Find a vulnerability
Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
40 vulnerabilities by barco
VAR-201912-0691
Vulnerability from variot - Updated: 2024-02-13 22:58Barco ClickShare Button R9861500D01 devices before 1.10.0.13 have Missing Support for Integrity Check. The ClickShare Button does not verify the integrity of the mutable content on the UBIFS partition before being used. Barco ClickShare Button R9861500D01 The device contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. An attacker can use this vulnerability to open a backdoor to the device and present specially crafted data to the user
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201912-0691",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare button r9861500d01",
"scope": "lt",
"trust": 1.4,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare button r9861500d01",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.10.0.13"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22807"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013448"
},
{
"db": "NVD",
"id": "CVE-2019-18824"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_button_r9861500d01_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.10.0.13",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_button_r9861500d01:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18824"
}
]
},
"cve": "CVE-2019-18824",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.4,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Local",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 6.9,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2019-18824",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-22807",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.7,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Physical",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.6,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-18824",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-18824",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2020-22807",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201912-771",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2019-18824",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22807"
},
{
"db": "VULMON",
"id": "CVE-2019-18824"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013448"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-771"
},
{
"db": "NVD",
"id": "CVE-2019-18824"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 devices before 1.10.0.13 have Missing Support for Integrity Check. The ClickShare Button does not verify the integrity of the mutable content on the UBIFS partition before being used. Barco ClickShare Button R9861500D01 The device contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. An attacker can use this vulnerability to open a backdoor to the device and present specially crafted data to the user",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18824"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013448"
},
{
"db": "CNVD",
"id": "CNVD-2020-22807"
},
{
"db": "VULMON",
"id": "CVE-2019-18824"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-18824",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013448",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-22807",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201912-771",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2019-18824",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22807"
},
{
"db": "VULMON",
"id": "CVE-2019-18824"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013448"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-771"
},
{
"db": "NVD",
"id": "CVE-2019-18824"
}
]
},
"id": "VAR-201912-0691",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22807"
}
],
"trust": 1.3368421000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22807"
}
]
},
"last_update_date": "2024-02-13T22:58:47.432000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Update your ClickShare device",
"trust": 0.8,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"title": "Patch for Barco ClickShare Button R9861500D01 Input Verification Error Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/213745"
},
{
"title": "Barco ClickShare Button R9861500D01 Enter the fix for the verification error vulnerability",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105916"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22807"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013448"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-771"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-345",
"trust": 1.0
},
{
"problemtype": "CWE-20",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013448"
},
{
"db": "NVD",
"id": "CVE-2019-18824"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
},
{
"trust": 2.3,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"trust": 1.7,
"url": "https://www.barco.com/en/clickshare/support/software/r33050070?majorversion=01\u0026minorversion=10\u0026patchversion=00\u0026buildversion=013"
},
{
"trust": 1.7,
"url": "https://www.barco.com/en/clickshare/support/software/r33050069?majorversion=01\u0026minorversion=10\u0026patchversion=00\u0026buildversion=013"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-18824"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18824"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/345.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22807"
},
{
"db": "VULMON",
"id": "CVE-2019-18824"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013448"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-771"
},
{
"db": "NVD",
"id": "CVE-2019-18824"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-22807"
},
{
"db": "VULMON",
"id": "CVE-2019-18824"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013448"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-771"
},
{
"db": "NVD",
"id": "CVE-2019-18824"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-22807"
},
{
"date": "2019-12-17T00:00:00",
"db": "VULMON",
"id": "CVE-2019-18824"
},
{
"date": "2020-01-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013448"
},
{
"date": "2019-12-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-771"
},
{
"date": "2019-12-17T14:15:17.747000",
"db": "NVD",
"id": "CVE-2019-18824"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-22807"
},
{
"date": "2021-07-21T00:00:00",
"db": "VULMON",
"id": "CVE-2019-18824"
},
{
"date": "2020-01-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013448"
},
{
"date": "2020-08-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-771"
},
{
"date": "2021-07-21T11:39:23.747000",
"db": "NVD",
"id": "CVE-2019-18824"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 Vulnerability related to input validation on devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013448"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "input validation error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-771"
}
],
"trust": 0.6
}
}
VAR-201912-0693
Vulnerability from variot - Updated: 2023-12-18 13:38Barco ClickShare Button R9861500D01 devices before 1.9.0 have Improper Following of a Certificate's Chain of Trust. The embedded 'dongle_bridge' program used to expose the functionalities of the ClickShare Button to a USB host, does not properly validate the whole certificate chain. Barco ClickShare Button R9861500D01 The device contains a certificate validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Attackers can use this vulnerability to authenticate and gain access to restricted commands
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201912-0693",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare cs-100",
"scope": "lt",
"trust": 1.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200",
"scope": "lt",
"trust": 1.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-800",
"scope": "lt",
"trust": 1.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 1.2,
"vendor": "barco",
"version": null
},
{
"model": "clickshare cse-200\\+",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200+",
"scope": "lt",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare button r9861500d01",
"scope": "lt",
"trust": 0.6,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.1.0.99"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.2.1.6"
},
{
"model": "clickshare cse-200",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": null
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.8.2.2"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.7.0.22"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.6.4.4"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.2.0.47"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.7.1.1"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46447"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013803"
},
{
"db": "NVD",
"id": "CVE-2019-18826"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-724"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cs-100_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cs-100:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200\\+_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200\\+:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-800_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-800:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18826"
}
]
},
"cve": "CVE-2019-18826",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2019-18826",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-46447",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-18826",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-18826",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2019-46447",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201912-724",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46447"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013803"
},
{
"db": "NVD",
"id": "CVE-2019-18826"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-724"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 devices before 1.9.0 have Improper Following of a Certificate\u0027s Chain of Trust. The embedded \u0027dongle_bridge\u0027 program used to expose the functionalities of the ClickShare Button to a USB host, does not properly validate the whole certificate chain. Barco ClickShare Button R9861500D01 The device contains a certificate validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Attackers can use this vulnerability to authenticate and gain access to restricted commands ",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18826"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013803"
},
{
"db": "CNVD",
"id": "CNVD-2019-46447"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-18826",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013803",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2019-46447",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201912-724",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46447"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013803"
},
{
"db": "NVD",
"id": "CVE-2019-18826"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-724"
}
]
},
"id": "VAR-201912-0693",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46447"
}
],
"trust": 1.3368421000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46447"
}
]
},
"last_update_date": "2023-12-18T13:38:03.652000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Update your ClickShare device",
"trust": 0.8,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"title": "Patch for Barco ClickShare Button R9861500D01 Validation Error Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/194979"
},
{
"title": "Barco ClickShare Button R9861500D01 Repair measures for trust management problem vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105991"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46447"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013803"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-724"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-295",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013803"
},
{
"db": "NVD",
"id": "CVE-2019-18826"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.2,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-18826"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18826"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46447"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013803"
},
{
"db": "NVD",
"id": "CVE-2019-18826"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-724"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-46447"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013803"
},
{
"db": "NVD",
"id": "CVE-2019-18826"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-724"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-46447"
},
{
"date": "2020-01-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013803"
},
{
"date": "2019-12-16T17:15:11.877000",
"db": "NVD",
"id": "CVE-2019-18826"
},
{
"date": "2019-12-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-724"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-46447"
},
{
"date": "2020-01-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013803"
},
{
"date": "2019-12-27T01:14:58.913000",
"db": "NVD",
"id": "CVE-2019-18826"
},
{
"date": "2019-12-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-724"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-724"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 Device validation vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013803"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-724"
}
],
"trust": 0.6
}
}
VAR-201710-1335
Vulnerability from variot - Updated: 2023-12-18 13:24A command injection was identified on Barco ClickShare Base Unit devices with CSM-1 firmware before 1.7.0.3 and CSC-1 firmware before 1.10.0.10. An attacker with access to the product's web API can exploit this vulnerability to completely compromise the vulnerable device. BarcoClickShareCSM-1BaseUnit and ClickShareCSC-1BaseUnit are both wireless presentation system host devices from Barco, Belgium. Multiple Barco ClickShare Base Units are prone to multiple command-injection vulnerabilities because it fails to properly sanitize user-supplied input. This may aid in further attacks
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201710-1335",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare csc-1",
"scope": "lt",
"trust": 1.8,
"vendor": "barco",
"version": "1.10.0.10"
},
{
"model": "clickshare csm-1",
"scope": "lt",
"trust": 1.8,
"vendor": "barco",
"version": "1.7.0.3"
},
{
"model": "clickshare csm-1 base unit",
"scope": "lt",
"trust": 0.6,
"vendor": "barco",
"version": "1.7.0.3"
},
{
"model": "clickshare csc-1 base unit",
"scope": "lt",
"trust": 0.6,
"vendor": "barco",
"version": "1.10.0.10"
},
{
"model": "clickshare csm-1",
"scope": "eq",
"trust": 0.3,
"vendor": "barco",
"version": "1.6.4.1"
},
{
"model": "clickshare csm-1",
"scope": "eq",
"trust": 0.3,
"vendor": "barco",
"version": "1.6.3.5"
},
{
"model": "clickshare csc-1",
"scope": "eq",
"trust": 0.3,
"vendor": "barco",
"version": "1.9.5.2"
},
{
"model": "clickshare csc-1",
"scope": "eq",
"trust": 0.3,
"vendor": "barco",
"version": "1.9.4.3"
},
{
"model": "clickshare csm-1",
"scope": "ne",
"trust": 0.3,
"vendor": "barco",
"version": "1.7.0.3"
},
{
"model": "clickshare csc-1",
"scope": "ne",
"trust": 0.3,
"vendor": "barco",
"version": "1.10.0.10"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-33051"
},
{
"db": "BID",
"id": "101617"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009832"
},
{
"db": "NVD",
"id": "CVE-2017-9377"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_csm-1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.7.0.3",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_csm-1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_csc-1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.10.0.10",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_csc-1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-9377"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Claudio Moletta",
"sources": [
{
"db": "BID",
"id": "101617"
}
],
"trust": 0.3
},
"cve": "CVE-2017-9377",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2017-9377",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2017-33051",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2017-9377",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-9377",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2017-33051",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201706-171",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2017-9377",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-33051"
},
{
"db": "VULMON",
"id": "CVE-2017-9377"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009832"
},
{
"db": "NVD",
"id": "CVE-2017-9377"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-171"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A command injection was identified on Barco ClickShare Base Unit devices with CSM-1 firmware before 1.7.0.3 and CSC-1 firmware before 1.10.0.10. An attacker with access to the product\u0027s web API can exploit this vulnerability to completely compromise the vulnerable device. BarcoClickShareCSM-1BaseUnit and ClickShareCSC-1BaseUnit are both wireless presentation system host devices from Barco, Belgium. Multiple Barco ClickShare Base Units are prone to multiple command-injection vulnerabilities because it fails to properly sanitize user-supplied input. This may aid in further attacks",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-9377"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009832"
},
{
"db": "CNVD",
"id": "CNVD-2017-33051"
},
{
"db": "BID",
"id": "101617"
},
{
"db": "VULMON",
"id": "CVE-2017-9377"
}
],
"trust": 2.52
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-9377",
"trust": 3.4
},
{
"db": "BID",
"id": "101617",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009832",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2017-33051",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201706-171",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2017-9377",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-33051"
},
{
"db": "VULMON",
"id": "CVE-2017-9377"
},
{
"db": "BID",
"id": "101617"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009832"
},
{
"db": "NVD",
"id": "CVE-2017-9377"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-171"
}
]
},
"id": "VAR-201710-1335",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-33051"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-33051"
}
]
},
"last_update_date": "2023-12-18T13:24:17.942000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "ClickShare CSC-1 Base Unit Firmware v1.10.0.10",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050020"
},
{
"title": "ClickShare CSM-1 Base Unit Firmware v1.7.0.3",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050037"
},
{
"title": "Patch for BarcoClickShareCSM-1BaseUnit and ClickShareCSC-1BaseUnit command injection vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/105610"
},
{
"title": "Barco ClickShare CSM-1 Base Unit and ClickShare CSC-1 Base Unit Fixes for command injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=99842"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-33051"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009832"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-171"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.0
},
{
"problemtype": "CWE-77",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-009832"
},
{
"db": "NVD",
"id": "CVE-2017-9377"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://www.barco.com/en/support/software/r33050020"
},
{
"trust": 2.0,
"url": "https://www.barco.com/en/support/software/r33050037"
},
{
"trust": 2.0,
"url": "https://www.contextis.com/resources/advisories/cve-2017-9377"
},
{
"trust": 1.8,
"url": "http://www.securityfocus.com/bid/101617"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9377"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-9377"
},
{
"trust": 0.3,
"url": "https://www.barco.com/en/clickshare"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-33051"
},
{
"db": "VULMON",
"id": "CVE-2017-9377"
},
{
"db": "BID",
"id": "101617"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009832"
},
{
"db": "NVD",
"id": "CVE-2017-9377"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-171"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2017-33051"
},
{
"db": "VULMON",
"id": "CVE-2017-9377"
},
{
"db": "BID",
"id": "101617"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009832"
},
{
"db": "NVD",
"id": "CVE-2017-9377"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-171"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-11-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-33051"
},
{
"date": "2017-10-30T00:00:00",
"db": "VULMON",
"id": "CVE-2017-9377"
},
{
"date": "2017-09-27T00:00:00",
"db": "BID",
"id": "101617"
},
{
"date": "2017-11-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-009832"
},
{
"date": "2017-10-30T14:29:00.923000",
"db": "NVD",
"id": "CVE-2017-9377"
},
{
"date": "2017-06-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201706-171"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-11-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-33051"
},
{
"date": "2019-10-03T00:00:00",
"db": "VULMON",
"id": "CVE-2017-9377"
},
{
"date": "2017-12-19T21:00:00",
"db": "BID",
"id": "101617"
},
{
"date": "2017-11-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-009832"
},
{
"date": "2019-10-03T00:03:26.223000",
"db": "NVD",
"id": "CVE-2017-9377"
},
{
"date": "2019-10-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201706-171"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201706-171"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare CSM-1 Base Unit and ClickShare CSC-1 Base Unit Command Injection Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-33051"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-171"
}
],
"trust": 1.2
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201706-171"
}
],
"trust": 0.6
}
}
VAR-201912-0684
Vulnerability from variot - Updated: 2023-12-18 13:07Barco ClickShare Button R9861500D01 devices before 1.9.0 allow Information exposure (issue 2 of 2).. The encryption key of the media content which is shared between a ClickShare Button and a ClickShare Base Unit is randomly generated for each new session and communicated over a TLS connection. An attacker who is able to perform a Man-in-the-Middle attack between the TLS connection, is able to obtain the encryption key. Barco ClickShare Button R9861500D01 The device contains a vulnerability related to the lack of encryption of critical data.Information may be obtained. Barco ClickShare Button R9861500D01 is a wireless control device for the demonstration system of Barco, Belgium
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201912-0684",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare button r9861500d01",
"scope": "lt",
"trust": 2.4,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare button r9861500d01",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46252"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013452"
},
{
"db": "NVD",
"id": "CVE-2019-18833"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-776"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_button_r9861500d01_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_button_r9861500d01:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18833"
}
]
},
"cve": "CVE-2019-18833",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.3,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2019-18833",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-46252",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "High",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.9,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-18833",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-18833",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2019-46252",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201912-776",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46252"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013452"
},
{
"db": "NVD",
"id": "CVE-2019-18833"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-776"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 devices before 1.9.0 allow Information exposure (issue 2 of 2).. The encryption key of the media content which is shared between a ClickShare Button and a ClickShare Base Unit is randomly generated for each new session and communicated over a TLS connection. An attacker who is able to perform a Man-in-the-Middle attack between the TLS connection, is able to obtain the encryption key. Barco ClickShare Button R9861500D01 The device contains a vulnerability related to the lack of encryption of critical data.Information may be obtained. Barco ClickShare Button R9861500D01 is a wireless control device for the demonstration system of Barco, Belgium",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18833"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013452"
},
{
"db": "CNVD",
"id": "CNVD-2019-46252"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-18833",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013452",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2019-46252",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201912-776",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46252"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013452"
},
{
"db": "NVD",
"id": "CVE-2019-18833"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-776"
}
]
},
"id": "VAR-201912-0684",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46252"
}
],
"trust": 1.3368421000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46252"
}
]
},
"last_update_date": "2023-12-18T13:07:48.389000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Update your ClickShare device",
"trust": 0.8,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"title": "Patch for Barco ClickShare Button R9861500D01 Key Disclosure Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/194663"
},
{
"title": "Barco ClickShare Button R9861500D01 Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105920"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46252"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013452"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-776"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-311",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013452"
},
{
"db": "NVD",
"id": "CVE-2019-18833"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-18833"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18833"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46252"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013452"
},
{
"db": "NVD",
"id": "CVE-2019-18833"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-776"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-46252"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013452"
},
{
"db": "NVD",
"id": "CVE-2019-18833"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-776"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-46252"
},
{
"date": "2020-01-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013452"
},
{
"date": "2019-12-17T14:15:18.030000",
"db": "NVD",
"id": "CVE-2019-18833"
},
{
"date": "2019-12-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-776"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-46252"
},
{
"date": "2020-01-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013452"
},
{
"date": "2019-12-26T15:24:20.467000",
"db": "NVD",
"id": "CVE-2019-18833"
},
{
"date": "2019-12-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-776"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-776"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 Vulnerability related to lack of encryption of critical data on devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013452"
}
],
"trust": 0.8
}
}
VAR-201912-0680
Vulnerability from variot - Updated: 2023-12-18 13:01Barco ClickShare Button R9861500D01 devices before 1.10.0.13 have Missing Support for Integrity Check. The Barco signed 'Clickshare_For_Windows.exe' binary on the ClickShare Button (R9861500D01) loads a number of DLL files dynamically without verifying their integrity. Barco ClickShare Button R9861500D01 The device contains an untrusted search path vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Attackers can use this vulnerability to inject arbitrary code
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201912-0680",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare button r9861500d01",
"scope": "lt",
"trust": 1.4,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare button r9861500d01",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.10.0.13"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22684"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013450"
},
{
"db": "NVD",
"id": "CVE-2019-18829"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_button_r9861500d01_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.10.0.13",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_button_r9861500d01:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18829"
}
]
},
"cve": "CVE-2019-18829",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.4,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Local",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 4.4,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2019-18829",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2020-22684",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-18829",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-18829",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2020-22684",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201912-773",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22684"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013450"
},
{
"db": "NVD",
"id": "CVE-2019-18829"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-773"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 devices before 1.10.0.13 have Missing Support for Integrity Check. The Barco signed \u0027Clickshare_For_Windows.exe\u0027 binary on the ClickShare Button (R9861500D01) loads a number of DLL files dynamically without verifying their integrity. Barco ClickShare Button R9861500D01 The device contains an untrusted search path vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Attackers can use this vulnerability to inject arbitrary code",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18829"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013450"
},
{
"db": "CNVD",
"id": "CNVD-2020-22684"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-18829",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013450",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-22684",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201912-773",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22684"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013450"
},
{
"db": "NVD",
"id": "CVE-2019-18829"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-773"
}
]
},
"id": "VAR-201912-0680",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22684"
}
],
"trust": 1.3368421000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22684"
}
]
},
"last_update_date": "2023-12-18T13:01:57.457000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Update your ClickShare device",
"trust": 0.8,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"title": "Patch for Barco ClickShare Button R9861500D01 code issue vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/213719"
},
{
"title": "Barco ClickShare Button R9861500D01 Fixes for code issue vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105918"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22684"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013450"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-773"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-345",
"trust": 1.0
},
{
"problemtype": "CWE-426",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013450"
},
{
"db": "NVD",
"id": "CVE-2019-18829"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
},
{
"trust": 2.2,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/clickshare/support/software/r33050069?majorversion=01\u0026minorversion=10\u0026patchversion=00\u0026buildversion=013"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/clickshare/support/software/r33050070?majorversion=01\u0026minorversion=10\u0026patchversion=00\u0026buildversion=013"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-18829"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18829"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22684"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013450"
},
{
"db": "NVD",
"id": "CVE-2019-18829"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-773"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-22684"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013450"
},
{
"db": "NVD",
"id": "CVE-2019-18829"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-773"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-22684"
},
{
"date": "2020-01-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013450"
},
{
"date": "2019-12-17T14:15:17.903000",
"db": "NVD",
"id": "CVE-2019-18829"
},
{
"date": "2019-12-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-773"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-22684"
},
{
"date": "2020-01-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013450"
},
{
"date": "2021-07-21T11:39:23.747000",
"db": "NVD",
"id": "CVE-2019-18829"
},
{
"date": "2020-08-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-773"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-773"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 Unreliable search path vulnerability in device",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013450"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "code problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-773"
}
],
"trust": 0.6
}
}
VAR-201912-0682
Vulnerability from variot - Updated: 2023-12-18 12:56Barco ClickShare Button R9861500D01 devices before 1.9.0 allow Information Exposure. The encrypted ClickShare Button firmware contains the private key of a test device-certificate. Attackers can use this vulnerability to disclose information
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201912-0682",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare cse-200",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200\\+",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-800",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cs-100",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cs-100",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200+",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare button r9861500d01",
"scope": "lt",
"trust": 0.6,
"vendor": "barco",
"version": "1.9.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46448"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013420"
},
{
"db": "NVD",
"id": "CVE-2019-18831"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cs-100_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cs-100:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200\\+_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200\\+:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-800_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-800:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18831"
}
]
},
"cve": "CVE-2019-18831",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "LOW",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:M/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 3.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2019-18831",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Low",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-46448",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.6,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "High",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.3,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-18831",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-18831",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2019-46448",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201912-726",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46448"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013420"
},
{
"db": "NVD",
"id": "CVE-2019-18831"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-726"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 devices before 1.9.0 allow Information Exposure. The encrypted ClickShare Button firmware contains the private key of a test device-certificate. Attackers can use this vulnerability to disclose information",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18831"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013420"
},
{
"db": "CNVD",
"id": "CNVD-2019-46448"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-18831",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013420",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2019-46448",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201912-726",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46448"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013420"
},
{
"db": "NVD",
"id": "CVE-2019-18831"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-726"
}
]
},
"id": "VAR-201912-0682",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46448"
}
],
"trust": 1.3368421000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46448"
}
]
},
"last_update_date": "2023-12-18T12:56:18.506000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "ClickShare",
"trust": 0.8,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"title": "ClickShare CS-100 base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "ClickShare CSE-200 base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "ClickShare CSE-800 base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "ClickShare CSE-200+ base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "Patch for Barco ClickShare Button R9861500D01 Information Disclosure Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/194985"
},
{
"title": "Barco ClickShare Button R9861500D01 Repair measures for information disclosure vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105749"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46448"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013420"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-726"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.0
},
{
"problemtype": "CWE-200",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013420"
},
{
"db": "NVD",
"id": "CVE-2019-18831"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.2,
"url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
},
{
"trust": 2.2,
"url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-18831"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18831"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46448"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013420"
},
{
"db": "NVD",
"id": "CVE-2019-18831"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-726"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-46448"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013420"
},
{
"db": "NVD",
"id": "CVE-2019-18831"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-726"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-46448"
},
{
"date": "2019-12-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013420"
},
{
"date": "2019-12-16T17:15:12.177000",
"db": "NVD",
"id": "CVE-2019-18831"
},
{
"date": "2019-12-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-726"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-46448"
},
{
"date": "2019-12-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013420"
},
{
"date": "2020-08-24T17:37:01.140000",
"db": "NVD",
"id": "CVE-2019-18831"
},
{
"date": "2020-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-726"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-726"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button Information disclosure vulnerability in devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013420"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-726"
}
],
"trust": 0.6
}
}
VAR-201912-0681
Vulnerability from variot - Updated: 2023-12-18 12:35Barco ClickShare Button R9861500D01 devices before 1.9.0 allow OS Command Injection. The embedded 'dongle_bridge' program used to expose the functionalities of the ClickShare Button to a USB host, is vulnerable to OS command injection vulnerabilities. These vulnerabilities could lead to code execution on the ClickShare Button with the privileges of the user 'nobody'. Barco ClickShare Button The device includes OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Barco ClickShare Button R9861500D01 is a wireless control device for the demonstration system of Barco, Belgium.
Barco ClickShare Button R9861500D01 The Dongle_bridge program embedded in versions earlier than 1.9.0 has an operating system command injection vulnerability, which originates from the process of externally inputting data to construct operating system executable commands, and the network system or product did not properly filter the special characters and commands. The attacker can use this vulnerability to execute illegal operating system commands
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201912-0681",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare cse-200",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200\\+",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-800",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cs-100",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cs-100",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200+",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare button r9861500d01",
"scope": "lt",
"trust": 0.6,
"vendor": "barco",
"version": "1.9.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46446"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013419"
},
{
"db": "NVD",
"id": "CVE-2019-18830"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cs-100_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cs-100:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200\\+_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200\\+:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-800_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-800:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18830"
}
]
},
"cve": "CVE-2019-18830",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2019-18830",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-46446",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-18830",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-18830",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2019-46446",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201912-720",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2019-18830",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46446"
},
{
"db": "VULMON",
"id": "CVE-2019-18830"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013419"
},
{
"db": "NVD",
"id": "CVE-2019-18830"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-720"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 devices before 1.9.0 allow OS Command Injection. The embedded \u0027dongle_bridge\u0027 program used to expose the functionalities of the ClickShare Button to a USB host, is vulnerable to OS command injection vulnerabilities. These vulnerabilities could lead to code execution on the ClickShare Button with the privileges of the user \u0027nobody\u0027. Barco ClickShare Button The device includes OS A command injection vulnerability exists.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Barco ClickShare Button R9861500D01 is a wireless control device for the demonstration system of Barco, Belgium. \n\nBarco ClickShare Button R9861500D01 The Dongle_bridge program embedded in versions earlier than 1.9.0 has an operating system command injection vulnerability, which originates from the process of externally inputting data to construct operating system executable commands, and the network system or product did not properly filter the special characters and commands. The attacker can use this vulnerability to execute illegal operating system commands",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18830"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013419"
},
{
"db": "CNVD",
"id": "CNVD-2019-46446"
},
{
"db": "VULMON",
"id": "CVE-2019-18830"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-18830",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013419",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2019-46446",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201912-720",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2019-18830",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46446"
},
{
"db": "VULMON",
"id": "CVE-2019-18830"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013419"
},
{
"db": "NVD",
"id": "CVE-2019-18830"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-720"
}
]
},
"id": "VAR-201912-0681",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46446"
}
],
"trust": 1.3368421000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46446"
}
]
},
"last_update_date": "2023-12-18T12:35:53.659000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "ClickShare",
"trust": 0.8,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"title": "ClickShare CS-100 base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "ClickShare CSE-200 base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "ClickShare CSE-800 base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "ClickShare CSE-200+ base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "Patch for Barco ClickShare Button R9861500D01 Operating System Command Injection Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/194973"
},
{
"title": "Barco ClickShare Button R9861500D01 Fixes for operating system command injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105748"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46446"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013419"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-720"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013419"
},
{
"db": "NVD",
"id": "CVE-2019-18830"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-18830"
},
{
"trust": 1.7,
"url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 1.7,
"url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
},
{
"trust": 1.7,
"url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 1.7,
"url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 1.7,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18830"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46446"
},
{
"db": "VULMON",
"id": "CVE-2019-18830"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013419"
},
{
"db": "NVD",
"id": "CVE-2019-18830"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-720"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-46446"
},
{
"db": "VULMON",
"id": "CVE-2019-18830"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013419"
},
{
"db": "NVD",
"id": "CVE-2019-18830"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-720"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-46446"
},
{
"date": "2019-12-16T00:00:00",
"db": "VULMON",
"id": "CVE-2019-18830"
},
{
"date": "2019-12-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013419"
},
{
"date": "2019-12-16T17:15:12.080000",
"db": "NVD",
"id": "CVE-2019-18830"
},
{
"date": "2019-12-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-720"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-46446"
},
{
"date": "2019-12-23T00:00:00",
"db": "VULMON",
"id": "CVE-2019-18830"
},
{
"date": "2019-12-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013419"
},
{
"date": "2019-12-23T18:11:44.480000",
"db": "NVD",
"id": "CVE-2019-18830"
},
{
"date": "2020-06-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-720"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-720"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 Operating System Command Injection Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46446"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-720"
}
],
"trust": 1.2
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-720"
}
],
"trust": 0.6
}
}
VAR-201912-0683
Vulnerability from variot - Updated: 2023-12-18 12:35Barco ClickShare Button R9861500D01 devices before 1.9.0 have incorrect Credentials Management. The ClickShare Button implements encryption at rest which uses a one-time programmable (OTP) AES encryption key. This key is shared across all ClickShare Buttons of model R9861500D01. Barco ClickShare Button R9861500D01 The device contains a vulnerability related to information disclosure from the cache.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Attackers could use this vulnerability to forge arbitrary software images
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201912-0683",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare button r9861500d01",
"scope": "lt",
"trust": 2.4,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare button r9861500d01",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-10435"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013451"
},
{
"db": "NVD",
"id": "CVE-2019-18832"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-775"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_button_r9861500d01_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_button_r9861500d01:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18832"
}
]
},
"cve": "CVE-2019-18832",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.8,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2019-18832",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CNVD-2020-10435",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "High",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.1,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-18832",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-18832",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2020-10435",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201912-775",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-10435"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013451"
},
{
"db": "NVD",
"id": "CVE-2019-18832"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-775"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 devices before 1.9.0 have incorrect Credentials Management. The ClickShare Button implements encryption at rest which uses a one-time programmable (OTP) AES encryption key. This key is shared across all ClickShare Buttons of model R9861500D01. Barco ClickShare Button R9861500D01 The device contains a vulnerability related to information disclosure from the cache.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Attackers could use this vulnerability to forge arbitrary software images",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18832"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013451"
},
{
"db": "CNVD",
"id": "CNVD-2020-10435"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-18832",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013451",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-10435",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201912-775",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-10435"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013451"
},
{
"db": "NVD",
"id": "CVE-2019-18832"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-775"
}
]
},
"id": "VAR-201912-0683",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-10435"
}
],
"trust": 1.3368421000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-10435"
}
]
},
"last_update_date": "2023-12-18T12:35:53.633000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Update your ClickShare device",
"trust": 0.8,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"title": "Patch for Barco ClickShare Button R9861500D01 Credential Management Error Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/201823"
},
{
"title": "Barco ClickShare Button R9861500D01 Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105919"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-10435"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013451"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-775"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-327",
"trust": 1.0
},
{
"problemtype": "CWE-522",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013451"
},
{
"db": "NVD",
"id": "CVE-2019-18832"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-18832"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18832"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-10435"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013451"
},
{
"db": "NVD",
"id": "CVE-2019-18832"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-775"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-10435"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013451"
},
{
"db": "NVD",
"id": "CVE-2019-18832"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-775"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-02-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-10435"
},
{
"date": "2020-01-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013451"
},
{
"date": "2019-12-17T14:15:17.967000",
"db": "NVD",
"id": "CVE-2019-18832"
},
{
"date": "2019-12-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-775"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-02-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-10435"
},
{
"date": "2020-01-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013451"
},
{
"date": "2021-07-21T11:39:23.747000",
"db": "NVD",
"id": "CVE-2019-18832"
},
{
"date": "2019-12-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-775"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-775"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 Vulnerability related to information leak from cache in device",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013451"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-775"
}
],
"trust": 0.6
}
}
VAR-201701-0402
Vulnerability from variot - Updated: 2023-12-18 12:29Cross-site scripting (XSS) vulnerability in wallpaper.php in the Base Unit in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. Barco ClickShare is prone to a cross-site scripting vulnerability and a directory-traversal vulnerability because it fails to sufficiently sanitize user-supplied input. A remote attacker can leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site and to view arbitrary local files and directories within the context of the webserver. This may let the attacker steal cookie-based authentication credentials and gain access to sensitive information, which may aid in launching further attacks. Versions prior to Barco ClickShare 01.09.03, 01.06.02 and 01.03.02 are vulnerable. Barco ClickShare CSC-1 is a wireless presentation system from Barco, Belgium. Base Unit is one of the basic integration kits. The following devices are affected: Barco ClickShare CSC-1 devices with firmware prior to 01.09.03; CSM-1 devices with firmware prior to 01.06.02; CSE-200 devices with firmware prior to 01.03.02. A Path Traversal vulnerability exists within Barco ClickShare's wallpaper parsing functionality, which leads to disclosure of the /etc/shadow file on the file system.
CVE-2016-3152 - /etc/shadow file disclosure in the CSC-1 firmware update Affected versions: all versions prior to v01.09.03 (CSC-1) It is possible to download and extract the firmware image of the CSC-1 and obtain the root password.
The vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance.
References: http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020&rev=001002000009 http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037&rev=001001000113 https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070&rev=001001000008
--
Regards,
Vincent Ruijter Ethical Hacker Chief Information Security Office KPN B.V
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201701-0402",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare csc-1",
"scope": "lte",
"trust": 1.0,
"vendor": "barco",
"version": "01.09.05.02"
},
{
"model": "clickshare cse-200",
"scope": "lte",
"trust": 1.0,
"vendor": "barco",
"version": "01.09.02.05"
},
{
"model": "clickshare csc-1",
"scope": null,
"trust": 0.8,
"vendor": "barco",
"version": null
},
{
"model": "clickshare csc-1",
"scope": "lt",
"trust": 0.8,
"vendor": "barco",
"version": "01.09.03"
},
{
"model": "clickshare cse-200",
"scope": null,
"trust": 0.8,
"vendor": "barco",
"version": null
},
{
"model": "clickshare cse-200",
"scope": "lt",
"trust": 0.8,
"vendor": "barco",
"version": "01.03.02"
},
{
"model": "clickshare csm-1",
"scope": null,
"trust": 0.8,
"vendor": "barco",
"version": null
},
{
"model": "clickshare csm-1",
"scope": "lt",
"trust": 0.8,
"vendor": "barco",
"version": "01.06.02"
},
{
"model": "clickshare csc-1",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "01.09.05.02"
},
{
"model": "clickshare cse-200",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "01.09.02.05"
},
{
"model": "clickshare",
"scope": "eq",
"trust": 0.3,
"vendor": "barco",
"version": "1.9.2"
},
{
"model": "clickshare",
"scope": "eq",
"trust": 0.3,
"vendor": "barco",
"version": "1.6.1"
},
{
"model": "clickshare",
"scope": "eq",
"trust": 0.3,
"vendor": "barco",
"version": "1.3.1"
},
{
"model": "clickshare",
"scope": "ne",
"trust": 0.3,
"vendor": "barco",
"version": "1.9.3"
},
{
"model": "clickshare",
"scope": "ne",
"trust": 0.3,
"vendor": "barco",
"version": "1.6.2"
},
{
"model": "clickshare",
"scope": "ne",
"trust": 0.3,
"vendor": "barco",
"version": "1.3.2"
}
],
"sources": [
{
"db": "BID",
"id": "94330"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006880"
},
{
"db": "NVD",
"id": "CVE-2016-3150"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-538"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_csc-1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "01.09.05.02",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_csc-1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "01.09.02.05",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2016-3150"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vincent Ruijter",
"sources": [
{
"db": "BID",
"id": "94330"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-538"
}
],
"trust": 1.0
},
"cve": "CVE-2016-3150",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.3,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2016-3150",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "VHN-91969",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 6.1,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2016-3150",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2016-3150",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201611-538",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-91969",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91969"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006880"
},
{
"db": "NVD",
"id": "CVE-2016-3150"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-538"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cross-site scripting (XSS) vulnerability in wallpaper.php in the Base Unit in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. Barco ClickShare is prone to a cross-site scripting vulnerability and a directory-traversal vulnerability because it fails to sufficiently sanitize user-supplied input. \nA remote attacker can leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site and to view arbitrary local files and directories within the context of the webserver. This may let the attacker steal cookie-based authentication credentials and gain access to sensitive information, which may aid in launching further attacks. \nVersions prior to Barco ClickShare 01.09.03, 01.06.02 and 01.03.02 are vulnerable. Barco ClickShare CSC-1 is a wireless presentation system from Barco, Belgium. Base Unit is one of the basic integration kits. The following devices are affected: Barco ClickShare CSC-1 devices with firmware prior to 01.09.03; CSM-1 devices with firmware prior to 01.06.02; CSE-200 devices with firmware prior to 01.03.02. \nA Path Traversal vulnerability exists within Barco ClickShare\u0027s wallpaper parsing functionality, which leads to disclosure of the /etc/shadow file on the file system. \n\nCVE-2016-3152 - /etc/shadow file disclosure in the CSC-1 firmware update\nAffected versions: all versions prior to v01.09.03 (CSC-1)\nIt is possible to download and extract the firmware image of the CSC-1 and obtain the root password. \n\nThe vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance. \n\nReferences:\nhttp://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020\u0026rev=001002000009\nhttp://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037\u0026rev=001001000113\nhttps://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070\u0026rev=001001000008\n\n--\n\nRegards,\n\nVincent Ruijter\nEthical Hacker\nChief Information Security Office\nKPN B.V",
"sources": [
{
"db": "NVD",
"id": "CVE-2016-3150"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006880"
},
{
"db": "BID",
"id": "94330"
},
{
"db": "VULHUB",
"id": "VHN-91969"
},
{
"db": "PACKETSTORM",
"id": "139713"
}
],
"trust": 2.07
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2016-3150",
"trust": 2.9
},
{
"db": "PACKETSTORM",
"id": "139713",
"trust": 2.6
},
{
"db": "BID",
"id": "94330",
"trust": 2.0
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006880",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201611-538",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-91969",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91969"
},
{
"db": "BID",
"id": "94330"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006880"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "NVD",
"id": "CVE-2016-3150"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-538"
}
]
},
"id": "VAR-201701-0402",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-91969"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T12:29:52.408000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Update your ClickShare firmware",
"trust": 0.8,
"url": "https://www.barco.com/en/page/update-your-clickshare-firmware"
},
{
"title": "Barco ClickShare Fixes for cross-site scripting vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=65873"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-006880"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-538"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91969"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006880"
},
{
"db": "NVD",
"id": "CVE-2016-3150"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "http://packetstormsecurity.com/files/139713/barco-clickshare-xss-remote-code-execution-path-traversal.html"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/94330"
},
{
"trust": 1.1,
"url": "http://www.securityfocus.com/archive/1/539754/100/0/threaded"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-3150"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-3150"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/archive/1/archive/1/539754/100/0/threaded"
},
{
"trust": 0.3,
"url": "https://www.barco.com/en/clickshare"
},
{
"trust": 0.3,
"url": "http://seclists.org/bugtraq/2016/nov/49"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3149"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3151"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3152"
},
{
"trust": 0.1,
"url": "http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050037\u0026rev=001001000113"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3150"
},
{
"trust": 0.1,
"url": "http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=r33050020\u0026rev=001002000009"
},
{
"trust": 0.1,
"url": "https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050070\u0026rev=001001000008"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91969"
},
{
"db": "BID",
"id": "94330"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006880"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "NVD",
"id": "CVE-2016-3150"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-538"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-91969"
},
{
"db": "BID",
"id": "94330"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006880"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "NVD",
"id": "CVE-2016-3150"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-538"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-01-12T00:00:00",
"db": "VULHUB",
"id": "VHN-91969"
},
{
"date": "2016-11-14T00:00:00",
"db": "BID",
"id": "94330"
},
{
"date": "2017-01-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-006880"
},
{
"date": "2016-11-14T17:07:07",
"db": "PACKETSTORM",
"id": "139713"
},
{
"date": "2017-01-12T23:59:00.307000",
"db": "NVD",
"id": "CVE-2016-3150"
},
{
"date": "2016-11-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201611-538"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-91969"
},
{
"date": "2016-11-24T01:10:00",
"db": "BID",
"id": "94330"
},
{
"date": "2017-01-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-006880"
},
{
"date": "2018-10-09T19:59:47.147000",
"db": "NVD",
"id": "CVE-2016-3150"
},
{
"date": "2017-01-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201611-538"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-538"
}
],
"trust": 0.7
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Barco ClickShare Device product firmware Base Unit of wallpaper.php Vulnerable to cross-site scripting",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-006880"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201611-538"
}
],
"trust": 0.6
}
}
VAR-201701-0401
Vulnerability from variot - Updated: 2023-12-18 12:29Barco ClickShare CSC-1 devices with firmware before 01.09.03 and CSM-1 devices with firmware before 01.06.02 allow remote attackers to execute arbitrary code via unspecified vectors. Barco ClickShare is prone to a remote code-execution vulnerability. Failed exploit attempts may cause a denial-of-service condition. Versions prior to Barco ClickShare 01.09.03 and 01.06.02 are vulnerable. Barco ClickShare CSC-1 etc. are wireless presentation systems of Belgium Barco (Barco).
CVE-2016-3150 - Cross-site Scripting in Barco ClickShare CSC-1, CSM-1 and CSE-200 Affected versions: all versions prior to v01.09.03 (CSC-1), v01.06.02 (CSM-1) and v01.03.02 (CSE-200) A Cross-Site Scripting vulnerability exists within Barco ClickShare's CSC-1 base unit's wallpaper.php due to invalid input and output sanitisation. A Path Traversal vulnerability exists within Barco ClickShare's wallpaper parsing functionality, which leads to disclosure of the /etc/shadow file on the file system.
CVE-2016-3152 - /etc/shadow file disclosure in the CSC-1 firmware update Affected versions: all versions prior to v01.09.03 (CSC-1) It is possible to download and extract the firmware image of the CSC-1 and obtain the root password.
The vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance.
References: http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020&rev=001002000009 http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037&rev=001001000113 https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070&rev=001001000008
--
Regards,
Vincent Ruijter Ethical Hacker Chief Information Security Office KPN B.V
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201701-0401",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare csm-1",
"scope": "lte",
"trust": 1.0,
"vendor": "barco",
"version": "01.06.01.04"
},
{
"model": "clickshare csc-1",
"scope": "lte",
"trust": 1.0,
"vendor": "barco",
"version": "01.09.02.03"
},
{
"model": "clickshare csc-1",
"scope": null,
"trust": 0.8,
"vendor": "barco",
"version": null
},
{
"model": "clickshare csc-1",
"scope": "lt",
"trust": 0.8,
"vendor": "barco",
"version": "01.09.03"
},
{
"model": "clickshare csm-1",
"scope": null,
"trust": 0.8,
"vendor": "barco",
"version": null
},
{
"model": "clickshare csm-1",
"scope": "lt",
"trust": 0.8,
"vendor": "barco",
"version": "01.06.02"
},
{
"model": "clickshare csm-1",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "01.06.01.04"
},
{
"model": "clickshare csc-1",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "01.09.02.03"
},
{
"model": "clickshare",
"scope": "eq",
"trust": 0.3,
"vendor": "barco",
"version": "1.9.2"
},
{
"model": "clickshare",
"scope": "eq",
"trust": 0.3,
"vendor": "barco",
"version": "1.6.1"
},
{
"model": "clickshare",
"scope": "ne",
"trust": 0.3,
"vendor": "barco",
"version": "1.9.3"
},
{
"model": "clickshare",
"scope": "ne",
"trust": 0.3,
"vendor": "barco",
"version": "1.6.2"
}
],
"sources": [
{
"db": "BID",
"id": "94323"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006879"
},
{
"db": "NVD",
"id": "CVE-2016-3149"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-540"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_csc-1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "01.09.02.03",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_csc-1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_csm-1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "01.06.01.04",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_csm-1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2016-3149"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vincent Ruijter",
"sources": [
{
"db": "BID",
"id": "94323"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-540"
}
],
"trust": 1.0
},
"cve": "CVE-2016-3149",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": true,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2016-3149",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-91968",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2016-3149",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2016-3149",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-201611-540",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-91968",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2016-3149",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91968"
},
{
"db": "VULMON",
"id": "CVE-2016-3149"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006879"
},
{
"db": "NVD",
"id": "CVE-2016-3149"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-540"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare CSC-1 devices with firmware before 01.09.03 and CSM-1 devices with firmware before 01.06.02 allow remote attackers to execute arbitrary code via unspecified vectors. Barco ClickShare is prone to a remote code-execution vulnerability. Failed exploit attempts may cause a denial-of-service condition. \nVersions prior to Barco ClickShare 01.09.03 and 01.06.02 are vulnerable. Barco ClickShare CSC-1 etc. are wireless presentation systems of Belgium Barco (Barco). \n\nCVE-2016-3150 - Cross-site Scripting in Barco ClickShare CSC-1, CSM-1 and CSE-200\nAffected versions: all versions prior to v01.09.03 (CSC-1), v01.06.02 (CSM-1) and v01.03.02 (CSE-200)\nA Cross-Site Scripting vulnerability exists within Barco ClickShare\u0027s CSC-1 base unit\u0027s wallpaper.php due to invalid input and output sanitisation. \nA Path Traversal vulnerability exists within Barco ClickShare\u0027s wallpaper parsing functionality, which leads to disclosure of the /etc/shadow file on the file system. \n\nCVE-2016-3152 - /etc/shadow file disclosure in the CSC-1 firmware update\nAffected versions: all versions prior to v01.09.03 (CSC-1)\nIt is possible to download and extract the firmware image of the CSC-1 and obtain the root password. \n\nThe vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance. \n\nReferences:\nhttp://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020\u0026rev=001002000009\nhttp://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037\u0026rev=001001000113\nhttps://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070\u0026rev=001001000008\n\n--\n\nRegards,\n\nVincent Ruijter\nEthical Hacker\nChief Information Security Office\nKPN B.V",
"sources": [
{
"db": "NVD",
"id": "CVE-2016-3149"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006879"
},
{
"db": "BID",
"id": "94323"
},
{
"db": "VULHUB",
"id": "VHN-91968"
},
{
"db": "VULMON",
"id": "CVE-2016-3149"
},
{
"db": "PACKETSTORM",
"id": "139713"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2016-3149",
"trust": 3.0
},
{
"db": "PACKETSTORM",
"id": "139713",
"trust": 2.7
},
{
"db": "BID",
"id": "94323",
"trust": 2.1
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006879",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201611-540",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-91968",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2016-3149",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91968"
},
{
"db": "VULMON",
"id": "CVE-2016-3149"
},
{
"db": "BID",
"id": "94323"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006879"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "NVD",
"id": "CVE-2016-3149"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-540"
}
]
},
"id": "VAR-201701-0401",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-91968"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T12:29:52.373000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Update your ClickShare firmware",
"trust": 0.8,
"url": "https://www.barco.com/en/page/update-your-clickshare-firmware"
},
{
"title": "Barco ClickShare Fixes for remote code execution vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=65875"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-006879"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-540"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2016-3149"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "http://packetstormsecurity.com/files/139713/barco-clickshare-xss-remote-code-execution-path-traversal.html"
},
{
"trust": 1.9,
"url": "http://www.securityfocus.com/bid/94323"
},
{
"trust": 1.2,
"url": "http://www.securityfocus.com/archive/1/539754/100/0/threaded"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-3149"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-3149"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/archive/1/archive/1/539754/100/0/threaded"
},
{
"trust": 0.3,
"url": "https://www.barco.com/en/clickshare"
},
{
"trust": 0.3,
"url": "http://seclists.org/bugtraq/2016/nov/49"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3149"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3151"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3152"
},
{
"trust": 0.1,
"url": "http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050037\u0026rev=001001000113"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3150"
},
{
"trust": 0.1,
"url": "http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=r33050020\u0026rev=001002000009"
},
{
"trust": 0.1,
"url": "https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050070\u0026rev=001001000008"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91968"
},
{
"db": "VULMON",
"id": "CVE-2016-3149"
},
{
"db": "BID",
"id": "94323"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006879"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "NVD",
"id": "CVE-2016-3149"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-540"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-91968"
},
{
"db": "VULMON",
"id": "CVE-2016-3149"
},
{
"db": "BID",
"id": "94323"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006879"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "NVD",
"id": "CVE-2016-3149"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-540"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-01-12T00:00:00",
"db": "VULHUB",
"id": "VHN-91968"
},
{
"date": "2017-01-12T00:00:00",
"db": "VULMON",
"id": "CVE-2016-3149"
},
{
"date": "2016-11-14T00:00:00",
"db": "BID",
"id": "94323"
},
{
"date": "2017-01-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-006879"
},
{
"date": "2016-11-14T17:07:07",
"db": "PACKETSTORM",
"id": "139713"
},
{
"date": "2017-01-12T23:59:00.260000",
"db": "NVD",
"id": "CVE-2016-3149"
},
{
"date": "2016-11-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201611-540"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-91968"
},
{
"date": "2018-10-09T00:00:00",
"db": "VULMON",
"id": "CVE-2016-3149"
},
{
"date": "2016-11-24T00:10:00",
"db": "BID",
"id": "94323"
},
{
"date": "2017-01-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-006879"
},
{
"date": "2018-10-09T19:59:46.817000",
"db": "NVD",
"id": "CVE-2016-3149"
},
{
"date": "2017-01-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201611-540"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-540"
}
],
"trust": 0.7
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare CSC-1 and CSM-1 Vulnerability to execute arbitrary code in device firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-006879"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "lack of information",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201611-540"
}
],
"trust": 0.6
}
}
VAR-201701-0403
Vulnerability from variot - Updated: 2023-12-18 12:29Directory traversal vulnerability in the wallpaper parsing functionality in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to read /etc/shadow via unspecified vectors. Barco ClickShare is prone to a cross-site scripting vulnerability and a directory-traversal vulnerability because it fails to sufficiently sanitize user-supplied input. A remote attacker can leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site and to view arbitrary local files and directories within the context of the webserver. This may let the attacker steal cookie-based authentication credentials and gain access to sensitive information, which may aid in launching further attacks. Versions prior to Barco ClickShare 01.09.03, 01.06.02 and 01.03.02 are vulnerable. Barco ClickShare CSC-1 etc. are wireless presentation systems of Belgium Barco (Barco). A remote attacker can exploit this vulnerability to read the /etc/shadow file.
CVE-2016-3152 - /etc/shadow file disclosure in the CSC-1 firmware update Affected versions: all versions prior to v01.09.03 (CSC-1) It is possible to download and extract the firmware image of the CSC-1 and obtain the root password.
The vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance.
References: http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020&rev=001002000009 http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037&rev=001001000113 https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070&rev=001001000008
--
Regards,
Vincent Ruijter Ethical Hacker Chief Information Security Office KPN B.V
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201701-0403",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare cse-200",
"scope": "lte",
"trust": 1.0,
"vendor": "barco",
"version": "01.03.01.05"
},
{
"model": "clickshare csm-1",
"scope": "lte",
"trust": 1.0,
"vendor": "barco",
"version": "01.06.01.04"
},
{
"model": "clickshare csc-1",
"scope": "lte",
"trust": 1.0,
"vendor": "barco",
"version": "01.09.02.03"
},
{
"model": "clickshare csc-1",
"scope": null,
"trust": 0.8,
"vendor": "barco",
"version": null
},
{
"model": "clickshare csc-1",
"scope": "lt",
"trust": 0.8,
"vendor": "barco",
"version": "01.09.03"
},
{
"model": "clickshare cse-200",
"scope": null,
"trust": 0.8,
"vendor": "barco",
"version": null
},
{
"model": "clickshare cse-200",
"scope": "lt",
"trust": 0.8,
"vendor": "barco",
"version": "01.03.02"
},
{
"model": "clickshare csm-1",
"scope": null,
"trust": 0.8,
"vendor": "barco",
"version": null
},
{
"model": "clickshare csm-1",
"scope": "lt",
"trust": 0.8,
"vendor": "barco",
"version": "01.06.02"
},
{
"model": "clickshare csm-1",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "01.06.01.04"
},
{
"model": "clickshare csc-1",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "01.09.02.03"
},
{
"model": "clickshare cse-200",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "01.03.01.05"
},
{
"model": "clickshare",
"scope": "eq",
"trust": 0.3,
"vendor": "barco",
"version": "1.9.2"
},
{
"model": "clickshare",
"scope": "eq",
"trust": 0.3,
"vendor": "barco",
"version": "1.6.1"
},
{
"model": "clickshare",
"scope": "eq",
"trust": 0.3,
"vendor": "barco",
"version": "1.3.1"
},
{
"model": "clickshare",
"scope": "ne",
"trust": 0.3,
"vendor": "barco",
"version": "1.9.3"
},
{
"model": "clickshare",
"scope": "ne",
"trust": 0.3,
"vendor": "barco",
"version": "1.6.2"
},
{
"model": "clickshare",
"scope": "ne",
"trust": 0.3,
"vendor": "barco",
"version": "1.3.2"
}
],
"sources": [
{
"db": "BID",
"id": "94330"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006881"
},
{
"db": "NVD",
"id": "CVE-2016-3151"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-539"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_csc-1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "01.09.02.03",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_csc-1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_csm-1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "01.06.01.04",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_csm-1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "01.03.01.05",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2016-3151"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vincent Ruijter",
"sources": [
{
"db": "BID",
"id": "94330"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-539"
}
],
"trust": 1.0
},
"cve": "CVE-2016-3151",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": true,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2016-3151",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-91970",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2016-3151",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2016-3151",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201611-539",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-91970",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91970"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006881"
},
{
"db": "NVD",
"id": "CVE-2016-3151"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-539"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Directory traversal vulnerability in the wallpaper parsing functionality in Barco ClickShare CSC-1 devices with firmware before 01.09.03, CSM-1 devices with firmware before 01.06.02, and CSE-200 devices with firmware before 01.03.02 allows remote attackers to read /etc/shadow via unspecified vectors. Barco ClickShare is prone to a cross-site scripting vulnerability and a directory-traversal vulnerability because it fails to sufficiently sanitize user-supplied input. \nA remote attacker can leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site and to view arbitrary local files and directories within the context of the webserver. This may let the attacker steal cookie-based authentication credentials and gain access to sensitive information, which may aid in launching further attacks. \nVersions prior to Barco ClickShare 01.09.03, 01.06.02 and 01.03.02 are vulnerable. Barco ClickShare CSC-1 etc. are wireless presentation systems of Belgium Barco (Barco). A remote attacker can exploit this vulnerability to read the /etc/shadow file. \n\nCVE-2016-3152 - /etc/shadow file disclosure in the CSC-1 firmware update\nAffected versions: all versions prior to v01.09.03 (CSC-1)\nIt is possible to download and extract the firmware image of the CSC-1 and obtain the root password. \n\nThe vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance. \n\nReferences:\nhttp://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020\u0026rev=001002000009\nhttp://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037\u0026rev=001001000113\nhttps://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070\u0026rev=001001000008\n\n--\n\nRegards,\n\nVincent Ruijter\nEthical Hacker\nChief Information Security Office\nKPN B.V",
"sources": [
{
"db": "NVD",
"id": "CVE-2016-3151"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006881"
},
{
"db": "BID",
"id": "94330"
},
{
"db": "VULHUB",
"id": "VHN-91970"
},
{
"db": "PACKETSTORM",
"id": "139713"
}
],
"trust": 2.07
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2016-3151",
"trust": 2.9
},
{
"db": "PACKETSTORM",
"id": "139713",
"trust": 2.6
},
{
"db": "BID",
"id": "94330",
"trust": 2.0
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006881",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201611-539",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-91970",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91970"
},
{
"db": "BID",
"id": "94330"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006881"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "NVD",
"id": "CVE-2016-3151"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-539"
}
]
},
"id": "VAR-201701-0403",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-91970"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T12:29:52.339000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Update your ClickShare firmware",
"trust": 0.8,
"url": "https://www.barco.com/en/page/update-your-clickshare-firmware"
},
{
"title": "Barco ClickShare Repair measures for path traversal vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=65874"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-006881"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-539"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-22",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91970"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006881"
},
{
"db": "NVD",
"id": "CVE-2016-3151"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "http://packetstormsecurity.com/files/139713/barco-clickshare-xss-remote-code-execution-path-traversal.html"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/94330"
},
{
"trust": 1.1,
"url": "http://www.securityfocus.com/archive/1/539754/100/0/threaded"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-3151"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-3151"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/archive/1/archive/1/539754/100/0/threaded"
},
{
"trust": 0.3,
"url": "https://www.barco.com/en/clickshare"
},
{
"trust": 0.3,
"url": "http://seclists.org/bugtraq/2016/nov/49"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3149"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3151"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3152"
},
{
"trust": 0.1,
"url": "http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050037\u0026rev=001001000113"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3150"
},
{
"trust": 0.1,
"url": "http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=r33050020\u0026rev=001002000009"
},
{
"trust": 0.1,
"url": "https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050070\u0026rev=001001000008"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91970"
},
{
"db": "BID",
"id": "94330"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006881"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "NVD",
"id": "CVE-2016-3151"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-539"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-91970"
},
{
"db": "BID",
"id": "94330"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006881"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "NVD",
"id": "CVE-2016-3151"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-539"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-01-12T00:00:00",
"db": "VULHUB",
"id": "VHN-91970"
},
{
"date": "2016-11-14T00:00:00",
"db": "BID",
"id": "94330"
},
{
"date": "2017-01-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-006881"
},
{
"date": "2016-11-14T17:07:07",
"db": "PACKETSTORM",
"id": "139713"
},
{
"date": "2017-01-12T23:59:00.353000",
"db": "NVD",
"id": "CVE-2016-3151"
},
{
"date": "2016-11-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201611-539"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-91970"
},
{
"date": "2016-11-24T01:10:00",
"db": "BID",
"id": "94330"
},
{
"date": "2017-01-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-006881"
},
{
"date": "2018-10-09T19:59:47.473000",
"db": "NVD",
"id": "CVE-2016-3151"
},
{
"date": "2017-01-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201611-539"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-539"
}
],
"trust": 0.7
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Barco ClickShare Directory traversal vulnerability in wallpaper parsing function of device product firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-006881"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "path traversal",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201611-539"
}
],
"trust": 0.6
}
}
VAR-201701-0404
Vulnerability from variot - Updated: 2023-12-18 12:29Barco ClickShare CSC-1 devices with firmware before 01.09.03 allow remote attackers to obtain the root password by downloading and extracting the firmware image. Barco ClickShare is prone to a vulnerability that lets attacker access arbitrary files because it fails to adequately validate user-supplied input. An attacker can exploit this vulnerability to view arbitrary files within the context of the affected application. Versions prior to Barco ClickShare 01.09.03 are vulnerable. Barco ClickShare CSC-1 is a wireless presentation system from Barco, Belgium. Base Unit is one of the basic integration kits. A remote code execution vulnerability exists within the Barco ClickShare base unit software, that could lead to full compromise of the appliance.
CVE-2016-3150 - Cross-site Scripting in Barco ClickShare CSC-1, CSM-1 and CSE-200 Affected versions: all versions prior to v01.09.03 (CSC-1), v01.06.02 (CSM-1) and v01.03.02 (CSE-200) A Cross-Site Scripting vulnerability exists within Barco ClickShare's CSC-1 base unit's wallpaper.php due to invalid input and output sanitisation. A Path Traversal vulnerability exists within Barco ClickShare's wallpaper parsing functionality, which leads to disclosure of the /etc/shadow file on the file system.
The vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance.
References: http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020&rev=001002000009 http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037&rev=001001000113 https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070&rev=001001000008
--
Regards,
Vincent Ruijter Ethical Hacker Chief Information Security Office KPN B.V
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201701-0404",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare csc-1",
"scope": "lte",
"trust": 1.0,
"vendor": "barco",
"version": "01.09.02.03"
},
{
"model": "clickshare csc-1",
"scope": null,
"trust": 0.8,
"vendor": "barco",
"version": null
},
{
"model": "clickshare csc-1",
"scope": "lt",
"trust": 0.8,
"vendor": "barco",
"version": "01.09.03"
},
{
"model": "clickshare csc-1",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "01.09.02.03"
},
{
"model": "clickshare",
"scope": "eq",
"trust": 0.3,
"vendor": "barco",
"version": "1.9.2"
},
{
"model": "clickshare",
"scope": "ne",
"trust": 0.3,
"vendor": "barco",
"version": "1.9.3"
}
],
"sources": [
{
"db": "BID",
"id": "94326"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006882"
},
{
"db": "NVD",
"id": "CVE-2016-3152"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-542"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_csc-1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "01.09.02.03",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_csc-1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2016-3152"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vincent Ruijter",
"sources": [
{
"db": "BID",
"id": "94326"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-542"
}
],
"trust": 1.0
},
"cve": "CVE-2016-3152",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2016-3152",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-91971",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2016-3152",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2016-3152",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-201611-542",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-91971",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91971"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006882"
},
{
"db": "NVD",
"id": "CVE-2016-3152"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-542"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare CSC-1 devices with firmware before 01.09.03 allow remote attackers to obtain the root password by downloading and extracting the firmware image. Barco ClickShare is prone to a vulnerability that lets attacker access arbitrary files because it fails to adequately validate user-supplied input. \nAn attacker can exploit this vulnerability to view arbitrary files within the context of the affected application. \nVersions prior to Barco ClickShare 01.09.03 are vulnerable. Barco ClickShare CSC-1 is a wireless presentation system from Barco, Belgium. Base Unit is one of the basic integration kits. \nA remote code execution vulnerability exists within the Barco ClickShare base unit software, that could lead to full compromise of the appliance. \n\nCVE-2016-3150 - Cross-site Scripting in Barco ClickShare CSC-1, CSM-1 and CSE-200\nAffected versions: all versions prior to v01.09.03 (CSC-1), v01.06.02 (CSM-1) and v01.03.02 (CSE-200)\nA Cross-Site Scripting vulnerability exists within Barco ClickShare\u0027s CSC-1 base unit\u0027s wallpaper.php due to invalid input and output sanitisation. \nA Path Traversal vulnerability exists within Barco ClickShare\u0027s wallpaper parsing functionality, which leads to disclosure of the /etc/shadow file on the file system. \n\nThe vendor has acknowledged and patched the aforementioned issues. It is recommended to download and apply the most recent firmware update for your appliance. \n\nReferences:\nhttp://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=R33050020\u0026rev=001002000009\nhttp://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050037\u0026rev=001001000113\nhttps://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=R33050070\u0026rev=001001000008\n\n--\n\nRegards,\n\nVincent Ruijter\nEthical Hacker\nChief Information Security Office\nKPN B.V",
"sources": [
{
"db": "NVD",
"id": "CVE-2016-3152"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006882"
},
{
"db": "BID",
"id": "94326"
},
{
"db": "VULHUB",
"id": "VHN-91971"
},
{
"db": "PACKETSTORM",
"id": "139713"
}
],
"trust": 2.07
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2016-3152",
"trust": 2.9
},
{
"db": "PACKETSTORM",
"id": "139713",
"trust": 2.6
},
{
"db": "BID",
"id": "94326",
"trust": 2.0
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006882",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201611-542",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-91971",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91971"
},
{
"db": "BID",
"id": "94326"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006882"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "NVD",
"id": "CVE-2016-3152"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-542"
}
]
},
"id": "VAR-201701-0404",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-91971"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T12:29:52.306000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Update your ClickShare firmware",
"trust": 0.8,
"url": "https://www.barco.com/en/page/update-your-clickshare-firmware"
},
{
"title": "Barco ClickShare Repair measures for information disclosure vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=65877"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-006882"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-542"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91971"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006882"
},
{
"db": "NVD",
"id": "CVE-2016-3152"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "http://packetstormsecurity.com/files/139713/barco-clickshare-xss-remote-code-execution-path-traversal.html"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/94326"
},
{
"trust": 1.1,
"url": "http://www.securityfocus.com/archive/1/539754/100/0/threaded"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-3152"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-3152"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/archive/1/archive/1/539754/100/0/threaded"
},
{
"trust": 0.3,
"url": "https://www.barco.com/en/clickshare"
},
{
"trust": 0.3,
"url": "http://seclists.org/bugtraq/2016/nov/49"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3149"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3151"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3152"
},
{
"trust": 0.1,
"url": "http://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050037\u0026rev=001001000113"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2016-3150"
},
{
"trust": 0.1,
"url": "http://www.barco.com/en/mybarco/mysupport/documentation/software/software-detail?nr=r33050020\u0026rev=001002000009"
},
{
"trust": 0.1,
"url": "https://www.barco.com/en/mybarco/mysupport/productsupport/software/software-detail?nr=r33050070\u0026rev=001001000008"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-91971"
},
{
"db": "BID",
"id": "94326"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006882"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "NVD",
"id": "CVE-2016-3152"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-542"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-91971"
},
{
"db": "BID",
"id": "94326"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-006882"
},
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "NVD",
"id": "CVE-2016-3152"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-542"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-01-12T00:00:00",
"db": "VULHUB",
"id": "VHN-91971"
},
{
"date": "2016-11-14T00:00:00",
"db": "BID",
"id": "94326"
},
{
"date": "2017-01-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-006882"
},
{
"date": "2016-11-14T17:07:07",
"db": "PACKETSTORM",
"id": "139713"
},
{
"date": "2017-01-12T23:59:00.387000",
"db": "NVD",
"id": "CVE-2016-3152"
},
{
"date": "2016-11-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201611-542"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-91971"
},
{
"date": "2016-11-24T00:10:00",
"db": "BID",
"id": "94326"
},
{
"date": "2017-01-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-006882"
},
{
"date": "2018-10-09T19:59:47.817000",
"db": "NVD",
"id": "CVE-2016-3152"
},
{
"date": "2017-01-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201611-542"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "PACKETSTORM",
"id": "139713"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-542"
}
],
"trust": 0.7
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare CSC-1 In the device firmware root Password acquisition vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-006882"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201611-542"
}
],
"trust": 0.6
}
}
VAR-201912-0678
Vulnerability from variot - Updated: 2023-12-18 12:17On Barco ClickShare Button R9861500D01 devices (before firmware version 1.9.0) JTAG access is disabled after ROM code execution. This means that JTAG access is possible when the system is running code from ROM before handing control over to embedded firmware. Barco ClickShare Button R9861500D01 The device contains an input validation vulnerability.Information may be obtained
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201912-0678",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare cs-100",
"scope": "lt",
"trust": 1.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200",
"scope": "lt",
"trust": 1.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-800",
"scope": "lt",
"trust": 1.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200\\+",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200+",
"scope": "lt",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare button r9861500d01",
"scope": "lt",
"trust": 0.6,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.8.2.2"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.6.1.2"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.7.0.22"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.5.0.12"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.5.2.3"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": null
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.6.4.4"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.5.1.2"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.7.1.1"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.6,
"vendor": "barco",
"version": "1.6.2.7"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46445"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013804"
},
{
"db": "NVD",
"id": "CVE-2019-18827"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-728"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cs-100_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cs-100:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200\\+_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200\\+:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-800_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-800:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18827"
}
]
},
"cve": "CVE-2019-18827",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.3,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2019-18827",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.4,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-46445",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "High",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.9,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-18827",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-18827",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2019-46445",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201912-728",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46445"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013804"
},
{
"db": "NVD",
"id": "CVE-2019-18827"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-728"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "On Barco ClickShare Button R9861500D01 devices (before firmware version 1.9.0) JTAG access is disabled after ROM code execution. This means that JTAG access is possible when the system is running code from ROM before handing control over to embedded firmware. Barco ClickShare Button R9861500D01 The device contains an input validation vulnerability.Information may be obtained",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18827"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013804"
},
{
"db": "CNVD",
"id": "CNVD-2019-46445"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-18827",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013804",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2019-46445",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201912-728",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46445"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013804"
},
{
"db": "NVD",
"id": "CVE-2019-18827"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-728"
}
]
},
"id": "VAR-201912-0678",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46445"
}
],
"trust": 1.3368421000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46445"
}
]
},
"last_update_date": "2023-12-18T12:17:30.724000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Update your ClickShare device",
"trust": 0.8,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"title": "ClickShare CS-100 base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "ClickShare CSE-200 base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "ClickShare CSE-800 base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "ClickShare CSE-200+ base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "Patch for Barco ClickShare Button R9861500D01 has an unknown vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/194993"
},
{
"title": "Barco ClickShare Button R9861500D01 Enter the fix for the verification error vulnerability",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105993"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46445"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013804"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-728"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-285",
"trust": 1.0
},
{
"problemtype": "CWE-362",
"trust": 1.0
},
{
"problemtype": "CWE-20",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013804"
},
{
"db": "NVD",
"id": "CVE-2019-18827"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.2,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"trust": 2.2,
"url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-18827"
},
{
"trust": 1.6,
"url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18827"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46445"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013804"
},
{
"db": "NVD",
"id": "CVE-2019-18827"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-728"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-46445"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013804"
},
{
"db": "NVD",
"id": "CVE-2019-18827"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-728"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-46445"
},
{
"date": "2020-01-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013804"
},
{
"date": "2019-12-16T17:15:11.957000",
"db": "NVD",
"id": "CVE-2019-18827"
},
{
"date": "2019-12-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-728"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-46445"
},
{
"date": "2020-01-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013804"
},
{
"date": "2021-07-21T11:39:23.747000",
"db": "NVD",
"id": "CVE-2019-18827"
},
{
"date": "2019-12-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-728"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-728"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 Vulnerability related to input validation on devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013804"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "input validation error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-728"
}
],
"trust": 0.6
}
}
VAR-202011-0849
Vulnerability from variot - Updated: 2023-12-18 12:16Barco wePresent WiPG-1600W devices use Hard-coded Credentials (issue 2 of 2). Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W device has a hardcoded root password hash included in the firmware image. Exploiting CVE-2020-28329, CVE-2020-28330 and CVE-2020-28331 could potentially be used in a simple and automated exploit chain to go from unauthenticated remote attacker to root shell. Barco wePresent WiPG-1600W A device contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Barco wePresent WiPG-1600W is a management device used in conference environments from Barco in Belgium
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202011-0849",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wepresent wipg-1600w",
"scope": "eq",
"trust": 1.6,
"vendor": "barco",
"version": "2.5.1.8"
},
{
"model": "wepresent wipg-1600w",
"scope": "eq",
"trust": 1.6,
"vendor": "barco",
"version": "2.5.0.25"
},
{
"model": "wepresent wipg-1600w",
"scope": "eq",
"trust": 1.6,
"vendor": "barco",
"version": "2.5.0.24"
},
{
"model": "wepresent wipg-1600w",
"scope": "eq",
"trust": 1.6,
"vendor": "barco",
"version": "2.4.1.19"
},
{
"model": "wepresent wipg-1600w",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "wepresent wipg-1600w firmware 2.5.0.25"
},
{
"model": "wepresent wipg-1600w",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "wepresent wipg-1600w firmware 2.4.1.19"
},
{
"model": "wepresent wipg-1600w",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "wepresent wipg-1600w firmware 2.5.0.24"
},
{
"model": "wepresent wipg-1600w",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": null
},
{
"model": "wepresent wipg-1600w",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "wepresent wipg-1600w firmware 2.5.1.8"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-67561"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-013882"
},
{
"db": "NVD",
"id": "CVE-2020-28334"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:2.4.1.19:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:2.5.0.24:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:2.5.0.25:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:2.5.1.8:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:wepresent_wipg-1600w:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-28334"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Jim Becher",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202011-1775"
}
],
"trust": 0.6
},
"cve": "CVE-2020-28334",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2020-28334",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-67561",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2020-28334",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-28334",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2020-67561",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202011-1775",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-67561"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-013882"
},
{
"db": "NVD",
"id": "CVE-2020-28334"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1775"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco wePresent WiPG-1600W devices use Hard-coded Credentials (issue 2 of 2). Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W device has a hardcoded root password hash included in the firmware image. Exploiting CVE-2020-28329, CVE-2020-28330 and CVE-2020-28331 could potentially be used in a simple and automated exploit chain to go from unauthenticated remote attacker to root shell. Barco wePresent WiPG-1600W A device contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Barco wePresent WiPG-1600W is a management device used in conference environments from Barco in Belgium",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-28334"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-013882"
},
{
"db": "CNVD",
"id": "CNVD-2020-67561"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "PACKETSTORM",
"id": "160163",
"trust": 3.0
},
{
"db": "NVD",
"id": "CVE-2020-28334",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2020-013882",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-67561",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1775",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-67561"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-013882"
},
{
"db": "NVD",
"id": "CVE-2020-28334"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1775"
}
]
},
"id": "VAR-202011-0849",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-67561"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-67561"
}
]
},
"last_update_date": "2023-12-18T12:16:47.061000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "wePresent\u00a0WiPG-1600W",
"trust": 0.8,
"url": "https://www.barco.com/en/product/wepresent-wipg-1600w"
},
{
"title": "Patch for Barco wePresent WiPG-1600W hardcoded root password vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/241405"
},
{
"title": "Barco wePresent WiPG-1600W Repair measures for trust management problem vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=135798"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-67561"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-013882"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1775"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.0
},
{
"problemtype": "Using hardcoded credentials (CWE-798) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-013882"
},
{
"db": "NVD",
"id": "CVE-2020-28334"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.6,
"url": "http://packetstormsecurity.com/files/160163/barco-wepresent-global-hardcoded-root-ssh-password.html"
},
{
"trust": 1.6,
"url": "https://korelogic.com/resources/advisories/kl-001-2020-008.txt"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-28334"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-67561"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-013882"
},
{
"db": "NVD",
"id": "CVE-2020-28334"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1775"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-67561"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-013882"
},
{
"db": "NVD",
"id": "CVE-2020-28334"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1775"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-11-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-67561"
},
{
"date": "2021-07-14T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-013882"
},
{
"date": "2020-11-24T19:15:10.867000",
"db": "NVD",
"id": "CVE-2020-28334"
},
{
"date": "2020-11-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202011-1775"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-11-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-67561"
},
{
"date": "2021-07-14T08:23:00",
"db": "JVNDB",
"id": "JVNDB-2020-013882"
},
{
"date": "2020-12-03T17:39:44.927000",
"db": "NVD",
"id": "CVE-2020-28334"
},
{
"date": "2020-12-04T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202011-1775"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202011-1775"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco\u00a0wePresent\u00a0WiPG-1600W\u00a0 Vulnerability in using hard-coded credentials on devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-013882"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202011-1775"
}
],
"trust": 0.6
}
}
VAR-201710-0927
Vulnerability from variot - Updated: 2023-12-18 12:03An issue was discovered in Barco ClickShare CSM-1 firmware before v1.7.0.3 and CSC-1 firmware before v1.10.0.10. An authenticated user can manage the wallpaper collection in the webUI to be shown as background on the ClickShare product. By uploading a wallpaper with a specially crafted name, an HTML injection can be triggered as special characters are not neutralized before output. Barco ClickShare CSM-1 and CSC-1 The firmware contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. BarcoClickShareCSM-1 and ClickShareCSC-1 are both host devices for Barco's wireless presentation system. BarcoClickShareCSM-1 with firmware prior to 1.7.0.3 and BarcoClickShareCSC-1 with firmware prior to 1.10.0.10 have security vulnerabilities. There are currently no detailed details of the vulnerability provided
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201710-0927",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare csc-1",
"scope": "lt",
"trust": 1.6,
"vendor": "barco",
"version": "1.10.0.10"
},
{
"model": "clickshare csm-1",
"scope": "lt",
"trust": 1.6,
"vendor": "barco",
"version": "1.7.0.3"
},
{
"model": "clickshare csc-1",
"scope": "lt",
"trust": 0.8,
"vendor": "barco",
"version": "v1.10.0.10"
},
{
"model": "clickshare csm-1",
"scope": "lt",
"trust": 0.8,
"vendor": "barco",
"version": "v1.7.0.3"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-36376"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009767"
},
{
"db": "NVD",
"id": "CVE-2017-12460"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_csm-1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.7.0.3",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_csm-1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_csc-1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.10.0.10",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_csc-1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-12460"
}
]
},
"cve": "CVE-2017-12460",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "LOW",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 3.5,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2017-12460",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Low",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.8,
"id": "CNVD-2017-36376",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.4,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2017-12460",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "Low",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-12460",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2017-36376",
"trust": 0.6,
"value": "LOW"
},
{
"author": "CNNVD",
"id": "CNNVD-201710-1240",
"trust": 0.6,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-36376"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009767"
},
{
"db": "NVD",
"id": "CVE-2017-12460"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-1240"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered in Barco ClickShare CSM-1 firmware before v1.7.0.3 and CSC-1 firmware before v1.10.0.10. An authenticated user can manage the wallpaper collection in the webUI to be shown as background on the ClickShare product. By uploading a wallpaper with a specially crafted name, an HTML injection can be triggered as special characters are not neutralized before output. Barco ClickShare CSM-1 and CSC-1 The firmware contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. BarcoClickShareCSM-1 and ClickShareCSC-1 are both host devices for Barco\u0027s wireless presentation system. BarcoClickShareCSM-1 with firmware prior to 1.7.0.3 and BarcoClickShareCSC-1 with firmware prior to 1.10.0.10 have security vulnerabilities. There are currently no detailed details of the vulnerability provided",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-12460"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009767"
},
{
"db": "CNVD",
"id": "CNVD-2017-36376"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-12460",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009767",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2017-36376",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201710-1240",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-36376"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009767"
},
{
"db": "NVD",
"id": "CVE-2017-12460"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-1240"
}
]
},
"id": "VAR-201710-0927",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-36376"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-36376"
}
]
},
"last_update_date": "2023-12-18T12:03:12.023000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Is ClickShare protected against HTML injection? [KB5169]",
"trust": 0.8,
"url": "https://www.barco.com/en/support/knowledge-base/kb5169"
},
{
"title": "ClickShare CSC-1 Base Unit Firmware v1.10.0.10",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050020"
},
{
"title": "ClickShare CSM-1 Base Unit Firmware v1.7.0.3",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050037"
},
{
"title": "BarcoClickShareCSM-1 and ClickShareCSC-1 have unexplained patches",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/107881"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-36376"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009767"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-009767"
},
{
"db": "NVD",
"id": "CVE-2017-12460"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://www.barco.com/en/support/software/r33050037"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/support/software/r33050020"
},
{
"trust": 1.0,
"url": "https://www.barco.com/en/support/knowledge-base/kb5169"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-12460"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-12460"
},
{
"trust": 0.6,
"url": "http://www.barco.com.cn/en/support/software/r33050020"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-36376"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009767"
},
{
"db": "NVD",
"id": "CVE-2017-12460"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-1240"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2017-36376"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009767"
},
{
"db": "NVD",
"id": "CVE-2017-12460"
},
{
"db": "CNNVD",
"id": "CNNVD-201710-1240"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-12-06T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-36376"
},
{
"date": "2017-11-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-009767"
},
{
"date": "2017-10-30T14:29:00.797000",
"db": "NVD",
"id": "CVE-2017-12460"
},
{
"date": "2017-10-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201710-1240"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-12-06T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-36376"
},
{
"date": "2017-11-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-009767"
},
{
"date": "2017-11-18T16:21:33.540000",
"db": "NVD",
"id": "CVE-2017-12460"
},
{
"date": "2017-11-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201710-1240"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201710-1240"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare CSM-1 and CSC-1 Firmware cross-site scripting vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-009767"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201710-1240"
}
],
"trust": 0.6
}
}
VAR-201904-0320
Vulnerability from variot - Updated: 2023-12-18 12:00The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root. Crestron AM-100 There is a command injection vulnerability in products such as firmware.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. A command injection vulnerability exists in several routers. This vulnerability stems from the fact that the network system or product does not correctly filter special elements in the process of constructing executable commands from external input data
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201904-0320",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wepresent wipg-1000p",
"scope": "eq",
"trust": 1.8,
"vendor": "barco",
"version": "2.3.0.10"
},
{
"model": "wepresent wipg-1600w",
"scope": "lt",
"trust": 1.8,
"vendor": "barco",
"version": "2.4.1.19"
},
{
"model": "sharelink 200",
"scope": "eq",
"trust": 1.8,
"vendor": "extron",
"version": "2.0.3.4"
},
{
"model": "sharelink 250",
"scope": "eq",
"trust": 1.8,
"vendor": "extron",
"version": "2.0.3.4"
},
{
"model": "liteshow3",
"scope": "eq",
"trust": 1.8,
"vendor": "infocus",
"version": "1.0.16"
},
{
"model": "liteshow4",
"scope": "eq",
"trust": 1.8,
"vendor": "infocus",
"version": "2.0.0.7"
},
{
"model": "wps-pro",
"scope": "eq",
"trust": 1.8,
"vendor": "optoma",
"version": "1.0.0.5"
},
{
"model": "pn-l703wa",
"scope": "eq",
"trust": 1.8,
"vendor": "sharp",
"version": "1.4.2.3"
},
{
"model": "am-100",
"scope": "eq",
"trust": 1.0,
"vendor": "crestron",
"version": "1.6.0.2"
},
{
"model": "am-101",
"scope": "eq",
"trust": 1.0,
"vendor": "crestron",
"version": "2.7.0.2"
},
{
"model": "hd wireless presentation system",
"scope": "eq",
"trust": 1.0,
"vendor": "blackbox",
"version": "1.0.0.5"
},
{
"model": "wips710",
"scope": "eq",
"trust": 1.0,
"vendor": "teqavit",
"version": "1.1.0.7"
},
{
"model": "hd wireless presentation system",
"scope": "eq",
"trust": 0.8,
"vendor": "black box network services",
"version": "1.0.0.5"
},
{
"model": "airmedia am-100",
"scope": "eq",
"trust": 0.8,
"vendor": "crestron",
"version": "1.6.0.2"
},
{
"model": "airmedia am-101",
"scope": "eq",
"trust": 0.8,
"vendor": "crestron",
"version": "2.7.0.1"
},
{
"model": "wips710",
"scope": "eq",
"trust": 0.8,
"vendor": "teq avit",
"version": "1.1.0.7"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004073"
},
{
"db": "NVD",
"id": "CVE-2019-3929"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:crestron:am-100_firmware:1.6.0.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:crestron:am-100:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:crestron:am-101_firmware:2.7.0.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:crestron:am-101:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1000p_firmware:2.3.0.10:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:wepresent_wipg-1000p:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.4.1.19",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:wepresent_wipg-1600w:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:extron:sharelink_200_firmware:2.0.3.4:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:extron:sharelink_200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:extron:sharelink_250_firmware:2.0.3.4:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:extron:sharelink_250:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:teqavit:wips710_firmware:1.1.0.7:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:teqavit:wips710:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:sharp:pn-l703wa_firmware:1.4.2.3:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:sharp:pn-l703wa:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:optoma:wps-pro_firmware:1.0.0.5:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:optoma:wps-pro:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:blackbox:hd_wireless_presentation_system_firmware:1.0.0.5:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:blackbox:hd_wireless_presentation_system:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:infocus:liteshow3_firmware:1.0.16:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:infocus:liteshow3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:infocus:liteshow4_firmware:2.0.0.7:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:infocus:liteshow4:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-3929"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Jacob Baines",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201904-1386"
}
],
"trust": 0.6
},
"cve": "CVE-2019-3929",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2019-3929",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-155364",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-3929",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-3929",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-201904-1386",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-155364",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2019-3929",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-155364"
},
{
"db": "VULMON",
"id": "CVE-2019-3929"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004073"
},
{
"db": "NVD",
"id": "CVE-2019-3929"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-1386"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root. Crestron AM-100 There is a command injection vulnerability in products such as firmware.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. A command injection vulnerability exists in several routers. This vulnerability stems from the fact that the network system or product does not correctly filter special elements in the process of constructing executable commands from external input data",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-3929"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004073"
},
{
"db": "VULHUB",
"id": "VHN-155364"
},
{
"db": "VULMON",
"id": "CVE-2019-3929"
}
],
"trust": 1.8
},
"exploit_availability": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"reference": "https://www.scap.org.cn/vuln/vhn-155364",
"trust": 0.1,
"type": "unknown"
},
{
"reference": "https://vulmon.com/exploitdetails?qidtp=exploitdb\u0026qid=46786",
"trust": 0.1,
"type": "exploit"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-155364"
},
{
"db": "VULMON",
"id": "CVE-2019-3929"
}
]
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-3929",
"trust": 2.6
},
{
"db": "TENABLE",
"id": "TRA-2019-20",
"trust": 2.6
},
{
"db": "EXPLOIT-DB",
"id": "46786",
"trust": 1.8
},
{
"db": "PACKETSTORM",
"id": "155948",
"trust": 1.8
},
{
"db": "PACKETSTORM",
"id": "152715",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004073",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201904-1386",
"trust": 0.7
},
{
"db": "EXPLOIT-DB",
"id": "47924",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-155364",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2019-3929",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-155364"
},
{
"db": "VULMON",
"id": "CVE-2019-3929"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004073"
},
{
"db": "NVD",
"id": "CVE-2019-3929"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-1386"
}
]
},
"id": "VAR-201904-0320",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-155364"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T12:00:23.448000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "wePresent WiPG-1000",
"trust": 0.8,
"url": "https://www.barco.com/en/product/wepresent-wipg-1000"
},
{
"title": "wePresent WiPG-1600W",
"trust": 0.8,
"url": "https://www.barco.com/en/product/wepresent-wipg-1600w"
},
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.blackbox.com/en-us"
},
{
"title": "AM-100",
"trust": 0.8,
"url": "https://www.crestron.com/en-us/products/workspace-solutions/wireless-presentation-solutions/airmedia-presentation-gateways/am-100"
},
{
"title": "AM-101",
"trust": 0.8,
"url": "https://www.crestron.com/en-us/products/workspace-solutions/wireless-presentation-solutions/airmedia-presentation-gateways/am-101"
},
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.extron.com/"
},
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.infocus.com/"
},
{
"title": "WPS Pro",
"trust": 0.8,
"url": "https://www.optoma.com/us/product/wps-pro/"
},
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.teq-avit.com/"
},
{
"title": "PN-L703WA",
"trust": 0.8,
"url": "https://jp.sharp/business/bigpad/lineup/pnl703wa/"
},
{
"title": "CVE-2019-3929",
"trust": 0.1,
"url": "https://github.com/xfox64x/cve-2019-3929 "
},
{
"title": "PoC-in-GitHub",
"trust": 0.1,
"url": "https://github.com/developer3000s/poc-in-github "
},
{
"title": "CVE-POC",
"trust": 0.1,
"url": "https://github.com/0xt11/cve-poc "
},
{
"title": "PoC-in-GitHub",
"trust": 0.1,
"url": "https://github.com/hectorgie/poc-in-github "
},
{
"title": "PoC-in-GitHub",
"trust": 0.1,
"url": "https://github.com/nomi-sec/poc-in-github "
},
{
"title": "Threatpost",
"trust": 0.1,
"url": "https://threatpost.com/bugs-wireless-presentation-systems/144318/"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-3929"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004073"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.1
},
{
"problemtype": "CWE-77",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-155364"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004073"
},
{
"db": "NVD",
"id": "CVE-2019-3929"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "http://packetstormsecurity.com/files/152715/barco-awind-oem-presentation-platform-unauthenticated-remote-command-injection.html"
},
{
"trust": 2.6,
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"trust": 1.8,
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"trust": 1.8,
"url": "http://packetstormsecurity.com/files/155948/barco-wepresent-file_transfer.cgi-command-injection.html"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-3929"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-3929"
},
{
"trust": 0.7,
"url": "https://www.exploit-db.com/exploits/46786"
},
{
"trust": 0.6,
"url": "https://www.exploit-db.com/exploits/47924"
},
{
"trust": 0.6,
"url": "https://packetstormsecurity.com/files/155948/barco-wepresent-file/transfer.cgi-command-injection.html"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"trust": 0.1,
"url": "https://github.com/xfox64x/cve-2019-3929"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-155364"
},
{
"db": "VULMON",
"id": "CVE-2019-3929"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004073"
},
{
"db": "NVD",
"id": "CVE-2019-3929"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-1386"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-155364"
},
{
"db": "VULMON",
"id": "CVE-2019-3929"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004073"
},
{
"db": "NVD",
"id": "CVE-2019-3929"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-1386"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-04-30T00:00:00",
"db": "VULHUB",
"id": "VHN-155364"
},
{
"date": "2019-04-30T00:00:00",
"db": "VULMON",
"id": "CVE-2019-3929"
},
{
"date": "2019-05-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004073"
},
{
"date": "2019-04-30T21:29:00.713000",
"db": "NVD",
"id": "CVE-2019-3929"
},
{
"date": "2019-04-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201904-1386"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-10-16T00:00:00",
"db": "VULHUB",
"id": "VHN-155364"
},
{
"date": "2020-10-16T00:00:00",
"db": "VULMON",
"id": "CVE-2019-3929"
},
{
"date": "2019-05-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004073"
},
{
"date": "2020-10-16T18:09:51.387000",
"db": "NVD",
"id": "CVE-2019-3929"
},
{
"date": "2020-10-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201904-1386"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201904-1386"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Crestron AM-100 Command injection vulnerability in products such as firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004073"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201904-1386"
}
],
"trust": 0.6
}
}
VAR-201904-0321
Vulnerability from variot - Updated: 2023-12-18 12:00The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so's PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint. Crestron AM-100 Firmware and other products have a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. A buffer error vulnerability exists in the 'PARSERtoCHAR' function of the libAwgCgi.so file in several routers. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201904-0321",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wepresent wipg-1000p",
"scope": "eq",
"trust": 1.8,
"vendor": "barco",
"version": "2.3.0.10"
},
{
"model": "wepresent wipg-1600w",
"scope": "lt",
"trust": 1.8,
"vendor": "barco",
"version": "2.4.1.19"
},
{
"model": "sharelink 200",
"scope": "eq",
"trust": 1.8,
"vendor": "extron",
"version": "2.0.3.4"
},
{
"model": "sharelink 250",
"scope": "eq",
"trust": 1.8,
"vendor": "extron",
"version": "2.0.3.4"
},
{
"model": "liteshow3",
"scope": "eq",
"trust": 1.8,
"vendor": "infocus",
"version": "1.0.16"
},
{
"model": "liteshow4",
"scope": "eq",
"trust": 1.8,
"vendor": "infocus",
"version": "2.0.0.7"
},
{
"model": "wps-pro",
"scope": "eq",
"trust": 1.8,
"vendor": "optoma",
"version": "1.0.0.5"
},
{
"model": "pn-l703wa",
"scope": "eq",
"trust": 1.8,
"vendor": "sharp",
"version": "1.4.2.3"
},
{
"model": "am-100",
"scope": "eq",
"trust": 1.0,
"vendor": "crestron",
"version": "1.6.0.2"
},
{
"model": "am-101",
"scope": "eq",
"trust": 1.0,
"vendor": "crestron",
"version": "2.7.0.2"
},
{
"model": "hd wireless presentation system",
"scope": "eq",
"trust": 1.0,
"vendor": "blackbox",
"version": "1.0.0.5"
},
{
"model": "wips710",
"scope": "eq",
"trust": 1.0,
"vendor": "teqavit",
"version": "1.1.0.7"
},
{
"model": "hd wireless presentation system",
"scope": "eq",
"trust": 0.8,
"vendor": "black box network services",
"version": "1.0.0.5"
},
{
"model": "airmedia am-100",
"scope": "eq",
"trust": 0.8,
"vendor": "crestron",
"version": "1.6.0.2"
},
{
"model": "airmedia am-101",
"scope": "eq",
"trust": 0.8,
"vendor": "crestron",
"version": "2.7.0.1"
},
{
"model": "wips710",
"scope": "eq",
"trust": 0.8,
"vendor": "teq avit",
"version": "1.1.0.7"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004039"
},
{
"db": "NVD",
"id": "CVE-2019-3930"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:crestron:am-100_firmware:1.6.0.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:crestron:am-100:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:crestron:am-101_firmware:2.7.0.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:crestron:am-101:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1000p_firmware:2.3.0.10:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:wepresent_wipg-1000p:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.4.1.19",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:wepresent_wipg-1600w:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:extron:sharelink_200_firmware:2.0.3.4:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:extron:sharelink_200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:extron:sharelink_250_firmware:2.0.3.4:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:extron:sharelink_250:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:teqavit:wips710_firmware:1.1.0.7:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:teqavit:wips710:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:sharp:pn-l703wa_firmware:1.4.2.3:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:sharp:pn-l703wa:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:optoma:wps-pro_firmware:1.0.0.5:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:optoma:wps-pro:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:blackbox:hd_wireless_presentation_system_firmware:1.0.0.5:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:blackbox:hd_wireless_presentation_system:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:infocus:liteshow3_firmware:1.0.16:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:infocus:liteshow3:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:infocus:liteshow4_firmware:2.0.0.7:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:infocus:liteshow4:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-3930"
}
]
},
"cve": "CVE-2019-3930",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2019-3930",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-155365",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-3930",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-3930",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-201904-1388",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-155365",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2019-3930",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-155365"
},
{
"db": "VULMON",
"id": "CVE-2019-3930"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004039"
},
{
"db": "NVD",
"id": "CVE-2019-3930"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-1388"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so\u0027s PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint. Crestron AM-100 Firmware and other products have a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. A buffer error vulnerability exists in the \u0027PARSERtoCHAR\u0027 function of the libAwgCgi.so file in several routers. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-3930"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004039"
},
{
"db": "VULHUB",
"id": "VHN-155365"
},
{
"db": "VULMON",
"id": "CVE-2019-3930"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-3930",
"trust": 2.6
},
{
"db": "TENABLE",
"id": "TRA-2019-20",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004039",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201904-1388",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-155365",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2019-3930",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-155365"
},
{
"db": "VULMON",
"id": "CVE-2019-3930"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004039"
},
{
"db": "NVD",
"id": "CVE-2019-3930"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-1388"
}
]
},
"id": "VAR-201904-0321",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-155365"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T12:00:23.341000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "wePresent WiPG-1000",
"trust": 0.8,
"url": "https://www.barco.com/en/product/wepresent-wipg-1000"
},
{
"title": "wePresent WiPG-1600W",
"trust": 0.8,
"url": "https://www.barco.com/en/product/wepresent-wipg-1600w"
},
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.blackbox.com/en-us"
},
{
"title": "AM-100",
"trust": 0.8,
"url": "https://www.crestron.com/en-us/products/workspace-solutions/wireless-presentation-solutions/airmedia-presentation-gateways/am-100"
},
{
"title": "AM-101",
"trust": 0.8,
"url": "https://www.crestron.com/en-us/products/workspace-solutions/wireless-presentation-solutions/airmedia-presentation-gateways/am-101"
},
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.extron.com/"
},
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.infocus.com/"
},
{
"title": "WPS Pro",
"trust": 0.8,
"url": "https://www.optoma.com/us/product/wps-pro/"
},
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.teq-avit.com/"
},
{
"title": "PN-L703WA",
"trust": 0.8,
"url": "https://jp.sharp/business/bigpad/lineup/pnl703wa/"
},
{
"title": "Threatpost",
"trust": 0.1,
"url": "https://threatpost.com/bugs-wireless-presentation-systems/144318/"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-3930"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004039"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.1
},
{
"problemtype": "CWE-119",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-155365"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004039"
},
{
"db": "NVD",
"id": "CVE-2019-3930"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-3930"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-3930"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://threatpost.com/bugs-wireless-presentation-systems/144318/"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-155365"
},
{
"db": "VULMON",
"id": "CVE-2019-3930"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004039"
},
{
"db": "NVD",
"id": "CVE-2019-3930"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-1388"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-155365"
},
{
"db": "VULMON",
"id": "CVE-2019-3930"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004039"
},
{
"db": "NVD",
"id": "CVE-2019-3930"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-1388"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-04-30T00:00:00",
"db": "VULHUB",
"id": "VHN-155365"
},
{
"date": "2019-04-30T00:00:00",
"db": "VULMON",
"id": "CVE-2019-3930"
},
{
"date": "2019-05-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004039"
},
{
"date": "2019-04-30T21:29:00.777000",
"db": "NVD",
"id": "CVE-2019-3930"
},
{
"date": "2019-04-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201904-1388"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-10-16T00:00:00",
"db": "VULHUB",
"id": "VHN-155365"
},
{
"date": "2020-10-16T00:00:00",
"db": "VULMON",
"id": "CVE-2019-3930"
},
{
"date": "2019-05-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004039"
},
{
"date": "2020-10-16T18:30:20.047000",
"db": "NVD",
"id": "CVE-2019-3930"
},
{
"date": "2020-10-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201904-1388"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201904-1388"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Crestron AM-100 Buffer error vulnerability in products such as firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004039"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201904-1388"
}
],
"trust": 0.6
}
}
VAR-201912-0679
Vulnerability from variot - Updated: 2023-12-18 11:02Barco ClickShare Button R9861500D01 devices before 1.9.0 have Insufficiently Protected Credentials. The root account (present for access via debug interfaces, which are by default not enabled on production devices) of the embedded Linux on the ClickShare Button is using a weak password. Barco ClickShare Button The device contains a vulnerability related to information disclosure from the cache.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The vulnerability originated from the program's insufficient protection of credentials, and an attacker could use this vulnerability to gain root user identity
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201912-0679",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clickshare cse-200",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200\\+",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-800",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cs-100",
"scope": "lt",
"trust": 1.0,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cs-100",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-200+",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare cse-800",
"scope": "eq",
"trust": 0.8,
"vendor": "barco",
"version": "1.9.0"
},
{
"model": "clickshare button r9861500d01",
"scope": "lt",
"trust": 0.6,
"vendor": "barco",
"version": "1.9.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46444"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013418"
},
{
"db": "NVD",
"id": "CVE-2019-18828"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cs-100_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cs-100:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-200\\+_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-200\\+:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:barco:clickshare_cse-800_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:barco:clickshare_cse-800:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18828"
}
]
},
"cve": "CVE-2019-18828",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Local",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 7.2,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2019-18828",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-46444",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Physical",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.8,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-18828",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-18828",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2019-46444",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201912-727",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46444"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013418"
},
{
"db": "NVD",
"id": "CVE-2019-18828"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-727"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button R9861500D01 devices before 1.9.0 have Insufficiently Protected Credentials. The root account (present for access via debug interfaces, which are by default not enabled on production devices) of the embedded Linux on the ClickShare Button is using a weak password. Barco ClickShare Button The device contains a vulnerability related to information disclosure from the cache.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The vulnerability originated from the program\u0027s insufficient protection of credentials, and an attacker could use this vulnerability to gain root user identity",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18828"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013418"
},
{
"db": "CNVD",
"id": "CNVD-2019-46444"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-18828",
"trust": 3.0
},
{
"db": "JVN",
"id": "JVNVU93632155",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013418",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2019-46444",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201912-727",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46444"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013418"
},
{
"db": "NVD",
"id": "CVE-2019-18828"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-727"
}
]
},
"id": "VAR-201912-0679",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46444"
}
],
"trust": 1.3368421000000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46444"
}
]
},
"last_update_date": "2023-12-18T11:02:43.021000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "ClickShare",
"trust": 0.8,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"title": "ClickShare CS-100 base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "ClickShare CSE-200 base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "ClickShare CSE-800 base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "ClickShare CSE-200+ base unit firmware v1.9.1.7",
"trust": 0.8,
"url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"title": "Patch for Barco ClickShare Button R9861500D01 Insufficient Credential Protection Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/194987"
},
{
"title": "Barco ClickShare Button R9861500D01 Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=105750"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46444"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013418"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-727"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-521",
"trust": 1.0
},
{
"problemtype": "CWE-522",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013418"
},
{
"db": "NVD",
"id": "CVE-2019-18828"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.2,
"url": "https://labs.f-secure.com/advisories/multiple-vulnerabilities-in-barco-clickshare/"
},
{
"trust": 2.2,
"url": "https://www.barco.com/en/support/software/r33050069?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-18828"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/clickshare/firmware-update"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/support/software/r33050070?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/support/software/r33050095?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 1.6,
"url": "https://www.barco.com/en/support/software/r33050125?majorversion=01\u0026minorversion=09\u0026patchversion=01\u0026buildversion=007"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18828"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu93632155/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-46444"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013418"
},
{
"db": "NVD",
"id": "CVE-2019-18828"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-727"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-46444"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013418"
},
{
"db": "NVD",
"id": "CVE-2019-18828"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-727"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-46444"
},
{
"date": "2019-12-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013418"
},
{
"date": "2019-12-16T17:15:12.017000",
"db": "NVD",
"id": "CVE-2019-18828"
},
{
"date": "2019-12-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-727"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-46444"
},
{
"date": "2019-12-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013418"
},
{
"date": "2020-08-24T17:37:01.140000",
"db": "NVD",
"id": "CVE-2019-18828"
},
{
"date": "2020-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-727"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Barco ClickShare Button Vulnerability related to information leak from cache in device",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013418"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-727"
}
],
"trust": 0.6
}
}
CVE-2022-26978 (GCVE-0-2022-26978)
Vulnerability from nvd – Published: 2022-06-01 11:35 – Updated: 2024-08-03 05:18- n/a
| URL | Tags |
|---|---|
| https://www.barco.com/en/support/transform-n-mana… | x_refsource_MISC |
| https://www.barco.com/en/support/knowledge-base/KB12686 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:18:39.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12686"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /checklogin.jsp endpoint. The os_username parameters is not correctly sanitized, leading to reflected XSS."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-01T11:35:22.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12686"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-26978",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /checklogin.jsp endpoint. The os_username parameters is not correctly sanitized, leading to reflected XSS."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.barco.com/en/support/transform-n-management-server",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"name": "https://www.barco.com/en/support/knowledge-base/KB12686",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/knowledge-base/KB12686"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-26978",
"datePublished": "2022-06-01T11:35:22.000Z",
"dateReserved": "2022-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-03T05:18:39.136Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26977 (GCVE-0-2022-26977)
Vulnerability from nvd – Published: 2022-06-01 11:35 – Updated: 2024-08-03 05:18- n/a
| URL | Tags |
|---|---|
| https://www.barco.com/en/support/transform-n-mana… | x_refsource_MISC |
| https://www.barco.com/en/support/knowledge-base/KB12683 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:18:39.263Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12683"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization of the upload mechanism is leads to stored XSS."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-01T11:35:16.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12683"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-26977",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization of the upload mechanism is leads to stored XSS."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.barco.com/en/support/transform-n-management-server",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"name": "https://www.barco.com/en/support/knowledge-base/KB12683",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/knowledge-base/KB12683"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-26977",
"datePublished": "2022-06-01T11:35:16.000Z",
"dateReserved": "2022-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-03T05:18:39.263Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26976 (GCVE-0-2022-26976)
Vulnerability from nvd – Published: 2022-06-01 11:35 – Updated: 2024-08-03 05:18- n/a
| URL | Tags |
|---|---|
| https://www.barco.com/en/support/transform-n-mana… | x_refsource_MISC |
| https://www.barco.com/en/support/knowledge-base/KB12682 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:18:39.221Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12682"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization in the upload mechanism is leads to reflected XSS."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-01T11:35:06.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12682"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-26976",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization in the upload mechanism is leads to reflected XSS."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.barco.com/en/support/transform-n-management-server",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"name": "https://www.barco.com/en/support/knowledge-base/KB12682",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/knowledge-base/KB12682"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-26976",
"datePublished": "2022-06-01T11:35:06.000Z",
"dateReserved": "2022-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-03T05:18:39.221Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26975 (GCVE-0-2022-26975)
Vulnerability from nvd – Published: 2022-06-01 11:34 – Updated: 2024-08-03 05:18- n/a
| URL | Tags |
|---|---|
| https://www.barco.com/en/support/transform-n-mana… | x_refsource_MISC |
| https://www.barco.com/en/support/knowledge-base/KB12677 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:18:39.305Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12677"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing log files without authentication."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-01T11:34:59.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12677"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-26975",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing log files without authentication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.barco.com/en/support/transform-n-management-server",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"name": "https://www.barco.com/en/support/knowledge-base/KB12677",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/knowledge-base/KB12677"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-26975",
"datePublished": "2022-06-01T11:34:59.000Z",
"dateReserved": "2022-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-03T05:18:39.305Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26974 (GCVE-0-2022-26974)
Vulnerability from nvd – Published: 2022-06-01 11:34 – Updated: 2024-08-03 05:18- n/a
| URL | Tags |
|---|---|
| https://www.barco.com/en/support/transform-n-mana… | x_refsource_MISC |
| https://www.barco.com/en/support/knowledge-base/KB12684 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:18:39.396Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12684"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a file upload mechanism. Lack of input sanitization in the upload mechanism leads to reflected XSS."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-01T11:34:54.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12684"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-26974",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a file upload mechanism. Lack of input sanitization in the upload mechanism leads to reflected XSS."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.barco.com/en/support/transform-n-management-server",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"name": "https://www.barco.com/en/support/knowledge-base/KB12684",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/knowledge-base/KB12684"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-26974",
"datePublished": "2022-06-01T11:34:54.000Z",
"dateReserved": "2022-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-03T05:18:39.396Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26973 (GCVE-0-2022-26973)
Vulnerability from nvd – Published: 2022-06-01 11:34 – Updated: 2024-08-03 05:18- n/a
| URL | Tags |
|---|---|
| https://www.barco.com/en/support/transform-n-mana… | x_refsource_MISC |
| https://www.barco.com/en/support/knowledge-base/KB12678 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:18:39.210Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12678"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. By tweaking the license file name, the returned error message exposes internal directory path details."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-01T11:34:48.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12678"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-26973",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. By tweaking the license file name, the returned error message exposes internal directory path details."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.barco.com/en/support/transform-n-management-server",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"name": "https://www.barco.com/en/support/knowledge-base/KB12678",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/knowledge-base/KB12678"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-26973",
"datePublished": "2022-06-01T11:34:48.000Z",
"dateReserved": "2022-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-03T05:18:39.210Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26972 (GCVE-0-2022-26972)
Vulnerability from nvd – Published: 2022-06-01 11:34 – Updated: 2024-08-03 05:18- n/a
| URL | Tags |
|---|---|
| https://www.barco.com/en/support/transform-n-mana… | x_refsource_MISC |
| https://www.barco.com/en/support/knowledge-base/KB12685 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:18:38.461Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12685"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /cgi-bin endpoint. The URL parameters are not correctly sanitized, leading to reflected XSS."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-01T11:34:42.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12685"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-26972",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /cgi-bin endpoint. The URL parameters are not correctly sanitized, leading to reflected XSS."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.barco.com/en/support/transform-n-management-server",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"name": "https://www.barco.com/en/support/knowledge-base/KB12685",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/knowledge-base/KB12685"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-26972",
"datePublished": "2022-06-01T11:34:42.000Z",
"dateReserved": "2022-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-03T05:18:38.461Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26971 (GCVE-0-2022-26971)
Vulnerability from nvd – Published: 2022-06-01 11:34 – Updated: 2024-08-03 05:18- n/a
| URL | Tags |
|---|---|
| https://www.barco.com/en/support/transform-n-mana… | x_refsource_MISC |
| https://www.barco.com/en/support/knowledge-base/KB12681 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:18:39.263Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12681"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. This upload can be executed without authentication."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-01T11:34:37.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12681"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-26971",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. This upload can be executed without authentication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.barco.com/en/support/transform-n-management-server",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"name": "https://www.barco.com/en/support/knowledge-base/KB12681",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/knowledge-base/KB12681"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-26971",
"datePublished": "2022-06-01T11:34:37.000Z",
"dateReserved": "2022-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-03T05:18:39.263Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26978 (GCVE-0-2022-26978)
Vulnerability from cvelistv5 – Published: 2022-06-01 11:35 – Updated: 2024-08-03 05:18- n/a
| URL | Tags |
|---|---|
| https://www.barco.com/en/support/transform-n-mana… | x_refsource_MISC |
| https://www.barco.com/en/support/knowledge-base/KB12686 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:18:39.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12686"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /checklogin.jsp endpoint. The os_username parameters is not correctly sanitized, leading to reflected XSS."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-01T11:35:22.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12686"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-26978",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a URL /checklogin.jsp endpoint. The os_username parameters is not correctly sanitized, leading to reflected XSS."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.barco.com/en/support/transform-n-management-server",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"name": "https://www.barco.com/en/support/knowledge-base/KB12686",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/knowledge-base/KB12686"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-26978",
"datePublished": "2022-06-01T11:35:22.000Z",
"dateReserved": "2022-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-03T05:18:39.136Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26977 (GCVE-0-2022-26977)
Vulnerability from cvelistv5 – Published: 2022-06-01 11:35 – Updated: 2024-08-03 05:18- n/a
| URL | Tags |
|---|---|
| https://www.barco.com/en/support/transform-n-mana… | x_refsource_MISC |
| https://www.barco.com/en/support/knowledge-base/KB12683 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:18:39.263Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12683"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization of the upload mechanism is leads to stored XSS."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-01T11:35:16.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12683"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-26977",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization of the upload mechanism is leads to stored XSS."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.barco.com/en/support/transform-n-management-server",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"name": "https://www.barco.com/en/support/knowledge-base/KB12683",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/knowledge-base/KB12683"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-26977",
"datePublished": "2022-06-01T11:35:16.000Z",
"dateReserved": "2022-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-03T05:18:39.263Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26976 (GCVE-0-2022-26976)
Vulnerability from cvelistv5 – Published: 2022-06-01 11:35 – Updated: 2024-08-03 05:18- n/a
| URL | Tags |
|---|---|
| https://www.barco.com/en/support/transform-n-mana… | x_refsource_MISC |
| https://www.barco.com/en/support/knowledge-base/KB12682 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:18:39.221Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12682"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization in the upload mechanism is leads to reflected XSS."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-01T11:35:06.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12682"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-26976",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization in the upload mechanism is leads to reflected XSS."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.barco.com/en/support/transform-n-management-server",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"name": "https://www.barco.com/en/support/knowledge-base/KB12682",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/knowledge-base/KB12682"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-26976",
"datePublished": "2022-06-01T11:35:06.000Z",
"dateReserved": "2022-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-03T05:18:39.221Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26975 (GCVE-0-2022-26975)
Vulnerability from cvelistv5 – Published: 2022-06-01 11:34 – Updated: 2024-08-03 05:18- n/a
| URL | Tags |
|---|---|
| https://www.barco.com/en/support/transform-n-mana… | x_refsource_MISC |
| https://www.barco.com/en/support/knowledge-base/KB12677 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:18:39.305Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12677"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing log files without authentication."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-01T11:34:59.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.barco.com/en/support/knowledge-base/KB12677"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-26975",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing log files without authentication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.barco.com/en/support/transform-n-management-server",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/transform-n-management-server"
},
{
"name": "https://www.barco.com/en/support/knowledge-base/KB12677",
"refsource": "MISC",
"url": "https://www.barco.com/en/support/knowledge-base/KB12677"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-26975",
"datePublished": "2022-06-01T11:34:59.000Z",
"dateReserved": "2022-03-12T00:00:00.000Z",
"dateUpdated": "2024-08-03T05:18:39.305Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}