Refine your search

4 vulnerabilities found for fh1201 by tenda

CVE-2025-14995 (GCVE-0-2025-14995)
Vulnerability from nvd
Published
2025-12-21 08:32
Modified
2025-12-22 16:19
CWE
Summary
A vulnerability has been found in Tenda FH1201 1.2.0.14(408). Affected is the function sprintf of the file /goform/SetIpBind. Such manipulation of the argument page leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
Tenda FH1201 Version: 1.2.0.14(408)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-14995",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-22T16:19:00.512969Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-22T16:19:07.359Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "FH1201",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.14(408)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "z472421519 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda FH1201 1.2.0.14(408). Affected is the function sprintf of the file /goform/SetIpBind. Such manipulation of the argument page leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-21T08:32:07.268Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-337689 | Tenda FH1201 SetIpBind sprintf stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.337689"
        },
        {
          "name": "VDB-337689 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.337689"
        },
        {
          "name": "Submit #719154 | Tenda FH1201 V1.2.0.14(408) Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.719154"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/z472421519/BinaryAudit/blob/main/PoC/BOF/Tenda_FH1201/SetIpBind/SetIpBind.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/z472421519/BinaryAudit/blob/main/PoC/BOF/Tenda_FH1201/SetIpBind/SetIpBind.md#reproduce"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-12-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-12-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-12-20T13:27:28.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda FH1201 SetIpBind sprintf stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-14995",
    "datePublished": "2025-12-21T08:32:07.268Z",
    "dateReserved": "2025-12-20T12:22:21.229Z",
    "dateUpdated": "2025-12-22T16:19:07.359Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-14994 (GCVE-0-2025-14994)
Vulnerability from nvd
Published
2025-12-21 07:32
Modified
2025-12-22 16:36
CWE
Summary
A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.
Impacted products
Vendor Product Version
Tenda FH1201 Version: 1.2.0.8(8155)
Version: 1.2.0.14(408)
Create a notification for this product.
   Tenda FH1206 Version: 1.2.0.8(8155)
Version: 1.2.0.14(408)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-14994",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-22T16:36:14.706437Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-22T16:36:21.363Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP Request Handler"
          ],
          "product": "FH1201",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.8(8155)"
            },
            {
              "status": "affected",
              "version": "1.2.0.14(408)"
            }
          ]
        },
        {
          "modules": [
            "HTTP Request Handler"
          ],
          "product": "FH1206",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.8(8155)"
            },
            {
              "status": "affected",
              "version": "1.2.0.14(408)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "z472421519 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-21T07:32:08.767Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-337688 | Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.337688"
        },
        {
          "name": "VDB-337688 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.337688"
        },
        {
          "name": "Submit #719153 | Tenda FH1201 V1.2.0.14(408) Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.719153"
        },
        {
          "name": "Submit #719155 | Tenda FH1206 1.2.0.8(8155) Stack-based Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.719155"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/z472421519/BinaryAudit/blob/main/PoC/BOF/Tenda_FH1201/webtyplibrary/webtypelibrary.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/z472421519/BinaryAudit/blob/main/PoC/BOF/Tenda_FH1206/webtyplibrary/webtypelibrary.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-12-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-12-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-12-20T13:31:24.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-14994",
    "datePublished": "2025-12-21T07:32:08.767Z",
    "dateReserved": "2025-12-20T12:22:17.860Z",
    "dateUpdated": "2025-12-22T16:36:21.363Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-14995 (GCVE-0-2025-14995)
Vulnerability from cvelistv5
Published
2025-12-21 08:32
Modified
2025-12-22 16:19
CWE
Summary
A vulnerability has been found in Tenda FH1201 1.2.0.14(408). Affected is the function sprintf of the file /goform/SetIpBind. Such manipulation of the argument page leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
Tenda FH1201 Version: 1.2.0.14(408)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-14995",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-22T16:19:00.512969Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-22T16:19:07.359Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "FH1201",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.14(408)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "z472421519 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda FH1201 1.2.0.14(408). Affected is the function sprintf of the file /goform/SetIpBind. Such manipulation of the argument page leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-21T08:32:07.268Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-337689 | Tenda FH1201 SetIpBind sprintf stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.337689"
        },
        {
          "name": "VDB-337689 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.337689"
        },
        {
          "name": "Submit #719154 | Tenda FH1201 V1.2.0.14(408) Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.719154"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/z472421519/BinaryAudit/blob/main/PoC/BOF/Tenda_FH1201/SetIpBind/SetIpBind.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/z472421519/BinaryAudit/blob/main/PoC/BOF/Tenda_FH1201/SetIpBind/SetIpBind.md#reproduce"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-12-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-12-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-12-20T13:27:28.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda FH1201 SetIpBind sprintf stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-14995",
    "datePublished": "2025-12-21T08:32:07.268Z",
    "dateReserved": "2025-12-20T12:22:21.229Z",
    "dateUpdated": "2025-12-22T16:19:07.359Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-14994 (GCVE-0-2025-14994)
Vulnerability from cvelistv5
Published
2025-12-21 07:32
Modified
2025-12-22 16:36
CWE
Summary
A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.
Impacted products
Vendor Product Version
Tenda FH1201 Version: 1.2.0.8(8155)
Version: 1.2.0.14(408)
Create a notification for this product.
   Tenda FH1206 Version: 1.2.0.8(8155)
Version: 1.2.0.14(408)
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-14994",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-22T16:36:14.706437Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-22T16:36:21.363Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP Request Handler"
          ],
          "product": "FH1201",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.8(8155)"
            },
            {
              "status": "affected",
              "version": "1.2.0.14(408)"
            }
          ]
        },
        {
          "modules": [
            "HTTP Request Handler"
          ],
          "product": "FH1206",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.8(8155)"
            },
            {
              "status": "affected",
              "version": "1.2.0.14(408)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "z472421519 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-21T07:32:08.767Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-337688 | Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.337688"
        },
        {
          "name": "VDB-337688 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.337688"
        },
        {
          "name": "Submit #719153 | Tenda FH1201 V1.2.0.14(408) Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.719153"
        },
        {
          "name": "Submit #719155 | Tenda FH1206 1.2.0.8(8155) Stack-based Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.719155"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/z472421519/BinaryAudit/blob/main/PoC/BOF/Tenda_FH1201/webtyplibrary/webtypelibrary.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/z472421519/BinaryAudit/blob/main/PoC/BOF/Tenda_FH1206/webtyplibrary/webtypelibrary.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-12-20T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-12-20T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-12-20T13:31:24.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-14994",
    "datePublished": "2025-12-21T07:32:08.767Z",
    "dateReserved": "2025-12-20T12:22:17.860Z",
    "dateUpdated": "2025-12-22T16:36:21.363Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}