Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    40 vulnerabilities by barco

    VAR-201912-0691

    Vulnerability from variot - Updated: 2024-02-13 22:58

    Barco ClickShare Button R9861500D01 devices before 1.10.0.13 have Missing Support for Integrity Check. The ClickShare Button does not verify the integrity of the mutable content on the UBIFS partition before being used. Barco ClickShare Button R9861500D01 The device contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. An attacker can use this vulnerability to open a backdoor to the device and present specially crafted data to the user

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201912-0691",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare button r9861500d01",
            "scope": "lt",
            "trust": 1.4,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare button r9861500d01",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.10.0.13"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22807"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013448"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18824"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_button_r9861500d01_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.10.0.13",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_button_r9861500d01:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18824"
          }
        ]
      },
      "cve": "CVE-2019-18824",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.9,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.4,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": true,
                "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Local",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 6.9,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2019-18824",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.9,
                "userInteractionRequired": null,
                "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2020-22807",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 6.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.7,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Physical",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.6,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-18824",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-18824",
                "trust": 1.8,
                "value": "MEDIUM"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2020-22807",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201912-771",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2019-18824",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22807"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-18824"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013448"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-771"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18824"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 devices before 1.10.0.13 have Missing Support for Integrity Check. The ClickShare Button does not verify the integrity of the mutable content on the UBIFS partition before being used. Barco ClickShare Button R9861500D01 The device contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. An attacker can use this vulnerability to open a backdoor to the device and present specially crafted data to the user",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18824"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013448"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-22807"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-18824"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-18824",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013448",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-22807",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-771",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-18824",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22807"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-18824"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013448"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-771"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18824"
          }
        ]
      },
      "id": "VAR-201912-0691",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22807"
          }
        ],
        "trust": 1.3368421000000001
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22807"
          }
        ]
      },
      "last_update_date": "2024-02-13T22:58:47.432000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Update your ClickShare device",
            "trust": 0.8,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "title": "Patch for Barco ClickShare Button R9861500D01 Input Verification Error Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/213745"
          },
          {
            "title": "Barco ClickShare Button R9861500D01 Enter the fix for the verification error vulnerability",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105916"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22807"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013448"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-771"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-345",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-20",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013448"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18824"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
          },
          {
            "trust": 2.3,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "trust": 1.7,
            "url": "https://www.barco.com/en/clickshare/support/software/r33050070?majorversion=01\u0026minorversion=10\u0026patchversion=00\u0026buildversion=013"
          },
          {
            "trust": 1.7,
            "url": "https://www.barco.com/en/clickshare/support/software/r33050069?majorversion=01\u0026minorversion=10\u0026patchversion=00\u0026buildversion=013"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-18824"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18824"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/345.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22807"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-18824"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013448"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-771"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18824"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22807"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-18824"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013448"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-771"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18824"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-04-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-22807"
          },
          {
            "date": "2019-12-17T00:00:00",
            "db": "VULMON",
            "id": "CVE-2019-18824"
          },
          {
            "date": "2020-01-07T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013448"
          },
          {
            "date": "2019-12-17T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-771"
          },
          {
            "date": "2019-12-17T14:15:17.747000",
            "db": "NVD",
            "id": "CVE-2019-18824"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-04-14T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-22807"
          },
          {
            "date": "2021-07-21T00:00:00",
            "db": "VULMON",
            "id": "CVE-2019-18824"
          },
          {
            "date": "2020-01-07T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013448"
          },
          {
            "date": "2020-08-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-771"
          },
          {
            "date": "2021-07-21T11:39:23.747000",
            "db": "NVD",
            "id": "CVE-2019-18824"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 Vulnerability related to input validation on devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013448"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "input validation error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-771"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201912-0693

    Vulnerability from variot - Updated: 2023-12-18 13:38

    Barco ClickShare Button R9861500D01 devices before 1.9.0 have Improper Following of a Certificate's Chain of Trust. The embedded 'dongle_bridge' program used to expose the functionalities of the ClickShare Button to a USB host, does not properly validate the whole certificate chain. Barco ClickShare Button R9861500D01 The device contains a certificate validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Attackers can use this vulnerability to authenticate and gain access to restricted commands

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201912-0693",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare cs-100",
            "scope": "lt",
            "trust": 1.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200",
            "scope": "lt",
            "trust": 1.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-800",
            "scope": "lt",
            "trust": 1.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 1.2,
            "vendor": "barco",
            "version": null
          },
          {
            "model": "clickshare cse-200\\+",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200+",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare button r9861500d01",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.1.0.99"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.2.1.6"
          },
          {
            "model": "clickshare cse-200",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": null
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.8.2.2"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.7.0.22"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.6.4.4"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.2.0.47"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.7.1.1"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46447"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013803"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18826"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-724"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cs-100_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cs-100:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200\\+_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200\\+:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-800_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-800:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18826"
          }
        ]
      },
      "cve": "CVE-2019-18826",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 7.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2019-18826",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 6.4,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-46447",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-18826",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-18826",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-46447",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201912-724",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46447"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013803"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18826"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-724"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 devices before 1.9.0 have Improper Following of a Certificate\u0027s Chain of Trust. The embedded \u0027dongle_bridge\u0027 program used to expose the functionalities of the ClickShare Button to a USB host, does not properly validate the whole certificate chain. Barco ClickShare Button R9861500D01 The device contains a certificate validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Attackers can use this vulnerability to authenticate and gain access to restricted commands ",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18826"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013803"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-46447"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-18826",
            "trust": 3.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013803",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-46447",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-724",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46447"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013803"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18826"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-724"
          }
        ]
      },
      "id": "VAR-201912-0693",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46447"
          }
        ],
        "trust": 1.3368421000000001
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46447"
          }
        ]
      },
      "last_update_date": "2023-12-18T13:38:03.652000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Update your ClickShare device",
            "trust": 0.8,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "title": "Patch for Barco ClickShare Button R9861500D01 Validation Error Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/194979"
          },
          {
            "title": "Barco ClickShare Button R9861500D01 Repair measures for trust management problem vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105991"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46447"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013803"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-724"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-295",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013803"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18826"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.2,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-18826"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18826"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46447"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013803"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18826"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-724"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46447"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013803"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18826"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-724"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-12-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-46447"
          },
          {
            "date": "2020-01-16T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013803"
          },
          {
            "date": "2019-12-16T17:15:11.877000",
            "db": "NVD",
            "id": "CVE-2019-18826"
          },
          {
            "date": "2019-12-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-724"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-12-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-46447"
          },
          {
            "date": "2020-01-16T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013803"
          },
          {
            "date": "2019-12-27T01:14:58.913000",
            "db": "NVD",
            "id": "CVE-2019-18826"
          },
          {
            "date": "2019-12-30T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-724"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-724"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 Device validation vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013803"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "trust management problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-724"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201710-1335

    Vulnerability from variot - Updated: 2023-12-18 13:24

    A command injection was identified on Barco ClickShare Base Unit devices with CSM-1 firmware before 1.7.0.3 and CSC-1 firmware before 1.10.0.10. An attacker with access to the product's web API can exploit this vulnerability to completely compromise the vulnerable device. BarcoClickShareCSM-1BaseUnit and ClickShareCSC-1BaseUnit are both wireless presentation system host devices from Barco, Belgium. Multiple Barco ClickShare Base Units are prone to multiple command-injection vulnerabilities because it fails to properly sanitize user-supplied input. This may aid in further attacks

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201710-1335",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare csc-1",
            "scope": "lt",
            "trust": 1.8,
            "vendor": "barco",
            "version": "1.10.0.10"
          },
          {
            "model": "clickshare csm-1",
            "scope": "lt",
            "trust": 1.8,
            "vendor": "barco",
            "version": "1.7.0.3"
          },
          {
            "model": "clickshare csm-1 base unit",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.7.0.3"
          },
          {
            "model": "clickshare csc-1 base unit",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.10.0.10"
          },
          {
            "model": "clickshare csm-1",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.6.4.1"
          },
          {
            "model": "clickshare csm-1",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.6.3.5"
          },
          {
            "model": "clickshare csc-1",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.9.5.2"
          },
          {
            "model": "clickshare csc-1",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.9.4.3"
          },
          {
            "model": "clickshare csm-1",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.7.0.3"
          },
          {
            "model": "clickshare csc-1",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.10.0.10"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-33051"
          },
          {
            "db": "BID",
            "id": "101617"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009832"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9377"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_csm-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.7.0.3",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_csm-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_csc-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.10.0.10",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_csc-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-9377"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Claudio Moletta",
        "sources": [
          {
            "db": "BID",
            "id": "101617"
          }
        ],
        "trust": 0.3
      },
      "cve": "CVE-2017-9377",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 9.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2017-9377",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.9,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2017-33051",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2017-9377",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2017-9377",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-33051",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201706-171",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2017-9377",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-33051"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-9377"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009832"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9377"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-171"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "A command injection was identified on Barco ClickShare Base Unit devices with CSM-1 firmware before 1.7.0.3 and CSC-1 firmware before 1.10.0.10. An attacker with access to the product\u0027s web API can exploit this vulnerability to completely compromise the vulnerable device. BarcoClickShareCSM-1BaseUnit and ClickShareCSC-1BaseUnit are both wireless presentation system host devices from Barco, Belgium. Multiple Barco ClickShare Base Units are prone to multiple command-injection vulnerabilities because it fails to properly sanitize user-supplied input. This may aid in further   attacks",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-9377"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009832"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-33051"
          },
          {
            "db": "BID",
            "id": "101617"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-9377"
          }
        ],
        "trust": 2.52
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-9377",
            "trust": 3.4
          },
          {
            "db": "BID",
            "id": "101617",
            "trust": 2.6
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009832",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-33051",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-171",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-9377",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-33051"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-9377"
          },
          {
            "db": "BID",
            "id": "101617"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009832"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9377"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-171"
          }
        ]
      },
      "id": "VAR-201710-1335",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-33051"
          }
        ],
        "trust": 1.6
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-33051"
          }
        ]
      },
      "last_update_date": "2023-12-18T13:24:17.942000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "ClickShare CSC-1 Base Unit Firmware v1.10.0.10",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050020"
          },
          {
            "title": "ClickShare CSM-1 Base Unit Firmware v1.7.0.3",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050037"
          },
          {
            "title": "Patch for BarcoClickShareCSM-1BaseUnit and ClickShareCSC-1BaseUnit command injection vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/105610"
          },
          {
            "title": "Barco ClickShare CSM-1 Base Unit  and ClickShare CSC-1 Base Unit Fixes for command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=99842"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-33051"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009832"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-171"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-77",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009832"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9377"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "https://www.barco.com/en/support/software/r33050020"
          },
          {
            "trust": 2.0,
            "url": "https://www.barco.com/en/support/software/r33050037"
          },
          {
            "trust": 2.0,
            "url": "https://www.contextis.com/resources/advisories/cve-2017-9377"
          },
          {
            "trust": 1.8,
            "url": "http://www.securityfocus.com/bid/101617"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9377"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9377"
          },
          {
            "trust": 0.3,
            "url": "https://www.barco.com/en/clickshare"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/78.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-33051"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-9377"
          },
          {
            "db": "BID",
            "id": "101617"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009832"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9377"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-171"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-33051"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-9377"
          },
          {
            "db": "BID",
            "id": "101617"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009832"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-9377"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-171"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-11-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-33051"
          },
          {
            "date": "2017-10-30T00:00:00",
            "db": "VULMON",
            "id": "CVE-2017-9377"
          },
          {
            "date": "2017-09-27T00:00:00",
            "db": "BID",
            "id": "101617"
          },
          {
            "date": "2017-11-24T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-009832"
          },
          {
            "date": "2017-10-30T14:29:00.923000",
            "db": "NVD",
            "id": "CVE-2017-9377"
          },
          {
            "date": "2017-06-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-171"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-11-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-33051"
          },
          {
            "date": "2019-10-03T00:00:00",
            "db": "VULMON",
            "id": "CVE-2017-9377"
          },
          {
            "date": "2017-12-19T21:00:00",
            "db": "BID",
            "id": "101617"
          },
          {
            "date": "2017-11-24T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-009832"
          },
          {
            "date": "2019-10-03T00:03:26.223000",
            "db": "NVD",
            "id": "CVE-2017-9377"
          },
          {
            "date": "2019-10-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201706-171"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-171"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare CSM-1 Base Unit and ClickShare CSC-1 Base Unit Command Injection Vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-33051"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-171"
          }
        ],
        "trust": 1.2
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201706-171"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201912-0684

    Vulnerability from variot - Updated: 2023-12-18 13:07

    Barco ClickShare Button R9861500D01 devices before 1.9.0 allow Information exposure (issue 2 of 2).. The encryption key of the media content which is shared between a ClickShare Button and a ClickShare Base Unit is randomly generated for each new session and communicated over a TLS connection. An attacker who is able to perform a Man-in-the-Middle attack between the TLS connection, is able to obtain the encryption key. Barco ClickShare Button R9861500D01 The device contains a vulnerability related to the lack of encryption of critical data.Information may be obtained. Barco ClickShare Button R9861500D01 is a wireless control device for the demonstration system of Barco, Belgium

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201912-0684",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare button r9861500d01",
            "scope": "lt",
            "trust": 2.4,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare button r9861500d01",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46252"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013452"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18833"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-776"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_button_r9861500d01_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_button_r9861500d01:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18833"
          }
        ]
      },
      "cve": "CVE-2019-18833",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.3,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2019-18833",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-46252",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.2,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "High",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.9,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-18833",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-18833",
                "trust": 1.8,
                "value": "MEDIUM"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-46252",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201912-776",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46252"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013452"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18833"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-776"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 devices before 1.9.0 allow Information exposure (issue 2 of 2).. The encryption key of the media content which is shared between a ClickShare Button and a ClickShare Base Unit is randomly generated for each new session and communicated over a TLS connection. An attacker who is able to perform a Man-in-the-Middle attack between the TLS connection, is able to obtain the encryption key. Barco ClickShare Button R9861500D01 The device contains a vulnerability related to the lack of encryption of critical data.Information may be obtained. Barco ClickShare Button R9861500D01 is a wireless control device for the demonstration system of Barco, Belgium",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18833"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013452"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-46252"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-18833",
            "trust": 3.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013452",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-46252",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-776",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46252"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013452"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18833"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-776"
          }
        ]
      },
      "id": "VAR-201912-0684",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46252"
          }
        ],
        "trust": 1.3368421000000001
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46252"
          }
        ]
      },
      "last_update_date": "2023-12-18T13:07:48.389000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Update your ClickShare device",
            "trust": 0.8,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "title": "Patch for Barco ClickShare Button R9861500D01 Key Disclosure Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/194663"
          },
          {
            "title": "Barco ClickShare Button R9861500D01 Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105920"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46252"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013452"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-776"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-311",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013452"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18833"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
          },
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-18833"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18833"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46252"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013452"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18833"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-776"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46252"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013452"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18833"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-776"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-12-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-46252"
          },
          {
            "date": "2020-01-07T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013452"
          },
          {
            "date": "2019-12-17T14:15:18.030000",
            "db": "NVD",
            "id": "CVE-2019-18833"
          },
          {
            "date": "2019-12-17T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-776"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-12-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-46252"
          },
          {
            "date": "2020-01-07T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013452"
          },
          {
            "date": "2019-12-26T15:24:20.467000",
            "db": "NVD",
            "id": "CVE-2019-18833"
          },
          {
            "date": "2019-12-27T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-776"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-776"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 Vulnerability related to lack of encryption of critical data on devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013452"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-201912-0680

    Vulnerability from variot - Updated: 2023-12-18 13:01

    Barco ClickShare Button R9861500D01 devices before 1.10.0.13 have Missing Support for Integrity Check. The Barco signed 'Clickshare_For_Windows.exe' binary on the ClickShare Button (R9861500D01) loads a number of DLL files dynamically without verifying their integrity. Barco ClickShare Button R9861500D01 The device contains an untrusted search path vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Attackers can use this vulnerability to inject arbitrary code

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201912-0680",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare button r9861500d01",
            "scope": "lt",
            "trust": 1.4,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare button r9861500d01",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.10.0.13"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22684"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013450"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18829"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_button_r9861500d01_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.10.0.13",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_button_r9861500d01:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18829"
          }
        ]
      },
      "cve": "CVE-2019-18829",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.4,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.4,
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": true,
                "vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Local",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 4.4,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2019-18829",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2020-22684",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.8,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-18829",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-18829",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2020-22684",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201912-773",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22684"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013450"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18829"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-773"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 devices before 1.10.0.13 have Missing Support for Integrity Check. The Barco signed \u0027Clickshare_For_Windows.exe\u0027 binary on the ClickShare Button (R9861500D01) loads a number of DLL files dynamically without verifying their integrity. Barco ClickShare Button R9861500D01 The device contains an untrusted search path vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Attackers can use this vulnerability to inject arbitrary code",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18829"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013450"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-22684"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-18829",
            "trust": 3.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013450",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-22684",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-773",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22684"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013450"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18829"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-773"
          }
        ]
      },
      "id": "VAR-201912-0680",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22684"
          }
        ],
        "trust": 1.3368421000000001
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22684"
          }
        ]
      },
      "last_update_date": "2023-12-18T13:01:57.457000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Update your ClickShare device",
            "trust": 0.8,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "title": "Patch for Barco ClickShare Button R9861500D01 code issue vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/213719"
          },
          {
            "title": "Barco ClickShare Button R9861500D01 Fixes for code issue vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105918"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22684"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013450"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-773"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-345",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-426",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013450"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18829"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
          },
          {
            "trust": 2.2,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/clickshare/support/software/r33050069?majorversion=01\u0026minorversion=10\u0026patchversion=00\u0026buildversion=013"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/clickshare/support/software/r33050070?majorversion=01\u0026minorversion=10\u0026patchversion=00\u0026buildversion=013"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-18829"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18829"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22684"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013450"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18829"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-773"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-22684"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013450"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18829"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-773"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-04-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-22684"
          },
          {
            "date": "2020-01-07T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013450"
          },
          {
            "date": "2019-12-17T14:15:17.903000",
            "db": "NVD",
            "id": "CVE-2019-18829"
          },
          {
            "date": "2019-12-17T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-773"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-04-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-22684"
          },
          {
            "date": "2020-01-07T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013450"
          },
          {
            "date": "2021-07-21T11:39:23.747000",
            "db": "NVD",
            "id": "CVE-2019-18829"
          },
          {
            "date": "2020-08-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-773"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-773"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 Unreliable search path vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013450"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "code problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-773"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201912-0682

    Vulnerability from variot - Updated: 2023-12-18 12:56

    Barco ClickShare Button R9861500D01 devices before 1.9.0 allow Information Exposure. The encrypted ClickShare Button firmware contains the private key of a test device-certificate. Attackers can use this vulnerability to disclose information

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201912-0682",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare cse-200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200\\+",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-800",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cs-100",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cs-100",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200+",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare button r9861500d01",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.9.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46448"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013420"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18831"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cs-100_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cs-100:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200\\+_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200\\+:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-800_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-800:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18831"
          }
        ]
      },
      "cve": "CVE-2019-18831",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.8,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "LOW",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:M/Au:S/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 3.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2019-18831",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Low",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:M/Au:S/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-46448",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.6,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "High",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.3,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-18831",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-18831",
                "trust": 1.8,
                "value": "MEDIUM"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-46448",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201912-726",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46448"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013420"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18831"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-726"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 devices before 1.9.0 allow Information Exposure. The encrypted ClickShare Button firmware contains the private key of a test device-certificate. Attackers can use this vulnerability to disclose information",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18831"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013420"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-46448"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-18831",
            "trust": 3.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013420",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-46448",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-726",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46448"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013420"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18831"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-726"
          }
        ]
      },
      "id": "VAR-201912-0682",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46448"
          }
        ],
        "trust": 1.3368421000000001
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46448"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:56:18.506000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "ClickShare",
            "trust": 0.8,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "title": "ClickShare CS-100 base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "ClickShare CSE-200 base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "ClickShare CSE-800 base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "ClickShare CSE-200+ base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "Patch for Barco ClickShare Button R9861500D01 Information Disclosure Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/194985"
          },
          {
            "title": "Barco ClickShare Button R9861500D01 Repair measures for information disclosure vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105749"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46448"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013420"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-726"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-798",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-200",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013420"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18831"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.2,
            "url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
          },
          {
            "trust": 2.2,
            "url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-18831"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18831"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46448"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013420"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18831"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-726"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46448"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013420"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18831"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-726"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-12-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-46448"
          },
          {
            "date": "2019-12-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013420"
          },
          {
            "date": "2019-12-16T17:15:12.177000",
            "db": "NVD",
            "id": "CVE-2019-18831"
          },
          {
            "date": "2019-12-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-726"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-12-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-46448"
          },
          {
            "date": "2019-12-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013420"
          },
          {
            "date": "2020-08-24T17:37:01.140000",
            "db": "NVD",
            "id": "CVE-2019-18831"
          },
          {
            "date": "2020-08-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-726"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-726"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button Information disclosure vulnerability in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013420"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "trust management problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-726"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201912-0681

    Vulnerability from variot - Updated: 2023-12-18 12:35

    Barco ClickShare Button R9861500D01 devices before 1.9.0 allow OS Command Injection. The embedded 'dongle_bridge' program used to expose the functionalities of the ClickShare Button to a USB host, is vulnerable to OS command injection vulnerabilities. These vulnerabilities could lead to code execution on the ClickShare Button with the privileges of the user 'nobody'. Barco ClickShare Button The device includes OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Barco ClickShare Button R9861500D01 is a wireless control device for the demonstration system of Barco, Belgium.

    Barco ClickShare Button R9861500D01 The Dongle_bridge program embedded in versions earlier than 1.9.0 has an operating system command injection vulnerability, which originates from the process of externally inputting data to construct operating system executable commands, and the network system or product did not properly filter the special characters and commands. The attacker can use this vulnerability to execute illegal operating system commands

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201912-0681",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare cse-200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200\\+",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-800",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cs-100",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cs-100",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200+",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare button r9861500d01",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.9.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46446"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013419"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18830"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cs-100_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cs-100:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200\\+_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200\\+:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-800_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-800:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18830"
          }
        ]
      },
      "cve": "CVE-2019-18830",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 10.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2019-18830",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.9,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-46446",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-18830",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-18830",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-46446",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201912-720",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULMON",
                "id": "CVE-2019-18830",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46446"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-18830"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013419"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18830"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-720"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 devices before 1.9.0 allow OS Command Injection. The embedded \u0027dongle_bridge\u0027 program used to expose the functionalities of the ClickShare Button to a USB host, is vulnerable to OS command injection vulnerabilities. These vulnerabilities could lead to code execution on the ClickShare Button with the privileges of the user \u0027nobody\u0027. Barco ClickShare Button The device includes OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Barco ClickShare Button R9861500D01 is a wireless control device for the demonstration system of Barco, Belgium. \n\nBarco ClickShare Button R9861500D01 The Dongle_bridge program embedded in versions earlier than 1.9.0 has an operating system command injection vulnerability, which originates from the process of externally inputting data to construct operating system executable commands, and the network system or product did not properly filter the special characters and commands. The attacker can use this vulnerability to execute illegal operating system commands",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18830"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013419"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-46446"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-18830"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-18830",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013419",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-46446",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-720",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-18830",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46446"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-18830"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013419"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18830"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-720"
          }
        ]
      },
      "id": "VAR-201912-0681",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46446"
          }
        ],
        "trust": 1.3368421000000001
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46446"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:35:53.659000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "ClickShare",
            "trust": 0.8,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "title": "ClickShare CS-100 base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "ClickShare CSE-200 base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "ClickShare CSE-800 base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "ClickShare CSE-200+ base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "Patch for Barco ClickShare Button R9861500D01 Operating System Command Injection Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/194973"
          },
          {
            "title": "Barco ClickShare Button R9861500D01 Fixes for operating system command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105748"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46446"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013419"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-720"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013419"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18830"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.3,
            "url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-18830"
          },
          {
            "trust": 1.7,
            "url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 1.7,
            "url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
          },
          {
            "trust": 1.7,
            "url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 1.7,
            "url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 1.7,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18830"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/78.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46446"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-18830"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013419"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18830"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-720"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46446"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-18830"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013419"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18830"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-720"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-12-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-46446"
          },
          {
            "date": "2019-12-16T00:00:00",
            "db": "VULMON",
            "id": "CVE-2019-18830"
          },
          {
            "date": "2019-12-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013419"
          },
          {
            "date": "2019-12-16T17:15:12.080000",
            "db": "NVD",
            "id": "CVE-2019-18830"
          },
          {
            "date": "2019-12-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-720"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-12-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-46446"
          },
          {
            "date": "2019-12-23T00:00:00",
            "db": "VULMON",
            "id": "CVE-2019-18830"
          },
          {
            "date": "2019-12-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013419"
          },
          {
            "date": "2019-12-23T18:11:44.480000",
            "db": "NVD",
            "id": "CVE-2019-18830"
          },
          {
            "date": "2020-06-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-720"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-720"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 Operating System Command Injection Vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46446"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-720"
          }
        ],
        "trust": 1.2
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-720"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201912-0683

    Vulnerability from variot - Updated: 2023-12-18 12:35

    Barco ClickShare Button R9861500D01 devices before 1.9.0 have incorrect Credentials Management. The ClickShare Button implements encryption at rest which uses a one-time programmable (OTP) AES encryption key. This key is shared across all ClickShare Buttons of model R9861500D01. Barco ClickShare Button R9861500D01 The device contains a vulnerability related to information disclosure from the cache.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Attackers could use this vulnerability to forge arbitrary software images

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201912-0683",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare button r9861500d01",
            "scope": "lt",
            "trust": 2.4,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare button r9861500d01",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-10435"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013451"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18832"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-775"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_button_r9861500d01_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_button_r9861500d01:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18832"
          }
        ]
      },
      "cve": "CVE-2019-18832",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 6.8,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2019-18832",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CNVD-2020-10435",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.2,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "High",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.1,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-18832",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-18832",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2020-10435",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201912-775",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-10435"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013451"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18832"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-775"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 devices before 1.9.0 have incorrect Credentials Management. The ClickShare Button implements encryption at rest which uses a one-time programmable (OTP) AES encryption key. This key is shared across all ClickShare Buttons of model R9861500D01. Barco ClickShare Button R9861500D01 The device contains a vulnerability related to information disclosure from the cache.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Attackers could use this vulnerability to forge arbitrary software images",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18832"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013451"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-10435"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-18832",
            "trust": 3.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013451",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-10435",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-775",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-10435"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013451"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18832"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-775"
          }
        ]
      },
      "id": "VAR-201912-0683",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-10435"
          }
        ],
        "trust": 1.3368421000000001
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "IoT"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-10435"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:35:53.633000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Update your ClickShare device",
            "trust": 0.8,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "title": "Patch for Barco ClickShare Button R9861500D01 Credential Management Error Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/201823"
          },
          {
            "title": "Barco ClickShare Button R9861500D01 Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105919"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-10435"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013451"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-775"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-327",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-522",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013451"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18832"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.0,
            "url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
          },
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-18832"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18832"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-10435"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013451"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18832"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-775"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-10435"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013451"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18832"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-775"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-02-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-10435"
          },
          {
            "date": "2020-01-07T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013451"
          },
          {
            "date": "2019-12-17T14:15:17.967000",
            "db": "NVD",
            "id": "CVE-2019-18832"
          },
          {
            "date": "2019-12-17T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-775"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-02-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-10435"
          },
          {
            "date": "2020-01-07T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013451"
          },
          {
            "date": "2021-07-21T11:39:23.747000",
            "db": "NVD",
            "id": "CVE-2019-18832"
          },
          {
            "date": "2019-12-27T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-775"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-775"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 Vulnerability related to information leak from cache in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013451"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-775"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201701-0402

    Vulnerability from variot - Updated: 2023-12-18 12:29

    Cross-site scripting (XSS) vulnerability in wallpaper.php in the Base Unit in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. Barco ClickShare is prone to a cross-site scripting vulnerability and a directory-traversal vulnerability because it fails to sufficiently sanitize user-supplied input. A remote attacker can leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site and to view arbitrary local files and directories within the context of the webserver. This may let the attacker steal cookie-based authentication credentials and gain access to sensitive information, which may aid in launching further attacks. Versions prior to Barco ClickShare 01.09.03, 01.06.02 and 01.03.02 are vulnerable. Barco ClickShare CSC-1 is a wireless presentation system from Barco, Belgium. Base Unit is one of the basic integration kits. The following devices are affected: Barco ClickShare CSC-1 devices with firmware prior to 01.09.03; CSM-1 devices with firmware prior to 01.06.02; CSE-200 devices with firmware prior to 01.03.02. A Path Traversal vulnerability exists within Barco ClickShare's wallpaper parsing functionality, which leads to disclosure of the /etc/shadow file on the file system.

    CVE-2016-3152 - /etc/shadow file disclosure in the CSC-1 firmware update Affected versions: all versions prior to v01.09.03 (CSC-1) It is possible to download and extract the firmware image of the CSC-1 and obtain the root password.

    The vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance.

    References: http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020&rev=001002000009 http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037&rev=001001000113 https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070&rev=001001000008

    --

    Regards,

    Vincent Ruijter Ethical Hacker Chief Information Security Office KPN B.V

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201701-0402",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare csc-1",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "barco",
            "version": "01.09.05.02"
          },
          {
            "model": "clickshare cse-200",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "barco",
            "version": "01.09.02.05"
          },
          {
            "model": "clickshare csc-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "barco",
            "version": null
          },
          {
            "model": "clickshare csc-1",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "barco",
            "version": "01.09.03"
          },
          {
            "model": "clickshare cse-200",
            "scope": null,
            "trust": 0.8,
            "vendor": "barco",
            "version": null
          },
          {
            "model": "clickshare cse-200",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "barco",
            "version": "01.03.02"
          },
          {
            "model": "clickshare csm-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "barco",
            "version": null
          },
          {
            "model": "clickshare csm-1",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "barco",
            "version": "01.06.02"
          },
          {
            "model": "clickshare csc-1",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "01.09.05.02"
          },
          {
            "model": "clickshare cse-200",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "01.09.02.05"
          },
          {
            "model": "clickshare",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.9.2"
          },
          {
            "model": "clickshare",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.6.1"
          },
          {
            "model": "clickshare",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.3.1"
          },
          {
            "model": "clickshare",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.9.3"
          },
          {
            "model": "clickshare",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.6.2"
          },
          {
            "model": "clickshare",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.3.2"
          }
        ],
        "sources": [
          {
            "db": "BID",
            "id": "94330"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006880"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3150"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-538"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_csc-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "01.09.05.02",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_csc-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "01.09.02.05",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2016-3150"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vincent Ruijter",
        "sources": [
          {
            "db": "BID",
            "id": "94330"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-538"
          }
        ],
        "trust": 1.0
      },
      "cve": "CVE-2016-3150",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 8.6,
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": true,
                "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.3,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2016-3150",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 8.6,
                "id": "VHN-91969",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.8,
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 6.1,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2016-3150",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "None",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2016-3150",
                "trust": 1.8,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201611-538",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-91969",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91969"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006880"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3150"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-538"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Cross-site scripting (XSS) vulnerability in wallpaper.php in the Base Unit in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. Barco ClickShare is prone to a cross-site scripting vulnerability and a directory-traversal vulnerability because it fails to sufficiently sanitize user-supplied input. \nA remote attacker can leverage these issues to execute arbitrary  script  code in the browser of an unsuspecting user in the context of the   affected site and to view arbitrary local files and directories within   the context of the webserver. This may let the attacker steal   cookie-based authentication credentials and gain access to sensitive  information,  which may aid in launching further attacks. \nVersions prior to Barco ClickShare 01.09.03, 01.06.02 and 01.03.02 are vulnerable. Barco ClickShare CSC-1 is a wireless presentation system from Barco, Belgium. Base Unit is one of the basic integration kits. The following devices are affected: Barco ClickShare CSC-1 devices with firmware prior to 01.09.03; CSM-1 devices with firmware prior to 01.06.02; CSE-200 devices with firmware prior to 01.03.02. \nA Path Traversal vulnerability exists within Barco ClickShare\u0027s wallpaper parsing functionality, which leads to disclosure of the /etc/shadow file on the file system. \n\nCVE-2016-3152 - /etc/shadow file disclosure in the CSC-1 firmware update\nAffected versions: all versions prior to v01.09.03 (CSC-1)\nIt is possible to download and extract the firmware image of the CSC-1 and obtain the root password. \n\nThe vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance. \n\nReferences:\nhttp://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020\u0026rev=001002000009\nhttp://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037\u0026rev=001001000113\nhttps://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070\u0026rev=001001000008\n\n--\n\nRegards,\n\nVincent Ruijter\nEthical Hacker\nChief Information Security Office\nKPN B.V",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2016-3150"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006880"
          },
          {
            "db": "BID",
            "id": "94330"
          },
          {
            "db": "VULHUB",
            "id": "VHN-91969"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          }
        ],
        "trust": 2.07
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2016-3150",
            "trust": 2.9
          },
          {
            "db": "PACKETSTORM",
            "id": "139713",
            "trust": 2.6
          },
          {
            "db": "BID",
            "id": "94330",
            "trust": 2.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006880",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-538",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-91969",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91969"
          },
          {
            "db": "BID",
            "id": "94330"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006880"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3150"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-538"
          }
        ]
      },
      "id": "VAR-201701-0402",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91969"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T12:29:52.408000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Update your ClickShare firmware",
            "trust": 0.8,
            "url": "https://www.barco.com/en/page/update-your-clickshare-firmware"
          },
          {
            "title": "Barco ClickShare Fixes for cross-site scripting vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=65873"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006880"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-538"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91969"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006880"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3150"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "http://packetstormsecurity.com/files/139713/barco-clickshare-xss-remote-code-execution-path-traversal.html"
          },
          {
            "trust": 1.7,
            "url": "http://www.securityfocus.com/bid/94330"
          },
          {
            "trust": 1.1,
            "url": "http://www.securityfocus.com/archive/1/539754/100/0/threaded"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-3150"
          },
          {
            "trust": 0.8,
            "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-3150"
          },
          {
            "trust": 0.6,
            "url": "http://www.securityfocus.com/archive/1/archive/1/539754/100/0/threaded"
          },
          {
            "trust": 0.3,
            "url": "https://www.barco.com/en/clickshare"
          },
          {
            "trust": 0.3,
            "url": "http://seclists.org/bugtraq/2016/nov/49"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3149"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3151"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3152"
          },
          {
            "trust": 0.1,
            "url": "http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050037\u0026rev=001001000113"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3150"
          },
          {
            "trust": 0.1,
            "url": "http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=r33050020\u0026rev=001002000009"
          },
          {
            "trust": 0.1,
            "url": "https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050070\u0026rev=001001000008"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91969"
          },
          {
            "db": "BID",
            "id": "94330"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006880"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3150"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-538"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-91969"
          },
          {
            "db": "BID",
            "id": "94330"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006880"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3150"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-538"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-01-12T00:00:00",
            "db": "VULHUB",
            "id": "VHN-91969"
          },
          {
            "date": "2016-11-14T00:00:00",
            "db": "BID",
            "id": "94330"
          },
          {
            "date": "2017-01-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2016-006880"
          },
          {
            "date": "2016-11-14T17:07:07",
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "date": "2017-01-12T23:59:00.307000",
            "db": "NVD",
            "id": "CVE-2016-3150"
          },
          {
            "date": "2016-11-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201611-538"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-10-09T00:00:00",
            "db": "VULHUB",
            "id": "VHN-91969"
          },
          {
            "date": "2016-11-24T01:10:00",
            "db": "BID",
            "id": "94330"
          },
          {
            "date": "2017-01-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2016-006880"
          },
          {
            "date": "2018-10-09T19:59:47.147000",
            "db": "NVD",
            "id": "CVE-2016-3150"
          },
          {
            "date": "2017-01-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201611-538"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-538"
          }
        ],
        "trust": 0.7
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Barco ClickShare Device product firmware  Base Unit of  wallpaper.php Vulnerable to cross-site scripting",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006880"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "XSS",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-538"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201701-0401

    Vulnerability from variot - Updated: 2023-12-18 12:29

    Barco ClickShare CSC-1 devices with firmware before 01.09.03 and CSM-1 devices with firmware before 01.06.02 allow remote attackers to execute arbitrary code via unspecified vectors. Barco ClickShare is prone to a remote code-execution vulnerability. Failed exploit attempts may cause a denial-of-service condition. Versions prior to Barco ClickShare 01.09.03 and 01.06.02 are vulnerable. Barco ClickShare CSC-1 etc. are wireless presentation systems of Belgium Barco (Barco).

    CVE-2016-3150 - Cross-site Scripting in Barco ClickShare CSC-1, CSM-1 and CSE-200 Affected versions: all versions prior to v01.09.03 (CSC-1), v01.06.02 (CSM-1) and v01.03.02 (CSE-200) A Cross-Site Scripting vulnerability exists within Barco ClickShare's CSC-1 base unit's wallpaper.php due to invalid input and output sanitisation. A Path Traversal vulnerability exists within Barco ClickShare's wallpaper parsing functionality, which leads to disclosure of the /etc/shadow file on the file system.

    CVE-2016-3152 - /etc/shadow file disclosure in the CSC-1 firmware update Affected versions: all versions prior to v01.09.03 (CSC-1) It is possible to download and extract the firmware image of the CSC-1 and obtain the root password.

    The vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance.

    References: http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020&rev=001002000009 http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037&rev=001001000113 https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070&rev=001001000008

    --

    Regards,

    Vincent Ruijter Ethical Hacker Chief Information Security Office KPN B.V

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201701-0401",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare csm-1",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "barco",
            "version": "01.06.01.04"
          },
          {
            "model": "clickshare csc-1",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "barco",
            "version": "01.09.02.03"
          },
          {
            "model": "clickshare csc-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "barco",
            "version": null
          },
          {
            "model": "clickshare csc-1",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "barco",
            "version": "01.09.03"
          },
          {
            "model": "clickshare csm-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "barco",
            "version": null
          },
          {
            "model": "clickshare csm-1",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "barco",
            "version": "01.06.02"
          },
          {
            "model": "clickshare csm-1",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "01.06.01.04"
          },
          {
            "model": "clickshare csc-1",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "01.09.02.03"
          },
          {
            "model": "clickshare",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.9.2"
          },
          {
            "model": "clickshare",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.6.1"
          },
          {
            "model": "clickshare",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.9.3"
          },
          {
            "model": "clickshare",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.6.2"
          }
        ],
        "sources": [
          {
            "db": "BID",
            "id": "94323"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006879"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3149"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-540"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_csc-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "01.09.02.03",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_csc-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_csm-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "01.06.01.04",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_csm-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2016-3149"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vincent Ruijter",
        "sources": [
          {
            "db": "BID",
            "id": "94323"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-540"
          }
        ],
        "trust": 1.0
      },
      "cve": "CVE-2016-3149",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": true,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 10.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2016-3149",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.9,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-91968",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2016-3149",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2016-3149",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201611-540",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-91968",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2016-3149",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91968"
          },
          {
            "db": "VULMON",
            "id": "CVE-2016-3149"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006879"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3149"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-540"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare CSC-1 devices with firmware before 01.09.03 and CSM-1 devices with firmware before 01.06.02 allow remote attackers to execute arbitrary code via unspecified vectors. Barco ClickShare is prone to a remote code-execution vulnerability. Failed exploit attempts may cause a denial-of-service condition. \nVersions prior to Barco ClickShare 01.09.03 and 01.06.02 are vulnerable. Barco ClickShare CSC-1 etc. are wireless presentation systems of Belgium Barco (Barco). \n\nCVE-2016-3150 - Cross-site Scripting in Barco ClickShare CSC-1, CSM-1 and CSE-200\nAffected versions:  all versions prior to v01.09.03 (CSC-1), v01.06.02 (CSM-1) and v01.03.02 (CSE-200)\nA Cross-Site Scripting vulnerability exists within Barco ClickShare\u0027s CSC-1 base unit\u0027s wallpaper.php due to invalid input and output sanitisation. \nA Path Traversal vulnerability exists within Barco ClickShare\u0027s wallpaper parsing functionality, which leads to disclosure of the /etc/shadow file on the file system. \n\nCVE-2016-3152 - /etc/shadow file disclosure in the CSC-1 firmware update\nAffected versions: all versions prior to v01.09.03 (CSC-1)\nIt is possible to download and extract the firmware image of the CSC-1 and obtain the root password. \n\nThe vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance. \n\nReferences:\nhttp://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020\u0026rev=001002000009\nhttp://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037\u0026rev=001001000113\nhttps://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070\u0026rev=001001000008\n\n--\n\nRegards,\n\nVincent Ruijter\nEthical Hacker\nChief Information Security Office\nKPN B.V",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2016-3149"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006879"
          },
          {
            "db": "BID",
            "id": "94323"
          },
          {
            "db": "VULHUB",
            "id": "VHN-91968"
          },
          {
            "db": "VULMON",
            "id": "CVE-2016-3149"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2016-3149",
            "trust": 3.0
          },
          {
            "db": "PACKETSTORM",
            "id": "139713",
            "trust": 2.7
          },
          {
            "db": "BID",
            "id": "94323",
            "trust": 2.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006879",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-540",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-91968",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2016-3149",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91968"
          },
          {
            "db": "VULMON",
            "id": "CVE-2016-3149"
          },
          {
            "db": "BID",
            "id": "94323"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006879"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3149"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-540"
          }
        ]
      },
      "id": "VAR-201701-0401",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91968"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T12:29:52.373000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Update your ClickShare firmware",
            "trust": 0.8,
            "url": "https://www.barco.com/en/page/update-your-clickshare-firmware"
          },
          {
            "title": "Barco ClickShare Fixes for remote code execution vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=65875"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006879"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-540"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2016-3149"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "http://packetstormsecurity.com/files/139713/barco-clickshare-xss-remote-code-execution-path-traversal.html"
          },
          {
            "trust": 1.9,
            "url": "http://www.securityfocus.com/bid/94323"
          },
          {
            "trust": 1.2,
            "url": "http://www.securityfocus.com/archive/1/539754/100/0/threaded"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-3149"
          },
          {
            "trust": 0.8,
            "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-3149"
          },
          {
            "trust": 0.6,
            "url": "http://www.securityfocus.com/archive/1/archive/1/539754/100/0/threaded"
          },
          {
            "trust": 0.3,
            "url": "https://www.barco.com/en/clickshare"
          },
          {
            "trust": 0.3,
            "url": "http://seclists.org/bugtraq/2016/nov/49"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3149"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3151"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3152"
          },
          {
            "trust": 0.1,
            "url": "http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050037\u0026rev=001001000113"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3150"
          },
          {
            "trust": 0.1,
            "url": "http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=r33050020\u0026rev=001002000009"
          },
          {
            "trust": 0.1,
            "url": "https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050070\u0026rev=001001000008"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91968"
          },
          {
            "db": "VULMON",
            "id": "CVE-2016-3149"
          },
          {
            "db": "BID",
            "id": "94323"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006879"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3149"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-540"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-91968"
          },
          {
            "db": "VULMON",
            "id": "CVE-2016-3149"
          },
          {
            "db": "BID",
            "id": "94323"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006879"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3149"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-540"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-01-12T00:00:00",
            "db": "VULHUB",
            "id": "VHN-91968"
          },
          {
            "date": "2017-01-12T00:00:00",
            "db": "VULMON",
            "id": "CVE-2016-3149"
          },
          {
            "date": "2016-11-14T00:00:00",
            "db": "BID",
            "id": "94323"
          },
          {
            "date": "2017-01-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2016-006879"
          },
          {
            "date": "2016-11-14T17:07:07",
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "date": "2017-01-12T23:59:00.260000",
            "db": "NVD",
            "id": "CVE-2016-3149"
          },
          {
            "date": "2016-11-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201611-540"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-10-09T00:00:00",
            "db": "VULHUB",
            "id": "VHN-91968"
          },
          {
            "date": "2018-10-09T00:00:00",
            "db": "VULMON",
            "id": "CVE-2016-3149"
          },
          {
            "date": "2016-11-24T00:10:00",
            "db": "BID",
            "id": "94323"
          },
          {
            "date": "2017-01-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2016-006879"
          },
          {
            "date": "2018-10-09T19:59:46.817000",
            "db": "NVD",
            "id": "CVE-2016-3149"
          },
          {
            "date": "2017-01-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201611-540"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-540"
          }
        ],
        "trust": 0.7
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare CSC-1 and  CSM-1 Vulnerability to execute arbitrary code in device firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006879"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "lack of information",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-540"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201701-0403

    Vulnerability from variot - Updated: 2023-12-18 12:29

    Directory traversal vulnerability in the wallpaper parsing functionality in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to read /etc/shadow via unspecified vectors. Barco ClickShare is prone to a cross-site scripting vulnerability and a directory-traversal vulnerability because it fails to sufficiently sanitize user-supplied input. A remote attacker can leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site and to view arbitrary local files and directories within the context of the webserver. This may let the attacker steal cookie-based authentication credentials and gain access to sensitive information, which may aid in launching further attacks. Versions prior to Barco ClickShare 01.09.03, 01.06.02 and 01.03.02 are vulnerable. Barco ClickShare CSC-1 etc. are wireless presentation systems of Belgium Barco (Barco). A remote attacker can exploit this vulnerability to read the /etc/shadow file.

    CVE-2016-3152 - /etc/shadow file disclosure in the CSC-1 firmware update Affected versions: all versions prior to v01.09.03 (CSC-1) It is possible to download and extract the firmware image of the CSC-1 and obtain the root password.

    The vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance.

    References: http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020&rev=001002000009 http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037&rev=001001000113 https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070&rev=001001000008

    --

    Regards,

    Vincent Ruijter Ethical Hacker Chief Information Security Office KPN B.V

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201701-0403",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare cse-200",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "barco",
            "version": "01.03.01.05"
          },
          {
            "model": "clickshare csm-1",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "barco",
            "version": "01.06.01.04"
          },
          {
            "model": "clickshare csc-1",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "barco",
            "version": "01.09.02.03"
          },
          {
            "model": "clickshare csc-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "barco",
            "version": null
          },
          {
            "model": "clickshare csc-1",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "barco",
            "version": "01.09.03"
          },
          {
            "model": "clickshare cse-200",
            "scope": null,
            "trust": 0.8,
            "vendor": "barco",
            "version": null
          },
          {
            "model": "clickshare cse-200",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "barco",
            "version": "01.03.02"
          },
          {
            "model": "clickshare csm-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "barco",
            "version": null
          },
          {
            "model": "clickshare csm-1",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "barco",
            "version": "01.06.02"
          },
          {
            "model": "clickshare csm-1",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "01.06.01.04"
          },
          {
            "model": "clickshare csc-1",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "01.09.02.03"
          },
          {
            "model": "clickshare cse-200",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "01.03.01.05"
          },
          {
            "model": "clickshare",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.9.2"
          },
          {
            "model": "clickshare",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.6.1"
          },
          {
            "model": "clickshare",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.3.1"
          },
          {
            "model": "clickshare",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.9.3"
          },
          {
            "model": "clickshare",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.6.2"
          },
          {
            "model": "clickshare",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.3.2"
          }
        ],
        "sources": [
          {
            "db": "BID",
            "id": "94330"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006881"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3151"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-539"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_csc-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "01.09.02.03",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_csc-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_csm-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "01.06.01.04",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_csm-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "01.03.01.05",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2016-3151"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vincent Ruijter",
        "sources": [
          {
            "db": "BID",
            "id": "94330"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-539"
          }
        ],
        "trust": 1.0
      },
      "cve": "CVE-2016-3151",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": true,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.0,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2016-3151",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-91970",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2016-3151",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2016-3151",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201611-539",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-91970",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91970"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006881"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3151"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-539"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Directory traversal vulnerability in the wallpaper parsing functionality in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to read /etc/shadow via unspecified vectors. Barco ClickShare is prone to a cross-site scripting vulnerability and a directory-traversal vulnerability because it fails to sufficiently sanitize user-supplied input. \nA remote attacker can leverage these issues to execute arbitrary  script  code in the browser of an unsuspecting user in the context of the   affected site and to view arbitrary local files and directories within   the context of the webserver. This may let the attacker steal   cookie-based authentication credentials and gain access to sensitive  information,  which may aid in launching further attacks. \nVersions prior to Barco ClickShare 01.09.03, 01.06.02 and 01.03.02 are vulnerable. Barco ClickShare CSC-1 etc. are wireless presentation systems of Belgium Barco (Barco). A remote attacker can exploit this vulnerability to read the /etc/shadow file. \n\nCVE-2016-3152 - /etc/shadow file disclosure in the CSC-1 firmware update\nAffected versions: all versions prior to v01.09.03 (CSC-1)\nIt is possible to download and extract the firmware image of the CSC-1 and obtain the root password. \n\nThe vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance. \n\nReferences:\nhttp://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020\u0026rev=001002000009\nhttp://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037\u0026rev=001001000113\nhttps://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070\u0026rev=001001000008\n\n--\n\nRegards,\n\nVincent Ruijter\nEthical Hacker\nChief Information Security Office\nKPN B.V",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2016-3151"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006881"
          },
          {
            "db": "BID",
            "id": "94330"
          },
          {
            "db": "VULHUB",
            "id": "VHN-91970"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          }
        ],
        "trust": 2.07
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2016-3151",
            "trust": 2.9
          },
          {
            "db": "PACKETSTORM",
            "id": "139713",
            "trust": 2.6
          },
          {
            "db": "BID",
            "id": "94330",
            "trust": 2.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006881",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-539",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-91970",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91970"
          },
          {
            "db": "BID",
            "id": "94330"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006881"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3151"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-539"
          }
        ]
      },
      "id": "VAR-201701-0403",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91970"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T12:29:52.339000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Update your ClickShare firmware",
            "trust": 0.8,
            "url": "https://www.barco.com/en/page/update-your-clickshare-firmware"
          },
          {
            "title": "Barco ClickShare Repair measures for path traversal vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=65874"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006881"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-539"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-22",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91970"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006881"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3151"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "http://packetstormsecurity.com/files/139713/barco-clickshare-xss-remote-code-execution-path-traversal.html"
          },
          {
            "trust": 1.7,
            "url": "http://www.securityfocus.com/bid/94330"
          },
          {
            "trust": 1.1,
            "url": "http://www.securityfocus.com/archive/1/539754/100/0/threaded"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-3151"
          },
          {
            "trust": 0.8,
            "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-3151"
          },
          {
            "trust": 0.6,
            "url": "http://www.securityfocus.com/archive/1/archive/1/539754/100/0/threaded"
          },
          {
            "trust": 0.3,
            "url": "https://www.barco.com/en/clickshare"
          },
          {
            "trust": 0.3,
            "url": "http://seclists.org/bugtraq/2016/nov/49"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3149"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3151"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3152"
          },
          {
            "trust": 0.1,
            "url": "http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050037\u0026rev=001001000113"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3150"
          },
          {
            "trust": 0.1,
            "url": "http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=r33050020\u0026rev=001002000009"
          },
          {
            "trust": 0.1,
            "url": "https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050070\u0026rev=001001000008"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91970"
          },
          {
            "db": "BID",
            "id": "94330"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006881"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3151"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-539"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-91970"
          },
          {
            "db": "BID",
            "id": "94330"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006881"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3151"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-539"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-01-12T00:00:00",
            "db": "VULHUB",
            "id": "VHN-91970"
          },
          {
            "date": "2016-11-14T00:00:00",
            "db": "BID",
            "id": "94330"
          },
          {
            "date": "2017-01-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2016-006881"
          },
          {
            "date": "2016-11-14T17:07:07",
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "date": "2017-01-12T23:59:00.353000",
            "db": "NVD",
            "id": "CVE-2016-3151"
          },
          {
            "date": "2016-11-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201611-539"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-10-09T00:00:00",
            "db": "VULHUB",
            "id": "VHN-91970"
          },
          {
            "date": "2016-11-24T01:10:00",
            "db": "BID",
            "id": "94330"
          },
          {
            "date": "2017-01-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2016-006881"
          },
          {
            "date": "2018-10-09T19:59:47.473000",
            "db": "NVD",
            "id": "CVE-2016-3151"
          },
          {
            "date": "2017-01-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201611-539"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-539"
          }
        ],
        "trust": 0.7
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Barco ClickShare Directory traversal vulnerability in wallpaper parsing function of device product firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006881"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "path traversal",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-539"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201701-0404

    Vulnerability from variot - Updated: 2023-12-18 12:29

    Barco ClickShare CSC-1 devices with firmware before 01.09.03 allow remote attackers to obtain the root password by downloading and extracting the firmware image. Barco ClickShare is prone to a vulnerability that lets attacker access arbitrary files because it fails to adequately validate user-supplied input. An attacker can exploit this vulnerability to view arbitrary files within the context of the affected application. Versions prior to Barco ClickShare 01.09.03 are vulnerable. Barco ClickShare CSC-1 is a wireless presentation system from Barco, Belgium. Base Unit is one of the basic integration kits. A remote code execution vulnerability exists within the Barco ClickShare base unit software, that could lead to full compromise of the appliance.

    CVE-2016-3150 - Cross-site Scripting in Barco ClickShare CSC-1, CSM-1 and CSE-200 Affected versions: all versions prior to v01.09.03 (CSC-1), v01.06.02 (CSM-1) and v01.03.02 (CSE-200) A Cross-Site Scripting vulnerability exists within Barco ClickShare's CSC-1 base unit's wallpaper.php due to invalid input and output sanitisation. A Path Traversal vulnerability exists within Barco ClickShare's wallpaper parsing functionality, which leads to disclosure of the /etc/shadow file on the file system.

    The vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance.

    References: http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020&rev=001002000009 http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037&rev=001001000113 https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070&rev=001001000008

    --

    Regards,

    Vincent Ruijter Ethical Hacker Chief Information Security Office KPN B.V

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201701-0404",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare csc-1",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "barco",
            "version": "01.09.02.03"
          },
          {
            "model": "clickshare csc-1",
            "scope": null,
            "trust": 0.8,
            "vendor": "barco",
            "version": null
          },
          {
            "model": "clickshare csc-1",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "barco",
            "version": "01.09.03"
          },
          {
            "model": "clickshare csc-1",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "01.09.02.03"
          },
          {
            "model": "clickshare",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.9.2"
          },
          {
            "model": "clickshare",
            "scope": "ne",
            "trust": 0.3,
            "vendor": "barco",
            "version": "1.9.3"
          }
        ],
        "sources": [
          {
            "db": "BID",
            "id": "94326"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006882"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3152"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-542"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_csc-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "01.09.02.03",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_csc-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2016-3152"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Vincent Ruijter",
        "sources": [
          {
            "db": "BID",
            "id": "94326"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-542"
          }
        ],
        "trust": 1.0
      },
      "cve": "CVE-2016-3152",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.0,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2016-3152",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-91971",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2016-3152",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2016-3152",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201611-542",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-91971",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91971"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006882"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3152"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-542"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare CSC-1 devices with firmware before 01.09.03 allow remote attackers to obtain the root password by downloading and extracting the firmware image. Barco ClickShare is prone to a vulnerability that lets attacker access arbitrary files because it fails to adequately validate user-supplied input. \nAn attacker can exploit this vulnerability to view arbitrary files within the context of the affected application. \nVersions prior to Barco ClickShare 01.09.03 are vulnerable. Barco ClickShare CSC-1 is a wireless presentation system from Barco, Belgium. Base Unit is one of the basic integration kits. \nA remote code execution vulnerability exists within the Barco ClickShare base unit software, that could lead to full compromise of the appliance. \n\nCVE-2016-3150 - Cross-site Scripting in Barco ClickShare CSC-1, CSM-1 and CSE-200\nAffected versions:  all versions prior to v01.09.03 (CSC-1), v01.06.02 (CSM-1) and v01.03.02 (CSE-200)\nA Cross-Site Scripting vulnerability exists within Barco ClickShare\u0027s CSC-1 base unit\u0027s wallpaper.php due to invalid input and output sanitisation. \nA Path Traversal vulnerability exists within Barco ClickShare\u0027s wallpaper parsing functionality, which leads to disclosure of the /etc/shadow file on the file system. \n\nThe vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance. \n\nReferences:\nhttp://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020\u0026rev=001002000009\nhttp://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037\u0026rev=001001000113\nhttps://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070\u0026rev=001001000008\n\n--\n\nRegards,\n\nVincent Ruijter\nEthical Hacker\nChief Information Security Office\nKPN B.V",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2016-3152"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006882"
          },
          {
            "db": "BID",
            "id": "94326"
          },
          {
            "db": "VULHUB",
            "id": "VHN-91971"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          }
        ],
        "trust": 2.07
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2016-3152",
            "trust": 2.9
          },
          {
            "db": "PACKETSTORM",
            "id": "139713",
            "trust": 2.6
          },
          {
            "db": "BID",
            "id": "94326",
            "trust": 2.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006882",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-542",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-91971",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91971"
          },
          {
            "db": "BID",
            "id": "94326"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006882"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3152"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-542"
          }
        ]
      },
      "id": "VAR-201701-0404",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91971"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T12:29:52.306000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Update your ClickShare firmware",
            "trust": 0.8,
            "url": "https://www.barco.com/en/page/update-your-clickshare-firmware"
          },
          {
            "title": "Barco ClickShare Repair measures for information disclosure vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=65877"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006882"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-542"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-200",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91971"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006882"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3152"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "http://packetstormsecurity.com/files/139713/barco-clickshare-xss-remote-code-execution-path-traversal.html"
          },
          {
            "trust": 1.7,
            "url": "http://www.securityfocus.com/bid/94326"
          },
          {
            "trust": 1.1,
            "url": "http://www.securityfocus.com/archive/1/539754/100/0/threaded"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-3152"
          },
          {
            "trust": 0.8,
            "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-3152"
          },
          {
            "trust": 0.6,
            "url": "http://www.securityfocus.com/archive/1/archive/1/539754/100/0/threaded"
          },
          {
            "trust": 0.3,
            "url": "https://www.barco.com/en/clickshare"
          },
          {
            "trust": 0.3,
            "url": "http://seclists.org/bugtraq/2016/nov/49"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3149"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3151"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3152"
          },
          {
            "trust": 0.1,
            "url": "http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050037\u0026rev=001001000113"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2016-3150"
          },
          {
            "trust": 0.1,
            "url": "http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=r33050020\u0026rev=001002000009"
          },
          {
            "trust": 0.1,
            "url": "https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050070\u0026rev=001001000008"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-91971"
          },
          {
            "db": "BID",
            "id": "94326"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006882"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3152"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-542"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-91971"
          },
          {
            "db": "BID",
            "id": "94326"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006882"
          },
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "NVD",
            "id": "CVE-2016-3152"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-542"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-01-12T00:00:00",
            "db": "VULHUB",
            "id": "VHN-91971"
          },
          {
            "date": "2016-11-14T00:00:00",
            "db": "BID",
            "id": "94326"
          },
          {
            "date": "2017-01-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2016-006882"
          },
          {
            "date": "2016-11-14T17:07:07",
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "date": "2017-01-12T23:59:00.387000",
            "db": "NVD",
            "id": "CVE-2016-3152"
          },
          {
            "date": "2016-11-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201611-542"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-10-09T00:00:00",
            "db": "VULHUB",
            "id": "VHN-91971"
          },
          {
            "date": "2016-11-24T00:10:00",
            "db": "BID",
            "id": "94326"
          },
          {
            "date": "2017-01-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2016-006882"
          },
          {
            "date": "2018-10-09T19:59:47.817000",
            "db": "NVD",
            "id": "CVE-2016-3152"
          },
          {
            "date": "2017-01-13T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201611-542"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "PACKETSTORM",
            "id": "139713"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-542"
          }
        ],
        "trust": 0.7
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare CSC-1 In the device firmware  root Password acquisition vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2016-006882"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "information disclosure",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201611-542"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201912-0678

    Vulnerability from variot - Updated: 2023-12-18 12:17

    On Barco ClickShare Button R9861500D01 devices (before firmware version 1.9.0) JTAG access is disabled after ROM code execution. This means that JTAG access is possible when the system is running code from ROM before handing control over to embedded firmware. Barco ClickShare Button R9861500D01 The device contains an input validation vulnerability.Information may be obtained

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201912-0678",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare cs-100",
            "scope": "lt",
            "trust": 1.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200",
            "scope": "lt",
            "trust": 1.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-800",
            "scope": "lt",
            "trust": 1.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200\\+",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200+",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare button r9861500d01",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.8.2.2"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.6.1.2"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.7.0.22"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.5.0.12"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.5.2.3"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": null
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.6.4.4"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.5.1.2"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.7.1.1"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.6.2.7"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46445"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013804"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18827"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-728"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cs-100_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cs-100:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200\\+_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200\\+:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-800_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-800:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18827"
          }
        ]
      },
      "cve": "CVE-2019-18827",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.3,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2019-18827",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.4,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-46445",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.2,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "High",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.9,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-18827",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-18827",
                "trust": 1.8,
                "value": "MEDIUM"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-46445",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201912-728",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46445"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013804"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18827"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-728"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "On Barco ClickShare Button R9861500D01 devices (before firmware version 1.9.0) JTAG access is disabled after ROM code execution. This means that JTAG access is possible when the system is running code from ROM before handing control over to embedded firmware. Barco ClickShare Button R9861500D01 The device contains an input validation vulnerability.Information may be obtained",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18827"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013804"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-46445"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-18827",
            "trust": 3.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013804",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-46445",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-728",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46445"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013804"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18827"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-728"
          }
        ]
      },
      "id": "VAR-201912-0678",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46445"
          }
        ],
        "trust": 1.3368421000000001
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46445"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:17:30.724000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Update your ClickShare device",
            "trust": 0.8,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "title": "ClickShare CS-100 base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "ClickShare CSE-200 base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "ClickShare CSE-800 base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "ClickShare CSE-200+ base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "Patch for Barco ClickShare Button R9861500D01 has an unknown vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/194993"
          },
          {
            "title": "Barco ClickShare Button R9861500D01 Enter the fix for the verification error vulnerability",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105993"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46445"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013804"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-728"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-285",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-362",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-20",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013804"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18827"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.2,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "trust": 2.2,
            "url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-18827"
          },
          {
            "trust": 1.6,
            "url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18827"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46445"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013804"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18827"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-728"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46445"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013804"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18827"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-728"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-12-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-46445"
          },
          {
            "date": "2020-01-16T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013804"
          },
          {
            "date": "2019-12-16T17:15:11.957000",
            "db": "NVD",
            "id": "CVE-2019-18827"
          },
          {
            "date": "2019-12-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-728"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-12-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-46445"
          },
          {
            "date": "2020-01-16T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013804"
          },
          {
            "date": "2021-07-21T11:39:23.747000",
            "db": "NVD",
            "id": "CVE-2019-18827"
          },
          {
            "date": "2019-12-30T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-728"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-728"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 Vulnerability related to input validation on devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013804"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "input validation error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-728"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202011-0849

    Vulnerability from variot - Updated: 2023-12-18 12:16

    Barco wePresent WiPG-1600W devices use Hard-coded Credentials (issue 2 of 2). Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W device has a hardcoded root password hash included in the firmware image. Exploiting CVE-2020-28329, CVE-2020-28330 and CVE-2020-28331 could potentially be used in a simple and automated exploit chain to go from unauthenticated remote attacker to root shell. Barco wePresent WiPG-1600W A device contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Barco wePresent WiPG-1600W is a management device used in conference environments from Barco in Belgium

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202011-0849",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wepresent wipg-1600w",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "barco",
            "version": "2.5.1.8"
          },
          {
            "model": "wepresent wipg-1600w",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "barco",
            "version": "2.5.0.25"
          },
          {
            "model": "wepresent wipg-1600w",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "barco",
            "version": "2.5.0.24"
          },
          {
            "model": "wepresent wipg-1600w",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "barco",
            "version": "2.4.1.19"
          },
          {
            "model": "wepresent wipg-1600w",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "wepresent wipg-1600w  firmware  2.5.0.25"
          },
          {
            "model": "wepresent wipg-1600w",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "wepresent wipg-1600w  firmware  2.4.1.19"
          },
          {
            "model": "wepresent wipg-1600w",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "wepresent wipg-1600w  firmware  2.5.0.24"
          },
          {
            "model": "wepresent wipg-1600w",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": null
          },
          {
            "model": "wepresent wipg-1600w",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "wepresent wipg-1600w  firmware  2.5.1.8"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-67561"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-013882"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-28334"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:2.4.1.19:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:2.5.0.24:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:2.5.0.25:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:2.5.1.8:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:wepresent_wipg-1600w:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-28334"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Jim Becher",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202011-1775"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2020-28334",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 10.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2020-28334",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2020-67561",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-28334",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2020-28334",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2020-67561",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202011-1775",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-67561"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-013882"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-28334"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202011-1775"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco wePresent WiPG-1600W devices use Hard-coded Credentials (issue 2 of 2). Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W device has a hardcoded root password hash included in the firmware image. Exploiting CVE-2020-28329, CVE-2020-28330 and CVE-2020-28331 could potentially be used in a simple and automated exploit chain to go from unauthenticated remote attacker to root shell. Barco wePresent WiPG-1600W A device contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Barco wePresent WiPG-1600W is a management device used in conference environments from Barco in Belgium",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-28334"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-013882"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-67561"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "PACKETSTORM",
            "id": "160163",
            "trust": 3.0
          },
          {
            "db": "NVD",
            "id": "CVE-2020-28334",
            "trust": 3.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-013882",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-67561",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202011-1775",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-67561"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-013882"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-28334"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202011-1775"
          }
        ]
      },
      "id": "VAR-202011-0849",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-67561"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-67561"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:16:47.061000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "wePresent\u00a0WiPG-1600W",
            "trust": 0.8,
            "url": "https://www.barco.com/en/product/wepresent-wipg-1600w"
          },
          {
            "title": "Patch for Barco wePresent WiPG-1600W hardcoded root password vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/241405"
          },
          {
            "title": "Barco wePresent WiPG-1600W Repair measures for trust management problem vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=135798"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-67561"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-013882"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202011-1775"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-798",
            "trust": 1.0
          },
          {
            "problemtype": "Using hardcoded credentials (CWE-798) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-013882"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-28334"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.6,
            "url": "http://packetstormsecurity.com/files/160163/barco-wepresent-global-hardcoded-root-ssh-password.html"
          },
          {
            "trust": 1.6,
            "url": "https://korelogic.com/resources/advisories/kl-001-2020-008.txt"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28334"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-67561"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-013882"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-28334"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202011-1775"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-67561"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-013882"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-28334"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202011-1775"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-11-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-67561"
          },
          {
            "date": "2021-07-14T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-013882"
          },
          {
            "date": "2020-11-24T19:15:10.867000",
            "db": "NVD",
            "id": "CVE-2020-28334"
          },
          {
            "date": "2020-11-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202011-1775"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-11-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-67561"
          },
          {
            "date": "2021-07-14T08:23:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-013882"
          },
          {
            "date": "2020-12-03T17:39:44.927000",
            "db": "NVD",
            "id": "CVE-2020-28334"
          },
          {
            "date": "2020-12-04T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202011-1775"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202011-1775"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco\u00a0wePresent\u00a0WiPG-1600W\u00a0 Vulnerability in using hard-coded credentials on devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-013882"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "trust management problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202011-1775"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201710-0927

    Vulnerability from variot - Updated: 2023-12-18 12:03

    An issue was discovered in Barco ClickShare CSM-1 firmware before v1.7.0.3 and CSC-1 firmware before v1.10.0.10. An authenticated user can manage the wallpaper collection in the webUI to be shown as background on the ClickShare product. By uploading a wallpaper with a specially crafted name, an HTML injection can be triggered as special characters are not neutralized before output. Barco ClickShare CSM-1 and CSC-1 The firmware contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. BarcoClickShareCSM-1 and ClickShareCSC-1 are both host devices for Barco's wireless presentation system. BarcoClickShareCSM-1 with firmware prior to 1.7.0.3 and BarcoClickShareCSC-1 with firmware prior to 1.10.0.10 have security vulnerabilities. There are currently no detailed details of the vulnerability provided

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201710-0927",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare csc-1",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "barco",
            "version": "1.10.0.10"
          },
          {
            "model": "clickshare csm-1",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "barco",
            "version": "1.7.0.3"
          },
          {
            "model": "clickshare csc-1",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "barco",
            "version": "v1.10.0.10"
          },
          {
            "model": "clickshare csm-1",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "barco",
            "version": "v1.7.0.3"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-36376"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009767"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-12460"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_csm-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.7.0.3",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_csm-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_csc-1_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.10.0.10",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_csc-1:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-12460"
          }
        ]
      },
      "cve": "CVE-2017-12460",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "LOW",
                "trust": 1.0,
                "userInteractionRequired": true,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 3.5,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2017-12460",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Low",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CNVD-2017-36376",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.3,
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.4,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2017-12460",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "Low",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2017-12460",
                "trust": 1.8,
                "value": "MEDIUM"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-36376",
                "trust": 0.6,
                "value": "LOW"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201710-1240",
                "trust": 0.6,
                "value": "LOW"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-36376"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009767"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-12460"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201710-1240"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An issue was discovered in Barco ClickShare CSM-1 firmware before v1.7.0.3 and CSC-1 firmware before v1.10.0.10.  An authenticated user can manage the wallpaper collection in the webUI to be shown as background on the ClickShare product.  By uploading a wallpaper with a specially crafted name, an HTML injection can be triggered as special characters are not neutralized before output. Barco ClickShare CSM-1 and CSC-1 The firmware contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. BarcoClickShareCSM-1 and ClickShareCSC-1 are both host devices for Barco\u0027s wireless presentation system. BarcoClickShareCSM-1 with firmware prior to 1.7.0.3 and BarcoClickShareCSC-1 with firmware prior to 1.10.0.10 have security vulnerabilities. There are currently no detailed details of the vulnerability provided",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-12460"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009767"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-36376"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-12460",
            "trust": 3.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009767",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-36376",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201710-1240",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-36376"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009767"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-12460"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201710-1240"
          }
        ]
      },
      "id": "VAR-201710-0927",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-36376"
          }
        ],
        "trust": 0.06
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-36376"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:03:12.023000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Is ClickShare protected against HTML injection? [KB5169]",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/knowledge-base/kb5169"
          },
          {
            "title": "ClickShare CSC-1 Base Unit Firmware v1.10.0.10",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050020"
          },
          {
            "title": "ClickShare CSM-1 Base Unit Firmware v1.7.0.3",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050037"
          },
          {
            "title": "BarcoClickShareCSM-1 and ClickShareCSC-1 have unexplained patches",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/107881"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-36376"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009767"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009767"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-12460"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/support/software/r33050037"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/support/software/r33050020"
          },
          {
            "trust": 1.0,
            "url": "https://www.barco.com/en/support/knowledge-base/kb5169"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-12460"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-12460"
          },
          {
            "trust": 0.6,
            "url": "http://www.barco.com.cn/en/support/software/r33050020"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-36376"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009767"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-12460"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201710-1240"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-36376"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009767"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-12460"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201710-1240"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-12-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-36376"
          },
          {
            "date": "2017-11-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-009767"
          },
          {
            "date": "2017-10-30T14:29:00.797000",
            "db": "NVD",
            "id": "CVE-2017-12460"
          },
          {
            "date": "2017-10-30T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201710-1240"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-12-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-36376"
          },
          {
            "date": "2017-11-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-009767"
          },
          {
            "date": "2017-11-18T16:21:33.540000",
            "db": "NVD",
            "id": "CVE-2017-12460"
          },
          {
            "date": "2017-11-09T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201710-1240"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201710-1240"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare CSM-1 and  CSC-1 Firmware cross-site scripting vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-009767"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "XSS",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201710-1240"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201904-0320

    Vulnerability from variot - Updated: 2023-12-18 12:00

    The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root. Crestron AM-100 There is a command injection vulnerability in products such as firmware.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. A command injection vulnerability exists in several routers. This vulnerability stems from the fact that the network system or product does not correctly filter special elements in the process of constructing executable commands from external input data

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201904-0320",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wepresent wipg-1000p",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "barco",
            "version": "2.3.0.10"
          },
          {
            "model": "wepresent wipg-1600w",
            "scope": "lt",
            "trust": 1.8,
            "vendor": "barco",
            "version": "2.4.1.19"
          },
          {
            "model": "sharelink 200",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "extron",
            "version": "2.0.3.4"
          },
          {
            "model": "sharelink 250",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "extron",
            "version": "2.0.3.4"
          },
          {
            "model": "liteshow3",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "infocus",
            "version": "1.0.16"
          },
          {
            "model": "liteshow4",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "infocus",
            "version": "2.0.0.7"
          },
          {
            "model": "wps-pro",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "optoma",
            "version": "1.0.0.5"
          },
          {
            "model": "pn-l703wa",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "sharp",
            "version": "1.4.2.3"
          },
          {
            "model": "am-100",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "crestron",
            "version": "1.6.0.2"
          },
          {
            "model": "am-101",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "crestron",
            "version": "2.7.0.2"
          },
          {
            "model": "hd wireless presentation system",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "blackbox",
            "version": "1.0.0.5"
          },
          {
            "model": "wips710",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "teqavit",
            "version": "1.1.0.7"
          },
          {
            "model": "hd wireless presentation system",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "black box network services",
            "version": "1.0.0.5"
          },
          {
            "model": "airmedia am-100",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "crestron",
            "version": "1.6.0.2"
          },
          {
            "model": "airmedia am-101",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "crestron",
            "version": "2.7.0.1"
          },
          {
            "model": "wips710",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "teq avit",
            "version": "1.1.0.7"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004073"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3929"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:crestron:am-100_firmware:1.6.0.2:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:crestron:am-100:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:crestron:am-101_firmware:2.7.0.2:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:crestron:am-101:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1000p_firmware:2.3.0.10:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:wepresent_wipg-1000p:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.4.1.19",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:wepresent_wipg-1600w:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:extron:sharelink_200_firmware:2.0.3.4:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:extron:sharelink_200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:extron:sharelink_250_firmware:2.0.3.4:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:extron:sharelink_250:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:teqavit:wips710_firmware:1.1.0.7:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:teqavit:wips710:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:sharp:pn-l703wa_firmware:1.4.2.3:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:sharp:pn-l703wa:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:optoma:wps-pro_firmware:1.0.0.5:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:optoma:wps-pro:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:blackbox:hd_wireless_presentation_system_firmware:1.0.0.5:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:blackbox:hd_wireless_presentation_system:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:infocus:liteshow3_firmware:1.0.16:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:infocus:liteshow3:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:infocus:liteshow4_firmware:2.0.0.7:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:infocus:liteshow4:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-3929"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Jacob Baines",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1386"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2019-3929",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 10.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2019-3929",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.9,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-155364",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-3929",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-3929",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201904-1386",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-155364",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2019-3929",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155364"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-3929"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004073"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3929"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1386"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root. Crestron AM-100 There is a command injection vulnerability in products such as firmware.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. A command injection vulnerability exists in several routers. This vulnerability stems from the fact that the network system or product does not correctly filter special elements in the process of constructing executable commands from external input data",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-3929"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004073"
          },
          {
            "db": "VULHUB",
            "id": "VHN-155364"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-3929"
          }
        ],
        "trust": 1.8
      },
      "exploit_availability": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "reference": "https://www.scap.org.cn/vuln/vhn-155364",
            "trust": 0.1,
            "type": "unknown"
          },
          {
            "reference": "https://vulmon.com/exploitdetails?qidtp=exploitdb\u0026qid=46786",
            "trust": 0.1,
            "type": "exploit"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155364"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-3929"
          }
        ]
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-3929",
            "trust": 2.6
          },
          {
            "db": "TENABLE",
            "id": "TRA-2019-20",
            "trust": 2.6
          },
          {
            "db": "EXPLOIT-DB",
            "id": "46786",
            "trust": 1.8
          },
          {
            "db": "PACKETSTORM",
            "id": "155948",
            "trust": 1.8
          },
          {
            "db": "PACKETSTORM",
            "id": "152715",
            "trust": 1.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004073",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1386",
            "trust": 0.7
          },
          {
            "db": "EXPLOIT-DB",
            "id": "47924",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-155364",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-3929",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155364"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-3929"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004073"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3929"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1386"
          }
        ]
      },
      "id": "VAR-201904-0320",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155364"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T12:00:23.448000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "wePresent WiPG-1000",
            "trust": 0.8,
            "url": "https://www.barco.com/en/product/wepresent-wipg-1000"
          },
          {
            "title": "wePresent WiPG-1600W",
            "trust": 0.8,
            "url": "https://www.barco.com/en/product/wepresent-wipg-1600w"
          },
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.blackbox.com/en-us"
          },
          {
            "title": "AM-100",
            "trust": 0.8,
            "url": "https://www.crestron.com/en-us/products/workspace-solutions/wireless-presentation-solutions/airmedia-presentation-gateways/am-100"
          },
          {
            "title": "AM-101",
            "trust": 0.8,
            "url": "https://www.crestron.com/en-us/products/workspace-solutions/wireless-presentation-solutions/airmedia-presentation-gateways/am-101"
          },
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.extron.com/"
          },
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.infocus.com/"
          },
          {
            "title": "WPS Pro",
            "trust": 0.8,
            "url": "https://www.optoma.com/us/product/wps-pro/"
          },
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.teq-avit.com/"
          },
          {
            "title": "PN-L703WA",
            "trust": 0.8,
            "url": "https://jp.sharp/business/bigpad/lineup/pnl703wa/"
          },
          {
            "title": "CVE-2019-3929",
            "trust": 0.1,
            "url": "https://github.com/xfox64x/cve-2019-3929 "
          },
          {
            "title": "PoC-in-GitHub",
            "trust": 0.1,
            "url": "https://github.com/developer3000s/poc-in-github "
          },
          {
            "title": "CVE-POC",
            "trust": 0.1,
            "url": "https://github.com/0xt11/cve-poc "
          },
          {
            "title": "PoC-in-GitHub",
            "trust": 0.1,
            "url": "https://github.com/hectorgie/poc-in-github "
          },
          {
            "title": "PoC-in-GitHub",
            "trust": 0.1,
            "url": "https://github.com/nomi-sec/poc-in-github "
          },
          {
            "title": "Threatpost",
            "trust": 0.1,
            "url": "https://threatpost.com/bugs-wireless-presentation-systems/144318/"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2019-3929"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004073"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-77",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155364"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004073"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3929"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.0,
            "url": "http://packetstormsecurity.com/files/152715/barco-awind-oem-presentation-platform-unauthenticated-remote-command-injection.html"
          },
          {
            "trust": 2.6,
            "url": "https://www.tenable.com/security/research/tra-2019-20"
          },
          {
            "trust": 1.8,
            "url": "https://www.exploit-db.com/exploits/46786/"
          },
          {
            "trust": 1.8,
            "url": "http://packetstormsecurity.com/files/155948/barco-wepresent-file_transfer.cgi-command-injection.html"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-3929"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-3929"
          },
          {
            "trust": 0.7,
            "url": "https://www.exploit-db.com/exploits/46786"
          },
          {
            "trust": 0.6,
            "url": "https://www.exploit-db.com/exploits/47924"
          },
          {
            "trust": 0.6,
            "url": "https://packetstormsecurity.com/files/155948/barco-wepresent-file/transfer.cgi-command-injection.html"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/78.html"
          },
          {
            "trust": 0.1,
            "url": "https://github.com/xfox64x/cve-2019-3929"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155364"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-3929"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004073"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3929"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1386"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-155364"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-3929"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004073"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3929"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1386"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-04-30T00:00:00",
            "db": "VULHUB",
            "id": "VHN-155364"
          },
          {
            "date": "2019-04-30T00:00:00",
            "db": "VULMON",
            "id": "CVE-2019-3929"
          },
          {
            "date": "2019-05-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-004073"
          },
          {
            "date": "2019-04-30T21:29:00.713000",
            "db": "NVD",
            "id": "CVE-2019-3929"
          },
          {
            "date": "2019-04-30T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201904-1386"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-10-16T00:00:00",
            "db": "VULHUB",
            "id": "VHN-155364"
          },
          {
            "date": "2020-10-16T00:00:00",
            "db": "VULMON",
            "id": "CVE-2019-3929"
          },
          {
            "date": "2019-05-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-004073"
          },
          {
            "date": "2020-10-16T18:09:51.387000",
            "db": "NVD",
            "id": "CVE-2019-3929"
          },
          {
            "date": "2020-10-28T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201904-1386"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1386"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Crestron AM-100 Command injection vulnerability in products such as firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004073"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1386"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201904-0321

    Vulnerability from variot - Updated: 2023-12-18 12:00

    The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so's PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint. Crestron AM-100 Firmware and other products have a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. A buffer error vulnerability exists in the 'PARSERtoCHAR' function of the libAwgCgi.so file in several routers. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201904-0321",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wepresent wipg-1000p",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "barco",
            "version": "2.3.0.10"
          },
          {
            "model": "wepresent wipg-1600w",
            "scope": "lt",
            "trust": 1.8,
            "vendor": "barco",
            "version": "2.4.1.19"
          },
          {
            "model": "sharelink 200",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "extron",
            "version": "2.0.3.4"
          },
          {
            "model": "sharelink 250",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "extron",
            "version": "2.0.3.4"
          },
          {
            "model": "liteshow3",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "infocus",
            "version": "1.0.16"
          },
          {
            "model": "liteshow4",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "infocus",
            "version": "2.0.0.7"
          },
          {
            "model": "wps-pro",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "optoma",
            "version": "1.0.0.5"
          },
          {
            "model": "pn-l703wa",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "sharp",
            "version": "1.4.2.3"
          },
          {
            "model": "am-100",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "crestron",
            "version": "1.6.0.2"
          },
          {
            "model": "am-101",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "crestron",
            "version": "2.7.0.2"
          },
          {
            "model": "hd wireless presentation system",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "blackbox",
            "version": "1.0.0.5"
          },
          {
            "model": "wips710",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "teqavit",
            "version": "1.1.0.7"
          },
          {
            "model": "hd wireless presentation system",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "black box network services",
            "version": "1.0.0.5"
          },
          {
            "model": "airmedia am-100",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "crestron",
            "version": "1.6.0.2"
          },
          {
            "model": "airmedia am-101",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "crestron",
            "version": "2.7.0.1"
          },
          {
            "model": "wips710",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "teq avit",
            "version": "1.1.0.7"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004039"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3930"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:crestron:am-100_firmware:1.6.0.2:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:crestron:am-100:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:crestron:am-101_firmware:2.7.0.2:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:crestron:am-101:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1000p_firmware:2.3.0.10:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:wepresent_wipg-1000p:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "2.4.1.19",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:wepresent_wipg-1600w:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:extron:sharelink_200_firmware:2.0.3.4:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:extron:sharelink_200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:extron:sharelink_250_firmware:2.0.3.4:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:extron:sharelink_250:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:teqavit:wips710_firmware:1.1.0.7:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:teqavit:wips710:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:sharp:pn-l703wa_firmware:1.4.2.3:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:sharp:pn-l703wa:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:optoma:wps-pro_firmware:1.0.0.5:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:optoma:wps-pro:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:blackbox:hd_wireless_presentation_system_firmware:1.0.0.5:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:blackbox:hd_wireless_presentation_system:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:infocus:liteshow3_firmware:1.0.16:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:infocus:liteshow3:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:infocus:liteshow4_firmware:2.0.0.7:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:infocus:liteshow4:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-3930"
          }
        ]
      },
      "cve": "CVE-2019-3930",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 10.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2019-3930",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.9,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-155365",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-3930",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-3930",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201904-1388",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-155365",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2019-3930",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155365"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-3930"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004039"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3930"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1388"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so\u0027s PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint. Crestron AM-100 Firmware and other products have a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. A buffer error vulnerability exists in the \u0027PARSERtoCHAR\u0027 function of the libAwgCgi.so file in several routers. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-3930"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004039"
          },
          {
            "db": "VULHUB",
            "id": "VHN-155365"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-3930"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-3930",
            "trust": 2.6
          },
          {
            "db": "TENABLE",
            "id": "TRA-2019-20",
            "trust": 2.6
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004039",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1388",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-155365",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-3930",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155365"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-3930"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004039"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3930"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1388"
          }
        ]
      },
      "id": "VAR-201904-0321",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155365"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T12:00:23.341000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "wePresent WiPG-1000",
            "trust": 0.8,
            "url": "https://www.barco.com/en/product/wepresent-wipg-1000"
          },
          {
            "title": "wePresent WiPG-1600W",
            "trust": 0.8,
            "url": "https://www.barco.com/en/product/wepresent-wipg-1600w"
          },
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.blackbox.com/en-us"
          },
          {
            "title": "AM-100",
            "trust": 0.8,
            "url": "https://www.crestron.com/en-us/products/workspace-solutions/wireless-presentation-solutions/airmedia-presentation-gateways/am-100"
          },
          {
            "title": "AM-101",
            "trust": 0.8,
            "url": "https://www.crestron.com/en-us/products/workspace-solutions/wireless-presentation-solutions/airmedia-presentation-gateways/am-101"
          },
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.extron.com/"
          },
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.infocus.com/"
          },
          {
            "title": "WPS Pro",
            "trust": 0.8,
            "url": "https://www.optoma.com/us/product/wps-pro/"
          },
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.teq-avit.com/"
          },
          {
            "title": "PN-L703WA",
            "trust": 0.8,
            "url": "https://jp.sharp/business/bigpad/lineup/pnl703wa/"
          },
          {
            "title": "Threatpost",
            "trust": 0.1,
            "url": "https://threatpost.com/bugs-wireless-presentation-systems/144318/"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2019-3930"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004039"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-119",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155365"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004039"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3930"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "https://www.tenable.com/security/research/tra-2019-20"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-3930"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-3930"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/787.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://threatpost.com/bugs-wireless-presentation-systems/144318/"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-155365"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-3930"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004039"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3930"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1388"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-155365"
          },
          {
            "db": "VULMON",
            "id": "CVE-2019-3930"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004039"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-3930"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1388"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-04-30T00:00:00",
            "db": "VULHUB",
            "id": "VHN-155365"
          },
          {
            "date": "2019-04-30T00:00:00",
            "db": "VULMON",
            "id": "CVE-2019-3930"
          },
          {
            "date": "2019-05-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-004039"
          },
          {
            "date": "2019-04-30T21:29:00.777000",
            "db": "NVD",
            "id": "CVE-2019-3930"
          },
          {
            "date": "2019-04-30T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201904-1388"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-10-16T00:00:00",
            "db": "VULHUB",
            "id": "VHN-155365"
          },
          {
            "date": "2020-10-16T00:00:00",
            "db": "VULMON",
            "id": "CVE-2019-3930"
          },
          {
            "date": "2019-05-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-004039"
          },
          {
            "date": "2020-10-16T18:30:20.047000",
            "db": "NVD",
            "id": "CVE-2019-3930"
          },
          {
            "date": "2020-10-19T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201904-1388"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1388"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Crestron AM-100 Buffer error vulnerability in products such as firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-004039"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201904-1388"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201912-0679

    Vulnerability from variot - Updated: 2023-12-18 11:02

    Barco ClickShare Button R9861500D01 devices before 1.9.0 have Insufficiently Protected Credentials. The root account (present for access via debug interfaces, which are by default not enabled on production devices) of the embedded Linux on the ClickShare Button is using a weak password. Barco ClickShare Button The device contains a vulnerability related to information disclosure from the cache.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The vulnerability originated from the program's insufficient protection of credentials, and an attacker could use this vulnerability to gain root user identity

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201912-0679",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "clickshare cse-200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200\\+",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-800",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cs-100",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cs-100",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-200+",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare cse-800",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "barco",
            "version": "1.9.0"
          },
          {
            "model": "clickshare button r9861500d01",
            "scope": "lt",
            "trust": 0.6,
            "vendor": "barco",
            "version": "1.9.0"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013418"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18828"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cs-100_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cs-100:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200\\+_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200\\+:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-800_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndExcluding": "1.9.0",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-800:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18828"
          }
        ]
      },
      "cve": "CVE-2019-18828",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Local",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 7.2,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2019-18828",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-46444",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Physical",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-18828",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-18828",
                "trust": 1.8,
                "value": "MEDIUM"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-46444",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201912-727",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013418"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18828"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-727"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button R9861500D01 devices before 1.9.0 have Insufficiently Protected Credentials. The root account (present for access via debug interfaces, which are by default not enabled on production devices) of the embedded Linux on the ClickShare Button is using a weak password. Barco ClickShare Button The device contains a vulnerability related to information disclosure from the cache.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The vulnerability originated from the program\u0027s insufficient protection of credentials, and an attacker could use this vulnerability to gain root user identity",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-18828"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013418"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-46444"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-18828",
            "trust": 3.0
          },
          {
            "db": "JVN",
            "id": "JVNVU93632155",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013418",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-46444",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-727",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013418"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18828"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-727"
          }
        ]
      },
      "id": "VAR-201912-0679",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46444"
          }
        ],
        "trust": 1.3368421000000001
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46444"
          }
        ]
      },
      "last_update_date": "2023-12-18T11:02:43.021000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "ClickShare",
            "trust": 0.8,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "title": "ClickShare CS-100 base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "ClickShare CSE-200 base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "ClickShare CSE-800 base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "ClickShare CSE-200+ base unit firmware v1.9.1.7",
            "trust": 0.8,
            "url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "title": "Patch for Barco ClickShare Button R9861500D01 Insufficient Credential Protection Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/194987"
          },
          {
            "title": "Barco ClickShare Button R9861500D01 Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105750"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013418"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-727"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-521",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-522",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013418"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18828"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.2,
            "url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
          },
          {
            "trust": 2.2,
            "url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-18828"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/clickshare/firmware-update"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 1.6,
            "url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18828"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu93632155/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013418"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18828"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-727"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-46444"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013418"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-18828"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-727"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-12-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-46444"
          },
          {
            "date": "2019-12-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013418"
          },
          {
            "date": "2019-12-16T17:15:12.017000",
            "db": "NVD",
            "id": "CVE-2019-18828"
          },
          {
            "date": "2019-12-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-727"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-12-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-46444"
          },
          {
            "date": "2019-12-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-013418"
          },
          {
            "date": "2020-08-24T17:37:01.140000",
            "db": "NVD",
            "id": "CVE-2019-18828"
          },
          {
            "date": "2020-08-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201912-727"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Barco ClickShare Button Vulnerability related to information leak from cache in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-013418"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201912-727"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2022-26978 (GCVE-0-2022-26978)

    Vulnerability from nvd – Published: 2022-06-01 11:35 – Updated: 2024-08-03 05:18
    VLAI
    Summary
    Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /checklogin.jsp endpoint. The os_username parameters is not correctly sanitized, leading to reflected XSS.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:18:39.136Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/transform-n-management-server"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/knowledge-base/KB12686"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /checklogin.jsp endpoint. The os_username parameters is not correctly sanitized, leading to reflected XSS."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T11:35:22.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/transform-n-management-server"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/knowledge-base/KB12686"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-26978",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /checklogin.jsp endpoint. The os_username parameters is not correctly sanitized, leading to reflected XSS."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.barco.com/en/support/transform-n-management-server",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/transform-n-management-server"
                },
                {
                  "name": "https://www.barco.com/en/support/knowledge-base/KB12686",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/knowledge-base/KB12686"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-26978",
        "datePublished": "2022-06-01T11:35:22.000Z",
        "dateReserved": "2022-03-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:18:39.136Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26977 (GCVE-0-2022-26977)

    Vulnerability from nvd – Published: 2022-06-01 11:35 – Updated: 2024-08-03 05:18
    VLAI
    Summary
    Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization of the upload mechanism is leads to stored XSS.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:18:39.263Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/transform-n-management-server"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/knowledge-base/KB12683"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization of the upload mechanism is leads to stored XSS."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T11:35:16.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/transform-n-management-server"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/knowledge-base/KB12683"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-26977",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization of the upload mechanism is leads to stored XSS."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.barco.com/en/support/transform-n-management-server",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/transform-n-management-server"
                },
                {
                  "name": "https://www.barco.com/en/support/knowledge-base/KB12683",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/knowledge-base/KB12683"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-26977",
        "datePublished": "2022-06-01T11:35:16.000Z",
        "dateReserved": "2022-03-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:18:39.263Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26976 (GCVE-0-2022-26976)

    Vulnerability from nvd – Published: 2022-06-01 11:35 – Updated: 2024-08-03 05:18
    VLAI
    Summary
    Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization in the upload mechanism is leads to reflected XSS.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:18:39.221Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/transform-n-management-server"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/knowledge-base/KB12682"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization in the upload mechanism is leads to reflected XSS."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T11:35:06.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/transform-n-management-server"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/knowledge-base/KB12682"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-26976",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization in the upload mechanism is leads to reflected XSS."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.barco.com/en/support/transform-n-management-server",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/transform-n-management-server"
                },
                {
                  "name": "https://www.barco.com/en/support/knowledge-base/KB12682",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/knowledge-base/KB12682"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-26976",
        "datePublished": "2022-06-01T11:35:06.000Z",
        "dateReserved": "2022-03-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:18:39.221Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26975 (GCVE-0-2022-26975)

    Vulnerability from nvd – Published: 2022-06-01 11:34 – Updated: 2024-08-03 05:18
    VLAI
    Summary
    Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing log files without authentication.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:18:39.305Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/transform-n-management-server"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/knowledge-base/KB12677"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing log files without authentication."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T11:34:59.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/transform-n-management-server"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/knowledge-base/KB12677"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-26975",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing log files without authentication."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.barco.com/en/support/transform-n-management-server",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/transform-n-management-server"
                },
                {
                  "name": "https://www.barco.com/en/support/knowledge-base/KB12677",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/knowledge-base/KB12677"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-26975",
        "datePublished": "2022-06-01T11:34:59.000Z",
        "dateReserved": "2022-03-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:18:39.305Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26974 (GCVE-0-2022-26974)

    Vulnerability from nvd – Published: 2022-06-01 11:34 – Updated: 2024-08-03 05:18
    VLAI
    Summary
    Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a file upload mechanism. Lack of input sanitization in the upload mechanism leads to reflected XSS.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:18:39.396Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/transform-n-management-server"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/knowledge-base/KB12684"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a file upload mechanism. Lack of input sanitization in the upload mechanism leads to reflected XSS."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T11:34:54.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/transform-n-management-server"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/knowledge-base/KB12684"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-26974",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a file upload mechanism. Lack of input sanitization in the upload mechanism leads to reflected XSS."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.barco.com/en/support/transform-n-management-server",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/transform-n-management-server"
                },
                {
                  "name": "https://www.barco.com/en/support/knowledge-base/KB12684",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/knowledge-base/KB12684"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-26974",
        "datePublished": "2022-06-01T11:34:54.000Z",
        "dateReserved": "2022-03-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:18:39.396Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26973 (GCVE-0-2022-26973)

    Vulnerability from nvd – Published: 2022-06-01 11:34 – Updated: 2024-08-03 05:18
    VLAI
    Summary
    Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. By tweaking the license file name, the returned error message exposes internal directory path details.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:18:39.210Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/transform-n-management-server"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/knowledge-base/KB12678"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. By tweaking the license file name, the returned error message exposes internal directory path details."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T11:34:48.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/transform-n-management-server"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/knowledge-base/KB12678"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-26973",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. By tweaking the license file name, the returned error message exposes internal directory path details."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.barco.com/en/support/transform-n-management-server",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/transform-n-management-server"
                },
                {
                  "name": "https://www.barco.com/en/support/knowledge-base/KB12678",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/knowledge-base/KB12678"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-26973",
        "datePublished": "2022-06-01T11:34:48.000Z",
        "dateReserved": "2022-03-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:18:39.210Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26972 (GCVE-0-2022-26972)

    Vulnerability from nvd – Published: 2022-06-01 11:34 – Updated: 2024-08-03 05:18
    VLAI
    Summary
    Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /cgi-bin endpoint. The URL parameters are not correctly sanitized, leading to reflected XSS.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:18:38.461Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/transform-n-management-server"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/knowledge-base/KB12685"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /cgi-bin endpoint. The URL parameters are not correctly sanitized, leading to reflected XSS."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T11:34:42.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/transform-n-management-server"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/knowledge-base/KB12685"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-26972",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /cgi-bin endpoint. The URL parameters are not correctly sanitized, leading to reflected XSS."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.barco.com/en/support/transform-n-management-server",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/transform-n-management-server"
                },
                {
                  "name": "https://www.barco.com/en/support/knowledge-base/KB12685",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/knowledge-base/KB12685"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-26972",
        "datePublished": "2022-06-01T11:34:42.000Z",
        "dateReserved": "2022-03-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:18:38.461Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26971 (GCVE-0-2022-26971)

    Vulnerability from nvd – Published: 2022-06-01 11:34 – Updated: 2024-08-03 05:18
    VLAI
    Summary
    Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. This upload can be executed without authentication.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:18:39.263Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/transform-n-management-server"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/knowledge-base/KB12681"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. This upload can be executed without authentication."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T11:34:37.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/transform-n-management-server"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/knowledge-base/KB12681"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-26971",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. This upload can be executed without authentication."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.barco.com/en/support/transform-n-management-server",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/transform-n-management-server"
                },
                {
                  "name": "https://www.barco.com/en/support/knowledge-base/KB12681",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/knowledge-base/KB12681"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-26971",
        "datePublished": "2022-06-01T11:34:37.000Z",
        "dateReserved": "2022-03-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:18:39.263Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26978 (GCVE-0-2022-26978)

    Vulnerability from cvelistv5 – Published: 2022-06-01 11:35 – Updated: 2024-08-03 05:18
    VLAI
    Summary
    Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /checklogin.jsp endpoint. The os_username parameters is not correctly sanitized, leading to reflected XSS.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:18:39.136Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/transform-n-management-server"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/knowledge-base/KB12686"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /checklogin.jsp endpoint. The os_username parameters is not correctly sanitized, leading to reflected XSS."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T11:35:22.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/transform-n-management-server"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/knowledge-base/KB12686"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-26978",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /checklogin.jsp endpoint. The os_username parameters is not correctly sanitized, leading to reflected XSS."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.barco.com/en/support/transform-n-management-server",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/transform-n-management-server"
                },
                {
                  "name": "https://www.barco.com/en/support/knowledge-base/KB12686",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/knowledge-base/KB12686"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-26978",
        "datePublished": "2022-06-01T11:35:22.000Z",
        "dateReserved": "2022-03-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:18:39.136Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26977 (GCVE-0-2022-26977)

    Vulnerability from cvelistv5 – Published: 2022-06-01 11:35 – Updated: 2024-08-03 05:18
    VLAI
    Summary
    Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization of the upload mechanism is leads to stored XSS.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:18:39.263Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/transform-n-management-server"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/knowledge-base/KB12683"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization of the upload mechanism is leads to stored XSS."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T11:35:16.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/transform-n-management-server"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/knowledge-base/KB12683"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-26977",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization of the upload mechanism is leads to stored XSS."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.barco.com/en/support/transform-n-management-server",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/transform-n-management-server"
                },
                {
                  "name": "https://www.barco.com/en/support/knowledge-base/KB12683",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/knowledge-base/KB12683"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-26977",
        "datePublished": "2022-06-01T11:35:16.000Z",
        "dateReserved": "2022-03-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:18:39.263Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26976 (GCVE-0-2022-26976)

    Vulnerability from cvelistv5 – Published: 2022-06-01 11:35 – Updated: 2024-08-03 05:18
    VLAI
    Summary
    Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization in the upload mechanism is leads to reflected XSS.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:18:39.221Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/transform-n-management-server"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/knowledge-base/KB12682"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization in the upload mechanism is leads to reflected XSS."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T11:35:06.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/transform-n-management-server"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/knowledge-base/KB12682"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-26976",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization in the upload mechanism is leads to reflected XSS."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.barco.com/en/support/transform-n-management-server",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/transform-n-management-server"
                },
                {
                  "name": "https://www.barco.com/en/support/knowledge-base/KB12682",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/knowledge-base/KB12682"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-26976",
        "datePublished": "2022-06-01T11:35:06.000Z",
        "dateReserved": "2022-03-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:18:39.221Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26975 (GCVE-0-2022-26975)

    Vulnerability from cvelistv5 – Published: 2022-06-01 11:34 – Updated: 2024-08-03 05:18
    VLAI
    Summary
    Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing log files without authentication.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:18:39.305Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/transform-n-management-server"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.barco.com/en/support/knowledge-base/KB12677"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing log files without authentication."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-01T11:34:59.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/transform-n-management-server"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.barco.com/en/support/knowledge-base/KB12677"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-26975",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing log files without authentication."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.barco.com/en/support/transform-n-management-server",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/transform-n-management-server"
                },
                {
                  "name": "https://www.barco.com/en/support/knowledge-base/KB12677",
                  "refsource": "MISC",
                  "url": "https://www.barco.com/en/support/knowledge-base/KB12677"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-26975",
        "datePublished": "2022-06-01T11:34:59.000Z",
        "dateReserved": "2022-03-12T00:00:00.000Z",
        "dateUpdated": "2024-08-03T05:18:39.305Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }