "version": "InduSoft Web Studio v8.1 and prior versions, and InTouch Machine Edition 2017 v8.1 and prior versions."
                }
              ]
            }
          ],
          "datePublic": "2018-04-06T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-04-24T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "103949",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/103949"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2018-07"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-04-06T00:00:00",
              "ID": "CVE-2018-8840",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Schneider Electric InduSoft Web Studio and InTouch Machine Edition",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "InduSoft Web Studio v8.1 and prior versions, and InTouch Machine Edition 2017 v8.1 and prior versions."
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ICS-CERT"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "103949",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/103949"
                },
                {
                  "name": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/",
                  "refsource": "MISC",
                  "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2018-07",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2018-07"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-8840",
        "datePublished": "2018-04-18T20:00:00.000Z",
        "dateReserved": "2018-03-20T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:53:19.851Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }