Vulnerabilites related to tenda - fh1205_firmware
cve-2024-3010
Vulnerability from cvelistv5
Published
2024-03-27 23:31
Modified
2024-08-23 18:30
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability was found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this issue is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258296. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.258296 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.258296 | signature, permissions-required | |
https://vuldb.com/?submit.301489 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formSetCfm.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.0.7\\(775\\)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3010", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-23T18:30:05.977488Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-23T18:30:19.870Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:32:42.588Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-258296 | Tenda FH1205 setcfm formSetCfm stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.258296" }, { "name": "VDB-258296 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.258296" }, { "name": "Submit #301489 | Tenda FH1205 V2.0.0.7(775) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.301489" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formSetCfm.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "FH1205", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.0.7(775)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_mie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this issue is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258296. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda FH1205 2.0.0.7(775) gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion formSetCfm der Datei /goform/setcfm. Mittels dem Manipulieren des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-27T23:31:05.075Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-258296 | Tenda FH1205 setcfm formSetCfm stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.258296" }, { "name": "VDB-258296 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.258296" }, { "name": "Submit #301489 | Tenda FH1205 V2.0.0.7(775) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.301489" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formSetCfm.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-27T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-27T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-27T15:21:07.000Z", "value": "VulDB entry last update" } ], "title": "Tenda FH1205 setcfm formSetCfm stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3010", "datePublished": "2024-03-27T23:31:05.075Z", "dateReserved": "2024-03-27T14:15:31.837Z", "dateUpdated": "2024-08-23T18:30:19.870Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-3009
Vulnerability from cvelistv5
Published
2024-03-27 23:31
Modified
2024-08-27 20:18
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
EPSS score ?
Summary
A vulnerability has been found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258295. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.258295 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.258295 | signature, permissions-required | |
https://vuldb.com/?submit.301488 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formWriteFacMac.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:32:42.572Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-258295 | Tenda FH1205 WriteFacMac formWriteFacMac command injection", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.258295" }, { "name": "VDB-258295 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.258295" }, { "name": "Submit #301488 | Tenda FH1205 V2.0.0.7(775) command injection", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.301488" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formWriteFacMac.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.0.7\\(775\\)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3009", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-03-28T18:30:14.178695Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-27T20:18:48.485Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "FH1205", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.0.7(775)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_mie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258295. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda FH1205 2.0.0.7(775) wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Es geht um die Funktion formWriteFacMac der Datei /goform/WriteFacMac. Durch Manipulation des Arguments mac mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.5, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77 Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-27T23:31:03.733Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-258295 | Tenda FH1205 WriteFacMac formWriteFacMac command injection", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.258295" }, { "name": "VDB-258295 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.258295" }, { "name": "Submit #301488 | Tenda FH1205 V2.0.0.7(775) command injection", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.301488" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formWriteFacMac.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-27T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-27T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-27T15:21:05.000Z", "value": "VulDB entry last update" } ], "title": "Tenda FH1205 WriteFacMac formWriteFacMac command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3009", "datePublished": "2024-03-27T23:31:03.733Z", "dateReserved": "2024-03-27T14:15:28.641Z", "dateUpdated": "2024-08-27T20:18:48.485Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-3007
Vulnerability from cvelistv5
Published
2024-03-27 23:00
Modified
2024-08-12 13:34
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7(775). This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258293 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.258293 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.258293 | signature, permissions-required | |
https://vuldb.com/?submit.301486 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromNatStaticSetting.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:32:42.523Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-258293 | Tenda FH1205 NatStaticSetting fromNatStaticSetting stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.258293" }, { "name": "VDB-258293 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.258293" }, { "name": "Submit #301486 | Tenda FH1205 V2.0.0.7(775) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.301486" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromNatStaticSetting.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.0.7\\(775\\)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3007", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-10T19:39:36.472013Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-12T13:34:36.150Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "FH1205", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.0.7(775)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_mie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7(775). This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258293 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda FH1205 2.0.0.7(775) entdeckt. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion fromNatStaticSetting der Datei /goform/NatStaticSetting. Mit der Manipulation des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-27T23:00:05.599Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-258293 | Tenda FH1205 NatStaticSetting fromNatStaticSetting stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.258293" }, { "name": "VDB-258293 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.258293" }, { "name": "Submit #301486 | Tenda FH1205 V2.0.0.7(775) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.301486" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromNatStaticSetting.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-27T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-27T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-27T15:21:02.000Z", "value": "VulDB entry last update" } ], "title": "Tenda FH1205 NatStaticSetting fromNatStaticSetting stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3007", "datePublished": "2024-03-27T23:00:05.599Z", "dateReserved": "2024-03-27T14:15:22.898Z", "dateUpdated": "2024-08-12T13:34:36.150Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-3012
Vulnerability from cvelistv5
Published
2024-03-28 00:00
Modified
2024-08-12 18:02
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been declared as critical. This vulnerability affects the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258298 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.258298 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.258298 | signature, permissions-required | |
https://vuldb.com/?submit.301491 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/GetParentControlInfo.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:32:42.503Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-258298 | Tenda FH1205 GetParentControlInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.258298" }, { "name": "VDB-258298 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.258298" }, { "name": "Submit #301491 | Tenda FH1205 V2.0.0.7(775) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.301491" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/GetParentControlInfo.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.0.7\\(775\\)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3012", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-12T15:14:37.213344Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-12T18:02:42.168Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "FH1205", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.0.7(775)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_mie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been declared as critical. This vulnerability affects the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258298 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda FH1205 2.0.0.7(775) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion GetParentControlInfo der Datei /goform/GetParentControlInfo. Durch das Manipulieren des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-28T00:00:06.995Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-258298 | Tenda FH1205 GetParentControlInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.258298" }, { "name": "VDB-258298 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.258298" }, { "name": "Submit #301491 | Tenda FH1205 V2.0.0.7(775) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.301491" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/GetParentControlInfo.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-27T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-27T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-27T15:21:10.000Z", "value": "VulDB entry last update" } ], "title": "Tenda FH1205 GetParentControlInfo stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3012", "datePublished": "2024-03-28T00:00:06.995Z", "dateReserved": "2024-03-27T14:15:41.280Z", "dateUpdated": "2024-08-12T18:02:42.168Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-3008
Vulnerability from cvelistv5
Published
2024-03-27 23:00
Modified
2024-08-01 19:32
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7(775). Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258294 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.258294 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.258294 | signature, permissions-required | |
https://vuldb.com/?submit.301487 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formexeCommand.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.0.7\\/775\\/" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3008", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-17T15:57:34.483846Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-17T15:59:52.535Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:32:42.533Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-258294 | Tenda FH1205 execCommand formexeCommand stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.258294" }, { "name": "VDB-258294 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.258294" }, { "name": "Submit #301487 | Tenda FH1205 V2.0.0.7(775) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.301487" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formexeCommand.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "FH1205", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.0.7(775)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_mie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7(775). Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258294 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda FH1205 2.0.0.7(775) gefunden. Sie wurde als kritisch eingestuft. Betroffen hiervon ist die Funktion formexeCommand der Datei /goform/execCommand. Durch die Manipulation des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-27T23:00:06.978Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-258294 | Tenda FH1205 execCommand formexeCommand stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.258294" }, { "name": "VDB-258294 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.258294" }, { "name": "Submit #301487 | Tenda FH1205 V2.0.0.7(775) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.301487" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formexeCommand.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-27T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-27T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-27T15:21:03.000Z", "value": "VulDB entry last update" } ], "title": "Tenda FH1205 execCommand formexeCommand stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3008", "datePublished": "2024-03-27T23:00:06.978Z", "dateReserved": "2024-03-27T14:15:25.516Z", "dateUpdated": "2024-08-01T19:32:42.533Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-38934
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-15 20:09
Severity ?
EPSS score ?
Summary
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.706Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetDeviceName/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.0.7(775)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38934", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-15T20:08:24.537653Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-15T20:09:42.651Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetDeviceName/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38934", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-15T20:09:42.651Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-38940
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-11 14:17
Severity ?
EPSS score ?
Summary
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.678Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/tree/main/tenda/form_fast_setting_wifi_set" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.0.7(775)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38940", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-11T14:16:25.895234Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-11T14:17:51.430Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/tree/main/tenda/form_fast_setting_wifi_set" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38940", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-11T14:17:51.430Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-38936
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-15 20:05
Severity ?
EPSS score ?
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.689Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.0.7(775)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38936", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-15T20:02:03.283677Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-15T20:05:36.911Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38936", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-15T20:05:36.911Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-38933
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-17 13:51
Severity ?
EPSS score ?
Summary
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.649Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.0.7(775)" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38933", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-17T13:48:33.206945Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-17T13:51:46.931Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38933", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-17T13:51:46.931Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-3006
Vulnerability from cvelistv5
Published
2024-03-27 22:31
Modified
2024-08-21 13:43
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258292. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.258292 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.258292 | signature, permissions-required | |
https://vuldb.com/?submit.301485 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromRouteStatic.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:32:42.567Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-258292 | Tenda FH1205 fromRouteStatic fromSetRouteStatic stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.258292" }, { "name": "VDB-258292 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.258292" }, { "name": "Submit #301485 | Tenda FH1205 V2.0.0.7(775) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.301485" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromRouteStatic.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1205_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.0.7\\/775\\/" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3006", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-21T13:41:30.577434Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-21T13:43:54.545Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "FH1205", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.0.7(775)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_mie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258292. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda FH1205 2.0.0.7(775) wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion fromSetRouteStatic der Datei /goform/fromRouteStatic. Dank Manipulation des Arguments entrys mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-27T22:31:05.391Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-258292 | Tenda FH1205 fromRouteStatic fromSetRouteStatic stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.258292" }, { "name": "VDB-258292 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.258292" }, { "name": "Submit #301485 | Tenda FH1205 V2.0.0.7(775) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.301485" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromRouteStatic.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-27T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-27T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-27T15:21:00.000Z", "value": "VulDB entry last update" } ], "title": "Tenda FH1205 fromRouteStatic fromSetRouteStatic stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3006", "datePublished": "2024-03-27T22:31:05.391Z", "dateReserved": "2024-03-27T14:15:18.455Z", "dateUpdated": "2024-08-21T13:43:54.545Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-38930
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-15 19:35
Severity ?
EPSS score ?
Summary
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.646Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0,V15.03.06.44" }, { "status": "affected", "version": "F1203 V2.0.1.6," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0,V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0,V15.03.06.42_multi" }, { "status": "affected", "version": "FH1205 V2.0.0.7(775)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38930", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-15T19:31:04.398117Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-15T19:35:44.164Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38930", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-15T19:35:44.164Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-3011
Vulnerability from cvelistv5
Published
2024-03-28 00:00
Modified
2024-08-01 19:32
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS score ?
Summary
A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.258297 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.258297 | signature, permissions-required | |
https://vuldb.com/?submit.301490 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formQuickIndex.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.0.7\\(775\\)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3011", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-16T21:01:27.896334Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-16T21:01:55.871Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:32:42.583Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-258297 | Tenda FH1205 QuickIndex formQuickIndex stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.258297" }, { "name": "VDB-258297 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.258297" }, { "name": "Submit #301490 | Tenda FH1205 V2.0.0.7(775) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.301490" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formQuickIndex.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "FH1205", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.0.7(775)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_mie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda FH1205 2.0.0.7(775) ausgemacht. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion formQuickIndex der Datei /goform/QuickIndex. Mittels Manipulieren des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-28T00:00:05.446Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-258297 | Tenda FH1205 QuickIndex formQuickIndex stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.258297" }, { "name": "VDB-258297 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.258297" }, { "name": "Submit #301490 | Tenda FH1205 V2.0.0.7(775) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.301490" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formQuickIndex.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-27T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-27T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-27T15:21:09.000Z", "value": "VulDB entry last update" } ], "title": "Tenda FH1205 QuickIndex formQuickIndex stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3011", "datePublished": "2024-03-28T00:00:05.446Z", "dateReserved": "2024-03-27T14:15:34.690Z", "dateUpdated": "2024-08-01T19:32:42.583Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2024-03-28 00:15
Modified
2025-01-15 18:24
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this issue is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258296. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formSetCfm.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.258296 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.258296 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.301489 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formSetCfm.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.258296 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.258296 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.301489 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this issue is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258296. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda FH1205 2.0.0.7(775) y clasificada como cr\u00edtica. La funci\u00f3n formSetCfm del archivo /goform/setcfm es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento funcpara1 provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-258296. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-3010", "lastModified": "2025-01-15T18:24:54.617", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-28T00:15:08.250", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formSetCfm.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258296" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258296" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301489" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formSetCfm.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258296" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258296" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301489" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-27 23:15
Modified
2025-01-15 18:22
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7(775). Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258294 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formexeCommand.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.258294 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.258294 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.301487 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formexeCommand.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.258294 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.258294 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.301487 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7(775). Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258294 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda FH1205 2.0.0.7(775) y clasificada como cr\u00edtica. La funci\u00f3n formexeCommand del fichero /goform/execCommand es afectada por la vulnerabilidad. La manipulaci\u00f3n del argumento cmdinput provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-258294 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-3008", "lastModified": "2025-01-15T18:22:18.167", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-27T23:15:47.340", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formexeCommand.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258294" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258294" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301487" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formexeCommand.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258294" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258294" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301487" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac10_firmware | 15.03.06.23 | |
tenda | ac10 | 1.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | fh1203_firmware | 2.0.1.6 | |
tenda | fh1203 | - | |
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function." } ], "id": "CVE-2023-38933", "lastModified": "2024-11-21T08:14:28.333", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:11.133", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md | Exploit, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md | Exploit, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac10_firmware | 15.03.06.23 | |
tenda | ac10 | 1.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | fh1203_firmware | 2.0.1.6 | |
tenda | fh1203 | - | |
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function." } ], "id": "CVE-2023-38936", "lastModified": "2024-11-21T08:14:28.797", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:11.343", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Vendor Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Vendor Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-28 00:15
Modified
2025-01-15 18:24
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formQuickIndex.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.258297 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.258297 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.301490 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formQuickIndex.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.258297 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.258297 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.301490 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda FH1205 2.0.0.7(775). Ha sido clasificada como cr\u00edtica. Esto afecta a la funci\u00f3n formQuickIndex del archivo /goform/QuickIndex. La manipulaci\u00f3n del argumento PPPOEPassword provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible iniciar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-258297. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-3011", "lastModified": "2025-01-15T18:24:46.023", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-28T00:15:08.500", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formQuickIndex.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258297" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258297" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301490" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formQuickIndex.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258297" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258297" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301490" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-28 00:15
Modified
2025-01-15 18:25
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been declared as critical. This vulnerability affects the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258298 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/GetParentControlInfo.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.258298 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.258298 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.301491 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/GetParentControlInfo.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.258298 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.258298 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.301491 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been declared as critical. This vulnerability affects the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258298 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda FH1205 2.0.0.7(775). Ha sido declarada cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n GetParentControlInfo del archivo /goform/GetParentControlInfo. La manipulaci\u00f3n del argumento mac conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-258298 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-3012", "lastModified": "2025-01-15T18:25:03.303", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-28T00:15:08.773", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/GetParentControlInfo.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258298" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258298" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301491" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/GetParentControlInfo.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258298" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258298" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301491" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/tree/main/tenda/form_fast_setting_wifi_set | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/tree/main/tenda/form_fast_setting_wifi_set | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1203_firmware | 2.0.1.6 | |
tenda | fh1203 | - | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function." } ], "id": "CVE-2023-38940", "lastModified": "2024-11-21T08:14:29.410", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:11.610", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/tree/main/tenda/form_fast_setting_wifi_set" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/tree/main/tenda/form_fast_setting_wifi_set" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-27 23:15
Modified
2025-01-15 18:21
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258292. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromRouteStatic.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.258292 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.258292 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.301485 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromRouteStatic.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.258292 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.258292 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.301485 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258292. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda FH1205 2.0.0.7(775) y clasificada como cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n fromSetRouteStatic del archivo /goform/fromRouteStatic. La manipulaci\u00f3n de las entradas de argumentos provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-258292. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-3006", "lastModified": "2025-01-15T18:21:47.937", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-27T23:15:46.880", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromRouteStatic.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258292" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258292" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301485" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromRouteStatic.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258292" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258292" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301485" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-28 00:15
Modified
2025-01-15 18:24
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability has been found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258295. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formWriteFacMac.md | Exploit | |
cna@vuldb.com | https://vuldb.com/?ctiid.258295 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.258295 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.301488 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formWriteFacMac.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.258295 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.258295 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.301488 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258295. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad ha sido encontrada en Tenda FH1205 2.0.0.7(775) y clasificada como cr\u00edtica. La funci\u00f3n formWriteFacMac del archivo /goform/WriteFacMac es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento mac conduce a la inyecci\u00f3n de comandos. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-258295. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-3009", "lastModified": "2025-01-15T18:24:35.790", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.4, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-28T00:15:07.993", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formWriteFacMac.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258295" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258295" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301488" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formWriteFacMac.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258295" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258295" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301488" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "cna@vuldb.com", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetDeviceName/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetDeviceName/README.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1203_firmware | 2.0.1.6 | |
tenda | fh1203 | - | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function." } ], "id": "CVE-2023-38934", "lastModified": "2024-11-21T08:14:28.497", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:11.207", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetDeviceName/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetDeviceName/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-27 23:15
Modified
2025-01-15 18:22
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7(775). This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258293 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromNatStaticSetting.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.258293 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.258293 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.301486 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromNatStaticSetting.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.258293 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.258293 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.301486 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7(775). This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258293 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda FH1205 2.0.0.7(775) y clasificada como cr\u00edtica. Este problema afecta la funci\u00f3n fromNatStaticSetting del archivo /goform/NatStaticSetting. La manipulaci\u00f3n de la p\u00e1gina de argumentos provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-258293. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-3007", "lastModified": "2025-01-15T18:22:05.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-27T23:15:47.110", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromNatStaticSetting.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258293" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258293" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301486" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/fromNatStaticSetting.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.258293" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.258293" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.301486" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function." } ], "id": "CVE-2023-38930", "lastModified": "2024-11-21T08:14:27.803", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:10.907", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }