Vulnerabilites related to broadcom - brocade_sannav
Vulnerability from fkie_nvd
Published
2024-04-19 05:15
Modified
2025-02-04 15:43
Summary
In Brocade SANnav before Brocade SANnav v2.31 and v2.3.0a, it was observed that Docker instances inside the appliance have insecure mount points, allowing reading and writing access to sensitive files. The vulnerability could allow a sudo privileged user on the host OS to read and write access to these files.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Brocade SANnav before Brocade SANnav v2.31 and v2.3.0a, it was observed that Docker instances inside the appliance have insecure mount points, allowing reading and writing access to sensitive files. The vulnerability could allow a sudo privileged user on the host OS to read and write access to these files. \n\n"
    },
    {
      "lang": "es",
      "value": "En Brocade SANnav anterior a Brocade SANnav v2.31 y v2.3.0a, se observ\u00f3 que las instancias de Docker dentro del dispositivo ten\u00edan puntos de montaje inseguros, lo que permit\u00eda acceso de lectura y escritura a archivos confidenciales. La vulnerabilidad podr\u00eda permitir que un usuario con privilegios sudo en el sistema operativo host tenga acceso de lectura y escritura a estos archivos."
    }
  ],
  "id": "CVE-2024-29967",
  "lastModified": "2025-02-04T15:43:15.313",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 4.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 6.0,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-19T05:15:49.737",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23254"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23254"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-276"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-276"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-11-08 18:15
Modified
2024-11-21 04:30
Summary
Password-based encryption (PBE) algorithm, of Brocade SANnav versions before v2.0, has a weakness in generating cryptographic keys that may allow an attacker to decrypt passwords used with several services (Radius, TACAS, etc.).
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CDB21EC-9E2B-4054-881F-63A89B247BF7",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Password-based encryption (PBE) algorithm, of Brocade SANnav versions before v2.0, has a weakness in generating cryptographic keys that may allow an attacker to decrypt passwords used with several services (Radius, TACAS, etc.)."
    },
    {
      "lang": "es",
      "value": "El algoritmo password-based encryption (PBE), de Brocade SANnav versiones anteriores a v2.0, presenta una debilidad en la generaci\u00f3n de claves criptogr\u00e1ficas que puede permitir a un atacante descifrar las contrase\u00f1as utilizadas con varios servicios (Radius, TACAS, etc.)."
    }
  ],
  "id": "CVE-2019-16208",
  "lastModified": "2024-11-21T04:30:16.563",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-11-08T18:15:12.747",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-867"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-867"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-327"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-17 19:15
Modified
2025-02-04 15:40
Summary
The class FileTransfer implemented in Brocade SANnav before v2.3.1, v2.3.0a, uses the ssh-rsa signature scheme, which has a SHA-1 hash. The vulnerability could allow a remote, unauthenticated attacker to perform a man-in-the-middle attack.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The class FileTransfer implemented in Brocade SANnav before v2.3.1, v2.3.0a, uses the ssh-rsa signature scheme, which has a SHA-1 hash.\nThe vulnerability could allow a remote, unauthenticated attacker to perform a man-in-the-middle attack.\n"
    },
    {
      "lang": "es",
      "value": "La clase FileTransfer implementada en Brocade SANnav antes de v2.3.1, v2.3.0a, utiliza el esquema de firma ssh-rsa, que tiene un hash SHA-1. La vulnerabilidad podr\u00eda permitir que un atacante remoto y no autenticado realice un ataque de intermediario."
    }
  ],
  "id": "CVE-2024-29950",
  "lastModified": "2025-02-04T15:40:21.197",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-17T19:15:07.213",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23236"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23236"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-326"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-326"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-06-09 16:15
Modified
2024-11-21 05:05
Summary
The host SSH servers of Brocade Fabric OS before Brocade Fabric OS v7.4.2h, v8.2.1c, v8.2.2, v9.0.0, and Brocade SANnav before v2.1.1 utilize keys of less than 2048 bits, which may be vulnerable to man-in-the-middle attacks and/or insecure SSH communications.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F078016A-D256-4A68-9C65-DF23B6858158",
              "versionEndExcluding": "2.1.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "31DFB192-EA22-4604-85ED-0A34E0DBF384",
              "versionEndExcluding": "7.4.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD800AD8-1792-4D0B-BE9C-FDCE1BF6BE31",
              "versionEndExcluding": "8.2.1",
              "versionStartIncluding": "8.2.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:broadcom:fabric_operating_system:7.4.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FEAE07D-906E-4B7C-B577-14D15CFFB69C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:broadcom:fabric_operating_system:7.4.2a:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A589310-66AB-4D4F-A332-64E245AB1D0B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:broadcom:fabric_operating_system:7.4.2b:*:*:*:*:*:*:*",
              "matchCriteriaId": "F633FD3F-8224-4D96-BD0C-55EA218D4364",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:broadcom:fabric_operating_system:7.4.2c:*:*:*:*:*:*:*",
              "matchCriteriaId": "656001D2-F17B-49C0-9F38-E84B5CE3E088",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:broadcom:fabric_operating_system:7.4.2d:*:*:*:*:*:*:*",
              "matchCriteriaId": "9761DF12-141D-4109-805D-449B5495ACB3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:broadcom:fabric_operating_system:7.4.2f:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD207CDF-7BF9-4FBD-86C4-C24B66D219FF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:broadcom:fabric_operating_system:7.4.2g:*:*:*:*:*:*:*",
              "matchCriteriaId": "518C9470-B56D-4B6C-99F9-20DEB3F86BBA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:broadcom:fabric_operating_system:8.2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C91FB6C-7BF5-453E-A618-06756D3DD2FB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:broadcom:fabric_operating_system:8.2.1a:*:*:*:*:*:*:*",
              "matchCriteriaId": "7CF38E78-8243-4615-A8A1-1396920F5BA1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:broadcom:fabric_operating_system:8.2.1b:*:*:*:*:*:*:*",
              "matchCriteriaId": "84E4F075-D03B-4D98-8C9E-840D80DFFF48",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The host SSH servers of Brocade Fabric OS before Brocade Fabric OS v7.4.2h, v8.2.1c, v8.2.2, v9.0.0, and Brocade SANnav before v2.1.1 utilize keys of less than 2048 bits, which may be vulnerable to man-in-the-middle attacks and/or insecure SSH communications."
    },
    {
      "lang": "es",
      "value": "Los servidores SSH del host de Brocade Fabric OS versiones anteriores a  v7.4.2h, v8.2.1c, v8.2.2, v9.0.0, y Brocade SANnav versiones anteriores a v2.1.1, utilizan claves de menos de 2048 bits, que pueden ser vulnerables a ataques de tipo man-in-the-middle y/o a comunicaciones SSH no seguras"
    }
  ],
  "id": "CVE-2020-15387",
  "lastModified": "2024-11-21T05:05:27.830",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.4,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-06-09T16:15:08.307",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1291"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1291"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-326"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-17 22:15
Modified
2025-02-04 16:02
Summary
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a could allow an authenticated user to print the Auth, Priv, and SSL key store passwords in unencrypted logs by manipulating command variables.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a could allow an authenticated user to print the Auth, Priv, and SSL key store passwords in unencrypted logs by manipulating command variables.\n\n"
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en Brocade SANnav anterior a v2.3.1 y v2.3.0a podr\u00eda permitir que un usuario autenticado imprima las contrase\u00f1as del almac\u00e9n de claves Auth, Priv y SSL en registros no cifrados manipulando variables de comando."
    }
  ],
  "id": "CVE-2024-29952",
  "lastModified": "2025-02-04T16:02:13.487",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-17T22:15:08.080",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23238"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23238"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-19 04:15
Modified
2025-02-04 15:52
Summary
A vulnerability affects Brocade SANnav before v2.3.1 and v2.3.0a. It allows a Brocade SANnav service to send ping commands in the background at regular intervals to gridgain.com to check if updates are available for the Component. This could make an unauthenticated, remote attacker aware of the behavior and launch a supply-chain attack against a Brocade SANnav appliance.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability affects Brocade SANnav before v2.3.1 and v2.3.0a. It allows a Brocade SANnav service to send ping commands in the background at regular intervals to gridgain.com to check if updates are available for the Component. This could make an unauthenticated, remote attacker aware of the behavior and launch a supply-chain attack against a Brocade SANnav appliance.\n"
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad afecta a Brocade SANnav anterior a v2.3.1 y v2.3.0a. Permite que un servicio Brocade SANnav env\u00ede comandos de ping en segundo plano a intervalos regulares a gridgain.com para verificar si hay actualizaciones disponibles para el Componente. Esto podr\u00eda hacer que un atacante remoto no autenticado se d\u00e9 cuenta del comportamiento y lance un ataque a la cadena de suministro contra un dispositivo Brocade SANnav."
    }
  ],
  "id": "CVE-2024-29961",
  "lastModified": "2025-02-04T15:52:04.420",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.2,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-19T04:15:10.553",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23246"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23246"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-01-18 16:15
Modified
2024-11-21 06:48
Summary
JMSSink in all versions of Log4j 1.x is vulnerable to deserialization of untrusted data when the attacker has write access to the Log4j configuration or if the configuration references an LDAP service the attacker has access to. The attacker can provide a TopicConnectionFactoryBindingName configuration causing JMSSink to perform JNDI requests that result in remote code execution in a similar fashion to CVE-2021-4104. Note this issue only affects Log4j 1.x when specifically configured to use JMSSink, which is not the default. Apache Log4j 1.2 reached end of life in August 2015. Users should upgrade to Log4j 2 as it addresses numerous other issues from the previous versions.
Impacted products
Vendor Product Version
apache log4j *
netapp snapmanager -
netapp snapmanager -
broadcom brocade_sannav -
qos reload4j *
oracle advanced_supply_chain_planning 12.1
oracle advanced_supply_chain_planning 12.2
oracle business_intelligence 5.9.0.0.0
oracle business_intelligence 12.2.1.3.0
oracle business_intelligence 12.2.1.4.0
oracle business_process_management_suite 12.2.1.3.0
oracle business_process_management_suite 12.2.1.4.0
oracle communications_eagle_ftp_table_base_retrieval 4.5
oracle communications_instant_messaging_server 10.0.1.5.0
oracle communications_messaging_server 8.1
oracle communications_network_integrity 7.3.6
oracle communications_offline_mediation_controller *
oracle communications_offline_mediation_controller 12.0.0.5.0
oracle communications_unified_inventory_management 7.4.1
oracle communications_unified_inventory_management 7.4.2
oracle e-business_suite_cloud_manager_and_cloud_backup_module *
oracle e-business_suite_cloud_manager_and_cloud_backup_module 2.2.1.1.1
oracle enterprise_manager_base_platform 13.4.0.0
oracle enterprise_manager_base_platform 13.5.0.0
oracle financial_services_revenue_management_and_billing_analytics 2.7.0.0
oracle financial_services_revenue_management_and_billing_analytics 2.7.0.1
oracle financial_services_revenue_management_and_billing_analytics 2.8.0.0
oracle healthcare_foundation 8.1.0
oracle hyperion_data_relationship_management *
oracle hyperion_infrastructure_technology *
oracle identity_management_suite 12.2.1.3.0
oracle identity_management_suite 12.2.1.4.0
oracle identity_manager_connector 11.1.1.5.0
oracle jdeveloper 12.2.1.3.0
oracle middleware_common_libraries_and_tools 12.2.1.4.0
oracle mysql_enterprise_monitor *
oracle tuxedo 12.2.2.0.0
oracle weblogic_server 12.2.1.3.0
oracle weblogic_server 12.2.1.4.0
oracle weblogic_server 14.1.1.0.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:apache:log4j:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A81678B-BD7A-42A5-84FF-DC2D3D650650",
              "versionEndIncluding": "1.2.17",
              "versionStartIncluding": "1.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:netapp:snapmanager:-:*:*:*:*:oracle:*:*",
              "matchCriteriaId": "26A2B713-7D6D-420A-93A4-E0D983C983DF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:snapmanager:-:*:*:*:*:sap:*:*",
              "matchCriteriaId": "64DE38C8-94F1-4860-B045-F33928F676A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75B1EDA5-F189-440D-AD0E-C70DD2C0FEE5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:qos:reload4j:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB681829-2B2A-4BDB-8DC5-B3C7D359F4C5",
              "versionEndExcluding": "1.2.18.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:oracle:advanced_supply_chain_planning:12.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "A62E2A25-1AD7-4B4B-9D1B-F0DEA4550557",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:advanced_supply_chain_planning:12.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "0331158C-BBE0-42DB-8180-EB1FCD290567",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:business_intelligence:5.9.0.0.0:*:*:*:enterprise:*:*:*",
              "matchCriteriaId": "B602F9E8-1580-436C-A26D-6E6F8121A583",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:business_intelligence:12.2.1.3.0:*:*:*:enterprise:*:*:*",
              "matchCriteriaId": "77C3DD16-1D81-40E1-B312-50FBD275507C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:business_intelligence:12.2.1.4.0:*:*:*:enterprise:*:*:*",
              "matchCriteriaId": "81DAC8C0-D342-44B5-9432-6B88D389584F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:business_process_management_suite:12.2.1.3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E869C417-C0E6-4FC3-B406-45598A1D1906",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:business_process_management_suite:12.2.1.4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFEFE2C0-7B98-44F9-B3AD-D6EC607E90DA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_eagle_ftp_table_base_retrieval:4.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "C68536CA-C7E2-4228-A6B8-F0DB6A9D29EC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_instant_messaging_server:10.0.1.5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4A94B36-479F-48F2-9B9E-ACEA2589EF48",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_messaging_server:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1214FDF-357A-4BB9-BADE-50FB2BD16D10",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_network_integrity:7.3.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "B21E6EEF-2AB7-4E96-B092-1F49D11B4175",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_offline_mediation_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A2E42A-4EF2-437D-A0EC-4A6A4F1EBD11",
              "versionEndExcluding": "12.0.0.4.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_offline_mediation_controller:12.0.0.5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "5933FEA2-B79E-4EE7-B821-54D676B45734",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_unified_inventory_management:7.4.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7637F8B-15F1-42E2-BE18-E1FF7C66587D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_unified_inventory_management:7.4.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "E43D793A-7756-4D58-A8ED-72DC4EC9CEA7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:e-business_suite_cloud_manager_and_cloud_backup_module:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86EF205C-9CB1-4772-94D1-0B744EF3342D",
              "versionEndExcluding": "2.2.1.1.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:e-business_suite_cloud_manager_and_cloud_backup_module:2.2.1.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "6ED0EE39-C080-4E75-AE0F-3859B57EF851",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:enterprise_manager_base_platform:13.4.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D26F3E23-F1A9-45E7-9E5F-0C0A24EE3783",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:enterprise_manager_base_platform:13.5.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E8758C8-87D3-450A-878B-86CE8C9FC140",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:financial_services_revenue_management_and_billing_analytics:2.7.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "054B56E0-F11B-4939-B7E1-E722C67A041A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:financial_services_revenue_management_and_billing_analytics:2.7.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "250A493C-E052-4978-ABBE-786DC8038448",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:financial_services_revenue_management_and_billing_analytics:2.8.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E2B771B-230A-4811-94D7-065C2722E428",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:healthcare_foundation:8.1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E67501BE-206A-49FD-8CBA-22935DF917F1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:hyperion_data_relationship_management:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8E7FBA9-0FFF-4C86-B151-28C17A142E0B",
              "versionEndExcluding": "11.2.8.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:hyperion_infrastructure_technology:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "55BBCD48-BCC6-4E19-A4CE-970E524B9FF4",
              "versionEndExcluding": "11.2.8.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:identity_management_suite:12.2.1.3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "1489DDA7-EDBE-404C-B48D-F0B52B741708",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:identity_management_suite:12.2.1.4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "535BC19C-21A1-48E3-8CC0-B276BA5D494E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:identity_manager_connector:11.1.1.5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7EA92D-9F26-4292-991A-891597337DFD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:jdeveloper:12.2.1.3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "228DA523-4D6D-48C5-BDB0-DB1A60F23F8B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:middleware_common_libraries_and_tools:12.2.1.4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AB179A8-DFB7-4DCF-8DE3-096F376989F1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:mysql_enterprise_monitor:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0EBAC6D-D0CE-42A1-AEA0-2D50C8035747",
              "versionEndIncluding": "8.0.29",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:tuxedo:12.2.2.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7D0A30-3986-49AB-B7F3-DAE0024504BA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:weblogic_server:12.2.1.3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "F14A818F-AA16-4438-A3E4-E64C9287AC66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:weblogic_server:12.2.1.4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A5BB153-68E0-4DDA-87D1-0D9AB7F0A418",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:weblogic_server:14.1.1.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "04BCDC24-4A21-473C-8733-0D9CFB38A752",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "JMSSink in all versions of Log4j 1.x is vulnerable to deserialization of untrusted data when the attacker has write access to the Log4j configuration or if the configuration references an LDAP service the attacker has access to. The attacker can provide a TopicConnectionFactoryBindingName configuration causing JMSSink to perform JNDI requests that result in remote code execution in a similar fashion to CVE-2021-4104. Note this issue only affects Log4j 1.x when specifically configured to use JMSSink, which is not the default. Apache Log4j 1.2 reached end of life in August 2015. Users should upgrade to Log4j 2 as it addresses numerous other issues from the previous versions."
    },
    {
      "lang": "es",
      "value": "JMSSink en todas las versiones de Log4j 1.x, es vulnerable a una deserializaci\u00f3n de datos no confiables cuando el atacante presenta acceso de escritura a la configuraci\u00f3n de Log4j o si la configuraci\u00f3n hace referencia a un servicio LDAP al que el atacante presenta acceso. El atacante puede proporcionar una configuraci\u00f3n TopicConnectionFactoryBindingName causando que JMSSink lleve a cabo peticiones JNDI que resulten en la ejecuci\u00f3n de c\u00f3digo remota de forma similar a CVE-2021-4104. Tenga en cuenta que este problema s\u00f3lo afecta a Log4j versiones 1.x cuando es configurado espec\u00edficamente para usar JMSSink, que no es el predeterminado. Apache Log4j versi\u00f3n 1.2 lleg\u00f3 al final de su vida \u00fatil en agosto de 2015. Los usuarios deber\u00edan actualizar a Log4j 2 ya que aborda otros numerosos problemas de las versiones anteriores"
    }
  ],
  "id": "CVE-2022-23302",
  "lastModified": "2024-11-21T06:48:21.983",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-01-18T16:15:08.300",
  "references": [
    {
      "source": "security@apache.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2022/01/18/3"
    },
    {
      "source": "security@apache.org",
      "tags": [
        "Mailing List",
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://lists.apache.org/thread/bsr3l5qz4g0myrjhy9h67bcxodpkwj4w"
    },
    {
      "source": "security@apache.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://logging.apache.org/log4j/1.2/index.html"
    },
    {
      "source": "security@apache.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20220217-0006/"
    },
    {
      "source": "security@apache.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
    },
    {
      "source": "security@apache.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2022/01/18/3"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://lists.apache.org/thread/bsr3l5qz4g0myrjhy9h67bcxodpkwj4w"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://logging.apache.org/log4j/1.2/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20220217-0006/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
    }
  ],
  "sourceIdentifier": "security@apache.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-502"
        }
      ],
      "source": "security@apache.org",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-502"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-11-21 11:15
Modified
2025-02-04 18:14
Summary
Brocade SANnav before Brocade SANnav 2.2.2 supports key exchange algorithms, which are considered weak on ports 24, 6514, 18023, 19094, and 19095.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC77C573-F6AD-451A-B543-682C9276861D",
              "versionEndExcluding": "2.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade SANnav before Brocade SANnav 2.2.2 supports key exchange algorithms, which are considered weak on ports 24, 6514, 18023, 19094, and 19095."
    },
    {
      "lang": "es",
      "value": "Brocade SANnav anterior a Brocade SANnav 2.2.2 admite algoritmos de intercambio de claves, que se consideran d\u00e9biles en los puertos 24, 6514, 18023, 19094 y 19095."
    }
  ],
  "id": "CVE-2022-43934",
  "lastModified": "2025-02-04T18:14:21.470",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-11-21T11:15:12.840",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/21220"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-327"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-327"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-11-21 11:15
Modified
2025-02-04 18:16
Summary
An information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where Brocade Fabric OS Switch passwords and authorization IDs are printed in the embedded MLS DB file.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC77C573-F6AD-451A-B543-682C9276861D",
              "versionEndExcluding": "2.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where Brocade Fabric OS Switch passwords and authorization IDs are printed in the embedded MLS DB file."
    },
    {
      "lang": "es",
      "value": "Existe una exposici\u00f3n de informaci\u00f3n a trav\u00e9s de una vulnerabilidad de archivo de registro en Brocade SANnav anterior a Brocade SANnav 2.2.2, donde las contrase\u00f1as y las identificaciones de autorizaci\u00f3n de Brocade Fabric OS Switch se imprimen en el archivo MLS DB integrado."
    }
  ],
  "id": "CVE-2022-43935",
  "lastModified": "2025-02-04T18:16:02.403",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 4.0,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 4.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-11-21T11:15:14.363",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/21219"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-19 05:15
Modified
2025-02-04 15:45
Summary
In Brocade SANnav before v2.3.1, and v2.3.0a, it is possible to back up the appliance from the web interface or the command line interface ("SSH"). The resulting backups are world-readable. A local attacker can recover backup files, restore them to a new malicious appliance, and retrieve the passwords of all the switches.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nIn Brocade SANnav before v2.3.1, and v2.3.0a, it is possible to back up the appliance from the web interface or the command line interface (\"SSH\"). The resulting backups are world-readable. A local attacker can recover backup files, restore them to a new malicious appliance, and retrieve the passwords of all the switches.\n\n"
    },
    {
      "lang": "es",
      "value": "En Brocade SANnav anterior a v2.3.1 y v2.3.0a, es posible realizar una copia de seguridad del dispositivo desde la interfaz web o la interfaz de l\u00ednea de comandos (\"SSH\"). Las copias de seguridad resultantes son legibles en todo el mundo. Un atacante local puede recuperar archivos de respaldo, restaurarlos en un nuevo dispositivo malicioso y recuperar las contrase\u00f1as de todos los conmutadores."
    }
  ],
  "id": "CVE-2024-29965",
  "lastModified": "2025-02-04T15:45:17.783",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.3,
        "impactScore": 4.0,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.5,
        "impactScore": 4.0,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-19T05:15:49.390",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23250"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23250"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-922"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-922"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-11-21 11:15
Modified
2025-02-04 18:19
Summary
Brocade SANnav versions before 2.2.2 log Brocade Fabric OS switch passwords when debugging is enabled.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC77C573-F6AD-451A-B543-682C9276861D",
              "versionEndExcluding": "2.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade SANnav versions before 2.2.2 log Brocade Fabric OS switch passwords when debugging is enabled."
    },
    {
      "lang": "es",
      "value": "Las versiones de Brocade SANnav anteriores a 2.2.2 registran las contrase\u00f1as de cambio del sistema operativo Brocade Fabric cuando la depuraci\u00f3n est\u00e1 habilitada."
    }
  ],
  "id": "CVE-2022-43936",
  "lastModified": "2025-02-04T18:19:49.940",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.3,
        "impactScore": 4.0,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-11-21T11:15:14.540",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/21218"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-12-09 02:15
Modified
2024-11-21 07:07
Summary
Brocade SANnav before v2.2.1 logs usernames and encoded passwords in debug-enabled logs. The vulnerability could allow an attacker with admin privilege to read sensitive information.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47FCF79D-70A4-4335-9ACF-D5DA8B6DBE3D",
              "versionEndExcluding": "2.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade SANnav before v2.2.1 logs usernames and encoded passwords in \ndebug-enabled logs. The vulnerability could allow an attacker with admin\n privilege to read sensitive information.\n\n"
    },
    {
      "lang": "es",
      "value": "Brocade SANnav anterior a v2.2.1 registra nombres de usuarios y contrase\u00f1as codificadas en registros habilitados para depuraci\u00f3n. La vulnerabilidad podr\u00eda permitir que un atacante con privilegios de administrador lea informaci\u00f3n confidencial."
    }
  ],
  "id": "CVE-2022-33187",
  "lastModified": "2024-11-21T07:07:40.927",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 4.2,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-12-09T02:15:09.070",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2022-2122"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2022-2122"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-17 20:15
Modified
2025-02-04 16:01
Summary
Brocade SANnav before v2.3.1 and v2.3.0a uses the SHA-1 hash in internal SSH ports that are not open to remote connection.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade SANnav before v2.3.1 and v2.3.0a uses the SHA-1 hash in internal SSH ports that are not open to remote connection.\n\n"
    },
    {
      "lang": "es",
      "value": "Brocade SANnav anterior a v2.3.1 y v2.3.0a utiliza el hash SHA-1 en puertos SSH internos que no est\u00e1n abiertos a conexiones remotas."
    }
  ],
  "id": "CVE-2024-29951",
  "lastModified": "2025-02-04T16:01:19.393",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-17T20:15:08.060",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23237"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23237"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-326"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-326"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-11-08 18:15
Modified
2024-11-21 04:30
Summary
A vulnerability, in Brocade SANnav versions before v2.0, could allow remote attackers to brute-force a valid session ID. The vulnerability is due to an insufficiently random session ID for several post-authentication actions in the SANnav portal.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CDB21EC-9E2B-4054-881F-63A89B247BF7",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability, in Brocade SANnav versions before v2.0, could allow remote attackers to brute-force a valid session ID. The vulnerability is due to an insufficiently random session ID for several post-authentication actions in the SANnav portal."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad, en Brocade SANnav versiones anteriores a v2.0, podr\u00eda permitir a atacantes remotos forzar mediante fuerza bruta un ID de sesi\u00f3n v\u00e1lido. La vulnerabilidad es debido a un ID de sesi\u00f3n insuficientemente aleatorio para varias acciones posteriores a la autenticaci\u00f3n en el portal SANnav."
    }
  ],
  "id": "CVE-2019-16205",
  "lastModified": "2024-11-21T04:30:16.233",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-11-08T18:15:12.527",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-864"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-864"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-330"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-17 22:15
Modified
2025-02-04 16:03
Summary
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a could allow a privileged user to print the SANnav encrypted key in PostgreSQL startup logs. This could provide attackers with an additional, less-protected path to acquiring the encryption key.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a could allow a privileged user to print the SANnav encrypted key in PostgreSQL startup logs. \nThis could provide attackers with an additional, less-protected path to acquiring the encryption key. \n\n"
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en Brocade SANnav anterior a v2.3.1 y v2.3.0a podr\u00eda permitir a un usuario privilegiado imprimir la clave cifrada de SANnav en los registros de inicio de PostgreSQL. Esto podr\u00eda proporcionar a los atacantes una ruta adicional y menos protegida para adquirir la clave de cifrado."
    }
  ],
  "id": "CVE-2024-29955",
  "lastModified": "2025-02-04T16:03:04.923",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.3,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-17T22:15:08.370",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23239"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23239"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-19 05:15
Modified
2025-02-04 15:47
Summary
Brocade SANnav versions before v2.3.0a do not correctly set permissions on files, including docker files. An unprivileged attacker who gains access to the server can read sensitive information from these files.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade SANnav versions before v2.3.0a do not correctly set permissions on files, including docker files. An unprivileged attacker who gains access to the server can read sensitive information from these files."
    },
    {
      "lang": "es",
      "value": "Las instancias de Docker en Brocade SANnav anteriores a v2.3.1 y v2.3.0a tienen una arquitectura y configuraci\u00f3n inseguras que generan m\u00faltiples vulnerabilidades. Los demonios de Docker est\u00e1n expuestos a la interfaz WAN y otras vulnerabilidades permiten un control total sobre el dispositivo Ova. Una instancia de Docker podr\u00eda acceder a cualquier otra instancia y algunas podr\u00edan acceder a archivos confidenciales. La vulnerabilidad podr\u00eda permitir que un usuario con privilegios sudo en el sistema operativo subyacente acceda y modifique estos archivos."
    }
  ],
  "id": "CVE-2024-29964",
  "lastModified": "2025-02-04T15:47:25.243",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-19T05:15:49.217",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23249"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23249"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-19 04:15
Modified
2025-02-04 15:57
Summary
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints the encryption key in the console when a privileged user executes the script to replace the Brocade SANnav Management Portal standby node. This could provide attackers an additional, less protected path to acquiring the encryption key.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints the encryption key in the console when a privileged user executes the script to replace the Brocade SANnav Management Portal standby node. This could provide attackers an additional, less protected path to acquiring the encryption key.\n"
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en Brocade SANnav anterior a v2.3.1 y v2.3.0a imprime la clave de cifrado en la consola cuando un usuario privilegiado ejecuta el script para reemplazar el nodo en espera del Portal de administraci\u00f3n de Brocade SANnav. Esto podr\u00eda proporcionar a los atacantes una ruta adicional y menos protegida para adquirir la clave de cifrado."
    }
  ],
  "id": "CVE-2024-29958",
  "lastModified": "2025-02-04T15:57:10.910",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-19T04:15:09.653",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23242"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23242"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-19 05:15
Modified
2025-02-04 15:48
Summary
Brocade SANnav OVA before v2.3.1 and v2.3.0a have an insecure file permission setting that makes files world-readable. This could allow a local user without the required privileges to access sensitive information or a Java binary.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade SANnav OVA before v2.3.1 and v2.3.0a have an insecure file permission setting that makes files world-readable. This could allow a local user without the required privileges to access sensitive information or a Java binary.\n\n"
    },
    {
      "lang": "es",
      "value": "Brocade SANnav OVA anteriores a v2.3.1 y v2.3.0a tienen una configuraci\u00f3n de permisos de archivos inseguros que hace que los archivos sean legibles en todo el mundo. Esto podr\u00eda permitir que un usuario local sin los privilegios necesarios acceda a informaci\u00f3n confidencial o a un binario de Java."
    }
  ],
  "id": "CVE-2024-29962",
  "lastModified": "2025-02-04T15:48:07.963",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-19T05:15:48.940",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23248"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23248"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-276"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-276"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-19 04:15
Modified
2025-02-04 15:51
Summary
Brocade SANnav OVA before v2.3.1, and v2.3.0a, contain hardcoded TLS keys used by Docker. Note: Brocade SANnav doesn't have access to remote Docker registries.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nBrocade SANnav OVA before v2.3.1, and v2.3.0a, contain hardcoded TLS keys used by Docker. Note: Brocade SANnav doesn\u0027t have access to remote Docker registries.\n\n"
    },
    {
      "lang": "es",
      "value": "Brocade SANnav OVA anterior a v2.3.1 y v2.3.0a contiene claves codificadas utilizadas por Docker para acceder a registros remotos a trav\u00e9s de TLS. Las conexiones TLS con una clave expuesta permiten a un atacante MITM el tr\u00e1fico. Nota: Brocade SANnav no tiene acceso a registros Docker remotos."
    }
  ],
  "id": "CVE-2024-29963",
  "lastModified": "2025-02-04T15:51:01.833",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 1.9,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 0.5,
        "impactScore": 1.4,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 3.8,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.0,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-19T04:15:10.793",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23247"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23247"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-01-18 16:15
Modified
2024-11-21 06:48
Severity ?
Summary
By design, the JDBCAppender in Log4j 1.2.x accepts an SQL statement as a configuration parameter where the values to be inserted are converters from PatternLayout. The message converter, %m, is likely to always be included. This allows attackers to manipulate the SQL by entering crafted strings into input fields or headers of an application that are logged allowing unintended SQL queries to be executed. Note this issue only affects Log4j 1.x when specifically configured to use the JDBCAppender, which is not the default. Beginning in version 2.0-beta8, the JDBCAppender was re-introduced with proper support for parameterized SQL queries and further customization over the columns written to in logs. Apache Log4j 1.2 reached end of life in August 2015. Users should upgrade to Log4j 2 as it addresses numerous other issues from the previous versions.
Impacted products
Vendor Product Version
apache log4j *
netapp snapmanager -
netapp snapmanager -
broadcom brocade_sannav -
qos reload4j *
oracle advanced_supply_chain_planning 12.1
oracle advanced_supply_chain_planning 12.2
oracle business_intelligence 5.9.0.0.0
oracle business_intelligence 12.2.1.3.0
oracle business_intelligence 12.2.1.4.0
oracle business_process_management_suite 12.2.1.3.0
oracle business_process_management_suite 12.2.1.4.0
oracle communications_eagle_ftp_table_base_retrieval 4.5
oracle communications_instant_messaging_server 10.0.1.5.0
oracle communications_messaging_server 8.1
oracle communications_network_integrity 7.3.6
oracle communications_offline_mediation_controller *
oracle communications_offline_mediation_controller 12.0.0.5.0
oracle communications_unified_inventory_management 7.4.1
oracle communications_unified_inventory_management 7.4.2
oracle e-business_suite_cloud_manager_and_cloud_backup_module *
oracle e-business_suite_cloud_manager_and_cloud_backup_module 2.2.1.1.1
oracle e-business_suite_information_discovery *
oracle enterprise_manager_base_platform 13.4.0.0
oracle enterprise_manager_base_platform 13.5.0.0
oracle financial_services_revenue_management_and_billing_analytics 2.7.0.0
oracle financial_services_revenue_management_and_billing_analytics 2.7.0.1
oracle financial_services_revenue_management_and_billing_analytics 2.8.0.0
oracle healthcare_foundation 8.1.0
oracle hyperion_data_relationship_management *
oracle hyperion_infrastructure_technology *
oracle identity_management_suite 12.2.1.3.0
oracle identity_management_suite 12.2.1.4.0
oracle identity_manager_connector 11.1.1.5.0
oracle jdeveloper 12.2.1.3.0
oracle middleware_common_libraries_and_tools 12.2.1.4.0
oracle mysql_enterprise_monitor *
oracle retail_extract_transform_and_load 13.2.5
oracle tuxedo 12.2.2.0.0
oracle weblogic_server 12.2.1.3.0
oracle weblogic_server 12.2.1.4.0
oracle weblogic_server 14.1.1.0.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:apache:log4j:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C02831A-AD76-43D3-BEB1-DA94FA70A25E",
              "versionEndIncluding": "1.2.17",
              "versionStartIncluding": "1.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:netapp:snapmanager:-:*:*:*:*:oracle:*:*",
              "matchCriteriaId": "26A2B713-7D6D-420A-93A4-E0D983C983DF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:snapmanager:-:*:*:*:*:sap:*:*",
              "matchCriteriaId": "64DE38C8-94F1-4860-B045-F33928F676A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75B1EDA5-F189-440D-AD0E-C70DD2C0FEE5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:qos:reload4j:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDAF3CC9-3827-4634-85B6-DA94368067EB",
              "versionEndExcluding": "1.2.18.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:oracle:advanced_supply_chain_planning:12.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "A62E2A25-1AD7-4B4B-9D1B-F0DEA4550557",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:advanced_supply_chain_planning:12.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "0331158C-BBE0-42DB-8180-EB1FCD290567",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:business_intelligence:5.9.0.0.0:*:*:*:enterprise:*:*:*",
              "matchCriteriaId": "B602F9E8-1580-436C-A26D-6E6F8121A583",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:business_intelligence:12.2.1.3.0:*:*:*:enterprise:*:*:*",
              "matchCriteriaId": "77C3DD16-1D81-40E1-B312-50FBD275507C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:business_intelligence:12.2.1.4.0:*:*:*:enterprise:*:*:*",
              "matchCriteriaId": "81DAC8C0-D342-44B5-9432-6B88D389584F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:business_process_management_suite:12.2.1.3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E869C417-C0E6-4FC3-B406-45598A1D1906",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:business_process_management_suite:12.2.1.4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFEFE2C0-7B98-44F9-B3AD-D6EC607E90DA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_eagle_ftp_table_base_retrieval:4.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "C68536CA-C7E2-4228-A6B8-F0DB6A9D29EC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_instant_messaging_server:10.0.1.5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4A94B36-479F-48F2-9B9E-ACEA2589EF48",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_messaging_server:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1214FDF-357A-4BB9-BADE-50FB2BD16D10",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_network_integrity:7.3.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "B21E6EEF-2AB7-4E96-B092-1F49D11B4175",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_offline_mediation_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A2E42A-4EF2-437D-A0EC-4A6A4F1EBD11",
              "versionEndExcluding": "12.0.0.4.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_offline_mediation_controller:12.0.0.5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "5933FEA2-B79E-4EE7-B821-54D676B45734",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_unified_inventory_management:7.4.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7637F8B-15F1-42E2-BE18-E1FF7C66587D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:communications_unified_inventory_management:7.4.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "E43D793A-7756-4D58-A8ED-72DC4EC9CEA7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:e-business_suite_cloud_manager_and_cloud_backup_module:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86EF205C-9CB1-4772-94D1-0B744EF3342D",
              "versionEndExcluding": "2.2.1.1.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:e-business_suite_cloud_manager_and_cloud_backup_module:2.2.1.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "6ED0EE39-C080-4E75-AE0F-3859B57EF851",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:e-business_suite_information_discovery:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D63C2CE-622B-48A8-BD74-09A9B05EDE7C",
              "versionEndIncluding": "12.2.11",
              "versionStartIncluding": "12.2.3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:enterprise_manager_base_platform:13.4.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D26F3E23-F1A9-45E7-9E5F-0C0A24EE3783",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:enterprise_manager_base_platform:13.5.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E8758C8-87D3-450A-878B-86CE8C9FC140",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:financial_services_revenue_management_and_billing_analytics:2.7.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "054B56E0-F11B-4939-B7E1-E722C67A041A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:financial_services_revenue_management_and_billing_analytics:2.7.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "250A493C-E052-4978-ABBE-786DC8038448",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:financial_services_revenue_management_and_billing_analytics:2.8.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E2B771B-230A-4811-94D7-065C2722E428",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:healthcare_foundation:8.1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E67501BE-206A-49FD-8CBA-22935DF917F1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:hyperion_data_relationship_management:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8E7FBA9-0FFF-4C86-B151-28C17A142E0B",
              "versionEndExcluding": "11.2.8.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:hyperion_infrastructure_technology:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "55BBCD48-BCC6-4E19-A4CE-970E524B9FF4",
              "versionEndExcluding": "11.2.8.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:identity_management_suite:12.2.1.3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "1489DDA7-EDBE-404C-B48D-F0B52B741708",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:identity_management_suite:12.2.1.4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "535BC19C-21A1-48E3-8CC0-B276BA5D494E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:identity_manager_connector:11.1.1.5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7EA92D-9F26-4292-991A-891597337DFD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:jdeveloper:12.2.1.3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "228DA523-4D6D-48C5-BDB0-DB1A60F23F8B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:middleware_common_libraries_and_tools:12.2.1.4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AB179A8-DFB7-4DCF-8DE3-096F376989F1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:mysql_enterprise_monitor:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0EBAC6D-D0CE-42A1-AEA0-2D50C8035747",
              "versionEndIncluding": "8.0.29",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:retail_extract_transform_and_load:13.2.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "30501D23-5044-477A-8DC3-7610126AEFD7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:tuxedo:12.2.2.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7D0A30-3986-49AB-B7F3-DAE0024504BA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:weblogic_server:12.2.1.3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "F14A818F-AA16-4438-A3E4-E64C9287AC66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:weblogic_server:12.2.1.4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A5BB153-68E0-4DDA-87D1-0D9AB7F0A418",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:weblogic_server:14.1.1.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "04BCDC24-4A21-473C-8733-0D9CFB38A752",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "By design, the JDBCAppender in Log4j 1.2.x accepts an SQL statement as a configuration parameter where the values to be inserted are converters from PatternLayout. The message converter, %m, is likely to always be included. This allows attackers to manipulate the SQL by entering crafted strings into input fields or headers of an application that are logged allowing unintended SQL queries to be executed. Note this issue only affects Log4j 1.x when specifically configured to use the JDBCAppender, which is not the default. Beginning in version 2.0-beta8, the JDBCAppender was re-introduced with proper support for parameterized SQL queries and further customization over the columns written to in logs. Apache Log4j 1.2 reached end of life in August 2015. Users should upgrade to Log4j 2 as it addresses numerous other issues from the previous versions."
    },
    {
      "lang": "es",
      "value": "Por dise\u00f1o, el JDBCAppender en Log4j versiones 1.2.x, acepta una sentencia SQL como par\u00e1metro de configuraci\u00f3n donde los valores a insertar son convertidores de PatternLayout. Es probable que el convertidor de mensajes, %m, sea incluido siempre. Esto permite a atacantes manipular el SQL introduciendo cadenas dise\u00f1adas en los campos de entrada o en los encabezados de una aplicaci\u00f3n que son registradas permitiendo una ejecuci\u00f3n de consultas SQL no deseadas. Tenga en cuenta que este problema s\u00f3lo afecta a Log4j versiones 1.x cuando es configurado espec\u00edficamente para usar el JDBCAppender, que no es el predeterminado. A partir de la versi\u00f3n 2.0-beta8, fue reintroducido el JDBCAppender con soporte apropiado para consultas SQL parametrizadas y mayor personalizaci\u00f3n sobre las columnas escritas en los registros. Apache Log4j versiones 1.2 lleg\u00f3 al final de su vida \u00fatil en agosto de 2015. Los usuarios deber\u00edan actualizar a Log4j 2, ya que aborda numerosos problemas de las versiones anteriores"
    }
  ],
  "id": "CVE-2022-23305",
  "lastModified": "2024-11-21T06:48:22.517",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-01-18T16:15:08.350",
  "references": [
    {
      "source": "security@apache.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2022/01/18/4"
    },
    {
      "source": "security@apache.org",
      "tags": [
        "Issue Tracking",
        "Mailing List",
        "Vendor Advisory"
      ],
      "url": "https://lists.apache.org/thread/pt6lh3pbsvxqlwlp4c5l798dv2hkc85y"
    },
    {
      "source": "security@apache.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://logging.apache.org/log4j/1.2/index.html"
    },
    {
      "source": "security@apache.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20220217-0007/"
    },
    {
      "source": "security@apache.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
    },
    {
      "source": "security@apache.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2022/01/18/4"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Issue Tracking",
        "Mailing List",
        "Vendor Advisory"
      ],
      "url": "https://lists.apache.org/thread/pt6lh3pbsvxqlwlp4c5l798dv2hkc85y"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://logging.apache.org/log4j/1.2/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20220217-0007/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
    }
  ],
  "sourceIdentifier": "security@apache.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "security@apache.org",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-11-08 18:15
Modified
2024-11-21 04:30
Summary
The authentication mechanism, in Brocade SANnav versions before v2.0, logs plaintext account credentials at the ‘trace’ and the 'debug' logging level; which could allow a local authenticated attacker to access sensitive information.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CDB21EC-9E2B-4054-881F-63A89B247BF7",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The authentication mechanism, in Brocade SANnav versions before v2.0, logs plaintext account credentials at the \u2018trace\u2019 and the \u0027debug\u0027 logging level; which could allow a local authenticated attacker to access sensitive information."
    },
    {
      "lang": "es",
      "value": "El mecanismo de autenticaci\u00f3n, en las versiones de Brocade SANnav anteriores a la versi\u00f3n v2.0, registra las credenciales de la cuenta de texto sin formato en el nivel de registro de \"rastreo\" y \"depuraci\u00f3n\"; lo que podr\u00eda permitir que un atacante autenticado local acceda a informaci\u00f3n confidencial."
    }
  ],
  "id": "CVE-2019-16206",
  "lastModified": "2024-11-21T04:30:16.347",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 2.1,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-11-08T18:15:12.607",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-865"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-865"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-311"
        },
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-11-08 18:15
Modified
2024-11-21 04:30
Summary
Brocade SANnav versions before v2.0, logs plain text database connection password while triggering support save.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CDB21EC-9E2B-4054-881F-63A89B247BF7",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade SANnav versions before v2.0, logs plain text database connection password while triggering support save."
    },
    {
      "lang": "es",
      "value": "Brocade SANnav versiones anteriores a v2.0, registra una contrase\u00f1a de conexi\u00f3n de base de datos de texto plano mientras activa el guardado de soporte."
    }
  ],
  "id": "CVE-2019-16210",
  "lastModified": "2024-11-21T04:30:16.780",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 2.1,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-11-08T18:15:12.873",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-869"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-869"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-311"
        },
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-09-25 14:15
Modified
2024-11-21 04:30
Severity ?
Summary
Brocade SANnav versions before v2.1.0, contain a Plaintext Password Storage vulnerability.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A07E603E-4CAC-485C-BE69-2405AF84E138",
              "versionEndExcluding": "2.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade SANnav versions before v2.1.0, contain a Plaintext Password Storage vulnerability."
    },
    {
      "lang": "es",
      "value": "Brocade SANnav versiones anteriores a v2.1.0, contienen una vulnerabilidad de almacenamiento de contrase\u00f1a de texto plano"
    }
  ],
  "id": "CVE-2019-16211",
  "lastModified": "2024-11-21T04:30:16.890",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-09-25T14:15:13.330",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2020-1076"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2020-1076"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-18 02:15
Modified
2025-02-04 15:58
Summary
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints the Brocade SANnav password in clear text in supportsave logs when a user schedules a switch Supportsave from Brocade SANnav.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints the Brocade SANnav password in clear text in supportsave logs when a user schedules a switch Supportsave from Brocade SANnav.\n\n"
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en Brocade SANnav anterior a v2.3.1 y v2.3.0a imprime la contrase\u00f1a de Brocade SANnav en texto plano en los registros de guardado de soporte cuando un usuario programa un cambio de guardado de soporte desde Brocade SANnav."
    }
  ],
  "id": "CVE-2024-29956",
  "lastModified": "2025-02-04T15:58:26.297",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-18T02:15:06.797",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23240"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23240"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-31 01:15
Modified
2025-02-13 17:16
Summary
Possible information exposure through log file vulnerability where sensitive fields are recorded in the configuration log without masking on Brocade SANnav before v2.3.0 and 2.2.2a. Notes: To access the logs, the local attacker must have access to an already collected Brocade SANnav "supportsave" outputs.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D1A8656-FE4D-44EC-B72F-C15FAF7B465D",
              "versionEndExcluding": "2.2.2a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Possible\n information exposure through log file vulnerability where sensitive \nfields are recorded in the configuration log without masking on Brocade \nSANnav before v2.3.0 and 2.2.2a. Notes:\n To access the logs, the local attacker must have access to an already collected Brocade SANnav \"supportsave\" \noutputs."
    },
    {
      "lang": "es",
      "value": "Posible exposici\u00f3n de informaci\u00f3n a trav\u00e9s de la vulnerabilidad del archivo de registro donde se guardan campos sensibles en el registro de configuraci\u00f3n sin enmascarar en Brocade SANnav antes de v2.3.0 y 2.2.2a. Notas: Para acceder a los registros, el atacante local debe tener acceso a una salida \"supportsave\" de Brocade SANnav ya recopilada. "
    }
  ],
  "id": "CVE-2023-31423",
  "lastModified": "2025-02-13T17:16:27.747",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-31T01:15:07.860",
  "references": [
    {
      "source": "sirt@brocade.com",
      "url": "https://security.netapp.com/advisory/ntap-20240229-0003/"
    },
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22508"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://security.netapp.com/advisory/ntap-20240229-0003/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22508"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-11-21 11:15
Modified
2025-02-04 18:13
Summary
An information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where configuration secrets are logged in supportsave. Supportsave file is generated by an admin user troubleshooting the switch. The Logged information may include usernames and passwords, and secret keys.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC77C573-F6AD-451A-B543-682C9276861D",
              "versionEndExcluding": "2.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where configuration secrets are logged in supportsave. Supportsave file is generated by an admin user troubleshooting the switch. The Logged information may include usernames and passwords, and secret keys."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de exposici\u00f3n de informaci\u00f3n a trav\u00e9s de un archivo de registro en Brocade SANnav anterior a Brocade SANnav 2.2.2, donde los secretos de configuraci\u00f3n se registran en supportsave. El archivo supportsave lo genera un usuario administrador que soluciona problemas en el conmutador. La informaci\u00f3n registrada puede incluir nombres de usuario, contrase\u00f1as y claves secretas."
    }
  ],
  "id": "CVE-2022-43933",
  "lastModified": "2025-02-04T18:13:36.443",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 4.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 4.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-11-21T11:15:11.077",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/21221"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-538"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-07-09 12:15
Modified
2024-12-30 19:23
Severity ?
Summary
RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:freeradius:freeradius:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C73FF4C-13DE-4050-BD56-447F9382AA4D",
              "versionEndExcluding": "3.0.27",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75B1EDA5-F189-440D-AD0E-C70DD2C0FEE5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:broadcom:fabric_operating_system:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "046FB51E-B768-44D3-AEB5-D857145CA840",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sonicwall:sonicos:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CF61DAA-8295-4407-B125-1714E1565965",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature."
    },
    {
      "lang": "es",
      "value": "El protocolo RADIUS seg\u00fan RFC 2865 es susceptible a ataques de falsificaci\u00f3n por parte de un atacante local que puede modificar cualquier respuesta v\u00e1lida (acceso-aceptaci\u00f3n, acceso-rechazo o acceso-desaf\u00edo) a cualquier otra respuesta utilizando un ataque de colisi\u00f3n de prefijo elegido contra la firma del autenticador de respuesta MD5. ."
    }
  ],
  "id": "CVE-2024-3596",
  "lastModified": "2024-12-30T19:23:20.437",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.0,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 6.0,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-07-09T12:15:20.700",
  "references": [
    {
      "source": "cret@cert.org",
      "tags": [
        "Mailing List"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "Technical Description"
      ],
      "url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "Technical Description"
      ],
      "url": "https://datatracker.ietf.org/doc/html/rfc2865"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "Technical Description"
      ],
      "url": "https://www.blastradius.fail/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Technical Description"
      ],
      "url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Technical Description"
      ],
      "url": "https://datatracker.ietf.org/doc/html/rfc2865"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20240822-0001/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Technical Description"
      ],
      "url": "https://www.blastradius.fail/"
    }
  ],
  "sourceIdentifier": "cret@cert.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-354"
        },
        {
          "lang": "en",
          "value": "CWE-924"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-06-09 16:15
Modified
2024-11-21 05:05
Summary
Brocade SANnav before v.2.1.0a could allow remote attackers cause a denial-of-service condition due to a lack of proper validation, of the length of user-supplied data as name for custom field name.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D61C4E8-5464-4801-8556-BAD8FA6AB7E5",
              "versionEndIncluding": "2.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade SANnav before v.2.1.0a could allow remote attackers cause a denial-of-service condition due to a lack of proper validation, of the length of user-supplied data as name for custom field name."
    },
    {
      "lang": "es",
      "value": "Brocade SANnav versiones anteriores a 2.1.0a, pod\u00eda permitir a atacantes remotos causar una condici\u00f3n de denegaci\u00f3n de servicio debido a una falta de comprobaci\u00f3n apropiada, de la longitud de los datos suministrados por el usuario como como el nombre del campo personalizado"
    }
  ],
  "id": "CVE-2020-15379",
  "lastModified": "2024-11-21T05:05:26.960",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-06-09T16:15:08.133",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1319"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1319"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-31 01:15
Modified
2025-02-13 17:16
Summary
Brocade SANnav Web interface before Brocade SANnav v2.3.0 and v2.2.2a allows remote unauthenticated users to bypass web authentication and authorization.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D1A8656-FE4D-44EC-B72F-C15FAF7B465D",
              "versionEndExcluding": "2.2.2a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade SANnav Web interface before Brocade SANnav v2.3.0 and v2.2.2a\n allows remote unauthenticated users to bypass web authentication and \nauthorization."
    },
    {
      "lang": "es",
      "value": "La interfaz web Brocade SANnav v2.3.0 y v2.2.2a permite a usuarios remotos no autenticados eludir la autenticaci\u00f3n y autorizaci\u00f3n web. "
    }
  ],
  "id": "CVE-2023-31424",
  "lastModified": "2025-02-13T17:16:27.887",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 5.9,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-31T01:15:08.537",
  "references": [
    {
      "source": "sirt@brocade.com",
      "url": "https://security.netapp.com/advisory/ntap-20240229-0004/"
    },
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22507"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://security.netapp.com/advisory/ntap-20240229-0004/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22507"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-290"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-25 08:15
Modified
2025-02-06 17:53
Summary
A vulnerability in Brocade SANnav exposes Kafka in the wan interface. The vulnerability could allow an unauthenticated attacker to perform various attacks, including DOS against the Brocade SANnav.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "82F550F3-E967-4C24-9EE0-D3E8EA920D1B",
              "versionEndExcluding": "2.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nA vulnerability in Brocade SANnav exposes Kafka in the wan interface.\n\nThe vulnerability could allow an unauthenticated attacker to perform various attacks, including DOS against the Brocade SANnav.\n\n"
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en las versiones ova de Brocade SANnav anteriores a Brocade SANnav v2.3.1 y v2.3.0a expone a Kafka en la interfaz wan. La vulnerabilidad podr\u00eda permitir que un atacante no autenticado realice varios ataques, incluido DOS, el dispositivo Brocade SANnav."
    }
  ],
  "id": "CVE-2024-4173",
  "lastModified": "2025-02-06T17:53:25.287",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 4.7,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-25T08:15:07.977",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Not Applicable"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23285"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Not Applicable"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23285"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-25 06:16
Modified
2025-02-06 17:49
Summary
Brocade SANnav before v2.3.0a lacks protection mechanisms on port 2377/TCP and 7946/TCP, which could allow an unauthenticated attacker to sniff the SANnav Docker information.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nBrocade SANnav before v2.3.0a lacks protection mechanisms on port 2377/TCP and 7946/TCP, which could allow an unauthenticated attacker to sniff the SANnav Docker information.\n\n"
    },
    {
      "lang": "es",
      "value": "Brocade SANnav anterior a Brocade SANnav v2.3.1 carece de mecanismos de protecci\u00f3n en los puertos 2377/TCP y 7946/TCP, lo que podr\u00eda permitir que un atacante remoto no autenticado acceda a las API de Kafka y env\u00ede datos maliciosos."
    }
  ],
  "id": "CVE-2024-4159",
  "lastModified": "2025-02-06T17:49:55.727",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 1.4,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-25T06:16:00.560",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23282"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23282"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-06-09 15:15
Modified
2024-11-21 05:05
Summary
Brocade SANnav before version 2.1.1 uses a hard-coded administrator account with the weak password ‘passw0rd’ if a password is not provided for PostgreSQL at install-time.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F078016A-D256-4A68-9C65-DF23B6858158",
              "versionEndExcluding": "2.1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade SANnav before version 2.1.1 uses a hard-coded administrator account with the weak password \u2018passw0rd\u2019 if a password is not provided for PostgreSQL at install-time."
    },
    {
      "lang": "es",
      "value": "Brocade SANnav versiones anteriores a 2.1.1, usa una cuenta de administrador codificada con la contrase\u00f1a d\u00e9bil \"passw0rd\" si no es proporcionado una contrase\u00f1a para PostgreSQL en el momento de la instalaci\u00f3n"
    }
  ],
  "id": "CVE-2020-15382",
  "lastModified": "2024-11-21T05:05:27.287",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-06-09T15:15:08.073",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1484"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1484"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-19 04:15
Modified
2025-02-04 15:54
Summary
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints Brocade Fabric OS switch encrypted passwords in the Brocade SANnav Standby node's support save.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints Brocade Fabric OS switch encrypted passwords in the Brocade SANnav Standby node\u0027s support save.\n\n"
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en Brocade SANnav anterior a v2.3.1 y v2.3.0a imprime contrase\u00f1as cifradas del conmutador Brocade Fabric OS en el guardado de soporte del nodo Brocade SANnav Standby."
    }
  ],
  "id": "CVE-2024-29959",
  "lastModified": "2025-02-04T15:54:42.997",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 8.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.0,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 8.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.0,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-19T04:15:10.020",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23243"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23243"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-19 06:15
Modified
2025-02-04 15:41
Summary
When a Brocade SANnav installation is upgraded from Brocade SANnav v2.2.2 to Brocade SANnav 2.3.0, TLS/SSL weak message authentication code ciphers are added by default for port 18082.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD6E430B-7C3A-4B79-987A-302A27CEBFCC",
              "versionEndExcluding": "2.3.0a",
              "versionStartIncluding": "2.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "When a Brocade SANnav installation is upgraded from Brocade SANnav v2.2.2 to Brocade SANnav 2.3.0, TLS/SSL weak message authentication code ciphers are added by default for port 18082. \n\n"
    },
    {
      "lang": "es",
      "value": "Cuando se actualiza una instalaci\u00f3n de Brocade SANnav de Brocade SANnav v2.2.2 a Brocade SANnav 2.3.0, los cifrados de c\u00f3digos de autenticaci\u00f3n de mensajes d\u00e9biles TLS/SSL se agregan de forma predeterminada para el puerto 18082."
    }
  ],
  "id": "CVE-2024-29969",
  "lastModified": "2025-02-04T15:41:14.437",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-19T06:15:07.753",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23251"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23251"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-326"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-326"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-19 04:15
Modified
2025-02-04 15:57
Summary
When Brocade SANnav before v2.3.1 and v2.3.0a servers are configured in Disaster Recovery mode, the encryption key is stored in the DR log files. This could provide attackers with an additional, less-protected path to acquiring the encryption key.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "When Brocade SANnav before v2.3.1 and v2.3.0a servers are configured in Disaster Recovery mode, the encryption key is stored in the DR log files. This could provide attackers with an additional, less-protected path to acquiring the encryption key.\n"
    },
    {
      "lang": "es",
      "value": "Cuando los servidores Brocade SANnav anteriores a v2.3.1 y v2.3.0a est\u00e1n configurados en modo de recuperaci\u00f3n de desastres, la clave de cifrado se almacena en los archivos de registro de recuperaci\u00f3n ante desastres. Esto podr\u00eda proporcionar a los atacantes una ruta adicional y menos protegida para adquirir la clave de cifrado."
    }
  ],
  "id": "CVE-2024-29957",
  "lastModified": "2025-02-04T15:57:57.087",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-19T04:15:09.390",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23241"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23241"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-19 04:15
Modified
2025-02-04 15:53
Summary
In Brocade SANnav server before v2.3.1 and v2.3.0a, the SSH keys inside the OVA image are identical in the VM every time SANnav is installed. Any Brocade SAnnav VM based on the official OVA images is vulnerable to MITM over SSH. An attacker can decrypt and compromise the SSH traffic to the SANnav.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nIn Brocade SANnav server before v2.3.1 and v2.3.0a, the SSH keys inside the OVA image are identical in the VM every time SANnav is installed. Any Brocade SAnnav VM based on the official OVA images is vulnerable to MITM over SSH. An attacker can decrypt and compromise the SSH traffic to the SANnav.\n\n"
    },
    {
      "lang": "es",
      "value": "En las versiones del servidor Brocade SANnav anteriores a v2.3.1 y v2.3.0a, las claves SSH dentro de la imagen OVA est\u00e1n codificadas y son id\u00e9nticas en la VM cada vez que se instala SANnav. Cualquier m\u00e1quina virtual Brocade SANnav basada en las im\u00e1genes OVA oficiales es vulnerable a MITM a trav\u00e9s de SSH. Un atacante puede descifrar y comprometer el tr\u00e1fico SSH al dispositivo SANnav."
    }
  ],
  "id": "CVE-2024-29960",
  "lastModified": "2025-02-04T15:53:21.440",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 5.9,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-19T04:15:10.270",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23244"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23244"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-05-08 02:15
Modified
2025-02-06 17:54
Summary
The PostgreSQL implementation in Brocade SANnav versions before 2.3.0a is vulnerable to an incorrect local authentication flaw. An attacker accessing the VM where the Brocade SANnav is installed can gain access to sensitive data inside the PostgreSQL database.
Impacted products
Vendor Product Version
broadcom brocade_sannav *
broadcom brocade_sannav 2.3.1



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:2.3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "4578C225-0362-4DD2-9640-BA42C07ACC96",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The PostgreSQL implementation in Brocade SANnav versions before 2.3.0a is vulnerable to an incorrect local authentication flaw. An attacker accessing the VM where the Brocade SANnav is installed can gain access to sensitive data inside the PostgreSQL database.\n "
    },
    {
      "lang": "es",
      "value": "La implementaci\u00f3n de PostgreSQL en las versiones de Brocade SANnav anteriores a la 2.3.0a es vulnerable a una falla de autenticaci\u00f3n local incorrecta. Un atacante que acceda a la m\u00e1quina virtual donde est\u00e1 instalado Brocade SANnav puede obtener acceso a datos confidenciales dentro de la base de datos PostgreSQL."
    }
  ],
  "id": "CVE-2024-2860",
  "lastModified": "2025-02-06T17:54:45.057",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-05-08T02:15:09.873",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/24260"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/24260"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-19 05:15
Modified
2025-02-04 15:44
Summary
Brocade SANnav OVA before v2.3.1 and v2.3.0a contain hard-coded credentials in the documentation that appear as the appliance's root password. The vulnerability could allow an unauthenticated attacker full access to the Brocade SANnav appliance.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade SANnav OVA before v2.3.1 and v2.3.0a contain hard-coded credentials in the documentation that appear as the appliance\u0027s root password. The vulnerability could allow an unauthenticated attacker full access to the Brocade SANnav appliance.\n\n"
    },
    {
      "lang": "es",
      "value": "Brocade SANnav OVA anterior a v2.3.1 y v2.3.0a contiene credenciales codificadas en la documentaci\u00f3n que aparecen como la contrase\u00f1a ra\u00edz del dispositivo. La vulnerabilidad podr\u00eda permitir a un atacante no autenticado acceso completo al dispositivo Brocade SANnav."
    }
  ],
  "id": "CVE-2024-29966",
  "lastModified": "2025-02-04T15:44:24.547",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-19T05:15:49.567",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23255"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23255"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-19 06:15
Modified
2025-02-04 15:41
Summary
An information disclosure vulnerability exists in Brocade SANnav before v2.3.1 and v2.3.0a when Brocade SANnav instances are configured in disaster recovery mode. SQL Table names, column names, and SQL queries are collected in DR standby Supportsave. This could allow authenticated users to access the database structure and its contents.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "303EE152-4CED-4655-B035-CB3B91E5E288",
              "versionEndExcluding": "2.3.0a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An information disclosure vulnerability exists in Brocade SANnav before v2.3.1 and v2.3.0a when Brocade SANnav instances are configured in disaster recovery mode. SQL Table names, column names, and SQL queries are collected in DR standby Supportsave. This could allow authenticated users to access the database structure and its contents."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n en Brocade SANnav anterior a v2.3.1 y v2.3.0a cuando las instancias de Brocade SANnav est\u00e1n configuradas en modo de recuperaci\u00f3n ante desastres. Los nombres de las tablas SQL, los nombres de las columnas y las consultas SQL se recopilan en Supportsave en espera de DR. Esto podr\u00eda permitir a los usuarios autenticados acceder a la estructura de la base de datos y su contenido."
    }
  ],
  "id": "CVE-2024-29968",
  "lastModified": "2025-02-04T15:41:56.900",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.7,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.1,
        "impactScore": 4.0,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-19T06:15:06.497",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23253"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23253"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-922"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-922"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-04-25 06:16
Modified
2025-02-06 17:50
Summary
In Brocade SANnav, before Brocade SANnav v2.3.0, syslog traffic received clear text. This could allow an unauthenticated, remote attacker to capture sensitive information.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D4FED58-4527-4735-87F8-80B5664B7B4F",
              "versionEndExcluding": "2.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Brocade SANnav, before Brocade SANnav v2.3.0, syslog traffic received\n clear text. This could allow an unauthenticated, remote attacker to \ncapture sensitive information.\n\n"
    },
    {
      "lang": "es",
      "value": "En Brocade SANnav, antes de Brocade SANnav v2.3.0, el tr\u00e1fico de syslog recib\u00eda texto plano. Esto podr\u00eda permitir que un atacante remoto no autenticado capture informaci\u00f3n confidencial."
    }
  ],
  "id": "CVE-2024-4161",
  "lastModified": "2025-02-06T17:50:45.147",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 8.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.0,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-25T06:16:01.427",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23284"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23284"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-319"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-319"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-11-21 11:15
Modified
2025-02-04 18:19
Summary
Possible information exposure through log file vulnerability where sensitive fields are recorded in the debug-enabled logs when debugging is turned on in Brocade SANnav before 2.3.0 and 2.2.2a
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D1A8656-FE4D-44EC-B72F-C15FAF7B465D",
              "versionEndExcluding": "2.2.2a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Possible information exposure through log file vulnerability where sensitive fields are recorded in the debug-enabled logs when debugging is turned on in Brocade SANnav before 2.3.0 and 2.2.2a"
    },
    {
      "lang": "es",
      "value": "Posible exposici\u00f3n de informaci\u00f3n a trav\u00e9s de una vulnerabilidad en el archivo de registro donde se registran campos confidenciales en los registros habilitados para depuraci\u00f3n cuando la depuraci\u00f3n est\u00e1 activada en Brocade SANnav anterior a 2.3.0 y 2.2.2a"
    }
  ],
  "id": "CVE-2022-43937",
  "lastModified": "2025-02-04T18:19:12.883",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 3.6,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-11-21T11:15:14.733",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22509"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20240229-0005/"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-11-08 18:15
Modified
2024-11-21 04:30
Summary
A vulnerability, in The ReportsTrustManager class of Brocade SANnav versions before v2.0, could allow an attacker to perform a man-in-the-middle attack against Secure Sockets Layer(SSL)connections.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CDB21EC-9E2B-4054-881F-63A89B247BF7",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability, in The ReportsTrustManager class of Brocade SANnav versions before v2.0, could allow an attacker to perform a man-in-the-middle attack against Secure Sockets Layer(SSL)connections."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad, en la clase The ReportsTrustManager de Brocade SANnav versiones anteriores a v2.0, podr\u00eda permitir a un atacante realizar un ataque man-in-the-middle contra conexiones Secure Sockets Layer (SSL)."
    }
  ],
  "id": "CVE-2019-16209",
  "lastModified": "2024-11-21T04:30:16.673",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.4,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-11-08T18:15:12.810",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-868"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-868"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-295"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-08-31 01:15
Modified
2024-11-21 08:02
Summary
Brocade SANnav before v2.3.0 and v2.2.2a stores SNMPv3 Authentication passwords in plaintext. A privileged user could retrieve these credentials with knowledge and access to these log files. SNMP credentials could be seen in SANnav SupportSave if the capture is performed after an SNMP configuration failure causes an SNMP communication log dump.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D1A8656-FE4D-44EC-B72F-C15FAF7B465D",
              "versionEndExcluding": "2.2.2a",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade\n SANnav before v2.3.0 and v2.2.2a stores SNMPv3 Authentication passwords\n in plaintext. A privileged user could retrieve these credentials with \nknowledge and access to these log files. SNMP \ncredentials could be seen in SANnav SupportSave if the capture is \nperformed after an SNMP configuration failure causes an SNMP \ncommunication log dump.\n\n\n"
    },
    {
      "lang": "es",
      "value": "Brocade SANnav antes de v2.3.0 y v2.2.2a almacena las contrase\u00f1as de autenticaci\u00f3n SNMPv3 en texto plano. Un usuario con privilegios podr\u00eda recuperar estas credenciales con conocimiento y acceso a estos archivos de registro. Las credenciales SNMP podr\u00edan verse en SANnav SupportSave si la captura se realiza despu\u00e9s de que un fallo de configuraci\u00f3n SNMP provoque un volcado de registro de comunicaci\u00f3n SNMP. "
    }
  ],
  "id": "CVE-2023-31925",
  "lastModified": "2024-11-21T08:02:24.340",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.5,
        "source": "sirt@brocade.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-08-31T01:15:08.753",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22506"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22506"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "sirt@brocade.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-09-25 14:15
Modified
2024-11-21 04:30
Summary
A vulnerability in Brocade SANnav versions before v2.1.0 could allow a remote authenticated attacker to conduct an LDAP injection. The vulnerability could allow a remote attacker to bypass the authentication process.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A07E603E-4CAC-485C-BE69-2405AF84E138",
              "versionEndExcluding": "2.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in Brocade SANnav versions before v2.1.0 could allow a remote authenticated attacker to conduct an LDAP injection. The vulnerability could allow a remote attacker to bypass the authentication process."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en Brocade SANnav versiones anteriores a v2.1.0, podr\u00eda permitir a un atacante autenticado remoto llevar a cabo una inyecci\u00f3n del LDAP.\u0026#xa0;La vulnerabilidad podr\u00eda permitir a un atacante remoto omitir el proceso de autenticaci\u00f3n"
    }
  ],
  "id": "CVE-2019-16212",
  "lastModified": "2024-11-21T04:30:17.003",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-09-25T14:15:13.393",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2020-1074"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2020-1074"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-11-08 18:15
Modified
2024-11-21 04:30
Summary
Brocade SANnav versions before v2.0 use a hard-coded password, which could allow local authenticated attackers to access a back-end database and gain privileges.
Impacted products
Vendor Product Version
broadcom brocade_sannav *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CDB21EC-9E2B-4054-881F-63A89B247BF7",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Brocade SANnav versions before v2.0 use a hard-coded password, which could allow local authenticated attackers to access a back-end database and gain privileges."
    },
    {
      "lang": "es",
      "value": "Brocade SANnav versiones anteriores a v2.0, utilizan una contrase\u00f1a embebida, lo que podr\u00eda permitir a atacantes autenticados locales acceder a una base de datos del back-end y alcanzar privilegios."
    }
  ],
  "id": "CVE-2019-16207",
  "lastModified": "2024-11-21T04:30:16.453",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-11-08T18:15:12.670",
  "references": [
    {
      "source": "sirt@brocade.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-866"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-866"
    }
  ],
  "sourceIdentifier": "sirt@brocade.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2024-29952
Vulnerability from cvelistv5
Published
2024-04-17 21:43
Modified
2024-08-02 01:17
Summary
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a could allow an authenticated user to print the Auth, Priv, and SSL key store passwords in unencrypted logs by manipulating command variables.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1 and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29952",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-19T15:24:31.427599Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:56:41.588Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.546Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23238"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1 and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a could allow an authenticated user to print the Auth, Priv, and SSL key store passwords in unencrypted logs by manipulating command variables.\u003cbr\u003e\n\n"
            }
          ],
          "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a could allow an authenticated user to print the Auth, Priv, and SSL key store passwords in unencrypted logs by manipulating command variables.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37: Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": " CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-17T21:43:57.482Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23238"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Clear text storage of sensistive information by manipulating command variables ",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29952",
    "datePublished": "2024-04-17T21:43:57.482Z",
    "dateReserved": "2024-03-22T05:00:09.537Z",
    "dateUpdated": "2024-08-02T01:17:58.546Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31925
Vulnerability from cvelistv5
Published
2023-08-31 00:20
Modified
2024-09-27 19:12
Summary
Brocade SANnav before v2.3.0 and v2.2.2a stores SNMPv3 Authentication passwords in plaintext. A privileged user could retrieve these credentials with knowledge and access to these log files. SNMP credentials could be seen in SANnav SupportSave if the capture is performed after an SNMP configuration failure causes an SNMP communication log dump.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: Brocade SANnav before v2.3.0 and v2.2.2a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T15:03:28.526Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22506"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31925",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-27T18:22:50.419342Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-27T19:12:13.928Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade SANnav before v2.3.0 and v2.2.2a "
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Brocade\n SANnav before v2.3.0 and v2.2.2a stores SNMPv3 Authentication passwords\n in plaintext. A privileged user could retrieve these credentials with \nknowledge and access to these log files. SNMP \ncredentials could be seen in SANnav SupportSave if the capture is \nperformed after an SNMP configuration failure causes an SNMP \ncommunication log dump.\n\n\n"
            }
          ],
          "value": "Brocade\n SANnav before v2.3.0 and v2.2.2a stores SNMPv3 Authentication passwords\n in plaintext. A privileged user could retrieve these credentials with \nknowledge and access to these log files. SNMP \ncredentials could be seen in SANnav SupportSave if the capture is \nperformed after an SNMP configuration failure causes an SNMP \ncommunication log dump.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-31T00:20:31.179Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22506"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Storage of clear text password in Brocade SANnav",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-31925",
    "datePublished": "2023-08-31T00:20:30.874Z",
    "dateReserved": "2023-04-29T01:29:30.559Z",
    "dateUpdated": "2024-09-27T19:12:13.928Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29959
Vulnerability from cvelistv5
Published
2024-04-19 03:19
Modified
2024-08-02 01:17
Summary
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints Brocade Fabric OS switch encrypted passwords in the Brocade SANnav Standby node's support save.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1 and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29959",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-19T15:02:11.676881Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:57:31.410Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.492Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23243"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1 and v2.3.0a "
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints Brocade Fabric OS switch encrypted passwords in the Brocade SANnav Standby node\u0027s support save.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints Brocade Fabric OS switch encrypted passwords in the Brocade SANnav Standby node\u0027s support save.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-19T03:19:28.271Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23243"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Brocade Fabric OS switch encrypted passwords in the Brocade SANnav Standby node\u0027s support save",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29959",
    "datePublished": "2024-04-19T03:19:28.271Z",
    "dateReserved": "2024-03-22T05:18:44.193Z",
    "dateUpdated": "2024-08-02T01:17:58.492Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29969
Vulnerability from cvelistv5
Published
2024-04-19 05:24
Modified
2024-08-02 01:17
Summary
When a Brocade SANnav installation is upgraded from Brocade SANnav v2.2.2 to Brocade SANnav 2.3.0, TLS/SSL weak message authentication code ciphers are added by default for port 18082.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1, v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "2.3.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29969",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-19T18:15:49.158705Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:56:58.604Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.693Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23251"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1, v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "When a Brocade SANnav installation is upgraded from Brocade SANnav v2.2.2 to Brocade SANnav 2.3.0, TLS/SSL weak message authentication code ciphers are added by default for port 18082. \u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "When a Brocade SANnav installation is upgraded from Brocade SANnav v2.2.2 to Brocade SANnav 2.3.0, TLS/SSL weak message authentication code ciphers are added by default for port 18082. \n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-20",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-20 Encryption Brute Forcing"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326 Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-19T05:24:44.930Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23251"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "TLS/SSL weak message authentication code ciphers are added by default for port 18082",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29969",
    "datePublished": "2024-04-19T05:24:44.930Z",
    "dateReserved": "2024-03-22T05:32:26.687Z",
    "dateUpdated": "2024-08-02T01:17:58.693Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-3596
Vulnerability from cvelistv5
Published
2024-07-09 12:02
Modified
2025-02-13 17:52
Severity ?
Summary
RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature.
Impacted products
Vendor Product Version
IETF RFC Version: 2865
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ietf:rfc:2865:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rfc",
            "vendor": "ietf",
            "versions": [
              {
                "status": "affected",
                "version": "2865"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-3596",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-11T03:55:37.141738Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-24T20:18:28.202Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-29T14:32:14.851Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://security.netapp.com/advisory/ntap-20240822-0001/"
          },
          {
            "url": "https://today.ucsd.edu/story/computer-scientists-discover-vulnerabilities-in-a-popular-security-protocol"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://datatracker.ietf.org/doc/html/rfc2865"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.blastradius.fail/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
          }
        ],
        "title": "CVE Program Container",
        "x_generator": {
          "engine": "ADPogram 0.0.1"
        }
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RFC",
          "vendor": "IETF",
          "versions": [
            {
              "status": "affected",
              "version": "2865"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Thanks to Sharon Goldberg, Miro Haller, Nadia Heninger, Mike Milano, Dan Shumow, Marc Stevens, and Adam Suhl who researched and reported this vulnerability"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-328: Use of Weak Hash",
              "lang": "en"
            }
          ]
        },
        {
          "descriptions": [
            {
              "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en"
            }
          ]
        },
        {
          "descriptions": [
            {
              "description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-23T09:05:59.827Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "url": "https://datatracker.ietf.org/doc/html/rfc2865"
        },
        {
          "url": "https://datatracker.ietf.org/doc/draft-ietf-radext-deprecating-radius/"
        },
        {
          "url": "https://networkradius.com/assets/pdf/radius_and_md5_collisions.pdf"
        },
        {
          "url": "https://www.blastradius.fail/"
        },
        {
          "url": "http://www.openwall.com/lists/oss-security/2024/07/09/4"
        },
        {
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0014"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "RADIUS Protocol under RFC2865 is vulnerable to forgery attacks.",
      "x_generator": {
        "engine": "VINCE 3.0.4",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2024-3596"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2024-3596",
    "datePublished": "2024-07-09T12:02:53.001Z",
    "dateReserved": "2024-04-10T15:09:45.391Z",
    "dateUpdated": "2025-02-13T17:52:35.412Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-43936
Vulnerability from cvelistv5
Published
2024-11-21 03:04
Modified
2024-11-21 18:01
Summary
Brocade SANnav versions before 2.2.2 log Brocade Fabric OS switch passwords when debugging is enabled.
Impacted products
Vendor Product Version
Brocade SANnav Version: before Brocade SANnav 2.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43936",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T17:55:56.798864Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T18:01:26.562Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before Brocade SANnav 2.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eBrocade SANnav versions before 2.2.2 log Brocade Fabric OS switch passwords when debugging is enabled.\u003c/p\u003e"
            }
          ],
          "value": "Brocade SANnav versions before 2.2.2 log Brocade Fabric OS switch passwords when debugging is enabled."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37: Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-21T03:04:53.160Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/21218"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Brocade Fabric OS switch passwords when debugging is enabled",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2022-43936",
    "datePublished": "2024-11-21T03:04:52.786Z",
    "dateReserved": "2022-10-26T19:34:16.362Z",
    "dateUpdated": "2024-11-21T18:01:26.562Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29951
Vulnerability from cvelistv5
Published
2024-04-17 19:21
Modified
2024-08-02 01:17
Summary
Brocade SANnav before v2.3.1 and v2.3.0a uses the SHA-1 hash in internal SSH ports that are not open to remote connection.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1 and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29951",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-23T21:29:52.528317Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:58:14.213Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.619Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23237"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1 and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Brocade SANnav before v2.3.1 and v2.3.0a uses the SHA-1 hash in internal SSH ports that are not open to remote connection.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "Brocade SANnav before v2.3.1 and v2.3.0a uses the SHA-1 hash in internal SSH ports that are not open to remote connection.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-97",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-97 Cryptanalysis"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326 Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-17T19:21:32.090Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23237"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Brocade SANnav has weak encryption in internal SSH ports",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29951",
    "datePublished": "2024-04-17T19:21:32.090Z",
    "dateReserved": "2024-03-22T05:00:09.537Z",
    "dateUpdated": "2024-08-02T01:17:58.619Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29965
Vulnerability from cvelistv5
Published
2024-04-19 04:48
Modified
2024-08-02 01:17
Summary
In Brocade SANnav before v2.3.1, and v2.3.0a, it is possible to back up the appliance from the web interface or the command line interface ("SSH"). The resulting backups are world-readable. A local attacker can recover backup files, restore them to a new malicious appliance, and retrieve the passwords of all the switches.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1, and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29965",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-20T03:00:28.543253Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:56:52.975Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.599Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23250"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": " before v2.3.1, and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Brocade SANnav before v2.3.1, and v2.3.0a, it is possible to back up the appliance from the web interface or the command line interface (\"SSH\"). The resulting backups are world-readable. A local attacker can recover backup files, restore them to a new malicious appliance, and retrieve the passwords of all the switches.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nIn Brocade SANnav before v2.3.1, and v2.3.0a, it is possible to back up the appliance from the web interface or the command line interface (\"SSH\"). The resulting backups are world-readable. A local attacker can recover backup files, restore them to a new malicious appliance, and retrieve the passwords of all the switches.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-922",
              "description": "CWE-922: Insecure Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-19T04:55:03.276Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23250"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insecure backup",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29965",
    "datePublished": "2024-04-19T04:48:46.279Z",
    "dateReserved": "2024-03-22T05:32:26.687Z",
    "dateUpdated": "2024-08-02T01:17:58.599Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-16206
Vulnerability from cvelistv5
Published
2019-11-08 17:18
Modified
2024-08-05 01:10
Severity ?
Summary
The authentication mechanism, in Brocade SANnav versions before v2.0, logs plaintext account credentials at the ‘trace’ and the 'debug' logging level; which could allow a local authenticated attacker to access sensitive information.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:10:41.537Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-865"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Brocade SANnav",
          "vendor": "Brocade Communications Systems, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "versions before v2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The authentication mechanism, in Brocade SANnav versions before v2.0, logs plaintext account credentials at the \u2018trace\u2019 and the \u0027debug\u0027 logging level; which could allow a local authenticated attacker to access sensitive information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information Exposure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-08T17:18:31",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-865"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@brocade.com",
          "ID": "CVE-2019-16206",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Brocade SANnav",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions before v2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Brocade Communications Systems, Inc."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The authentication mechanism, in Brocade SANnav versions before v2.0, logs plaintext account credentials at the \u2018trace\u2019 and the \u0027debug\u0027 logging level; which could allow a local authenticated attacker to access sensitive information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-865",
              "refsource": "CONFIRM",
              "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-865"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2019-16206",
    "datePublished": "2019-11-08T17:18:31",
    "dateReserved": "2019-09-10T00:00:00",
    "dateUpdated": "2024-08-05T01:10:41.537Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29963
Vulnerability from cvelistv5
Published
2024-04-19 04:04
Modified
2024-08-02 01:17
Summary
Brocade SANnav OVA before v2.3.1, and v2.3.0a, contain hardcoded TLS keys used by Docker. Note: Brocade SANnav doesn't have access to remote Docker registries.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1, and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThanOrEqual": "2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29963",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-01T15:55:28.577181Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-18T18:11:24.943Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.554Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23247"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1, and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eBrocade SANnav OVA before v2.3.1, and v2.3.0a, contain hardcoded TLS keys used by Docker. Note: Brocade SANnav doesn\u0027t have access to remote Docker registries.\u003c/p\u003e"
            }
          ],
          "value": "\nBrocade SANnav OVA before v2.3.1, and v2.3.0a, contain hardcoded TLS keys used by Docker. Note: Brocade SANnav doesn\u0027t have access to remote Docker registries.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 1.9,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-26T22:23:04.859Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23247"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Brocade SANnav contains hardcoded TLS keys used by Docker",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29963",
    "datePublished": "2024-04-19T04:04:48.344Z",
    "dateReserved": "2024-03-22T05:23:33.322Z",
    "dateUpdated": "2024-08-02T01:17:58.554Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-23305
Vulnerability from cvelistv5
Published
2022-01-18 15:25
Modified
2024-08-03 03:36
Severity ?
Summary
By design, the JDBCAppender in Log4j 1.2.x accepts an SQL statement as a configuration parameter where the values to be inserted are converters from PatternLayout. The message converter, %m, is likely to always be included. This allows attackers to manipulate the SQL by entering crafted strings into input fields or headers of an application that are logged allowing unintended SQL queries to be executed. Note this issue only affects Log4j 1.x when specifically configured to use the JDBCAppender, which is not the default. Beginning in version 2.0-beta8, the JDBCAppender was re-introduced with proper support for parameterized SQL queries and further customization over the columns written to in logs. Apache Log4j 1.2 reached end of life in August 2015. Users should upgrade to Log4j 2 as it addresses numerous other issues from the previous versions.
Impacted products
Vendor Product Version
Apache Software Foundation Apache Log4j 1.x Version: 1.2.1   < unspecified
Version: unspecified   < 2.0-alpha1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:36:20.421Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://logging.apache.org/log4j/1.2/index.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://lists.apache.org/thread/pt6lh3pbsvxqlwlp4c5l798dv2hkc85y"
          },
          {
            "name": "[oss-security] 20220118 CVE-2022-23305: SQL injection in JDBC Appender in Apache Log4j V1",
            "tags": [
              "mailing-list",
              "x_refsource_MLIST",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2022/01/18/4"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20220217-0007/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Apache Log4j 1.x ",
          "vendor": "Apache Software Foundation",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "1.2.1",
              "versionType": "custom"
            },
            {
              "lessThan": "2.0-alpha1",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Daniel Martin of NCC Group"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "By design, the JDBCAppender in Log4j 1.2.x accepts an SQL statement as a configuration parameter where the values to be inserted are converters from PatternLayout. The message converter, %m, is likely to always be included. This allows attackers to manipulate the SQL by entering crafted strings into input fields or headers of an application that are logged allowing unintended SQL queries to be executed. Note this issue only affects Log4j 1.x when specifically configured to use the JDBCAppender, which is not the default. Beginning in version 2.0-beta8, the JDBCAppender was re-introduced with proper support for parameterized SQL queries and further customization over the columns written to in logs. Apache Log4j 1.2 reached end of life in August 2015. Users should upgrade to Log4j 2 as it addresses numerous other issues from the previous versions."
        }
      ],
      "metrics": [
        {
          "other": {
            "content": {
              "other": "high"
            },
            "type": "unknown"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-25T16:49:18",
        "orgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
        "shortName": "apache"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://logging.apache.org/log4j/1.2/index.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://lists.apache.org/thread/pt6lh3pbsvxqlwlp4c5l798dv2hkc85y"
        },
        {
          "name": "[oss-security] 20220118 CVE-2022-23305: SQL injection in JDBC Appender in Apache Log4j V1",
          "tags": [
            "mailing-list",
            "x_refsource_MLIST"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2022/01/18/4"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220217-0007/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "SQL injection in JDBC Appender in Apache Log4j V1",
      "workarounds": [
        {
          "lang": "en",
          "value": "Users should upgrade to Log4j 2 or remove usage of the JDBCAppender from their configurations."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@apache.org",
          "ID": "CVE-2022-23305",
          "STATE": "PUBLIC",
          "TITLE": "SQL injection in JDBC Appender in Apache Log4j V1"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Apache Log4j 1.x ",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003e=",
                            "version_value": "1.2.1"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_value": "2.0-alpha1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Apache Software Foundation"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Daniel Martin of NCC Group"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "By design, the JDBCAppender in Log4j 1.2.x accepts an SQL statement as a configuration parameter where the values to be inserted are converters from PatternLayout. The message converter, %m, is likely to always be included. This allows attackers to manipulate the SQL by entering crafted strings into input fields or headers of an application that are logged allowing unintended SQL queries to be executed. Note this issue only affects Log4j 1.x when specifically configured to use the JDBCAppender, which is not the default. Beginning in version 2.0-beta8, the JDBCAppender was re-introduced with proper support for parameterized SQL queries and further customization over the columns written to in logs. Apache Log4j 1.2 reached end of life in August 2015. Users should upgrade to Log4j 2 as it addresses numerous other issues from the previous versions."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": [
          {
            "other": "high"
          }
        ],
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://logging.apache.org/log4j/1.2/index.html",
              "refsource": "MISC",
              "url": "https://logging.apache.org/log4j/1.2/index.html"
            },
            {
              "name": "https://lists.apache.org/thread/pt6lh3pbsvxqlwlp4c5l798dv2hkc85y",
              "refsource": "MISC",
              "url": "https://lists.apache.org/thread/pt6lh3pbsvxqlwlp4c5l798dv2hkc85y"
            },
            {
              "name": "[oss-security] 20220118 CVE-2022-23305: SQL injection in JDBC Appender in Apache Log4j V1",
              "refsource": "MLIST",
              "url": "http://www.openwall.com/lists/oss-security/2022/01/18/4"
            },
            {
              "name": "https://www.oracle.com/security-alerts/cpuapr2022.html",
              "refsource": "MISC",
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20220217-0007/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20220217-0007/"
            },
            {
              "name": "https://www.oracle.com/security-alerts/cpujul2022.html",
              "refsource": "MISC",
              "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Users should upgrade to Log4j 2 or remove usage of the JDBCAppender from their configurations."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
    "assignerShortName": "apache",
    "cveId": "CVE-2022-23305",
    "datePublished": "2022-01-18T15:25:22",
    "dateReserved": "2022-01-17T00:00:00",
    "dateUpdated": "2024-08-03T03:36:20.421Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-43937
Vulnerability from cvelistv5
Published
2024-11-21 03:26
Modified
2024-11-21 17:54
Summary
Possible information exposure through log file vulnerability where sensitive fields are recorded in the debug-enabled logs when debugging is turned on in Brocade SANnav before 2.3.0 and 2.2.2a
Impacted products
Vendor Product Version
Brocade SANnav Version: Brocade SANnav before v2.3.0 and 2.2.2a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-11-21T04:03:36.486Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://security.netapp.com/advisory/ntap-20240229-0005/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43937",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T17:54:03.897768Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T17:54:10.574Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade SANnav before v2.3.0 and 2.2.2a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003ePossible information exposure through log file vulnerability where sensitive fields are recorded in the debug-enabled logs when debugging is turned on in Brocade SANnav before 2.3.0 and 2.2.2a\u003c/p\u003e\u003cbr\u003e"
            }
          ],
          "value": "Possible information exposure through log file vulnerability where sensitive fields are recorded in the debug-enabled logs when debugging is turned on in Brocade SANnav before 2.3.0 and 2.2.2a"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37: Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-21T03:26:58.406Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22509"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Brocade SANnav Information Disclosure Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2022-43937",
    "datePublished": "2024-11-21T03:26:58.406Z",
    "dateReserved": "2022-10-26T19:34:16.362Z",
    "dateUpdated": "2024-11-21T17:54:10.574Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-43934
Vulnerability from cvelistv5
Published
2024-11-21 01:43
Modified
2024-11-21 18:01
Summary
Brocade SANnav before Brocade SANnav 2.2.2 supports key exchange algorithms, which are considered weak on ports 24, 6514, 18023, 19094, and 19095.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43934",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T17:55:48.685463Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T18:01:26.337Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "unaffected",
              "version": "Brocade SANnav 2.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eBrocade SANnav before Brocade SANnav 2.2.2 supports key exchange algorithms, which are considered weak on ports 24, 6514, 18023, 19094, and 19095.\u003c/p\u003e\u003cbr\u003e"
            }
          ],
          "value": "Brocade SANnav before Brocade SANnav 2.2.2 supports key exchange algorithms, which are considered weak on ports 24, 6514, 18023, 19094, and 19095."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-97",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-97 Cryptanalysis"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327 Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-21T01:43:54.749Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/21220"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Weak Key-exchange algorithms",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2022-43934",
    "datePublished": "2024-11-21T01:43:54.749Z",
    "dateReserved": "2022-10-26T19:34:16.360Z",
    "dateUpdated": "2024-11-21T18:01:26.337Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-33187
Vulnerability from cvelistv5
Published
2022-12-09 01:48
Modified
2024-08-03 08:01
Summary
Brocade SANnav before v2.2.1 logs usernames and encoded passwords in debug-enabled logs. The vulnerability could allow an attacker with admin privilege to read sensitive information.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: Brocade SANnav versions before v2.2.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:01:20.304Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2022-2122"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade SANnav versions before v2.2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\nBrocade SANnav before v2.2.1 logs usernames and encoded passwords in \ndebug-enabled logs. The vulnerability could allow an attacker with admin\n privilege to read sensitive information.\n\n"
            }
          ],
          "value": "Brocade SANnav before v2.2.1 logs usernames and encoded passwords in \ndebug-enabled logs. The vulnerability could allow an attacker with admin\n privilege to read sensitive information.\n\n"
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Insertion of Sensitive Information into Log File"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-09T01:48:24.949Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2022-2122"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Brocade SANnav before v2.2.1 logs usernames and encoded passwords in debug-enabled logs",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2022-33187",
    "datePublished": "2022-12-09T01:48:24.949Z",
    "dateReserved": "2022-06-13T17:49:51.966Z",
    "dateUpdated": "2024-08-03T08:01:20.304Z",
    "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29962
Vulnerability from cvelistv5
Published
2024-04-19 04:15
Modified
2024-08-02 01:17
Summary
Brocade SANnav OVA before v2.3.1 and v2.3.0a have an insecure file permission setting that makes files world-readable. This could allow a local user without the required privileges to access sensitive information or a Java binary.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1, and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29962",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T16:04:21.724986Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:57:13.364Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.555Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23248"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1, and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Brocade SANnav OVA before v2.3.1 and v2.3.0a have an insecure file permission setting that makes files world-readable. This could allow a local user without the required privileges to access sensitive information or a Java binary.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "Brocade SANnav OVA before v2.3.1 and v2.3.0a have an insecure file permission setting that makes files world-readable. This could allow a local user without the required privileges to access sensitive information or a Java binary.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276 Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-19T04:15:43.213Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23248"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insecure file permission setting that makes files world-readable",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29962",
    "datePublished": "2024-04-19T04:15:43.213Z",
    "dateReserved": "2024-03-22T05:23:33.322Z",
    "dateUpdated": "2024-08-02T01:17:58.555Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-16205
Vulnerability from cvelistv5
Published
2019-11-08 17:17
Modified
2024-08-05 01:10
Severity ?
Summary
A vulnerability, in Brocade SANnav versions before v2.0, could allow remote attackers to brute-force a valid session ID. The vulnerability is due to an insufficiently random session ID for several post-authentication actions in the SANnav portal.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:10:41.612Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-864"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Brocade SANnav",
          "vendor": "Brocade Communications Systems, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "versions before v2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, in Brocade SANnav versions before v2.0, could allow remote attackers to brute-force a valid session ID. The vulnerability is due to an insufficiently random session ID for several post-authentication actions in the SANnav portal."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information exposure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-08T17:20:08",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-864"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@brocade.com",
          "ID": "CVE-2019-16205",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Brocade SANnav",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions before v2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Brocade Communications Systems, Inc."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability, in Brocade SANnav versions before v2.0, could allow remote attackers to brute-force a valid session ID. The vulnerability is due to an insufficiently random session ID for several post-authentication actions in the SANnav portal."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Information exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-864",
              "refsource": "CONFIRM",
              "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-864"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2019-16205",
    "datePublished": "2019-11-08T17:17:16",
    "dateReserved": "2019-09-10T00:00:00",
    "dateUpdated": "2024-08-05T01:10:41.612Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29958
Vulnerability from cvelistv5
Published
2024-04-19 03:15
Modified
2024-08-02 01:17
Summary
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints the encryption key in the console when a privileged user executes the script to replace the Brocade SANnav Management Portal standby node. This could provide attackers an additional, less protected path to acquiring the encryption key.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1 and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29958",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-19T13:41:46.332533Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:57:08.552Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.622Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23242"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1 and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints the encryption key in the console when a privileged user executes the script to replace the Brocade SANnav Management Portal standby node. This could provide attackers an additional, less protected path to acquiring the encryption key.\u003cbr\u003e"
            }
          ],
          "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints the encryption key in the console when a privileged user executes the script to replace the Brocade SANnav Management Portal standby node. This could provide attackers an additional, less protected path to acquiring the encryption key.\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-19T03:15:32.394Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23242"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Encryption key in the console when a privileged user executes the script to replace the Brocade SANnav Management Portal standby node.",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29958",
    "datePublished": "2024-04-19T03:15:32.394Z",
    "dateReserved": "2024-03-22T05:18:44.193Z",
    "dateUpdated": "2024-08-02T01:17:58.622Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29950
Vulnerability from cvelistv5
Published
2024-04-17 18:21
Modified
2024-08-02 01:17
Summary
The class FileTransfer implemented in Brocade SANnav before v2.3.1, v2.3.0a, uses the ssh-rsa signature scheme, which has a SHA-1 hash. The vulnerability could allow a remote, unauthenticated attacker to perform a man-in-the-middle attack.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: versions before Brocade SANnav v2.3.1, v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "affected",
            "product": "brocade_sannav",
            "vendor": "broadcom",
            "versions": [
              {
                "lessThan": "2.3.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:broadcom:brocade_sannav:2.3.0a:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "affected",
            "product": "brocade_sannav",
            "vendor": "broadcom",
            "versions": [
              {
                "status": "affected",
                "version": "2.3.0a"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29950",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-07T20:50:37.864155Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-24T19:35:59.797Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.630Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23236"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "versions before Brocade SANnav v2.3.1, v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The class FileTransfer implemented in Brocade SANnav before v2.3.1, v2.3.0a, uses the ssh-rsa signature scheme, which has a SHA-1 hash.\u003cbr\u003eThe vulnerability could allow a remote, unauthenticated attacker to perform a man-in-the-middle attack.\u003cbr\u003e"
            }
          ],
          "value": "The class FileTransfer implemented in Brocade SANnav before v2.3.1, v2.3.0a, uses the ssh-rsa signature scheme, which has a SHA-1 hash.\nThe vulnerability could allow a remote, unauthenticated attacker to perform a man-in-the-middle attack.\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-217",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-217 Exploiting Incorrectly Configured SSL"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326 Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-17T18:27:18.089Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23236"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Brocade SANnav before v2.3.1, v2.3.0a uses weak encryption",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29950",
    "datePublished": "2024-04-17T18:21:35.720Z",
    "dateReserved": "2024-03-22T05:00:09.537Z",
    "dateUpdated": "2024-08-02T01:17:58.630Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-16209
Vulnerability from cvelistv5
Published
2019-11-08 17:19
Modified
2024-08-05 01:10
Severity ?
Summary
A vulnerability, in The ReportsTrustManager class of Brocade SANnav versions before v2.0, could allow an attacker to perform a man-in-the-middle attack against Secure Sockets Layer(SSL)connections.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:10:41.681Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-868"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Brocade SANnav",
          "vendor": "Brocade Communications Systems, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "versions before v2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, in The ReportsTrustManager class of Brocade SANnav versions before v2.0, could allow an attacker to perform a man-in-the-middle attack against Secure Sockets Layer(SSL)connections."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper Certificate Validation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-08T17:19:12",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-868"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@brocade.com",
          "ID": "CVE-2019-16209",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Brocade SANnav",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions before v2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Brocade Communications Systems, Inc."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability, in The ReportsTrustManager class of Brocade SANnav versions before v2.0, could allow an attacker to perform a man-in-the-middle attack against Secure Sockets Layer(SSL)connections."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Certificate Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-868",
              "refsource": "CONFIRM",
              "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-868"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2019-16209",
    "datePublished": "2019-11-08T17:19:12",
    "dateReserved": "2019-09-10T00:00:00",
    "dateUpdated": "2024-08-05T01:10:41.681Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-43935
Vulnerability from cvelistv5
Published
2024-11-21 01:51
Modified
2024-11-21 18:01
Summary
An information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where Brocade Fabric OS Switch passwords and authorization IDs are printed in the embedded MLS DB file.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43935",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T17:55:52.817993Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T18:01:26.445Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "unaffected",
              "version": "before Brocade SANnav 2.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAn information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where Brocade Fabric OS Switch passwords and authorization IDs are printed in the embedded MLS DB file.\u003c/p\u003e\u003cbr\u003e"
            }
          ],
          "value": "An information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where Brocade Fabric OS Switch passwords and authorization IDs are printed in the embedded MLS DB file."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-21T01:51:59.741Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/21219"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Switch passwords and authorization IDs are printed in the embedded MLS DB file",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2022-43935",
    "datePublished": "2024-11-21T01:51:59.741Z",
    "dateReserved": "2022-10-26T19:34:16.361Z",
    "dateUpdated": "2024-11-21T18:01:26.445Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-4173
Vulnerability from cvelistv5
Published
2024-04-25 07:30
Modified
2024-08-01 20:33
Summary
A vulnerability in Brocade SANnav exposes Kafka in the wan interface. The vulnerability could allow an unauthenticated attacker to perform various attacks, including DOS against the Brocade SANnav.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: All Versions
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4173",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-26T16:08:55.700879Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:56:13.872Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.534Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23285"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eA vulnerability in Brocade SANnav exposes Kafka in the wan interface.\u003c/p\u003e\u003cp\u003eThe vulnerability could allow an unauthenticated attacker to perform various attacks, including DOS against the Brocade SANnav.\u003c/p\u003e\n\n\u003cp\u003e\u003c/p\u003e\n\n"
            }
          ],
          "value": "\nA vulnerability in Brocade SANnav exposes Kafka in the wan interface.\n\nThe vulnerability could allow an unauthenticated attacker to perform various attacks, including DOS against the Brocade SANnav.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-1",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-25T22:40:28.343Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23285"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "SANnav versions exposes Kafka in the wan interface.",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-4173",
    "datePublished": "2024-04-25T07:30:44.685Z",
    "dateReserved": "2024-04-25T07:07:22.074Z",
    "dateUpdated": "2024-08-01T20:33:52.534Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29957
Vulnerability from cvelistv5
Published
2024-04-19 03:11
Modified
2024-08-02 01:17
Summary
When Brocade SANnav before v2.3.1 and v2.3.0a servers are configured in Disaster Recovery mode, the encryption key is stored in the DR log files. This could provide attackers with an additional, less-protected path to acquiring the encryption key.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1 and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29957",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-19T18:28:36.735173Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:57:45.044Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.659Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23241"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1 and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "When Brocade SANnav before v2.3.1 and v2.3.0a servers are configured in Disaster Recovery mode, the encryption key is stored in the DR log files. This could provide attackers with an additional, less-protected path to acquiring the encryption key.\u003cbr\u003e"
            }
          ],
          "value": "When Brocade SANnav before v2.3.1 and v2.3.0a servers are configured in Disaster Recovery mode, the encryption key is stored in the DR log files. This could provide attackers with an additional, less-protected path to acquiring the encryption key.\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-19T03:11:25.892Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23241"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Encryption key is stored in the DR log files",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29957",
    "datePublished": "2024-04-19T03:11:25.892Z",
    "dateReserved": "2024-03-22T05:18:44.193Z",
    "dateUpdated": "2024-08-02T01:17:58.659Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29967
Vulnerability from cvelistv5
Published
2024-04-19 05:06
Modified
2024-08-02 01:17
Summary
In Brocade SANnav before Brocade SANnav v2.31 and v2.3.0a, it was observed that Docker instances inside the appliance have insecure mount points, allowing reading and writing access to sensitive files. The vulnerability could allow a sudo privileged user on the host OS to read and write access to these files.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before Brocade SANnav v2.31 and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "2.3.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29967",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-19T13:35:00.798238Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:58:11.457Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.699Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23254"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": " before Brocade SANnav v2.31 and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In Brocade SANnav before Brocade SANnav v2.31 and v2.3.0a, it was observed that Docker instances inside the appliance have insecure mount points, allowing reading and writing access to sensitive files. The vulnerability could allow a sudo privileged user on the host OS to read and write access to these files. \u003cbr\u003e\n\n"
            }
          ],
          "value": "In Brocade SANnav before Brocade SANnav v2.31 and v2.3.0a, it was observed that Docker instances inside the appliance have insecure mount points, allowing reading and writing access to sensitive files. The vulnerability could allow a sudo privileged user on the host OS to read and write access to these files. \n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276 Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-19T05:06:45.286Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23254"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "In Brocade SANnav before v2.31 and v2.3.0a, it was observed that Docker instances inside the appliance have insecure mount points",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29967",
    "datePublished": "2024-04-19T05:06:45.286Z",
    "dateReserved": "2024-03-22T05:32:26.687Z",
    "dateUpdated": "2024-08-02T01:17:58.699Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-16210
Vulnerability from cvelistv5
Published
2019-11-08 17:05
Modified
2024-08-05 01:10
Severity ?
Summary
Brocade SANnav versions before v2.0, logs plain text database connection password while triggering support save.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:10:41.471Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-869"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Brocade SANnav",
          "vendor": "Brocade Communications Systems, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "versions before v2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Brocade SANnav versions before v2.0, logs plain text database connection password while triggering support save."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information Exposure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-08T17:05:38",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-869"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@brocade.com",
          "ID": "CVE-2019-16210",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Brocade SANnav",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions before v2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Brocade Communications Systems, Inc."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Brocade SANnav versions before v2.0, logs plain text database connection password while triggering support save."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-869",
              "refsource": "CONFIRM",
              "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-869"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2019-16210",
    "datePublished": "2019-11-08T17:05:38",
    "dateReserved": "2019-09-10T00:00:00",
    "dateUpdated": "2024-08-05T01:10:41.471Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-15379
Vulnerability from cvelistv5
Published
2021-06-09 15:15
Modified
2024-08-04 13:15
Severity ?
Summary
Brocade SANnav before v.2.1.0a could allow remote attackers cause a denial-of-service condition due to a lack of proper validation, of the length of user-supplied data as name for custom field name.
Impacted products
Vendor Product Version
n/a Brocade SANnav Version: Brocade SANnav before v.2.1.0a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T13:15:20.150Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1319"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Brocade SANnav",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade SANnav before v.2.1.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Brocade SANnav before v.2.1.0a could allow remote attackers cause a denial-of-service condition due to a lack of proper validation, of the length of user-supplied data as name for custom field name."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Denial of Service",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-09T15:15:19",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1319"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@brocade.com",
          "ID": "CVE-2020-15379",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Brocade SANnav",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Brocade SANnav before v.2.1.0a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Brocade SANnav before v.2.1.0a could allow remote attackers cause a denial-of-service condition due to a lack of proper validation, of the length of user-supplied data as name for custom field name."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Denial of Service"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1319",
              "refsource": "MISC",
              "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1319"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2020-15379",
    "datePublished": "2021-06-09T15:15:19",
    "dateReserved": "2020-06-29T00:00:00",
    "dateUpdated": "2024-08-04T13:15:20.150Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-2860
Vulnerability from cvelistv5
Published
2024-05-08 01:01
Modified
2024-08-01 19:25
Summary
The PostgreSQL implementation in Brocade SANnav versions before 2.3.0a is vulnerable to an incorrect local authentication flaw. An attacker accessing the VM where the Brocade SANnav is installed can gain access to sensitive data inside the PostgreSQL database.
Impacted products
Vendor Product Version
Brocade Brocade SAnnav Version: before SANnav v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2860",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-08T15:12:15.827191Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:29:17.299Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.147Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/24260"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Brocade SAnnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before SANnav v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The PostgreSQL implementation in Brocade SANnav versions before 2.3.0a is vulnerable to an incorrect local authentication flaw. An attacker accessing the VM where the Brocade SANnav is installed can gain access to sensitive data inside the PostgreSQL database.\u003cbr\u003e "
            }
          ],
          "value": "The PostgreSQL implementation in Brocade SANnav versions before 2.3.0a is vulnerable to an incorrect local authentication flaw. An attacker accessing the VM where the Brocade SANnav is installed can gain access to sensitive data inside the PostgreSQL database.\n "
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-08T01:01:54.775Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/24260"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-2860",
    "datePublished": "2024-05-08T01:01:54.775Z",
    "dateReserved": "2024-03-24T01:29:52.208Z",
    "dateUpdated": "2024-08-01T19:25:42.147Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29964
Vulnerability from cvelistv5
Published
2024-04-19 04:39
Modified
2024-09-18 22:30
Summary
Brocade SANnav versions before v2.3.0a do not correctly set permissions on files, including docker files. An unprivileged attacker who gains access to the server can read sensitive information from these files.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29964",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-19T14:25:49.281464Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:56:52.541Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.641Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23249"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u0026nbsp;Brocade SANnav versions before v2.3.0a do not correctly set permissions on files, including docker files. An unprivileged attacker who gains access to the server can read sensitive information from these files.\u003cbr\u003e"
            }
          ],
          "value": "Brocade SANnav versions before v2.3.0a do not correctly set permissions on files, including docker files. An unprivileged attacker who gains access to the server can read sensitive information from these files."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-18T22:30:38.120Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23249"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Brocade SANnav versions before v2.3.0a do not correctly set permissions on files, including docker files",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29964",
    "datePublished": "2024-04-19T04:39:17.273Z",
    "dateReserved": "2024-03-22T05:23:33.322Z",
    "dateUpdated": "2024-09-18T22:30:38.120Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-4159
Vulnerability from cvelistv5
Published
2024-04-25 01:58
Modified
2024-08-01 20:33
Summary
Brocade SANnav before v2.3.0a lacks protection mechanisms on port 2377/TCP and 7946/TCP, which could allow an unauthenticated attacker to sniff the SANnav Docker information.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4159",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-24T17:35:05.585958Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-26T15:51:31.022Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.913Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23282"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003e\n\n\u003c/p\u003e\u003cp\u003eBrocade SANnav before v2.3.0a lacks protection mechanisms on port 2377/TCP and 7946/TCP, which could allow an unauthenticated attacker to sniff the SANnav Docker information.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\n\n"
            }
          ],
          "value": "\nBrocade SANnav before v2.3.0a lacks protection mechanisms on port 2377/TCP and 7946/TCP, which could allow an unauthenticated attacker to sniff the SANnav Docker information.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-1",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-25T22:41:24.054Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23282"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Protection mechanisms",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-4159",
    "datePublished": "2024-04-25T01:58:17.489Z",
    "dateReserved": "2024-04-25T00:17:29.921Z",
    "dateUpdated": "2024-08-01T20:33:52.913Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-23302
Vulnerability from cvelistv5
Published
2022-01-18 15:25
Modified
2024-08-03 03:36
Severity ?
Summary
JMSSink in all versions of Log4j 1.x is vulnerable to deserialization of untrusted data when the attacker has write access to the Log4j configuration or if the configuration references an LDAP service the attacker has access to. The attacker can provide a TopicConnectionFactoryBindingName configuration causing JMSSink to perform JNDI requests that result in remote code execution in a similar fashion to CVE-2021-4104. Note this issue only affects Log4j 1.x when specifically configured to use JMSSink, which is not the default. Apache Log4j 1.2 reached end of life in August 2015. Users should upgrade to Log4j 2 as it addresses numerous other issues from the previous versions.
Impacted products
Vendor Product Version
Apache Software Foundation Apache Log4j 1.x Version: 1.0.1   < unspecified
Version: unspecified   < 2.0-alpha1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:36:20.336Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://lists.apache.org/thread/bsr3l5qz4g0myrjhy9h67bcxodpkwj4w"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://logging.apache.org/log4j/1.2/index.html"
          },
          {
            "name": "[oss-security] 20220118 CVE-2022-23302: Deserialization of untrusted data in JMSSink in Apache Log4j 1.x",
            "tags": [
              "mailing-list",
              "x_refsource_MLIST",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2022/01/18/3"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20220217-0006/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Apache Log4j 1.x",
          "vendor": "Apache Software Foundation",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "1.0.1",
              "versionType": "custom"
            },
            {
              "lessThan": "2.0-alpha1",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Eduardo\u0027 Vela, Maksim Shudrak and Jacob Butler from Google."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "JMSSink in all versions of Log4j 1.x is vulnerable to deserialization of untrusted data when the attacker has write access to the Log4j configuration or if the configuration references an LDAP service the attacker has access to. The attacker can provide a TopicConnectionFactoryBindingName configuration causing JMSSink to perform JNDI requests that result in remote code execution in a similar fashion to CVE-2021-4104. Note this issue only affects Log4j 1.x when specifically configured to use JMSSink, which is not the default. Apache Log4j 1.2 reached end of life in August 2015. Users should upgrade to Log4j 2 as it addresses numerous other issues from the previous versions."
        }
      ],
      "metrics": [
        {
          "other": {
            "content": {
              "other": "high"
            },
            "type": "unknown"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-502",
              "description": "CWE-502 Deserialization of Untrusted Data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-25T16:49:03",
        "orgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
        "shortName": "apache"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://lists.apache.org/thread/bsr3l5qz4g0myrjhy9h67bcxodpkwj4w"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://logging.apache.org/log4j/1.2/index.html"
        },
        {
          "name": "[oss-security] 20220118 CVE-2022-23302: Deserialization of untrusted data in JMSSink in Apache Log4j 1.x",
          "tags": [
            "mailing-list",
            "x_refsource_MLIST"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2022/01/18/3"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220217-0006/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Deserialization of untrusted data in JMSSink in Apache Log4j 1.x",
      "workarounds": [
        {
          "lang": "en",
          "value": "Users should upgrade to Log4j 2 or remove usage of the JMSSink from their configurations."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@apache.org",
          "ID": "CVE-2022-23302",
          "STATE": "PUBLIC",
          "TITLE": "Deserialization of untrusted data in JMSSink in Apache Log4j 1.x"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Apache Log4j 1.x",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003e=",
                            "version_value": "1.0.1"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_value": "2.0-alpha1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Apache Software Foundation"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Eduardo\u0027 Vela, Maksim Shudrak and Jacob Butler from Google."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "JMSSink in all versions of Log4j 1.x is vulnerable to deserialization of untrusted data when the attacker has write access to the Log4j configuration or if the configuration references an LDAP service the attacker has access to. The attacker can provide a TopicConnectionFactoryBindingName configuration causing JMSSink to perform JNDI requests that result in remote code execution in a similar fashion to CVE-2021-4104. Note this issue only affects Log4j 1.x when specifically configured to use JMSSink, which is not the default. Apache Log4j 1.2 reached end of life in August 2015. Users should upgrade to Log4j 2 as it addresses numerous other issues from the previous versions."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": [
          {
            "other": "high"
          }
        ],
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-502 Deserialization of Untrusted Data"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://lists.apache.org/thread/bsr3l5qz4g0myrjhy9h67bcxodpkwj4w",
              "refsource": "MISC",
              "url": "https://lists.apache.org/thread/bsr3l5qz4g0myrjhy9h67bcxodpkwj4w"
            },
            {
              "name": "https://logging.apache.org/log4j/1.2/index.html",
              "refsource": "MISC",
              "url": "https://logging.apache.org/log4j/1.2/index.html"
            },
            {
              "name": "[oss-security] 20220118 CVE-2022-23302: Deserialization of untrusted data in JMSSink in Apache Log4j 1.x",
              "refsource": "MLIST",
              "url": "http://www.openwall.com/lists/oss-security/2022/01/18/3"
            },
            {
              "name": "https://www.oracle.com/security-alerts/cpuapr2022.html",
              "refsource": "MISC",
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20220217-0006/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20220217-0006/"
            },
            {
              "name": "https://www.oracle.com/security-alerts/cpujul2022.html",
              "refsource": "MISC",
              "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Users should upgrade to Log4j 2 or remove usage of the JMSSink from their configurations."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
    "assignerShortName": "apache",
    "cveId": "CVE-2022-23302",
    "datePublished": "2022-01-18T15:25:20",
    "dateReserved": "2022-01-16T00:00:00",
    "dateUpdated": "2024-08-03T03:36:20.336Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-16212
Vulnerability from cvelistv5
Published
2020-09-25 13:07
Modified
2024-08-05 01:10
Severity ?
Summary
A vulnerability in Brocade SANnav versions before v2.1.0 could allow a remote authenticated attacker to conduct an LDAP injection. The vulnerability could allow a remote attacker to bypass the authentication process.
Impacted products
Vendor Product Version
n/a Brocade SANnav Version: Brocade SANnav versions before v2.1.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:10:41.414Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2020-1074"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Brocade SANnav",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade SANnav versions before v2.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in Brocade SANnav versions before v2.1.0 could allow a remote authenticated attacker to conduct an LDAP injection. The vulnerability could allow a remote attacker to bypass the authentication process."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "LDAP injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-09-25T13:07:20",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2020-1074"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@brocade.com",
          "ID": "CVE-2019-16212",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Brocade SANnav",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Brocade SANnav versions before v2.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in Brocade SANnav versions before v2.1.0 could allow a remote authenticated attacker to conduct an LDAP injection. The vulnerability could allow a remote attacker to bypass the authentication process."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "LDAP injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2020-1074",
              "refsource": "MISC",
              "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2020-1074"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2019-16212",
    "datePublished": "2020-09-25T13:07:20",
    "dateReserved": "2019-09-10T00:00:00",
    "dateUpdated": "2024-08-05T01:10:41.414Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-4161
Vulnerability from cvelistv5
Published
2024-04-25 02:32
Modified
2024-08-01 20:33
Summary
In Brocade SANnav, before Brocade SANnav v2.3.0, syslog traffic received clear text. This could allow an unauthenticated, remote attacker to capture sensitive information.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "brocade_sannav",
            "vendor": "broadcom",
            "versions": [
              {
                "lessThan": "2.3.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4161",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-24T19:30:58.455217Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-24T19:41:12.289Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.517Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23284"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\nIn Brocade SANnav, before Brocade SANnav v2.3.0, syslog traffic received\n clear text. This could allow an unauthenticated, remote attacker to \ncapture sensitive information.\n\n"
            }
          ],
          "value": "In Brocade SANnav, before Brocade SANnav v2.3.0, syslog traffic received\n clear text. This could allow an unauthenticated, remote attacker to \ncapture sensitive information.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-117",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-117 Interception"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-25T02:32:08.686Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23284"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Syslog traffic sent in clear-text",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-4161",
    "datePublished": "2024-04-25T02:32:08.686Z",
    "dateReserved": "2024-04-25T02:14:23.617Z",
    "dateUpdated": "2024-08-01T20:33:52.517Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29961
Vulnerability from cvelistv5
Published
2024-04-19 03:59
Modified
2024-08-02 01:17
Summary
A vulnerability affects Brocade SANnav before v2.3.1 and v2.3.0a. It allows a Brocade SANnav service to send ping commands in the background at regular intervals to gridgain.com to check if updates are available for the Component. This could make an unauthenticated, remote attacker aware of the behavior and launch a supply-chain attack against a Brocade SANnav appliance.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1 and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "2.3.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29961",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-19T14:26:52.404607Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:57:54.040Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.481Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23246"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1 and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability affects Brocade SANnav before v2.3.1 and v2.3.0a. It allows a Brocade SANnav service to send ping commands in the background at regular intervals to gridgain.com to check if updates are available for the Component. This could make an unauthenticated, remote attacker aware of the behavior and launch a supply-chain attack against a Brocade SANnav appliance.\u003cbr\u003e"
            }
          ],
          "value": "A vulnerability affects Brocade SANnav before v2.3.1 and v2.3.0a. It allows a Brocade SANnav service to send ping commands in the background at regular intervals to gridgain.com to check if updates are available for the Component. This could make an unauthenticated, remote attacker aware of the behavior and launch a supply-chain attack against a Brocade SANnav appliance.\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-94",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-94 Man in the Middle Attack"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-19T03:59:25.379Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23246"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "supply-chain attack risk",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29961",
    "datePublished": "2024-04-19T03:59:25.379Z",
    "dateReserved": "2024-03-22T05:23:33.322Z",
    "dateUpdated": "2024-08-02T01:17:58.481Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-16208
Vulnerability from cvelistv5
Published
2019-11-08 17:03
Modified
2024-08-05 01:10
Severity ?
Summary
Password-based encryption (PBE) algorithm, of Brocade SANnav versions before v2.0, has a weakness in generating cryptographic keys that may allow an attacker to decrypt passwords used with several services (Radius, TACAS, etc.).
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:10:41.542Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-867"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Brocade SANnav",
          "vendor": "Brocade Communications Systems, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "versions before v2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Password-based encryption (PBE) algorithm, of Brocade SANnav versions before v2.0, has a weakness in generating cryptographic keys that may allow an attacker to decrypt passwords used with several services (Radius, TACAS, etc.)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-08T17:03:39",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-867"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@brocade.com",
          "ID": "CVE-2019-16208",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Brocade SANnav",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions before v2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Brocade Communications Systems, Inc."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Password-based encryption (PBE) algorithm, of Brocade SANnav versions before v2.0, has a weakness in generating cryptographic keys that may allow an attacker to decrypt passwords used with several services (Radius, TACAS, etc.)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Use of a Broken or Risky Cryptographic Algorithm"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-867",
              "refsource": "CONFIRM",
              "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-867"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2019-16208",
    "datePublished": "2019-11-08T17:03:39",
    "dateReserved": "2019-09-10T00:00:00",
    "dateUpdated": "2024-08-05T01:10:41.542Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-43933
Vulnerability from cvelistv5
Published
2024-11-21 01:36
Modified
2024-11-21 18:01
Summary
An information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where configuration secrets are logged in supportsave. Supportsave file is generated by an admin user troubleshooting the switch. The Logged information may include usernames and passwords, and secret keys.
Impacted products
Vendor Product Version
Brocade SANnav Version: before Brocade SANnav 2.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-43933",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T17:55:44.908275Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T18:01:26.215Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before Brocade SANnav 2.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where configuration secrets are logged in supportsave. Supportsave file is generated by an admin user troubleshooting the switch. The Logged information may include usernames and passwords, and secret keys.\u003c/span\u003e"
            }
          ],
          "value": "An information exposure through log file vulnerability exists in Brocade SANnav before Brocade SANnav 2.2.2, where configuration secrets are logged in supportsave. Supportsave file is generated by an admin user troubleshooting the switch. The Logged information may include usernames and passwords, and secret keys."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37: Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-538",
              "description": "CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-21T01:52:42.072Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/21221"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "configuration secrets are logged in support-save",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2022-43933",
    "datePublished": "2024-11-21T01:36:30.175Z",
    "dateReserved": "2022-10-26T19:34:16.360Z",
    "dateUpdated": "2024-11-21T18:01:26.215Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-15382
Vulnerability from cvelistv5
Published
2021-06-09 14:32
Modified
2024-08-04 13:15
Severity ?
Summary
Brocade SANnav before version 2.1.1 uses a hard-coded administrator account with the weak password ‘passw0rd’ if a password is not provided for PostgreSQL at install-time.
Impacted products
Vendor Product Version
n/a Brocade SANnav Version: Brocade SANnav before version 2.1.1
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T13:15:20.697Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1484"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Brocade SANnav",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade SANnav before version 2.1.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Brocade SANnav before version 2.1.1 uses a hard-coded administrator account with the weak password \u2018passw0rd\u2019 if a password is not provided for PostgreSQL at install-time."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Hard-coding credentials",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-09T14:32:23",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1484"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@brocade.com",
          "ID": "CVE-2020-15382",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Brocade SANnav",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Brocade SANnav before version 2.1.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Brocade SANnav before version 2.1.1 uses a hard-coded administrator account with the weak password \u2018passw0rd\u2019 if a password is not provided for PostgreSQL at install-time."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Hard-coding credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1484",
              "refsource": "MISC",
              "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1484"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2020-15382",
    "datePublished": "2021-06-09T14:32:23",
    "dateReserved": "2020-06-29T00:00:00",
    "dateUpdated": "2024-08-04T13:15:20.697Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29956
Vulnerability from cvelistv5
Published
2024-04-18 01:00
Modified
2024-08-02 01:17
Summary
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints the Brocade SANnav password in clear text in supportsave logs when a user schedules a switch Supportsave from Brocade SANnav.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1 and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "affected",
            "product": "brocade_sannav",
            "vendor": "broadcom",
            "versions": [
              {
                "lessThan": "v2.3.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "v2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29956",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-06T19:20:36.709139Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-24T19:36:47.794Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.555Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23240"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1 and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints the Brocade SANnav password in clear text in supportsave logs when a user schedules a switch Supportsave from Brocade SANnav.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a prints the Brocade SANnav password in clear text in supportsave logs when a user schedules a switch Supportsave from Brocade SANnav.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": " CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-18T01:00:49.444Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23240"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "cleartext password in supportsave logs when a user schedules a switch Supportsave from Brocade SANnav",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29956",
    "datePublished": "2024-04-18T01:00:49.444Z",
    "dateReserved": "2024-03-22T05:18:44.192Z",
    "dateUpdated": "2024-08-02T01:17:58.555Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-16207
Vulnerability from cvelistv5
Published
2019-11-08 17:02
Modified
2024-08-05 01:10
Severity ?
Summary
Brocade SANnav versions before v2.0 use a hard-coded password, which could allow local authenticated attackers to access a back-end database and gain privileges.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:10:41.592Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-866"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Brocade SANnav",
          "vendor": "Brocade Communications Systems, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "versions before v2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Brocade SANnav versions before v2.0 use a hard-coded password, which could allow local authenticated attackers to access a back-end database and gain privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Use of Hard-coded Credentials",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-08T17:02:32",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-866"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@brocade.com",
          "ID": "CVE-2019-16207",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Brocade SANnav",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions before v2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Brocade Communications Systems, Inc."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Brocade SANnav versions before v2.0 use a hard-coded password, which could allow local authenticated attackers to access a back-end database and gain privileges."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-866",
              "refsource": "CONFIRM",
              "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2019-866"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2019-16207",
    "datePublished": "2019-11-08T17:02:32",
    "dateReserved": "2019-09-10T00:00:00",
    "dateUpdated": "2024-08-05T01:10:41.592Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31423
Vulnerability from cvelistv5
Published
2023-08-31 00:43
Modified
2025-02-13 16:50
Summary
Possible information exposure through log file vulnerability where sensitive fields are recorded in the configuration log without masking on Brocade SANnav before v2.3.0 and 2.2.2a. Notes: To access the logs, the local attacker must have access to an already collected Brocade SANnav "supportsave" outputs.
Impacted products
Vendor Product Version
Brocade SANnav Version: Brocade SANnav before v2.3.0 and 2.2.2a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:53:31.085Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22508"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20240229-0003/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31423",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-27T13:08:50.404003Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-27T14:24:13.370Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade SANnav before v2.3.0 and 2.2.2a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Possible\n information exposure through log file vulnerability where sensitive \nfields are recorded in the configuration log without masking on Brocade \nSANnav before v2.3.0 and 2.2.2a. Notes:\n To access the logs, the local attacker must have access to an already collected Brocade SANnav \"supportsave\" \noutputs."
            }
          ],
          "value": "Possible\n information exposure through log file vulnerability where sensitive \nfields are recorded in the configuration log without masking on Brocade \nSANnav before v2.3.0 and 2.2.2a. Notes:\n To access the logs, the local attacker must have access to an already collected Brocade SANnav \"supportsave\" \noutputs."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-29T21:05:58.934Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22508"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20240229-0003/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Possible information exposure through log file vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-31423",
    "datePublished": "2023-08-31T00:43:39.805Z",
    "dateReserved": "2023-04-28T00:14:58.123Z",
    "dateUpdated": "2025-02-13T16:50:08.160Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-31424
Vulnerability from cvelistv5
Published
2023-08-31 00:54
Modified
2025-02-13 16:50
Summary
Brocade SANnav Web interface before Brocade SANnav v2.3.0 and v2.2.2a allows remote unauthenticated users to bypass web authentication and authorization.
Impacted products
Vendor Product Version
Brocade SANnav Version: Brocade SANnav before Brocade SANnav v2.3.0 and v2.2.2a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:53:30.770Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22507"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20240229-0004/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31424",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T18:03:54.856273Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-01T18:04:07.464Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade SANnav before Brocade SANnav v2.3.0 and v2.2.2a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Brocade SANnav Web interface before Brocade SANnav v2.3.0 and v2.2.2a\n allows remote unauthenticated users to bypass web authentication and \nauthorization."
            }
          ],
          "value": "Brocade SANnav Web interface before Brocade SANnav v2.3.0 and v2.2.2a\n allows remote unauthenticated users to bypass web authentication and \nauthorization."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-290",
              "description": "CWE-290 Authentication Bypass by Spoofing",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-29T21:05:57.090Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/22507"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20240229-0004/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Web authentication and authorization bypass",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2023-31424",
    "datePublished": "2023-08-31T00:54:27.046Z",
    "dateReserved": "2023-04-28T00:14:58.124Z",
    "dateUpdated": "2025-02-13T16:50:08.711Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-15387
Vulnerability from cvelistv5
Published
2021-06-09 15:24
Modified
2024-08-04 13:15
Severity ?
Summary
The host SSH servers of Brocade Fabric OS before Brocade Fabric OS v7.4.2h, v8.2.1c, v8.2.2, v9.0.0, and Brocade SANnav before v2.1.1 utilize keys of less than 2048 bits, which may be vulnerable to man-in-the-middle attacks and/or insecure SSH communications.
Impacted products
Vendor Product Version
n/a Brocade SANnav & Brocade Fabric OS Version: Brocade Fabric OS v7.4.2h, v8.2.1c, v8.2.2, v9.0.0 and Brocade SANnav v2.1.1
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T13:15:20.616Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1291"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Brocade SANnav \u0026 Brocade Fabric OS",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade Fabric OS v7.4.2h, v8.2.1c, v8.2.2, v9.0.0 and Brocade SANnav v2.1.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The host SSH servers of Brocade Fabric OS before Brocade Fabric OS v7.4.2h, v8.2.1c, v8.2.2, v9.0.0, and Brocade SANnav before v2.1.1 utilize keys of less than 2048 bits, which may be vulnerable to man-in-the-middle attacks and/or insecure SSH communications."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "information disclosure vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-09T15:24:45",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1291"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@brocade.com",
          "ID": "CVE-2020-15387",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Brocade SANnav \u0026 Brocade Fabric OS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Brocade Fabric OS v7.4.2h, v8.2.1c, v8.2.2, v9.0.0 and Brocade SANnav v2.1.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The host SSH servers of Brocade Fabric OS before Brocade Fabric OS v7.4.2h, v8.2.1c, v8.2.2, v9.0.0, and Brocade SANnav before v2.1.1 utilize keys of less than 2048 bits, which may be vulnerable to man-in-the-middle attacks and/or insecure SSH communications."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "information disclosure vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1291",
              "refsource": "MISC",
              "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1291"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2020-15387",
    "datePublished": "2021-06-09T15:24:45",
    "dateReserved": "2020-06-29T00:00:00",
    "dateUpdated": "2024-08-04T13:15:20.616Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29955
Vulnerability from cvelistv5
Published
2024-04-17 22:11
Modified
2024-08-02 01:17
Summary
A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a could allow a privileged user to print the SANnav encrypted key in PostgreSQL startup logs. This could provide attackers with an additional, less-protected path to acquiring the encryption key.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1 and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "status": "affected",
                "version": "*2.3.1"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29955",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-23T15:46:11.788196Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:57:25.331Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.612Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23239"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1 and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a could allow a privileged user to print the SANnav encrypted key in PostgreSQL startup logs. \u003cbr\u003eThis could provide attackers with an additional, less-protected path to acquiring the encryption key. \u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "A vulnerability in Brocade SANnav before v2.3.1 and v2.3.0a could allow a privileged user to print the SANnav encrypted key in PostgreSQL startup logs. \nThis could provide attackers with an additional, less-protected path to acquiring the encryption key. \n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-215",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-215 Fuzzing and observing application log data/errors for application mapping"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-17T22:42:20.562Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23239"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insertion of Sensitive Information into Brocade SANnav Log File",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29955",
    "datePublished": "2024-04-17T22:11:51.261Z",
    "dateReserved": "2024-03-22T05:18:44.192Z",
    "dateUpdated": "2024-08-02T01:17:58.612Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29960
Vulnerability from cvelistv5
Published
2024-04-19 03:30
Modified
2024-08-02 01:17
Summary
In Brocade SANnav server before v2.3.1 and v2.3.0a, the SSH keys inside the OVA image are identical in the VM every time SANnav is installed. Any Brocade SAnnav VM based on the official OVA images is vulnerable to MITM over SSH. An attacker can decrypt and compromise the SSH traffic to the SANnav.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1 and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29960",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-29T18:34:09.303371Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:57:32.684Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.593Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23244"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1 and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Brocade SANnav server before v2.3.1 and v2.3.0a, the SSH keys inside the OVA image are identical in the VM every time SANnav is installed. Any Brocade SAnnav VM based on the official OVA images is vulnerable to MITM over SSH. An attacker can decrypt and compromise the SSH traffic to the SANnav.\u003c/span\u003e\n\n\u003c/div\u003e"
            }
          ],
          "value": "\nIn Brocade SANnav server before v2.3.1 and v2.3.0a, the SSH keys inside the OVA image are identical in the VM every time SANnav is installed. Any Brocade SAnnav VM based on the official OVA images is vulnerable to MITM over SSH. An attacker can decrypt and compromise the SSH traffic to the SANnav.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-70",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-70 Try Common or Default Usernames and Passwords"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-26T21:57:23.529Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23244"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Identical SSH keys utilized inside the OVA image (CVE-2024-29960)",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29960",
    "datePublished": "2024-04-19T03:30:51.466Z",
    "dateReserved": "2024-03-22T05:23:33.322Z",
    "dateUpdated": "2024-08-02T01:17:58.593Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29966
Vulnerability from cvelistv5
Published
2024-04-19 04:53
Modified
2024-08-02 01:17
Summary
Brocade SANnav OVA before v2.3.1 and v2.3.0a contain hard-coded credentials in the documentation that appear as the appliance's root password. The vulnerability could allow an unauthenticated attacker full access to the Brocade SANnav appliance.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1 and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29966",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-23T19:29:24.695419Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:58:01.762Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.656Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23255"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav ",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1 and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Brocade SANnav OVA before v2.3.1 and v2.3.0a contain hard-coded credentials in the documentation that appear as the appliance\u0027s root password. The vulnerability could allow an unauthenticated attacker full access to the Brocade SANnav appliance.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "Brocade SANnav OVA before v2.3.1 and v2.3.0a contain hard-coded credentials in the documentation that appear as the appliance\u0027s root password. The vulnerability could allow an unauthenticated attacker full access to the Brocade SANnav appliance.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-19T04:53:59.021Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23255"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "hard-coded credentials in the documentation that appear as the appliance root password",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29966",
    "datePublished": "2024-04-19T04:53:59.021Z",
    "dateReserved": "2024-03-22T05:32:26.687Z",
    "dateUpdated": "2024-08-02T01:17:58.656Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-16211
Vulnerability from cvelistv5
Published
2020-09-25 13:08
Modified
2024-08-05 01:10
Severity ?
Summary
Brocade SANnav versions before v2.1.0, contain a Plaintext Password Storage vulnerability.
Impacted products
Vendor Product Version
n/a Brocade SANnav Version: Brocade SANnav versions before v2.1.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:10:41.328Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2020-1076"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Brocade SANnav",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade SANnav versions before v2.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Brocade SANnav versions before v2.1.0, contain a Plaintext Password Storage vulnerability."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Unprotected Storage of Credentials",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-09-25T13:08:13",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2020-1076"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@brocade.com",
          "ID": "CVE-2019-16211",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Brocade SANnav",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Brocade SANnav versions before v2.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Brocade SANnav versions before v2.1.0, contain a Plaintext Password Storage vulnerability."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Unprotected Storage of Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2020-1076",
              "refsource": "MISC",
              "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2020-1076"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2019-16211",
    "datePublished": "2020-09-25T13:08:13",
    "dateReserved": "2019-09-10T00:00:00",
    "dateUpdated": "2024-08-05T01:10:41.328Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2024-29968
Vulnerability from cvelistv5
Published
2024-04-19 05:17
Modified
2024-09-18 22:32
Summary
An information disclosure vulnerability exists in Brocade SANnav before v2.3.1 and v2.3.0a when Brocade SANnav instances are configured in disaster recovery mode. SQL Table names, column names, and SQL queries are collected in DR standby Supportsave. This could allow authenticated users to access the database structure and its contents.
Impacted products
Vendor Product Version
Brocade Brocade SANnav Version: before v2.3.1 and v2.3.0a
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29968",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-19T17:40:47.516019Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:56:46.782Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.610Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23253"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before v2.3.1 and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An information disclosure vulnerability exists in Brocade SANnav before v2.3.1 and v2.3.0a when Brocade SANnav instances are configured in disaster recovery mode. SQL Table names, column names, and SQL queries are collected in DR standby Supportsave. This could allow authenticated users to access the database structure and its contents."
            }
          ],
          "value": "An information disclosure vulnerability exists in Brocade SANnav before v2.3.1 and v2.3.0a when Brocade SANnav instances are configured in disaster recovery mode. SQL Table names, column names, and SQL queries are collected in DR standby Supportsave. This could allow authenticated users to access the database structure and its contents."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-922",
              "description": "CWE-922 Insecure Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-18T22:32:12.764Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23253"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "SQL Table names, column names, and SQL queries are collected in DR standby Supportsave",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29968",
    "datePublished": "2024-04-19T05:17:57.502Z",
    "dateReserved": "2024-03-22T05:32:26.687Z",
    "dateUpdated": "2024-09-18T22:32:12.764Z",
    "state": "PUBLISHED"
  },