Vulnerabilites related to ge - intelligent_platforms_proficy_batch_execution
Vulnerability from fkie_nvd
Published
2012-07-05 03:23
Modified
2024-11-21 01:39
Severity ?
Summary
Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method.
References
ics-cert@hq.dhs.govhttp://retrogod.altervista.org/9sg_emc_keyhelp.htmlExploit
ics-cert@hq.dhs.govhttp://secunia.com/advisories/36905Vendor Advisory
ics-cert@hq.dhs.govhttp://secunia.com/advisories/36914Vendor Advisory
ics-cert@hq.dhs.govhttp://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdfVendor Advisory
ics-cert@hq.dhs.govhttp://www.securityfocus.com/bid/36546Exploit
ics-cert@hq.dhs.govhttp://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdfUS Government Resource
ics-cert@hq.dhs.govhttp://www.vupen.com/english/advisories/2009/2793
ics-cert@hq.dhs.govhttp://www.vupen.com/english/advisories/2009/2795
af854a3a-2127-422b-91ae-364da2661108http://retrogod.altervista.org/9sg_emc_keyhelp.htmlExploit
af854a3a-2127-422b-91ae-364da2661108http://secunia.com/advisories/36905Vendor Advisory
af854a3a-2127-422b-91ae-364da2661108http://secunia.com/advisories/36914Vendor Advisory
af854a3a-2127-422b-91ae-364da2661108http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdfVendor Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.securityfocus.com/bid/36546Exploit
af854a3a-2127-422b-91ae-364da2661108http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdfUS Government Resource
af854a3a-2127-422b-91ae-364da2661108http://www.vupen.com/english/advisories/2009/2793
af854a3a-2127-422b-91ae-364da2661108http://www.vupen.com/english/advisories/2009/2795



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:emc:captiva_quickscan_pro:4.6:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "8B464AC4-7766-47DB-AE36-1E26D244EC67",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:emc:documentum_applicationxtender_desktop:5.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "A361D413-79A2-492B-A675-7A40023BC0D7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_batch_execution:5.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D91A768-D643-4601-B11D-2C5FB60B8566",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "612B7F05-3C6D-43CA-8D6C-F0A887789EF5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:3.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D29C00B-B754-47C5-BBD0-D63DDD252DA6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BC9F852-EA9A-497D-9ED2-DAF926D0440A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:4.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C8C84F4-699E-4D77-AF36-19DF28AE16CC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_ifix:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "65A4CBC3-3B98-4700-8710-4D4FFCA55315",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_ifix:5.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "5ABA340B-B00B-41EC-8270-68139B63D09A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_pulse:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "738ACF30-4F1A-44C6-9A97-46F5566ACC05",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_si7_i\\/o_driver:7.20:*:*:*:*:*:*:*",
              "matchCriteriaId": "641F3A0F-9E07-413D-869C-8E123636DD0A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_si7_i\\/o_driver:7.42:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA786450-C420-420A-9C5E-49D408B6B3C2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method."
    },
    {
      "lang": "es",
      "value": "M\u00faltiples desbordamientos de b\u00fafer en el control ActiveX KeyHelp.KeyCtrl.1 en KeyHelp.ocx v1.2.312 en KeyWorks KeyHelp Module (tambi\u00e9n conocido como el componente HTML Help), tal como se utiliza en EMC Documentum ApplicationXtender Desktop v5.4; EMC Captiva Quickscan Pro v4.6 SP1; GE Intelligent Platforms Proficy Historian v3.1, v3.5, v4.0 y v4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX v5.0 y v5.1; Proficy Pulse v1,0; Proficy Batch Execution v5,6, SI7 ??E/S Driverv 7.20 hasta 7.42, y otros productos, permite a atacantes remotos ejecutar c\u00f3digo de su elecci\u00f3n a trav\u00e9s de una larga cadena en el segundo argumento del m\u00e9todo (1) JumpMappedID o (2) JumpURL."
    }
  ],
  "id": "CVE-2012-2515",
  "lastModified": "2024-11-21T01:39:10.217",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.3,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2012-07-05T03:23:18.480",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Exploit"
      ],
      "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://secunia.com/advisories/36905"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://secunia.com/advisories/36914"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Exploit"
      ],
      "url": "http://www.securityfocus.com/bid/36546"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "http://www.vupen.com/english/advisories/2009/2793"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "http://www.vupen.com/english/advisories/2009/2795"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit"
      ],
      "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://secunia.com/advisories/36905"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://secunia.com/advisories/36914"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit"
      ],
      "url": "http://www.securityfocus.com/bid/36546"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.vupen.com/english/advisories/2009/2793"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.vupen.com/english/advisories/2009/2795"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2012-07-05 03:23
Modified
2024-11-21 01:39
Severity ?
Summary
An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module (aka the HTML Help component), as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other products, allows remote attackers to execute arbitrary commands via crafted input, related to a "command injection vulnerability."



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_batch_execution:5.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D91A768-D643-4601-B11D-2C5FB60B8566",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "612B7F05-3C6D-43CA-8D6C-F0A887789EF5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:3.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D29C00B-B754-47C5-BBD0-D63DDD252DA6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BC9F852-EA9A-497D-9ED2-DAF926D0440A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:4.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C8C84F4-699E-4D77-AF36-19DF28AE16CC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_ifix:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "65A4CBC3-3B98-4700-8710-4D4FFCA55315",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_ifix:5.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "5ABA340B-B00B-41EC-8270-68139B63D09A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_pulse:1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "738ACF30-4F1A-44C6-9A97-46F5566ACC05",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_si7_i\\/o_driver:7.20:*:*:*:*:*:*:*",
              "matchCriteriaId": "641F3A0F-9E07-413D-869C-8E123636DD0A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_si7_i\\/o_driver:7.42:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA786450-C420-420A-9C5E-49D408B6B3C2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module (aka the HTML Help component), as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other products, allows remote attackers to execute arbitrary commands via crafted input, related to a \"command injection vulnerability.\""
    },
    {
      "lang": "es",
      "value": "Un control ActiveX en KeyHelp.ocx en KeyWorks KeyHelp Module (tambi\u00e9n conocido como el componente HTML Help), tal como se utiliza en GE Intelligent Platforms Proficy Historian v3.1, v3.5, v4.0 y v4.5; Proficy HMI/SCADA iFIX v5.0 y v5.1; Proficy Pulse v1,0; Proficy Batch Execution v5,6, SI7 ??E/S Driverv 7.20 hasta 7.42, y otros productos, permite a atacantes remotos ejecutar comandos arbitrarios a trav\u00e9s de la entrada hecha a mano, relacionada con una \"vulnerabilidad de inyecci\u00f3n de comandos.\""
    }
  ],
  "id": "CVE-2012-2516",
  "lastModified": "2024-11-21T01:39:10.333",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.3,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2012-07-05T03:23:18.527",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2012-2515
Vulnerability from cvelistv5
Published
2012-07-05 01:00
Modified
2024-09-16 17:37
Severity ?
Summary
Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:34:25.874Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "ADV-2009-2795",
            "tags": [
              "vdb-entry",
              "x_refsource_VUPEN",
              "x_transferred"
            ],
            "url": "http://www.vupen.com/english/advisories/2009/2795"
          },
          {
            "name": "ADV-2009-2793",
            "tags": [
              "vdb-entry",
              "x_refsource_VUPEN",
              "x_transferred"
            ],
            "url": "http://www.vupen.com/english/advisories/2009/2793"
          },
          {
            "name": "36546",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/36546"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
          },
          {
            "name": "36914",
            "tags": [
              "third-party-advisory",
              "x_refsource_SECUNIA",
              "x_transferred"
            ],
            "url": "http://secunia.com/advisories/36914"
          },
          {
            "name": "36905",
            "tags": [
              "third-party-advisory",
              "x_refsource_SECUNIA",
              "x_transferred"
            ],
            "url": "http://secunia.com/advisories/36905"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-07-05T01:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "ADV-2009-2795",
          "tags": [
            "vdb-entry",
            "x_refsource_VUPEN"
          ],
          "url": "http://www.vupen.com/english/advisories/2009/2795"
        },
        {
          "name": "ADV-2009-2793",
          "tags": [
            "vdb-entry",
            "x_refsource_VUPEN"
          ],
          "url": "http://www.vupen.com/english/advisories/2009/2793"
        },
        {
          "name": "36546",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/36546"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
        },
        {
          "name": "36914",
          "tags": [
            "third-party-advisory",
            "x_refsource_SECUNIA"
          ],
          "url": "http://secunia.com/advisories/36914"
        },
        {
          "name": "36905",
          "tags": [
            "third-party-advisory",
            "x_refsource_SECUNIA"
          ],
          "url": "http://secunia.com/advisories/36905"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2012-2515",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "ADV-2009-2795",
              "refsource": "VUPEN",
              "url": "http://www.vupen.com/english/advisories/2009/2795"
            },
            {
              "name": "ADV-2009-2793",
              "refsource": "VUPEN",
              "url": "http://www.vupen.com/english/advisories/2009/2793"
            },
            {
              "name": "36546",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/36546"
            },
            {
              "name": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf",
              "refsource": "CONFIRM",
              "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
            },
            {
              "name": "36914",
              "refsource": "SECUNIA",
              "url": "http://secunia.com/advisories/36914"
            },
            {
              "name": "36905",
              "refsource": "SECUNIA",
              "url": "http://secunia.com/advisories/36905"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
            },
            {
              "name": "http://retrogod.altervista.org/9sg_emc_keyhelp.html",
              "refsource": "MISC",
              "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2012-2515",
    "datePublished": "2012-07-05T01:00:00Z",
    "dateReserved": "2012-05-07T00:00:00Z",
    "dateUpdated": "2024-09-16T17:37:55.554Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2012-2516
Vulnerability from cvelistv5
Published
2012-07-05 01:00
Modified
2024-09-16 21:03
Severity ?
Summary
An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module (aka the HTML Help component), as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other products, allows remote attackers to execute arbitrary commands via crafted input, related to a "command injection vulnerability."
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:34:25.829Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module (aka the HTML Help component), as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other products, allows remote attackers to execute arbitrary commands via crafted input, related to a \"command injection vulnerability.\""
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-07-05T01:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2012-2516",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module (aka the HTML Help component), as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other products, allows remote attackers to execute arbitrary commands via crafted input, related to a \"command injection vulnerability.\""
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf",
              "refsource": "CONFIRM",
              "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2012-2516",
    "datePublished": "2012-07-05T01:00:00Z",
    "dateReserved": "2012-05-07T00:00:00Z",
    "dateUpdated": "2024-09-16T21:03:23.845Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}