Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    2 vulnerabilities by EKEN

    CVE-2025-56675 (GCVE-0-2025-56675)

    Vulnerability from nvd – Published: 2025-09-30 00:00 – Updated: 2025-09-30 19:32
    VLAI
    Summary
    The EKEN video doorbell T6 BT60PLUS_MAIN_V1.0_GC1084_20230531 periodically sends debug logs to the EKEN cloud servers with sensitive information such as the Wi-Fi SSID and password.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-669 - Incorrect Resource Transfer Between Spheres
    Assigner
    Impacted products
    Vendor Product Version
    EKEN video doorbell T6 Affected: BT60PLUS_MAIN_V1.0_GC1084_20230531 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-56675",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-30T19:31:48.904405Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-30T19:32:42.572Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "video doorbell T6",
              "vendor": "EKEN",
              "versions": [
                {
                  "status": "affected",
                  "version": "BT60PLUS_MAIN_V1.0_GC1084_20230531",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The EKEN video doorbell T6 BT60PLUS_MAIN_V1.0_GC1084_20230531 periodically sends debug logs to the EKEN cloud servers with sensitive information such as the Wi-Fi SSID and password."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 3.5,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-669",
                  "description": "CWE-669 Incorrect Resource Transfer Between Spheres",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-30T18:03:58.849Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://httpscolonforwardslashforwardslashwwwdotzoltanbalazsdotcom.com/2025/07/15/eken-wifi-leak.html"
            }
          ],
          "x_generator": {
            "engine": "enrichogram 0.0.1"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-56675",
        "datePublished": "2025-09-30T00:00:00.000Z",
        "dateReserved": "2025-08-17T00:00:00.000Z",
        "dateUpdated": "2025-09-30T19:32:42.572Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-56675 (GCVE-0-2025-56675)

    Vulnerability from cvelistv5 – Published: 2025-09-30 00:00 – Updated: 2025-09-30 19:32
    VLAI
    Summary
    The EKEN video doorbell T6 BT60PLUS_MAIN_V1.0_GC1084_20230531 periodically sends debug logs to the EKEN cloud servers with sensitive information such as the Wi-Fi SSID and password.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-669 - Incorrect Resource Transfer Between Spheres
    Assigner
    Impacted products
    Vendor Product Version
    EKEN video doorbell T6 Affected: BT60PLUS_MAIN_V1.0_GC1084_20230531 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-56675",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-30T19:31:48.904405Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-30T19:32:42.572Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "video doorbell T6",
              "vendor": "EKEN",
              "versions": [
                {
                  "status": "affected",
                  "version": "BT60PLUS_MAIN_V1.0_GC1084_20230531",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The EKEN video doorbell T6 BT60PLUS_MAIN_V1.0_GC1084_20230531 periodically sends debug logs to the EKEN cloud servers with sensitive information such as the Wi-Fi SSID and password."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 3.5,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-669",
                  "description": "CWE-669 Incorrect Resource Transfer Between Spheres",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-30T18:03:58.849Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://httpscolonforwardslashforwardslashwwwdotzoltanbalazsdotcom.com/2025/07/15/eken-wifi-leak.html"
            }
          ],
          "x_generator": {
            "engine": "enrichogram 0.0.1"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-56675",
        "datePublished": "2025-09-30T00:00:00.000Z",
        "dateReserved": "2025-08-17T00:00:00.000Z",
        "dateUpdated": "2025-09-30T19:32:42.572Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }