Vulnerabilites related to siemens - simatic_winac_rtx_f_2010
Vulnerability from fkie_nvd
Published
2017-12-26 04:29
Modified
2024-11-21 03:10
Severity ?
Summary
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E1170E1-3978-4B26-AE20-0B2E8F4C379B", "versionEndExcluding": "2.03.01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "BAD1D073-B29D-42CE-AF5E-B1AEF3DF09E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400pn_v6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E9296EA6-7EB3-4661-9024-C5E435E5E5DF", "versionEndExcluding": "6.0.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400pn_v6:-:*:*:*:*:*:*:*", "matchCriteriaId": "FA55DDD2-92C5-4A73-A75D-F13A7B720A22", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0DF482D-78BF-418E-8299-45E7C11C0F64", "versionEndExcluding": "6.0.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*", "matchCriteriaId": "1D082EB6-3C13-40C1-9949-179DC59037C1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400pn\\/dp_v7_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29A41A6-33ED-4E2E-9613-13FF0A521C1A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400pn\\/dp_v7:-:*:*:*:*:*:*:*", "matchCriteriaId": "66E6070F-9180-4FBC-A0DB-6AC8C242CADA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "7F211D16-8C72-4720-BD72-8273DB73BBA1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*", "matchCriteriaId": "926D9DCF-A7EA-416A-9A07-122D1FCA027B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "4C096137-C1E3-4D19-87A9-BEB7A081DD1E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD4E99-5C66-443F-8B6F-FA01C895DE78", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "5187EF42-3E86-4C73-A435-E5D5710B6999", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "32221F56-8BA2-4DAE-BBCB-B5EDC2813674", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_controller_firmware:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "9C92AE0F-3688-4DE7-8805-8C2B7E57A97A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*", "matchCriteriaId": "5E324C78-6911-412E-87D4-36A5BCA856EC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_f_2010_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2EA451CA-78D2-46D8-A3BA-419ACCB2E9D9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx_f_2010:-:*:*:*:*:*:*:*", "matchCriteriaId": "61527333-0741-42DE-9A68-BBC288526DD8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AD5A211-517E-40BE-B306-FE29F9CD3F67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*", "matchCriteriaId": "34C17B00-34B5-4A15-9333-252BE2975F37", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D281D261-AF1E-417B-9D86-2BC11B5D1231", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*", "matchCriteriaId": "0259EAE9-0CA0-49A5-A573-8339604A181B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D0BED0F6-86D0-43E0-AD49-F4F111245F39", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*", "matchCriteriaId": "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "DDF6E7E6-B323-4576-92AF-33FF3E5F3CE8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*", "matchCriteriaId": "49DA8715-D671-4D8F-A870-E61960A5AFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAFDDB1-7AF3-4665-B1AE-ED893245890A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "3F0CE2EC-9A73-4576-A389-A19893D47B0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1C194763-8D3D-490D-BF6C-B881581BB13B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1EC40E7-F004-446C-B5C9-0AB9911105E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "238BF3F4-3680-4138-A1F0-4034A614A41B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*", "matchCriteriaId": "691CA334-4394-4ED6-B417-F67FC92228AE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "ED030D86-261F-446C-A7AA-1B2CD3C0BF09", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*", "matchCriteriaId": "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D4EE8C83-8D16-447C-AF7C-4CF52438E932", "versionEndExcluding": "4.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*", "matchCriteriaId": "FB75CD44-5223-40A7-A835-111BF3C25D23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200pn_io_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "37947E71-645B-408D-B45B-A03214B46CEC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200pn_io:-:*:*:*:*:*:*:*", "matchCriteriaId": "36AA2F7C-ABCF-4F43-A595-49F8BDAD6336", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simotion_d_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5532645E-7937-4B07-8DE1-5CA04A57A852", "versionEndIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simotion_d:-:*:*:*:*:*:*:*", "matchCriteriaId": "F736C6F1-98CE-4C94-9457-4E1278B66C05", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simotion_c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5DFA690-68F5-461E-BD0E-E9813F0103D3", "versionEndIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simotion_c:-:*:*:*:*:*:*:*", "matchCriteriaId": "BA8EBFB0-47DE-495A-9971-B762BB519E0C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simotion_p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A71DD5C2-3127-48CC-A02E-3BD6C66DB8B3", "versionEndIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simotion_p:-:*:*:*:*:*:*:*", "matchCriteriaId": "AA14B83E-1438-46B9-B05E-DB9165DF9274", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "4004A6FB-C40C-484F-A0A2-485B6B617FF8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1A43D34-ECA3-4330-B85F-02BDD1D22149", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "713658D1-059F-478F-A950-3969EDD2EC6F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*", "matchCriteriaId": "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g110m\\/g120pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "22FF232D-AA38-481F-BA05-94BCD80A0E72", "versionEndIncluding": "4.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g110m\\/g120pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAD9F256-8342-45D2-9758-C24484CBE19D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2D52C517-17D7-467A-A021-9832DC8906F7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF9EA116-C2EF-487F-A9CD-8526B014AA77", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s110pn_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "BFA2F893-58D9-4445-9653-564291014A54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s110pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "763325DC-F62B-4F61-8A05-CA5C836EC990", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDA8B933-D7E3-4E3B-AA1D-75AFC89EA730", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s150_v4.7_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F961DB8C-4602-4B25-8CBC-F61413F48C40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s150_v4.7:-:*:*:*:*:*:*:*", "matchCriteriaId": "E0D975BB-137E-415B-9D0A-C3B68C3FD16A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s150_v4.8_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "63DC04F5-D4C9-4FD7-BA26-ACD9B6B6E91B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s150_v4.8:-:*:*:*:*:*:*:*", "matchCriteriaId": "90FA0B11-B161-4516-9D4F-9D3CEABB71BA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_v90pn_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "66B06805-BAAA-46A8-9FCD-03876ED5D079", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_v90pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "0CB3D335-F7F5-4CEA-82E0-FF56762E984C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "705AA5C8-E884-479D-972E-C779B6D0542B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*", "matchCriteriaId": "765286DF-07EC-4C7A-AB8C-09559CD977EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_compact_field_unit_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "B18BCB76-61B2-4573-8EBF-EB61B597B7E4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_compact_field_unit:-:*:*:*:*:*:*:*", "matchCriteriaId": "933FF731-95FA-4A32-80DC-47CD806144D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "6086ACE6-B396-4954-80E8-EDD167DF2021", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*", "matchCriteriaId": "49FB85F8-7D45-433E-805B-360725F2980C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "BD292574-20C0-432B-8BE7-3893077DC3FD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "352651A0-F7CE-4689-8597-15F3764707A9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44pn_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "44C18078-18D3-445F-B67B-B21BE6B6A44B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "336625A5-CADB-4F33-B49F-ACA4D4B4EDEC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Development/Evaluation Kits para PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incluidas las variantes SIPLUS), SIMATIC ET200MP IM155-5 PN BA (incluidas las variantes SIPLUS), SIMATIC ET200MP IM155-5 PN HF (incluidas las variantes SIPLUS), SIMATIC ET200MP IM155-5 PN ST (incluidas las variantes SIPLUS), SIMATIC ET200S (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN BA (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HA (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HS (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN ST (incluidas las variantes SIPLUS), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, SIMATIC PN/PN Coupler (incluidas las variantes SIPLUS NET), familia SIMATIC S7-1200 CPU (incluidas las variantes SIPLUS), familia SIMATIC S7-1500 CPU (incluyendo las variantes relacionadas ET200 CPUs y SIPLUS), SIMATIC S7-1500 Software Controller, SIMATIC S7-200 SMART, familia SIMATIC S7-300 CPU (incluyendo las variantes relacionadas ET200 CPUs y SIPLUS), SIMATIC S7-400 H V6 CPU familia y posteriores (incluidas las variantes SIPLUS), SIMATIC S7-400 PN/DP V6 CPU familia y posteriores (incluidas las variantes SIPLUS), familia SIMATIC S7-400 PN/DP V7 CPU (incluidas las variantes SIPLUS), familia SIMATIC S7-410 V8 CPU (incluidas las variantes SIPLUS), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SIMOCODE pro V EIP (incluidas las variantes SIPLUS), SIMOCODE pro V PN (incluidas las variantes SIPLUS), SIMOTION C, SIMOTION D (incluidas las variantes SIPLUS), SIMOTION D4xx V4.4 para SINAMICS SM150i-2 w. PROFINET (incluidas las variantes SIPLUS), SIMOTION P V4.4 and V4.5, SIMOTION P V5, SINAMICS DCM w. PN, SINAMICS DCP w. PN, SINAMICS G110M w. PN, SINAMICS G120(C/P/D) w. PN (incluidas las variantes SIPLUS), SINAMICS G130 V4.7 w. PN, SINAMICS G130 V4.8 w. PN, SINAMICS G150 V4.7 w. PN, SINAMICS G150 V4.8 w. PN, SINAMICS GH150 V4.7 w. PROFINET, SINAMICS GL150 V4.7 w. PROFINET, SINAMICS GM150 V4.7 w. PROFINET, SINAMICS S110 w. PN, SINAMICS S120 V4.7 SP1 w. PN (incluidas las variantes SIPLUS), SINAMICS S120 V4.7 w. PN (incluidas las variantes SIPLUS), SINAMICS S120 V4.8 w. PN (incluidas las variantes SIPLUS), SINAMICS S120 prior to V4.7 w. PN (incluidas las variantes SIPLUS), SINAMICS S150 V4.7 w. PN, SINAMICS S150 V4.8 w. PN, SINAMICS SL150 V4.7.0 w. PROFINET, SINAMICS SL150 V4.7.4 w. PROFINET, SINAMICS SL150 V4.7.5 w. PROFINET, SINAMICS SM120 V4.7 w. PROFINET, SINAMICS V90 w. PN, SINUMERIK 840D sl, SIRIUS Soft Starter 3RW44 PN. Los paquetes especialmente creados enviados al puerto 161/UDP podr\u00edan generar una condici\u00f3n de denegaci\u00f3n de servicio. Los dispositivos afectados deben reiniciarse manualmente" } ], "id": "CVE-2017-12741", "lastModified": "2024-11-21T03:10:07.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE" }, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2017-12-26T04:29:13.707", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "source": "productcert@siemens.com", "url": "https://www.securityfocus.com/bid/101964" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.securityfocus.com/bid/101964" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2016-11-15 19:30
Modified
2024-11-21 02:57
Severity ?
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent).
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html | Third Party Advisory | |
cve@mitre.org | http://www.securityfocus.com/bid/94158 | Third Party Advisory, VDB Entry | |
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf | ||
cve@mitre.org | https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/94158 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf | ||
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:primary_setup_tool:-:*:*:*:*:*:*:*", "matchCriteriaId": "8046A64D-4C80-4199-B1A7-F77D02428ACD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:security_configuration_tool:-:*:*:*:*:*:*:*", "matchCriteriaId": "C33765E4-619E-4566-BF96-4A7C8776A0CB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_production_suite:-:*:*:*:*:*:*:*", "matchCriteriaId": "DBCAF7A5-CA65-4D88-8473-67947726CA2D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "87DF85DE-B86C-459A-A9A9-096AF7A661E6", "versionEndIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "4DFBFF6B-DBC8-451D-A235-4C7E1F0883D5", "versionEndIncluding": "7.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "E8B894F4-9635-4436-BC0A-E43280426017", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.1:*:*:*:*:*:*:*", "matchCriteriaId": "172A6A81-C32E-4ACC-AB8C-2014BF3A6901", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.2:*:*:*:*:*:*:*", "matchCriteriaId": "8C6E8BBF-C5FF-4F13-AC70-2FF41CF3CC8E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:sp4:*:*:*:*:*:*", "matchCriteriaId": "C60C6533-1875-4E5B-A367-F6C1C1345CCF", "versionEndIncluding": "5.5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):*:*:*:*:*:*:*:*", "matchCriteriaId": "A4053231-D271-4A23-B0A0-374F6EAE2EF8", "versionEndIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*", "matchCriteriaId": "AD93D757-C2DE-444C-9FF4-A7A700EFF7F0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_winac_rtx_f_2010:-:*:*:*:*:*:*:*", "matchCriteriaId": "042D7AB5-8DB7-478E-8CB8-31942D360B34", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:sp2:*:*:*:*:*:*", "matchCriteriaId": "B9D3442E-E362-49BA-8699-629A611A6E2E", "versionEndIncluding": "7.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*", "matchCriteriaId": "0D0BB2E6-1444-499A-943E-8D19C402F1BD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:*:*:*:*:*:*:*", "matchCriteriaId": "4C4BFBED-E818-453C-B787-22D67B4A5A29", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*", "matchCriteriaId": "8D6229A2-9B8E-4F76-8425-589D2CE58B16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*", "matchCriteriaId": "F64B795A-7E66-49AE-BE40-E8EEAC12D280", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:advanced:*:*:*", "matchCriteriaId": "882F53D9-7AAA-4647-B071-A45CA2618AA1", "versionEndIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:basic:*:*:*", "matchCriteriaId": "F4524CA7-833B-4577-A5E5-DB47704F49AF", "versionEndIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:comfort:*:*:*", "matchCriteriaId": "58782A2B-6A27-475A-9FAB-0272DED5DB40", "versionEndIncluding": "14.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):-:*:*:*:professional:*:*:*", "matchCriteriaId": "D9BA6A34-593E-466A-B11B-1E2DC890ECF6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*", "matchCriteriaId": "E6BFBAED-EE2B-4DE4-A76C-824DD15F4608", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simit:9.0:*:*:*:*:*:*:*", "matchCriteriaId": "939DE56D-D8D7-42B8-BC0C-D6727E99AFA3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_remote_connect:-:*:*:*:*:*:*:*", "matchCriteriaId": "9646F056-080A-4F45-AABD-4D6E8AF05148", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:*:sp2:*:*:*:*:*:*", "matchCriteriaId": "3F8B6E52-C339-41B9-A2C1-A6D161251648", "versionEndIncluding": "13.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:softnet_security_client:*:*:*:*:*:*:*:*", "matchCriteriaId": "18BFF869-4E4E-4410-91F7-56A7E959C0FE", "versionEndIncluding": "5.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:telecontrol_basic:*:sp2:*:*:*:*:*:*", "matchCriteriaId": "A9386816-33A5-4DA7-931B-841AAE40E3BE", "versionEndIncluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Primary Setup Tool (PST) (todas las versiones anteriores a V4.2 HF1), SIMATIC IT Production Suite (todas las versiones anteriores a V7.0 SP1 HFX 2), SIMATIC NET PC-Software (Todas las versiones anteriores a V14), SIMATIC PCS 7 versi\u00f3n V7.1 (Todas las versiones), SIMATIC PCS 7 versi\u00f3n V8.0 (Todas las versiones), SIMATIC PCS 7 versi\u00f3n V8.1 (Todas las versiones),SIMATIC PCS 7 versi\u00f3n V8.2 (Todas las versiones anteriores a V8.2 SP1), SIMATIC STEP 7 (TIA Portal) versi\u00f3n V13 (Todas las versiones anteriores a V13 SP2), SIMATIC STEP 7 versiones V5.X (Todas las versiones anteriores a V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (Todas las versiones anteriores a V14), SIMATIC WinCC (TIA Portal) Professional versi\u00f3n V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC (TIA Portal) Professional versi\u00f3n V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC Runtime Professional versi\u00f3n V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC Runtime Professional versi\u00f3n V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC versi\u00f3n V7.0 SP2 y anteriores (Todas las versiones anteriores a V7.0 SP2 Upd 12), SIMATIC WinCC versi\u00f3n V7.0 SP3 (Todas las versiones anteriores a V7.0 SP3 Upd 8), SIMATIC WinCC versi\u00f3n V7.2 (Todas las versiones anteriores a V7.2 Upd 14), SIMATIC WinCC versi\u00f3n V7.3 (Todas las versiones anteriores a V7.3 Upd 11), SIMATIC WinCC versi\u00f3n V7.4 (Todas las versiones anteriores a V7.4 SP1), SIMIT versi\u00f3n V9.0 (Todas las versiones anteriores a V9.0 SP1), SINEMA Remote Connect Client (Todas las versiones anteriores a V1.0 SP3), SINEMA Server (Todas las versiones anteriores a V13 SP2), SOFTNET Security Client versi\u00f3n V5.0 (Todas las versiones), Security Configuration Tool (SCT) (Todas las versiones anteriores a V4.3 HF1), TeleControl Server Basic (Todas las versiones anteriores a V3.0 SP2), WinAC RTX 2010 SP2 (Todas las versiones), WinAC RTX F 2010 SP2 (Todas las versiones). Las rutas (path) de servicio sin comillas podr\u00edan permitir que los usuarios locales del sistema operativo Microsoft Windows aumenten sus privilegios si los productos afectados no est\u00e1n instalados en su ruta (path) de acceso predeterminada (\"C:\\Program Files\\*\" o el equivalente localizado)." } ], "id": "CVE-2016-7165", "lastModified": "2024-11-21T02:57:37.740", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 6.9, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.4, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 0.5, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2016-11-15T19:30:02.797", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/94158" }, { "source": "cve@mitre.org", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/94158" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-254" }, { "lang": "en", "value": "CWE-284" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2017-05-11 10:29
Modified
2024-11-21 03:30
Severity ?
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:pcs_7:-:*:*:*:*:*:*:*", "matchCriteriaId": "399B0B7B-17F7-463C-A124-5DE77337E212", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:primary_setup_tool:-:*:*:*:*:*:*:*", "matchCriteriaId": "8046A64D-4C80-4199-B1A7-F77D02428ACD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:security_configuration_tool:-:*:*:*:*:*:*:*", "matchCriteriaId": "C33765E4-619E-4566-BF96-4A7C8776A0CB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_automation_tool:-:*:*:*:*:*:*:*", "matchCriteriaId": "5306C1B1-5944-49F1-8BEC-5F811C891BED", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc-software:-:*:*:*:*:*:*:*", "matchCriteriaId": "6BE3E184-1158-488C-A689-34C70C6861F4", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):5.0:*:*:*:*:*:*:*", "matchCriteriaId": "3F096B1D-366B-4E2E-A03F-607559623FE8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):13.0:*:*:*:*:*:*:*", "matchCriteriaId": "32A02189-0785-4A64-BC00-830733F21792", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):14.0:*:*:*:*:*:*:*", "matchCriteriaId": "62D57BAA-A31B-4369-837D-90796779C487", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7_micro\\/win_smart:-:*:*:*:*:*:*:*", "matchCriteriaId": "00CA4054-615D-4821-909A-411E4BCD3D06", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:sp2:*:*:*:*:*:*", "matchCriteriaId": "9D74E76A-5EE5-41AE-9C56-742EC9AD1408", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_winac_rtx_f_2010:-:sp2:*:*:*:*:*:*", "matchCriteriaId": "FB81FD88-3D70-4413-B035-93A3D5389170", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F7BB505-A6B6-4200-9602-E4D348E407AB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):13.0:*:*:*:*:*:*:*", "matchCriteriaId": "E3D1A823-CE50-441F-B060-DA678DFE24FD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):14.0:*:*:*:*:*:*:*", "matchCriteriaId": "28A1BA01-7A92-4368-8A73-8FA47A08BC53", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_flexible_2008:-:*:*:*:*:*:*:*", "matchCriteriaId": "E2429ABE-55D8-4E6D-89EB-CE016B9336ED", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinaut_st7cc:-:*:*:*:*:*:*:*", "matchCriteriaId": "0BCB1BDC-91E7-48DC-85BA-45A2B5B840B0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinema_server:-:*:*:*:*:*:*:*", "matchCriteriaId": "DCC74BDB-87BD-40E1-8426-0353266F194E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_808d_programming_tool:-:*:*:*:*:*:*:*", "matchCriteriaId": "B82B7F7E-C9D4-4B31-9482-41BF35C8F470", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:smart_pc_access:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "F54273D3-5C43-4343-B71F-FAD16A5CEF50", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC Automation Tool (All versions \u003c V3.0), SIMATIC NET PC-Software (All versions \u003c V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC STEP 7 V5.X (All versions \u003c V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Update 15), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions \u003c flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15), SINEMA Server (All versions \u003c V14), SINUMERIK 808D Programming Tool (All versions \u003c V4.7 SP4 HF2), SMART PC Access (All versions \u003c V2.3), STEP 7 - Micro/WIN SMART (All versions \u003c V2.3), Security Configuration Tool (SCT) (All versions \u003c V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Primary Setup Tool (PST) (todas las versiones 4.2 HF1), SIMATIC Automation Tool (todas las versiones 3.0), SIMATIC NET PC-software (todas las versiones 14 SP1), SIMATIC PCS 7 Versi\u00f3n 8.1 (todas las versiones), SIMATIC PCS 7 Versi\u00f3n 8.2 (todas las versiones 8.2 SP1), SIMATIC STEP Versi\u00f3n 7 (TIA Portal) Versi\u00f3n 13 (todas las versiones 13 SP2), SIMATIC STEP Versi\u00f3n 7 (TIA Portal) Versi\u00f3n 14 (todas las versiones 14 SP1), SIMATIC STEP 7 Versi\u00f3n 5.x (todas las versiones 5.6), SIMATIC WinAC RTX 2010 SP2 (todas las versiones), SIMATIC WinAC RTX F 2010 SP2 (todas versiones), SIMATIC WinCC (TIA Portal) Versi\u00f3n 13 (todas las versiones 13 SP2), SIMATIC WinCC (TIA Portal) Versi\u00f3n 14 (todas las versiones 14 SP1), SIMATIC WinCC Versi\u00f3n 7.2 y anteriores (todos versiones), SIMATIC WinCC Versi\u00f3n 7.3 (todas las versiones 7.3 actualizaci\u00f3n 15), SIMATIC WinCC Versi\u00f3n 7.4 (todas las versiones 7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (todas las versiones anteriores a flexible 2008 SP5), SINAUT ST7CC (todas las versiones instaladas en conjunto con SIMATIC WinCC Versi\u00f3n 7.3 actualizaci\u00f3n 15), SINEMA Server (todas las versiones 14), SINUMERIK 808D Programming Tool (todas las versiones 4.7 SP4 HF2), SMART PC Access (todas las versiones 2.3), STEP 7 - Micro/WIN SMART (todas las versiones 2.3), Security Configuration Tool (SCT) (todas las versiones 5.0). Los paquetes de difusi\u00f3n PROFINET DCP especialmente creados enviados a los productos afectados en un segmento Ethernet local (Layer 2) podr\u00edan causar una condici\u00f3n de denegaci\u00f3n de servicio de algunos servicios. Los servicios requieren el reinicio manual para recuperarse." } ], "id": "CVE-2017-6865", "lastModified": "2024-11-21T03:30:41.443", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2017-05-11T10:29:00.227", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf" }, { "source": "productcert@siemens.com", "url": "https://www.securityfocus.com/bid/98366" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.securityfocus.com/bid/98366" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2017-6865
Vulnerability from cvelistv5
Published
2017-05-11 10:00
Modified
2024-08-05 15:41
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf | x_refsource_CONFIRM | |
https://www.securityfocus.com/bid/98366 | vdb-entry, x_refsource_BID |
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens AG | Primary Setup Tool (PST) |
Version: All versions < V4.2 HF1 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T15:41:17.697Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf" }, { "name": "98366", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "https://www.securityfocus.com/bid/98366" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Primary Setup Tool (PST)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2 HF1" } ] }, { "product": "SIMATIC Automation Tool", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "product": "SIMATIC NET PC-Software", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1" } ] }, { "product": "SIMATIC PCS 7 V8.1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS 7 V8.2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2 SP1" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V13", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V14", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1" } ] }, { "product": "SIMATIC STEP 7 V5.X", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V5.6" } ] }, { "product": "SIMATIC WinAC RTX 2010 SP2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC WinAC RTX F 2010 SP2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC WinCC (TIA Portal) V13", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2" } ] }, { "product": "SIMATIC WinCC (TIA Portal) V14", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1" } ] }, { "product": "SIMATIC WinCC V7.2 and prior", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC WinCC V7.3", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V7.3 Update 15" } ] }, { "product": "SIMATIC WinCC V7.4", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Upd1" } ] }, { "product": "SIMATIC WinCC flexible 2008", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c flexible 2008 SP5" } ] }, { "product": "SINAUT ST7CC", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15" } ] }, { "product": "SINEMA Server", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V14" } ] }, { "product": "SINUMERIK 808D Programming Tool", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF2" } ] }, { "product": "SMART PC Access", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "product": "STEP 7 - Micro/WIN SMART", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "product": "Security Configuration Tool (SCT)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V5.0" } ] }, { "product": "Security Configuration Tool (SCT)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V5.0" } ] } ], "datePublic": "2017-05-10T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC Automation Tool (All versions \u003c V3.0), SIMATIC NET PC-Software (All versions \u003c V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC STEP 7 V5.X (All versions \u003c V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Update 15), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions \u003c flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15), SINEMA Server (All versions \u003c V14), SINUMERIK 808D Programming Tool (All versions \u003c V4.7 SP4 HF2), SMART PC Access (All versions \u003c V2.3), STEP 7 - Micro/WIN SMART (All versions \u003c V2.3), Security Configuration Tool (SCT) (All versions \u003c V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover." } ], "problemTypes": [ { "descriptions": [ { "description": "Other", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-03-21T15:44:20", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf" }, { "name": "98366", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "https://www.securityfocus.com/bid/98366" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2017-6865", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Primary Setup Tool (PST)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.2 HF1" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC Automation Tool", "version": { "version_data": [ { "version_value": "All versions \u003c V3.0" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC NET PC-Software", "version": { "version_data": [ { "version_value": "All versions \u003c V14 SP1" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC PCS 7 V8.1", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC PCS 7 V8.2", "version": { "version_data": [ { "version_value": "All versions \u003c V8.2 SP1" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC STEP 7 (TIA Portal) V13", "version": { "version_data": [ { "version_value": "All versions \u003c V13 SP2" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC STEP 7 (TIA Portal) V14", "version": { "version_data": [ { "version_value": "All versions \u003c V14 SP1" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC STEP 7 V5.X", "version": { "version_data": [ { "version_value": "All versions \u003c V5.6" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC WinAC RTX 2010 SP2", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC WinAC RTX F 2010 SP2", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC WinCC (TIA Portal) V13", "version": { "version_data": [ { "version_value": "All versions \u003c V13 SP2" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC WinCC (TIA Portal) V14", "version": { "version_data": [ { "version_value": "All versions \u003c V14 SP1" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC WinCC V7.2 and prior", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC WinCC V7.3", "version": { "version_data": [ { "version_value": "All versions \u003c V7.3 Update 15" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC WinCC V7.4", "version": { "version_data": [ { "version_value": "All versions \u003c V7.4 SP1 Upd1" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SIMATIC WinCC flexible 2008", "version": { "version_data": [ { "version_value": "All versions \u003c flexible 2008 SP5" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SINAUT ST7CC", "version": { "version_data": [ { "version_value": "All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SINEMA Server", "version": { "version_data": [ { "version_value": "All versions \u003c V14" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SINUMERIK 808D Programming Tool", "version": { "version_data": [ { "version_value": "All versions \u003c V4.7 SP4 HF2" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "SMART PC Access", "version": { "version_data": [ { "version_value": "All versions \u003c V2.3" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "STEP 7 - Micro/WIN SMART", "version": { "version_data": [ { "version_value": "All versions \u003c V2.3" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "Security Configuration Tool (SCT)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.0" } ] } } ] }, "vendor_name": "Siemens AG" }, { "product": { "product_data": [ { "product_name": "Security Configuration Tool (SCT)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.0" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC Automation Tool (All versions \u003c V3.0), SIMATIC NET PC-Software (All versions \u003c V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC STEP 7 V5.X (All versions \u003c V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Update 15), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions \u003c flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15), SINEMA Server (All versions \u003c V14), SINUMERIK 808D Programming Tool (All versions \u003c V4.7 SP4 HF2), SMART PC Access (All versions \u003c V2.3), STEP 7 - Micro/WIN SMART (All versions \u003c V2.3), Security Configuration Tool (SCT) (All versions \u003c V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Other" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf" }, { "name": "98366", "refsource": "BID", "url": "https://www.securityfocus.com/bid/98366" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-6865", "datePublished": "2017-05-11T10:00:00", "dateReserved": "2017-03-13T00:00:00", "dateUpdated": "2024-08-05T15:41:17.697Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-12741
Vulnerability from cvelistv5
Published
2017-12-26 04:00
Modified
2024-08-05 18:51
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T18:51:06.315Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "101964", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "https://www.securityfocus.com/bid/101964" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1 Patch 05" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Compact Field Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V1.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-200 SMART", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.03.01" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.X.16", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6\u00a0and below\u00a0CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 HF26" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION P V4.4 and V4.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 HF5" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION P V5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.4 SP1 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP9 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP9 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF29" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF29" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP5 HF7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF31" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 SP3 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF29" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF29" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.0 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF30" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.4 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.5 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.02" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Soft Starter 3RW44 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:03:53.948Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "101964", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "https://www.securityfocus.com/bid/101964" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-12741", "datePublished": "2017-12-26T04:00:00", "dateReserved": "2017-08-09T00:00:00", "dateUpdated": "2024-08-05T18:51:06.315Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2016-7165
Vulnerability from cvelistv5
Published
2016-11-15 19:00
Modified
2024-08-06 01:50
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent).
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02 | x_refsource_MISC | |
http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html | x_refsource_MISC | |
http://www.securityfocus.com/bid/94158 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T01:50:47.526Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html" }, { "name": "94158", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/94158" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2016-11-07T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-06-14T20:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02" }, { "tags": [ "x_refsource_MISC" ], "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html" }, { "name": "94158", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/94158" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2016-7165", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02" }, { "name": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html", "refsource": "MISC", "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html" }, { "name": "94158", "refsource": "BID", "url": "http://www.securityfocus.com/bid/94158" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2016-7165", "datePublished": "2016-11-15T19:00:00", "dateReserved": "2016-09-08T00:00:00", "dateUpdated": "2024-08-06T01:50:47.526Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }