Vulnerabilites related to schneider-electric - bmxnoe0110h
cve-2017-6017
Vulnerability from cvelistv5
Published
2017-06-30 02:35
Modified
2024-08-05 15:18
Severity ?
EPSS score ?
Summary
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.
References
▼ | URL | Tags |
---|---|---|
https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/ | x_refsource_CONFIRM | |
http://www.securityfocus.com/bid/96414 | vdb-entry, x_refsource_BID | |
https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Schneider Electric Modicon M340 PLC |
Version: Schneider Electric Modicon M340 PLC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T15:18:49.611Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/" }, { "name": "96414", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/96414" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Schneider Electric Modicon M340 PLC", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Schneider Electric Modicon M340 PLC" } ] } ], "datePublic": "2017-06-29T00:00:00", "descriptions": [ { "lang": "en", "value": "A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-12-24T15:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/" }, { "name": "96414", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/96414" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2017-6017", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Schneider Electric Modicon M340 PLC", "version": { "version_data": [ { "version_value": "Schneider Electric Modicon M340 PLC" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/", "refsource": "CONFIRM", "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/" }, { "name": "96414", "refsource": "BID", "url": "http://www.securityfocus.com/bid/96414" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2017-6017", "datePublished": "2017-06-30T02:35:00", "dateReserved": "2017-02-16T00:00:00", "dateUpdated": "2024-08-05T15:18:49.611Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2015-7937
Vulnerability from cvelistv5
Published
2015-12-21 11:00
Modified
2024-08-06 08:06
Severity ?
EPSS score ?
Summary
Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01 | x_refsource_MISC | |
http://www.securityfocus.com/bid/79622 | vdb-entry, x_refsource_BID | |
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01 | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T08:06:30.903Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01" }, { "name": "79622", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/79622" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2015-12-17T00:00:00", "descriptions": [ { "lang": "en", "value": "Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2016-11-25T19:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01" }, { "name": "79622", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/79622" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2015-7937", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01" }, { "name": "79622", "refsource": "BID", "url": "http://www.securityfocus.com/bid/79622" }, { "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01", "refsource": "CONFIRM", "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2015-7937", "datePublished": "2015-12-21T11:00:00", "dateReserved": "2015-10-22T00:00:00", "dateUpdated": "2024-08-06T08:06:30.903Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2015-6461
Vulnerability from cvelistv5
Published
2019-03-21 18:17
Modified
2024-08-06 07:22
Severity ?
EPSS score ?
Summary
Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Schneider Electric Modicon PLC |
Version: BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T07:22:21.501Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Schneider Electric Modicon PLC", "vendor": "n/a", "versions": [ { "status": "affected", "version": "BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H." } ] } ], "datePublic": "2015-09-03T00:00:00", "descriptions": [ { "lang": "en", "value": "Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-98", "description": "Remote file inclusion CWE-98", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-03-21T18:17:48", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2015-6461", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Schneider Electric Modicon PLC", "version": { "version_data": [ { "version_value": "BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H." } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Remote file inclusion CWE-98" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2015-6461", "datePublished": "2019-03-21T18:17:48", "dateReserved": "2015-08-17T00:00:00", "dateUpdated": "2024-08-06T07:22:21.501Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2015-6462
Vulnerability from cvelistv5
Published
2019-03-21 18:44
Modified
2024-08-06 07:22
Severity ?
EPSS score ?
Summary
Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.
References
▼ | URL | Tags |
---|---|---|
https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Schneider Electric Modicon PLC |
Version: BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T07:22:21.488Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Schneider Electric Modicon PLC", "vendor": "n/a", "versions": [ { "status": "affected", "version": "BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H." } ] } ], "datePublic": "2015-09-03T00:00:00", "descriptions": [ { "lang": "en", "value": "Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "Cross-site scripting CWE-79", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-03-21T18:44:47", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2015-6462", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Schneider Electric Modicon PLC", "version": { "version_data": [ { "version_value": "BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H." } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Cross-site scripting CWE-79" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2015-6462", "datePublished": "2019-03-21T18:44:47", "dateReserved": "2015-08-17T00:00:00", "dateUpdated": "2024-08-06T07:22:21.488Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2015-12-21 11:59
Modified
2024-11-21 02:37
Severity ?
Summary
Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01 | Vendor Advisory | |
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/79622 | ||
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/79622 | ||
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnoc0401:-:*:*:*:*:*:*:*", "matchCriteriaId": "DF08654A-FFCB-47D3-AC82-DF7284548962", "vulnerable": true }, { "criteria": "cpe:2.3:h:schneider-electric:bmxnoe0100:-:*:*:*:*:*:*:*", "matchCriteriaId": "80FC6FF2-D662-4A57-AAA6-BC04351DC779", "vulnerable": true }, { "criteria": "cpe:2.3:h:schneider-electric:bmxnoe0100h:-:*:*:*:*:*:*:*", "matchCriteriaId": "C37C1E3E-CA86-4AB5-82A8-BA758F02475D", "vulnerable": true }, { "criteria": "cpe:2.3:h:schneider-electric:bmxnoe0110:-:*:*:*:*:*:*:*", "matchCriteriaId": "98F3B055-8919-4E09-9827-288F0A03DAFF", "vulnerable": true }, { "criteria": "cpe:2.3:h:schneider-electric:bmxnoe0110h:-:*:*:*:*:*:*:*", "matchCriteriaId": "1E47DB14-EF4B-4E4E-9DA2-B3F6EFA72BF4", "vulnerable": true }, { "criteria": "cpe:2.3:h:schneider-electric:bmxnor0200:-:*:*:*:*:*:*:*", "matchCriteriaId": "ABF43229-1E2E-493A-B44F-DD2870559A93", "vulnerable": true }, { "criteria": "cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*", "matchCriteriaId": "60D9A366-3394-4275-B884-AE6E7227156E", "vulnerable": true }, { "criteria": "cpe:2.3:h:schneider-electric:bmxpra0100:-:*:*:*:*:*:*:*", "matchCriteriaId": "87FE8964-ECA5-4F5C-933D-F527BDDA1316", "vulnerable": true }, { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020:-:*:*:*:*:*:*:*", "matchCriteriaId": "99F2F851-C18F-4CB8-B47C-516F2AC7955D", "vulnerable": true }, { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020h:-:*:*:*:*:*:*:*", "matchCriteriaId": "56BAED8B-EEFA-45D7-A5A3-9B62067CE24C", "vulnerable": true }, { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342030:-:*:*:*:*:*:*:*", "matchCriteriaId": "E472ABB0-5556-4B96-9CEF-2180E24FA7FD", "vulnerable": true }, { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302:-:*:*:*:*:*:*:*", "matchCriteriaId": "354968F7-C41B-4C21-8E47-81DC07DF0EA5", "vulnerable": true }, { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302h:-:*:*:*:*:*:*:*", "matchCriteriaId": "075A16D1-F4DF-4DCB-8DF9-152E282CE01F", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data." }, { "lang": "es", "value": "Desbordamiento de buffer basado en pila en GoAhead Web Server en dispositivos Schneider Electric Modicon M340 PLC BMXNOx y BMXPx permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de una contrase\u00f1a larga en los datos de HTTP Basic Authentication." } ], "id": "CVE-2015-7937", "lastModified": "2024-11-21T02:37:41.870", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2015-12-21T11:59:12.097", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01" }, { "source": "ics-cert@hq.dhs.gov", "url": "http://www.securityfocus.com/bid/79622" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.securityfocus.com/bid/79622" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2017-06-30 03:29
Modified
2024-11-21 03:28
Severity ?
Summary
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/96414 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03 | Mitigation, Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/ | ||
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/96414 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03 | Mitigation, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/ |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnoc0401_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "389C7D02-534F-4FA3-AB3C-B3F39A71900E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnoc0401:-:*:*:*:*:*:*:*", "matchCriteriaId": "DF08654A-FFCB-47D3-AC82-DF7284548962", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnoe0100_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "7BDF7041-ED14-44E4-A6E2-868E2432A2EF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnoe0100:-:*:*:*:*:*:*:*", "matchCriteriaId": "80FC6FF2-D662-4A57-AAA6-BC04351DC779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnoe0110_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "022727EE-C23D-415F-8F61-29C068C0372E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnoe0110:-:*:*:*:*:*:*:*", "matchCriteriaId": "98F3B055-8919-4E09-9827-288F0A03DAFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnoe0110h_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "D5155A17-6C21-43DF-BB7F-B4CACAC25826", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnoe0110h:-:*:*:*:*:*:*:*", "matchCriteriaId": "1E47DB14-EF4B-4E4E-9DA2-B3F6EFA72BF4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnor0200h_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "B0509170-2D6C-4864-841D-30E74A1F4731", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*", "matchCriteriaId": "60D9A366-3394-4275-B884-AE6E7227156E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "146C7F94-4838-4C53-BB73-7E7F05EAE7D9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp341000:-:*:*:*:*:*:*:*", "matchCriteriaId": "178D2338-E48E-493C-992F-337AACE794DE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "393BF977-E478-4396-B9E6-A760C56048BB", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6D150239-27E2-4CBE-A931-5107C15E362F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "D13E4CD0-11DB-4987-A30D-C4D635E35BD2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420102:-:*:*:*:*:*:*:*", "matchCriteriaId": "98212CF5-BCF4-4A55-B62A-484569687B4E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102cl_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "FE26AA5C-40EC-4753-B98C-B6D998630D97", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420102cl:-:*:*:*:*:*:*:*", "matchCriteriaId": "D30336F0-EDCF-486C-B52E-D0C53BCDFC65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "DC7F40A9-1D33-4ECD-BB3E-A34E8702348E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020:-:*:*:*:*:*:*:*", "matchCriteriaId": "99F2F851-C18F-4CB8-B47C-516F2AC7955D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020h_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "7E8A1950-48B2-4F0F-BC59-5BE851510B26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020h:-:*:*:*:*:*:*:*", "matchCriteriaId": "56BAED8B-EEFA-45D7-A5A3-9B62067CE24C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "4E2C68F9-36D3-4509-B33C-5AA2836FF4BB", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342030:-:*:*:*:*:*:*:*", "matchCriteriaId": "E472ABB0-5556-4B96-9CEF-2180E24FA7FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "97B3AFA3-A58C-45DE-93C7-5D015F6A3464", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302:-:*:*:*:*:*:*:*", "matchCriteriaId": "354968F7-C41B-4C21-8E47-81DC07DF0EA5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302h_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "2DEEDCA0-FF8D-4CED-9799-932168043661", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302h:-:*:*:*:*:*:*:*", "matchCriteriaId": "075A16D1-F4DF-4DCB-8DF9-152E282CE01F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030h_firmware:2.8:*:*:*:*:*:*:*", "matchCriteriaId": "2425E29E-39F0-41FC-8C64-77547F6D6790", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342030h:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF9608E7-C9B5-4945-9609-690231DB1B5A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover." }, { "lang": "es", "value": "Se ha descubierto un problema de agotamiento de recursos en Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H y BMXP342030H. Un atacante remoto podr\u00eda enviar un conjunto de paquetes manipulados al PLC para congelarlo, lo que requerir\u00eda que el operador presionase f\u00edsicamente el bot\u00f3n reset en el PLC para recuperarlo." } ], "id": "CVE-2017-6017", "lastModified": "2024-11-21T03:28:54.620", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2017-06-30T03:29:00.233", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/96414" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03" }, { "source": "ics-cert@hq.dhs.gov", "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/96414" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-03-21 19:29
Modified
2024-11-21 02:35
Severity ?
Summary
Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnoc0401_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1769F1F-EAA9-4EE6-9333-A9A4EF4F0F44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnoc0401:-:*:*:*:*:*:*:*", "matchCriteriaId": "DF08654A-FFCB-47D3-AC82-DF7284548962", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnoe0100_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D6712F95-3145-4A61-AF36-F0ECEE961ACD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnoe0100:-:*:*:*:*:*:*:*", "matchCriteriaId": "80FC6FF2-D662-4A57-AAA6-BC04351DC779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnoe0110_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A6E813C6-D9FF-4BEE-969C-FD3C347AE9AF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnoe0110:-:*:*:*:*:*:*:*", "matchCriteriaId": "98F3B055-8919-4E09-9827-288F0A03DAFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnoe0110h_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "7C19F796-5548-45AA-ACED-25D9E640306E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnoe0110h:-:*:*:*:*:*:*:*", "matchCriteriaId": "1E47DB14-EF4B-4E4E-9DA2-B3F6EFA72BF4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnor0200h_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1D0B4021-E058-4B5B-823B-BB1C0A939E30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*", "matchCriteriaId": "60D9A366-3394-4275-B884-AE6E7227156E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F6B88FC3-8FD3-4A2F-A2F0-BE6E29CB7D4F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020:-:*:*:*:*:*:*:*", "matchCriteriaId": "99F2F851-C18F-4CB8-B47C-516F2AC7955D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020h_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "86AA8980-5D94-4B49-858C-E24290AE8D36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020h:-:*:*:*:*:*:*:*", "matchCriteriaId": "56BAED8B-EEFA-45D7-A5A3-9B62067CE24C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "90674B8F-C4BD-46AF-A86D-A01531074FB6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342030:-:*:*:*:*:*:*:*", "matchCriteriaId": "E472ABB0-5556-4B96-9CEF-2180E24FA7FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1F8EA70F-DD0C-4835-AA65-2B826807756B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302:-:*:*:*:*:*:*:*", "matchCriteriaId": "354968F7-C41B-4C21-8E47-81DC07DF0EA5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302h_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "C3E85D90-A4B8-46B9-B654-84CD68FCF658", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302h:-:*:*:*:*:*:*:*", "matchCriteriaId": "075A16D1-F4DF-4DCB-8DF9-152E282CE01F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030h_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "BBDA1A8F-6AAF-4D09-9DB4-FACAB918963C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342030h:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF9608E7-C9B5-4945-9609-690231DB1B5A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page." }, { "lang": "es", "value": "La inclusi\u00f3n de archivos remotos permite que un atacante manipule una URL espec\u00edfica que referencia al servidor web PLC de Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H o BMXP342030H, de Schneider Electric, el cual, una vez lanzado, resultar\u00e1 en la redirecci\u00f3n del navegador a un archivo remoto mediante un script de Java cargado con la p\u00e1gina web." } ], "id": "CVE-2015-6461", "lastModified": "2024-11-21T02:35:00.673", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 5.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 2.5, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-03-21T19:29:00.267", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-98" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-03-21 19:29
Modified
2024-11-21 02:35
Severity ?
Summary
Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnoc0401_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1769F1F-EAA9-4EE6-9333-A9A4EF4F0F44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnoc0401:-:*:*:*:*:*:*:*", "matchCriteriaId": "DF08654A-FFCB-47D3-AC82-DF7284548962", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnoe0100_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D6712F95-3145-4A61-AF36-F0ECEE961ACD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnoe0100:-:*:*:*:*:*:*:*", "matchCriteriaId": "80FC6FF2-D662-4A57-AAA6-BC04351DC779", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnoe0110_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A6E813C6-D9FF-4BEE-969C-FD3C347AE9AF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnoe0110:-:*:*:*:*:*:*:*", "matchCriteriaId": "98F3B055-8919-4E09-9827-288F0A03DAFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnoe0110h_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "7C19F796-5548-45AA-ACED-25D9E640306E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnoe0110h:-:*:*:*:*:*:*:*", "matchCriteriaId": "1E47DB14-EF4B-4E4E-9DA2-B3F6EFA72BF4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:bmxnor0200h_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1D0B4021-E058-4B5B-823B-BB1C0A939E30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*", "matchCriteriaId": "60D9A366-3394-4275-B884-AE6E7227156E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F6B88FC3-8FD3-4A2F-A2F0-BE6E29CB7D4F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020:-:*:*:*:*:*:*:*", "matchCriteriaId": "99F2F851-C18F-4CB8-B47C-516F2AC7955D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020h_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "86AA8980-5D94-4B49-858C-E24290AE8D36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020h:-:*:*:*:*:*:*:*", "matchCriteriaId": "56BAED8B-EEFA-45D7-A5A3-9B62067CE24C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "90674B8F-C4BD-46AF-A86D-A01531074FB6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342030:-:*:*:*:*:*:*:*", "matchCriteriaId": "E472ABB0-5556-4B96-9CEF-2180E24FA7FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1F8EA70F-DD0C-4835-AA65-2B826807756B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302:-:*:*:*:*:*:*:*", "matchCriteriaId": "354968F7-C41B-4C21-8E47-81DC07DF0EA5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302h_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "C3E85D90-A4B8-46B9-B654-84CD68FCF658", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302h:-:*:*:*:*:*:*:*", "matchCriteriaId": "075A16D1-F4DF-4DCB-8DF9-152E282CE01F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030h_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "BBDA1A8F-6AAF-4D09-9DB4-FACAB918963C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:schneider-electric:modicon_m340_bmxp342030h:-:*:*:*:*:*:*:*", "matchCriteriaId": "EF9608E7-C9B5-4945-9609-690231DB1B5A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser." }, { "lang": "es", "value": "Cross-Site Scripting (XSS) reflejado (no persistente) permite que un atacante manipule una URL espec\u00edfica, que contiene JavaScript que se ejecutar\u00e1 en el navegador del cliente PLC de Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H o BMXP342030H." } ], "id": "CVE-2015-6462", "lastModified": "2024-11-21T02:35:00.833", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 2.3, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-03-21T19:29:00.317", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }