Vulnerabilites related to totolink - a3300r
Vulnerability from fkie_nvd
Published
2024-01-30 15:15
Modified
2024-11-21 08:59
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setPortForwardRules function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setPortForwardRules function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comandos a través del parámetro enable en la función setPortForwardRules.",
      },
   ],
   id: "CVE-2024-24329",
   lastModified: "2024-11-21T08:59:11.217",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2024-01-30T15:15:09.540",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/10/TOTOlink%20A3300R%20setPortForwardRules.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/10/TOTOlink%20A3300R%20setPortForwardRules.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-30 15:15
Modified
2024-11-21 08:59
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the url parameter in the setUrlFilterRules function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the url parameter in the setUrlFilterRules function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comandos a través del parámetro url en la función setUrlFilterRules.",
      },
   ],
   id: "CVE-2024-24332",
   lastModified: "2024-11-21T08:59:11.677",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2024-01-30T15:15:09.693",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/9/TOTOlink%20A3300R%20setUrlFilterRules.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/9/TOTOlink%20A3300R%20setUrlFilterRules.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2023-10-31 14:15
Modified
2024-11-21 08:29
Summary
TOTOLINK A3300R 17.0.0cu.557_B20221024 contains a command injection via the file_name parameter in the UploadFirmwareFile function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R 17.0.0cu.557_B20221024 contains a command injection via the file_name parameter in the UploadFirmwareFile function.",
      },
      {
         lang: "es",
         value: "TOTOLINK A3300R 17.0.0cu.557_B20221024 contiene una inyección de comando a través del parámetro file_name en la función UploadFirmwareFile.",
      },
   ],
   id: "CVE-2023-46976",
   lastModified: "2024-11-21T08:29:34.497",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            type: "Secondary",
         },
      ],
   },
   published: "2023-10-31T14:15:11.697",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/shinypolaris/vuln-reports/blob/master/TOTOLINK%20A3300R/1/README.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/shinypolaris/vuln-reports/blob/master/TOTOLINK%20A3300R/1/README.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-77",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-77",
            },
         ],
         source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
         type: "Secondary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-30 15:15
Modified
2024-11-21 08:59
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setWiFiScheduleCfg function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setWiFiScheduleCfg function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comandos a través del parámetro enable en la función setWiFiScheduleCfg.",
      },
   ],
   id: "CVE-2024-24331",
   lastModified: "2024-11-21T08:59:11.510",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2024-01-30T15:15:09.643",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/13/TOTOlink%20A3300R%20setWiFiScheduleCfg.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/13/TOTOlink%20A3300R%20setWiFiScheduleCfg.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2023-07-07 20:15
Modified
2024-11-21 08:11
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the command parameter in the setTracerouteCfg function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the command parameter in the setTracerouteCfg function.",
      },
   ],
   id: "CVE-2023-37173",
   lastModified: "2024-11-21T08:11:08.143",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2023-07-07T20:15:10.740",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_4",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_4",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-30 15:15
Modified
2024-11-21 08:59
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setParentalRules function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setParentalRules function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comandos a través del parámetro enable en la función setParentalRules.",
      },
   ],
   id: "CVE-2024-24325",
   lastModified: "2024-11-21T08:59:10.503",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2024-01-30T15:15:09.333",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/11/TOTOlink%20A3300R%20setParentalRules.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/11/TOTOlink%20A3300R%20setParentalRules.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-30 15:15
Modified
2024-11-21 08:59
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pppoePass parameter in the setIpv6Cfg function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pppoePass parameter in the setIpv6Cfg function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comandos a través del parámetro pppoePass en la función setIpv6Cfg.",
      },
   ],
   id: "CVE-2024-24327",
   lastModified: "2024-11-21T08:59:10.857",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2024-01-30T15:15:09.430",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/7/TOTOlink%20A3300R%20setIpv6Cfg.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/7/TOTOlink%20A3300R%20setIpv6Cfg.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2023-07-07 20:15
Modified
2024-11-21 08:11
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain an unauthenticated remote code execution (RCE) vulnerability via the lang parameter in the setLanguageCfg function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain an unauthenticated remote code execution (RCE) vulnerability via the lang parameter in the setLanguageCfg function.",
      },
   ],
   id: "CVE-2023-37170",
   lastModified: "2024-11-21T08:11:07.650",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2023-07-07T20:15:10.613",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_1",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_1",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2023-07-07 20:15
Modified
2024-11-21 08:11
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the admuser parameter in the setPasswordCfg function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the admuser parameter in the setPasswordCfg function.",
      },
   ],
   id: "CVE-2023-37171",
   lastModified: "2024-11-21T08:11:07.810",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2023-07-07T20:15:10.660",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_2",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_2",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-11 16:15
Modified
2024-11-21 08:56
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pass parameter in the setTr069Cfg function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pass parameter in the setTr069Cfg function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comando a través del parámetro pass en la función setTr069Cfg.",
      },
   ],
   id: "CVE-2024-23058",
   lastModified: "2024-11-21T08:56:53.007",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            type: "Secondary",
         },
      ],
   },
   published: "2024-01-11T16:15:55.997",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/6/TOTOlink%20A3300R%20setTr069Cfg.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/6/TOTOlink%20A3300R%20setTr069Cfg.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
         type: "Secondary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-11 16:15
Modified
2024-11-21 08:56
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the ip parameter in the setDmzCfg function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the ip parameter in the setDmzCfg function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comandos a través del parámetro ip en la función setDmzCfg.",
      },
   ],
   id: "CVE-2024-23060",
   lastModified: "2024-11-21T08:56:53.390",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2024-01-11T16:15:56.110",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/4/TOTOLINK%20A3300R%20setDmzCfg.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/4/TOTOLINK%20A3300R%20setDmzCfg.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-08-01 00:15
Modified
2024-08-01 17:42
Summary
A vulnerability was found in TOTOLINK A3300R 17.0.0cu.557_B20221024 and classified as critical. Affected by this issue is the function UploadCustomModule of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument File leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-273254 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
cna@vuldb.comhttps://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3300R/UploadCustomModule.mdExploit, Technical Description, Third Party Advisory
cna@vuldb.comhttps://vuldb.com/?ctiid.273254Permissions Required, VDB Entry
cna@vuldb.comhttps://vuldb.com/?id.273254Permissions Required, VDB Entry
cna@vuldb.comhttps://vuldb.com/?submit.378351Third Party Advisory, VDB Entry
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "A vulnerability was found in TOTOLINK A3300R 17.0.0cu.557_B20221024 and classified as critical. Affected by this issue is the function UploadCustomModule of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument File leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-273254 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.",
      },
      {
         lang: "es",
         value: "Una vulnerabilidad fue encontrada en TOTOLINK A3300R 17.0.0cu.557_B20221024 y clasificada como crítica. La función UploadCustomModule del archivo /cgi-bin/cstecgi.cgi es afectada por esta vulnerabilidad. La manipulación del argumento File provoca un desbordamiento dl búfer. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al público y puede utilizarse. VDB-273254 es el identificador asignado a esta vulnerabilidad. NOTA: Se contactó al proveedor tempranamente sobre esta divulgación, pero no respondió de ninguna manera.",
      },
   ],
   id: "CVE-2024-7331",
   lastModified: "2024-08-01T17:42:09.417",
   metrics: {
      cvssMetricV2: [
         {
            acInsufInfo: false,
            baseSeverity: "HIGH",
            cvssData: {
               accessComplexity: "LOW",
               accessVector: "NETWORK",
               authentication: "SINGLE",
               availabilityImpact: "COMPLETE",
               baseScore: 9,
               confidentialityImpact: "COMPLETE",
               integrityImpact: "COMPLETE",
               vectorString: "AV:N/AC:L/Au:S/C:C/I:C/A:C",
               version: "2.0",
            },
            exploitabilityScore: 8,
            impactScore: 10,
            obtainAllPrivilege: false,
            obtainOtherPrivilege: false,
            obtainUserPrivilege: false,
            source: "cna@vuldb.com",
            type: "Secondary",
            userInteractionRequired: false,
         },
      ],
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 8.8,
               baseSeverity: "HIGH",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "LOW",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 2.8,
            impactScore: 5.9,
            source: "cna@vuldb.com",
            type: "Secondary",
         },
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 8.8,
               baseSeverity: "HIGH",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "LOW",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 2.8,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
      cvssMetricV40: [
         {
            cvssData: {
               Automatable: "NOT_DEFINED",
               Recovery: "NOT_DEFINED",
               Safety: "NOT_DEFINED",
               attackComplexity: "LOW",
               attackRequirements: "NONE",
               attackVector: "NETWORK",
               availabilityRequirement: "NOT_DEFINED",
               baseScore: 8.7,
               baseSeverity: "HIGH",
               confidentialityRequirement: "NOT_DEFINED",
               exploitMaturity: "NOT_DEFINED",
               integrityRequirement: "NOT_DEFINED",
               modifiedAttackComplexity: "NOT_DEFINED",
               modifiedAttackRequirements: "NOT_DEFINED",
               modifiedAttackVector: "NOT_DEFINED",
               modifiedPrivilegesRequired: "NOT_DEFINED",
               modifiedSubAvailabilityImpact: "NOT_DEFINED",
               modifiedSubConfidentialityImpact: "NOT_DEFINED",
               modifiedSubIntegrityImpact: "NOT_DEFINED",
               modifiedUserInteraction: "NOT_DEFINED",
               modifiedVulnAvailabilityImpact: "NOT_DEFINED",
               modifiedVulnConfidentialityImpact: "NOT_DEFINED",
               modifiedVulnIntegrityImpact: "NOT_DEFINED",
               privilegesRequired: "LOW",
               providerUrgency: "NOT_DEFINED",
               subAvailabilityImpact: "NONE",
               subConfidentialityImpact: "NONE",
               subIntegrityImpact: "NONE",
               userInteraction: "NONE",
               valueDensity: "NOT_DEFINED",
               vectorString: "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
               version: "4.0",
               vulnAvailabilityImpact: "HIGH",
               vulnConfidentialityImpact: "HIGH",
               vulnIntegrityImpact: "HIGH",
               vulnerabilityResponseEffort: "NOT_DEFINED",
            },
            source: "cna@vuldb.com",
            type: "Secondary",
         },
      ],
   },
   published: "2024-08-01T00:15:02.770",
   references: [
      {
         source: "cna@vuldb.com",
         tags: [
            "Exploit",
            "Technical Description",
            "Third Party Advisory",
         ],
         url: "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3300R/UploadCustomModule.md",
      },
      {
         source: "cna@vuldb.com",
         tags: [
            "Permissions Required",
            "VDB Entry",
         ],
         url: "https://vuldb.com/?ctiid.273254",
      },
      {
         source: "cna@vuldb.com",
         tags: [
            "Permissions Required",
            "VDB Entry",
         ],
         url: "https://vuldb.com/?id.273254",
      },
      {
         source: "cna@vuldb.com",
         tags: [
            "Third Party Advisory",
            "VDB Entry",
         ],
         url: "https://vuldb.com/?submit.378351",
      },
   ],
   sourceIdentifier: "cna@vuldb.com",
   vulnStatus: "Analyzed",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-120",
            },
         ],
         source: "cna@vuldb.com",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2023-05-18 02:15
Modified
2025-01-22 15:15
Summary
TOTOLINK A3300R v17.0.0cu.557 is vulnerable to Command Injection via /cgi-bin/cstecgi.cgi.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557:*:*:*:*:*:*:*",
                     matchCriteriaId: "0C69B7CF-BF5E-423E-ACA1-D46D6BF6D127",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R v17.0.0cu.557 is vulnerable to Command Injection via /cgi-bin/cstecgi.cgi.",
      },
   ],
   id: "CVE-2023-31729",
   lastModified: "2025-01-22T15:15:09.043",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            type: "Secondary",
         },
      ],
   },
   published: "2023-05-18T02:15:12.380",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Product",
         ],
         url: "http://totolink.com",
      },
      {
         source: "cve@mitre.org",
         url: "https://github.com/D2y6p/CVE/blob/2bac2c96e24229fa99e0254eaac1b8809e424b4b/Totolink/CVE-2023-31729/CVE-2023-31729.md",
      },
      {
         source: "cve@mitre.org",
         tags: [
            "Broken Link",
         ],
         url: "https://github.com/D2y6p/CVE/blob/main/Totolink/CVE-2023-31729/CVE-2023-31729.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Product",
         ],
         url: "http://totolink.com",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         url: "https://github.com/D2y6p/CVE/blob/2bac2c96e24229fa99e0254eaac1b8809e424b4b/Totolink/CVE-2023-31729/CVE-2023-31729.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Broken Link",
         ],
         url: "https://github.com/D2y6p/CVE/blob/main/Totolink/CVE-2023-31729/CVE-2023-31729.md",
      },
      {
         source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
         url: "https://github.com/D2y6p/CVE/blob/2bac2c96e24229fa99e0254eaac1b8809e424b4b/Totolink/CVE-2023-31729/CVE-2023-31729.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-77",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-77",
            },
         ],
         source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
         type: "Secondary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2023-10-31 15:15
Modified
2024-11-21 08:29
Summary
In TOTOLINK A3300R V17.0.0cu.557_B20221024 when dealing with setLedCfg request, there is no verification for the enable parameter, which can lead to command injection.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "In TOTOLINK A3300R V17.0.0cu.557_B20221024 when dealing with setLedCfg request, there is no verification for the enable parameter, which can lead to command injection.",
      },
      {
         lang: "es",
         value: "En TOTOLINK A3300R V17.0.0cu.557_B20221024, cuando se trata de la solicitud setLedCfg, no hay verificación para el parámetro enable, lo que puede provocar la inyección de un comando.",
      },
   ],
   id: "CVE-2023-46993",
   lastModified: "2024-11-21T08:29:36.500",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            type: "Secondary",
         },
      ],
   },
   published: "2023-10-31T15:15:09.830",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/AuroraHaaash/vul_report/blob/main/TOTOLINK%20A3300R-Command%20Injection/readme.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/AuroraHaaash/vul_report/blob/main/TOTOLINK%20A3300R-Command%20Injection/readme.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-77",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-77",
            },
         ],
         source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
         type: "Secondary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-30 15:15
Modified
2024-11-21 08:59
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the port or enable parameter in the setRemoteCfg function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the port or enable parameter in the setRemoteCfg function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comando a través de los parámetros port o enable en la función setRemoteCfg.",
      },
   ],
   id: "CVE-2024-24330",
   lastModified: "2024-11-21T08:59:11.363",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2024-01-30T15:15:09.597",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/14/TOTOlink%20A3300R%20setRemoteCfg.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/14/TOTOlink%20A3300R%20setRemoteCfg.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2023-07-07 20:15
Modified
2024-11-21 08:11
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the ip parameter in the setDiagnosisCfg function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the ip parameter in the setDiagnosisCfg function.",
      },
   ],
   id: "CVE-2023-37172",
   lastModified: "2024-11-21T08:11:07.970",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2023-07-07T20:15:10.697",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_3",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_3",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-11 16:15
Modified
2024-11-21 08:56
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the username parameter in the setDdnsCfg function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the username parameter in the setDdnsCfg function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comando a través del parámetro username en la función setDdnsCfg.",
      },
   ],
   id: "CVE-2024-23059",
   lastModified: "2024-11-21T08:56:53.240",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2024-01-11T16:15:56.057",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/2/TOTOlink%20A3300R%20setDdnsCfg.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/2/TOTOlink%20A3300R%20setDdnsCfg.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-30 15:15
Modified
2024-11-21 08:59
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the desc parameter in the setWiFiAclRules function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the desc parameter in the setWiFiAclRules function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comandos a través del parámetro desc en la función setWiFiAclRules.",
      },
   ],
   id: "CVE-2024-24333",
   lastModified: "2024-11-21T08:59:11.823",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2024-01-30T15:15:09.740",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/15/TOTOlink%20A3300R%20setWiFiAclRules.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/15/TOTOlink%20A3300R%20setWiFiAclRules.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-11 16:15
Modified
2024-11-21 08:56
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the tz parameter in the setNtpCfg function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the tz parameter in the setNtpCfg function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comandos a través del parámetro tz en la función setNtpCfg.",
      },
   ],
   id: "CVE-2024-23057",
   lastModified: "2024-11-21T08:56:52.757",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "ADJACENT_NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 8.8,
               baseSeverity: "HIGH",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 2.8,
            impactScore: 5.9,
            source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            type: "Secondary",
         },
      ],
   },
   published: "2024-01-11T16:15:55.943",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/5/TOTOlink%20A3300R%20setNtpCfg.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/5/TOTOlink%20A3300R%20setNtpCfg.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
         type: "Secondary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2023-10-31 15:15
Modified
2024-11-21 08:29
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 is vulnerable to Incorrect Access Control. Attackers are able to reset serveral critical passwords without authentication by visiting specific pages.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 is vulnerable to Incorrect Access Control. Attackers are able to reset serveral critical passwords without authentication by visiting specific pages.",
      },
      {
         lang: "es",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 es vulnerable a un control de acceso incorrecto. Los atacantes pueden restablecer varias contraseñas críticas sin autenticación visitando páginas específicas.",
      },
   ],
   id: "CVE-2023-46992",
   lastModified: "2024-11-21T08:29:36.267",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "NONE",
               baseScore: 7.5,
               baseSeverity: "HIGH",
               confidentialityImpact: "NONE",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 3.6,
            source: "nvd@nist.gov",
            type: "Primary",
         },
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "NONE",
               baseScore: 7.5,
               baseSeverity: "HIGH",
               confidentialityImpact: "NONE",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 3.6,
            source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            type: "Secondary",
         },
      ],
   },
   published: "2023-10-31T15:15:09.787",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/AuroraHaaash/vul_report/blob/main/TOTOLINK%20A3300R/readme.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/AuroraHaaash/vul_report/blob/main/TOTOLINK%20A3300R/readme.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "NVD-CWE-Other",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-863",
            },
         ],
         source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
         type: "Secondary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-11 16:15
Modified
2024-11-21 08:56
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the minute parameter in the setScheduleCfg function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the minute parameter in the setScheduleCfg function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comandos a través del parámetro de minute en la función setScheduleCfg.",
      },
   ],
   id: "CVE-2024-23061",
   lastModified: "2024-11-21T08:56:53.533",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2024-01-11T16:15:56.157",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/3/TOTOLINK%20A3300R%20setScheduleCfg.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/3/TOTOLINK%20A3300R%20setScheduleCfg.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-07-28 10:15
Modified
2024-11-21 09:50
Summary
A vulnerability has been found in TOTOLINK A3300R 17.0.0cu.557_B20221024 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. It is possible to launch the attack on the local host. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The identifier VDB-272569 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "A vulnerability has been found in TOTOLINK A3300R 17.0.0cu.557_B20221024 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. It is possible to launch the attack on the local host. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The identifier VDB-272569 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.",
      },
      {
         lang: "es",
         value: "Una vulnerabilidad ha sido encontrada en TOTOLINK A3300R 17.0.0cu.557_B20221024 y clasificada como problemática. Una función desconocida del archivo /etc/shadow.sample es afectada por esta vulnerabilidad. La manipulación conduce al uso de una contraseña codificada. Es posible lanzar el ataque al servidor local. La complejidad de un ataque es bastante alta. La explotación parece difícil. El exploit ha sido divulgado al público y puede utilizarse. A esta vulnerabilidad se le asignó el identificador VDB-272569. NOTA: Se contactó al proveedor tempranamente sobre esta divulgación, pero no respondió de ninguna manera.",
      },
   ],
   id: "CVE-2024-7155",
   lastModified: "2024-11-21T09:50:57.530",
   metrics: {
      cvssMetricV2: [
         {
            acInsufInfo: false,
            baseSeverity: "LOW",
            cvssData: {
               accessComplexity: "HIGH",
               accessVector: "LOCAL",
               authentication: "SINGLE",
               availabilityImpact: "NONE",
               baseScore: 1,
               confidentialityImpact: "PARTIAL",
               integrityImpact: "NONE",
               vectorString: "AV:L/AC:H/Au:S/C:P/I:N/A:N",
               version: "2.0",
            },
            exploitabilityScore: 1.5,
            impactScore: 2.9,
            obtainAllPrivilege: false,
            obtainOtherPrivilege: false,
            obtainUserPrivilege: false,
            source: "cna@vuldb.com",
            type: "Secondary",
            userInteractionRequired: false,
         },
      ],
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "HIGH",
               attackVector: "LOCAL",
               availabilityImpact: "NONE",
               baseScore: 2.5,
               baseSeverity: "LOW",
               confidentialityImpact: "LOW",
               integrityImpact: "NONE",
               privilegesRequired: "LOW",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N",
               version: "3.1",
            },
            exploitabilityScore: 1,
            impactScore: 1.4,
            source: "cna@vuldb.com",
            type: "Secondary",
         },
         {
            cvssData: {
               attackComplexity: "HIGH",
               attackVector: "LOCAL",
               availabilityImpact: "NONE",
               baseScore: 4.7,
               baseSeverity: "MEDIUM",
               confidentialityImpact: "HIGH",
               integrityImpact: "NONE",
               privilegesRequired: "LOW",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
               version: "3.1",
            },
            exploitabilityScore: 1,
            impactScore: 3.6,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
      cvssMetricV40: [
         {
            cvssData: {
               Automatable: "NOT_DEFINED",
               Recovery: "NOT_DEFINED",
               Safety: "NOT_DEFINED",
               attackComplexity: "HIGH",
               attackRequirements: "NONE",
               attackVector: "LOCAL",
               availabilityRequirement: "NOT_DEFINED",
               baseScore: 2,
               baseSeverity: "LOW",
               confidentialityRequirement: "NOT_DEFINED",
               exploitMaturity: "NOT_DEFINED",
               integrityRequirement: "NOT_DEFINED",
               modifiedAttackComplexity: "NOT_DEFINED",
               modifiedAttackRequirements: "NOT_DEFINED",
               modifiedAttackVector: "NOT_DEFINED",
               modifiedPrivilegesRequired: "NOT_DEFINED",
               modifiedSubAvailabilityImpact: "NOT_DEFINED",
               modifiedSubConfidentialityImpact: "NOT_DEFINED",
               modifiedSubIntegrityImpact: "NOT_DEFINED",
               modifiedUserInteraction: "NOT_DEFINED",
               modifiedVulnAvailabilityImpact: "NOT_DEFINED",
               modifiedVulnConfidentialityImpact: "NOT_DEFINED",
               modifiedVulnIntegrityImpact: "NOT_DEFINED",
               privilegesRequired: "LOW",
               providerUrgency: "NOT_DEFINED",
               subAvailabilityImpact: "NONE",
               subConfidentialityImpact: "NONE",
               subIntegrityImpact: "NONE",
               userInteraction: "NONE",
               valueDensity: "NOT_DEFINED",
               vectorString: "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
               version: "4.0",
               vulnAvailabilityImpact: "NONE",
               vulnConfidentialityImpact: "LOW",
               vulnIntegrityImpact: "NONE",
               vulnerabilityResponseEffort: "NOT_DEFINED",
            },
            source: "cna@vuldb.com",
            type: "Secondary",
         },
      ],
   },
   published: "2024-07-28T10:15:03.053",
   references: [
      {
         source: "cna@vuldb.com",
         tags: [
            "Exploit",
         ],
         url: "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3300R/shadow.md",
      },
      {
         source: "cna@vuldb.com",
         tags: [
            "Permissions Required",
            "Third Party Advisory",
         ],
         url: "https://vuldb.com/?ctiid.272569",
      },
      {
         source: "cna@vuldb.com",
         tags: [
            "Third Party Advisory",
         ],
         url: "https://vuldb.com/?id.272569",
      },
      {
         source: "cna@vuldb.com",
         tags: [
            "Third Party Advisory",
         ],
         url: "https://vuldb.com/?submit.377465",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
         ],
         url: "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3300R/shadow.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Permissions Required",
            "Third Party Advisory",
         ],
         url: "https://vuldb.com/?ctiid.272569",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Third Party Advisory",
         ],
         url: "https://vuldb.com/?id.272569",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Third Party Advisory",
         ],
         url: "https://vuldb.com/?submit.377465",
      },
   ],
   sourceIdentifier: "cna@vuldb.com",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-259",
            },
         ],
         source: "cna@vuldb.com",
         type: "Secondary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-798",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-30 15:15
Modified
2024-11-21 08:59
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the arpEnable parameter in the setStaticDhcpRules function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the arpEnable parameter in the setStaticDhcpRules function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comandos a través del parámetro arpEnable en la función setStaticDhcpRules.",
      },
   ],
   id: "CVE-2024-24326",
   lastModified: "2024-11-21T08:59:10.643",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            type: "Secondary",
         },
      ],
   },
   published: "2024-01-30T15:15:09.380",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/8/TOTOlink%20A3300R%20setStaticDhcpRules.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/8/TOTOlink%20A3300R%20setStaticDhcpRules.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
         type: "Secondary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-11 16:15
Modified
2024-11-21 08:56
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the hostName parameter in the setWanCfg function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the hostName parameter in the setWanCfg function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comandos a través del parámetro hostName en la función setWanCfg.",
      },
   ],
   id: "CVE-2024-22942",
   lastModified: "2024-11-21T08:56:50.037",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2024-01-11T16:15:55.857",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/1/TOTOlink%20A3300R%20setWanCfg.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/1/TOTOlink%20A3300R%20setWanCfg.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2024-01-30 15:15
Modified
2024-11-21 08:59
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setMacFilterRules function.
Impacted products
Vendor Product Version
totolink a3300r_firmware 17.0.0cu.557_b20221024
totolink a3300r -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                     matchCriteriaId: "DD39B647-3419-4C6D-A6A2-30F40822A27D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7F723A73-4B32-4F9E-B5DA-80134D4711C1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setMacFilterRules function.",
      },
      {
         lang: "es",
         value: "Se descubrió que TOTOLINK A3300R V17.0.0cu.557_B20221024 contiene una vulnerabilidad de inyección de comandos a través del parámetro enable en la función setMacFilterRules.",
      },
   ],
   id: "CVE-2024-24328",
   lastModified: "2024-11-21T08:59:10.997",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "ADJACENT_NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 8.8,
               baseSeverity: "HIGH",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 2.8,
            impactScore: 5.9,
            source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            type: "Secondary",
         },
      ],
   },
   published: "2024-01-30T15:15:09.487",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/12/TOTOlink%20A3300R%20setMacFilterRules.md",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Exploit",
            "Third Party Advisory",
         ],
         url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/12/TOTOlink%20A3300R%20setMacFilterRules.md",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-78",
            },
         ],
         source: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
         type: "Secondary",
      },
   ],
}

cve-2024-23057
Vulnerability from cvelistv5
Published
2024-01-11 00:00
Modified
2024-08-30 19:15
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the tz parameter in the setNtpCfg function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T22:51:11.202Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/5/TOTOlink%20A3300R%20setNtpCfg.md",
               },
            ],
            title: "CVE Program Container",
         },
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3300r_firmware",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "17.0.0cu.557_b20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  cvssV3_1: {
                     attackComplexity: "LOW",
                     attackVector: "ADJACENT_NETWORK",
                     availabilityImpact: "HIGH",
                     baseScore: 8.8,
                     baseSeverity: "HIGH",
                     confidentialityImpact: "HIGH",
                     integrityImpact: "HIGH",
                     privilegesRequired: "NONE",
                     scope: "UNCHANGED",
                     userInteraction: "NONE",
                     vectorString: "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                     version: "3.1",
                  },
               },
               {
                  other: {
                     content: {
                        id: "CVE-2024-23057",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-08-30T19:13:33.879600Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            problemTypes: [
               {
                  descriptions: [
                     {
                        cweId: "CWE-78",
                        description: "CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')",
                        lang: "en",
                        type: "CWE",
                     },
                  ],
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-08-30T19:15:07.770Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the tz parameter in the setNtpCfg function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-11T16:00:40.217030",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/5/TOTOlink%20A3300R%20setNtpCfg.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-23057",
      datePublished: "2024-01-11T00:00:00",
      dateReserved: "2024-01-11T00:00:00",
      dateUpdated: "2024-08-30T19:15:07.770Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-23061
Vulnerability from cvelistv5
Published
2024-01-11 00:00
Modified
2024-08-01 22:51
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the minute parameter in the setScheduleCfg function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T22:51:11.293Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/3/TOTOLINK%20A3300R%20setScheduleCfg.md",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the minute parameter in the setScheduleCfg function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-11T16:02:07.961540",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/3/TOTOLINK%20A3300R%20setScheduleCfg.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-23061",
      datePublished: "2024-01-11T00:00:00",
      dateReserved: "2024-01-11T00:00:00",
      dateUpdated: "2024-08-01T22:51:11.293Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-24330
Vulnerability from cvelistv5
Published
2024-01-30 00:00
Modified
2024-08-01 23:19
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the port or enable parameter in the setRemoteCfg function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T23:19:52.502Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/14/TOTOlink%20A3300R%20setRemoteCfg.md",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the port or enable parameter in the setRemoteCfg function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-30T14:44:52.479145",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/14/TOTOlink%20A3300R%20setRemoteCfg.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-24330",
      datePublished: "2024-01-30T00:00:00",
      dateReserved: "2024-01-25T00:00:00",
      dateUpdated: "2024-08-01T23:19:52.502Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-7155
Vulnerability from cvelistv5
Published
2024-07-28 10:00
Modified
2024-08-01 21:52
Summary
A vulnerability has been found in TOTOLINK A3300R 17.0.0cu.557_B20221024 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. It is possible to launch the attack on the local host. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The identifier VDB-272569 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
TOTOLINK A3300R Version: 17.0.0cu.557_B20221024
Create a notification for this product.
Show details on NVD website


{
   containers: {
      adp: [
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3300r",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "17.0.0cu.557_B20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2024-7155",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "partial",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-07-29T14:00:45.836405Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-07-29T14:01:56.724Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T21:52:30.711Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  name: "VDB-272569 | TOTOLINK A3300R shadow.sample hard-coded password",
                  tags: [
                     "vdb-entry",
                     "x_transferred",
                  ],
                  url: "https://vuldb.com/?id.272569",
               },
               {
                  name: "VDB-272569 | CTI Indicators (IOB, IOC, TTP, IOA)",
                  tags: [
                     "signature",
                     "permissions-required",
                     "x_transferred",
                  ],
                  url: "https://vuldb.com/?ctiid.272569",
               },
               {
                  name: "Submit #377465 | TOTOLINK A3300R V17.0.0cu.557_B20221024 Use of Hard-coded Password",
                  tags: [
                     "third-party-advisory",
                     "x_transferred",
                  ],
                  url: "https://vuldb.com/?submit.377465",
               },
               {
                  tags: [
                     "exploit",
                     "x_transferred",
                  ],
                  url: "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3300R/shadow.md",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "A3300R",
               vendor: "TOTOLINK",
               versions: [
                  {
                     status: "affected",
                     version: "17.0.0cu.557_B20221024",
                  },
               ],
            },
         ],
         credits: [
            {
               lang: "en",
               type: "reporter",
               value: "yhryhryhr_tu (VulDB User)",
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been found in TOTOLINK A3300R 17.0.0cu.557_B20221024 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. It is possible to launch the attack on the local host. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The identifier VDB-272569 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.",
            },
            {
               lang: "de",
               value: "In TOTOLINK A3300R 17.0.0cu.557_B20221024 wurde eine Schwachstelle gefunden. Sie wurde als problematisch eingestuft. Hierbei betrifft es unbekannten Programmcode der Datei /etc/shadow.sample. Dank der Manipulation mit unbekannten Daten kann eine use of hard-coded password-Schwachstelle ausgenutzt werden. Der Angriff muss lokal angegangen werden. Die Komplexität eines Angriffs ist eher hoch. Sie gilt als schwierig ausnutzbar. Der Exploit steht zur öffentlichen Verfügung.",
            },
         ],
         metrics: [
            {
               cvssV4_0: {
                  baseScore: 2,
                  baseSeverity: "LOW",
                  vectorString: "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                  version: "4.0",
               },
            },
            {
               cvssV3_1: {
                  baseScore: 2.5,
                  baseSeverity: "LOW",
                  vectorString: "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N",
                  version: "3.1",
               },
            },
            {
               cvssV3_0: {
                  baseScore: 2.5,
                  baseSeverity: "LOW",
                  vectorString: "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N",
                  version: "3.0",
               },
            },
            {
               cvssV2_0: {
                  baseScore: 1,
                  vectorString: "AV:L/AC:H/Au:S/C:P/I:N/A:N",
                  version: "2.0",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-259",
                     description: "CWE-259 Use of Hard-coded Password",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-07-28T10:00:06.076Z",
            orgId: "1af790b2-7ee1-4545-860a-a788eba489b5",
            shortName: "VulDB",
         },
         references: [
            {
               name: "VDB-272569 | TOTOLINK A3300R shadow.sample hard-coded password",
               tags: [
                  "vdb-entry",
               ],
               url: "https://vuldb.com/?id.272569",
            },
            {
               name: "VDB-272569 | CTI Indicators (IOB, IOC, TTP, IOA)",
               tags: [
                  "signature",
                  "permissions-required",
               ],
               url: "https://vuldb.com/?ctiid.272569",
            },
            {
               name: "Submit #377465 | TOTOLINK A3300R V17.0.0cu.557_B20221024 Use of Hard-coded Password",
               tags: [
                  "third-party-advisory",
               ],
               url: "https://vuldb.com/?submit.377465",
            },
            {
               tags: [
                  "exploit",
               ],
               url: "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3300R/shadow.md",
            },
         ],
         timeline: [
            {
               lang: "en",
               time: "2024-07-27T00:00:00.000Z",
               value: "Advisory disclosed",
            },
            {
               lang: "en",
               time: "2024-07-27T02:00:00.000Z",
               value: "VulDB entry created",
            },
            {
               lang: "en",
               time: "2024-07-27T19:32:38.000Z",
               value: "VulDB entry last update",
            },
         ],
         title: "TOTOLINK A3300R shadow.sample hard-coded password",
      },
   },
   cveMetadata: {
      assignerOrgId: "1af790b2-7ee1-4545-860a-a788eba489b5",
      assignerShortName: "VulDB",
      cveId: "CVE-2024-7155",
      datePublished: "2024-07-28T10:00:06.076Z",
      dateReserved: "2024-07-27T17:27:17.368Z",
      dateUpdated: "2024-08-01T21:52:30.711Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2023-37173
Vulnerability from cvelistv5
Published
2023-07-07 00:00
Modified
2024-11-12 19:51
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the command parameter in the setTracerouteCfg function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-02T17:09:32.664Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_4",
               },
            ],
            title: "CVE Program Container",
         },
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:h:totolink:a3000ru:-:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3000ru",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "V17.0.0cu.557_B20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2023-37173",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-11-12T19:50:21.612454Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-11-12T19:51:22.910Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the command parameter in the setTracerouteCfg function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2023-07-07T00:00:00",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_4",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2023-37173",
      datePublished: "2023-07-07T00:00:00",
      dateReserved: "2023-06-28T00:00:00",
      dateUpdated: "2024-11-12T19:51:22.910Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-24332
Vulnerability from cvelistv5
Published
2024-01-30 00:00
Modified
2024-08-01 23:19
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the url parameter in the setUrlFilterRules function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T23:19:52.295Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/9/TOTOlink%20A3300R%20setUrlFilterRules.md",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the url parameter in the setUrlFilterRules function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-30T14:44:53.769795",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/9/TOTOlink%20A3300R%20setUrlFilterRules.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-24332",
      datePublished: "2024-01-30T00:00:00",
      dateReserved: "2024-01-25T00:00:00",
      dateUpdated: "2024-08-01T23:19:52.295Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-23060
Vulnerability from cvelistv5
Published
2024-01-11 00:00
Modified
2024-08-01 22:51
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the ip parameter in the setDmzCfg function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T22:51:11.209Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/4/TOTOLINK%20A3300R%20setDmzCfg.md",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the ip parameter in the setDmzCfg function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-11T15:57:55.671679",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/4/TOTOLINK%20A3300R%20setDmzCfg.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-23060",
      datePublished: "2024-01-11T00:00:00",
      dateReserved: "2024-01-11T00:00:00",
      dateUpdated: "2024-08-01T22:51:11.209Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-7331
Vulnerability from cvelistv5
Published
2024-08-01 00:00
Modified
2024-08-01 14:18
Summary
A vulnerability was found in TOTOLINK A3300R 17.0.0cu.557_B20221024 and classified as critical. Affected by this issue is the function UploadCustomModule of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument File leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-273254 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
TOTOLINK A3300R Version: 17.0.0cu.557_B20221024
Create a notification for this product.
Show details on NVD website


{
   containers: {
      adp: [
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3300r_firmware",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "17.0.0cu.557_b20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2024-7331",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "partial",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-08-01T13:23:49.717773Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-08-01T14:18:14.922Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "A3300R",
               vendor: "TOTOLINK",
               versions: [
                  {
                     status: "affected",
                     version: "17.0.0cu.557_B20221024",
                  },
               ],
            },
         ],
         credits: [
            {
               lang: "en",
               type: "reporter",
               value: "yhryhryhr_miemie (VulDB User)",
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability was found in TOTOLINK A3300R 17.0.0cu.557_B20221024 and classified as critical. Affected by this issue is the function UploadCustomModule of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument File leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-273254 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.",
            },
            {
               lang: "de",
               value: "Eine Schwachstelle wurde in TOTOLINK A3300R 17.0.0cu.557_B20221024 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion UploadCustomModule der Datei /cgi-bin/cstecgi.cgi. Durch die Manipulation des Arguments File mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff über das Netzwerk. Der Exploit steht zur öffentlichen Verfügung.",
            },
         ],
         metrics: [
            {
               cvssV4_0: {
                  baseScore: 8.7,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                  version: "4.0",
               },
            },
            {
               cvssV3_1: {
                  baseScore: 8.8,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            },
            {
               cvssV3_0: {
                  baseScore: 8.8,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.0",
               },
            },
            {
               cvssV2_0: {
                  baseScore: 9,
                  vectorString: "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                  version: "2.0",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-120",
                     description: "CWE-120 Buffer Overflow",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-08-01T00:00:06.525Z",
            orgId: "1af790b2-7ee1-4545-860a-a788eba489b5",
            shortName: "VulDB",
         },
         references: [
            {
               name: "VDB-273254 | TOTOLINK A3300R cstecgi.cgi UploadCustomModule buffer overflow",
               tags: [
                  "vdb-entry",
                  "technical-description",
               ],
               url: "https://vuldb.com/?id.273254",
            },
            {
               name: "VDB-273254 | CTI Indicators (IOB, IOC, IOA)",
               tags: [
                  "signature",
                  "permissions-required",
               ],
               url: "https://vuldb.com/?ctiid.273254",
            },
            {
               name: "Submit #378351 | TOTOLINK A3300R V17.0.0cu.557_B20221024 Buffer Overflow",
               tags: [
                  "third-party-advisory",
               ],
               url: "https://vuldb.com/?submit.378351",
            },
            {
               tags: [
                  "exploit",
               ],
               url: "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3300R/UploadCustomModule.md",
            },
         ],
         timeline: [
            {
               lang: "en",
               time: "2024-07-31T00:00:00.000Z",
               value: "Advisory disclosed",
            },
            {
               lang: "en",
               time: "2024-07-31T02:00:00.000Z",
               value: "VulDB entry created",
            },
            {
               lang: "en",
               time: "2024-07-31T14:35:35.000Z",
               value: "VulDB entry last update",
            },
         ],
         title: "TOTOLINK A3300R cstecgi.cgi UploadCustomModule buffer overflow",
      },
   },
   cveMetadata: {
      assignerOrgId: "1af790b2-7ee1-4545-860a-a788eba489b5",
      assignerShortName: "VulDB",
      cveId: "CVE-2024-7331",
      datePublished: "2024-08-01T00:00:06.525Z",
      dateReserved: "2024-07-31T12:30:07.820Z",
      dateUpdated: "2024-08-01T14:18:14.922Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2023-46976
Vulnerability from cvelistv5
Published
2023-10-31 00:00
Modified
2024-09-06 19:36
Severity ?
Summary
TOTOLINK A3300R 17.0.0cu.557_B20221024 contains a command injection via the file_name parameter in the UploadFirmwareFile function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-02T21:01:22.453Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/shinypolaris/vuln-reports/blob/master/TOTOLINK%20A3300R/1/README.md",
               },
            ],
            title: "CVE Program Container",
         },
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3300r_firmware",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "17.0.0cu.557_b20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  cvssV3_1: {
                     attackComplexity: "LOW",
                     attackVector: "NETWORK",
                     availabilityImpact: "HIGH",
                     baseScore: 9.8,
                     baseSeverity: "CRITICAL",
                     confidentialityImpact: "HIGH",
                     integrityImpact: "HIGH",
                     privilegesRequired: "NONE",
                     scope: "UNCHANGED",
                     userInteraction: "NONE",
                     vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                     version: "3.1",
                  },
               },
               {
                  other: {
                     content: {
                        id: "CVE-2023-46976",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-09-06T19:35:32.646188Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            problemTypes: [
               {
                  descriptions: [
                     {
                        cweId: "CWE-77",
                        description: "CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')",
                        lang: "en",
                        type: "CWE",
                     },
                  ],
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-09-06T19:36:43.025Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R 17.0.0cu.557_B20221024 contains a command injection via the file_name parameter in the UploadFirmwareFile function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2023-10-31T13:43:19.856313",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/shinypolaris/vuln-reports/blob/master/TOTOLINK%20A3300R/1/README.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2023-46976",
      datePublished: "2023-10-31T00:00:00",
      dateReserved: "2023-10-30T00:00:00",
      dateUpdated: "2024-09-06T19:36:43.025Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-22942
Vulnerability from cvelistv5
Published
2024-01-11 00:00
Modified
2024-08-01 22:51
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the hostName parameter in the setWanCfg function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T22:51:11.207Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/1/TOTOlink%20A3300R%20setWanCfg.md",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the hostName parameter in the setWanCfg function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-11T16:05:09.991658",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/1/TOTOlink%20A3300R%20setWanCfg.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-22942",
      datePublished: "2024-01-11T00:00:00",
      dateReserved: "2024-01-11T00:00:00",
      dateUpdated: "2024-08-01T22:51:11.207Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-24333
Vulnerability from cvelistv5
Published
2024-01-30 00:00
Modified
2024-11-12 21:24
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the desc parameter in the setWiFiAclRules function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T23:19:52.465Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/15/TOTOlink%20A3300R%20setWiFiAclRules.md",
               },
            ],
            title: "CVE Program Container",
         },
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2024-24333",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-02-02T16:48:33.699563Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-11-12T21:24:36.937Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the desc parameter in the setWiFiAclRules function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-30T14:44:54.977095",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/15/TOTOlink%20A3300R%20setWiFiAclRules.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-24333",
      datePublished: "2024-01-30T00:00:00",
      dateReserved: "2024-01-25T00:00:00",
      dateUpdated: "2024-11-12T21:24:36.937Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2023-31729
Vulnerability from cvelistv5
Published
2023-05-18 00:00
Modified
2025-01-22 14:54
Severity ?
Summary
TOTOLINK A3300R v17.0.0cu.557 is vulnerable to Command Injection via /cgi-bin/cstecgi.cgi.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-02T14:56:35.539Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "http://totolink.com",
               },
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/D2y6p/CVE/blob/main/Totolink/CVE-2023-31729/CVE-2023-31729.md",
               },
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/D2y6p/CVE/blob/2bac2c96e24229fa99e0254eaac1b8809e424b4b/Totolink/CVE-2023-31729/CVE-2023-31729.md",
               },
            ],
            title: "CVE Program Container",
         },
         {
            metrics: [
               {
                  cvssV3_1: {
                     attackComplexity: "LOW",
                     attackVector: "NETWORK",
                     availabilityImpact: "HIGH",
                     baseScore: 9.8,
                     baseSeverity: "CRITICAL",
                     confidentialityImpact: "HIGH",
                     integrityImpact: "HIGH",
                     privilegesRequired: "NONE",
                     scope: "UNCHANGED",
                     userInteraction: "NONE",
                     vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                     version: "3.1",
                  },
               },
               {
                  other: {
                     content: {
                        id: "CVE-2023-31729",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2025-01-22T14:54:22.056682Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            problemTypes: [
               {
                  descriptions: [
                     {
                        cweId: "CWE-77",
                        description: "CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')",
                        lang: "en",
                        type: "CWE",
                     },
                  ],
               },
            ],
            providerMetadata: {
               dateUpdated: "2025-01-22T14:54:26.895Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            references: [
               {
                  tags: [
                     "exploit",
                  ],
                  url: "https://github.com/D2y6p/CVE/blob/2bac2c96e24229fa99e0254eaac1b8809e424b4b/Totolink/CVE-2023-31729/CVE-2023-31729.md",
               },
            ],
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R v17.0.0cu.557 is vulnerable to Command Injection via /cgi-bin/cstecgi.cgi.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-03-07T19:18:23.150126",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "http://totolink.com",
            },
            {
               url: "https://github.com/D2y6p/CVE/blob/main/Totolink/CVE-2023-31729/CVE-2023-31729.md",
            },
            {
               url: "https://github.com/D2y6p/CVE/blob/2bac2c96e24229fa99e0254eaac1b8809e424b4b/Totolink/CVE-2023-31729/CVE-2023-31729.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2023-31729",
      datePublished: "2023-05-18T00:00:00",
      dateReserved: "2023-04-29T00:00:00",
      dateUpdated: "2025-01-22T14:54:26.895Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-23059
Vulnerability from cvelistv5
Published
2024-01-11 00:00
Modified
2024-08-01 22:51
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the username parameter in the setDdnsCfg function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T22:51:11.307Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/2/TOTOlink%20A3300R%20setDdnsCfg.md",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the username parameter in the setDdnsCfg function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-11T15:59:11.356799",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/2/TOTOlink%20A3300R%20setDdnsCfg.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-23059",
      datePublished: "2024-01-11T00:00:00",
      dateReserved: "2024-01-11T00:00:00",
      dateUpdated: "2024-08-01T22:51:11.307Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-24328
Vulnerability from cvelistv5
Published
2024-01-30 00:00
Modified
2024-08-28 15:22
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setMacFilterRules function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T23:19:52.520Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/12/TOTOlink%20A3300R%20setMacFilterRules.md",
               },
            ],
            title: "CVE Program Container",
         },
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3300r_firmware",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "17.0.0cu.557_b20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  cvssV3_1: {
                     attackComplexity: "LOW",
                     attackVector: "ADJACENT_NETWORK",
                     availabilityImpact: "HIGH",
                     baseScore: 8.8,
                     baseSeverity: "HIGH",
                     confidentialityImpact: "HIGH",
                     integrityImpact: "HIGH",
                     privilegesRequired: "NONE",
                     scope: "UNCHANGED",
                     userInteraction: "NONE",
                     vectorString: "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                     version: "3.1",
                  },
               },
               {
                  other: {
                     content: {
                        id: "CVE-2024-24328",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-02-01T17:05:10.413142Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            problemTypes: [
               {
                  descriptions: [
                     {
                        cweId: "CWE-78",
                        description: "CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')",
                        lang: "en",
                        type: "CWE",
                     },
                  ],
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-08-28T15:22:42.345Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setMacFilterRules function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-30T14:44:51.018648",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/12/TOTOlink%20A3300R%20setMacFilterRules.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-24328",
      datePublished: "2024-01-30T00:00:00",
      dateReserved: "2024-01-25T00:00:00",
      dateUpdated: "2024-08-28T15:22:42.345Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2023-37172
Vulnerability from cvelistv5
Published
2023-07-07 00:00
Modified
2024-11-12 19:52
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the ip parameter in the setDiagnosisCfg function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-02T17:09:32.972Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_3",
               },
            ],
            title: "CVE Program Container",
         },
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:h:totolink:a3000ru:-:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3000ru",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "V17.0.0cu.557_B20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2023-37172",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-11-12T19:52:08.555067Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-11-12T19:52:47.141Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the ip parameter in the setDiagnosisCfg function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2023-07-07T00:00:00",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_3",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2023-37172",
      datePublished: "2023-07-07T00:00:00",
      dateReserved: "2023-06-28T00:00:00",
      dateUpdated: "2024-11-12T19:52:47.141Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2023-46993
Vulnerability from cvelistv5
Published
2023-10-31 00:00
Modified
2024-09-06 19:57
Severity ?
Summary
In TOTOLINK A3300R V17.0.0cu.557_B20221024 when dealing with setLedCfg request, there is no verification for the enable parameter, which can lead to command injection.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-02T21:01:22.184Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/AuroraHaaash/vul_report/blob/main/TOTOLINK%20A3300R-Command%20Injection/readme.md",
               },
            ],
            title: "CVE Program Container",
         },
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3300r_firmware",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "17.0.0cu.557_b20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  cvssV3_1: {
                     attackComplexity: "LOW",
                     attackVector: "NETWORK",
                     availabilityImpact: "HIGH",
                     baseScore: 9.8,
                     baseSeverity: "CRITICAL",
                     confidentialityImpact: "HIGH",
                     integrityImpact: "HIGH",
                     privilegesRequired: "NONE",
                     scope: "UNCHANGED",
                     userInteraction: "NONE",
                     vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                     version: "3.1",
                  },
               },
               {
                  other: {
                     content: {
                        id: "CVE-2023-46993",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-09-06T19:56:21.610101Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            problemTypes: [
               {
                  descriptions: [
                     {
                        cweId: "CWE-77",
                        description: "CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')",
                        lang: "en",
                        type: "CWE",
                     },
                  ],
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-09-06T19:57:52.942Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "In TOTOLINK A3300R V17.0.0cu.557_B20221024 when dealing with setLedCfg request, there is no verification for the enable parameter, which can lead to command injection.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2023-10-31T14:07:04.889574",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/AuroraHaaash/vul_report/blob/main/TOTOLINK%20A3300R-Command%20Injection/readme.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2023-46993",
      datePublished: "2023-10-31T00:00:00",
      dateReserved: "2023-10-30T00:00:00",
      dateUpdated: "2024-09-06T19:57:52.942Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-24329
Vulnerability from cvelistv5
Published
2024-01-30 00:00
Modified
2024-10-18 14:07
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setPortForwardRules function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T23:19:52.141Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/10/TOTOlink%20A3300R%20setPortForwardRules.md",
               },
            ],
            title: "CVE Program Container",
         },
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3300r",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "V17.0.0cu.557_B20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2024-24329",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-01-30T16:46:03.546946Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-10-18T14:07:02.167Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setPortForwardRules function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-30T14:44:51.933658",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/10/TOTOlink%20A3300R%20setPortForwardRules.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-24329",
      datePublished: "2024-01-30T00:00:00",
      dateReserved: "2024-01-25T00:00:00",
      dateUpdated: "2024-10-18T14:07:02.167Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-24327
Vulnerability from cvelistv5
Published
2024-01-30 00:00
Modified
2024-08-01 23:19
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pppoePass parameter in the setIpv6Cfg function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T23:19:52.100Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/7/TOTOlink%20A3300R%20setIpv6Cfg.md",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pppoePass parameter in the setIpv6Cfg function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-30T14:44:50.449797",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/7/TOTOlink%20A3300R%20setIpv6Cfg.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-24327",
      datePublished: "2024-01-30T00:00:00",
      dateReserved: "2024-01-25T00:00:00",
      dateUpdated: "2024-08-01T23:19:52.100Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2023-37170
Vulnerability from cvelistv5
Published
2023-07-07 00:00
Modified
2024-11-12 19:54
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain an unauthenticated remote code execution (RCE) vulnerability via the lang parameter in the setLanguageCfg function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-02T17:09:33.190Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_1",
               },
            ],
            title: "CVE Program Container",
         },
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3300r",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "V17.0.0cu.557_B20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2023-37170",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-11-12T19:54:11.280232Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-11-12T19:54:46.026Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain an unauthenticated remote code execution (RCE) vulnerability via the lang parameter in the setLanguageCfg function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2023-07-07T00:00:00",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_1",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2023-37170",
      datePublished: "2023-07-07T00:00:00",
      dateReserved: "2023-06-28T00:00:00",
      dateUpdated: "2024-11-12T19:54:46.026Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-24326
Vulnerability from cvelistv5
Published
2024-01-30 00:00
Modified
2024-08-29 18:08
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the arpEnable parameter in the setStaticDhcpRules function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T23:19:52.149Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/8/TOTOlink%20A3300R%20setStaticDhcpRules.md",
               },
            ],
            title: "CVE Program Container",
         },
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3300r_firmware",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "17.0.0cu.557_B20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  cvssV3_1: {
                     attackComplexity: "LOW",
                     attackVector: "NETWORK",
                     availabilityImpact: "HIGH",
                     baseScore: 9.8,
                     baseSeverity: "CRITICAL",
                     confidentialityImpact: "HIGH",
                     integrityImpact: "HIGH",
                     privilegesRequired: "NONE",
                     scope: "UNCHANGED",
                     userInteraction: "NONE",
                     vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                     version: "3.1",
                  },
               },
               {
                  other: {
                     content: {
                        id: "CVE-2024-24326",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-02-01T19:21:01.714723Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            problemTypes: [
               {
                  descriptions: [
                     {
                        cweId: "CWE-78",
                        description: "CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')",
                        lang: "en",
                        type: "CWE",
                     },
                  ],
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-08-29T18:08:35.311Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the arpEnable parameter in the setStaticDhcpRules function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-30T14:44:49.854363",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/8/TOTOlink%20A3300R%20setStaticDhcpRules.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-24326",
      datePublished: "2024-01-30T00:00:00",
      dateReserved: "2024-01-25T00:00:00",
      dateUpdated: "2024-08-29T18:08:35.311Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2023-37171
Vulnerability from cvelistv5
Published
2023-07-07 00:00
Modified
2024-11-12 19:53
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the admuser parameter in the setPasswordCfg function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-02T17:09:33.310Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_2",
               },
            ],
            title: "CVE Program Container",
         },
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3300r",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "V17.0.0cu.557_B20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2023-37171",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-11-12T19:53:11.144158Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-11-12T19:53:47.609Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the admuser parameter in the setPasswordCfg function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2023-07-07T00:00:00",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/kafroc/Vuls/tree/main/TOTOLINK/A3300R/cmdi_2",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2023-37171",
      datePublished: "2023-07-07T00:00:00",
      dateReserved: "2023-06-28T00:00:00",
      dateUpdated: "2024-11-12T19:53:47.609Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-24331
Vulnerability from cvelistv5
Published
2024-01-30 00:00
Modified
2024-08-01 23:19
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setWiFiScheduleCfg function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T23:19:52.669Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/13/TOTOlink%20A3300R%20setWiFiScheduleCfg.md",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setWiFiScheduleCfg function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-30T14:44:53.100548",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/13/TOTOlink%20A3300R%20setWiFiScheduleCfg.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-24331",
      datePublished: "2024-01-30T00:00:00",
      dateReserved: "2024-01-25T00:00:00",
      dateUpdated: "2024-08-01T23:19:52.669Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2023-46992
Vulnerability from cvelistv5
Published
2023-10-31 00:00
Modified
2024-10-28 19:06
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 is vulnerable to Incorrect Access Control. Attackers are able to reset serveral critical passwords without authentication by visiting specific pages.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-02T21:01:22.694Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/AuroraHaaash/vul_report/blob/main/TOTOLINK%20A3300R/readme.md",
               },
            ],
            title: "CVE Program Container",
         },
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3300r_firmware",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "17.0.0cu.557_b20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  cvssV3_1: {
                     attackComplexity: "LOW",
                     attackVector: "NETWORK",
                     availabilityImpact: "NONE",
                     baseScore: 7.5,
                     baseSeverity: "HIGH",
                     confidentialityImpact: "NONE",
                     integrityImpact: "HIGH",
                     privilegesRequired: "NONE",
                     scope: "UNCHANGED",
                     userInteraction: "NONE",
                     vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                     version: "3.1",
                  },
               },
               {
                  other: {
                     content: {
                        id: "CVE-2023-46992",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "partial",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-09-06T19:53:59.028905Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            problemTypes: [
               {
                  descriptions: [
                     {
                        cweId: "CWE-863",
                        description: "CWE-863 Incorrect Authorization",
                        lang: "en",
                        type: "CWE",
                     },
                  ],
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-10-28T19:06:24.639Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 is vulnerable to Incorrect Access Control. Attackers are able to reset serveral critical passwords without authentication by visiting specific pages.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2023-10-31T14:02:22.722806",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/AuroraHaaash/vul_report/blob/main/TOTOLINK%20A3300R/readme.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2023-46992",
      datePublished: "2023-10-31T00:00:00",
      dateReserved: "2023-10-30T00:00:00",
      dateUpdated: "2024-10-28T19:06:24.639Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-23058
Vulnerability from cvelistv5
Published
2024-01-11 00:00
Modified
2024-10-01 20:18
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pass parameter in the setTr069Cfg function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T22:51:11.247Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/6/TOTOlink%20A3300R%20setTr069Cfg.md",
               },
            ],
            title: "CVE Program Container",
         },
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "a3300r_firmware",
                  vendor: "totolink",
                  versions: [
                     {
                        status: "affected",
                        version: "17.0.0cu.557_b20221024",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  cvssV3_1: {
                     attackComplexity: "LOW",
                     attackVector: "NETWORK",
                     availabilityImpact: "HIGH",
                     baseScore: 9.8,
                     baseSeverity: "CRITICAL",
                     confidentialityImpact: "HIGH",
                     integrityImpact: "HIGH",
                     privilegesRequired: "NONE",
                     scope: "UNCHANGED",
                     userInteraction: "NONE",
                     vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                     version: "3.1",
                  },
               },
               {
                  other: {
                     content: {
                        id: "CVE-2024-23058",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "yes",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-10-01T20:14:37.533543Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            problemTypes: [
               {
                  descriptions: [
                     {
                        cweId: "CWE-78",
                        description: "CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')",
                        lang: "en",
                        type: "CWE",
                     },
                  ],
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-10-01T20:18:03.993Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pass parameter in the setTr069Cfg function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-11T16:03:21.626235",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/6/TOTOlink%20A3300R%20setTr069Cfg.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-23058",
      datePublished: "2024-01-11T00:00:00",
      dateReserved: "2024-01-11T00:00:00",
      dateUpdated: "2024-10-01T20:18:03.993Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2024-24325
Vulnerability from cvelistv5
Published
2024-01-30 00:00
Modified
2024-08-01 23:19
Severity ?
Summary
TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setParentalRules function.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-01T23:19:52.119Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/11/TOTOlink%20A3300R%20setParentalRules.md",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setParentalRules function.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-01-30T14:44:48.915387",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/11/TOTOlink%20A3300R%20setParentalRules.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-24325",
      datePublished: "2024-01-30T00:00:00",
      dateReserved: "2024-01-25T00:00:00",
      dateUpdated: "2024-08-01T23:19:52.119Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

var-202401-2141
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setPortForwardRules function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202401-2141",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: "a3300r  firmware  17.0.0cu.557 b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r",
            scope: null,
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10467",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002123",
         },
         {
            db: "NVD",
            id: "CVE-2024-24329",
         },
      ],
   },
   cve: "CVE-2024-24329",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2024-10467",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2024-24329",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
               {
                  attackComplexity: "Low",
                  attackVector: "Network",
                  author: "NVD",
                  availabilityImpact: "High",
                  baseScore: 9.8,
                  baseSeverity: "Critical",
                  confidentialityImpact: "High",
                  exploitabilityScore: null,
                  id: "CVE-2024-24329",
                  impactScore: null,
                  integrityImpact: "High",
                  privilegesRequired: "None",
                  scope: "Unchanged",
                  trust: 0.8,
                  userInteraction: "None",
                  vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.0",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2024-24329",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "NVD",
                  id: "CVE-2024-24329",
                  trust: 0.8,
                  value: "Critical",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-10467",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10467",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002123",
         },
         {
            db: "NVD",
            id: "CVE-2024-24329",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setPortForwardRules function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-24329",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002123",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-10467",
         },
      ],
      trust: 2.16,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2024-24329",
            trust: 3.2,
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002123",
            trust: 0.8,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-10467",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10467",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002123",
         },
         {
            db: "NVD",
            id: "CVE-2024-24329",
         },
      ],
   },
   id: "VAR-202401-2141",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10467",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10467",
         },
      ],
   },
   last_update_date: "2024-08-14T15:26:12.909000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for TOTOLINK A3300R setPortForwardRules method command injection vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchInfo/show/527826",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10467",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-78",
            trust: 1,
         },
         {
            problemtype: "OS Command injection (CWE-78) [NVD evaluation ]",
            trust: 0.8,
         },
      ],
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002123",
         },
         {
            db: "NVD",
            id: "CVE-2024-24329",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 2.4,
            url: "https://github.com/funny-mud-peee/iot-vuls/blob/main/totolink%20a3300r/10/totolink%20a3300r%20setportforwardrules.md",
         },
         {
            trust: 0.8,
            url: "https://nvd.nist.gov/vuln/detail/cve-2024-24329",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10467",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002123",
         },
         {
            db: "NVD",
            id: "CVE-2024-24329",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-10467",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002123",
         },
         {
            db: "NVD",
            id: "CVE-2024-24329",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-22T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-10467",
         },
         {
            date: "2024-02-07T00:00:00",
            db: "JVNDB",
            id: "JVNDB-2024-002123",
         },
         {
            date: "2024-01-30T15:15:09.540000",
            db: "NVD",
            id: "CVE-2024-24329",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-28T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-10467",
         },
         {
            date: "2024-02-07T06:50:00",
            db: "JVNDB",
            id: "JVNDB-2024-002123",
         },
         {
            date: "2024-02-01T04:49:18.867000",
            db: "NVD",
            id: "CVE-2024-24329",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK  of  a3300r  in the firmware  OS  Command injection vulnerability",
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002123",
         },
      ],
      trust: 0.8,
   },
}

var-202401-2283
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the desc parameter in the setWiFiAclRules function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202401-2283",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: "a3300r  firmware  17.0.0cu.557 b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r",
            scope: null,
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10468",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002132",
         },
         {
            db: "NVD",
            id: "CVE-2024-24333",
         },
      ],
   },
   cve: "CVE-2024-24333",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2024-10468",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2024-24333",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
               {
                  attackComplexity: "Low",
                  attackVector: "Network",
                  author: "NVD",
                  availabilityImpact: "High",
                  baseScore: 9.8,
                  baseSeverity: "Critical",
                  confidentialityImpact: "High",
                  exploitabilityScore: null,
                  id: "CVE-2024-24333",
                  impactScore: null,
                  integrityImpact: "High",
                  privilegesRequired: "None",
                  scope: "Unchanged",
                  trust: 0.8,
                  userInteraction: "None",
                  vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.0",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2024-24333",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "NVD",
                  id: "CVE-2024-24333",
                  trust: 0.8,
                  value: "Critical",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-10468",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10468",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002132",
         },
         {
            db: "NVD",
            id: "CVE-2024-24333",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the desc parameter in the setWiFiAclRules function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-24333",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002132",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-10468",
         },
      ],
      trust: 2.16,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2024-24333",
            trust: 3.2,
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002132",
            trust: 0.8,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-10468",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10468",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002132",
         },
         {
            db: "NVD",
            id: "CVE-2024-24333",
         },
      ],
   },
   id: "VAR-202401-2283",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10468",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10468",
         },
      ],
   },
   last_update_date: "2024-08-14T15:10:21.793000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for TOTOLINK A3300R setWiFiAclRules method command injection vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchInfo/show/528081",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10468",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-78",
            trust: 1,
         },
         {
            problemtype: "OS Command injection (CWE-78) [NVD evaluation ]",
            trust: 0.8,
         },
      ],
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002132",
         },
         {
            db: "NVD",
            id: "CVE-2024-24333",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 2.4,
            url: "https://github.com/funny-mud-peee/iot-vuls/blob/main/totolink%20a3300r/15/totolink%20a3300r%20setwifiaclrules.md",
         },
         {
            trust: 0.8,
            url: "https://nvd.nist.gov/vuln/detail/cve-2024-24333",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10468",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002132",
         },
         {
            db: "NVD",
            id: "CVE-2024-24333",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-10468",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002132",
         },
         {
            db: "NVD",
            id: "CVE-2024-24333",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-23T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-10468",
         },
         {
            date: "2024-02-07T00:00:00",
            db: "JVNDB",
            id: "JVNDB-2024-002132",
         },
         {
            date: "2024-01-30T15:15:09.740000",
            db: "NVD",
            id: "CVE-2024-24333",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-28T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-10468",
         },
         {
            date: "2024-02-07T06:55:00",
            db: "JVNDB",
            id: "JVNDB-2024-002132",
         },
         {
            date: "2024-02-01T04:50:09.707000",
            db: "NVD",
            id: "CVE-2024-24333",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK  of  a3300r  in the firmware  OS  Command injection vulnerability",
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002132",
         },
      ],
      trust: 0.8,
   },
}

var-202310-1644
Vulnerability from variot

In TOTOLINK A3300R V17.0.0cu.557_B20221024 when dealing with setLedCfg request, there is no verification for the enable parameter, which can lead to command injection. TOTOLINK of a3300r Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company.

There is a command execution vulnerability in the TOTOLINK A3300R V17.0.0cu.557_B20221024 version. An attacker can exploit this vulnerability to potentially cause command injection

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      configurations: {
         "@id": "https://www.variotdbs.pl/ref/configurations",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      exploit_availability: {
         "@id": "https://www.variotdbs.pl/ref/exploit_availability/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202310-1644",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: "a3300r  firmware  17.0.0cu.557 b20221024",
         },
         {
            model: "a3300r",
            scope: null,
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-99183",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015863",
         },
         {
            db: "NVD",
            id: "CVE-2023-46993",
         },
      ],
   },
   cve: "CVE-2023-46993",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2023-99183",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2023-46993",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 2,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
               {
                  attackComplexity: "Low",
                  attackVector: "Network",
                  author: "NVD",
                  availabilityImpact: "High",
                  baseScore: 9.8,
                  baseSeverity: "Critical",
                  confidentialityImpact: "High",
                  exploitabilityScore: null,
                  id: "CVE-2023-46993",
                  impactScore: null,
                  integrityImpact: "High",
                  privilegesRequired: "None",
                  scope: "Unchanged",
                  trust: 0.8,
                  userInteraction: "None",
                  vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.0",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2023-46993",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                  id: "CVE-2023-46993",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "NVD",
                  id: "CVE-2023-46993",
                  trust: 0.8,
                  value: "Critical",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2023-99183",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-99183",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015863",
         },
         {
            db: "NVD",
            id: "CVE-2023-46993",
         },
         {
            db: "NVD",
            id: "CVE-2023-46993",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "In TOTOLINK A3300R V17.0.0cu.557_B20221024 when dealing with setLedCfg request, there is no verification for the enable parameter, which can lead to command injection. TOTOLINK of a3300r Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. \n\r\n\r\nThere is a command execution vulnerability in the TOTOLINK A3300R V17.0.0cu.557_B20221024 version. An attacker can exploit this vulnerability to potentially cause command injection",
      sources: [
         {
            db: "NVD",
            id: "CVE-2023-46993",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015863",
         },
         {
            db: "CNVD",
            id: "CNVD-2023-99183",
         },
         {
            db: "VULMON",
            id: "CVE-2023-46993",
         },
      ],
      trust: 2.25,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2023-46993",
            trust: 3.3,
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015863",
            trust: 0.8,
         },
         {
            db: "CNVD",
            id: "CNVD-2023-99183",
            trust: 0.6,
         },
         {
            db: "VULMON",
            id: "CVE-2023-46993",
            trust: 0.1,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-99183",
         },
         {
            db: "VULMON",
            id: "CVE-2023-46993",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015863",
         },
         {
            db: "NVD",
            id: "CVE-2023-46993",
         },
      ],
   },
   id: "VAR-202310-1644",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-99183",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-99183",
         },
      ],
   },
   last_update_date: "2024-09-07T23:22:57.870000Z",
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-77",
            trust: 1,
         },
         {
            problemtype: "Command injection (CWE-77) [NVD evaluation ]",
            trust: 0.8,
         },
      ],
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2023-015863",
         },
         {
            db: "NVD",
            id: "CVE-2023-46993",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 1.9,
            url: "https://github.com/aurorahaaash/vul_report/blob/main/totolink%20a3300r-command%20injection/readme.md",
         },
         {
            trust: 1.4,
            url: "https://nvd.nist.gov/vuln/detail/cve-2023-46993",
         },
         {
            trust: 0.1,
            url: "https://nvd.nist.gov",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-99183",
         },
         {
            db: "VULMON",
            id: "CVE-2023-46993",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015863",
         },
         {
            db: "NVD",
            id: "CVE-2023-46993",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2023-99183",
         },
         {
            db: "VULMON",
            id: "CVE-2023-46993",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015863",
         },
         {
            db: "NVD",
            id: "CVE-2023-46993",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2023-12-13T00:00:00",
            db: "CNVD",
            id: "CNVD-2023-99183",
         },
         {
            date: "2023-10-31T00:00:00",
            db: "VULMON",
            id: "CVE-2023-46993",
         },
         {
            date: "2023-12-28T00:00:00",
            db: "JVNDB",
            id: "JVNDB-2023-015863",
         },
         {
            date: "2023-10-31T15:15:09.830000",
            db: "NVD",
            id: "CVE-2023-46993",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2023-12-21T00:00:00",
            db: "CNVD",
            id: "CNVD-2023-99183",
         },
         {
            date: "2023-10-31T00:00:00",
            db: "VULMON",
            id: "CVE-2023-46993",
         },
         {
            date: "2023-12-28T05:00:00",
            db: "JVNDB",
            id: "JVNDB-2023-015863",
         },
         {
            date: "2024-09-06T20:35:14.960000",
            db: "NVD",
            id: "CVE-2023-46993",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK  of  a3300r  Command injection vulnerability in firmware",
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2023-015863",
         },
      ],
      trust: 0.8,
   },
}

var-202401-2083
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setWiFiScheduleCfg function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202401-2083",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: "a3300r  firmware  17.0.0cu.557 b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r",
            scope: null,
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09296",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002125",
         },
         {
            db: "NVD",
            id: "CVE-2024-24331",
         },
      ],
   },
   cve: "CVE-2024-24331",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2024-09296",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2024-24331",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
               {
                  attackComplexity: "Low",
                  attackVector: "Network",
                  author: "NVD",
                  availabilityImpact: "High",
                  baseScore: 9.8,
                  baseSeverity: "Critical",
                  confidentialityImpact: "High",
                  exploitabilityScore: null,
                  id: "CVE-2024-24331",
                  impactScore: null,
                  integrityImpact: "High",
                  privilegesRequired: "None",
                  scope: "Unchanged",
                  trust: 0.8,
                  userInteraction: "None",
                  vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.0",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2024-24331",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "NVD",
                  id: "CVE-2024-24331",
                  trust: 0.8,
                  value: "Critical",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-09296",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09296",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002125",
         },
         {
            db: "NVD",
            id: "CVE-2024-24331",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setWiFiScheduleCfg function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-24331",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002125",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-09296",
         },
      ],
      trust: 2.16,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2024-24331",
            trust: 3.2,
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002125",
            trust: 0.8,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-09296",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09296",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002125",
         },
         {
            db: "NVD",
            id: "CVE-2024-24331",
         },
      ],
   },
   id: "VAR-202401-2083",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09296",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09296",
         },
      ],
   },
   last_update_date: "2024-08-14T15:05:14.187000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for TOTOLINK A3300R setWiFiScheduleCfg method command injection vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchInfo/show/525936",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09296",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-78",
            trust: 1,
         },
         {
            problemtype: "OS Command injection (CWE-78) [NVD evaluation ]",
            trust: 0.8,
         },
      ],
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002125",
         },
         {
            db: "NVD",
            id: "CVE-2024-24331",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 1.8,
            url: "https://github.com/funny-mud-peee/iot-vuls/blob/main/totolink%20a3300r/13/totolink%20a3300r%20setwifischedulecfg.md",
         },
         {
            trust: 1.4,
            url: "https://nvd.nist.gov/vuln/detail/cve-2024-24331",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09296",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002125",
         },
         {
            db: "NVD",
            id: "CVE-2024-24331",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-09296",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002125",
         },
         {
            db: "NVD",
            id: "CVE-2024-24331",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-07T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-09296",
         },
         {
            date: "2024-02-07T00:00:00",
            db: "JVNDB",
            id: "JVNDB-2024-002125",
         },
         {
            date: "2024-01-30T15:15:09.643000",
            db: "NVD",
            id: "CVE-2024-24331",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-21T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-09296",
         },
         {
            date: "2024-02-07T06:52:00",
            db: "JVNDB",
            id: "JVNDB-2024-002125",
         },
         {
            date: "2024-02-01T04:18:45.817000",
            db: "NVD",
            id: "CVE-2024-24331",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK  of  a3300r  in the firmware  OS  Command injection vulnerability",
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002125",
         },
      ],
      trust: 0.8,
   },
}

var-202310-1550
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 is vulnerable to Incorrect Access Control. Attackers are able to reset serveral critical passwords without authentication by visiting specific pages. TOTOLINK of a3300r There are unspecified vulnerabilities in the firmware.Information may be tampered with. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      configurations: {
         "@id": "https://www.variotdbs.pl/ref/configurations",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      exploit_availability: {
         "@id": "https://www.variotdbs.pl/ref/exploit_availability/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202310-1550",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: "a3300r  firmware  17.0.0cu.557 b20221024",
         },
         {
            model: "a3300r",
            scope: null,
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-99330",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015864",
         },
         {
            db: "NVD",
            id: "CVE-2023-46992",
         },
      ],
   },
   cve: "CVE-2023-46992",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "NONE",
                  baseScore: 7.8,
                  confidentialityImpact: "NONE",
                  exploitabilityScore: 10,
                  id: "CNVD-2023-99330",
                  impactScore: 6.9,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:N/I:C/A:N",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "NONE",
                  baseScore: 7.5,
                  baseSeverity: "HIGH",
                  confidentialityImpact: "NONE",
                  exploitabilityScore: 3.9,
                  id: "CVE-2023-46992",
                  impactScore: 3.6,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 2,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                  version: "3.1",
               },
               {
                  attackComplexity: "Low",
                  attackVector: "Network",
                  author: "NVD",
                  availabilityImpact: "None",
                  baseScore: 7.5,
                  baseSeverity: "High",
                  confidentialityImpact: "None",
                  exploitabilityScore: null,
                  id: "CVE-2023-46992",
                  impactScore: null,
                  integrityImpact: "High",
                  privilegesRequired: "None",
                  scope: "Unchanged",
                  trust: 0.8,
                  userInteraction: "None",
                  vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                  version: "3.0",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2023-46992",
                  trust: 1,
                  value: "HIGH",
               },
               {
                  author: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                  id: "CVE-2023-46992",
                  trust: 1,
                  value: "HIGH",
               },
               {
                  author: "NVD",
                  id: "CVE-2023-46992",
                  trust: 0.8,
                  value: "High",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2023-99330",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-99330",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015864",
         },
         {
            db: "NVD",
            id: "CVE-2023-46992",
         },
         {
            db: "NVD",
            id: "CVE-2023-46992",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 is vulnerable to Incorrect Access Control. Attackers are able to reset serveral critical passwords without authentication by visiting specific pages. TOTOLINK of a3300r There are unspecified vulnerabilities in the firmware.Information may be tampered with. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company",
      sources: [
         {
            db: "NVD",
            id: "CVE-2023-46992",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015864",
         },
         {
            db: "CNVD",
            id: "CNVD-2023-99330",
         },
         {
            db: "VULMON",
            id: "CVE-2023-46992",
         },
      ],
      trust: 2.25,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2023-46992",
            trust: 3.3,
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015864",
            trust: 0.8,
         },
         {
            db: "CNVD",
            id: "CNVD-2023-99330",
            trust: 0.6,
         },
         {
            db: "VULMON",
            id: "CVE-2023-46992",
            trust: 0.1,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-99330",
         },
         {
            db: "VULMON",
            id: "CVE-2023-46992",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015864",
         },
         {
            db: "NVD",
            id: "CVE-2023-46992",
         },
      ],
   },
   id: "VAR-202310-1550",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-99330",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-99330",
         },
      ],
   },
   last_update_date: "2024-10-29T23:41:43.798000Z",
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "NVD-CWE-Other",
            trust: 1,
         },
         {
            problemtype: "CWE-863",
            trust: 1,
         },
         {
            problemtype: "others (CWE-Other) [NVD evaluation ]",
            trust: 0.8,
         },
      ],
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2023-015864",
         },
         {
            db: "NVD",
            id: "CVE-2023-46992",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 1.9,
            url: "https://github.com/aurorahaaash/vul_report/blob/main/totolink%20a3300r/readme.md",
         },
         {
            trust: 1.4,
            url: "https://nvd.nist.gov/vuln/detail/cve-2023-46992",
         },
         {
            trust: 0.1,
            url: "https://nvd.nist.gov",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-99330",
         },
         {
            db: "VULMON",
            id: "CVE-2023-46992",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015864",
         },
         {
            db: "NVD",
            id: "CVE-2023-46992",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2023-99330",
         },
         {
            db: "VULMON",
            id: "CVE-2023-46992",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2023-015864",
         },
         {
            db: "NVD",
            id: "CVE-2023-46992",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2023-12-13T00:00:00",
            db: "CNVD",
            id: "CNVD-2023-99330",
         },
         {
            date: "2023-10-31T00:00:00",
            db: "VULMON",
            id: "CVE-2023-46992",
         },
         {
            date: "2023-12-28T00:00:00",
            db: "JVNDB",
            id: "JVNDB-2023-015864",
         },
         {
            date: "2023-10-31T15:15:09.787000",
            db: "NVD",
            id: "CVE-2023-46992",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2023-12-21T00:00:00",
            db: "CNVD",
            id: "CNVD-2023-99330",
         },
         {
            date: "2023-10-31T00:00:00",
            db: "VULMON",
            id: "CVE-2023-46992",
         },
         {
            date: "2023-12-28T05:00:00",
            db: "JVNDB",
            id: "JVNDB-2023-015864",
         },
         {
            date: "2024-10-28T19:35:10.917000",
            db: "NVD",
            id: "CVE-2023-46992",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK  of  a3300r  Firmware vulnerabilities",
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2023-015864",
         },
      ],
      trust: 0.8,
   },
}

var-202401-2084
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setParentalRules function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      exploit_availability: {
         "@id": "https://www.variotdbs.pl/ref/exploit_availability/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202401-2084",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: "a3300r  firmware  17.0.0cu.557 b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r",
            scope: null,
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10466",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002118",
         },
         {
            db: "NVD",
            id: "CVE-2024-24325",
         },
      ],
   },
   cve: "CVE-2024-24325",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2024-10466",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2024-24325",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
               {
                  attackComplexity: "Low",
                  attackVector: "Network",
                  author: "NVD",
                  availabilityImpact: "High",
                  baseScore: 9.8,
                  baseSeverity: "Critical",
                  confidentialityImpact: "High",
                  exploitabilityScore: null,
                  id: "CVE-2024-24325",
                  impactScore: null,
                  integrityImpact: "High",
                  privilegesRequired: "None",
                  scope: "Unchanged",
                  trust: 0.8,
                  userInteraction: "None",
                  vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.0",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2024-24325",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "NVD",
                  id: "CVE-2024-24325",
                  trust: 0.8,
                  value: "Critical",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-10466",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10466",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002118",
         },
         {
            db: "NVD",
            id: "CVE-2024-24325",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setParentalRules function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-24325",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002118",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-10466",
         },
      ],
      trust: 2.16,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2024-24325",
            trust: 3.2,
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002118",
            trust: 0.8,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-10466",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10466",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002118",
         },
         {
            db: "NVD",
            id: "CVE-2024-24325",
         },
      ],
   },
   id: "VAR-202401-2084",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10466",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10466",
         },
      ],
   },
   last_update_date: "2024-08-14T14:01:22.686000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for TOTOLINK A3300R setParentalRules method command injection vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchInfo/show/527821",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10466",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-78",
            trust: 1,
         },
         {
            problemtype: "OS Command injection (CWE-78) [NVD evaluation ]",
            trust: 0.8,
         },
      ],
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002118",
         },
         {
            db: "NVD",
            id: "CVE-2024-24325",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 1.8,
            url: "https://github.com/funny-mud-peee/iot-vuls/blob/main/totolink%20a3300r/11/totolink%20a3300r%20setparentalrules.md",
         },
         {
            trust: 1.4,
            url: "https://nvd.nist.gov/vuln/detail/cve-2024-24325",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10466",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002118",
         },
         {
            db: "NVD",
            id: "CVE-2024-24325",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-10466",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002118",
         },
         {
            db: "NVD",
            id: "CVE-2024-24325",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-22T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-10466",
         },
         {
            date: "2024-02-07T00:00:00",
            db: "JVNDB",
            id: "JVNDB-2024-002118",
         },
         {
            date: "2024-01-30T15:15:09.333000",
            db: "NVD",
            id: "CVE-2024-24325",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-28T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-10466",
         },
         {
            date: "2024-02-07T06:45:00",
            db: "JVNDB",
            id: "JVNDB-2024-002118",
         },
         {
            date: "2024-02-01T04:49:27.410000",
            db: "NVD",
            id: "CVE-2024-24325",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK  of  a3300r  in the firmware  OS  Command injection vulnerability",
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002118",
         },
      ],
      trust: 0.8,
   },
}

var-202401-1561
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pass parameter in the setTr069Cfg function. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      configurations: {
         "@id": "https://www.variotdbs.pl/ref/configurations",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      exploit_availability: {
         "@id": "https://www.variotdbs.pl/ref/exploit_availability/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1561",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06222",
         },
         {
            db: "NVD",
            id: "CVE-2024-23058",
         },
      ],
   },
   cve: "CVE-2024-23058",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2024-06222",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2024-23058",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 2,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2024-23058",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                  id: "CVE-2024-23058",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-06222",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06222",
         },
         {
            db: "NVD",
            id: "CVE-2024-23058",
         },
         {
            db: "NVD",
            id: "CVE-2024-23058",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pass parameter in the setTr069Cfg function. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-23058",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-06222",
         },
      ],
      trust: 1.44,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2024-23058",
            trust: 1.6,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-06222",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06222",
         },
         {
            db: "NVD",
            id: "CVE-2024-23058",
         },
      ],
   },
   id: "VAR-202401-1561",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06222",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06222",
         },
      ],
   },
   last_update_date: "2024-10-02T23:14:16.690000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for TOTOLINK A3300R setTr069Cfg method command injection vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchInfo/show/517926",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06222",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-78",
            trust: 1,
         },
      ],
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-23058",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 1.6,
            url: "https://github.com/funny-mud-peee/iot-vuls/blob/main/totolink%20a3300r/6/totolink%20a3300r%20settr069cfg.md",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06222",
         },
         {
            db: "NVD",
            id: "CVE-2024-23058",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-06222",
         },
         {
            db: "NVD",
            id: "CVE-2024-23058",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-01-19T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-06222",
         },
         {
            date: "2024-01-11T16:15:55.997000",
            db: "NVD",
            id: "CVE-2024-23058",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-01-29T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-06222",
         },
         {
            date: "2024-10-01T21:35:06.453000",
            db: "NVD",
            id: "CVE-2024-23058",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R setTr069Cfg method command injection vulnerability",
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06222",
         },
      ],
      trust: 0.6,
   },
}

var-202401-1392
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the minute parameter in the setScheduleCfg function. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      exploit_availability: {
         "@id": "https://www.variotdbs.pl/ref/exploit_availability/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1392",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06221",
         },
         {
            db: "NVD",
            id: "CVE-2024-23061",
         },
      ],
   },
   cve: "CVE-2024-23061",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2024-06221",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2024-23061",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2024-23061",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-06221",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06221",
         },
         {
            db: "NVD",
            id: "CVE-2024-23061",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the minute parameter in the setScheduleCfg function. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-23061",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-06221",
         },
      ],
      trust: 1.44,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2024-23061",
            trust: 1.6,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-06221",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06221",
         },
         {
            db: "NVD",
            id: "CVE-2024-23061",
         },
      ],
   },
   id: "VAR-202401-1392",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06221",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06221",
         },
      ],
   },
   last_update_date: "2024-08-14T14:59:53.493000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for TOTOLINK A3300R setScheduleCfg method command injection vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchInfo/show/517921",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06221",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-78",
            trust: 1,
         },
      ],
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-23061",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 1.6,
            url: "https://github.com/funny-mud-peee/iot-vuls/blob/main/totolink%20a3300r/3/totolink%20a3300r%20setschedulecfg.md",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06221",
         },
         {
            db: "NVD",
            id: "CVE-2024-23061",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-06221",
         },
         {
            db: "NVD",
            id: "CVE-2024-23061",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-01-19T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-06221",
         },
         {
            date: "2024-01-11T16:15:56.157000",
            db: "NVD",
            id: "CVE-2024-23061",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-01-29T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-06221",
         },
         {
            date: "2024-01-18T15:18:14.357000",
            db: "NVD",
            id: "CVE-2024-23061",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R setScheduleCfg method command injection vulnerability",
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06221",
         },
      ],
      trust: 0.6,
   },
}

var-202401-1391
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the hostName parameter in the setWanCfg function. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1391",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06223",
         },
         {
            db: "NVD",
            id: "CVE-2024-22942",
         },
      ],
   },
   cve: "CVE-2024-22942",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2024-06223",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2024-22942",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2024-22942",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-06223",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06223",
         },
         {
            db: "NVD",
            id: "CVE-2024-22942",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the hostName parameter in the setWanCfg function. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-22942",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-06223",
         },
      ],
      trust: 1.44,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2024-22942",
            trust: 1.6,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-06223",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06223",
         },
         {
            db: "NVD",
            id: "CVE-2024-22942",
         },
      ],
   },
   id: "VAR-202401-1391",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06223",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06223",
         },
      ],
   },
   last_update_date: "2024-08-14T13:19:29.588000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for TOTOLINK A3300R setWanCfg method command injection vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchInfo/show/517901",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06223",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-78",
            trust: 1,
         },
      ],
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-22942",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 1,
            url: "https://github.com/funny-mud-peee/iot-vuls/blob/main/totolink%20a3300r/1/totolink%20a3300r%20setwancfg.md",
         },
         {
            trust: 0.6,
            url: "https://nvd.nist.gov/vuln/detail/cve-2024-22942",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06223",
         },
         {
            db: "NVD",
            id: "CVE-2024-22942",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-06223",
         },
         {
            db: "NVD",
            id: "CVE-2024-22942",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-01-19T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-06223",
         },
         {
            date: "2024-01-11T16:15:55.857000",
            db: "NVD",
            id: "CVE-2024-22942",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-01-29T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-06223",
         },
         {
            date: "2024-01-18T15:15:47.273000",
            db: "NVD",
            id: "CVE-2024-22942",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R setWanCfg method command injection vulnerability",
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06223",
         },
      ],
      trust: 0.6,
   },
}

var-202401-2215
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pppoePass parameter in the setIpv6Cfg function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. This vulnerability is caused by the pppoePass parameter of the setIpv6Cfg method failing to correctly filter special characters, commands, etc. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202401-2215",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: "a3300r  firmware  17.0.0cu.557 b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r",
            scope: null,
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   cve: "CVE-2024-24327",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2024-09295",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2024-24327",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
               {
                  attackComplexity: "Low",
                  attackVector: "Network",
                  author: "NVD",
                  availabilityImpact: "High",
                  baseScore: 9.8,
                  baseSeverity: "Critical",
                  confidentialityImpact: "High",
                  exploitabilityScore: null,
                  id: "CVE-2024-24327",
                  impactScore: null,
                  integrityImpact: "High",
                  privilegesRequired: "None",
                  scope: "Unchanged",
                  trust: 0.8,
                  userInteraction: "None",
                  vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.0",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2024-24327",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "NVD",
                  id: "CVE-2024-24327",
                  trust: 0.8,
                  value: "Critical",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-09295",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pppoePass parameter in the setIpv6Cfg function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. This vulnerability is caused by the pppoePass parameter of the setIpv6Cfg method failing to correctly filter special characters, commands, etc. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
      ],
      trust: 2.16,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2024-24327",
            trust: 3.2,
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
            trust: 0.8,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   id: "VAR-202401-2215",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
      ],
   },
   last_update_date: "2024-08-14T14:42:48.189000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for TOTOLINK A3300R setIpv6Cfg method command injection vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchInfo/show/526031",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-78",
            trust: 1,
         },
         {
            problemtype: "OS Command injection (CWE-78) [NVD evaluation ]",
            trust: 0.8,
         },
      ],
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 2.4,
            url: "https://github.com/funny-mud-peee/iot-vuls/blob/main/totolink%20a3300r/7/totolink%20a3300r%20setipv6cfg.md",
         },
         {
            trust: 0.8,
            url: "https://nvd.nist.gov/vuln/detail/cve-2024-24327",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-08T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            date: "2024-02-07T00:00:00",
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            date: "2024-01-30T15:15:09.430000",
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-21T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            date: "2024-02-07T06:48:00",
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            date: "2024-02-01T04:49:22.830000",
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK  of  a3300r  in the firmware  OS  Command injection vulnerability",
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
      ],
      trust: 0.8,
   },
}

var-202401-1378
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the username parameter in the setDdnsCfg function. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      exploit_availability: {
         "@id": "https://www.variotdbs.pl/ref/exploit_availability/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1378",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06218",
         },
         {
            db: "NVD",
            id: "CVE-2024-23059",
         },
      ],
   },
   cve: "CVE-2024-23059",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2024-06218",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2024-23059",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2024-23059",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-06218",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06218",
         },
         {
            db: "NVD",
            id: "CVE-2024-23059",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the username parameter in the setDdnsCfg function. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-23059",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-06218",
         },
      ],
      trust: 1.44,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2024-23059",
            trust: 1.6,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-06218",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06218",
         },
         {
            db: "NVD",
            id: "CVE-2024-23059",
         },
      ],
   },
   id: "VAR-202401-1378",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06218",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06218",
         },
      ],
   },
   last_update_date: "2024-08-14T15:41:25.181000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for TOTOLINK A3300R setDdnsCfg method command injection vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchInfo/show/517906",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06218",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-78",
            trust: 1,
         },
      ],
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-23059",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 1.6,
            url: "https://github.com/funny-mud-peee/iot-vuls/blob/main/totolink%20a3300r/2/totolink%20a3300r%20setddnscfg.md",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06218",
         },
         {
            db: "NVD",
            id: "CVE-2024-23059",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-06218",
         },
         {
            db: "NVD",
            id: "CVE-2024-23059",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-01-19T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-06218",
         },
         {
            date: "2024-01-11T16:15:56.057000",
            db: "NVD",
            id: "CVE-2024-23059",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-01-29T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-06218",
         },
         {
            date: "2024-01-18T15:17:14.453000",
            db: "NVD",
            id: "CVE-2024-23059",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R setDdnsCfg method command injection vulnerability",
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06218",
         },
      ],
      trust: 0.6,
   },
}

var-202305-1882
Vulnerability from variot

TOTOLINK A3300R v17.0.0cu.557 is vulnerable to Command Injection via /cgi-bin/cstecgi.cgi. TOTOLINK A3300R is a wireless router produced by TOTOLINK in China. The vulnerability comes from the fact that the setddnscfg function of requesting /cgi-bin/cstecgi.cgi fails to properly filter special characters, commands, etc. in constructing commands. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202305-1882",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557",
         },
         {
            model: "a3300r v17.0.0cu.557",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-41866",
         },
         {
            db: "NVD",
            id: "CVE-2023-31729",
         },
      ],
   },
   cve: "CVE-2023-31729",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2023-41866",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2023-31729",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2023-31729",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2023-41866",
                  trust: 0.6,
                  value: "HIGH",
               },
               {
                  author: "CNNVD",
                  id: "CNNVD-202305-1754",
                  trust: 0.6,
                  value: "CRITICAL",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-41866",
         },
         {
            db: "CNNVD",
            id: "CNNVD-202305-1754",
         },
         {
            db: "NVD",
            id: "CVE-2023-31729",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R v17.0.0cu.557 is vulnerable to Command Injection via /cgi-bin/cstecgi.cgi. TOTOLINK A3300R is a wireless router produced by TOTOLINK in China. The vulnerability comes from the fact that the setddnscfg function of requesting /cgi-bin/cstecgi.cgi fails to properly filter special characters, commands, etc. in constructing commands. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2023-31729",
         },
         {
            db: "CNVD",
            id: "CNVD-2023-41866",
         },
         {
            db: "VULMON",
            id: "CVE-2023-31729",
         },
      ],
      trust: 1.53,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2023-31729",
            trust: 2.3,
         },
         {
            db: "CNVD",
            id: "CNVD-2023-41866",
            trust: 0.6,
         },
         {
            db: "CNNVD",
            id: "CNNVD-202305-1754",
            trust: 0.6,
         },
         {
            db: "VULMON",
            id: "CVE-2023-31729",
            trust: 0.1,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-41866",
         },
         {
            db: "VULMON",
            id: "CVE-2023-31729",
         },
         {
            db: "CNNVD",
            id: "CNNVD-202305-1754",
         },
         {
            db: "NVD",
            id: "CVE-2023-31729",
         },
      ],
   },
   id: "VAR-202305-1882",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-41866",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-41866",
         },
      ],
   },
   last_update_date: "2024-08-14T15:05:42.070000Z",
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-77",
            trust: 1,
         },
      ],
      sources: [
         {
            db: "NVD",
            id: "CVE-2023-31729",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 2.3,
            url: "https://github.com/d2y6p/cve/blob/main/totolink/cve-2023-31729/cve-2023-31729.md",
         },
         {
            trust: 1.7,
            url: "http://totolink.com",
         },
         {
            trust: 1,
            url: "https://github.com/d2y6p/cve/blob/2bac2c96e24229fa99e0254eaac1b8809e424b4b/totolink/cve-2023-31729/cve-2023-31729.md",
         },
         {
            trust: 0.6,
            url: "https://cxsecurity.com/cveshow/cve-2023-31729/",
         },
         {
            trust: 0.1,
            url: "https://nvd.nist.gov",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-41866",
         },
         {
            db: "VULMON",
            id: "CVE-2023-31729",
         },
         {
            db: "CNNVD",
            id: "CNNVD-202305-1754",
         },
         {
            db: "NVD",
            id: "CVE-2023-31729",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2023-41866",
         },
         {
            db: "VULMON",
            id: "CVE-2023-31729",
         },
         {
            db: "CNNVD",
            id: "CNNVD-202305-1754",
         },
         {
            db: "NVD",
            id: "CVE-2023-31729",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2023-05-26T00:00:00",
            db: "CNVD",
            id: "CNVD-2023-41866",
         },
         {
            date: "2023-05-18T00:00:00",
            db: "VULMON",
            id: "CVE-2023-31729",
         },
         {
            date: "2023-05-18T00:00:00",
            db: "CNNVD",
            id: "CNNVD-202305-1754",
         },
         {
            date: "2023-05-18T02:15:12.380000",
            db: "NVD",
            id: "CVE-2023-31729",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2023-05-26T00:00:00",
            db: "CNVD",
            id: "CNVD-2023-41866",
         },
         {
            date: "2023-05-18T00:00:00",
            db: "VULMON",
            id: "CVE-2023-31729",
         },
         {
            date: "2023-05-26T00:00:00",
            db: "CNNVD",
            id: "CNNVD-202305-1754",
         },
         {
            date: "2024-03-07T20:15:49.907000",
            db: "NVD",
            id: "CVE-2023-31729",
         },
      ],
   },
   threat_type: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "remote",
      sources: [
         {
            db: "CNNVD",
            id: "CNNVD-202305-1754",
         },
      ],
      trust: 0.6,
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R Command Injection Vulnerability",
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2023-41866",
         },
         {
            db: "CNNVD",
            id: "CNNVD-202305-1754",
         },
      ],
      trust: 1.2,
   },
   type: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/type#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "command injection",
      sources: [
         {
            db: "CNNVD",
            id: "CNNVD-202305-1754",
         },
      ],
      trust: 0.6,
   },
}

var-202401-1393
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the ip parameter in the setDmzCfg function. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      exploit_availability: {
         "@id": "https://www.variotdbs.pl/ref/exploit_availability/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1393",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06219",
         },
         {
            db: "NVD",
            id: "CVE-2024-23060",
         },
      ],
   },
   cve: "CVE-2024-23060",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2024-06219",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2024-23060",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2024-23060",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-06219",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06219",
         },
         {
            db: "NVD",
            id: "CVE-2024-23060",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the ip parameter in the setDmzCfg function. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-23060",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-06219",
         },
      ],
      trust: 1.44,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2024-23060",
            trust: 1.6,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-06219",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06219",
         },
         {
            db: "NVD",
            id: "CVE-2024-23060",
         },
      ],
   },
   id: "VAR-202401-1393",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06219",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06219",
         },
      ],
   },
   last_update_date: "2024-08-14T14:23:36.754000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for TOTOLINK A3300R setDmzCfg method command injection vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchInfo/show/517911",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06219",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-78",
            trust: 1,
         },
      ],
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-23060",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 1,
            url: "https://github.com/funny-mud-peee/iot-vuls/blob/main/totolink%20a3300r/4/totolink%20a3300r%20setdmzcfg.md",
         },
         {
            trust: 0.6,
            url: "https://nvd.nist.gov/vuln/detail/cve-2024-23060",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06219",
         },
         {
            db: "NVD",
            id: "CVE-2024-23060",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-06219",
         },
         {
            db: "NVD",
            id: "CVE-2024-23060",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-01-19T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-06219",
         },
         {
            date: "2024-01-11T16:15:56.110000",
            db: "NVD",
            id: "CVE-2024-23060",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-01-29T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-06219",
         },
         {
            date: "2024-01-18T15:17:35.587000",
            db: "NVD",
            id: "CVE-2024-23060",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R setDmzCfg method command injection vulnerability",
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06219",
         },
      ],
      trust: 0.6,
   },
}

var-202401-2259
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setMacFilterRules function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      configurations: {
         "@id": "https://www.variotdbs.pl/ref/configurations",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      exploit_availability: {
         "@id": "https://www.variotdbs.pl/ref/exploit_availability/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202401-2259",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: "a3300r  firmware  17.0.0cu.557 b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r",
            scope: null,
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10465",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002122",
         },
         {
            db: "NVD",
            id: "CVE-2024-24328",
         },
      ],
   },
   cve: "CVE-2024-24328",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2024-10465",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2024-24328",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
               {
                  attackComplexity: "LOW",
                  attackVector: "ADJACENT",
                  author: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                  availabilityImpact: "HIGH",
                  baseScore: 8.8,
                  baseSeverity: "HIGH",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 2.8,
                  id: "CVE-2024-24328",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
               {
                  attackComplexity: "Low",
                  attackVector: "Network",
                  author: "NVD",
                  availabilityImpact: "High",
                  baseScore: 9.8,
                  baseSeverity: "Critical",
                  confidentialityImpact: "High",
                  exploitabilityScore: null,
                  id: "CVE-2024-24328",
                  impactScore: null,
                  integrityImpact: "High",
                  privilegesRequired: "None",
                  scope: "Unchanged",
                  trust: 0.8,
                  userInteraction: "None",
                  vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.0",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2024-24328",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                  id: "CVE-2024-24328",
                  trust: 1,
                  value: "HIGH",
               },
               {
                  author: "NVD",
                  id: "CVE-2024-24328",
                  trust: 0.8,
                  value: "Critical",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-10465",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10465",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002122",
         },
         {
            db: "NVD",
            id: "CVE-2024-24328",
         },
         {
            db: "NVD",
            id: "CVE-2024-24328",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the enable parameter in the setMacFilterRules function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-24328",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002122",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-10465",
         },
      ],
      trust: 2.16,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2024-24328",
            trust: 3.2,
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002122",
            trust: 0.8,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-10465",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10465",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002122",
         },
         {
            db: "NVD",
            id: "CVE-2024-24328",
         },
      ],
   },
   id: "VAR-202401-2259",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10465",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10465",
         },
      ],
   },
   last_update_date: "2024-08-29T23:12:58.380000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for TOTOLINK A3300R setMacFilterRules method command injection vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchInfo/show/527816",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10465",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-78",
            trust: 1,
         },
         {
            problemtype: "OS Command injection (CWE-78) [NVD evaluation ]",
            trust: 0.8,
         },
      ],
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002122",
         },
         {
            db: "NVD",
            id: "CVE-2024-24328",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 2.4,
            url: "https://github.com/funny-mud-peee/iot-vuls/blob/main/totolink%20a3300r/12/totolink%20a3300r%20setmacfilterrules.md",
         },
         {
            trust: 0.8,
            url: "https://nvd.nist.gov/vuln/detail/cve-2024-24328",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-10465",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002122",
         },
         {
            db: "NVD",
            id: "CVE-2024-24328",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-10465",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002122",
         },
         {
            db: "NVD",
            id: "CVE-2024-24328",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-22T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-10465",
         },
         {
            date: "2024-02-07T00:00:00",
            db: "JVNDB",
            id: "JVNDB-2024-002122",
         },
         {
            date: "2024-01-30T15:15:09.487000",
            db: "NVD",
            id: "CVE-2024-24328",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-28T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-10465",
         },
         {
            date: "2024-02-07T06:49:00",
            db: "JVNDB",
            id: "JVNDB-2024-002122",
         },
         {
            date: "2024-08-28T16:35:12.420000",
            db: "NVD",
            id: "CVE-2024-24328",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK  of  a3300r  in the firmware  OS  Command injection vulnerability",
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002122",
         },
      ],
      trust: 0.8,
   },
}

var-202401-1367
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the tz parameter in the setNtpCfg function. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      configurations: {
         "@id": "https://www.variotdbs.pl/ref/configurations",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      exploit_availability: {
         "@id": "https://www.variotdbs.pl/ref/exploit_availability/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202401-1367",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06220",
         },
         {
            db: "NVD",
            id: "CVE-2024-23057",
         },
      ],
   },
   cve: "CVE-2024-23057",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2024-06220",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2024-23057",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
               {
                  attackComplexity: "LOW",
                  attackVector: "ADJACENT",
                  author: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                  availabilityImpact: "HIGH",
                  baseScore: 8.8,
                  baseSeverity: "HIGH",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 2.8,
                  id: "CVE-2024-23057",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2024-23057",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                  id: "CVE-2024-23057",
                  trust: 1,
                  value: "HIGH",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-06220",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06220",
         },
         {
            db: "NVD",
            id: "CVE-2024-23057",
         },
         {
            db: "NVD",
            id: "CVE-2024-23057",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the tz parameter in the setNtpCfg function. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-23057",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-06220",
         },
      ],
      trust: 1.44,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2024-23057",
            trust: 1.6,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-06220",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06220",
         },
         {
            db: "NVD",
            id: "CVE-2024-23057",
         },
      ],
   },
   id: "VAR-202401-1367",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06220",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06220",
         },
      ],
   },
   last_update_date: "2024-08-31T22:57:44.412000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for TOTOLINK A3300R setNtpCfg method command injection vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchInfo/show/517916",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06220",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-78",
            trust: 1,
         },
      ],
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-23057",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 1.6,
            url: "https://github.com/funny-mud-peee/iot-vuls/blob/main/totolink%20a3300r/5/totolink%20a3300r%20setntpcfg.md",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06220",
         },
         {
            db: "NVD",
            id: "CVE-2024-23057",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-06220",
         },
         {
            db: "NVD",
            id: "CVE-2024-23057",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-01-19T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-06220",
         },
         {
            date: "2024-01-11T16:15:55.943000",
            db: "NVD",
            id: "CVE-2024-23057",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-01-29T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-06220",
         },
         {
            date: "2024-08-30T20:35:09.487000",
            db: "NVD",
            id: "CVE-2024-23057",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R setNtpCfg method command injection vulnerability",
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-06220",
         },
      ],
      trust: 0.6,
   },
}