CVE-2021-36385 (GCVE-0-2021-36385)
Vulnerability from cvelistv5 – Published: 2021-08-24 11:26 – Updated: 2024-08-04 00:54
VLAI
Summary
A SQL Injection vulnerability in Cerner Mobile Care 5.0.0 allows remote unauthenticated attackers to execute arbitrary SQL commands via a Fullwidth Apostrophe (aka U+FF07) in the default.aspx User ID field. Arbitrary system commands can be executed through the use of xp_cmdshell.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.blacklanternsecurity.com/blog/ | x_refsource_MISC |
| https://www.cerner.com/solutions/mobility | x_refsource_MISC |
| https://www.blacklanternsecurity.com/2021-08-13-C… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:54:51.475Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.blacklanternsecurity.com/blog/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cerner.com/solutions/mobility"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.blacklanternsecurity.com/2021-08-13-Cerner-MobileCare-CVE/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A SQL Injection vulnerability in Cerner Mobile Care 5.0.0 allows remote unauthenticated attackers to execute arbitrary SQL commands via a Fullwidth Apostrophe (aka U+FF07) in the default.aspx User ID field. Arbitrary system commands can be executed through the use of xp_cmdshell."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-24T11:26:14.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.blacklanternsecurity.com/blog/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cerner.com/solutions/mobility"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.blacklanternsecurity.com/2021-08-13-Cerner-MobileCare-CVE/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-36385",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A SQL Injection vulnerability in Cerner Mobile Care 5.0.0 allows remote unauthenticated attackers to execute arbitrary SQL commands via a Fullwidth Apostrophe (aka U+FF07) in the default.aspx User ID field. Arbitrary system commands can be executed through the use of xp_cmdshell."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.blacklanternsecurity.com/blog/",
"refsource": "MISC",
"url": "https://www.blacklanternsecurity.com/blog/"
},
{
"name": "https://www.cerner.com/solutions/mobility",
"refsource": "MISC",
"url": "https://www.cerner.com/solutions/mobility"
},
{
"name": "https://www.blacklanternsecurity.com/2021-08-13-Cerner-MobileCare-CVE/",
"refsource": "MISC",
"url": "https://www.blacklanternsecurity.com/2021-08-13-Cerner-MobileCare-CVE/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-36385",
"datePublished": "2021-08-24T11:26:14.000Z",
"dateReserved": "2021-07-12T00:00:00.000Z",
"dateUpdated": "2024-08-04T00:54:51.475Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-11677 (GCVE-0-2020-11677)
Vulnerability from cvelistv5 – Published: 2020-04-29 13:54 – Updated: 2024-08-04 11:35
VLAI
Summary
Cerner medico 26.00 has a Local Buffer Overflow (issue 3 of 3).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.x41-dsec.de/lab/advisories/x41-2019-0… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:35:13.769Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cerner medico 26.00 has a Local Buffer Overflow (issue 3 of 3)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-29T13:54:54.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-11677",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cerner medico 26.00 has a Local Buffer Overflow (issue 3 of 3)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/",
"refsource": "MISC",
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-11677",
"datePublished": "2020-04-29T13:54:54.000Z",
"dateReserved": "2020-04-10T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:35:13.769Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-11676 (GCVE-0-2020-11676)
Vulnerability from cvelistv5 – Published: 2020-04-29 13:53 – Updated: 2024-08-04 11:35
VLAI
Summary
Cerner medico 26.00 has a Local Buffer Overflow (issue 2 of 3).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.x41-dsec.de/lab/advisories/x41-2019-0… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:35:13.705Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cerner medico 26.00 has a Local Buffer Overflow (issue 2 of 3)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-29T13:53:34.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-11676",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cerner medico 26.00 has a Local Buffer Overflow (issue 2 of 3)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/",
"refsource": "MISC",
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-11676",
"datePublished": "2020-04-29T13:53:34.000Z",
"dateReserved": "2020-04-10T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:35:13.705Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-11675 (GCVE-0-2020-11675)
Vulnerability from cvelistv5 – Published: 2020-04-29 13:51 – Updated: 2024-08-04 11:35
VLAI
Summary
Cerner medico 26.00 has a Local Buffer Overflow (issue 1 of 3).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.x41-dsec.de/lab/advisories/x41-2019-0… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:35:13.711Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cerner medico 26.00 has a Local Buffer Overflow (issue 1 of 3)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-29T13:51:49.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-11675",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cerner medico 26.00 has a Local Buffer Overflow (issue 1 of 3)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/",
"refsource": "MISC",
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-11675",
"datePublished": "2020-04-29T13:51:49.000Z",
"dateReserved": "2020-04-10T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:35:13.711Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-11674 (GCVE-0-2020-11674)
Vulnerability from cvelistv5 – Published: 2020-04-29 13:50 – Updated: 2024-08-04 11:35
VLAI
Summary
Cerner medico 26.00 allows variable reuse, possibly causing data corruption.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.x41-dsec.de/lab/advisories/x41-2019-0… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:35:13.640Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cerner medico 26.00 allows variable reuse, possibly causing data corruption."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-29T13:50:09.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-11674",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cerner medico 26.00 allows variable reuse, possibly causing data corruption."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/",
"refsource": "MISC",
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-11674",
"datePublished": "2020-04-29T13:50:09.000Z",
"dateReserved": "2020-04-10T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:35:13.640Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-36385 (GCVE-0-2021-36385)
Vulnerability from nvd – Published: 2021-08-24 11:26 – Updated: 2024-08-04 00:54
VLAI
Summary
A SQL Injection vulnerability in Cerner Mobile Care 5.0.0 allows remote unauthenticated attackers to execute arbitrary SQL commands via a Fullwidth Apostrophe (aka U+FF07) in the default.aspx User ID field. Arbitrary system commands can be executed through the use of xp_cmdshell.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.blacklanternsecurity.com/blog/ | x_refsource_MISC |
| https://www.cerner.com/solutions/mobility | x_refsource_MISC |
| https://www.blacklanternsecurity.com/2021-08-13-C… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:54:51.475Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.blacklanternsecurity.com/blog/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cerner.com/solutions/mobility"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.blacklanternsecurity.com/2021-08-13-Cerner-MobileCare-CVE/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A SQL Injection vulnerability in Cerner Mobile Care 5.0.0 allows remote unauthenticated attackers to execute arbitrary SQL commands via a Fullwidth Apostrophe (aka U+FF07) in the default.aspx User ID field. Arbitrary system commands can be executed through the use of xp_cmdshell."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-24T11:26:14.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.blacklanternsecurity.com/blog/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cerner.com/solutions/mobility"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.blacklanternsecurity.com/2021-08-13-Cerner-MobileCare-CVE/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-36385",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A SQL Injection vulnerability in Cerner Mobile Care 5.0.0 allows remote unauthenticated attackers to execute arbitrary SQL commands via a Fullwidth Apostrophe (aka U+FF07) in the default.aspx User ID field. Arbitrary system commands can be executed through the use of xp_cmdshell."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.blacklanternsecurity.com/blog/",
"refsource": "MISC",
"url": "https://www.blacklanternsecurity.com/blog/"
},
{
"name": "https://www.cerner.com/solutions/mobility",
"refsource": "MISC",
"url": "https://www.cerner.com/solutions/mobility"
},
{
"name": "https://www.blacklanternsecurity.com/2021-08-13-Cerner-MobileCare-CVE/",
"refsource": "MISC",
"url": "https://www.blacklanternsecurity.com/2021-08-13-Cerner-MobileCare-CVE/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-36385",
"datePublished": "2021-08-24T11:26:14.000Z",
"dateReserved": "2021-07-12T00:00:00.000Z",
"dateUpdated": "2024-08-04T00:54:51.475Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-11677 (GCVE-0-2020-11677)
Vulnerability from nvd – Published: 2020-04-29 13:54 – Updated: 2024-08-04 11:35
VLAI
Summary
Cerner medico 26.00 has a Local Buffer Overflow (issue 3 of 3).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.x41-dsec.de/lab/advisories/x41-2019-0… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:35:13.769Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cerner medico 26.00 has a Local Buffer Overflow (issue 3 of 3)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-29T13:54:54.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-11677",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cerner medico 26.00 has a Local Buffer Overflow (issue 3 of 3)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/",
"refsource": "MISC",
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-11677",
"datePublished": "2020-04-29T13:54:54.000Z",
"dateReserved": "2020-04-10T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:35:13.769Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-11676 (GCVE-0-2020-11676)
Vulnerability from nvd – Published: 2020-04-29 13:53 – Updated: 2024-08-04 11:35
VLAI
Summary
Cerner medico 26.00 has a Local Buffer Overflow (issue 2 of 3).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.x41-dsec.de/lab/advisories/x41-2019-0… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:35:13.705Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cerner medico 26.00 has a Local Buffer Overflow (issue 2 of 3)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-29T13:53:34.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-11676",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cerner medico 26.00 has a Local Buffer Overflow (issue 2 of 3)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/",
"refsource": "MISC",
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-11676",
"datePublished": "2020-04-29T13:53:34.000Z",
"dateReserved": "2020-04-10T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:35:13.705Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-11675 (GCVE-0-2020-11675)
Vulnerability from nvd – Published: 2020-04-29 13:51 – Updated: 2024-08-04 11:35
VLAI
Summary
Cerner medico 26.00 has a Local Buffer Overflow (issue 1 of 3).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.x41-dsec.de/lab/advisories/x41-2019-0… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:35:13.711Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cerner medico 26.00 has a Local Buffer Overflow (issue 1 of 3)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-29T13:51:49.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-11675",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cerner medico 26.00 has a Local Buffer Overflow (issue 1 of 3)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/",
"refsource": "MISC",
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-11675",
"datePublished": "2020-04-29T13:51:49.000Z",
"dateReserved": "2020-04-10T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:35:13.711Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-11674 (GCVE-0-2020-11674)
Vulnerability from nvd – Published: 2020-04-29 13:50 – Updated: 2024-08-04 11:35
VLAI
Summary
Cerner medico 26.00 allows variable reuse, possibly causing data corruption.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.x41-dsec.de/lab/advisories/x41-2019-0… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:35:13.640Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cerner medico 26.00 allows variable reuse, possibly causing data corruption."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-29T13:50:09.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-11674",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cerner medico 26.00 allows variable reuse, possibly causing data corruption."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/",
"refsource": "MISC",
"url": "https://www.x41-dsec.de/lab/advisories/x41-2019-008-medico/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-11674",
"datePublished": "2020-04-29T13:50:09.000Z",
"dateReserved": "2020-04-10T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:35:13.640Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}