Vulnerabilites related to wago - knx_ip
cve-2019-10953
Vulnerability from cvelistv5
Published
2019-04-17 14:02
Modified
2024-08-04 22:40
Severity ?
Summary
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.294Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03"
          },
          {
            "name": "108413",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/108413"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Multiple"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "UNCONTROLLED RESOURCE CONSUMPTION CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-22T15:06:03",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03"
        },
        {
          "name": "108413",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/108413"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-10953",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Multiple"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "UNCONTROLLED RESOURCE CONSUMPTION CWE-400"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03"
            },
            {
              "name": "108413",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/108413"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-10953",
    "datePublished": "2019-04-17T14:02:15",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.294Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2019-04-17 15:29
Modified
2024-11-21 04:20
Summary
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
References



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:abb:pm554-tp-eth_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "847F4C95-9AB3-425F-A878-4DC195DBD668",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:abb:pm554-tp-eth:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BBE1207A-9B60-47B4-A746-DC152ED24077",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc_151_eth_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB358CEE-2B29-4DAB-A100-36C841718D56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc_151_eth:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "301BA6C4-3E50-46CC-A6C9-E61948994F20",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:modicon_m221_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F757A52E-2401-4A09-B53E-73135C5289A1",
              "versionEndExcluding": "1.10.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:modicon_m221:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB0D83F4-B718-47AB-AFB8-B576CB138AAC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7211-1ae40-0xb0_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B034C67-6905-4A7F-8ADC-DACC0B73BB8E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7211-1ae40-0xb0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "70357AB0-8076-48BD-AB43-8D7AB53A0722",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7314-6eh04-0ab0_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "42683ED6-7FA5-41BD-AA18-F356BDD3D4DC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7314-6eh04-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "577E4267-C1E8-4DBD-BADF-ABCD7234665A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ed1052-1cc01-0ba8_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5757EF80-9057-4179-89BC-7C1A86CE84D8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ed1052-1cc01-0ba8:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "60C0A7A2-8492-42F1-A3D9-013137887FA7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:wago:knx_ip_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E13BFBE3-A566-445C-BEE0-0BB8F39A6F42",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:wago:knx_ip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E24D4135-A691-479E-963A-0ED39670CEC4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:wago:pfc100_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "08D508EF-AF32-4987-B3FF-D1A9EFEC94D0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:wago:pfc100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F636354-95A2-4B36-9666-1FA57F185432",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:wago:ethernet_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "111D5C0E-9346-4553-9D12-3453BA5F70B0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:wago:ethernet:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "91B48D8E-F0DD-4B6B-91D9-9B5FFF715FFD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:wago:bacnet\\/ip_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6BEBE22-0480-4513-9550-508EB52FBE03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:wago:bacnet\\/ip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AB69F49-EC3E-4EA4-8DCE-53C04166505E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets."
    },
    {
      "lang": "es",
      "value": "En Controladores l\u00f3gicos programables de ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - , versiones m\u00faltiples. Los investigadores han encontrado que algunos controladores son susceptibles a un ataque de Denegaci\u00f3n de Servicio (DoS) debido a una inundaci\u00f3n de paquetes de red."
    }
  ],
  "id": "CVE-2019-10953",
  "lastModified": "2024-11-21T04:20:13.450",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-04-17T15:29:00.843",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/108413"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/108413"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-770"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}